GOLD GV Water boiler — Series 3 Boiler manual • Installation • Start-Up • Maintenance Parts This manual must only be used by a qualified heating installer/ service technician. Failure to comply could result in severe personal injury, death or substantial property damage. Part No. 550-141-850/0699 GOLD GV Water boiler series 3 — manual How it works . . . ① Control module The GCM control module responds to signals from the room thermostat, air pressure switch, inlet water sensor and boiler limit circuit to operate the circulators, gas valve, igniter and blower. When a room thermostat calls for heat, the GCM starts the system circulator and blower. The GCM runs the blower long enough to purge the boiler flue passages, then turns on the igniter and lets it warm up. After a 15-second warmup, the GCM opens the gas valve, turns the igniter off, and checks for flame. The flame must come on within 4 seconds or the GCM will shut down and try the full cycle again. When the room thermostat is satisfied, the GCM turns off the boiler components and waits for the next heat call. The GCM indicator lights show normal sequence when the lights are on steady. When a problem occurs, the GCM flashes combinations of lights which indicate the most likely reason for the problem. ② Transformer ③ Blower ④ Air pressure switch ⑤ Water temperature limit switch ⑥ System circulator ⑦ Bypass circulator The control transformer reduces line voltage to 24 volts for the gas valve and limit circuit. The blower pulls in air and mixes it with gas from the gas valve. The blower forces this mixture into the burner for combustion inside the boiler chamber. The air pressure switch signals the control module, telling the control module whether air is moving through the blower. The water temperature limit switch turns off the gas valve if the temperature in the boiler goes above its setting. (The circulators will continue to run as long as there is a call for heat.) The system circulator circulates water through the external (system) piping. The flow rate of the circulator is controlled by the GCM, depending on the temperature of the water entering the boiler sections. The GCM operates the bypass circulator to mix hot water from the boiler outlet with colder return water from the system as needed to prevent condensation of flue gases in the boiler. When the water returning to the boiler is below 130 °F, the GCM regulates the bypass circulator and system circulator flow rates to raise the return water temperature up to 130 °F before it enters the boiler sections. By balancing these flow rates, the GCM can protect against condensation even if return water is as low as 60 °F. ⑧ Water temperature sensor The water temperature sensor monitors the temperature of the water entering the boiler sections. The sensor sends this information to the GCM. The GCM determines how much to adjust the circulator flow rates to provide at least 130 °F entering water. 2 Part number 550-141-850/0699 Ž Installation • Start-Up • Parts • Maintenance GOLD GV Water boiler — Series 3 a b c d e supply to system return from system combustion air inlet fitting flue outlet gas valve (see warning, right) f g h i j Part number 550-141-850/0699 pressure/temperature gauge flueway inspection port cover sensor hose trap manual air vent relief valve 85001 This boiler uses a negative-pressureregulated gas valve, set for an outlet pressure approximately –0.20" w.c.. DO NOT set the outlet pressure higher than factory setting. 3 GOLD GV Water boiler series 3 — manual Please read before proceeding Hazard definitions The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or to important information concerning the life of the product. Indicates presence of hazards that will cause severe personal injury, death or substantial property damage. Indicates presence of hazards that can cause severe personal injury, death or substantial property damage. Indicates presence of hazards that will or can cause minor personal injury or property damage. Indicates special instructions on installation, operation or maintenance that are important but not related to personal injury or property damage. Installer Read all instructions before installing. Follow all instructions in proper order to prevent personal injury or death. User • Also refer to GV Series 3 Venting supplements. • Consider piping and installation when determining boiler location. • Any claims for damage or shortage in shipment must be filed immediately against the transportation company by the consignee. • This manual is for use only by your qualified heating installer/ service technician. • Please refer to the User’s information manual for your reference. • We recommend regular service by a qualifed service technician, at least annually. Table of contents 4 See pages 6 and 7 for Table of contents. Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Please read before proceeding Failure to adhere to the guidelines on this page can result in severe personal injury, death or substantial property damage. When servicing boiler — • To avoid electric shock, disconnect electrical supply before performing maintenance. • To avoid severe burns, allow boiler to cool before performing maintenance. Boiler operation — • Do not block flow of combustion or ventilation air to boiler. • Should overheating occur or gas supply fail to shut off, do not turn off or disconnect electrical supply to pump. Instead, shut off the gas supply at a location external to the appliance. • Do not use this boiler if any part has been under water. Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control, which has been under water. Boiler water — • DO NOT use petroleum-based cleaning or sealing compounds in boiler system. Water seal deterioration will occur, causing leakage between sections. This can result in substantial property damage. • DO NOT use "homemade cures" or "boiler patent medicines". Serious damage to boiler, personnel and/or property may result. • Continual fresh makeup water will reduce boiler life. Mineral build-up in sections reduces heat transfer, overheats cast iron, and causes section failure. Addition of oxygen and other gases can cause internal corrosion. Leaks in boiler or piping must be repaired at once to prevent makeup water. • Do not add cold water to hot boiler. Thermal shock can cause sections to crack. Part number 550-141-850/0699 5 GOLD GV Water boiler series 3 — manual Contents Contents I. Prepare boiler location II. Prepare boiler Pages • Verify code compliance. Check for high altitude requirements. Provide required clearances and accessibility. Plan vent and combustion air provisions. Check existing common vents to be sure they will work when old boiler is removed from system. 8 – 15 Leave boiler on its skid until preparation complete. Install vent starter tee. Inspect/replace if necessary the gas/air orifice. Install high altitude kit (over 5,500 feet). Place boiler in position. Hydrostatically test boiler. 16 – 25 III. Water piping Select system type from navigation table on page 26, covering baseboard systems, radiator systems, radiant heating systems, heat pump systems, snow melt systems and water chiller systems. Review boiler connections pages 28 – 29, including installation of air separator and expansion tank. Review general system information, page 30. Obtain any system components needed but not on hand at the job site. Install relief valve and discharge piping. Connect system piping. Install low water cutoff and additional limit control, if required. 26 – 36 IV. Venting and combustion air Refer to Vent supplements included with boiler V. Gas piping VI. Field wiring 6 Summary 37 Connecting gas supply, including need for pipe supports. Natural gas boilers — gas line sizing (for 0.3" w.c. drop). Propane boilers — refer to gas supplier. 38 – 39 Code compliances. Wiring must be N.E.C. Class 1. Thermostat connections. Junction box installation. Field wiring diagram. 40 – 41 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Contents Contents Summary VII. Start-up • Determine water treatment needs, if any. Obtain correct antifreeze if freeze protection required. Check for gas leaks (have propane odorant verified by supplier). Fill system and purge air. Read Operating instructions, section IX, then start boiler. Check all piping and verify leak-free. Check gas valve outlet pressure (altitudes over 5,500 feet). Pages 42 – 47 VIII.Check-out procedure Complete checklist and fill out certificate. 48 – 49 IX. Operation GCM (control module) indicator lights and sequence of operation. Ladder wiring diagram (page 52). Schematic wiring diagram (page 53). Lighting instruction sheet — boiler with Robertshaw 7200DERN gas valve (page 54). Lighting instruction sheet — boiler with White-Rodgers 36E gas valve (page 55). 50 – 55 Service/maintenance schedule table (page 57). Detailed instructions for annual start-up and service. Special procedures for condensate drain line check valve (page 63, if needed) and cleaning boiler heating surfaces (page 64). 56 – 65 XI. Troubleshooting Troubleshooting procedures (page 67). Checking air pressure switch (page 68). Servicing tips and precautions — Igniter, gas valve and blower housing (page 69). Servicing tips and precautions plus indicator lights and lockout modes of GCM (control module) (page 70). Common problems and solutions (pages 72 and 73). Troubleshooting based on GCM indicator lights (pages 74 – 81). 66 – 81 XII. Replacement parts Accessory bag assembly shipped with boiler (page 83). Section assembly parts (page 84). Jacket assembly parts (page 86). Blower assembly parts (page 88). Trim assembly parts (page 90). Interior panel parts (page 92). 82 – 93 XIII.Dimensions and ratings Dimensional drawing and boiler rating table. 94 – 95 X. Service and maintenance Part number 550-141-850/0699 7 GOLD GV Water boiler series 3 — manual Ia Prepare boiler location — overview Overview of this section ❏ Verify the boiler installation will meet all applicable codes. ❏ If the boiler installation is at high altitude (over 5,500 feet) make sure to obtain and install the high altitude kit. Obtain the high altitude kit and review the instructions included. Note the venting restrictions and input reductions at altitudes over 5,500 feet. ❏ Check the boiler space to be sure minimum clearances and accessibility are available. ❏ Obtain special venting materials and make sure vent will comply with instructions. ❏ Direct vent installation (outside air piped to boiler) is optional in most cases. But, if air contamination is likely, you will have to pipe air to the boiler. Note list of contaminants on page 13. ❏ If the GV boiler is replacing a boiler being removed from a combined vent system that will still serve other appliances, follow the procedure in this manual to verify vent performance. 8 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Ib Prepare boiler location — codes & altitude Installations must follow these codes: • Local, state, provincial, and national codes, laws, regulations and ordinances. • National Fuel Gas Code, ANSI Z223.1- latest edition. • Standard for Controls and Safety Devices for Automatically Fired Boilers, ANSI/ASME CSD-1, when required. • National Electrical Code. • For Canada only: CAN/CGA B149.1 or B149.2 Installation Code and C.S.A. C22.1 Canadian Electrical Code Part 1 and any local codes. The GV boiler gas manifold and controls met safe lighting and other performance criteria when boiler underwent tests specified in ANSI Z21.13 — latest edition. High altitude installations GV boiler controls automatically reduce input with increasing altitude. See Table 1 for estimated input at altitude as a percentage of sea level input. Multiply the boiler sea level input by this percentage to obtain the estimated high altitude input. Note that the length of the venting system will also have a minor impact on input. Refer to the vent supplement for further information. No modifications to the boiler should be necessary for installations up to 5,500 feet above sea level. For higher elevations, the air pressure switch must be changed to a special high altitude switch. Refer to the high altitude kit instructions, manual Section IId. Note that the gas valve outlet pressure must be checked (and adjusted if necessary) in accordance with manual Section VIIf. Table 1 Estimated GV input at altitude Altitude (feet) % Sea level input 1,000 2,000 3,000 4,000 5,000 5,500 6,000 7,000 8,000 9,000 10,000 97 93 90 87 83 82 80 77 74 72 69 At altitudes above 5,500 feet, GV boilers can be sidewall vented only when using direct vent (ducted combustion air). GV boilers can be vertically vented in any of the configurations shown in the vent supplements. Refer to vent supplements for more detail. Part number 550-141-850/0699 9 GOLD GV Water boiler series 3 — manual Ic Prepare boiler location — clearances Clearance options: Figure 1 Large space Large space — minimum clearances between boiler and walls or obstructions as below; see Section Ie for minimum combustion/ventilation air opening sizing. The boiler space must be at least as big as shown in Figure 1 to qualify as a large space. • Air openings to a large space can be per manual Section Ie. • The space will probably be large enough for most service and maintenance to be done in place. TOP VIEW Wall 6" min 36" 6" min min Wall You can install the boiler in a space smaller than Figure 1, but no smaller than shown in Figure 2 — this is called a small space installation. • Air openings to a small space must provide at least 1 square inch free area for every 1,000 Btuh of boiler input (at least 75 sq. in. for GV-3, 105 sq. in. for GV4, 140 sq. in. for GV-5 or 175 sq. in. for GV-6). The air opening free area must be at least this size even if the boiler uses outside air. • Air openings have to be within 6 inches of the floor and 6 inches of the ceiling of the space to prevent overheating of boiler internal components. • Provide at least screwdriver clearance to jacket front panel screws for removal of front panel for inspection and minor service. • The boiler cannot be serviced in place. Pipe the boiler with unions and isolation valves so it can be slid out of the space and serviced in an adjacent area. The space has to be equipped with a door so boiler can be accessed, unpiped and removed. • No other appliance or air handler can be installed in the same space or share its air supply. Wall Small space Boiler front 36" min Wall or obstruction 85006a FRONT VIEW Ceiling 36" dripping or spraying water or rain during operation. Allowing these components to become wet could cause a boiler failure, resulting in severe personal injury, death or substantial property damage. 10 Wall Install the boiler so control system components are protected from Wall min 36" Boiler front min 6" min Floor Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Figure 2 Flooring and foundation Small space — installation with less clearance than Figure 1 – BUT – no less than below; air openings for combustion/ventilation must be as shown below even for direct vent system. Flooring The GV boiler is approved for installation on combustible flooring, but must never be installed on carpeting. TOP VIEW Do not install boiler on carpeting even if foundation is used. Fire can result, causing severe personal injury, death or substantial property damage. Wall Access DOOR with fresh air openings 10" min 4" min Boiler top 1" Wall Front Foundation min 1" min Wall Area adjacent to access door must be accessible and must allow for removal of the GV boiler for service. No other appliance or air mover (exhaust fan, etc.) may be mounted in the same space. Provide a solid brick or minimum 2-inch thick concrete foundation pad if any of the following is true: • floor can become flooded. • the boiler mounting area is not level. • high profile condensate pump is used. (Foundation thickness will depend on height of condensate pump inlet.) Refer to separate Weil-McLain supplement for details. The minimum foundation size is 16" wide by: • • 30¾" long for GV-3 or GV-4. 37¾" long for GV-5 or GV-6. 85006b SIDE VIEW Ceiling 6" max Access door 1" Residential garage installation Boiler side 1" min 6" max Floor (2) Fresh air openings — Each with at least 1 sq. inch per 1,000 Btuh of boiler input Part number 550-141-850/0699 Wall 4" min Front min Precautions Take the following special precautions when installing the boiler in a residential garage. If the boiler is located in a residential garage, per ANSI Z223.1, paragraph 5.1.9: • Mount the boiler a minimum of 18 inches above the floor of the garage to assure the burner and ignition devices will be no less than 18 inches above the floor. • Locate or protect the boiler so it cannot be damaged by a moving vehicle. 11 GOLD GV Water boiler series 3 — manual Id Prepare boiler location — vent system Removing from existing vent Failure to follow all instructions following can result in flue gas spillage and carbon monoxide emissions, causing severe personal injury or death. Correct by resizing to approach the minimum size as determined using the appropriate tables in Part 11 of that code. Canadian installations must comply with CAN/ CGA B149.1 or B149.2 Installation Code. GV special vent system Vent system When removing a boiler from an existing common vent system: At the time of removal of an existing boiler, the following steps shall be followed with each appliance remaining connected to the common venting system placed in operation, while the other appliances remaining connected to the common venting system are not in operation. a. Seal any unused openings in the common venting system. b. Visually inspect the venting system for proper size and horizontal pitch and determine there is no blockage or restriction, leakage, corrosion and other deficiencies which could cause an unsafe condition. c. Test vent system — Insofar as is practical, close all building doors and windows and all doors between the space in which the appliances remaining connected to the common venting system are located and other spaces of the building. Turn on clothes dryers and any appliance not connected to the common venting system. Turn on any exhaust fans, such as range hoods and bathroom exhausts, so they will operate at maximum speed. Do not operate a summer exhaust fan. Close fireplace dampers. d. Place in operation the appliance being inspected. Follow the lighting instructions. Adjust thermostat so appliance will operate continuously. e. Test for spillage at draft hood relief opening after 5 minutes of main burner operation. Use the flame of a match or candle, or smoke from a cigarette, cigar, or pipe. f. After it has been determined that each appliance remaining connected to the common venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace dampers, and any other gas-burning appliance to their previous conditions of use. Any improper operation of common venting system should be corrected so the installation conforms with the National Fuel Gas Code, ANSI Z223.1 — latest edition. 12 The GV boiler requires a special vent system, designed for pressurized venting with likelihood of condensation in the vent. This is referred to as ANSI Z21 Class IV, Condensing. You may use any of the vent systems covered by the GV venting supplements included in the instruction manual envelope. The GV vent starter tee is a special item designed only for the GV boiler, available from each vendor. Do not attempt to connect the vent to the GV boiler with any other means. DO NOT mix components from different systems. The vent system could fail, causing leakage of flue products into the living space, causing severe personal injury or death. Vent termination and combustion air supply The GV boiler may be vented through the roof or through a side wall. Follow the appropriate vent supplement for the vent system chosen. The maximum vent length depends on boiler size. Refer to the vent supplement to verify vent length will be acceptable. Combustion air for the GV boiler may be from inside or ducted directly to the boiler from outside. For outside air (direct vent installation), two options are available for the flue/air termination. The air supply must ALWAYS terminate at the same location as the flue, using either: 1. Vertical direct vent installation. Obtain the Throughroof or through-unused chimney kit and supplement. Find additional information in the vent supplement for the venting material chosen. 