WaveMark Procedure No. 99-0030
Rev. C
6-Channel Multiplexer
P/N 03-0004
Assembly and Configuration
Procedure
WaveMark, Inc. - Proprietary and Confidential
Notice of FCC Compliance
Note: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
Changes or modifications not expressly approved by WaveMark, Inc. could void the
user’s authority to operate the equipment.
FCC Limited Modular Approval applies only to cabinets that have been expressly
approved. Alternate configurations not listed below must be tested.
Limited Modular Approval UQY-HF1000A applies to: HF1000, HFH1000, HFS1000
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause
undesired operation.
This product must be professionally activated by WaveMark trained personnel and must
only be serviced by WaveMark trained service personnel.
Notice of Industrie Canada Compliance
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
99-0030 Rev. C
Page 2 of 21
WaveMark, Inc. - Proprietary and Confidential
Document Revision History
Rev.
Notes/Changes
Date
First Release – ECO-0065
11 Aug 2008
Add label and notes for FCC Limited Modular Approval
6 Nov 2008
Added additional FCC notice
5 Dec 2008
99-0030 Rev. C
Page 3 of 21
WaveMark, Inc. - Proprietary and Confidential
Table of Contents
1.
Scope ...................................................................................................................... 5
2.
Safety ...................................................................................................................... 5
3.
Assembling the Mux/Reader Assembly - P/N 04-0008 ........................................ 6
Pick List..................................................................................................................................................... 6
Tools and Test Equipment Required ........................................................................................................ 6
Programming ............................................................................................................................................ 7
Assembly ................................................................................................................................................ 10
Configuration........................................................................................................................................... 15
Testing .................................................................................................................................................... 18
Labeling .................................................................................................................................................. 19
4.
Assembling the Mux RF to Data Assembly - P/N 03-0004 ................................ 20
Pick List................................................................................................................................................... 20
Tools and Test Equipment Required ...................................................................................................... 20
Assembly ................................................................................................................................................ 20
Testing .................................................................................................................................................... 21
Labeling .................................................................................................................................................. 21
99-0030 Rev. C
Page 4 of 21
WaveMark, Inc. - Proprietary and Confidential
1.
Scope
This procedure provides all the information needed to assemble and configure the
6-Channel Multiplexer (Mux) P/N 03-0004.
2.
Safety
Before you pickup one tool you need to be committed to build safely. If needed, secure
a set of safety glasses as well as gloves and use them. Be sure the area selected for
build is free of clutter and adequate space is available.
It is your responsibility and an integral part of your job to work safely! If you are
unfamiliar with some of the tools you need to use in assembly or the build procedures
are unclear, ask for assistance!
99-0030 Rev. C
Page 5 of 21
WaveMark, Inc. - Proprietary and Confidential
3.
Assembling the Mux/Reader Assembly - P/N 04-0008
Pick List
To assemble, pick the following part number/quantities from inventory. When
building more than one, scale the values accordingly.
Qty
P/N
Part Name
04-0011
Assembled/Tested Mux Board
_____
91-0028
Label, Feig Reader
_____
38-0006
Cable, SMA/M strait to SMA/M
right angle
_____
53-0003
Mux Mounting Plate
_____
80-0008
Screw, Ss, 8-32 x ¼, socket head
_____
80-0011
Screw, nylon 4-40 x ¼ in. slotted
pan head
_____
83-0002
Standoff, nylon 4-40 x 7/16 in.
dual F threaded
_____
83-0003
Jack Screw, 0.312 with hardware
_____
86-0012
Rubber Foot, 0.406 high
_____
90-0002
RFID Reader, Feig Serial
) _____
38-0011
Cable, RDR to PCB 2” Long
_____
38-0004
4 Pin Power cable
Tools and Test Equipment Required
Bondhaus Gorilla Grip fold up Allen wrench set 0.050 to
3/16
Portable Voltmeter
Wire cutters, small
Tiny flat head
screwdriver
99-0030 Rev. C
Page 6 of 21
WaveMark, Inc. - Proprietary and Confidential
Nut drivers: 3/16, 1/4, 5/16, 11/32
PC with serial port
and OBID Software
Provided
Flat head screwdriver, medium
Serial cable
ICD-U40 Unit Kit
Mux Power Supply
Blue Dot Mux hex file located on the svn in this location:
Feig Reader
Software
…DOCS_SVN\Engineering\Hardware\Firmware\Mux_040011\Blue_Dot
Note: If this is not an in-house installation, the following procedures are required before
the start of programming.
1. Download the software provided with the ICD-U40 Unit kit.
2. Download the OBID software provided with the FIEG reader.
Programming
3.1
When the Mux boards arrive if there is no “color dot” on the boards’
microprocessors, located at U1 (25-0001 IC) then they will need to be
programmed.
