Westell DR-PROD8 Bidirectional Amplifier User Manual D960 1042 004 r001 CSI DR ACELA BETA8 MANUAL pmd

Westell, Inc. Bidirectional Amplifier D960 1042 004 r001 CSI DR ACELA BETA8 MANUAL pmd

Exhibit D Users Manual per 2 1033 c3

CS12-555-400User  Manual
 Cellular Specialties, Inc. grants to the purchaser a fully paid license, at no additionalcharge, to copy or otherwise reproduce all or portions of the product documentation. Suchreproduction shall be for the purchasers use only.Important Safety InformationAntennas used for the purpose of radiating signals indoors are limited to a maximum gain of 3 dBi. Theoutdoor antenna used for the purpose of communicating to the wireless infrastructure is limited to 3dBigain, or any combination of gain and loss that equates to 3dB at input. Each antenna must be positionedto observe minimum separation requirements from all users and bystanders. The following guidelinesshould be used when considering separation distances.INDOOR antennas must be placed such that, under normal conditions,  personnel cannot come within20 cm (~8.0 in.) from any inside antenna. Adhering to this minimum separation will ensure that theemployee or bystander cannot exceed RF exposures beyond the maximum permissible limit as definedby section 1.1310 i.e. limits for General Population/Uncontrolled Exposure.OUTDOOR antenna must be positioned such that, under normal conditions,  personnel cannot approachcloser than 120 cm. (~4 ft.). A non- directional antenna having a maximum gain of 3 dBi is used,precautions should be taken to prevent personnel from routinely passing closer than specified.This device complies with Part 15 of the FCC Rules.  Operation is subject to the following twoconditions: (1) This device may not cause harmful interference, and (2) This devices mustaccept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class A digitaldevices, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reason-able protection against harmful interference when the equipment is operated in a commercialenvironment.  This equipment generates, uses, and can radiate radio frequency energy and,if not installed and used in accordance with the instruction manual, may cause harmfulinterference to radio communications. Operation of this equipment in a residential areas islikely to cause harmful interference in which case the user will be required to correct theinterference at his own expense.
Table Of ContentsSection 1Hardware Configuration        System Level Block Diagram..................................................................4         Block Diagram of  the Major Components...............................................5                    Module Face Plate Configuration ...........................................................6                   Module Label Locations  ........................................................................7 Section 2Installation         Physical Installation into the Train........................................................8          Required RF and Power Cabling ....................................................9-10                      Power Up and Check Out Procedures ...............................................11Section 3Hardware Operations          Location and Offset Values for Test Points.........................................12        Indicator Lights ................................................................................12        Troubleshooting ...........................................................................12-13          Warranty and Repair Procedures ................................................14-18Section 4Software Operations                   Software Operation Overview ..............................................................41        Software Behavior Under Normal Conditions ...................................41-43Terms Used in This Manual...................................................................................44Index  ................................................................................................................45
-4-Hardware ConfigurationSection 1System Level Block DiagramThis CSI repeater system is comprised of three modules and the cable assembliesthat interconnect them.The Filter Module provides frequency selection and filtering. It also houses thesystem computer.  The Power Module provides amplification and power distribution. TheEthernet/Fan Module provides, via CAT 5E cables, a computer interface access point forthe existing PCS repeater system and this Cellular repeater.
- 5 -Hardware ConfigurationBlock Diagram of the Major ComponentsSection 1
-6 -Hardware ConfigurationModule Face Plate ConfigurationSection 1Filter ModuleOne Way                 VentRJ45              CONN POWER/              FAULT LED 8 PIN DC                 CONN 8 PIN DC                 CONN  TNC RF                 CONNPower ModuleOne Way                 Vent 2 PIN DC                 CONN POWER                 LED 8 PIN DC                 CONN 8 PIN DC                 CONN 8 PIN DC                 CONN  N TYPE                FEMALE                RF CONNEthernet/Fan Module    TNC                FEMALE                RF CONN  RJ45                CONN 8 PIN DC                 CONN  N Type RF                   CONN
- 7-Section 1Module Label LocationsHardware ConfigurationPOWER POWEROUTSIGNALINDC DLOUTULIN ANTDONORFANSMODEMDASULOUTINDLGPSSIGNALPOWERINFAULTPOWER/COMEDHFCGBAEDHFCGBA16-11VEAM 0ABEDHFCGBAABGCFHDE EDHFCGBAESN #: Model #: www.cel lular special ties.comModel #: Serial #: Item #: Item #: Serial #: Model #: Model #: Serial #: Item #: 45321 COM1DC BLOCK
- 8 -InstallationSection 2Physical Installation Into The Train1. Unpack each of the three boxes that make up the CSI repeater system for theAcela train. The first box contains the Filter Module and associated components.The second box contains the Power Module and associated components.Lastly, the third box contains the Ethernet/Fan Module and associated components.2. After unpacking, the major components should include one Filter Module, onePower Module, one Ethernet/Fan Module and two Repeater MountingBrackets.The minor components are 20 #8-32 Phillips Head Machine Screws and cabling forinterconnection of the modules, which will be detailed on the next page. If any partsare discovered to be missing contact Cellular Specialties, Inc. at 1-877-844-4274 toarrange for replacements to be sent.3. Install the Repeater Mounting Brackets, one in the rack’s bottom slot and onein the rack’s top slot using 4 #8-32 Phillips Head Machine Screws for each.4. Install the Power Module in the rack’s bottom slot as shown and secure with4 #8-32 Phillips Head Machine Screws.5. Install the Ethernet/Fan Module in the rack’s middle slot as shown and securewith 4 #8-32 Phillips Head Machine Screws.6. Install the Filter Module in the rack’s top slot as shown and secure with4 #8-32 Phillips Head Machine Screws.Ethernet/Fan ModuleMounting BraketFilter ModulePower Module#8-32 Screw  20 Places