2. Sidewall vent/air termination. This requires the WeilMcLain GV vent/air intake termination kit. Refer to the instructions packed with the kit and the vent supplement for the venting material chosen. Installations above 5,500 feet altitude must be direct vent if sidewall vented. Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Ie Prepare boiler location — contamination Air contamination Please review the following information on potential combustion air contamination problems. Refer to Table 2 for products and areas which may cause contaminated combustion air. If the boiler is installed in any area likely to cause contamination, or if products which would contaminate the air cannot be removed, you must pipe combustion air to the boiler air intake. Contaminated combustion air will damage the boiler, resulting in possible severe personal injury, death or substantial property damage. Do not install GV boiler in a laundry room or pool facility, for example, without using ducted outside air. These areas will always contain contaminants. Table 2 Corrosive contaminants Products to avoid Areas likely to have contaminants Spray cans containing chloro/fluorocarbons Dry cleaning/laundry areas and establishments Permanent wave solutions Swimming pools Chlorinated waxes/cleaners Metal fabrication plants Chlorine-based swimming pool chemicals Beauty shops Calcium chloride used for thawing Refrigeration repair shops Sodium chloride used for water softening Photo processing plants Refrigerant leaks Auto body shops Paint or varnish removers Plastic manufacturing plants Hydrochloric acid/muriatic acid Furniture refinishing areas and establishments Cements and glues New building construction Antistatic fabric softeners used in clothes dryers Remodeling areas Chlorine-type bleaches, detergents, and cleaning solvents found in household laundry rooms Garages with workshops Adhesives used to fasten building products and other similar products Part number 550-141-850/0699 13 GOLD GV Water boiler series 3 — manual If Prepare boiler location — air openings GV combustion air options Single air opening option Using inside air — non-direct vent The GV boiler can use inside air if no contaminants are present in the boiler space. A single air opening within 12 inches of the ceiling may be used where the GV boiler is installed in a large space (clearances per Figure 1) with other appliances. The other appliances must all be installed with at least 1 inch clearance from the sides and back, and 6 inches from the front. The GV boiler must have minimum clearances as shown in Figure 1. The single air opening may be connected from outside to the appliance space by any of the methods of Figure 3. The free area of the opening must also be at least equal to the combined area of all appliance vent connectors OR sized per the following, whichever result is larger: Using outside air — direct vent Combustion air can be ducted directly from outside to the GV boiler air intake fitting. The installation is defined as direct vent (also referred to as sealed combustion). Sizing air openings Air openings to the GV boiler space are always required, regardless whether combustion air is taken from inside or outside. These air openings provide for ventilation (as well as combustion air) to prevent overheating of the boiler controls and boiler space. Air is also needed for other appliances located in the same space. Use Figure 3, cases a through d, depending on how the air is supplied and whether the space contains only the GV or other appliances as well. The air opening sizing of Figure 3 is based on ANSI Z223.1, National Fuel Gas Code, intended for natural draft appliances. The GV boiler is not natural draft, so its requirements differ. Air openings must be sized to handle all appliances and air movers (exhaust fans, etc.) using the air supply. Louver allowance The free area of openings means the area after reduction for any installed louvers or grilles. Be sure to consider this reduction when sizing the air openings. GV with other appliances If the GV boiler is installed in a large space (clearances per Figure 1) providing air for a water heater or other gas appliance, size the air openings as follows: GV direct vent — large shared space Provide two openings per Figure 3, based only on the size of the other appliances and air movers. No additional air opening area is required for the GV boiler. GV inside air — large shared space If the GV combustion air comes from the inside space, size two air openings for the total of all appliances and air movers, including the GV boiler. Use the formula from the appropriate case in Figure 3. 14 GV direct vent — large shared space — single air opening Size the single air opening for 1 square inch of free opening for each 3,000 Btuh of all appliances other than the GV. No additional air opening is needed for the GV. GV inside air — large shared space — single air opening Size the air opening for 1 square inch of free opening for each 3,000 Btuh of all appliances, including the GV. GV without other appliances If the GV boiler is installed in a space by itself, with no other appliance or air mover using air from the space, and with clearances around the boiler no less than those shown in Figure 1 for large space installations: GV direct vent — large space — alone Air is needed only for ventilation. Size the air openings for any of the cases of Figure 3 for a free area of at least: 1 square inch per 8,000 Btuh of GV input for each of the two openings. (If a single opening within 12 inches of the ceiling is used, size the opening for 1 square inch of free area for each 3,000 Btuh of GV input.) GV inside air — large space — alone Size the air openings for any of the cases of Figure 3 for a free area of at least: 1 square inch per 4,000 Btuh of GV input for each of the two openings. (If a single opening within 12 inches of the ceiling is used, size the opening for 1 square inch of free area for each 3,000 Btuh of GV input.) Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance 0 to 12" Each opening free area = 1 sq. inch per 1,000 Btuh Add air openings to outside if building is tight construction. Other appliances a— Air opening Air openings: GV in space with other appliances a Flue Air from inside building Air (direct vent) (optional) GV b 0 to 12" Each opening free area = 1 sq. inch per 4,000 Btuh Other appliances Air b— Flue Air (direct vent) (optional) GV Air opening Figure 3 Motorized air dampers If the air openings are fitted with motorized dampers, electrically interlock the damper to: • Prevent the boiler from firing if the damper is not fully open. • Shut the boiler down should the damper close during boiler operation. To accomplish this interlock, wire an isolated contact (proving the damper open) in series with the thermostat input to the boiler. The boiler will not start if this contact is open, and will shut down should it open during operation. Air opening Tight construction ANSI Z223.1 defines unusually tight construction where: a. Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of 1 perm or less with openings gasketed, and . . . b. Weatherstripping has been added on openable windows and doors, and ... c. Caulking or sealants are applied to areas such as joints around windows and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and in other openings. For buildings with such construction, provide air openings into the building from outside, sized per the appropriate case in Figure 3 if appliances are to Exhaust fans and air movers The appliance space must never be under a negative pressure, even if the appliance(s) are installed as direct vent. Always provide air openings sized not only to the dimensions required for the firing rate of all appliances, but also to handle the air movement rate of the exhaust fans or air movers using air from the building or space. Outside Special considerations use inside air for combustion and ventilation. Air opening GV in small space (less than Fig. 1) — alone For all vent/air situations, whether air is taken from inside or outside, provide two openings, each with minimum free area of: 1 square inch per 1,000 Btuh of GV input. The openings must be within 6 inches of the ceiling and 6 inches of the floor as shown in Figure 2 for small space installations. Air 0 to 12" 0 to 12" Air directly from outside Outside or ventilated attic d Each opening free area = 1 sq. inch per 4,000 Btuh Other appliances d— Air through horizontal ducts Flue 0 to 12" Each opening free area = 1 sq. inch per 2,000 Btuh Air (direct vent) (optional) GV Other appliances Flue Air 12" — or — Air (direct vent) (optional) GV Air Ventilated crawl space Part number 550-141-850/0699 Air opening c Outside Air through vertical ducts (or inlet air from ventilated crawl space) Air opening 85005 c— 0 to 12" 15 GOLD GV Water boiler series 3 — manual IIa Prepare boiler — overview Overview of this ❏ Leave the boiler on its skid until installation site is ready and boiler prep is complete per this section. section ❏ Install vent starter tee and condensate drain line. ❏ Inspect gas/air orifice plate to verify model size and gas markings agree with boiler and application. Install propane gas/air orifice for propane installations. ❏ Install high altitude kit for altitudes more than 5500 feet above sea level. ❏ Place boiler in position and install jacket rear panel. ❏ Plug openings and hydrostatically test boiler. Remove plugs. IIb Prepare boiler — vent starter tee & drain Install vent starter tee and condensate drain hose Use only the vent starter tee of the same manufacturer as the vent components to be used. Do not mix components from different systems. The vent system could fail, causing flue gas spillage, resulting in severe personal injury or death. Install vent starter tee as shown in Figure 4. 1. Remove jacket access panel (item 1). You can rotate the plate out of the way, leaving the air hose connected to the air intake fitting, or loosen the hose clamp (item 2) and pull the air hose off of the fitting as shown in Figure 4. 2. Remove the hex nuts (item 5) from the vent starter tee studs at the boiler vent connection. 3. Remove the vent starter tee gasket (item 4) from the studs. 4. Clean the surface of the boiler flue connection to assure a good seal. Use emery cloth if necessary to remove any accumulated rust. 5. Place the vent starter tee gasket (item 4) over the studs. 6. Slide the holes in the vent starter tee flange (item 3) over the studs. 7. Apply the (4) hex nuts (item 5), align the vent starter tee (item 3) and tighten the nuts uniformly. Install condensate trap hose as shown in Figure 4. 1. Loosen and slide a spring hose clamp (item 8) over each end of the condensate drain hose (item 6). 2. Loosen the clamp and slide one end of the hose over the CPVC drain elbow (item 7). Slide clamp into position and release. 3. Attach and clamp the other end of the hose to the drain connection on the bottom of the vent starter tee (item 3). Replace jacket access panel (item 1), reconnecting the air hose to the air intake fitting if necessary. 16 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance IIb Figure 4 Prepare boiler — vent starter tee & drain (cont.) Install vent starter tee and condensate drain hose before placing boiler. Screw hole and notch, located in base rail under vent outlet Base rail Insert CPVC elbow into bracket. Then attach bracket to base rail with screw as shown at left. 10-32 x 3/8" Vent starter tee — not included with boiler. See information below. The vent starter tee is NOT supplied with the boiler. Obtain this part as a separate purchase from your Weil-McLain wholesaler. 85002 Part number 550-141-850/0699 The vent starter tee shown is for Saf-T Vent®. Use only the vent tee made for the vent system you are using. DO NOT mix different brands of vent system components. The vent system could fail to operate properly, causing leakage of flue products into the living space, resulting in severe personal injury or death. 17 GOLD GV Water boiler series 3 — manual IIc Prepare boiler — orifice plate The correct orifice plate must be used. Failure to do so will result in severe Check for correct personal injury, death or substantial property damage. orifice plate and replace if necessary Natural gas: For natural gas installations, inspect the silver gas/air orifice plate marking. It must be the same as the boiler size. If the orifice plate is stamped with another size, obtain the correct plate from your wholesaler. The boiler size is stamped where the “X” is shown in the plate stamping, Figure 5b. Propane: For propane installations, replace the silver gas/air orifice plate with the red/white plate, per following instructions. Ensure the red/white plate boiler size is correct for the GV boiler being installed. The boiler size is stamped where the “X” is shown in the plate stamping, Figure 5b. Also fill out the propane label in the conversion kit and attach to the left side of the jacket, above the gas inlet opening, as shown in Figure 5a. Plate installation Access the bottom of the blower housing as shown in Figure 5a. To inspect the plate only, read the marking on the plate edge. It must read the same as the boiler size and fuel. To replace the plate, using a manual screwdriver or nut driver, see Figure 5b: 1. Loosen screws 1 and 2 two full turns. 2. Remove screws 3 and 4. 3. Pull the gas/air orifice plate forward to remove it. 4. Slide in the new plate as shown in Figure 5b. The red side of a propane plate must go next to the blower housing as shown. 5. Replace screws 3 and 4. Tighten all four screws securely and uniformly. DO NOT overtighten. DO NOT exceed 40 inch-pounds torque. 6. Bend down plate label tab at score mark as shown in lower right corner of Figure 5b. Remove jacket front panel to access the bottom side of the blower housing. Figure 5a Check for correct orifice plate and replace if necessary. Complete the propane conversion label included with the conversion kit. Install label on jacket left side, as shown. Leave boiler on its back, on the skid, until inspection/ replacement is completed. 85004a 18 Leave the boiler on its back, on the skid as shown, until you have checked the gas/air orifice plate and replace it if necessary. Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Figure 5b Checking and replacing gas/air orifice plate. For propane installations, replace silver plate with red/white propane plate. DO NOT use electric or pneumatic screwdrivers to remove or tighten the gas/air boss screws. Hand-tighten only, using manual screwdriver. Should the torque exceed 40 inch-pounds, the threaded holes could strip out, causing an inadequate seal of the orifice plate. Failure to properly seal the plate to the housing could result in a gas leak, causing severe personal injury, death or substantial property damage. White side (propane plate) Warning label side (natural gas) (Install with this side toward air inlet hose) Gas/air manifold Bottom side of boiler front section GVX PROP GV XP RO P Propane — red side Natural — plain side Install plate with red side (propane) or plain side (natural) against the blower housing. Part number 550-141-850/0699 Orifice plate after bending along score mark. This makes the plate identification readable after installation. 85004b 19 GOLD GV Water boiler series 3 — manual IId Prepare boiler — high altitude kit Obtain high altitude When required kit For installations at altitude more than 5,500 feet above sea level, a special high altitude air pressure switch is required. In addition, the gas valve outlet pressure setting must be checked, and adjusted if necessary, per the instructions in manual Section VIIf, altitude over 5,500 feet. Obtain the GV high altitude kit from your local WeilMcLain distributor. This kit includes the high altitude air pressure switch and a special tool needed for accessing the adjusting screw on some gas valves. The kit also includes tubing fittings as described in manual. Install high altitude air pressure switch 1. See Figure 5c (switch shown with wires removed). 2. Remove the two (RED) control wires from the air pressure switch spade terminals. 3. Remove the factory-installed air pressure switch (loosen top screw and remove bottom screw holding switch to jacket interior panel). 4. Install the high altitude air pressure switch in the same location. 5. Carefully replace the hoses on the new switch, with the red hose on the hose barb closest to the interior panel, as shown in Figure 5c. The white hose goes on the outer hose barb. 6. Replace the two (RED) control wires on the new pressure switch spade terminals. Check gas valve outlet pressure After following the start-up procedures of manual Section VII, follow the procedures of Section VIIf to measure gas valve outlet pressure and adjust if necessary. Failure to check gas valve outlet pressure and adjust, if necessary, could result in severe personal injury, death or substantial property damage. Carefully follow the guidelines given in this manual. 20 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance — altitudes above 5,500 feet ONLY Figure 5c Air pressure switch mounting and sensor hoses Jacket left side panel White hose Red hose Interior panel (2) 10-32 x 3/8" Phillips/hex screws Boiler top 85052 Part number 550-141-850/0699 21 GOLD GV Water boiler series 3 — manual IIe Prepare boiler — place in position Position boiler After installing vent starter tee, inspecting (replacing if necessary) the gas/air orifice and installing the high altitude kit (if required), move the boiler near its position. Figure 6 shows the boiler with the front and top panels replaced. These panels may be left off if desired until the installation has been completed. Refer to Figure 6 for placement sequence: ➀ Wearing heavy gloves, carefully rotate the boiler over onto its base rail legs. ➁ Clip the shipping strap securing the skid to the boiler block assembly. Remove the skid and strap. ➂ Attach the jacket rear panel as shown using (4) #10 x ¾" screws provided in the accessory bag. Boiler is heavy and contains some sheet metal parts which may have sharp edges. Wear gloves when handling and take proper precautions when moving. Failure to do so will result in severe personal injury, death or substantial property damage. 22 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Figure 6 Rotating boiler into position, removing skid and installing jacket rear panel Carefully rotate boiler onto base rail legs as shown ROTATE ROTATE Install jacket rear panel with (4) screws, #10 x 3/8" Clip shipping strap Part number 550-141-850/0699 85003 23 GOLD GV Water boiler series 3 — manual IIf Prepare boiler — pressure test Perform hydrostatic pressure test 5. Slowly reopen drain valve (item 2) until test pressure of not more than 45 psi is reached on the pressure gauge. Pressure test boiler before attaching water or gas piping (except as noted below) or electrical supply. 6. Test at no more than 45 psi for no more than 10 minutes. Prepare boiler for test (Fig. 7) Do not leave boiler unattended. ➀ Connect a hose from water supply to fill and drain boiler for hydrostatic test. Hose is not included with boiler. ➁ A cold water fill could expand and cause excessive pressure, resulting in severe personal injury, death or substantial property damage. Connect hose to boiler drain valve. Make sure hose can also be used to drain boiler after test. ➂ Remove 1" nipple, 1" tee, bushing and pressure/ temperature gauge from accessory bag. Pipe to boiler supply connection as shown. Use pipe dope sparingly. ➃ Connect a nipple and shutoff valve to system supply connection on the 1" tee. This valve will be used to bleed air during the fill. Valve and nipple are not included with boiler. ➄ Connect a nipple and shutoff valve to system return connection at circulator flange. This valve will be used to bleed air during the fill. Valve and nipple are not included with boiler. ➅ Install a ¾" pipe plug in the relief valve opening, top of the rear boiler section, as shown. Plug is not included with boiler. 