Whirlpool ES40R123 45D User Manual WATER HEATER Manuals And Guides 1203723L
User Manual: Whirlpool ES40R123-45D ES40R123-45D WHIRLPOOL WATER HEATER - Manuals and Guides View the owners manual for your WHIRLPOOL WATER HEATER #ES40R12345D. Home:Plumbing Parts:Whirlpool Parts:Whirlpool WATER HEATER Manual
Open the PDF directly: View PDF .
Page Count: 24
Download | |
Open PDF In Browser | View PDF |
® ol WATER HEATERS Installation Instructions and Use & Care Guide To obstain technical, warranty, or service assistance during or after the installation of this water heater, visit our website at: http://www.whirlpoolwaterheatersupport.com or call tool free 1-877-817-6750 When calling for assistance, 1. Model 2.7 Digit Product 3. Serial Number ................................................................... .................................................................. Water System ................................................................... 5 Electrical Requirements ................................................................. Installation Checklist ...................................................................... 7 9 Operating Your Water Heater ............................................................. Water Heater Start-Up ................................................................... Regulation ...................................................... Energy Smart _ Module/Operational Modes ................................... Electronic Thermostat .................................................................... Smart Grid Technology .................................................................. Operational Conditions ................................................................... Maintenance of Your Water Heater .................................................... of Purchase 10-12 10 10 11 12 13 14 15-23 Code (ESM) .................................................................. 17-18 Diagnostic Code (ET) .................................................................... 19-20 Trouble Shooting Chart ..................................................................... Repair Parts illustration ................................................................... 21 22 Thermostat 23 Diagram 5. Place ready: 3 4 Diagnostic Wiring of Installation 2 3-9 Unpacking Instructions Location Requirements Water Temperature information 4. Date PAGE Water Heater Safety ............................................................................ Installing Your Electric Water Heater ................................................... Piping have the following Number Table Of Contents PRINTED IN THE U.S.A 0411 please Number ............................................................ LOW LEAD COMPLIANT PART NO. 318686-000 WATER HEATER SAFETY Your safety and the safety or others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This symbol alerts you to potential hazards that can kill or hurt you and others. All willsymbol. follow the safety alert symbol and either the word "DANGER" or Thissafety is themessages safety alert "WARNING". These words mean: DANGER: indicates an imminently hazardous situation which, if not avoided, will result in death or injury. WARNING: indicates a potentially hazardous situation which, if not avoided, could result in death or injury. All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. Important Safety Instructions IMPORTANT: Hydrogen gas is produced in a hot water system served by this heater that has not been used for a long period of time (2 weeks or more). Hydrogen is extremely flammable. To reduce the risk of injury under these conditions, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system. When hydrogen is present, there will probably be an unusal sound such as air escaping through the pipe as the water begins to flow. There should be no smoking or open flame near the faucet at the time it is open. The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and requires businesses to warn of potential exposure to such substances. • WARNING: reproductive This product contains a chemical harm. • This appliance can cause low-level exposure known to the State of California to some of the substances to cause cancer, birth defects, or other listed in the Act. INSTALLING YOUR WATER HEATER Consumer Information This water heater should be installed in accordance with the local code authority having jurisdiction, the power company or electric utility, and this installation manual. In the absence of local code requirements, follow the regulations set forth in the latest edition of the National Electric Code, NFPA70. This is available from the following: Insulation Blankets The use of an insulation blanket on this water heater is not needed nor recommended. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. Your water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements, making an insulation blanket unnecessary. National Fire Protection Agency 1 Batterymarch Park Quincy, MA 02269 American National Standards Institute 1430 Broadway New York, NY 10018 Unpacking the Water Heater Check your phone listings for the local authorities having jurisdiction over your installation. Excessive Weight Hazard Use two or more people to move and install water heater. Consumer Responsibilities This manual has been prepared to acquaint you with the installation, operation, and maintenance of your electric water heater and provide important safety information in these areas. We urge you to read all of the instructions thoroughly before attempting the installation or operation of this water heater. This manual should be kept for future reference. Failure to do can result in back or other injury. IMPORTANT: Do not remove any permanent instructions, labels, or the data label from outside of the water heater or on the inside of panels. • Remove exterior packaging and place installation components aside. The manufacturer of this water heater will not be liable for any damages caused by failure to comply with the installation and operating instructions outlined in this manual. • Do not remove the envelope bag containing the water heater literature from the side of the water heater. If you lack the necessary skills required to properly install this water heater or you have difficulty following the directions, you should not proceed but have a qualified person perform the installation of this water heater. • Inspect all parts for damage prior to installation and start-up. • Completely read and understand all instructions before attempting to assemble and install this product. Replace this manual inside the envelope bag when installation is complete. Examples of a qualified personnel include: licensed plumbers, authorized electric company personnel, and authorized service person. Massachusetts code requires this water heater to be installed in accordance with Massachusetts Plumbing and Fuel Code 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00. A data plate identifying your water heater can be found adjacent to the energy smart module. When referring to your water heater always have the information listed on the data plate readily available, to include the model and serial number. Retain your original receipt as proof of purchase. • • After installation, dispose of packaging material in the proper manner. Location Requirements Site location Select a location near the center of the water piping system. It must be installed indoors and in a vertical position on a level surface, in an area where water leakage will not cause consequential damage. NOTE: Local codes and requirements in your area may require the water heater to be installed such that the bottom element is elevated from the floor at least 18 inches. The water heater should be located in an area not subject to freezing temperatures. Water heaters located in unconditioned spaces (i.e., attics, garages, basements, etc.) may require the water piping and drain piping to be insulated to protect against freezing. The drain and controls must be easily accessible for operation and service. NOTE: The water heater shall be located so it is not subject to physical damage by moving vehicles or area flooding. Figure 2 Residential Installation Garage Keep combustibles such as boxes, magazines, clothes, etc., away from the water heater area. ! I Do not use this water heater in conjunction with a spa or hot tub. Vehicle IMPORTANT: The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the water heater or to lower floors of the structure. Due to the normal corrosive action of the water, the tank will eventually leak after an extended period of time. Also, any external plumbing leak, including those from improper installation, may cause early failure of the water tank due to corrosion if not repaired. If the homeowner is uncomfortable with making the repair, a qualified person should be contacted. A suitable metal drain pan should be installed under the water heater as shown below. This metal drain pan is to protect the property from damage which may occur from normal condensate formation on the tank or leaks in the tank and pipe connections. The metal drain pan must limit the water level to a maximum depth of 2-1/2 inches and be two inches wider than the heater and piped to an adequate drain. Locate the water heater near a suitable indoor drain. Outdoor drains are subject to freezing temperatures which can obstruct the drain line. The piping should be at least 3/4"1D and pitched for proper drainage. Under seller water follow no circumstance will the manufacturer or of this water heater be held liable for any damage that is caused by your failure to these instructions. 