- 9 -RF and Power CablingInstallationSection 21. With each of the three modules in place, DC and RF cables can be installed. Locate the DC cable with a 8 pin                  bayonet type connector at each end (820-2117-002) and connect one end from the POWER IN port on the Filter                  Module to the POWER OUT port of the Power Module. Twist each connector clockwise until locked.2. Locate the DC cable with an 8 pin bayonet type connector at each end (820-2156-002) and connect one end from                  the SIGNAL port on the Filter Module to the SIGNAL port of the Power Module. Twist each connector clockwise until                   locked.3. Connect the DC pigtail from the Ethernet/Fan Module to the port labeled FANS on the Power Module. Twist the                   connector clockwise until locked.4. Locate two 1’ N male to N male coax jumpers (820-2064-001). One is installed  from the DL IN port on the Filter                  Module to the DL OUT port on the Power Module. The other jumper connects between the UL OUT port on the Filter                  Module to the UL IN port on the POWER Module. Note: hand tighten only.  Do not use tools to tighten ANY N                  type connectors as damage to the jumper and/or equipment may occur.5. The next  N male to N male coax connection is installed  from the DAS port on the Filter Module to the Cell port on    the left side cross band coupler in the PCS units CBC/Fan Module. The final coax jumper is connected from the port                  labelled DONOR ANT on the Power Module to the Cell port on the right side cross band coupler in the PCS Units    CBC/Fan Module.6. Connect one end of the TNC coax jumper (820-2190-001) to the port on the Filter Module labelled GPS and the                   other end to the port labled DC BLOCK on the Ehternet/Fan Module.7. Connect the Modem antenna to the port on the Filter Module labelled MODEM.8. Connect the lead from the GPS antenna to port labled COM on the Ethernet/Fan module.9. Connect the jumper (820-2190-002) port labled 1 to the GPS port on the PCS unit.10. Connect the lead from the train’s PCS system’s cross band coupler in the CBC/Fan Module to the port on the Filter                     Module labled DAS.11. Connect the CAT 5E cables (820-2194-001) as shown in the interconnect diagram on the next page.12. The final connection is to the train’s 72VDC power supply.  Locate the 2 pin power supply cable and plug it into the                    2 pin bayonet type connector on the Power Module labelled DC IN. Twist the connector clockwise until locked.
Section 2- 10 -RF and Power Cabling Note: located on the left side of the Filter Module is a standard RJ45 connector port designed to accept CAT-5E               cable, the connector is labelled COM.   This port is used to provide a computer interface.  Refer to the diagram               below for a graphical representation of the connections described on the previous page.InstallationPOWER WERUTSIGNALINDC DLOUTULIN ANTDONORFANSMODEMDASULOUTINDLGPSSIGNALPOWERINFAULTPOWER/COMModel #: Serial  #: Item #: Item #: Serial #: Model #: Model #: Serial #: Item #: 45321 COM1DC BLOCKF1E1D1INPUT POWER DIST.820-2164-001TO GPS PORT ON PCS UNIT820-2190-002TO PCS UNITCBC/FAN MODULEDAS CELL PORTTO GPS ANTENNATO PCS UNITCBC/FAN MODULEDONOR CELL PORTETHERNET/FAN PIGTAILTO 8 PIN BAYONETDC CABLE ASSEMBLYPOWER INTERCONNECT820-2117-002SIGNAL INTERCONNECT820-2156-002TNC MALE COAX JUMPER820-2190-001CAT 5E JUMPER820-2194-001ETHERNET CAT 5ETO PCS UNITCOM PORT820-2194-001N MALE 1FTCOAX JUMPER820-2064-001
-11 -Section 2InstallationPower UpTo power up the CSI repeater simply connect the 72 VDC power cable from the train to the DC IN port on the Power Module.When powered  up, the repeater will begin in the Operational Mode, using the “Band Switching Algorithm”. The repeater will notkey until boot up is complete, a GPS location fix is obtained and the unit is within an ” Area Definition”.Powerup and System Check Out ProceduresNormal OperationAfter boot up and a GPS position fix is obtain the repeater will begin operation based on the Area Definitions, “ChannelPower Measurement and Keying Decision” and “Low Isolation Detection and Protection” algorithms.  The operational softwarewill continuously monitor the repeater’s environment and make the necessary adjustments to keep the product operatingwithin specifications and FCC Type Certification.System StatusThe Software provides real time status data reporting the state of the repeater.  This status contains:Timestamp Modem Band Type Satellite CountSystem Up Time Active Filer NoBox CountSoftware Version In-band input Searching CountSystem Serial Number Measured Output Scan RX Run StateModel Number Composite Input DeKey LimitItem Number AGC Mode Scan RX Filter IDLocation AGC Attenuation # of ChannelsModem Signal Strength GPS RunState 1 -10 Channel Freq’s & SSIModem Registration Status LatitudeModem Phone Number Longitude RF Alarms: System Alarms:Modem Current Band Filter ID Over Range Synthesizer LockModem System ID Filter Name Oscillation VoltageModem Network ID Location VSWR TemperatureModem Temperature BTA Out of Band Overdrive SoftwareLow Signal HardwareNo SignalAlarmsThe Operating Software will monitor the repeater for conditions that are out of normal operation, triggering an alarmevent.  The Operating software in conjunction with the Communications Subsystem when so configured will sendalarm messages via E-mail or SMS texting to a User Provisioned account.Each Alarm has these User Provisioned Capabilities.:· Disable the System:  The Operating software can disable the System (prohibit Keying) until the alarmcondition is cleared if provisioned· Alarm Filter Conditions:  A Filter Condition (such as X number of occurrences per hour) to the alarm toprevent false or un-useful notifications if provisioned.· Send an Alarm Message:  The Operating Software can send a notification via message E-mail or SMSthrough the Communications Subsystem if provisioned.· Alarm Clear Message:  The Operating Software can send an alarm clear message when an alarmcondition clears if provisioned.Alarm Notification MessageThe alarm messages consists of the Systems Identification Tag, a summary of the current alarms, and a shortEnglish message describing the alarm condition(s). Below is a list of the alarms that will trigger an alarm messageto be sent.:Downlink Over Range Downlink High Temperature Scan Receiver Low UncalibrationUplink Over Range Downlink Low Temperature Scan Receiver High AGC DisabledSynthesizer Error Uplink High VSWR No GPS Data Property File ErrorDAC Error Uplink Low VSWR No GPS Lock DAS FailureDC Current High Uplink Filter Load No GPS Fix Watchdog TimerDC Current Low Uplink Over Current GPS Antenna Current Modem Not RespondingDownlink High VSWR Uplink Under Current GPS Fix Filter Not Present User LoginDownlink Low VSWR Oscillation Chassis Overheat Password ChangedDownlink Filter Load Uplink High Temperature Chassis Under Temp CPU BootDownlink Over Current Uplink Low Temperature Software Abort Placed in Disabled ConditionDownlink Under Current Fan Failure Software Error In Maintenance Mode
