Westell CSI510-04 Bidirectional Amplifier User Manual UserMan 510smr900

Westell, Inc. Bidirectional Amplifier UserMan 510smr900

Exhibit D Users Manual per 2 1033 c3

    Model 510SMR 900In-Building Amplifier Installation and Users Manual      Cellular Specialties, Inc.
      DISCLAIMER All information and statements contained herein are accurate to the best of the knowledge of Cellular Specialties, but Cellular Specialties makes no warranty with respect thereto, including without limitation any results which may be obtained from the products described herein or the infringement by such products of any proprietary rights of any persons.  Use or application of such information or statements is at the user's sole risk, without any liability on the part of Cellular Specialties, Inc.  Nothing herein shall be construed as license or of recommendation for use, which infringes upon any proprietary rights of any person.  Product material and specifications are subject to change without notice.  All sales of the product or products described herein are subject to Cellular Specialties' standard terms of sale and the specific terms of any particular sale.  The serial number may be found on the label on the rear panel of the unit.  For yourconvenience, note this number below, and retain this manual, along with proof of purchase , toserve as a permanent record of your purchase in the event of a theft, or for future reference.MODEL NUMBERNAME OF COMPANYDATE OF PURCHASE510SERIAL NUMBER FCC ID NVRCSI510-04This device complies with Parts 90 and 2 of the FCC Rules.
 MANUAL510SMR900 REV 0 960-1003-900 2TABLE OF CONTENTS    1.0  SAFETY GUIDELINES  3 2.0  PRODUCT DESCRIPTION  4   MECHANICAL OUTLINE DRAWING  5 3.0  GENERAL SPECIFICATIONS  6 4.0  INSTALLATION  7 5.0  AMPLIFIER ADJUSTMENT  9 6.0  TROUBLESHOOTING  10
 MANUAL510SMR900 REV 0 960-1003-900 3SAFETY GUIDELINES     GROUNDING This amplifier system is designed to operate from single-phase 120VAC power and should always be operated with both the neutral and ground wires properly connected.  Do not remove or otherwise alter the grounding lug on the power cord.   EXPLOSIVE ATMOSPHERES This product has an integral circuit breaker, which may cause an electrical flash if the breaker should reset.  To avoid explosion or fire, do not operate this product in the presence of flammable gases or fumes.   LIGHTNING DANGER Do not install or make adjustments to this unit during an electrical storm.   NO USER SERVICEABLE PARTS INSIDE HAZARDOUS VOLTAGES ARE PRESENT WHEN THE COVER IS REMOVED.  Opening the chassis will void your warranty.  If you suspect a malfunction with this product, call your dealer or the Cellular Specialties Support Line at (603) 626-6677.  !The general safety information in this guideline applies to both operatingand service personnel.  Specific warnings and cautions will be found inother parts of this manual where they apply, but may not appear in thissummary.  Failure to comply with these precautions or specific warningselsewhere in the manual violates safety standards of design,manufacture, and intended use of equipment.  Cellular Specialties, Inc.assumes no liability for the customer's failure to comply with theserequirements. 1.0
 MANUAL510SMR900 REV 0 960-1003-900 4PRODUCT DESCRIPTION    Cellular Specialties, Inc. developed the Model 510smr900 Bi-Directional Amplifier (BDA) for use in enclosed structures where sufficient signal from local cell sites to operate cell phones was unavailable within the building. It is necessary that sufficient signal be available on the roof of the structure. The BDA is connected to an external antenna, usually on the roof, and to one or more internal antennas placed strategically throughout the area where phone service is desired.  The external antenna is usually a directional type such as a "Yagi" however an omni-directional antenna may be used when the building is located in close proximity to one or more cell sites. Internal antennas are usually omni-directional although various other types may be used for certain installations. The BDA amplifies both the "uplink" (phone to tower) and "downlink" (tower to phone) signals thus facilitating communications to and from the local cell site. There are four amplification stages on the downlink and four on the uplink for a total of 60 dB nominal gain for each link.  Both links have manual gain control settings accessed through DIP switches on the top of the unit plus an AGC control for both the uplink and downlink.  There are LED indicators for power on, transmitter on, uplink overload and downlink overload. An automatic amplifier safety shutdown circuit is also present which will disable the transmitters for ten seconds should the uplink or downlink overloads be reached to prevent excessive intermodulation and oscillation.  2.0
 MANUAL510SMR900 REV 0 960-1003-900 5 +5VDC  GND (FCC Label) (Serial No.) 2 AMP
 MANUAL510SMR900 REV 0 960-1003-900 6 GENERAL SPECIFICATIONS  All specifications stated as typical unless otherwise noted.     Cellular Specialties, Inc. reserves the right to change these specifications at any time without notice. 3.0   Uplink (Phone to Tower)  Downlink (Tower to Phone) Frequency  896 – 901 MHz  935 – 940 MHz Pass Band Ripple  ± 2 dB  ± 2 dB Gain @ Zero Attenuation  60 dB  60 dB Gain Adjustment Range  -28dB -28dB Linear Output Power (typical)*  +27 dBm  +27 dBm Noise Figure (max)  5.5dB 5.5dB Maximum Input Power**  +10 dBm  +10 dBm VSWR  2.0:1 Max Propagation Delay  <250 nsec. Impedance  50 Ohms Connectors  ‘N’ Female Power Requirements  120 VAC @ 500mA Size  14” x 11.5” x 4.5” Weight  8.8 Lbs., 4 kg Operating Temperature  -22 to +118°F, -30 to +48°C Indicator LEDs  Power, Transmitter On, Uplink Overload, Downlink Overload Controls  Power switch with fuse, AGC switch, Uplink and Downlink attenuation switches 0 - 28dB in 4 dB steps.  NOTES *  Maximum total output power without exceeding the FCC allowable emissions of –13 dBm. **   Maximum safe input power at maximum gain with no damage.