2 1/2" Max t Pipeto adequate drain Atleast2"inchesgreaterthan the diameter ofthewater heater. Figure 1 Stop Drain Metal Drain Pan State of California NOTE: The water heater must be braced, anchored, or strapped to avoid moving during an earthquake. Contact local utilities for code requirements in your area or call 1-877-817-6750 and request instructions. Water System Piping Piping Installation Piping, fittings, and valves should be installedaccording to the installation drawing (Figure 3). If the indoor installation area is subject to freezing temperatures, the water piping must be protected by insulation. Water supply pressure should be around 50 to 60 psi and should not exceed 80 psi. If this occurs, a pressure reducing valve should be installed in the cold water inlet line. This should be placed on the supply to the entire house in order to maintain equal hot and cold water pressures. Figure 3 Water Piping Installation In a Closed System use a _.f Thermal Expansion Pressure Reducing HotWater U Outlet _ umc _ _ ValveWith + Cold Water _ 1. Min. 3. Some local codes may require, and the manufacturer of this water heater recommends, installing a mixing valve in the domestic hot water line as shown in Figure 4. These valves reduce the point-of-use temperature of the hot water by mixing cold and hot water and are readily available. Contact a licensed plumber or the local plumbing authority. 4. 5. , , If installing the water heater in a closed water system, install a relief valve or expansion tank in the cold water line as specified under "Closed System/Thermal Expansion". Install a shut-off valve in the cold water inlet line. It should be located close to the water heater and be easily accessible. Know the location of this valve and how to shut off the water to the heater. Install a discharge line from the temperature and pressure relief valve in the opening marked "T & P RELIEF VALVE". Install as specified under "Temperature and Pressure Relief Valve". After piping has been properly connected to the water heater, open the nearest hot water faucet. Then open the cold water shut off valve and allow the tank to completely fill with water. To purge the lines of any excess air and sediment, keep the hot water faucet open for 3 minutes after a constant flow of water is obtained. Close the faucet and check all connections for leaks. Water bupply Cold Water t_ Fixtures _ 1" The Installation of dielectric unions in both the hot and cold water supply lines is recommended for ease of removing the water heater for service or replacement. II InletValve T e2 perea Ruerlee__/da,v e Discharge 2. 7 Supply to I[]1 IMPORTANT:Always use a good grade of joint compound and be certain that all fittings are drawn up tight. IMPORTANT:Some models may contain energy saving heat traps to prevent the circulation of hot water within the pipes. Do not remove these inserts. Bypass _ " II . _:"IT"- IMPORTANT: Heat cannot be applied to the water fittings on the heater as they may contain nonmetallic parts. If solder connections are used, solder the pipe to the adapter before attaching the adapter to the hot and cold water fittings. Install the water piping and fitting as shown in Figure 3. Connect the cold water supply (3/4" NPT) to the fitting marked "Cold". Connect the hot water supply (3/4" NPT) to the fitting marked "Hot". Tank. I LI_ I_ I 41-- _) [ line 6" maximum above drain Drainline %/ _liP-. _::_ Metal Drain Pan ,_ 2-1/2" depth I _4_,IrDum ,_'_ t_//Z_/,_2_4k..._ _ iM:t_aSla_haUSue_::relief in cold water line per Drain section 19 MGL 142. max. Mixing 4Valve Figure Top Water Connections Mixed Water To Fixtures t Cold Water _ Unmixed Follow The Mixing Valve Manufacturer's Instructions Mixing Valve (Set To 120 o F) Inlet Please note the following: DO NOT install this water heater with iron piping. The system should be installed only with piping that is suitable for potable (drinkable) water such as copper, CPVC, or polyethylene (PEX). DO NOT use PVC water piping. Temperature and Pressure Relief Valve Explosion DO NOT use any pumps, valves, or fittings that are not compatible with potable water. Hazard • Temperature-pressure relief valve must comply with ANSI Z21.22-CSA 4.4 and ASME code. DO NOT use valves that may cause excessive restriction to water flow. Use full-flow ball or gate valves only. DO NOT use tin-lead solder in potable water lines. Use 95/5 tin antimony or other equivalent material. • Properly sized temperaturepressure relief valve must be installed in opening provided. DO NOT tamper with the energy smart