-12-Section 3Hardware OperationsTest Point Locations and ValuesIndicator LightsThe CSI repeater, CS12-555-400, by design, has no external test points. The Power and Filter modules aresealed with no user serviceable parts inside. The Ethernet/FAN Module had no user serviceable parts, iffans are observed to fail the module can be sent back to CSI for evaluation.  Testing and configuration isdone exclusively by interfacing the repeater with a laptop or desktop computer and using the Web basedGUI or the TMI.  Both user interfaces will provide a complete status of the repeater.  In most cases if allother components of the system prove to be working properly and the repeater is not, the user will needto return the unit to CSI for inspection and repair.  See the Warranty and Repair Procedures in Section 3 ofthis manual.If the covers for the Power and or Filter modules are removed by the user the warranty will be void andthe cost of any needed repair will be the responsibility of the user.This repeater was designed with only two external indicator lights.  Both are approximately 3/4”diameter LEDs. The first is located on the Filter Module face plate, between the COM and POWER INports, and is labeled POWER/FAULT. This LED glows red as the repeater is powered up.  When the unitcompletes all of it’s bootup procedures the LED will change color and glow green to indicate thesystem is operating normally.  If the LED remains red it’s an indication of a problem and the user willneed to check the system status using the Web based GUI or the TMI.The second LED is located on the faceplate of the Power Module,  between the DC IN and POWER OUTconnector ports. This light is designed only to show that the unit has DC current and will glow greenwhen the unit is powered.TroubleshootingAll cables should be checked for shorts and opens.The rooftop antenna (Donor Antenna), should be checked for damage.The DAS antennas should be checked for damage.If cables and antennas are acceptable and the problem persists, check repeater status using the Webbased GUI or the TMI. See Alarm/Action Matrix on the next page.Should the repeater fail, or if service is lost and the cause can not be determined from the steps above, the usershould contact CSI Technical Support @ 1.877.844.4274.  CSI will remotely access the repeater and advise therespondent of next step(s).
- 13 -Hardware Operations Section 3Subsystem Alarm Name Alarm Send Shutdown DisableType E-mail Op Mode? Unit?Downlink Power Over Range Critical Yes Yes NoLow Signal Routine No No NoNo Signal Routine No No NoOut of Band Signal Routine No No NoUplink Power Over Range Critical Yes Yes NoOut of Band Signal Routine No No NoCommon Hardware Alarms Synthesizer Error Critical Yes Yes YesDac Error Critical Yes Yes YesDC Current High Severe Yes Yes NoDC Current Low Severe Yes Yes NoDownlink PA Oscillation Routine No No NoInput Power High Routine No No NoHigh VSWR Severe Yes No NoLow VSWR Severe Yes No NoFilterLoad Critical Yes Yes NoOvercurrent Severe Yes No NoUndercurrent Severe Yes No NoLow Isolation Routine No No NoHigh Temperature Severe Yes Yes NoLow Temperature Severe Yes No NoUplink PA HighVSWR Severe Yes No NoLow VSWR Severe Yes No NoFilterLoad Critical Yes Yes NoOvercurrent Severe Yes No NoUndercurrent Severe Yes No NoOscillation Routine No No NoLow Isolation Routine No No NoHigh Temperature Severe Yes Yes NoLow Temperature Severe Yes No NoFan Activation Routine No No NoFan Failure Severe Yes No NoScanning Receiver Alarms ScanRcvrLow Severe Yes Yes NoScanRcvrHigh Severe Yes Yes NoGPS Receiver Alarms No GPS Data Critical Yes Yes YesNo GPS Lock Severe Yes No NoNo GSP Fix Critical Yes Yes NoGps Antenna Current Severe Yes No NoGps Fix Filter Not Present Severe Yes Yes YesSoftware Alarm Types Overheat Severe Yes No NoUndertemp Severe Yes No NoSoftware Abort Critical Yes Yes ??Software Error Severe Yes Yes NoUncalibration Critical Yes Yes YesAgc Disabled Critical Yes Yes YesProperty File Error Critical Yes Yes NoDas Failure Critical Yes Yes NoWatchdog Timer Critical Yes Yes NoHeartbeat Informational No Yes NoCommunications Modem Not Responding Severe Yes No NoModem Not Connected Routine No No No
-14 -Hardware OperationsSection 3Warranty and Repair Procedures1  ScopeThe warranty period for this product shall be 18 months (548 calendar days)from the date of the Purchaser’s Acceptance, plus any extended mainte-nance periods as specified in the order.  During said period(s), CSI warrantsthat each repeater  will be free of defects in material and workmanship.CSI’s sole obligation and the Purchaser’s exclusive remedy for any breachof warranty is limited to adjustments, repairs, or at the Purchaser’s option,replacement of a System or parts of a System thereof at no cost to the CSI.All exchanged Systems or System parts will become the property of theCSI.  Servicing hereunder will be furnished by the CSI’s nearest servicelocation.  CSI shall perform this service at a time agreed to by the Pur-chaser.  This warranty will not apply to a particular item if:(a)  Adjustment, repair or replacement is required because of accident,neglect, misuse, failure of electric power, environmental controls, transporta-tion or causes other than ordinary use, except that such adjustment, repair,or replacement is required due to actions caused by or the responsibility ofCSI’s employees or CSI’s authorized agents;(b) The Purchaser fails to operate a System or follow operator-level mainte-nance procedures in accordance with the CSI’s recommendations;(c) Any person other than the CSI’s engineer or an authorized agent of theCSI modifies, adjusts, or repairs the product or performs any maintenanceservice other than routine operator-level maintenance without the CSI’s priorwritten consent.The warranty hereunder does not include:(a) Any furnished consumable supplies,(b) Painting or refinishing the product,(c) Electrical work external to the product,(d) Installation, maintenance or removal of alterations or attachments to theproduct except as provided by the original system design.CSI’s liability for breach of the above warranty will in no event exceed thepurchase price of the Product(s) that has been paid by the Purchaser.