7. Make sure constant gauge pressure has been maintained throughout test. Check for leaks. Repair if found. Leaks must be repaired at once. Failure to do so can damage boiler, resulting in substantial property damage. Do not use petroleum-based cleaning or sealing compounds in boiler system. Severe damage to boiler will occur, resulting in substantial property damage. Drain and remove fittings Fill and pressure test 1. Disconnect fill water hose from water source. 1. Connect fill water supply through drain valve (item 2). 2. Drain boiler at drain valve or out hose, whichever provides best access to drain. Close drain valve and remove hose after draining. 2. Fill boiler with water (be sure bleed valves at 4 and 5 are open). 3. When water flows from bleed valves, shut off water at drain valve. 3. Remove nipples and valves at 4 and 5 unless they will remain for use in the system piping. 4. Remove plug (item 6) from relief valve tapping. 4. Close bleed valves. 24 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Figure 7 Piping connections for hydrostatic test To fill/drain 85007 Part number 550-141-850/0699 25 GOLD GV Water boiler series 3 — manual IIIa Water piping — overview Overview of this ❏ Select suggested piping from the following table, based on the type of system in which you are installing the GV boiler. section ❏ Review boiler connections, pages 28 – 29 — information on supply and return connections at boiler and key system components (air separator and expansion tank). ❏ Review page 30, information applying to all systems. ❏ Obtain any system components needed but not on hand or available at jobsite. ❏ Install boiler relief valve and pipe discharge to a safe location per guidelines in this section. ❏ Install system piping and boiler connections. ❏ Install additional limit control (if required for code compliance) and low water cutoff if required. For heating system with . . . See pages 27 – 30 and . . . Baseboard, finned tube or cast iron 31 Radiators, cast iron 32 Radiant floor, wall or ceiling — single zone (note 1) 33 Radiant floor, wall or ceiling — multiple zones 34 Heat pump (note 1) 33 Snow melt plus space heating 35 Control valve (note 2) 34 Water chiller 36 Note 1: Install a temperature limit control in the supply piping to protect the system. Note 2: Apply these piping designs for outdoor reset or any system requiring automatic supply temperature regulation. 26 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance IIIb Install relief valve Water piping — relief valve Refer to Figure 8 for location of the relief valve on the boiler. Install the relief with the spindle vertical in the ¾" tapping on top left of the back section, as shown. To avoid water damage or scalding due to valve operation, a metal discharge line must be connected to relief valve outlet and run to a safe place of disposal. Terminate the discharge line to eliminate possibility of severe burns should the valve discharge. Discharge line must be as short as possible and be the same size as the valve discharge connection throughout its entire length. Discharge line must pitch downward from the valve and terminate at least 6" above the floor drain where any discharge will be clearly visible. The discharge line shall terminate plain, not threaded, and must be rigid metallic pipe of material suitable for temperatures of 375 °F or greater. Do not pipe the discharge to any place where freezing could occur. No shutoff valve shall be installed between the relief valve and boiler, or in the discharge line. Do not plug or place any obstruction in the discharge line. Failure to comply with the above guidelines could result in failure of the relief valve to operate, resulting in possibility of severe personal injury, death or substantial property damage. Test the operation of the valve after filling and pressurizing system by lifting the lever. Make sure the valve discharges freely. If the valve fails to operate correctly, replace it with a new relief valve. Figure 8 1 Jacket plug for unused relief valve jacket opening. 2 Jackets are provided with two relief valve openings because each jacket size is used for two boiler sizes. Cover the unused opening with the plug provided. 3 Boiler relief valve (from accessory bag) 4 ¾" x 3" nipple, provided in accessory bag 5 ¾" relief valve tapping in back section 6 Connect minimum ¾" discharge piping to relief valve. See WARNING above. Install and pipe relief valve 85008 Part number 550-141-850/0699 27 GOLD GV Water boiler series 3 — manual IIIc Water piping — boiler connections Supply & return connections Always connect supply and return connections to the boiler as shown in Figure 9. (Note in the following and in the suggested piping drawings in this manual that the expansion tank and air separator location will depend on the system piping.) Operating pressure of system, after temperature expansion above cold fill pressure, should not exceed 24 PSIG to avoid weeping of relief valve. Install an automatic air vent on top of the air separator, per separator manufacturer’s instructions. Closed-type expansion tank: Air separator Install an air separator in the piping as shown. For single-zone systems, install the air separator in the return piping as shown in Figure 9. This allows mounting the automatic air vent and expansion tank off of the separator. Expansion tank Figures 9 and 10 show typical installation of the expansion tank when the boiler is connected to a zonevalve zoned baseboard system (see Figure 10). Always locate the air separator and expansion tank as shown in the suggested piping drawings, Figures 10 through 16. Ensure that the expansion tank size will handle boiler and system water volume and temperature. See tank manufacturer’s instructions and ratings for details. Additional tanks may be added to the system if needed to handle the expansion. These tanks may be installed by connecting to tees in the system piping. Undersized expansion tanks cause system water to be lost from the relief valve and makeup water to be added through the fill valve. Eventual section failure can result. Always locate the cold water fill connection at the expansion tank. Never locate this elsewhere in the system. Diaphragm- or bladder-type tank: Refer to Figure 9 for suggested piping when using a diaphragm- or bladder-type expansion tank. 28 Figure 10 shows suggested piping when using a closedtype expansion tank, in which the air is directly in contact with tank water. Connect piping (½" or ¾") from the air separator top outlet to the tank fitting. Slope any horizontal piping a minimum of 1 inch per 5 feet of horizontal pipe. Always use a tank fitting, such as the B&G Tanktrol or Taco Taco-Trol (shown). The fitting reduces gravity flow of water in the piping to the tank, avoids air bubbling through the tank water, and provides the proper fill height in the tank. Correct all leaks in the system or tank piping. Leaks allow air to escape from the system and will cause waterlogging of the tank. This will result in water loss through the boiler relief valve due to over-pressurization. NEVER use an automatic air vent in a system equipped with a closed-type expansion tank. The air removed from the system will cause waterlogging of the expansion tank. Closed-type expansion tank — Follow tank manufacturer’s instructions for filling the tank. Typical tank sizing provides for approximately 12 PSIG when the tank is filled to the normal level and system water is cold. Note that boiler relief valve is set for 30 PSIG. Operating pressure of system, after temperature expansion above cold fill pressure, should not exceed 24 PSIG to avoid weeping of relief valve. Diaphragm- or bladder-type expansion tank — Control fill pressure with the tank air charge Backflow preventer pressure. Always check pressure and charge tank with tank removed from system to be sure reading is accurate. Boiler relief valve is set for 30 PSIG. Where required by codes, install a backflow preventer in the cold water fill line, as shown in suggested piping diagrams on following pages. Install a check valve if a backflow preventer is not installed. Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Figure 9 Piping to single-zone system using diaphragm- or bladder-type expansion tank. Boiler connections are 1" NPT (supply from 1" tee, return to 1" system circulator flange). Relief valve discharge piping — see page 27 Boiler isolation valves 3 Fill valve 4 Air separator 5 Automatic air vent Figure 10 Piping closedtype expansion tank Backflow preventer or check valve System supply piping 8 System return piping 9 Diaphragm-type expansion tank — always locate as shown in the suggested piping drawings, Figures 10 through 16 1 6 2 7 To cold fill To cold fill 85011 10 Pressure reducing valve 11 Quick-fill bypass valve 12 Closed-type expansion tank — 85010 Locate the air separator as shown in the suggested piping diagram, Figures 11 through 16 on the following pages. Pipe diaphragm- or bladder-type expansion tanks to the bottom of the separator. Part number 550-141-850/0699 always locate as shown in the suggested piping drawings, Figures 10 through 16 13 Tank fitting Pipe closed-type (air in contact with water) tanks to the top of the air separator. Always connect the fill line to the expansion tank location, as shown above and in the suggested piping. 29 GOLD GV Water boiler series 3 — manual IIId Zoning with circulators Water piping — all systems The GV internal system circulator cannot be removed from the boiler for use as one of the zone circulators. It must remain as shipped from the factory to allow proper flow control inside the boiler. You will need a circulator for each zone. Size the common (primary) pipe for the combined flow of all circulators, or with a pipe cross-sectional area at least equal to the total areas of all zone supply pipes. You may also use the alternative sizing chart at right, based on maximum flow of 10 gmp per circulator. Install and wire a separate relay for each zone circulator. Zoning with zone valves Alternate primary manifold sizing (max 10 gpm per circulator) Number of circulators Suggested pipe size 1 1" 2–3 1½" 4–5 2" 6–8 2½" 9 – 12 3" Each zone in the piping diagrams in this section is shown with an isolation valve on each side. Substitute a memory-stop valve for one of these in each zone in order to use the memory-stop valve for balancing flow as well as isolation. Provide a separate 24-volt transformer to power the zone valves. Size the transformer to handle the total rated load of all connected zone valves. Additional components If installation is to comply with ASME or Canadian requirements, an additional high temperature limit is needed. • Purchase and install in system supply piping between boiler and isolation valve. • Wire the second limit control in series with the boiler limit control. • Set the second limit control at least 20 °F above the boiler limit control setting (maximum setting 240 °F). A low water cutoff device is required when boiler is installed above radiation level or by certain state or local codes or insurance companies. Use low water cutoff designed for water installations. Electrode probe-type is recommended. Purchase and install in tee in supply piping above boiler. If boiler is connected to heating coils located in air handling units where they can be exposed to refrigerated air, use flow control valves or other automatic means to prevent gravity circulation during cooling cycle. Circulation of cold water through the boiler could result in damage to the heat exchanger, causing possible severe personal injury, death or substantial property damage. Do not remove either of the GV internal pumps for use elsewhere in the system. Both pumps are required for proper operation. Removing a pump will cause the boiler to malfunction. Substantial property damage could result. Never install another pump in series with the GV boiler. Forced flow can cause improper operation of the boiler controls. Substantial property damage could result. 30 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance IIIe Water piping — baseboard system Figure 11a Baseboard system (finned tube or cast iron) — zone valve zoning Baseboard system piping Apply Figure 11a (zone-valve zoning) or 11b (circulator zoning) to systems using baseboard heaters. The heaters can be any baseboard style, including finned tube or cast iron. Zone 2 Zone 1 The boiler internal “System circulator” can be used to circulate most zone-valve zoned systems as shown in Figure 11a. For systems requiring higher flow, apply the suggested piping of Figure 12a. The boiler internal circulators must be left in the boiler. They cannot be removed for use a a zoning circulator. Provide a circulator for each zone when circulator zoning, and pipe the system as in Figure 11b. Cold water fill GV Boiler 85013a Figure 11b Baseboard system (finned tube or cast iron) — circulator zoning Legend 1 Boiler isolation valves Zone 2 2 Automatic air vent (with diaphragm-type expansion tank), or connect to tank fitting (closed-type expansion tank). Zone 1 3 Diaphragm- or bladder-type expansion tank, if used. (For closed-type expansion tank, pipe from top of air separator to tank fitting as in Figure 10.) 12" max Cold water fill 4 Zone valve 5 Zone circulator 6 Flow/check valve GV Boiler 7 Hose bibb purge valve 85017 Part number 550-141-850/0699 8 Boiler pressure/temperature gauge 31 GOLD GV Water boiler series 3 — manual IIIf Water piping — radiator system Figure 12a Radiator system — zone-valve zoning Radiator system piping Apply Figure 12a (zone-valve zoning) or 12b (circulator zoning) to systems using standing cast iron radiators. This applies to gravity water systems and converted steam systems using columnar, tubular or recessed cast iron radiators. Zone 2 Zone 1 The suggested piping for zone-valve zoning radiator systems differs from baseboard systems because of the high water content of cast iron radiators. The GV internal circulators automatically regulate supply and internal bypass flow based on the temperature of the water returning to the boiler. At the start of many heating cycles in a radiator system, the water in the radiators is cool. So the boiler would slow down system flow rate while sending out relatively hot water. This could cause heat distribution problems. Install a separate system circulator as shown in Figure 12a when zoning with zone valves. The separate circulator assures a relatively constant temperature drop through the system. 12" max Cold water fill GV Boiler 85013b Figure 12b Radiator system — circulator zoning The boiler internal circulators must be left in the boiler. They cannot be removed for use a a zoning circulator. Provide a circulator for each zone when circulator zoning, and pipe the system as in Figure 12b. Legend 1 Boiler isolation valves Zone 2 2 Automatic air vent (with diaphragm-type expansion tank), or connect to tank fitting (closed-type expansion tank). Zone 1 3 Diaphragm- or bladder-type expansion tank, if used. (For closed-type expansion tank, pipe from top of air separator to tank fitting as in Figure 10.) 12" max Cold water fill 4 Zone valve 5 System or zone circulator 6 Flow/check valve GV Boiler 7 Hose bibb purge valve 85017 32 8 Boiler pressure/temperature gauge Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance IIIg Water piping — single-zone radiant or heat pump system Single-zone radiant heating or heat pump piping You may also apply the suggested piping of either Figure 14a or 14b if you want automatic supply temperature regulation or outdoor reset temperature control. Radiant heating systems and heat pump systems usually require system supply water temperatures below 130 °F. But the boiler outlet water temperature will be at least 150 °F during most operating conditions. So the piping must include a method of reducing the supply water temperature to the system. For additional information and alternatives in piping for radiant heating systems, refer to Weil-McLain AlumiPex Controls • Pumps • Wiring Design Guide. Figure 13 uses two balancing valves to manually adjust the supply water temperature. Follow the instructions below to adjust these valves. Install the supply temperature limit control (item 14) as shown to protect the system from overtemperature conditions. Note also that this piping requires a separate system circulator, as shown, because of the higher flow rates of radiant and heat pump systems. Adjust balancing valves Manual adjustment of the supply temperature is limited to single-zone systems because multi-zone systems will cause varying loads, making it unlikely an acceptable valve setting could be found. See Figure 14a or 14b for multizone systems. Figure 13 Single-zone radiant heating or heat pump system Use valves 15 and 16 to mix boiler supply water with system return water, reducing supply water temperature to the system. 1. Subtract the design system supply temperature from 150 °F. Call this number the temperature difference. 2. Open valve 16 and close valve 15. 3. Start the boiler and system. 4. Let the system warm up for about 15 minutes. 5. Note the temperature at gauge 9 (system supply) and gauge 8 (boiler supply). 6. Slowly close valve 16 while opening valve 15 until gauge 9 reads lower than gauge 8 by at least the temperature difference found in step 1. 7. Example: For a design supply temperature of 100 °F, the temperature difference would be 150 °F minus 100 °F, or 50 °F. Set the valves until gauge 9 reads at least 50 °F lower than gauge 8. Load Legend 12" max Cold water fill GV Boiler 85015a Part number 550-141-850/0699 1 Boiler isolation valves 2 Automatic air vent (with diaphragm-type expansion tank), or connect to tank fitting (closed-type expansion tank). 3 Diaphragm- or bladder-type expansion tank, if used (For closed-type expansion tank, pipe from top of air separator to tank fitting as in Figure 10.) 5 System circulator 7 Hose bibb purge valve 8 Boiler pressure/temperature gauge 9 System supply temperature gauge 10 Return temperature gauge 14 Supply temperature limit control — Set at a temperature below the maximum allowed for the system or as directed by the system designer. 15 Balancing valve 16 Balancing valve 33 GOLD GV Water boiler series 3 — manual IIIh Water piping — multi-zone radiant system Figure 14a Manual bypass; fixed temp operation only Zone 2 Multi-zone radiant heating system piping Multi-zone systems require automatic regulation of the system supply temperature because of widely varying load conditions. Figure 14a (zone-valve zoning) and Figure 14b (circulator zoning) show suggested piping for these systems. Zone 1 Select an automatic temperature control valve or motoroperated valve which can be adjusted for the desired supply water temperature. Zone-valve zoning — The suggested piping uses a separate circulator for system circulation to provide the higher flow typical of radiant heating systems and to assure good temperature distribution in the system when the return water temperature is low. Cold water fill 12" max Circulator zoning — The GV internal circulators must not be removed. Provide a separate circulator for each zone. GV Boiler Outdoor reset control 85015b Figure 14b Auto return temp regulation; outdoor reset or fixed temp Zone 2 Apply Figure 14a or 14b for any system intended for outdoor reset of the supply water temperature. Use a motor-operated three-way valve and an outdoor reset temperature control system. Legend 1 Boiler isolation valves Zone 1 2 Automatic air vent (with diaphragm-type expansion tank), or connect to tank fitting (closed-type expansion tank). 