module, electronic thermostat, temperature sensors, heating elements, electrical connections, or temperature and pressure relief valve. Tampering voids all warranties. Only qualified person should service these components. • Can result in overheating and excessive tank pressure. • Can cause serious injury or death. DO NOT use with piping that has been treated with chromate's, boiler seal, or other chemicals. DO NOT add any chemicals to the system piping which will contaminate the potable water supply. Figure 5 Temperature Relief Valve and Pressure Installation Optional F Closed System/Thermal models Expansion /_ Expansion Tank Capacity Needed 40psi 50psi 60psi 70psi 80psi 40 2 2 2 2 5 50 2 2 5 5 5 66 5 5 5 5 5 Line 3/4inch Do not cap min.or plug. Drain 6inch maximum Pan \ ' Drain "__) For protection against excessive pressures and temperatures, a temperature and pressure relief valve must be installed in the opening marked "T&P RELIEF VALVE" (See Figure 5). This valve must be design certified by a nationally recognized testing laboratory that maintains periodic inspection of the production of listed equipment or materials as meeting the requirements for Relief Valves for Hot Water Supply Systems, ANSI Z21.22. The function of the temperature and pressure relief valve is to discharge water in large quantities in the event of excessive temperature or pressure developing in the water heater. The valve's relief pressure must not exceed the working pressure of the water heater as stated on the rating plate. Expansion Tank Sizing Chart 30 2 2 2 2 2 Temperature and Pressure Relief Valve Discharge A properly-sized thermal expansion tank should be installed on all closed systems to control the harmful effects of thermal expansion. Contact a plumbing service agency or your retail supplier regarding the installation of a thermal expansion tank. Water Heater Capacity some Ii, Typically, a closed system includes a pressure reducing valve (PRV) on the cold water inlet (supply line). As water is heated, it expands (thermal expansion). In a closed system, the volume of water will grow. As the volume of water grows, there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakage). This type of failure is not covered under the limited warranty. Thermal expansion can also cause intermittent temperaturepressure relief valve operation: water discharged from the valve due to excessive pressure build up. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This condition is not covered under the limited warranty. Inlet Water Pressure location only (Gallons) 82 5 5 5 5 5 IMPORTANT: Only a new temperature and pressure relief valve should be used with your water heater. Do not use an old or existing valve as it may be damaged or not adequate for the working pressure of the new water heater. Do not place any valve between the relief valve and the tank. A thermal expansion tank can help prevent damage to the water heater and other appliances (i.e.: washing machine, ice maker, dishwasher, etc.). IMPORTANT: Do not plug or remove the temperature and pressure relief valve (T&P valve). 6 The Temperature & Pressure Relief Valve: • Must be connected to an adequate discharge line. • Must not be in contact with any electrical part. • Must not be rated higher than the working pressure shown on the data plate of the water heater. The Discharge Line: • Must not be smaller than the pipe size of the relief valve or have any reducing coupling installed in the discharge line. • Must not be capped, blocked, plugged, or contain any valve between the relief valve and the end of the discharge line. • Must terminate a maximum of six inches above a floor drain or external to the building. In cold climates, it is recommended that the discharge pipe be terminated at an adequate drain inside the building. • Must be capable of withstanding 250 ° F (121 oC) without distortion. • Must be installed to allow complete drainage of both the valve and discharge line. 6. Spread the slit open and slip the insulation over the cold water (inlet) pipe. Apply gentle pressure along the length of the insulation to ensure it is fully seated around the pipe. Also ensure that the base of insulation is flush with the water heater. Once seated, secure the insulation with duct tape, electrical tape, or equivalent. 7. Repeat steps 5 through 6 for the hot water (outlet) pipe. Add additional sections of pipe insulation as needed. 8. Solar Installation If this water heater is used as a solar storage heater or as a backup for the solar system, the water supply temperatures to the water heater tank may be in excess of 120 ° F (48.8° C). A mixing valve or other temperature limiting valve must be installed in the water supply line to limit the supply temperature to 120 ° F (48.8° C). Note: Solar water heating systems can often supply water with temperatures exceeding 180° F (82.2 ° C) and may result in water heater malfunction. T&P Relief Valve and Pipe Insulation" 1. 