- 15 -Hardware OperationsSection 32  Product Hardware Warranty (Non-Software)(a) CSI represents and warrants to the Purchaser that upon delivery of a repeater tothe Purchaser, all right, title and interest in the unit will pass to the Purchaser free ofall liens, imperfections in title, claims, charges, restrictions, or other encumbrances.The CSI represents and warrants a repeater’s Hardware (specifically excluding theProduct Software) as furnished shall be new, merchantable, free from defects inmaterial and workmanship, fit for the ordinary purpose for which the product is used,shall not infringe on any U.S. Patent, and for the period specified in this documentfrom the date a repeater is delivered and shall conform to this documents specifica-tions.  Should a unit not conform to the foregoing warranties, CSI shall repair orreplace defective or nonconforming product.(b) During the warranty period, a defective repeater shall be either repaired on-siteby the CSI or returned to the CSI for repair or replacement at no charge or cost tothe Purchaser.  The Purchaser shall bear the risk of loss or damage until a unit isplaced in the possession of the carrier.  Unless otherwise agreed to by the CSI andthe Purchaser, for a product that is returned to the CSI for repair, CSI shall completerepairs and return repaired the product, or ship a replacement product, within three(3) days of receipt of defective repeater at CSI’s designated repair location.  CSIshall bear the cost of transportation charges for shipment to CSI (FOB origin freightcollect) of the product to be repaired or replaced.  For return shipments from CSI tothe Purchaser, CSI shall bear the risk of loss or damage during transit and shallprepay and bear the cost of transportation charges for shipment of the product thathas been repaired or replaced.  If a repeater returned is not defective, CSI shallpromptly advise the Purchaser in writing of the determination and in such cases,CSI shall return product to the Purchaser at the Purchaser’s expense and risk in its“as received” condition.  If a repeater is returned and is not in warranty, CSI shallpromptly advise the Purchaser in writing of this determination and the charge torepair the product.  In such cases, CSI shall repair  the product if so instructed bythe Purchaser in writing and charge the Purchaser for labor, parts, and shipping.(c) During the warranty period, if the Purchaser’s technical personnel attempt todetermine whether or not a CSI repeater is the cause of service interruption andcannot identify and resolve the problem causing the interruption after communicatingwith CSI’s technical personnel via telephone or other suitable means, and theservice interruption still exists, then the Purchaser may request that CSI begin on-site repairs as soon as possible, but in no event later than one (1) business dayplus reasonable travel time after receiving the Purchaser’s request.  If the problem iswith CSI’s product, (software or hardware), such on-site repairs by CSI shall be atno charge to the Purchaser.Warranty and Repair Procedures
-16 -(d)  During the Warranty period, if the service interruption still exists after compliancewith (c) above, and the service interruption is caused by either CSI’s defective repeater(s)and/or CSI’s product that does not confirm to specification and the CSI has been given areasonable time frame, as determined by the Purchaser, to correct the service interrup-tion, the Purchaser may return the product to CSI and receive a credit for the totalpurchase price of the Product or a completely new repeater, at the Purchaser’s option,.(e)  Any replacement, repair, modification, installation or other service performed by  CSIshall be warranted, commencing with the date upon which repaired product is returned tothe Purchaser, for the remainder of the unexpired period of the warranty.(f)  The warranties do not extend to a repeater to the extent that such repeater has beensubjected to misuse, neglect, abuse, accident caused by the Purchaser or by a thirdparty subsequent to the delivery of the unit, and such action is the cause of the damageor malfunction.Hardware OperationsSection 3Warranty and Repair Procedures3  Product Software Warranty(a)  CSI  warrants that the Purchaser shall have quiet enjoyment of the Product Softwareand that the Product Software and the Purchaser’s use shall be free from claims of infringe-ment, misuse or misappropriation of any intellectual property right during the term of thePurchaser license to Use the Software.  As to Product Software which the CSI does nothave title, CSI warrants that has rights in the Software sufficient to permit the license of theSoftware to  and that CSI has full right, power and authority to license the Software andother rights granted hereunder to Verizon Wireless.(b)  CSI also warrants that the media containing the Software will be free from defects inmaterial and workmanship and that all related services provided by CSI shall be rendered byqualified personnel who will perform the tasks assigned consistent with good professionalpractice and the state of the art involved.(c)  CSI also warrants that there does not exists an copy protection or similar mechanismswithin the Product Software, which will, either now or in the future, interfere with the opera-tion of the Product.  Furthermore, CSI warrants unless requested in writing by the Purchaserand the Purchaser approves response, or CSI advises the Purchaser in writing that it isnecessary to perform valid duties under this attachment and authorized in writing by thePurchaser, any Product Software provided to the Purchaser by CSI for Use by the CSI or thePurchaser shall:
- 17 -Hardware OperationsSection 3Warranty and Repair Procedures· contain no hidden files;· not replicate, transmit or activate itself without control of an of an authorizedperson operating computer equipment on which it resides;· not alter, damage or erase any data or computer programs without control of anauthorized person operating computer equipment on which it resides;· contain no encrypted imbedded key, node lock, time-out or other function,whether implemented by electronic, mechanical or other means, which restricts ormay restrict Use or access to any programs or data developed under this Agree-ment, based on residency on a specific hardware configuration, frequency ofduration of Use, or other limiting criteria (“Illicit Code”).(d)  Where the Product Software is intended to be used in transaction processing or inthe public switched network, CSI represents that nothing in the Product Softwareprecludes the Purchaser form integrating a network management solution (includingtransaction processing and network monitoring) with the Product Software.(e)  For the period specified beginning with the effective date of license of the Soft-ware, CSI represents and warrants that the Product Software will perform in accor-dance with  specifications.  If within one year (365 days) subsequent to the expirationof the warranty period CSI has not repaired the Product Software to perform in accor-dance with  specification for any exception communicated in writing by the Purchaserto CSI during the warranty period, the Purchaser may order and CSI shall refund tothe Purchaser the amount paid to it for the nonconforming Product Software.(f)  CSI represents and warrants that if any portion of the Product Software is orbecomes unusable, totally or in any respect, the Supplier will correct errors, defectsand nonconformity and restore the Product Software to conforming condition withoutadditional charge to the Purchaser.
