6-Jul-2004     Page 1 of 1  Radio Frequency Radiation Exposure Evaluation for GigAccess Self Install GA_900_RSU  1. RF Hazard Distance Calculation Limit for power density for general population /uncontrolled exposure is  0.604 mW/cm² (for 902MHz) The Power density is given by:  P (mW/cm²)= PT /4π R² Therefore:  R = Distance to the center of radiation antenna [cm] (3)  mWdBm PP log10×=   Therefore:         (4  1010 dBmPmWP= The hazard distances versus antenna gain are listed in Table  1-1.  Note!        GigAccess™ 900 was designed for fixed and mobile applications.    point-to-multi-point operation Antenna  Gain  Tx Power  Safe Distance  Sector Type [dBi]  [Numeric]  [dBm]  [mW]  [cm]   6 3.98 30 1000  22.6  p2mp Table  1-1: Hazard Distance versus Antenna Gain for Point to Multi Point  When using the system for point to multi point (p2mp) applications all outdoor units must be installed with a separation distance of at least 30 cm from all persons during normal operation. 