2. 3 Locate the temperature and pressure relief valve on the water heater (also known as a T&P Relief Valve, (Figure 6). Locate the slit running the length of the insulation. Spread this slit open and slip it up under the T&P Relief Valve (See Figure 6). Apply gentle pressure to the insulation to ensure it is fully seated on the T&P Relief Valve. Once sealed, secure the insulation with a section of duct tape, electrical tape, or equivalent. IMPORTANT: The insulation or tape must not block the discharge opening or hinder access to the manual relief lever. Ensure a discharge pipe is installed into the T&P valve discharge opening per the instructions manual. 4. Locate the hot water (outlet) & cold water (inlet) pipes to the water heater. 5. Locate the slit running the length of a section of pipe insulation. Figure 6 Temperature Relief Valve Electrical Requirements Electric Shock Hazard Disconnect __ Lever -_-- Replace all parts and panels before operating. ervicing.to do so can result in Failure death or electric shock. Fire Hazard Use 10 gauge solid copper wire. Use a UL approved strain relief. Connect ground wire to green ground screw. Failure to do so can result in death, fire, or electrical shock. and Pressure Installation _ power before If you lack the necessary skills required to properly install the electrical wiring to this water heater, do not proceed, but have a qualified electrician perform the installation. When making the electrical connections, always make sure: T&P Relief V_ T&P Relief Valve Drain Line T&P Relief Valve Insulation • The electrical supply has the proper overload fuse or circuit breaker protection. • Wire sizes and connections comply with all applicable codes. • Wiringisenclosed inapproved conduit(ifrequired bylocalcodes). • Thewaterheaterandelectrical supplyareproperly grounded. Alwaysreference thewiringdiagram forthecorrectelectricalconnection. Thecomplete wiringdiagram canalsobe foundonthetopofthewaterheaternearthejunctionbox cover. Wheninstalling theelectrical wiringtothewaterheater • Although thiswaterheaterisequipped with"Dry-fire" protection, besurethetankiscompletely filledwith water,andallairispurgedfromthetankbefore makinganyelectrical connections (SeeFigure7). Figure 8 Wiring Diagram Circuit i _rtGrid Wir_ Harness i , | i| Approved I Connectors Breaker _w/ / , I_---o,_. ; •, i i ",, ........... d / To 240v 1 Phase Power supply im Electrical Water H eater _" i!r!_elnd Service inal ground Figure 7 Heating Element Figure 8A Junction Box Junction Box Cover / From Home NOTE: Applying electrical power to elements that are not submerged in water will destroy them. The manufacturer will not warranty any elements damaged in this manner. , , , Check and turn off power to the electrical wiring of the water heater before making any electrical connections to the water heater. Electrical Service RedWires (3) BlackWires Remove the junction box cover that is secured by one screw (Figure 8A). Place the cover and screw aside and view the wiring diagram. Locate the four power wires inside the junction box (there will be TWO red wires and TWO black wires). Connect the electrical supply to the water heater in accordance with the local utility requirements and codes. Astandard 1/2 inch opening has been made in the junction box for the conduit connections (Figure 8A). NOTE: Use only 10 gauge solid copper wire for the electrical connections and an appropriate size double pole circuit breaker. '2" Conduit Connection Figure 8B Electronic Thermostat (ET) Electronic Thermostat Fire Hazard Use 10 gauge solid copper wire. Use a UL approved strain relief. Connect ground wire to green ground screw. Failure to do so can result in death, fire, or electrical shock. Wiring Harness (Junction Box) Wiring Harness ( ET to ESM )\ Energy Smart c_ Module (ESM) Ground , , Ground the water heater by connecting the bare copper ground wire from the home's electrical service to the green ground screw (located on the electrical junction box on top of the water heater). See Figures 8 and 8A. There are TWO black wires and TWO red wires in the water heater. The smaller red and black wires are used by the Smart Grid connector. ( Attached Wire To T-Stat Bracket Screw ) , , Connect the black power wire from the home's electrical service to the heater's TWO black wires and secure with the appropriate size wire nut. When you are done, you will have THREE black wires under one wire nut. Locate and connect the remaining power wire (usually red, but in your home this wire may be some other color) from the home's electrical service to the water heater's TWO red wires and secure with the appro priate size wire nut. When you are done, you will have THREE red wires under one wire nut (depending on the actual color of your home's electric wiring). INSTALLATION 8. Replace the junction box cover and secure with the screw removed in step 2. 