-18 -4  Continuing Availability of Service and Parts(a)  CSI shall, if requested by the Purchaser, provide the Purchaser withmaintenance service, repair service and parts for the Product and Soft-ware, for a period of seven (7) years after extended Product and Serviceagreements have been discontinued by the Purchaser.  If CSI is unable tosupply such services and/or parts or CSI is unable to obtain an alternativesource to provide such services and/or parts for the Purchaser, then theCSI shall, without obligation or charge to the Purchaser, provide thePurchaser with drawings or other documents required to either manufac-ture or buy such parts and the technical information or any other rightsnecessary for the Purchaser to manufacture or purchase such parts forthe purpose of supporting the Purchaser’s customer base.(b) The technical information shall include, by example and not by way oflimitation:· Manufacturing drawings and specifications of materials and partscomprising the replacement and repair parts and components;· Manufacturing drawings and specifications covering special toolingand operation;· A detailed list of all commercially available  Continuing Availability ofService and Partsble parts and components purchased by CSI on theopen market, disclosing the part number, name and location of theCompany and price lists for the purchase; and· One complete copy of the source code used in the preparation of anysoftware licensed or otherwise acquired by the Purchaser from CSI,provided however, that such source code shall remain the property ofCSI and shall be separately licensed to the Purchaser for use by thePurchaser to support the Product.(c)  In the event that CSI either (i) does not own the source code or (ii)does not have the rights to disclose such source code, then CSI shalldisclose its licensor or owner of said source code and shall get the rightson behalf of the Purchaser.(d) Certain parts of the Product Software is subject to a licensing agree-ment and is sublicensed to the Purchaser.  In the event of the inability toprovide updates or continuing support of the application software at areasonable cost, CSI shall assist the Purchaser in locating an alternativesource.Hardware OperationsSection 3Warranty and Repair Procedures       5  Product ReturnsPlease call 1.877.844.4274 to obtain a Return Material Authorization (RMA)number for product assessment and repair.
-19 -Software OperationsSection 4General Operation OverviewWeb based GUI SessionPrimary access to the repeater is  gained using a LAN connection and a web browser program such as Firefox byMozilla, or Internet Explorer from Microsoft.  The repeater ships by default with a DHCP static IP address 192.168.1.101. *If connecting directly to the repeater from a laptop or PC with a crossover CAT-5E cable or over a LAN the user types theIP address of the repeater into the browser address line to connect.   When connection is made the user will be promptedfor a user name and password. For the purpose of the GUI session, the default user name is webuser and the pass-word is csi1234.  This can also be changed as required. Internet access is not required to use the GUI.  (Note: If you areconnecting using a laptop, verify that your Ethernet port is powered.  Some laptops will not allow Ethernet connectionwhen on battery power. If this is the case with the laptop you are using you will need to plug it in or update the powersettings.)*DHCP is a protocol that allows computers on a network to be automatically configured appropriately for that network.Networks provide DHCP service by maintaining one or more servers that listen for special broadcasts on the network,called DHCP requests.  These requests are made by computers when they first join a particular network.  The DHCPserver replies with configuration information that the requester uses to join the network.In the case of this repeater, the unit is configured to with a static address by default. This means it will not request orissue DHCP address and is unlike the PCS verion which is configures as a DHCP Server.  This means that a computerconfigured to make a DHCP request on joining a network (most laptops are set up this way) will automatically receive aconfiguration from the PCS repeater when it is connected to it via the local network port.  This connection is made witheither a crossover cable or an Ethernet switch or hub.