3 Diaphragm- or bladder-type expansion tank, if used (For closed-type expansion tank, pipe from top of air separator to tank fitting as in Figure 10.) Cold water fill 4 Zone valve 12" max 5 System or zone circulator 6 Flow/check valve 7 Hose bibb purge valve 8 Boiler pressure/temperature gauge 9 System supply temperature gauge GV Boiler 10 Boiler return temperature gauge 85018b 34 13 Supply temperature automatic mixing valve Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance IIIi Water piping — snow melt system Figure 15a Manual bypass valves; for fixed temp operation only Snow melt heat exchanger Piping snow melt systems or combination snow melt/ space heating systems Combination snow melt/space heating systems will have widely varying system return temperatures. So these systems require automatic return water temperature as shown in Figure 15a (zone-valve zoning) or Figure 15b (circulator zoning). Heating zone(s) Select an automatic temperature control valve or motoroperated valve which can be adjusted to provide a return water temperature of at least 60 °F. Any setting higher than 60 °F will also be acceptable. 12" max Cold water fill Zone-valve zoning — The suggested piping uses a separate circulator for system circulation to assure good temperature distribution in the system when the return water temperature is low. Circulator zoning — The GV internal circulators must not be removed. Provide a separate circulator for each zone. GV Boiler The return water temperature to the boiler must be at least 60 °F. Provide and apply means to regulate the return temperature. Failure to do so can result in boiler control operation problems, causing possible significant property damage. 85014b Figure 15b Auto return temp regulation; for outdoor reset or fixed temp Snow melt heat exchanger Legend Heating zone(s) 1 Boiler isolation valves 2 Automatic air vent (with diaphragm-type expansion tank), or connect to tank fitting (closed-type expansion tank). 12" max 3 Diaphragm- or bladder-type expansion tank, if used (For closed-type expansion tank, pipe from top of air separator to tank fitting as in Figure 10.) Cold water fill 4 Zone valve 5 System or zone circulator 6 Flow/check valve 7 Hose bibb purge valve 8 Boiler pressure/temperature gauge GV Boiler 9 System supply temperature gauge 85016 Part number 550-141-850/0699 12 Return temperature automatic mixing valve 35 GOLD GV Water boiler series 3 — manual IIIj Water piping — water chiller systems Water chiller systems Figure 16 Installing GV boiler in system with water chiller Pipe the boiler and water chiller as shown in Figure 16. Expansion tank 12" max Balancing valve Install boiler, as shown, so chilled medium is piped in parallel with heating boiler. Use appropriate valves to prevent chilled medium from entering boiler. See Figure 16 for typical installation of balancing valve and check valve. Fill Pump System supply shutoff valve Flow/check valve Install the flow/check valve in the boiler supply piping, as shown in Figure 16, to prevent gravity circulation during the cooling cycle. Water chiller shutoff valves Strainer If boiler is connected to heating coils located in air handling units where they can be exposed to refrigerated air, use flow control valves or other automatic means to prevent gravity circulation during cooling cycle. 36 Boiler Check valve shutoff valve System return 85012 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance IV Venting and combustion air GV boiler must be vented and supplied with combustion and ventilation air as described in GV Series 3 Venting supplements packed in envelope assembly with boiler. Failure to do so will cause severe personal injury or death. Install vent piping and air piping (if used) per appropriate Vent supplement included in boiler envelope assembly. Refer to Vent supplement and to manual Section I regarding requirements for: • vent system • combustion air openings • combustion air quality Use direct vent (sealed combustion) if combustion air quality cannot be assured to be free of contaminants. Refer to page 13 for a list of potential contaminants and locations likely to contain them. Operating the boiler with contaminated air will damage the boiler sections and vent, resulting in possible boiler failure or leakage of flue products, causing severe personal injury, death or substantial property damage. Part number 550-141-850/0699 37 GOLD GV Water boiler series 3 — manual V Gas piping Connecting gas supply piping to boiler Do not connect gas supply to boiler or attempt to operate boiler unless the correct orifice plate has been verified or installed in accordance with manual Section IIc. Except where otherwise instructed in this manual, do not attempt to measure or adjust the outlet pressure setting of the gas valve. The gas valve is factory set to a slight negative pressure, and is operated as a negative-pressure regulated valve. Failure to comply will result in malfunction of the boiler, causing severe personal injury, death or substantial property damage. Failure to apply pipe dope as detailed above can result in severe personal injury, death or substantial property damage. Natural Gas: 1. Refer to Table 3 for pipe length and diameter. Size gas supply piping for total flow to all connected appliances. For each GV boiler, provide for the following gas flow (cfh = cubic feet per hour): GV-3 70 cfh GV-5 140 cfh GV-4 105 cfh GV-6 175 cfh 1. Refer to Figure 17 to connect gas supply to ½" npt boiler gas connection. Use wrench to hold factoryinstalled gas piping nipple. Table 3 is only for gas of specific gravity 0.60 at 2. Support piping with hangers, not by boiler or its accessories. refer to ANSI Z223.1 (or CAN/CGA B149.1 orB149.2 for Canadian installations). 3. Purge all air from gas supply piping. 4. Before placing boiler in operation, check boiler and its gas connection for leaks. Do not check for gas leaks with an open flame — use bubble test. Failure to use bubble test or check for gas leaks can cause severe personal injury, death or substantial property damage. 38 5. Use pipe dope compatible with propane gases. Apply sparingly only to male threads of pipe joints so that pipe dope does not block gas flow. a pressure drop through the line of 0.3" w.c..For additional gas pipe sizing information, 2. Inlet pressure required at gas valve inlet: maximum 13" w.c. minimum 4" w.c. 3. Install 100% lockup gas pressure regulator in supply line if inlet pressure exceeds 13" w.c. Adjust for 13" w.c. maximum. Propane Gas: 1. Contact gas supplier to size pipes, tanks and 100% lockup gas pressure regulator. a. Close manual main shutoff valve during any pressure testing at less than 13" w.c. 2. Adjust propane supply regulator provided by gas supplier for 13" w.c. maximum pressure. b. Disconnect boiler and gas valve from gas supply piping during any pressure testing greater than 13" w.c. 3. Inlet pressure required at gas valve inlet: maximum 13" w.c. minimum 4" w.c. Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Always use a wrench on the manifold to prevent it from twisting when installing or removing external gas piping. Failure to do so could damage the blower housing assembly, resulting in a leakage of Service valve (by others) Figure 17 Gas supply connection to GV boiler gas manifold Table 3 Pipe capacity for 0.60 specific gravity natural gas Ground joint union (by others) ½" NPT Blower housing cover Manifold Gas valve Drip leg (by others) Nipple length must provide at least 3 inches between the cap and tee, per ANSI Z223.1. Outlet hex fitting Gas valve outlet hex fitting is a LEFTHAND thread. 85031 Capacity of pipe for pipe size of: (Capacity in cubic feet gas per hour) Gas pipe length (feet) ½" ¾" 1" 1¼" 1½" 10 20 30 40 50 75 100 150 132 92 73 63 56 45 38 31 278 190 152 130 115 93 79 64 520 350 285 245 215 175 150 120 1050 730 590 500 440 360 305 250 1600 1100 860 760 670 545 460 380 Part number 550-141-850/0699 39 GOLD GV Water boiler series 3 — manual VI Field wiring Electrical installation must comply with: National Electrical Code and any other national, state, provincial or local codes or regulations. In Canada, C.S.A. C22.1 Canadian Electrical Code Part 1, and any local codes. Wiring must be N.E.C. Class 1. If original wiring as supplied with boiler must be replaced, use only type 90 °C wire or equivalent. Boiler must be electrically grounded as required by National Electrical Code ANSI/NFPA 70-latest edition. Wiring connections Thermostat(s) Install on inside wall away from influences of drafts, hot or cold water pipes, lighting fixtures, television, sunrays, or fireplaces. Follow instructions with thermostat. If it has a heat anticipator, set heat anticipator in thermostat to match power requirements of equipment connected to it (ignition control and gas valve, zone valve contacts, etc.). Wiring diagram on boiler gives setting for standard equipment (ignition control and gas valve). Thermostat wires are labeled "T-T" on boiler. Remove label before connecting as shown in Figure 18. Route this wiring through the hole in the upper left side jacket. For zoned systems, substitute the zone valve end switches or circulator relay contacts for the thermostat contact shown in Figure 18. 40 When using three-wire zone valves, take care to avoid miswiring. This can impose an additional 24 volts across the boiler control circuitry. The boiler control module will sense this problem and lockout. It will flash the POWER and TSTAT CIRC lights to indicate the problem. See label on control module for explanation of lockout conditions. To verify before connecting to boiler, disconnect field thermostat wires at boiler. Place a voltmeter across the leads. Then watch the voltmeter as each zone is activated (by activating zone thermostat). There should never be a voltage reading across the two leads coming to the boiler. If you see a voltage reading, one or more zone valves is miswired. Junction Box (furnished) Mount the 2 x 4 junction box on the left side of the boiler as shown on page 3 of this manual and in other illustrations. Fused disconnect or service switch (15 amp. recommended) may be mounted on this box. For those installations with local codes which prohibit installation of fused disconnect or service switch on boiler, install a 2 x 4 cover plate on the boiler junction box and mount the service switch remotely as required by the code. Connect 120 VAC power wiring as shown in Figure 18. Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Figure 18 Field wiring connections — service switch and thermostat (or end switch) provided by installer Field wiring 120 VAC Hot Service switch Neutral Ground (not provided) Thermostat or end switch (not provided) Service switch (not provided) Thermostat or end switch Factory wiring Ground screw Black White Green Wire nuts Black (not provided) Black Thermostat leads, through jacket left side Junction box, boiler left side 85028 For your safety, turn off electrical power supply at Wiring must be N.E.C. Class 1. service entrance panel before making any electrical connections to avoid possible electric shock hazard. Failure to do so can cause severe personal injury or death. Watch polarity of the circuit when connecting the 120 VAC power wiring. If the polarity is switched, the boiler control module will lockout. The control module will flash the POWER light to indicate this problem. See Troubleshooting, manual Section XI. Part number 550-141-850/0699 If original wiring as supplied with boiler must be replaced, use only type 105 °C wire or equivalent. Boiler must be electrically grounded as required by National Electrical Code ANSI/NFPA 70-latest edition. 41 GOLD GV Water boiler series 3 — manual VIIa Start-up — overview ❏ Determine if water treatment will be needed to compensate for water hardness or pH. ❏ Obtain propylene/glycol antifreeze if freeze protection is required. Glycol must be propylene glycol only, and special requirements may apply when using glycol. ❏ Check for gas leaks (and verify propane odorant level). ❏ Fill system with water and purge air. Verify water piping is leak-free. ❏ Study boiler operating instructions, Section IX. Then start boiler. ❏ Verify water piping, gas piping and vent system are leak-free. Verify igniter operation. ❏ For installations at altitudes over 5,500 feet above sea level, measure gas valve outlet pressure and adjust if required (see also Section IId). VIIb Start-up — preparation Do not use petroleum-based cleaning or sealing compounds in boiler system. Severe damage to boiler will occur, resulting in substantial property damage. Verify water chemistry Consult local water treatment companies for unusually hard water areas (above 7 grains hardness) or low pH water conditions (below 7.0). Eliminate all system leaks. Continual fresh makeup water will reduce boiler life. Minerals can build up in sections, reducing heat transfer, overheating cast iron, and causing section failure. 1. Determine antifreeze quantity according to system water content. Boiler water content is listed in Table 12 on page 95. Remember to include expansion tank water content. 2. Follow antifreeze manufacturer's instructions. Freeze protection (when used) Use antifreeze made especially for hydronic systems. Inhibited propylene glycol is recommended. Do not use ethylene glycol, automotive or undiluted antifreeze. Severe personal injury or death can result. 42 3. A 50% solution of propylene glycol/water provides maximum protection to about -30 °F. 4. Local codes may require back flow preventer or actual disconnect from city water supply. 5. When using antifreeze in a system with automatic fill, install a water meter to monitor water makeup. Glycol will leak first at any leak spot. Added water will dilute the antifreeze, reducing the freeze protection level. Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance VIIb Start-up — preparation Verify gas/air orifice plate The proper orifice plate must be used. Failure to do so will cause severe personal injury, death or substantial property damage. 1. Remove the jacket front panel. 2. Read the boiler size written on the gas/air orifice label tab, verifying the correct size. See Figure 5b for details. 3. The orifice plate must be plain aluminum for natural gas. For propane gas, the exposed tab of the plate should be red. 4. Replace the orifice plate if necessary, following the guidelines of Section IIc in this manual. Check for gas leaks Before starting the boiler, and during initial operation, smell near the floor and around the boiler for gas odorant or any unusual odor. Do not proceed with start-up if there is any indication of a gas leak. Repair any leak at once. Failure to comply could result in severe personal injury, death or substantial property damage. Propane boilers only — Your propane supplier mixes an odorant with the propane to make its presence detectable. In some instances, the odorant can fade, and the gas may no longer have an odor. Before startup (and periodically thereafter), have the propane supplier verify the correct odorant level in the gas. Failure to comply could result in severe personal injury, death or substantial property damage. (cont.) 3. Purge air from system: a. Connect a hose to the purge valve (shown in suggested piping illustrations in this manual). Route hose to an area where water can drain and be seen. b. Close the boiler or system isolation valve between the purge valve and fill connection to the system. c. Close zone isolation valves. d. Open quick-fill valve on cold water makeup line. e. Open purge valve. f. One zone at a time, open the isolation valves. Allow water to run through the zone, pushing out the air. Run until no noticeable air flow is present. Close the zone isolation valves and proceed with the next zone. Follow this procedure until all zones are purged. g. Close the quick-fill water valve and purge valve and remove the hose. Open all isolation valves. Watch that system pressure rises to correct cold-fill pressure. h. After the system has operated for a while, eliminate any residual air by using the manual air vents located throughout the system. i. Relieve any residual air in the boiler piping using the manual air vent (page 3, item i) installed on the boiler supply piping. j. If purge valve is not installed, open manual air vents in system one at a time, beginning with lowest floor. Close vent when water squirts out. Repeat with remaining vents. 4. Open automatic air vent (diaphragm- or bladdertype expansion tank systems only) one turn. Inspect system water piping After filling the boiler and system with water, inspect all piping throughout the system for leaks. If found, repair immediately. Repeat this inspection after the boiler has been started and the system has heated up. Leaks must be repaired at once. Failure to do so can damage Fill the system with water the boiler, resulting in substantial property damage. 1. Close manual and automatic air vents and boiler drain cock. Do not use petroleum-based 2. Fill to correct system pressure . Correct pressure will vary with each application. Typical cold water fill pressure for a residential system is 12 psi. Severe damage to boiler will occur, resulting in substantial property damage. Part number 550-141-850/0699 cleaning or sealing compounds in boiler system. 43 GOLD GV Water boiler series 3 — manual VIIc Start-up — read Section IX Boiler sequence of operation Lighting instructions Manual Section IX contains information about the operation of the boiler and controls. Read this information, including the Sequence of operation diagram, to familiarize yourself with the normal operation of the control system. Note also the lockout conditions of the boiler control module, found on the control cover label. Section IX also includes a Lighting instruction procedure for each gas valve used on the GV boiler (Figure 25 or 26). Select the correct lighting instruction by reading the model number on the gas valve (can be viewed with the boiler front jacket panel removed). Use only the Lighting instruction procedure for this model gas valve. Component operating information Manual Section XI , Troubleshooting includes additional information about the operation of specific boiler components. VIId Start-up — to operate boiler Perform final checks before starting boiler Read manual Section IX. Select the correct Lighting instruction procedure (Figure 25 or 26) based on the gas valve installed in the boiler. Start the boiler Follow the correct Lighting instruction from Section IX to start the boiler. See Section VIIe if boiler fails to start. Verify the boiler and system are full of water. Verify the start-up preparation procedures of Section VIIb have been completed. Do not use petroleum-based cleaning or sealing compounds in boiler system. Severe damage to boiler will occur, resulting in substantial property damage. Verify that the gas/air orifice plate has been checked (and replaced if necessary) per manual Section IIc. Complete this procedure before starting boiler. Using an incorrect gas/air orifice plate will result in severe personal injury, death or substantial property damage. 44 Check system and boiler Eliminate all system leaks . Continual fresh makeup water will reduce boiler life. Minerals can build up in sections, reducing heat transfer, overheating cast iron, and causing section failure. Venting system must be sealed gas-tight to prevent flue gas spillage and carbon monoxide emissions which could result in severe personal injury or death. Inspect vent system per following. 1. Check system piping for leaks. If found, shut down boiler and repair immediately. Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance VIId Figure 19 Start-up — operate boiler Check for igniter glow by looking into observation port on front of blower housing. (cont.) 2. Vent air from system using manual vents. Air in the system will interfere with circulation and cause heat distribution problems and noise. 