3.2
To program the Mux Boards you must select a PC that has the ICD-U40
programming software installed. Plug the USB based ICD-U40
programmer into one of the PC’s unused USB ports.
3.3
Plug the programming adapter cable into the programming connector on
the Mux Board located at J3
3.4
Connect the Mux Board 12Vdc power supply to the Mux Board location
L20. There is a power LED which will light when power is applied.
3.5
Download the Hex file from the docs SVN in this location
…DOCS_SVN\Engineering\Hardware\Firmware\Mux_04-0011\Blue_Dot
and save to your Desktop.
3.5
99-0030 Rev. C
Click on the ICD icon to open the programming application, and it will
automatically connect to the programmer. If the programmer is
Page 7 of 21
WaveMark, Inc. - Proprietary and Confidential
recognized by the software then the main program screen will be
displayed; see the graphic below.
99-0030 Rev. C
Page 8 of 21
WaveMark, Inc. - Proprietary and Confidential
3.6
Select the file to be downloaded by clicking on the down arrow located
to the right of the “Download to Target” button. When you click on this
you will be given a list of the most recently downloaded files as well as a
Browse button. Use these to navigate to the file location and select the
blue-dot mux file; see the graphic below.
3.7
As soon as the file to download has been selected the application will
immediately start programming the target device. A dialog box will pop
up if programming fails.
3.8
When successful programming is completed place a blue dot on the
microprocessor (16F877, large square chip) Location U1 p/n 25-0001
IC.
99-0030 Rev. C
Page 9 of 21
WaveMark, Inc. - Proprietary and Confidential
Assembly
3.9
Select one Assembled/Tested/Programmed Mux Board (04-0011).
Select one D-Sub (38-0011). Solder the pre-stripped ends into the
corresponding locations on the Mux board using color code as followed;
pin 2 (red) pin 3 (white) pin 5 (black) pin 7 (blue) pin 9 (purple) at
reference designator J8.
3.10
Select four of the 4-40 nylon standoffs (83-0002) and eight of the 4-40
nylon screws (80-0011). Select the RFID Reader (90-0002) and mount
the RFID Reader to the Mux Board using this hardware, with the 9-pin
serial connector on the RFID reader located at X2 aligned near the
corresponding 9-pin short cable assembly on the Mux board (J8).
Apply label 91-0028 approximately as shown in the figure below over
depopulated BNC connector number 8.
99-0030 Rev. C
Page 10 of 21
WaveMark, Inc. - Proprietary and Confidential
Label
placement
91-0028
3.11
99-0030 Rev. C
The RFID Reader is shipped with a package of small jumpers. Place
one jumper on J4 and discard balance. See the picture below.
Page 11 of 21
WaveMark, Inc. - Proprietary and Confidential
3.12
Select one SMA Strait to Right Angle Cable (38-0006) and attach the
right angled end to the SMA connector on the RFID Reader and the
straight end to the SMA connector on the Mux Board located at J16.
3.14
Remove Kapton Tape from 8-position DIP Switch located at SW1
3.15
On the 8-position DIP switch on the Mux board, set the switches so
switch number 3 is OFF and all other switches are ON.
99-0030 Rev. C
Page 12 of 21
WaveMark, Inc. - Proprietary and Confidential
3.16
Select the three rubber feet (86-0012). Place the feet on the underside
of the Mux Board (side that faces the Mounting Plate) located between
BNC connectors 2/4, 4/6 and 6/8. Be sure not to interfere with soldered
pins when placing them.
3.17
Select the Mux Mounting Plate (53-0003) and secure the Mux to the
Mux Mounting Plate with six of the 8/32 x ¼ socket head screws
(80-0008) placed at the corners of the board at the middle of the left and
right edges. Each screw mounts into an insert that’s built into the Mux
Mounting Plate.
99-0030 Rev. C
Page 13 of 21
WaveMark, Inc. - Proprietary and Confidential
Note: The end of the Mux that has the reader should be facing the end
of the Mux Mounting Plate that has the two slits on either side.
3.18
99-0030 Rev. C
Select the Jack Screws with hardware (83-0003) and attach two sets of
hardware for each of the board mounted 9-pin D-sub connectors located
at J7 & J2. Each Jack Screw should have two washers placed on the
threaded end before the threaded end is screwed into place.
Page 14 of 21
WaveMark, Inc. - Proprietary and Confidential
Configuration
3.19
Be sure no other FIEG readers are connected to the PC.
3.20
Connect the Mux 4-pin power cable (38-0004) located at J4 to a DCP;
this will power up the Mux.
ZZ21
Identify a PC with a serial port available and the OBID software
installed. Connect a serial cable between the PC and the Reader port
on the Mux Located at J7.