- 20 -Software OperationsSection 4When login is complete the user is brought to the system status page. The links on the page are activated by clicking onthem.        System Status:General Operation Overview
- 21 -Software OperationsSection 4If the user selects Local Network from the System Status page, the following screen is displayed and from here networkconfiguration can be modified as required. The default is set to DHCP Server. It is recommended you check with your IT depart-ment for explanation of the options and approval before you connect this repeater to your network or change the options.Local Network:General Operation Overview
- 22 -Software OperationsSection 4From here the user may return to the System Status screen or click on the other options. If the user would like to modify RFconfiguration click on the words RF Configuration in the brown navigation box and the screen below is displayed.RF Configuration:To change gain settings the user will select the Uplink only or Uplink and Downlink radio buttons. The user then inputs thegain value desired. Gain values from 53.5 dB to 85.0 dB may be selected. The repeater will not allow the user to setvalues outside this range. By pressing the Change Settings button the gain change is implemented.  When a new filter setis required, it may be selected by clicking Program a Filter in the navigation box.General Operation Overview
- 23 -Software OperationsSection 4The user may select the desired filter by pressing the band/sub-band and modulation selection buttons. Undesired bands/sub-bands if lit will require the user to manually “deselect” them before programming.   Pressing the Program button will completethe selection and load the desired filter. The time required to complete this process will take just a few moments.  Note: If thefilter desired is not currently in the unit, additional filters along with instructions on how to load them are available by contact-ing CSI.Program a Filter:General Operation Overview
- 24 -Software OperationsSection 4Highlight the carrier on whose network the repeater and modem will be configured and click the Change Settings button. Note:the system will require restart for the change to take effect.Remote Network:General Operation Overview
-25 -Software OperationsSection 4To change SNMP settings click SNMP Configuration in the navigation box, the screen below will be displayed. If the user is notwell versed in Simple Network Management Protocol he or she should check with their IT professional for proper settingrequirements.SNMP Configuration:General Operation Overview
- 26 -Software OperationsSection 4By clicking System Health the current state of the repeater can be reviewed.***The user may clear alarms and the Event Log by clicking the Clear Log button.System Health:***General Operation Overview
-27 -Software OperationsSection 4Should a software install or upgrade be needed it can be done from the Install & Upload screen shown below. As with the otherscreens it can be reached by clicking the words in the navigation box.Install & Upload:General Operation Overview
-28 -Software OperationsSection 4If a reboot of the repeater becomes necessary click on the Reboot option in the navigation box and the Reboot page isdisplayed.Reboot:General Operation Overview
- 29 -Software OperationsSection 4In order to review and configure the system’s alarms click on the Alarm Configuration line in the navigation box and pageshown below is displayed.Alarm Configuration:General Operation Overview
- 30 -Software OperationsSection 4In order to review and update the system’s log configuration, click on the Log Configuration line in the navigation box and pageshown below is displayed.Log Configuration:General Operation Overview
- 31 -Software OperationsSection 4Text Menu Interface:A Text Menu Interface (TMI) is provided as an alternate means of access  and control of the repeater. To use the TMI, also known asthe console interface, connect a CAT -5E cable to the RJ45 connector port labeled COM and a computer making use of a standardterminal emulation program.Many terminal emulation programs will work if properly configured.  In the following description, “TeraTerm” is used to establish theTMI session. This program is readily available via the Internet and is free from Ayera Technologies at:http://www.ayera.com/teraterm/TeraTerm Pro Web works on Windows 95/98, 2000, XP. Here is the latest TeraTerm Pro Web release:Version 3.1.3, October 8, 2002. ttpro313.zipWhen the program is started, the following screen is displayed.In the box labeled Host type the repeaters IP address and click OK.  The user will then be prompted for a user name andpassword. The default user name is “user” and the password “csi1234”.   After entering the password and pressing returnthe  TMI main menu will appear.General Operation Overview
- 32 -Software Operations Section 4General Operation OverviewUpon logging the user is presented with a summary of the initialization status. The data represents a top level list of the majorcomponents that must be operating properly in order to have a function system. The display will “block” until a particular componentis finished being initialized.Link Initialization CompleteOnce the initialization sequence is complete, the user is presented a top level menu used to access all of the systems operatingparameters. The top level menu is organized into three main sections, settable parameters, status parameters, and systemfunctions.The “Set Parameters” menu is password protected (user definable) in order to prevent erroneous configurations being made bynon-qualified users. The user will be prompted to enter the correct login and password on a per-session basis. Once the user hasentered the correct values, subsequent access is not inhibited.Enter The defalt Username is: csi The defalt Password is: csi1234
- 33 -Software Operations Section 4General Operation Overview 1. The “Link Configuration” menu is a collection of menuoptions that control the RF operating characteristics of thesystem.2. The “Alarm Configuration” menu provides options thatcontrol the alarm operating characteristics of the repeater.3. The “Networking Configuration” menu contains fourconfiguration menus. The “Local Network Configuration”provides access to the network connection that is made tothe system via the Ethernet port located on the front panel ofthe unit. The “Remote Network Configuration” is used toconfigure the wireless modem(s). The “Network ProtocolConfiguration” allows access protocols to be toggled on oroff. The “SNMP Configuration” option is not used or supportedin this version of product.4. “Log File Configuration” menu. The system is capableof storing its log files persistently on a periodic basis so thatpost mortem analysis can take place. The log files will beplaced in the “/log” directory on the compact flash. Theservice personnel can then use off the shelf applications toextract the information to their laptop for review. This menuallows the user to define aspect of the log file such asrotation period, size and number of logs retained.5. The “GPS Configuration” menu controls the operationalstate of the GPS receiver. The system is designed to runwith a GPS emulator connected to COM3 (internal) for use sa test/debug mode. Additional menu items can be used toassist in the diagnosis of GPS related issues.6. “Scan Receiver Confiuration” menu. The scanreceiver hardware is used to monitor the power levels of aset of frequencies for a given filter set. If the scannedpower level is above the maximum threshold value, the taskwill de-key the unit until such a condition no longer exists.
- 34 -Software Operations Section 4General Operation Overview1. The “Adjust Gain” option allows the user tocontrol the total gain of the system. Valid gainsettings range from 55 dB to 85 dB. If the userselects to configure the downlink gain, the uplinkgain will automatically be set to the same value. Inorder to override this condition, the user will haveto select the uplink option and adjust the gain to thedesired value.3.  “Filter Programming” allows the user toselect and program one of the loaded filters onthe system. Please note that as with option 2, theGPS task needs to be disabled otherwise thefilter selection will be overridden by the currentlocation of the system.2.“Select Active filter” can be used to togglebetween the filters loaded for test Purposes. Pleasenote that in order for this to work properly, the GPStask needs to be disabled otherwise the filterselection will be overridden by the current locationof the system.4. The “PA Output Control” menu selectionallows the user to control the state of the poweramplifier, ON or OFF. The setting overrides allother PA control tasks and is persistent acrossreboots. Care must be taken to insure the user isaware of the state of this setting so as toeliminate false keyed/de-keyed states.5. “PA Oscillation Control” enables the user totoggle the oscillation control feature off and on.When enabled this feature detects oscillations andadds attenuation until the oscillations aresuppressed.