3. Inspect vent system thoroughly. Check for gastight seal at every connection and seam. 4. Check around the boiler for gas odor following the procedure of Section VIIb of this manual. If you discover evidence of any gas leak, shut down the boiler at once. Find the leak source with bubble test and repair immediately. Do not start boiler again until corrected. Failure to comply could result in severe personal injury, death or substantial property damage. 5. Verify igniter operation — Look through blower observation port (see Figure 19). Access the blower by removing the boiler jacket front panel. Observation port You should see the igniter glow, particularly during the igniter warm-up period of the control cycle. 85034 6. After successful operation of boiler and verification of system (water, vent and gas piping), proceed to the Check-out procedure, Section VIII of this manual. VIIe Start-up — if boiler doesn’t start . . . Check for: 1. Loose connections, blown fuse or service switch off? 2. High limit switch set below boiler water temperature? 3. Thermostat set below room temperature? 4. Gas not turned on at meter or boiler? 5. Incoming gas pressure less than 4" w.c.? If none of the above corrects the problem, refer to Troubleshooting, manual Section XI. Part number 550-141-850/0699 45 GOLD GV Water boiler series 3 — manual VIIf Start-up — altitude over 5,500 feet ONLY Apply the following only when: • Altitude is over 5,500 feet above sea level. • You have obtained a high altitude kit (with tools needed) and installed high altitude air pressure switch per the instructions of manual Section IId. • Boiler has started correctly, following procedures on previous pages. Figure 20 Tools required for gas valve outlet pressure measurement You will need the tools shown in Figure 20. Adjust the gas valve outlet pressure only if required as described in the following instructions. Connect and adjust manometer 1. Remove boiler jacket top and front. 2. Close manual gas supply valve and turn off electrical power to boiler. 3. Using 3/16" allen wrench, remove outlet pressure tap plug from gas control and save plug (Figure 21). 4. Install 1/8" NPT-to-hose barb fitting in gas control outlet pressure tap as shown (Figure 21). 5. Position and zero manometer per manufacturer’s instructions. • Manometer must have at least 6" of tubing above the fluid level or fluid may be drawn into the gas control. If manometer fluid is drawn into gas control body, gas control must be replaced. Fluid in valve will cause it to malfunction, possibly resulting in severe personal injury, death or substantial property damage. 6. Disconnect tube from hose barb on gas control vent tap. Connect tube end to tee hose fitting as shown in Figure 21. Then add length of hose from tee hose fitting to gas control vent tap. 7. Connect positive side manometer hose to top of the tee hose fitting (Figure 21). 8. Connect negative side manometer hose to hose barb fitting installed in gas control outlet pressure tap (Figure 21). 85025 1 2 3 4 5 6 7 8 5. 6. 7. Check Gas Control Set Point 1. Open manual gas valve and turn on electrical power to boiler. 2. Start boiler and allow boiler to run for 5 minutes. 3. Read manometer. This is the gas control outlet pressure set point. If set point is between – 0.1" w.c. and – 0.3" w.c. go to step 7. 4. If gas control set point is not between – 0.1" w.c. and – 0.3" w.c. remove cap on adjustment tower of gas control. • For White-Rodgers Model 36C valves, use 46 8. 9. 10. 11. 12. 13. U-tube manometer with tubing - Manometer provides a fine scale by slanting the manometer (Dwyer Model 1227 recommended). Tee hose fitting (provided in high altitude kit). ³⁄₁₆" allen wrench. ¹⁄₈" N.P.T.-to-hose barb fitting and wrench for same. (Fitting is provided in high altitude kit.) Phillips screwdriver. ¹⁄₄" flat head screwdriver. Special tool for gas control adjustment cap removal for White-Rodgers 36C valves (provided in high altitude kit). Pliers. pliers and special tool provided (Figure 20, items 7 and 8). Turn gas control adjustment screw counter clockwise to lower gas control set point to – 0.2" w.c. Reinstall cap to gas control adjustment tower (with special tool for 36C valves). Cycle boiler off and on several times to verify gas control set point. If set point does not remain between - 0.1" w.c. and – 0.3" w.c., readjust as necessary. Close manual gas supply valve and turn off electrical power to boiler. Remove 1/8" NPT-to-hose barb fitting in outlet pressure tap of gas control. Apply pipe sealant to outlet pressure tap plug and reinstall using 3/16" allen wrench. Remove tee hose fitting and added tube. Reinstall hose on gas control vent tap hose barb. Open manual gas supply valve and turn on electrical power to boiler. Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Figure 21 Carefully connect manometer to gas valve as shown, following instructions on opposite page. Cap on adjustment tower Gas control outlet pressure tap — Remove allen screw from gas control outlet pressure tap and install hose barb as shown. At Least 6 Inches Manifold + Robertshaw Model 7200DERN-680 Gas control vent tap Add tee hose fitting as shown Gas outlet piping Add hose from gas control vent tap to tee hose fitting White-Rodgers Model 36E66-302 Gas control outlet pressure tap — Remove allen screw from gas control outlet pressure tap and install hose barb as shown. Gas control vent tap Part number 550-141-850/0699 Existing hose to gas control vent tap hose barb — Remove from gas control vent tap and connect to end of tee as shown 85026 47 GOLD GV Water boiler series 3 — manual VIIIa Check-out procedure — overview Overview of this ❏ Perform the checklist following to ensure boiler is operating correctly. section ❏ Fill in the Installation and service certificate at the end of the checklist. VIIIb Check-out procedure — checklist Check off steps as ! Boiler and heat distribution units filled with water? completed ! Automatic air vent, if used, open one full turn? ! Air purged from system? ! Air purged from gas piping? Piping checked for leaks? ! Is proper orifice plate installed? Refer to manual Section IIc to check size and fuel type. Proper orifice plate must be used. Failure to do so will cause severe personal injury, death or substantial property damage. ! Followed operating instructions on boiler or in manual Section VII for proper start-up? ! Is igniter glow visible? Refer to Verify igniter operation, manual Section VIId, step 5. ! Inspect vent system for leaks. Verify vent (and air) piping are functional and unobstructed. ! Test limit control — While burner is operating, move indicator on limit control below actual boiler water temperature. Blower and burner should go off while circulator continues to operate. Raise setting on limit control above boiler water temperature and burner should reignite. ! Test additional field-installed controls — If boiler has a low water cutoff, additional high limit or other controls, test for operation as outlined by manufacturer. Burner should be operating and should go off when controls are tested. When controls are restored, boiler should restart. ! Test ignition system (control module): a. b. c. d. 48 Connect voltmeter to gas valve terminals. Turn off manual gas valve. Set thermostat to call for heat. Control module will begin purge cycle, then activate igniter. Igniter will glow for approximately 20 seconds. Near end of 20 seconds, 24 VAC will show at gas valve for approximately 6 seconds and then Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance VIIIb Check-out procedure — checklist e. (cont.) return to 0 VAC. Control will attempt ignition two more times, increasing igniter time to 30 seconds for these attempts. The control will then lockout, flashing the POWER and FLAME lights. To restart system, follow Lighting instructions on boiler or in manual Section IX. (Control will reset after power has been off for at least 45 seconds.) ! Set limit control(s) to system temperature requirements. Adjust balancing valves and controls to provide design temperature to system. ! For multiple zones, adjust flow so it is about the same in each zone. ! Verify thermostat heat anticipator (if available) set properly? Refer to Field wiring, manual Section VI, Thermostat(s). ! Cycle boiler with thermostat — Raise to highest setting and verify boiler goes through normal start-up cycle. Lower to lowest setting and verify boiler goes off. ! Measure natural gas input: a. b. c. d. Operate boiler 10 minutes. Turn off other appliances. At natural gas meter, measure time (in seconds) required to use one cubic foot of gas. 3600 x 1000 Calculate gas input: = Btuh number of seconds from step c ! ! ! ! e. Btuh calculated should approximate input rating on boiler rating label. Observe several operating cycles for proper operation. Set room thermostat to desired room temperature. Fill in Installation and service certificate below? Review all instructions shipped with this boiler with owner or maintenance person. Return instructions to envelope and give to owner or place in pocket inside front panel in boiler. Installation and service certificate Boiler model __________________ Measured Btuh input ____________ Installer ________________________ (company) Series __________ ! ! ! ! CP number ___________ Date installed _______________ Installation instructions have been followed. Check-out sequence has been performed. Above information is certified to be correct. Information received and left with owner/maintenance person. ________________________________ (address) ______________________________ (phone) _____________________________________ (installer’s signature) Part number 550-141-850/0699 49 GOLD GV Water boiler series 3 — manual IXa Operation — overview Overview of this ❏ The GCM (control module) is equipped with five indicator lights, used to show normal and problem situations. See Figure 22 for the normal sequence section of operation of the boiler and control, and the status of the lights at each stage. For explanation of the lockout conditions of the GCM lights, see manual Section X, Troubleshooting. ❏ Figure 23 shows the ladder wiring diagram for the GV series 3 boiler. ❏ Figure 24 is the schematic wiring diagram, showing the destination of each of the wire harnesses attached to the control module. ❏ Figure 25 is the Lighting instruction sheet for boilers equipped with Robertshaw model 7200DERN valves. ❏ Figure 26 is the Lighting instruction sheet for boilers equipped with WhiteRodgers model 36E valves. 50 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance IXb Operation — sequence Figure 22 Ignition control module sequence of operation — status light indications POWER Steps TSTAT CIRC Call for heat? LIMIT PRESS SWITCH FLAME Timing (Following step 8, cycle goes back to step 1.) 1. Standby · Waiting for call for heat NO — YES — YES — YES 35 sec YES 6 sec YES — YES — NO 30 sec 2. Call for heat · · Circulator on Blower on 3. Limit circuit · · Limit controls closed Block switch contacts closed 4. Pressure circuit · · Pressure switch contacts closed Igniter heating 5. Flame proven · · · Gas valve open Ignitor remains on Boiler producing heat 6. Limit cycle · · Limit circuit open Gas valve closed 7. Flame outage * · · Flame out Boiler recycles 8. Thermostat satisfied · · Circulator off Blower postpurge or = "ON" = "OFF" * If flame is not proven in 4 seconds, boiler recycles 2 times to retry for ignition before going into lockout. Recycle igniter timing is 30 seconds. Postpurge and prepurge are performed on every cycle. In event of lockout, ignition control will automatically restore sequence of operation after either: 1 hour waiting period. Opening and closing of thermostat circuit. Removal of 120 VAC power for at least 45 seconds. 85050 Part number 550-141-850/0699 51 GOLD GV Water boiler series 3 — manual IXb Operation — wiring diagrams Figure 23 Ladder wiring diagram 120 VAC Gnd Service switch (not provided) Igniter Electrical shock hazard — can cause severe injury or death. Disconnect power before installing or servicing. Blower motor All contacts are shown without power applied. System circulator Ladder diagram legend Control module 120 VAC section 120 VAC hot field wiring 120 VAC neutral field wiring Bypass circulator 24 VAC field wiring 120 VAC hot factory wiring 120 VAC 120 VAC neutral factory wiring Low voltage factory wiring 24 VAC Ground connectors Notes 1. 2. Power All wiring must be installed in accordance with: a. U.S.A. — N.E.C. and any other national, state, or local code requirements. b. Canada — C.S.A. C22.1 C.E.C. Part 1 and any other national, provincial, or local code requirements. a. U.S.A. — N.E.C. Class 1. b. Canada — C.S.A. C22.1 C.E.C. Part 1. If any of the original wire as supplied with the appliance must be replaced, use type 90 °C or its equivalent. 4. Thermostat anticipator setting (single zone): 0.1 AMP + Gas valve current 5. For multiple zoning, use either zone valves or circulators. Refer to the component manufacturer's instructions and this manual for application and wiring suggestions. 52 Refer to control component instructions packed with the boiler for application information. Gas valve Tstat–Circ Block temp limit switch Water temp limit switch Limit All wiring must be: 3. 6. Thermostat (not provided) Air pressure switch Press switch Flame Flame sensor Water temp sensor Control module low voltage section 85030 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Schematic wiring diagram 120 VAC Hot Field wiring Figure 24 Service switch Ground Neutral (not provided) Thermostat or end switch (not provided) Service switch (not provided) Thermostat or end switch Plug-in connectors White Red Factory wiring Ground screw 120 VAC hot/neutral Low voltage (colors vary) Black White Green (not provided) Wire nuts Black Black Thermostat leads, through jacket left side Junction box, boiler left side Ground connectors W G B W W G B B R R BR Red hose White hose R Air pressure switch Transformer System circulator Bypass circulator R BL W W G B B W W W G G G B B B BL Y Y B G B GCM FLAME PRES SWITCH LIMIT POWER TSTAT CIRC B W Block temperature limit switch R W Y Y BR R B B G Water temperature sensor B BL BL Blower motor Gas valve Y 85029 Y Water temperature limit switch Part number 550-141-850/0699 W Hot surface igniter B 53 GOLD GV Water boiler series 3 — manual IXc Figure 25 Operation — lighting instructions Lighting instructions for boiler equipped with Robertshaw model 7200DERN gas valve FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. C. Use only your hand to depress and move Selector arm on gas valve. Never use tools. If the arm will not depress or move by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. B. Before OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. See below. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control, which has been under water. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • • Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. OPERATING INSTRUCTIONS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. STOP! Read the safety information above on this label. Set the thermostat to lowest setting. Turn off all electrical power to the appliance. Remove jacket top panel. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. Depress Selector arm slightly and move left to OFF. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step. Depress Selector arm slightly and move right to ON. Turn on all electric power to the appliance. Set thermostat to desired setting. If the appliance will not operate, follow the instructions "TO TURN OFF GAS TO APPLIANCE" below and call your service technician or gas supplier. Replace jacket top panel. Robertshaw gas valve model 7200DERN Selector arm 85020 NOTE: Selector arm cannot be moved to OFF unless arm is pushed in slightly. DO NOT force. TO TURN OFF GAS TO THE APPLIANCE 1. Set the thermostat to lowest setting. 2. Turn off all electric power to the appliance if service is to be performed. 3. Remove jacket top panel. 4. Depress Selector arm slightly and move left to OFF. Do not force. 5. Replace jacket top panel. 54 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Figure 26 Lighting instructions for boiler equipped with White-Rodgers model 36E gas valve FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. C. Use only your hand to turn the Control knob on gas valve. Never use tools. If the knob will not turn by hand, don't try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion. B. Before OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. See below. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control, which has been under water. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • • Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. OPERATING INSTRUCTIONS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. STOP! Read the safety information above on this label. Set the thermostat to lowest setting. Turn off all electrical power to the appliance. Remove jacket top panel. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. Turn Gas control knob to OFF. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step. Turn Gas control knob to ON. Turn on all electric power to the appliance. Set thermostat to desired setting. If the appliance will not operate, follow the instructions "TO TURN OFF GAS TO APPLIANCE" below and call your service technician or gas supplier. Replace jacket top panel. White-Rodgers gas valve model 36E Gas control knob 85022 Position indicator TO TURN OFF GAS TO THE APPLIANCE 1. Set the thermostat to lowest setting. 2. Turn off all electric power to the appliance if service is to be performed. 3. Remove jacket top panel. 4. Turn Gas control knob to OFF. 5. Replace jacket top panel. Part number 550-141-850/0699 55 GOLD GV Water boiler series 3 — manual Xa Service and maintenance — overview Overview of this section ❏ Review Table 4 with the owner to advise of the need for annual start-up and service by a qualified technician. ❏ Review Table 4 with the owner, explaining the maintenance required and procedures to follow. ❏ The following pages of this section provide detailed instructions for each of the service and maintenance items given in Table 4. ❏ Do not attempt the service and maintenance items listed without reviewing the detailed information on the following pages. Follow the Service and maintenance procedures given throughout this manual and in component literature shipped with the boiler. Failure to perform the service and maintenance could result in damage to the boiler or system. Failure to follow the directions in this manual and component literature could result in severe personal injury, death or substantial property damage. 56 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Xb Service and maintenance — schedule Table 4 Service and maintenance schedules Service technician Owner maintenance (see following pages for instructions) (see following pages for instructions) ANNNUAL START-UP Inspect: • • • • • • • Any problems reported by owner Boiler area Air openings Flue gas vent Boiler heating surfaces Water piping Condensate drain system Service: • Check boiler area Daily • Check air openings • Check pressure gauge • Check boiler interior piping • Check venting system Monthly • Check air vents • Check condensate drain system • Lubricate blower motor • Lubricate any circulators requiring oil • Check relief valve Start-up: • Perform start-up per manual Check/test: • • • • Check gas piping for leaks Check cold fill & operating pressures Check temperature mixing system Check/maintain components - vents, limits, expansion tank, gauges, igniter • Inspect & operate relief valve • Test low water cutoff (if used) Periodically • Clean vent termination/air intake screens • Oil blower motor Every 6 months • Operate relief valve Review: • Review maintenance procedures with owner Part number 550-141-850/0699 End of season • Shut down procedure 57 GOLD GV Water boiler series 3 — manual Xc Service & maintenance — annual start-up Annual start-up only by qualified service technician The boiler should be inspected and started annually, at the beginning of the heating season, only by a qualified service technician. In addition, the maintenance and care of the boiler designated in Table 4 and explained on the following pages must be performed to assure maximum boiler efficiency and reliability. Failure to service and maintain the boiler and system could result in equipment failure. Annual start-up — Reported problems inspect Inspect any problems reported by owner and correct before proceeding. Boiler area 1. Verify that boiler area is free of any combustible materials, gasoline and other flammable vapors and liquids. 