Wacom Co RY24TL RF Module User Manual

Wacom Co Ltd RF Module

User manual

1            User manual  Wireless module   RY24TL-01DT  Rev 1.0  Ryoyo Electro Corporation
2  Compliance statement to FCC/IC   This module complies with part 15 of the FCC rules and IC RSS-210. Operation  is  subject  to  the  following  conditions:  (1)  This  device  may  not  cause  harmful interference,  and  (2)  this  device  must  accept  any  interference  received,  including interference that may cause undesired operation.    Warning Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  RF exposure compliance   1) To comply with FCC/IC RF exposure compliance requirements, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. 2)  This  transmitter  must  not  be  co-located  or  operating  in  conjunction  with  any  other antenna or transmitter.   Requirements to end product    This module must be integrated only by OEM integrators under the following conditions.  (1) OEM integrator has to be aware not provide information to the users regarding how to install or remove this module in the users manual of the end product which integrate this module. Installation by end users is strictly prohibited.  (2) Antenna   OEM integrator shall use this module without any modifications including antenna.   If module  integrator uses a unique antenna, the  FCC certification  is required for the end product.  OEM  integrator  must  make  sure  that  20cm  minimum  separation  is  maintained between users and the antenna.  (3) Co-location.   This module must not be co-located or operated in conjunction with any other antenna or transmitter.  The  module  integrator  shall  obtain  FCC  approval  for  the  end  product,  if  the module is used for co-location operation.
3  (4) Markings   To satisfy FCC/IC exterior labeling requirements, the following text must be placed on the exterior of the end product.    Contains Module FCC ID: HV4RY24TL, IC: 6888A-RY24TL Any similar wording that expresses the same meaning may be used.    (5) Caution to user for modification The following caution is expressed on the user’s instruction manual.   The changes or  modifications not expressly approved by the  party responsible for compliance could void the user’s authority to operate the device.    (6) Compliance statement to FCC The following statement is expressed on the user’s instruction manual.   NOTE: This equipment has been tested and found to comply with the limits for a Class  B  digital  device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are designed  to  provide  reasonable  protection  against  harmful  interference  in  a residential  installation.    This  equipment  generates  uses  and  can  radiate  radio frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If  this  equipment  does  cause  harmful  interference  to  radio  or  television reception,  which  can  be  determined by  turning  the  equipment  off  and on,  the user  is  encouraged  to  try  to  correct  the  interference  by  one  or  more  of  the following measures:  —Reorient or relocate the receiving antenna.  —Increase the separation between the equipment and receiver.  —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  —Consult the dealer or an experienced radio/TV technician for help.    (7) Compliance statement to IC The following statement is expressed on the user’s instruction manual.   Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
4   Table of contents 1. Introduction .........................................................................................................................5 2. RF Specification ...................................................................................................................5 3. Connecter description ..........................................................................................................6 4. Control specification ............................................................................................................7 4.1 Requirements for power on procedure ..........................................................................7 4.2 Reset ..............................................................................................................................7 4.3 Operation mode selection ..............................................................................................7 4.4 User ID write/read .........................................................................................................7 4.5 Serial communication (UART) ........................................................................................8 4.6 Out detect function ........................................................................................................9 4.7 Stand-by mode ...............................................................................................................9 5. Electrical characteristics .................................................................................................... 10 5.1 Absolute maximum ratings ......................................................................................... 10 5.2 Recommended operating conditions (DC) .................................................................. 10 5.3 Recommended operating conditions (AC and others) ................................................ 10 6. Mechanical specification .................................................................................................... 11