- 35 -Software Operations Section 4General Operation Overview1. “Alarm Masking” provides the user an ability tomask or unmask individual alarms based on the knownoperating characteristics of the environment that theunit is place in. Certain alarms will occur that do notdirectly affect the proper operation of the system andcan therefore be masked. All alarms are still registeredwith the system regardless of the alarm state, usernotification only takes placed on unmasked alarms.2. The “Alarm Notification” option provides theuser the ability to configure the system to externallynotify service personnel of alarm events.3. The “Watchdog Timer Configuration”selection configures a hardware based watchdogtimer. Once enable, the software will periodicallywrite to the watchdog timer thus preventing anunscheduled reboot. Certain alarms can beconfigured to inhibit this periodic write which in turnwill reboot the system when they occur.
- 36 -Software Operations Section 41. The “Local Networking Configuration” menu allowsthe user to configure the Ethernet port to operate in one ofthree modes once enabled. If the unit is configured to have astatic IP address, then the user must know what thecharacteristics of the network are that the unit will beconnected to. In DHCP client mode, the unit will broadcast arequest for an IP address from a properly configured DHCPserver on the network. In DHCP server mode the unit willassign itself an IP address of 192.168.1.100 and it will alsolisten for DHCP IP address requests. If the user connects adevice (laptop) directly to the Ethernet port (cablingrequirements may differ) the unit will issue an IP address of192.168.1.90. The unit is currently capable of issuing oneclient address.  This is done to limit cataclysmic eventsshould the unit be connected to a network that already has aDHCP server.2. The menu for “Remote Networking Configuration”provides the user with a method to configure the modemconnected to the internal USB port of the SBC. This version ofsoftware is preconfigured to enable the default modem typeinstalled in the unit and no user selection is necessary.4. The “SNMP Configuration” menu is not supported forthis revision of the product.3. The “Network Protocol Configuration” menu is used totoggle off and on each of the available protocols.
- 37 -Software Operations Section 4The system is capable of storing its log files persistently ona periodic basis so that post mortem analysis can takeplace. The log files will be placed in the “/log” directory onthe compact flash. The service personnel can then use offthe shelf applications to extract the information to theirlaptop for review. This set of menus allows the user todefine aspects of the log files such as rotation period, sizeand number of logs retained.  With each selection theminimum and maximum allowable value as well as thecurrent value is displayed.
- 38 -Software Operations Section 4The GPS sub-system is an integral part of the control ofthe DSP based system. During normal operating mode,the GPS receiver controls the selection of filters and thekey state of the unit. The unit must first receive a validGPS string from the satellites before the unit will performproperly. The following menu allows the user to examineand configure the GPS operating parameters of the unit.The GPS mode menu controls the operational state of theGPS receiver. The system is designed to run with a GPSemulator connected to COM3 (internal) for use s a test/debug mode. Additional menu items can be used to assistin the diagnosis of GPS related issues.
- 39 -Software Operations Section 4The scan receiver hardware is used to monitor thepower levels of a set of frequencies for a given filterset. If the scanned power level is above the maximumthreshold value, the task will de-key the unit until sucha condition no longer exists. This set of menus allowsthe user to define behavior of the scan receiver.  Witheach selection the minimum and maximum allowablevalue as well as the current value is displayed.
- 40 -Software Operations Section 4The “Get Parameters” menu is available to all users inorder to view system status information and diagnosealarm information.1. The “Link Status” option displays the current stateof the system parameters. Information on this page isused to diagnose the health of the system.2. The “System Events” option displays the current listof system alarms. Alarm statistics are maintained in the“Show Counts” option.3. The “System Information” option displays thecurrent state of the non-RF parameters.4. The “Link Status Loop” option displays thecurrent state of the system on a periodic basis in theform of a string that can be parsed.            Enter loop delay            Display Mode (0 = normal, 1 = BTA changes  )
- 41 -Software Operations Section 4The “System Commands” menu is available to all users, however selections 1, 2, 3, and 6 are notsupported in this version of the product. It should be noted when selecting option 4 the system willimmediately reboot and the current TMI interface will be disconnected. When option 5 is selected thesystem will shut down and remain powered off until the power is toggled back on.