2. Verify that boiler area (and air intake) is free of any of the contaminants listed on page 13 of this manual. If any of these are present in the boiler intake air vicinity, they must be removed. If they cannot be removed, install combustion air piping to the boiler in accordance with the appropriate venting supplement. Air openings 1. Verify that combustion and ventilation air openings to the boiler room and/or building are open and unobstructed. Check operation and wiring of automatic combustion air dampers, if used. 2. Verify that boiler vent discharge and air intake are clean and free of obstructions. Flue gas vent system (and air inlet piping) 1. Visually inspect entire flue gas venting system (and air piping, if installed) for blockage, deterioration or leakage. Repair any joints that show signs of leakage in accordance with vent manufacturer’s instructions. When air is ducted to boiler, verify that air inlet hose is connected and properly sealed. Failure to inspect for the above conditions and have them repaired can result in severe personal injury or death. Boiler heating surfaces 1. Obtain a GV gasket replacement kit. This kit contains four gaskets — igniter gasket, vent starter tee gasket, inspection port gasket, and burner gasket. Electrical shock hazard — Turn off power to the boiler before any service operation on the boiler except as noted otherwise in this instruction manual. Failure to turn off electrical power could result in electrical shock, causing severe personal injury or death. 2. Remove the jacket top panel and jacket front panel after turning off power to the boiler. 3. Remove the two nuts retaining the flueway inspection port cover (page 3, item g). Remove the flueway inspection port cover. 4. Inspect the boiler vent outlet area and heating surfaces by looking through the opening. 5. If the boiler flueways show accumulation of soot, follow Cleaning boiler heating surfaces in this manual section to remove the blower housing and clean the boiler. If there is evidence of a large accumulation of rusty scale deposits, check the temperature mixing system. 6. Replace the flueway inspection port cover. 58 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Annual start-up — Water piping inspect 1. Check the boiler interior piping and all system piping for signs of leaks. 2. Repair any leaks before proceeding. Eliminate all system leaks. Continual fresh makeup water will reduce boiler life. Minerals can build up in sections, reducing heat transfer, overheating cast iron, and causing section failure. Do not use petroleum-based cleaning or sealing compounds in boiler system. Severe damage to boiler will occur, resulting in substantial property damage. Condensate drain system 1. Inspect the condensate trap hose for deterioration. 2. Check for any obstructions in the trap hose by squeezing the tubing. 3. If there is any doubt the condensate drain system is flowing freely, remove the clamp and hose from the bottom of the vent starter tee. Slide a funnel outlet into the trap hose and pour water through. It should exit at the termination of the condensate drain line. 4. If the owner’s monthly inspection of the condensate drain system has indicated a tendency for the trap to run dry, install a condensate drain line check valve kit, available through your Weil-McLain distributor. See installation instructions for check valve kit in this manual section. Annual start-up — Blower motor (Figure 27) service 1. With boiler power OFF, place a few drops of S.A.E. Figure 27 Blower motor 20 motor oil in each of the two oil cups. Use only S.A.E. 20 motor oil to lubricate the blower motor. Do not use universal household oils. Motor could be damaged, resulting in possible severe property damage. Oiled-bearing circulators Oil cup 1. Both of the circulators installed in the boiler are waterlubricated. No oiling is required. 2. Check other circulators in the system. Oil any circulators requiring oil, following circulator manufacturer’s instructions. Over-oiling will damage the circulator. Oil cup 85037 Annual start-up — Start-up procedure start-up 1. Follow the instructions in manual Section VII. 2. Verify cold fill pressure is correct and that fill system is working properly. 3. Verify antifreeze level (if used) is at the right concentration and that inhibitor level is correct. 4. Check gas piping, per manual Sections V and VIb, verifying no indications of leakage and all piping and connections are in good condition. 5. Read the Lighting instructions (Figure 25 or 26 of this manual or on boiler label) applying to the boiler (ensuring the instruction applies to the gas valve installed in the boiler). 6. Start the boiler following the Lighting instructions and manual Section VIId. Part number 550-141-850/0699 59 GOLD GV Water boiler series 3 — manual Xc Service & maint. — annual start-up (cont.) Annual start-up — Gas piping check/test 1. Sniff near floor and around boiler area for any indication of a gas leak. 2. Test gas piping using bubble test, per Section V of this manual, if there is any indication of a leak. Cold fill and operating pressures 1. While the system is cold, note the pressure reading on the boiler pressure/temperaure gauge. Verify that cold fill pressure is correct. 2. Watch the pressure as the boiler and system heat up to ensure pressure rise is normal. Too high a rise would indicate a waterlogged or undersized expansion tank. Temperature mixing system 1. Carefully check the temperature of the system return piping as it passes through the boiler jacket and on the return pipe inside the boiler jacket just before it enters the boiler sections. You may do this with a surface pyrometer or by lightly touching the piping with your fingers. To avoid potential of severe burn — Do not rest hands on or grasp pipes. Use a light touch only. Return piping may heat up quickly. 2. The temperature of the water entering the boiler sections should quickly heat up to about 130 °F, being considerably hotter than the return water from the system. 3. This is accomplished with the two internal boiler circulators. The Bypass circulator (page 2, item 7) takes hot water from the boiler supply outlet and blends it with return water. The System circulator (page 2, item 6) slows down to aid in raising the return temperature entering the sections. 4. If the temperature mixing system does not work correctly, check the two circulators to be sure they are flowing water. If the circulators are operating normally but the temperature mixing system does not maintain water at the enterance to the boiler sections at 130 °F, you may need to replace the boiler control module or water temperature sensor (page 2, item 8). Air vents and air elimination Figure 28 1. Inspect automatic air vents (if used). Also inspect air separators to ensure they are operational. A 2. The cap must be unscrewed one turn to allow air to escape. B Automatic air vent 3. See Figure 28. If the air vent is leaking, remove cap A and briefly push valve B and then release to clean the valve seat. 4. Replace cap A by twisting all the way onto valve B and then unscrewing one turn. Limit controls and cutoffs 1. Inspect and test the boiler limit control. Verify operation by turning control set point below boiler temperature. Boiler should cycle off. Return dial to original setting. 2. Inspect and test additional limit controls or low water cutoffs installed on system. 60 85036 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Annual start-up — Expansion tank check/test 1. Expansion tanks provide space for water to move in and out as the heating system water expands due to temperature increase or contracts as the water cools. Tanks may be open-, closed- or diaphragm- or bladder-type. See Section III of this manual for suggested best location of expansion tanks and air eliminators. Open-type — Located above highest radiator or baseboard unit, usually in the attic or closet. Has a gauge glass and overflow pipe to a drain. Closed-type — Welded gas tight and located above boiler. Tank is partially filled with water, leaving an air cushion for expansion. • Make sure this type of tank is fitted with a tank fitting, such as the B & G Tank-Trol or Taco Taco-Trol. This fitting reduces gravity circulation of air-saturated tank water back to the system and prevents the air from bubbling up through the water as it returns from the system. • Do not use automatic air vents in systems with closed-type tanks. The air will escape from the system instead of returning to the tank. Eventually, the tank will waterlog and no longer control pressurization. The boiler relief valve will weep frequently. Diaphragm- or bladder- type — Welded gas tight with a rubber membrane to separate the tank pressurizing air and the water. May be located at any point in the system, but most often found near the boiler. • Systems with this type of expansion tank require at least one automatic air vent, preferably located on top of an air eliminator, as shown in examples in manual Section III. 2. If relief valve has tended to weep frequently, the expansion tank may be waterlogged or undersized. Closed-type tank — Tank is most likely waterlogged. Install a tank fitting if not already installed. Then check fill level per fitting manufacturer’s instructions. If fill level is correct, check tank size against manufacturer’s instructions. Replace with a larger tank if necessary. Diaphragm- or bladder type — First, check tank size to be sure it is large enough for the system. If size is too small, add additional tank(s) as necessary to provide sufficient expansion. If tank size is large enough, remove tank from system and check charge pressure (usually 12 psig for residential applications). If tank won’t hold pressure, membrane has been damaged. Replace tank. Gauges Figure 29 Igniter observation port in blower 1. Boiler pressure/temperature gauge — Inspect gauge and check whether readings are reasonable. Replace if any signs of leakage from case or improper readings. 2. System gauges (if installed) — Inspect and check readings of other gauges in system. Igniter 1. Verify igniter operation — Look through blower observation port (see Figure 29). Access the blower by removing the boiler jacket front panel if not already removed. Part number 550-141-850/0699 Observation port 85034 61 GOLD GV Water boiler series 3 — manual Xc Service & maint. — annual start-up Annual start-up — Boiler relief valve check/test 1. Inspect the relief valve and lift the lever to verify flow Figure 30 (cont.) Relief valve as in the following warnings, excerpted from a relief valve manufacturer’s warning label. Before operating any relief valve, ensure that it is piped with its discharge in a safe area to avoid severe scald potential. Read manual Section IIIb before proceeding further. Safety relief valves should be reinspected AT LEAST ONCE EVERY THREE YEARS , by a licensed plumbing contractor or authorized inspection agency, to ensure that the product has not been affected by corrosive water conditions and to ensure that the valve and discharge line have not been altered or tampered with illegally. Certain naturally occurring conditions may corrode the valve or its components over time, rendering the valve inoperative. Such conditions are not detectable unless the valve and its components are physically removed and inspected. This inspection must only be conducted by a plumbing contractor or authorized inspection agency — not by the owner. Failure to reinspect the boiler relief valve as directed could result in unsafe pressure build-up, which can result in severe personal injury, death or substantial property damage. 85035 Following installation, the valve lever must be operated AT LEAST ONCE A YEAR to ensure that waterways are clear. Certain naturally occurring mineral deposits may adhere to the valve, rendering it inoperative. When manually operating the lever, water will discharge and precautions must be taken to avoid contact with hot water and to avoid water damage. Before operating lever, check to see that a discharge line is connected to this valve directing the flow of hot water from the valve to a proper place of disposal otherwise severe personal injury may result. If no water flows, valve is inoperative. Shut down boiler until a new relief valve has been installed. 2. After following the above warning directions, if the relief valve weeps or will not seat properly, replace the relief valve. Ensure that the reason for relief valve weeping is the valve and not over-pressurization of the system due to expansion tank waterlogging or undersizing. Annual start-up — Review with owner owner review 1. Review the User’s information manual with the owner. 2. Emphasize the need to perform the maintenance schedule specified in the User’s information manual. 3. Remind the owner of the need to call in a licensed contractor should the boiler or system exhibit any abnormal behavior. 4. Remind the owner to follow the proper shutdown procedure and to schedule an anuual start-up at the beginning of the next heating season. 62 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Xd Service & maint. — special procedures Condensate drain line check valve kit The service procedures listed in Section IXc of this manual must only be performed by a qualified boiler service technician. Failure to comply could result in severe personal injury, death or substantial property damage. Figure 31 Condensate drain line check valve kit, installed — Refer to kit for detailed instructions. 1. If the owner finds that flue gases frequently leak from the condensate trap hose, install the condensate drain line check valve kit. Under some circumstances a GV vent system may not produce enough condensate to keep the condensate trap full of liquid. If the trap is not full, small amounts of flue products can be emitted into the boiler room through the condensate drain line. Contact a qualified service technician to install a condensate drain line check valve kit. 2. Obtain the kit from your Weil-McLain distributor and follow the instructions included with the kit. 3. See Figure 31 for a typical installation of the check valve on the condensate drain line. Part number 550-141-850/0699 Condensate drain line check valve assembly 85032 63 GOLD GV Water boiler series 3 — manual Xd Service & maint. — special proced. (cont.) Cleaning boiler heating surfaces The service procedures listed in Section IXc of this manual must only be performed by a qualified boiler service technician. Failure to comply could result in severe personal injury, death or substantial property damage. 1. If inspection of the boiler flueways indicates the presence of soot, clean the boiler heating surfaces using the following procedure. The process requires removing the blower housing to allow spraying water through the boiler combustion chamber. Before proceeding, obtain a GV gasket replacement kit, consisting of igniter, vent starter tee, flueway inspection port and blower gaskets. To clean heating surfaces 1. Replace flueway inspection port cover (page 3, item g). 2. Remove the corrugated drain tubing from the bottom of the vent starter tee by releasing the tube clamp. To remove the blower assembly 3. Place a catch pan under the tee to catch the cleaning water. 1. Turn off boiler by turning down the thermostat. Then turn off power at the boiler service switch. Close manual gas valve on incoming gas line to boiler. 4. Spray water into the boiler combustion chamber opening. Turn off power and gas to the boiler. Failure to do so can cause severe personal injury, death or substantial property damage. Wait several minutes after boiler has stopped to allow the igniter to cool to avoid severe personal injury or death. 2. See Figure 32. 3. Disconnect: • gas tubing from gas valve outlet (NOTE that this is a left-hand thread) by rotating the hex fitting clockwise looking at the valve outlet. • pressure switch hoses. • air inlet hose. • blower motor wiring harness from control module. • igniter harness connected to igniter plug. • blower support bracket (remove screw securing blower housing to bracket — on left side of blower housing). • ground wire. 4. Remove the two igniter screws and washers. Carefully remove the igniter. Use care when handling — igniter is very brittle. DO NOT touch igniter surface with hands or expose to any greasy substances. 5. Remove nuts from studs securing blower housing to front section. 6. Grasp blower housing and pull free from studs. Turn clockwise slightly, until blower assembly can be removed safely from inside of boiler jacket. 64 7. Remove burner cone and gasket for inspection. 5. Catch the runoff water in the pan below the vent starter tee. 6. Continue process until flueways are clean. Replace blower assembly 1. Place a new blower housing gasket over the studs at combustion chamber opening. 2. Reinstall burner cone into chamber opening. 3. Position blower assembly over studs. Install nuts and tighten. 4. Install igniter and new igniter gasket. Fasten with screws and washers. Tighten only with hand-held screwdriver. DO NOT use electric or pneumatic driver. Excessive torque will damage igniter. Do not exceed 20 inch-pounds torque. 5. Connect: a. gas tubing to gas valve outlet (turning lefthand thread hex fitting counterclockwise to tighten). b. pressure switch hoses. c. hose from gas valve to gas/air manifold. d. air inlet hose. e. blower motor wiring harness to control module. f. igniter harness to igniter plug. g. blower support bracket (with screw). h. ground wire. 6. Be sure all wiring and hose connections are correct per Figure 32 and are secure on the hose barb fittings. Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Figure 32 Blower housing removal procedure Air pressure switch Blower motor wiring harness Blower support bracket Burner gasket (replace) Burner cone and ring assembly Igniter gasket (replace) NT VE MOD EL 24V 36C9 MAX60 HZ8 NE PR C RE ESSU 8 AM G - RE PS TYPE 1“ ½ 303 WC PS IG E2 0 9647 S ES PR OT PIL Igniter Gas/air orifice plate P TA Gas tubing Red pressure switch hose White pressure switch hose Inlet air hose and clamps 85040 Part number 550-141-850/0699 65 GOLD GV Water boiler series 3 — manual XIa Troubleshooting — overview Overview of this ❏ Section XIb — troubleshooting procedures. section ❏ Section XIc — procedure for checking air pressure switch. ❏ Section XId — special servicing tips (for igniter, gas valve and blower housing). ❏ Section XIe — control module. ❏ Section XIf — common problems and possible solutions. ❏ Section XIg — troubleshooting GCM indicator light conditions. Chart 1 — POWER light conditions Chart 2 — POWER and TSTAT CIRC lights flashing Chart 3 — POWER and LIMIT lights flashing Chart 4 — POWER and PRES SWITCH lights flashing Chart 5 — POWER and FLAME lights flashing Chart 6 — TSTAT CIRC light flashing by itself Chart 7 — LIMIT light flashing by itself Chart 8 — Insufficient or no heat condition 66 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance XIb Troubleshooting — procedures Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Never jumper (bypass) any device except for momentary testing as outlined in Troubleshooting charts. Severe personal injury, death or substantial property damage can result. The control module and boiler controls can malfunction if they get wet. Never try to use a control that has been flooded or wet. Replace it. Failure to comply can result in severe personal injury, death or substantial property damage. Before troubleshooting: 1. Have a voltmeter that can check 120 VAC and 24 VAC and a continuity checker. 