5  1. Introduction Wireless module RY24TL-01DT is bi-directional serial data communication module by using 2.4GHz ISM band.  Features Ultra low latency 2.4GHz wireless serial communication   Secure wireless communication by 40bit ID code   Unique user ID (24bit)   RF strength monitor  2. RF Specification  Item Description RF band 2.4GHz ISM band Carrier frequency 2,404MHz/2,409MHz/2,414MHz/2,437MHz 2,442MHz/2,447MHz/2,470MHz/2,475MHz 2,480MHz Band width 1MHz Output power + 1.8 dBm (1.5mW) Receive sensitivity - 85 dBm (0.1%BER) Modulation GFSK Diffusion No Data transfer rate 1Mbps Antenna type PCB antenna ID length 40bit
6  3. Connecter description Pin No Pin name Direction Internal connection Description 1 VDD In - VDD in (+3.3V) 2 3 RESET In Pull up (4.7Kohm) Reset 4 MODE In/Out Pull up (4.7Kohm) Only for F/W update 5 TXD In Pull up (68Kohm) Data input (UART) 6 RXD Out Pull up (68Kohm) Data output (UART) 7 Out Detect/ ID OK Out Pull down (68Kohm) Out detect and ID set finish indicator 8 BS/PS In Pull down (68Kohm) Mode select (Low=PS/High=BS) 9 ID_0 In Pull down (68Kohm) ID set mode 0 select 10 ID_1 In Pull down (68Kohm) ID set mode 1 select 11 VSS In - VSS 12  Pin layout
7  4. Control specification 4.1 Requirements for power on procedure CPU I/F will available to access with command 150ms after power supply had stabled. BS/PS pin have to be fixed before not passed 120ms after power supply had stabled. When BS mode is selected, this module starts a sequence for searching the other BS module. After the searching sequence, a table of used is decided. (Max 6 tables)  4.2 Reset For reset module, input low pulse to RESET pin Low. After reset, It is necessary to keep time condition same as after power on.    4.3 Operation mode selection Operation mode is decided as follow. <BS/PS pin> Low/Open    : PS Mode           High                : BS Mode  4.4 User ID write/read User can rewrite ID by using ID_0, ID_1 and serial pin. <ID1 / ID0> 0 0     : Normal 0 1     : Not specified 1 0     : ID write 1 1     : ID read
8  4.5 Serial communication (UART) This module provide serial interface for control as follow.                 Kind of Packet Input/Output Length (byte) Valid mode (BS/PS) BS→PS payload input In 8 BS PS→BS payload output Out 16 BS PS→BS payload input In 16 PS BS→PS payload output Out 8 PS ID write In 3 BS/PS ID read Out 3 BS/PS Test command In 5 BS/PS     Item Value Bit rate 115,200bps Data length 8bit Parity Non Start bit 1bit Stop bit 1bit Flow control Non
9  4.6 Out detect function User can detect that this system is out of range by using Out Detect pin.   <Out Detect pin>       Low  : Out of range                 High      : Good quality for communication  4.7 Stand-by mode By using serial command, user can disable to transmit from BS module. When into stand-by mode, all packets except broadcast packet are canceled to transmit.
10  5. Electrical characteristics 5.1 Absolute maximum ratings Symbol Parameter Rating Unit VDD Supply voltage -0.3 to 3.6 V VSS Supply voltage -0.3 to VDD+0.3 V Topr Operating temperature -20 to 85 ℃  5.2 Recommended operating conditions (DC) Symbol Parameter Conditions Min Typ Max Unit VDD Supply voltage  3.0 3.3 3.6 V Topr Operating temperature  0  60 ℃ VIH H input voltage  VDD*0.8  VDD V VIL L input voltage  0  VDD*0.2 V VOH H output voltage IOH = -1mA VDD-0.5  VDD V VOL L output voltage IOL = 1mA   0.5 V IOH H output current Average of 100ms   -5 mA IOL L output current Average of 100ms 5   mA IVDD1 Power supply current (BS mode) Standard: 25℃ Max:0 to 60℃ 10.5  25 mA IVDD2 Power supply current (PS mode) Standard: 25℃ Max:0 to 60℃ 18  30 mA Note) Temperature condition is 0 to 60℃, if not specified.  5.3 Recommended operating conditions (AC and others) Symbol Parameter Conditions Min Typ Max Unit - UART output   baud rate  113.8 115.2 117.3 Kbps - ID write cycles MCU manufacturer guaranteed cycle 1000   Cycle - ID retention Temp.    55℃ 20   Year
11  6. Mechanical specification Outline drawing (unit mm)     Weight: 8.2g  Height with connecter Height of PCB Maximum height without connector 4.4