3.22
Start OBID software from the ID ISOStart icon.
99-0030 Rev. C
Page 15 of 21
WaveMark, Inc. - Proprietary and Confidential
3.23
The reader should be auto detected by the software; to move forward
select the Feig reader. Only one Feig reader should be connected to
the PC (including serial and USB ports) at one time.
3.24
Click on the “Configuration” button on the left side control panel; then
select the “CFG1: COM-Interface” menu selection to display the
property pages.
In the box labeled Reader Mode, change the selection to ISO Host. See
the graphic below.
99-0030 Rev. C
Page 16 of 21
WaveMark, Inc. - Proprietary and Confidential
3.25
Then go to the panel on the right side of the screen and click on the
selection (0x82) Save followed by (0x81) Write. See the graphic below.
3.26
Next, select the “CFG5: Anticollision” menu selection to display the
property pages.
From the drop down on the display box labeled ONT change the value
to “1: only new selected transponders will send to the host”;
99-0030 Rev. C
Page 17 of 21
WaveMark, Inc. - Proprietary and Confidential
3.27
Then go to the panel on the right side of the screen and click on the
selection (0x82) Save followed by (0x81) Write. See the graphic below.
Testing
3.28
Plug the Mux board’s power supply connector into a +12V source at the
Mux test bench. Verify that the Mux Power LED lights.
3.29
Verify that the LED on the Reader lights green; it is lit from the
underside of the Reader so it may be difficult to see.
99-0030 Rev. C
Page 18 of 21
WaveMark, Inc. - Proprietary and Confidential
Labeling
3.30
99-0030 Rev. C
Using an ultra fine point permanent marker label the circuit board with
04-0008 & current rev. See the picture below.
Page 19 of 21
WaveMark, Inc. - Proprietary and Confidential
4.
Assembling the Mux RF to Data Assembly - P/N 03-0004
Pick List
To assemble, pick the following part number/quantities from inventory. When
building more than one, scale the values accordingly.
Qty
P/N
Part Name
) _____
04-0008
Mux/Reader Assembly (from previous step)
) _____
38-0001
Cable, 9-pin D-sub M-F Straight Thru 2.5 feet
) _____
38-0004
Cable, PC Power Cable Extender, 12 inches
) _____
38-0007
Cable, Motor to Mux Board
) _____
41-0006
Ferrite Core, snap on, .350 inch box
) _____
41-0005
Ferrite Core, snap-on, 13.00mm
) _____
12’’
86-0005
Cable Wrap, Heli-Tube
Tools and Test Equipment Required
Nut drivers: 3/16, 1/4, 5/16, 11/32
Wire cutters, small
Assembly
4.1
Select the Mux/Reader Assembly (04-0008).
4.2
Select one Motor to Mux Board cable (38-0007) and one Ferrite Core
(41-0006). Loop the Motor to Mux board cable through the Ferrite Core,
approximately 3 ½’’ from end of the cable. Plug the end near the Ferrite
Core into the Mux Board connector labeled Subnet Port 2 located at J5.
4.3
Select a PC Power Cable Extender (38-0004) from inventory and select
the roll of Heli-Tube (86-0005). Cut a piece of Heli-Tube about 12
inches long and wrap the Heli-Tube around the PC Power Cable
Extender wires.
99-0030 Rev. C
Page 20 of 21
WaveMark, Inc. - Proprietary and Confidential
4.4
Select two D-sub 9-pin M-F 2.5 foot cables (38-0001) and attach one to
each of the D-sub connectors on the Mux located at J7 & J2.
4.5
Select two snap-on ferrites (41-0005) and attach one to each of the
D-sub 9-pin cables with one turn through each ferrite. Select one snapon ferrite (41-0006) and attach it to the 4 pin power cable (38-0004).
Testing
4.6
There are no testing requirements for this assembly.
Labeling
4.7
There are no specific labeling requirements to complete this assembly.
The Mux to RF Data Assembly 03-0004 is complete.
99-0030 Rev. C
Page 21 of 21

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 21
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : 0e11ae3c-c56d-11dd-0000-dbc05e1ac1a2
Producer                        : Bullzip PDF Printer / www.bullzip.com / Freeware Edition \(not registered\)
Modify Date                     : 2008:12:05 16:13:26-05:00
Create Date                     : 2008:12:05 16:13:26-05:00
Creator Tool                    : PScript5.dll Version 5.2.2
Document ID                     : 0e11ae3c-c56d-11dd-0000-dbc05e1ac1a2
Format                          : application/pdf
Title                           : ()
Creator                         : RichLeitermannLT
Author                          : RichLeitermannLT
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UQY-HF1000A

Navigation menu