2. Check for 120 VAC (min. 102-max.132) to boiler. 3. Make sure thermostat is calling for heat and contacts (including appropriate zone controls) are closed. Check for 24 VAC between thermostat wire nuts and ground. 4. Have an inclined manometer with 0 – 2" w.c. range. Check the following: 1. Wire connectors to control module are securely plugged in at module and originating control. 2. Hoses are properly and securely plugged in and are not damaged. VERIFY PROPER OPERA TION AFTER SER VICING. OPERATION SERVICING. Part number 550-141-850/0699 67 GOLD GV Water boiler series 3 — manual XIc Troubleshooting — air pressure switch Checking the air pressure switch Do not use manometer as shown in Figure 33 to test gas valve outlet pressure. Where instructed in this manual to check gas valve outlet pressure, follow instructions carefully, particularly regarding connection of manometer. Manometer fluid will cause permanent damage to gas valve. Severe personal injury, death or substantial property damage can result. Check switch pressure setting 1. See Figure 33. 2. Remove both air pressure switch hoses from air pressure switch. Figure 33 Connecting a manometer to check air pressure switch. DO NOT use this arrangement to check gas valve. 3. Install tees and tubing as shown in Figure 33 to inclined manometer. 4. Turn off gas valve and set thermostat to call for heat. Blower will run but burner will not ignite. Suction Pressure 5. Check for 24 VAC between both air pressure switch terminals and ground. 6. If manometer reading is at least 1.4" w.c., but there is not 24 VAC between both air pressure switch terminals and ground, replace air pressure switch. Inclined tube manometer Troubleshooting air pressure reading 1. If manometer reading is lower than 1.4" w.c. check for possible causes: • blockage in hoses. • loose blower wheel on motor shaft. • blower motor not at proper rpm. • blockage in air inlet or hose. • blockage in flue pipe or termination. • condensate trap filled w/condensate. Red White Return to normal operation 1. When pressure reading is proper and air pressure switch is operating properly, remove tees and reinstall hoses to air pressure switch. Shown with Robertshaw 7200DERN gas control 68 85027 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance XId Troubleshooting — servicing tips Igniter Wait several minutes until igniter cools down before attempting replacement. Failure to do so will cause severe personal injury. 1. Disconnect igniter from igniter wiring harness and remove igniter before removing blower assembly. 2. Replace igniter gasket if original gasket is frayed or damaged. 3. Igniter is fragile - handle with care. Do not touch igniter surface with bare hands. Body oils can cause failure of the carbide. 85060 Gas Valve Gas valve operates with a negative pressure at the outlet — approximately -0.2" w.c. — do not set gas pressure higher than this. Follow instructions in this manual carefully if testing gas valve outlet pressure. Failure to comply can result in severe personal injury or death. The gas valve outlet tapping is a lefthand thread. Rotate counterclockwise to tighten, clockwise to loosen. When replacing valve, replace only with valve listed in this manual for use with the GV boiler. Failure to comply could result in severe personal injury, death or substantial property damage. Robertshaw Model 7200DERN-680 White-Rodgers Model 36E66-302 85061 Blower Housing Do not disassemble blower housing. A fire or explosion causing severe personal injury, death or substantial property damage can result. If you suspect a problem, replace blower housing. Follow instructions in manual Section IX, Cleaning boiler heating surfaces for blower housing removal and replacement. 85062 Part number 550-141-850/0699 69 GOLD GV Water boiler series 3 — manual XIe Troubleshooting — control module Control Module Make sure ground wiring is installed per wiring diagram. Good grounding is extremely important for proper operation. Solder or water splatter between plugs and circuit board can cause improper operation of control module. Place a shield over the boiler internal controls and components during installation. Failure to comply could result in severe personal injury, death or substantial property damage. Control indicator lights — lockout modes See Charts 1 through 8 in this section for detailed troubleshooting procedures. To reset control after a lockout, turn off power at the 120 VAC service switch or turn down all thermostats. Wait 45 seconds. Then restore power or call for heat. After an over-temperature lockout (POWER and LIMIT lights flashing), the control will only reset after interruption of 120 VAC for 45 seconds. (And temperature at return water temperature sensor must be below 240 °F.) POWER light flashing alone Usually indicates reversed polarity of 120 VAC power wires. 85063 POWER and TSTAT CIRC lights flashing Usually indicates stray voltage on external thermostat circuit wires or return water temperature entering boiler sections has not reached 130 °F within 20 minutes. Non-lockout light conditions POWER and LIMIT light flashing alternately TSTAT CIRC light flashing alone Usually indicates that limit circuit failed to cut off boiler at high temperaure — return water temperature sensor has sensed water over 235 °F. Usually indicates return water temperature sensor detects water at boiler return pipe less than 40 °F. Both internal circulators will run continuously, even with no call for heat, until temperature rises. POWER and PRES SWITCH lights flashing Usually indicates pressure switch is closed when it should not be, or pressure switch failed to close within 5 minutes of blower starting. POWER and FLAME lights flashing Usually indicates control has had three unsuccessful ignition attempts or sensed flame when it shouldn’t be there. 70 LIMIT light flashing alone Usually indicates an open or shorted return water temperature sensor. Troubleshooting the GCM See Figure 34 for location of harness plug receptacles and plugs on the control module. Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Figure 34 GCM (control module) harness plug receptacle and indicator light locations. White Green White White Green Green Black Black 120 VAC N 120 VAC N White Ground 120 VAC N Black Green 120 VAC H Ground Ground 120 VAC N Ground 120 VAC H Black 120 VAC H to System circulator (long harness) 120 VAC H 120 VAC IN to Bypass circulator (short harness) 120 VAC to circulators 120 VAC to blower motor Red wires to pressure switch White 120 VAC N Blue wires to gas valve Black 120 VAC H Yellow wires to limit control and block temp switch 120 VAC to transformer Black wires to thermostat circuit 24 VAC control circuits Black leads to water temperature sensor 120 VAC IN 120 VAC to transformer 120 VAC to blower motor 24 VAC Brown Indicator lights water temp sensor 120 VAC to circulators Red POWER TSTAT CIRC LIMIT PRES SWITCH FLAME 24 VAC control circuits water temp sensor 85051 Part number 550-141-850/0699 120 VAC H Black White 120 VAC to igniter 120 VAC N 24 VAC from transformer 24 VAC from transformer 120 VAC to igniter 71 GOLD GV Water boiler series 3 — manual XIf Troubleshooting — common problems Symptom Common Causes Possible Corrections Rapid cycling — boiler turns on and off frequently Thermostat installed where drafts or heat affect reading Locate thermostat on inner wall away from heat sources or cool drafts. Heat anticipator in thermostat adjusted incorrectly Adjust thermostat per manufacturer’s instructions. Incorrect limit setting Set limit according to system needs. Maximum setting is 220˚F. Increase limit setting to decrease cycling. Insufficient water flow through boiler Check all valves to and from boiler. Return to proper setting. Confirm circulator size. Expansion tank sized too small Call qualified service technician to check expansion tank operation and size. Flooded expansion tank Call qualified service technician to check expansion tank operation. Inoperative limit control Call qualified service technician to replace limit control. Need to frequently add makeup water Leaks in boiler or piping Have qualified service technician repair leaks at once to avoid constant use of makeup water. Makeup water can cause mineral deposits which, in turn, can cause boiler section failure. Do not use petroleumbase stop-leak compounds. Black water condition Oxygen corrosion due to leaks in boiler and piping Have qualified service technician repair at once. Keep pH of water between 7.0 to 8.5. Frequent release of water through relief valve 72 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Symptom Common Causes Possible Corrections Popping or percolating noise heard in boiler Mineral deposits in sections due to constant use of makeup water Call qualified service technician to de-lime boiler, if necessary. In some cases, deposits will be too heavy to remove with de-liming procedures. Have qualified service technician repair leaks to eliminate need for constant makeup water. Incorrect pH of boiler water Call qualified service technician to check pH level and correct. pH should be maintained between 7.0 to 8.5. Insufficient water flow through boiler Check all valves to and from boiler. Return to proper setting. Confirm circulator size. Metal flakes found in vent outlet or vent starter tee — flueway corrosion Contaminated combustion air supply — See manual page 13. Remove any contaminating products, see manual page 13. Provide outside air for combustion. Kit available through Weil-McLain distributor. Have qualified service technician pipe-up kit. Some radiators or baseboard units do not heat or are noisy Condensation of combustion gases in boiler sections Have qualified service technician check operation of mixing system. Repair/replace if necessary. Air in system Bleed air from system through air vents in radiators or baseboard units. Low system pressure Fill to correct pressure. Check for leaks in boiler or piping. Have qualified service technician repair at once. High limit set too low Part number 550-141-850/0699 Adjust high limit to higher setting. 73 GOLD GV Water boiler series 3 — manual XIg Troubleshooting — GCM lights CHART 1 — Troubleshooting POWER light status Electrical shock hazard — Wherever you see ▲TURN OFF POWER▲, follow the instructions. Failure to follow instructions could result in severe personal injury, death or substantial property damage. Is POWER light off? No • Make sure service switch or circuit breaker is on or fuses are good. • Remove 120 VAC IN plug (Figure 34, Item 1) on control module. • Using voltmeter, check across top and bottom pins of 120 VAC IN receptacle. Yes Is POWER light... Flashing alone Flashing with another light On steady (not flashing) TSTAT CIRC light flashing Chart 2 Chart 6 LIMIT light flashing Chart 3 Chart 7 PRES SWITCH light flashing Chart 4 FLAME light flashing Chart 5 No Yes Problem is with incoming electricity. Have licensed electrician repair circuit. • Reconnect 120 VAC IN plug. • Remove 120 VAC transformer PRIMARY plug (Figure 34, Item 2) on control module. • Using voltmeter, check across top and bottom pins of PRIMARY receptacle. For insufficient heat or no heat problem, go to Chart 8 if POWER light is on steady, with no other light flashing. • Usually indicates polarity on incoming 120 VAC power line is wrong. • ▲TURN OFF POWER▲ at service switch or breaker, then reverse the HOT and NEUTRAL wires entering the boiler in the J-box. • Restore POWER at service switch or breaker. Is POWER light flashing now? No Does voltmeter indicate 120 VAC? Yes Does voltmeter indicate 120 VAC? No Yes Replace control module. Retest. • Reinstall 120 VAC transformer PRIMARY plug. • Remove 24 VAC transformer plug (Figure 34, Item 7) on control module. • Using voltmeter, check across pins of receptacle. Does voltmeter indicate 24 VAC? No Boiler should now operate normally. 74 Have system checked by a licensed electrician. If problem persists, call your local Weil-McLain sales representative. Replace transformer. Retest. Yes Replace control module. Retest. Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance CHART 2 — TSTAT CIRC & POWER lights flashing Electrical shock hazard — Wherever you see ▲TURN OFF POWER▲, follow the instructions. Failure to follow instructions could result in severe personl injury, death or substantial property damage. Is return water temperature sensor clamped securely to the return pipe in the boiler? Yes No • Attach sensor to pipe with clamp provided. • If problem persists, replace return water temperature sensor. • Retest. • Check for stray voltage on the incoming thermostat wires. does occur under any condition, check and correct the Disconnect the two external wires connected to the boiler external wiring. (This is a common problem when using 3-wire thermostat wires. zone valves.) • Connect a voltmeter across the two incoming wires. Close • Once the external thermostat circuit wiring is checked and each thermostat, zone valve and relay in the external circuit corrected if necessary, reconnect the external thermostat one at a time and check the voltmeter reading across the circuit wires to the boiler thermostat wires and allow the boiler wires. There should NEVER be a voltage reading. If a voltage to cycle. Did you find and correct a voltage across the two external thermostat circuit wires? Yes No • Boiler should now operate per the normal sequence of operation shown in Figure 22 if wiring was corrected. Is boiler internal Bypass circulator operating? No • Remove CIRCULATORS plug (Figure 34, Item 4) from plug receptacle of control module. • Place voltmeter leads across the right-side 120 VAC N and 120 VAC H pins of the CIRCULATORS receptacle. Does the voltmeter indicate 120 VAC? No Yes • Replace GCM (control module). • Test wire continuity of circulator wire harness. • Retest. No Yes Yes • Replace circulator harness. • Retest. • Reconnect circulator harness to GCM. • Attempt to get the circulator started by giving it a sharp rap on the end of the circulator motor (to release a possibly locked impeller). • If the circulator begins to operate, allow it to operate for a few minutes to see if the problem clears. • If problem persists, replace the Bypass circulator. Part number 550-141-850/0699 • Check the boiler internal return pipe where it enters the boiler sections. The TSTAT CIRC and POWER lights will flash as long as the return water temperature is less than 130 ˚F. • Wait up to 20 minutes to give the boiler and system a chance to respond. Does problem persist? Is harness ok? No • Retest. Yes • Boiler may now be operating normally. Verify against Figure 22, sequence of operation. • If boiler appears not to be heating, troubleshoot boiler per CHART 8 (no heat problems). If problem cannot be resolved, replace water temperature sensor and retest. Then replace GCM (control module) if sensor does not correct the problem. • If boiler is heating, but the temperature at the return pipe does not increase above 130 ˚F, there may be an incorrectly-piped external circulator forcing water through the boiler. Check external piping and correct. 75 GOLD GV Water boiler series 3 — manual XIg Troubleshooting — GCM lights (continued) CHART 3 — LIMIT & POWER lights flashing Electrical shock hazard — Wherever you see ▲TURN OFF POWER▲, follow the instructions. Failure to follow instructions could result in severe personl injury, death or substantial property damage. • This is a lockout condition. The return water temperature sensor has signaled a temperature higher than 240 ˚F, but the boiler limit circuit is closed (indicating that the limit • • • • control circuit did not catch the over-temperature condition). This is probably an indication of a failure of the boiler limit control and possibly the block temperature switch as well. ▲TURN OFF POWER▲ to boiler at 120 VAC service switch. Remove CONTROL CIRCUIT plug from control module receptacle (Figure 34, Item 5). Remove a wire from one of the limit control spade connectors. Connect an ohmmeter across the left and right pins on the center row of the limit circuit harness. Does the ohmmeter indicate a shorted wire harness (zero ohms)? Yes • Replace control wiring harness. • Retest. No • Reconnect CONTROL CIRCUIT plug to control module. • Remove WATER TEMP SENSOR plug from control module receptacle (Figure 34, Item 6). • Connector an ohmmeter across the plug pins to check the sensor resistance. Does the ohmmeter indicate a shorted sensor (zero ohms)? • Replace water temp sensor. • Retest. Yes No Is boiler hot? Yes • Close the external manual gas valve. • Remove one wire from the limit control space connector. • Set a thermostat to call for heat. Then turn on power to the boiler at the 120 VAC service switch. • The boiler system circulator should come on and the control module should try to cycle the boiler. • Allow the boiler circulator to run to cool off boiler and system water. • After the boiler and system water have cooled, turn off power at the 120 VAC service switch and open the external manual gas valve. 76 No • Set limit control knob to its minimum setting. Replace wire to limit control spade connector. • Set a thermostat to call for heat. • Turn on power at 120 VAC service switch. • Control module should cycle boiler on and begin heating. • The limit control should shut off the gas valve when the temperature at the boiler pressure/temperature gauge has reached no more than about 20 ˚F higher than the limit switch setting. Does limit control shut off gas correctly? Yes • Replace control module. • Retest. No • Replace limit control and block temperature switch. • Retest. Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance CHART 4 — PRES SWITCH & POWER lights flashing Electrical shock hazard — Wherever you see ▲TURN OFF POWER▲, follow the instructions. Failure to follow instructions could result in severe personal injury, death or substantial property damage. • Reset boiler control by turning off power at service switch or turning down thermostat for at least 45 seconds. • Thermostat should call for heat and appropriate zone valves open. Does blower motor operate? No Yes Does blower motor operate? No Yes Is blower wheel turning at speed of blower motor? Wait 45 seconds. No • Remove BLOWER plug (Figure 34, Item 3) from plug receptacle of control module. • Place voltmeter leads across the 120 VAC N and 120 VAC H pins of the BLOWER receptacle. Does the voltmeter indicate 120 VAC? No Yes ▲TURN OFF POWER▲ at service switch. Does blower wheel turn freely by hand? No Yes Properly position blower wheel on blower motor shaft and tighten set screw. (Or replace blower housing assembly.) Retest. Replace blower motor. (Also check blower housing assembly. Replace if necessary.) Retest. • Remove one of the red wires connected to the pressure switch. • Check continuity across the switch terminals. Does the ohmmeter indicate the switch is closed? No Yes Replace control module. Retest. ▲TURN OFF POWER▲ at service switch. • Properly position blower wheel on blower motor Wait 5 minutes. shaft and tighten set screw. (Or replace blower Is purge light flashing? housing assembly.) No Yes • Retest. Boiler should be in normal operating sequence. Observe operation until thermostat is satisfied and blower has completed its postpurge cycle. Check condensate trap. Is there condensate present? No Yes Are vent or combustion air passages blocked? No Check air pressure switch per manual Section XI. Replace if necessary. Retest. Part number 550-141-850/0699 Yes Drain condensate. Retest. Yes Clear passages and recycle boiler. Recheck boiler operation. 