9. Do not remove the Smart Grid cover from the Smart Grid connector (Figure 8A) unless this feature is being used (see the "Smart Grid Technology" section this manual). 10. Insure that the water heater is completely full of water. Proceed to water heater start up in the "Operating Your Water Heater" section of this manual. CHECKLIST Water Heater Location Water System Piping [] Centrally located with the water piping system. [] [] The flooring beneath the water heater must be able to support the weight of the water heater when filled with water. Temperature and pressure relief valve properly installed with a discharge pipe run to an adequate drain and protected from freezing (See Figure 3). [] All piping properly installed and free of leaks. [] Located indoors and in a vertical position. Protected from freezing temperatures. [] Suitable metal drain pan lines installed and piped to an adequate drain (See Figure 3). [] Provisions made to protect the area from water damage. Metal drain pan installed and piped to an adequate drain. [] Heater completely filled with water (See Figure 3). [] Closed system pressure buildup precautions installed (See "Closed System/Thermal Expansion" section). [] Mixing valve (when applicable) installed per manufacturer's instructions (see Figure 4). [] Sufficient room to service the water heater. [] The site location must be free from any corrosive elements in the atmosphere such as sulfur, fluorine, and chlorine. These elements are found in aerosol sprays, detergents, bleaches, cleaning solvents, air fresheners, paint, and varnish removers, refrigerants, and many other commercial and household products. Electrical Connections [] Wiring and connections comply with all applicable codes. [] Water heater and electrical supply are properly grounded. [] Proper overload fuse or circuit breaker protection installed. OPERATING YOUR WATER HEATER Water Temperature Regulation Water Heater Start-Up 1. Carefully read and understand the section, "Water Temperature Regulation" section of this manual. If the instructions are not clear, contact a qualified person. 2. Make sure the water heater has been properly installed. See "Installing Your Water Heater" section. 3. Completely fill the tank water, Open faucet to allow air to purge (see page 5, step 7). 4. After the tank is completely filled with water, turn on power to the water heater at the breaker panel. , 6. Power to the water heater will allow the water heater to run a system diagnostic. This typically takes eight minutes. Once complete, proceed to the next step. NOTE: if the system diagnostic yields any codes, reference the Diagnostic Code section in this manual. Water temperature over 125°F can cause severe burns instantly or death from scalds. Adjust the thermostat to the desired temperature setting as described under "Adjusting the User Interface Module/Operational Modes" section. Children, disabled, and elderly are at highest risk of being scalded. Feel water before bathing Figure 9 Temperature limiting recommended. IMPORTANT: Operation of this water heater without access doors or insulation could result in much higher water temperatures than the desired set point, increasing the risk of scald injury. Do not operate water heater with the accessdoors or insulation removed. Access Doors or showering. valves are The water heater is adjusted to a temperature setting of no higher than 120° F when shipped from the factory. Water temperature can be regulated by adjusting the Energy Smarte Module to the preferred setting as shown in "Adjusting the Energy Smart ¢ Module/Operational Mode". The preferred starting point is 120° R There is a hot water scald potential if the temperature set point is set too high. Ca < "-El Important: Adjusting the temperature past 120° F on the Energy SmarP Module will increase the risk of scald injury in the times shown below. The use of a mixing valve is recommended. IMPORTANT: Do not attempt to operate this water heater if the temperature sensor(s), electronic control board, or surrounding insulation has been exposed to water in any way. Immediately call a qualified service technician to inspect the water heater and replace any temperature sensor(s), electronic control board, or insulation that has been exposed to water. Do not attempt to repair these parts. Water heaters subjected to flood conditions or any time the temperature sensor(s) or electronic thermostat have been submerged in water require replacement of the entire water heater. 