 MANUAL510SMR900 REV 0 960-1003-900 7INSTALLATION CSI recommends that all BDA installations be coordinated through the local wireless provider.  Note: The Installer should refer to the Safety Precautions, in the following section, for proper antenna selection and installation             Important note: A high degree of isolation must be afforded to prevent any re-generative feedback in the system. Feedback of this nature causes the amplifier to emit a continuous signal of maximum amplitude and could, in some cases, interfere with normal operation of the cell site. The minimum required isolation of 70 dB can usually be obtained by mounting the outside antenna away from the edges of the roof. The use of window mounts or other non-rooftop mountings should be avoided.   !WARNING! AMPLIFIER DAMAGE WILL OCCUR IF A HANDSET IS CONNECTED DIRECTLY TO THE BDA OR THE COAX THAT LEADS TO THE BDA. 4.0
 MANUAL510SMR900 REV 0 960-1003-900 8 SAFETY PRECAUTIONS For INDOOR use, an Omni-Directional Antenna with a maximum gain of 3dBi is authorized for use with this unit. Inside antennas must be positioned to observe minimum separation of 20 cm. (~ 8 in.) from all users and bystanders. For the protection of personnel working in the vicinity of inside (downlink) antennas, the following guidelines for minimum distances between the human body and the antenna must be observed.  The installation of an INDOOR antenna must be such that, under normal conditions, all personnel cannot come within 20 cm. (~ 8.0 in.) from any inside antenna. Exceeding this minimum separation will ensure that the employee or bystander does not receive RF-exposure beyond the Maximum Permissible Exposure according to section 1.1310 Limits for General Population/Uncontrolled Exposure.   For OUTDOOR use, a Directional Antenna up to a maximum gain of 3 dBi is authorized for use with this unit. The Outside antenna must be positioned to observe minimum separation of 20 cm. (~ 8 inches) from all users and bystanders. For the protection of personnel working in the vicinity of outside (uplink) antennas, the following guidelines for minimum distances between the human body and the antenna must be observed.  The installation of an OUTDOOR antenna must be such that, under normal conditions, all personnel cannot come within 20 cm. (~ 8 inches) from the outside antenna.  Exceeding this minimum separation will ensure that the worker or bystander does not receive RF-exposure beyond the Maximum Permissible Exposure according to section 1.1310 Limits for General Population / Uncontrolled Exposure. !!
 MANUAL510SMR900 REV 0 960-1003-900 9  Example: Standard Single Internal Antenna System Design
 MANUAL510SMR900 REV 0 960-1003-900 10  AMPLIFER ADJUSTMENT In most cases the BDA will need very little adjustment. After connecting the coax and powering up the BDA, the signal levels within the previously surveyed areas should be checked for adequate RSSI levels. Measurements should be made at the perimeter of the building both inside and outside. It is important that the RSSI levels measured outside the building remain close to those measured prior to installation of the BDA.  Both the uplink and downlink overload indicators should remain off.  If either indicator is illuminated, the gain of the appropriate link should be reduced. If the gain of the amplifier needs adjustment the uplink and the downlink may be adjusted by means of the step attenuators on the top of the unit. Attenuation from 0 dB to 28 dB in steps of 4 dB may be inserted by proper selection of the 4, 8 and 16 dB attenuators. If satisfactory cell (or two-way) phone performance is not obtained when the phone is in close proximity to the interior antenna it may be necessary to decrease the gain of one or both of the links.  5.0
 MANUAL510SMR900 REV 0 960-1003-900 11 TROUBLESHOOTING  All cables should be carefully checked for “shorts” and “opens”.  The rooftop antenna, if directional, should be checked for proper alignment along the calculated compass heading. Typically, the directional antenna should be aimed at the same site that your handset uses in the area where the outside antenna is placed. If cables and alignment are O.K. it may be necessary to use a spectrum analyzer to examine the signal environment in which the BDA is operating. The existence of strong analog signals within the frequency bands can cause problems particularly on the downlink. In some cases additional filtering might be required to reject these unwanted signals. In some instances the directional outside antenna can be reoriented, horizontally to place the interfering source in an antenna pattern “null”. There also may be some cases where the interference from outside signals is so great that they can not be filtered or otherwise reduced or eliminated without expensive and possibly prohibitive measures. In these cases it may not be practical to use the BDA for providing coverage at these sites.       6.0