77 GOLD GV Water boiler series 3 — manual XIg Troubleshooting — GCM lights (continued) CHART 5 — FLAME & POWER lights flashing Electrical shock hazard — Wherever you see ▲TURN OFF POWER▲, follow the instructions. Failure to follow instructions could result in severe personal injury, death or substantial property damage. Are manual main shutoff valve and gas valve turned on? No • Open manual gas valve. • Restart boiler, following Lighting instructions for gas valve installed on boiler (Figure 25 or 26). • Check for proper operation (per Sequence of operation, Figure 22). Yes • Check gas valve harness wires and check for tight wiring connections on gas valve and control module. Repair/ replace as necessary. • Recycle boiler by thermostat or service switch (holding power off for at least 45 seconds). • Thermostat should call for heat and appropriate zone valves close. During step 5 of sequence of operation (Figure 22), is there 24 VAC across gas valve terminals? Replace control module. Retest. No Yes • Check and/or replace igniter. • Recycle boiler by thermostat or service switch. Thermostat should call for heat and appropriate zone valves close. • Wait 5 minutes. • Boiler should now operate normally. • Original flashing FLAME light caused by igniter not operating properly. • See normal sequence of operation, Figure 22. Are FLAME & POWER lights flashing? No Yes • Check and/or replace gas valve. • Recycle boiler by thermostat or service switch. Thermostat should call for heat and appropriate zone valves close. • Wait 5 minutes. Are FLAME & POWER lights flashing? No Yes • Boiler should now operate normally. • Original flashing FLAME light caused by gas valve not operating properly. • See normal sequence of operation, Figure 22. 78 Call your local Weil-McLain sales representative. Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance CHART 6 — TSTAT CIRC light flashing and POWER light on steady Electrical shock hazard — Wherever you see ▲TURN OFF POWER▲, follow the instructions. Failure to follow instructions could result in severe personl injury, death or substantial property damage. • This is not a lockout mode. The control module is signaling that the return water temperature sensor is detecting a temperature less than 40 ˚F. • While the temperature at the boiler return water temperaure sensor is less than 40 ˚F, both of the internal boiler circulators will run continuously, even if there is no call for heat (though the boiler will not fire until the thermostat calls for heat). This operation is intended to reduce chances of freezing during system down times by keeping water flowing. Is return water temperature sensor clamped securely to the return pipe in the boiler? • Attach sensor to pipe with clamp provided. No Yes • If problem persists, replace return water temperature sensor. • Retest. Are both boiler internal circulators operating? No • Remove CIRCULATORS plug (Figure 34, Item 4) from plug receptacle of control module. • Place voltmeter leads across the 120 VAC N and 120 VAC H pins of the CIRCULATORS receptacle on the side corresponding to the circulator not operating. Does the voltmeter indicate 120 VAC? No Yes • Replace GCM (control module). • Test wire continuity of circulator wire harness. • Retest. Is harness ok? No Yes • Replace circulator harness. • Retest. Yes Is there a call for heat? (Verify by removing thermostat wirings at boiler and checking continuity across external wires) No Yes • This is normal operation for water less than 40 ˚F at boiler internal return pipe. • Wait 10 minutes to allow heat from the boiler to raise the water temperature. • Condition should change after a call for heat, when the boiler will heat up the water. Does LIMIT light quit flashing (and pipes begin to heat up)? No • Reconnect circulator harness to GCM. • Boiler is not heating. • Attempt to get the circulator started by giving it a sharp rap on the end of the circulator motor (to release a possibly locked impeller). • Troubleshoot boiler using CHART 8. Yes • If the circulator begins to operate, allow it to operate for a few minutes to see if the problem clears. • If problem persists, replace the bypass circulator. • Boiler should now operate normally. • Retest. • Verify correct sequence of operation using Figure 22. Part number 550-141-850/0699 79 GOLD GV Water boiler series 3 — manual XIg Troubleshooting — GCM lights (continued) CHART 7 — LIMIT light flashing and POWER light on steady Electrical shock hazard — Wherever you see ▲TURN OFF POWER▲, follow the instructions. Failure to follow instructions could result in severe personl injury, death or substantial property damage. • This is not a lockout mode. The control module should only be signaling that the water temperature sensor is either shorted or there is an open circuit across the sensor terminals.. • This situation is usually corrected by replacing the sensor, as described below. • Remove SENSOR plug from receptacle on GCM (Figure 34, Item 6). Then re-insert. Does LIMIT light still flash? No Yes • Replace sensor and harness. Does LIMIT light still flash? No Yes • Boiler may now be operating correctly. Verify per normal sequnce of operation in Figure 22. • Replace GCM (control module). • Retest. 80 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance CHART 8 — Insufficient heat or no heat to system (POWER light on steady) Electrical shock hazard — Wherever you see ▲TURN OFF POWER▲, follow the instructions. Failure to follow instructions could result in severe personl injury, death or substantial property damage. • Has it been at least 5 minutes since setting thermostat to call for heat? If not, wait 5 minutes. Is system heating? • Is thermostat set to call for heat? Remove thermostat wires at boiler and check continuity across the two wires. If circuit isn't closed, check external thermostat (zone valve, relay, etc.) wiring. Correct problems and retry. • Reconnect external thermostat wiring at boiler. Is thermostat circuit closed (continuity across wires)? No Yes Are all red lights off? No Yes Wait 30 seconds. Are all red lights off? No • Boiler is in standby. • Set thermostat to call for heat and recheck operation. • Verify Sequence of operation, Figure 22. No Yes • Remove CIRCULATORS harness plug from CIRCULATORS plug receptacle (Figure 34, Item 4). Check with voltmeter across left-side 120 VAC N and 120 VAC H pins of receptacle. Does voltmeter show 120 VAC across pins? No Yes • Replace control module. • Retest. • Repair/replace circulator. Retest. • Repair/replace wiring. Retest. • Wait 5 minutes. Yes Is FLAME light on? No Replace control module. Retest. • Check block switch on top of boiler with continuity checker. Are block switch contacts closed? No Yes • Wait for cast iron block to cool to room temperature. • Check limit switch contacts with continuity checker. Are block switch contacts closed? No Is boiler System circulator operating? Yes Are limit switch contacts closed? Yes No Yes • If you have sufficient heat — boiler should be in normal operating sequence. (See normal sequence of operation, Figure 22.) • If you have less than sufficient heat — Is vent or combustion air piping free of blockage? No Yes • Correct conditions and recheck operation. • See Figure 22 for normal sequence of operation. Contact your Weil-McLain sales representative. • Wait for boiler water to cool to temperature 20 to 30 ˚F lower than temperature set on limit switch. Replace block switch. Retest. Replace control module. Retest. Replace limit switch. Retest. • Excessive block temperature has been reduced to safe operating level. Check for low water level or mineral deposits in sections. Correct before proceeding. • Restart boiler and check normal sequence of operation. (See normal sequence of operation, Figure 22.) Part number 550-141-850/0699 Are limit switch contacts closed? No Yes • Boiler water temperature exceeded setting on limit switch with thermostat calling for heat. Boiler is OK. (See normal sequence of operation, Figure 22.) • Also check operation of setting on limit switch (should be above 140˚F.). 81 GOLD GV Water boiler series 3 — manual XIIa Replacement parts — overview ❏ Accessory bag assembly (shipped with boiler) ❏ Section assembly (boiler sections, tie rods, base rail legs, blower support bracket, block temperature switch) ❏ Jacket assembly (jacket parts) ❏ Blower assembly (blower, motor, air inlet hose and fittings, condensate trap parts, igniter, gas valve, gas/air orifice and manifold, burner and gasket) ❏ Trim assembly (circulators, piping components, limit control, P/T gauge, relief valve, drain valve) ❏ Interior panel (jacket interior panel, transformer, GCM control module, air pressure switch) 82 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance XIIb Replacement parts — accessory bag Table 5 The parts below are shipped with the boiler in the accessory bag. Item Description number 1 Water trim bag assembly #2 Weil-McLain part number Quantity Remarks 542-200-309 1 Nipple, BK 1 x 3.00 561-326-405 561-326-515 1 1 Relief valve thru jacket Tee to tee — Series 2 Tee to cross — Series 3 4 Tee, BK 1 x 1 x ½ 561-541-216 1 To mount pressure/temp gauge 5 Water trim bag assembly #1 542-200-308 1 6 Bushing, BK C1 ½ x ¼ 560-807-366 Screw, sheet metal type A pan 562-138-550 head phil— 10 x .50 BK Phosphate 1 Tee to gauge 7 4 Jacket back panel 8 Bag, plastic 4.00 x 6.00 x .004 540-202-749 1 Contains items 6 & 7 Contains items 1, 2, 3, 4 & 5 2 Nipple, BK ¾ x 3.00 3 9 Bag, plastic 4.00 x 6.00 x .004 540-202-749 1 10 Gauge, pressure/temperature 2 ½" short shank U.S. Gauge/Ametek 199994 (unipak) or U.S. Gauge/Ametek 199996 (bulk) or ENFN. 4104-2-2-½-¼-CBN 510-218-099 1 11 Valve, relief ¾ 30 PSI Watts ¾ W330-HI 030 511-546-920 1 12 Water trim bag assembly #3 Exhaust, tube spacer 542-200-310 1 560-907-642 2 13 14 Screw, sheet metal type A pan head phil — 10 x .50 BK Phosphate 562-138-550 4 15 4 16 Washer, lock #10 external tooth type A 562-248-680 Screw, sheet metal type A pan head 562-150-248 slotted — 10 x 1.25 ZP 8 For intake/exhaust plates 17 Plastic anchors 563-210-627 8 For #10 screws 18 Bag, plastic 4.00 x 6.00 x .004 540-202-749 1 Contains items 13, 14, 15, 16 & 17 Cap to cap mounting plate 19 Intake/exhaust air, cap plastic 560-907-641 1 20 Intake/exhaust air, mounting plate 452-100-160 1 21 Intake/exhaust air, backing plate 452-100-163 1 22 Hole template 550-108-065 1 23 Vent instruction sheet (Vent/Air Intake Termination) 550-141-778 1 24 Drain bracket assembly 542-200-300 1 25 Label, Accessory bag 550-225-031 1 Insert so text is visible from outside of bag (0299) 26 Bag, plastic 16.00 x 18.00 x .006 540-202-752 1 Contains items 1, 10, 11, 12, 19, 20, 21, 22, 23, 24 & 25 Part number 550-141-850/0699 (1196) 83 GOLD GV Water boiler series 3 — manual XIIc Table 6 Replacement parts — section assembly Section assembly Item Description number 1 Weil-McLain part number Block assembly, includes: Front section, intermediate section, back section, square cut seals — 2", silicone sealant, tie rods, tie rod nuts, tie rod washers, water tubing male adapters — 1" NPT, water tubing, pump to return, blower flange gasket, igniter, igniter gasket, screws, lock washers, studs, nuts 3 322-200-280 4 322-200-281 5 322-200-282 6 322-200-283 2 Front section Also requires repair parts kit consisting of: Square cut seals — 2", silicone sealant, tie rod nuts, tie rod washers, water tubing, male adapters — 1" NPT, water tubing, pump to return, blower flange gasket, igniter, igniter gasket, screws, studs, nuts, lock washers All 312-200-150 382-200-300 3 Intermediate section Also requires repair parts kit consisting of: Square cut seals — 2", silicone sealant, tie rod nuts, tie rod washers All 312-200-110 382-200-305 4 Back section Also requires repair parts kit consisting of: Square cut seals — 2", silicone sealant, tie rod nuts, tie rod washers All 312-200-130 382-200-305 5 Tie rods 3 560-234-499 4 560-234-525 5 560-234-503 6 560-234-504 3&4 452-100-170 5&6 452-100-172 6 84 Model Base rail legs 7 Base rail brace All 452-100-080 8 Blower housing support All 452-100-111 9 Block temperature limit switch All 510-350-068 10 Inspection port cover All 560-907-629 11 Inspection port gasket All 590-317-628 12 Starter tee gasket All 590-317-629 13 Stud, ⁵⁄₁₆" - 18 x 1.25 All 560-340-581 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Figure 35 Section assembly 85041 Part number 550-141-850/0699 85 GOLD GV Water boiler series 3 — manual XIId Table 7 Item number 1 86 Replacement parts — jacket assembly Jacket assembly Description Jacket panel, top 2 Jacket panel, front 3 Jacket panel , left side 4 Jacket access panel 5 Jacket panel, right side Model Weil-McLain part number 3&4 422-200-146 5&6 422-200-150 All 422-200-140 3&4 422-200-220 5&6 422-200-222 All 422-200-230 3&4 422-200-224 5&6 422-200-226 6 Jacket panel, rear All 422-200-135 7 Top rail brace All 422-200-232 8 Top rail cross tie All 422-200-137 9 Jacket panel, interior All 422-200-228 10 Base rail assembly (see Section assembly on page 84 for details) --- -------------- 11 Screw, sheet metal type AB, serated hex washer head Phillips #10 x ³⁄₈" steel black phospate All 562-150-273 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Figure 36 Jacket assembly 85042 Part number 550-141-850/0699 87 GOLD GV Water boiler series 3 — manual XIIe Table 8 Replacement parts — Blower assembly Blower assembly Item number Description 1 Burner replacement kit, includes: Burner cone and ring assembly, blower flange gasket, igniter, igniter screws, igniter washers, igniter gasket 2 3 4 Blower flange gasket Air pressure switch (0 to 5,500 feet elevation) Blower motor replacement kit, includes: Blower motor, motor mount grommets, screws, lock nuts, 9" Allen wrench Blower housing assembly replacement kit, includes: Blower housing, observation port window, blower housing cover plate, blower motor mounting brackets, washer hold down bracket, lock nuts, motor mount grommets, blower motor, blower wheel, magnetic washer, silicone sealant, screws, blower flange gasket, igniter, igniter screws, igniter washers, igniter gasket Conversion kit, natural to propane, includes . . . . . . . . . . . . . . . . . . . . . . Propane orifice plate, label 5 6 Conversion kit, propane to natural, includes . . . . . . . . . . . . . . . . . . . . . . Propane orifice plate, label 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 88 Gas/air manifold assembly, includes: Gas/air manifold, gas tubing, washers, screws Condensate trap kit, includes: Condensate trap, hoses Gas valve tubing to gas/air manifold, red Gas valve assembly replacement kit, includes: Gas valve, gas supply manifold and bracket Gas manifold assembly, includes: Gas supply manifold, bracket Igniter replacement kit (includes gasket) Igniter gasket (included in item 12, above) Inlet air fitting Hose clamp, 3" Inlet air hose Inspection port cover Inspection port gasket Starter tee gasket Drain hose clamp, 5/8” Condensate trap hose Drain bracket Drain ell Model Weil-McLain part number 3 4 5 6 All All All 382-200-320 382-200-325 382-200-330 382-200-335 590-317-610 511-624-520 382-200-345 All 382-200-340 3 4 5 6 3 4 5 6 All 510-811-600 510-811-605 510-811-610 510-811-615 510-811-620 510-811-625 510-811-630 510-811-635 382-200-355 All 382-200-409 All All 590-317-647 382-200-410 All 591-126-800 All — All All All All All All All All All All 511-330-148 — 560-907-635 591-850-068 562-302-547 560-907-629 590-317-628 590-317-629 591-850-071 562-302-548 452-100-112 560-907-650 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Figure 37 Blower assembly Vent starter tee — not included 85043 Part number 550-141-850/0699 89 GOLD GV Water boiler series 3 — manual XIIf Table 9 Replacement parts — trim assembly Trim assembly Item Description number 90 Weil-McLain part number 1 Circulator flange, 1" NPT 563-910-026 2 Circulator gasket, Taco 110-339 3 System circulator, Taco 007F 590-317-543 511-405-113 4 Bypass circulator, Taco 007F 511-405-113 5 Wiring harness, dual circulators to control module 591-391-824 6 Nipple, NPT — 1" x close 561-326-500 7 Ell, 1" 563-115-300 8 Nipple, NPT — 1" x 4 ½" 561-326-528 9 Tee, 1" 561-541-212 10 Nipple, NPT — 1" x close 561-326-500 11 Nipple, NPT — 1" x close 561-326-500 12 561-550-000 13 Cross, 1" Bushing, 1" x ¹⁄₈" 14 Vent coin, ¹⁄₈" NPT 510-148-565 15 Nipple, NPT — 1" x 4" 561-326-527 16 Reducing tee, 1" x 1" x ½" 561-541-216 17 Bushing, ½" x ¼" 560-807-366 18 Combination pressure-temperature gauge, 2 ½" short shank 510-218-099 19 Nipple, NPT — 1" x 4" 561-326-527 20 ASME Pressure relief valve, ¾" male inlet, 30 PSIG 511-546-920 21 Nipple, NPT — ¾" x 3" 561-326-405 22 Block temperature limit switch 510-350-068 23 Limit control 510-312-244 24 Limit control well, ½" Included with limit 25 Return pipe section 560-742-938 26 Drain valve, ¾" 511-246-392 27 Inspection port cover 560-907-629 28 Starter tee gasket 590-317-629 29 Water temperature sensor and clamp 511-330-089 30 Inspection port cover gasket 590-317-628 560-807-378 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Trim assembly SYST EM Figure 38 85048 Part number 550-141-850/0699 91 GOLD GV Water boiler series 3 — manual XIIg Table 10 Replacement parts — interior panel Interior panel Item Description number 92 Weil-McLain part number 1 Interior panel with controls 542-200-302 2 Control module assembly, includes control module and screws 542-200-235 3 Transformer 511-842-370 4 Air pressure switch 511-624-520 5 Wiring harness, control module to junction box (not shown) 591-391-821 6 Wiring harness, control module to hot surface ignitor (not shown) 591-391-819 7 Wiring harness, control module to system and bypass circulators (not shown) 591-391-824 8 Wiring harness, control module to controls (not shown) 591-391-892 Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Figure 39 Interior panel 85046 Part number 550-141-850/0699 93 GOLD GV Water boiler series 3 — manual XIII Figure 40 Dimensions and ratings Dimension drawing (see dimension table on opposite page) L 85049 Item number 1 2 3 4 5 6 7 8 9 10 11 12 13 94 Description 1" NPT Supply 1" NPT Return Combination pressure-temperature gauge, 2 ½" short shank ¾" NPT Relief valve outlet Plug dome, 2" black Junction box Inlet air fitting 3" Diameter flue outlet ½" Condensate drain ½" NPT Gas supply connection (provided by others) Drip leg (provided by others) Union (provided by others) Manual main shutoff gas valve (provided by others) Part number 550-141-850/0699 • Installation • Start-Up • Parts • Maintenance Table 11 Boiler model Boiler dimensional data (see Figure 40) Supply Return Length L Gas connection size (Note 1) Crate dimensions (outside measurement, inches) Approx. shipping weight (in. NPT) (in. NPT) (inches) (in. NPT) Length Width Height (pounds) GV–3 1 1 30¾ ½ 33½ 22 36 270 GV–4 1 1 30¾ ½ 33½ 22 36 320 GV–5 1 1 37¾ ½ 33½ 22 43 355 GV–6 1 1 37¾ ½ 33½ 22 43 410 Note 1 Gas piping from meter to boiler to be sized per local utility requirements. Table 12 Boiler model number Boiler ratings AGA Input Btuh DOE Heating Net I=B=R capacity Btuh ratings Btuh (Note 1) (Note 2) DOE Vent/combustion Boiler water Seasonal air diameter content efficiency (%) (inches) (gallons) GV-3 70,000 61,000 53,000 87.5 3 3.3 GV-4 105,000 92,000 80,000 87.3 3 4.2 GV-5 140,000 122,000 106,000 87.2 3 5.1 GV-6 175,000 153,000 133,000 87.0 3 6.0 Notes: 1. Based on standard test procedures prescribed by the United States Department of Energy. Ratings also referred to as AGA/ CGA Output. 2. Net I=B=R ratings are based on net installed radiation of sufficient quantity for the requirements of the building and nothing need be added for normal piping and pickup. Ratings are based on a piping and pickup allowance of 1.15. An additional allowance should be made for unusual piping and pickup loads. Boilers are tested for 50 lbs working pressure. GV boilers are not available for millivolt systems. Part number 550-141-850/0699 95 GOLD GV W ater boiler — Series 3 Water Weil-McLain 500 Blaine Street Michigan City, IN 46360-2388 http://www.weil-mclain.com 96 Part number 550-141-850/0699
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 1999:07:28 10:01:53 Producer : Acrobat Distiller 4.0 for Windows Title : 550-141-850/0699 Author : Heating Illustrated Creator : Adobe PageMaker 6.52 Subject : GOLD GV Series 3 Boiler Manual Modify Date : 1999:07:28 10:11:37-05:00 Page Count : 96EXIF Metadata provided by EXIF.tools