- 42 -Software Operations Section 4Software Behavior Under Normal ConditionsThe repeater’s operating software has two modes, an Operational mode and a Maintenance mode.  These aredescribed below.Operational Mode:Upon power up, the System will begin operation in the Operational Mode.  Using a “Band Switching Algorithm” the repeaterwill not key until a GPS position fix is obtained and the unit is within an Area Definition.Once GPS position fix is obtain the repeater will begin operation based on the Area Definitions “Channel PowerMeasurement and Keying Decision” and “Low Isolation Detection and Protection” algorithms.  The operational softwarewill continuously monitor the system’s environment and make the necessary adjustments to keep the product operatingwith specifications and within the normal operating range of the Product and FCC Type Certification.System StatusThe Operating Software provides real time status data that reports the state of the repeater.  This status contains:Timestamp Modem Band Type Satellite CountSystem Up Time Active Filer NoBox CountSoftware Version In-band input Searching  CountSystem Serial Number Measured Output Scan RX Run StateModel Number Composite Input DeKey LimitItem Number AGC Mode Scan RX Filter IDLocation AGC Attenuation # of ChannelsModem Signal Strength GPS RunState 1 -10 Channel Freq’s & SSIModem Registration Status LatitudeModem Phone Number Longitude RF Alarms: System Alarms:Modem Current Band Filter ID Over Range Synthesizer LockModem System ID Filter Name Oscillation VoltageModem Network ID Location VSWR TemperatureModem Temperature BTA Out of Band Overdrive SoftwareLow Signal HardwareNo SignalCurrently System events are stored to a Log File. In future releases, with the exception of the System Serial Numberand System Identifier, The Real Time Status of the Product will be saved to nonvolatile memory for retrieval. Thenonvolatile memory will be able to store 48 hours of Status data, with up to 6 complete status records per minute. Theinterval that the status records are saved will be user defined.The Operating Software will also record to nonvolatile memory and make available to a user in the Maintenance Mode:- A count and time stamp each time the processor is booted.- A count and time stamp of each time the operating software is placed into the Maintenance Mode, and the User IDof the operator that performed the action.- A count and time stamp each time the Watchdog Timer is activated, and the associated debugging informationavailable at the time of activation of the Watchdog Timer.- The count and time stamp of any activation of the “Low Isolation Detection and Protection Algorithm” as defined inattachment C of this document. AlarmsThe Operating Software has the ability to monitor a System for conditions that are out of normal operation, triggeringan alarm event.  The Operating software in conjunction with the Communications Subsystem is capable of sendingalarm messages via E-mail using standard SMTP and POP3 protocols to a User Provisioned e-mail account.Each Alarm defined has these User Provisioned Capabilities.:-Disable the System:  The Operating software can disable the System (prohibit Keying) until the alarmcondition is cleared.-Alarm Filter Conditions:  A Filter Condition (such as X number of occurrences per hour) to the alarm toprevent false or un-useful notifications if provisioned.-Send an Alarm Message:  The Operating Software can send a notification via message E-mail through theCommunications Subsystem if provisioned.-Alarm Clear Message:  The Operating Software can send an alarm clear message when an alarmcondition clears if provisioned.
- 43 -Software Operations Section 4Software Behavior Under Normal ConditionsMaintenance Mode:The repeater has, in addition to it’s normal “Operational Mode” a “Maintenance Mode”.  After system boot up this mode canbe accessed in the TMI only by typing the user name and password of service.This mode of operation provides all the same menus and features as shown in the software overview onprevious pages except that upon entering the Maintenance Mode, the product will de-key and await instructionsfrom a connected user.  During the Maintenance Mode of operation the Operating Software supports:- Manual operation of the Key/De-Key function.- Manual operation of the Area Definition Switching function.- Manual Setting of the gain setting in both the Uplink and Downlink Directions- Retrieval of all current User Provisioned Settings from the Product- Retrieval of the Current Version of software in the Product- Setting of all User Provisioned Settings- Retrieval of logged Status data- Retrieval of boot counts, Maintenance Mode entry counts, Watch Dog timer events with debugging data, andLow Isolation Detection and Protection events.- The Ability to Disable and Enable the System.- A Method to automatically place the System back into operation upon the discontinuance of the Maintenancesession.- A Method to automatically place the stem back into operation after a User Provisioned time limit of inactivity inthe Maintenance Mode.- Ability to load Operating Software into the repeater’s processor.- Ability to perform a “soft” reset of the processor.
- 44 -Terms used in this manualAGC= Automatic Gain ControlCBC= Cross Band CouplerCSI= Cellular Specialties, Inc.DAS= Distributed Antenna SystemDC = Direct CurrentDHCP= Dynamic Host Configuration ProtocolDL = Down LinkFCC = Federal Communications CommissionFPGA= Field Programmable Gate ArrayGPS = Global Positioning SystemGUI = Graphical User InterfaceIP = Internet ProtocolIT = Information TechnologiesLAN = Local Area NetworkLED= Light Emitting DiodeLNA = Low Noise AmplifierPCS = Personal Communications ServiceRF= Radio FrequencySBC= Single board ComputerSNMP= Simple Network Management ProtocolTMI= Text Menu InterfaceUL = Up LinkUSB = Universal Serial BusVSWR = Voltage Standing Wave Ratio
- 45 -IndexSymbols1, Section  4AAGC  8, 9, 44Alarm Configuration  29Alarm Notification Message  11Alarms  11BBand Switching Algorithm  11Block Diagram of the MajorComponents  5CCircuit Operational Description20Continuing Availability of Serviceand Parts  18CPU  44CSI  44DDAS  44DC IN  11default user name  19DHCP  44EERP  44Event Log  26FFAULT LED  6Filter Module  4FPGA  44GGeneral Operation Overview  19GPS  11HHardware Configuration  4, 6Hardware Operations  12IImportant Safety Information  2Indicator Lights  12Install & Upload  27Install Software  27Installation  8HHardware Configuration  4, 6Hardware Operations  12IIndicator Lights  12Install & Upload  27Install Software  27Installation  8IP address  19LLAN connection  19LED  48Local Network  21Log Configuration  30MMaintenance Mode  47Module Face Plate Configuration  6Module Label Locations  7NNormal Operation  11OOperational Mode  46Ppassword  19PCS repeater  4Physical Installation Into The Train  8POWER IN  9Power Module  4POWER OUT  9Power Up  11, 12Powerup and System Check OutProcedures  11Primary access  19Product Hardware Warranty  15Product Software Warranty  16Program a Filter  22RReboot  28Remote Network  24RF  48RF Alarms  46RF and Power Cabling  9, 10RF Configuration  22SSBC  48Section 1  4Section 2  8Section 3  11Section 4  19SNMP  48SNMP Configuration  25Software Behavior Under NormalConditions  46Software Operations  19System Alarms  46System Health  26System Level Block Diagram  4System Status  11, 20, 21system status page  20TTeraTerm  31Terms used in this manual  48Text Menu Interface  31UUSB  48VVent  6WWarranty and Repair Procedures14warranty period  14Web based GUI Session  19
D960-1042-004  rev 001