110°F (43°C) 116°F (47°C) 116°F (47°C) Safety Shut-Off shower (pain temp.) threshold) 35 minutes 45 minutes 122°F (50°C) 1 minute 5 minutes 131°F (55°C) 5 seconds 25 seconds 140°F (60°C) 2 seconds 5 seconds 149°F (65°C) 1 second 2 seconds 154°F (68°C) (U.S. Govemment This water heater is designed to automatically shut-off in the event that the water temperature exceeds 180 ° F (82.2° C). A temperature limit switch, or ECO (Energy Cut Off), is used to shut off the power to the system if the water temperature exceeds 180 ° F or 82.2 ° C. The ECO can be reset by firmly pushing in the red reset button located on the electronic thermostat (see Figure 10Aon page 12). If the ECO continues to shut-off the water heater contact a qualified person. (normal instantaneous Memorandum, 1 second C.RS.C., Peter L Armstrong, Sept. 15,1978) When leaving your home for extended periods (vacations, etc.) set the water heater to Vacation Mode. See "Adjusting the Energy Smarte Module/Operational Modes" section. This will maintain the water at low temperatures with minimum energy losses and prevent the tank from freezing during cold weather. NOTE: When returning from an extended stay remember to set the water heater back to the desired Operational Mode. 10 Adjusting the Energy Smart ®Module/Operational Modes Water Temperature Adjustment IMPORTANT: Before attempting to adjust the thermostat, read the "Water Temperature Regulation" section on page 10. If the instructions are not clear, contact a qualified person. The water temperature can be adjusted from 80 ° F to 150 ° F. Use the Up and Down Buttons | desired temperature. Operating Mode Descriptions © to set the Figure 10: Energy Smart '_ Module (ESM) The operating modes can be changed by touching the desired mode icon on the Energy SmarP Module (See Figure 10). NOTE: All buttons on the Energy Smart ¢ Module are touch sensitive and require only a light touch to actuate. ENERGY SMART ®- This mode is used to save energy by monitoring usage and adjusting the set point to match the water draw usage pattern (Temperature set point can be changed). | Operational Mode Buttons Element Water Temperature Functioning Icon \ j STANDARD - Pressing this button will allow the temperature set point to be set directly. Set Point Control Lock ® ® VACATION MODE - The controller adjusts the water temperature to approximately 60°R This mode is recommended when the water heater is not in use for a long period of time. This mode minimizes energy consumption and prevents the water heater from freezing during cold weather. Temperature I Up (Increase) Button _ Fahrenheit/ f Celsius Temperature Display Button °F/°C E_ c=Jl ! ELEMENT Temperature Down (Decrease) Button \ LCD Display Panel Lock Button GRID ENABLED - Pressing this button will enable or disable a request for grid control (see page 13). Energy Smart _' Module (ESM) CONTROL PANEL LOCK - Holding this button for more than 3 seconds switches the lock mode on or off. When the User Module is locked, a symbol and "Lock" text will be visible on the display. i Panel Icon Electronic Thermostat. (ET) - Thisshowthe button switches the I_ °F/°C displayto set temperature in Fahrenheit or Celsius. Fault condition will display an "E" followed by two digit fault code with Alert Icon flashing. (see diagnostic code chart page 17). Element Functioning Icon -indicates power is on at either upper or lower element circuits and both are working properly. NOTE: The Electronic Thermostat (ET) is designed so that it may control the water heater without the Energy Smart ® Module (ESM) being operated, see page 12. 11 The Electronic Thermostat IMPORTANT: The Energy Smart s Module (ESM) must be removed before attempting to access the thermostat. NOTE: for the Electronic Thermostat (ET) changes to remain in effect the Energy Smart s Module (ESM) must no._[t be reconnected, also read the "Water Temperature Regulation" under the "Operating Your Water Heater" section. If the instructions are not clear, contact a qualified person. Electrical Shock Hazard Do not remove the plactic guard from over wiring. Do not touch electrical wiring. The Energy Smart s Module (ESM) is intended to serve as the primary interface for operating the water heater; however, the Electronic Thermostat (ET) may control the water heater in the absence of the Energy Smart s Module (ESM). Failure to do so can result in death or electrical shock. Figure 10A Electronic Thermostat The Electronic Thermostat consists of an electronics box that contains a low voltage power supply, the thermostat set point knob, relays to switch between the upper and lower heating elements, one control thermistor, a connector for the lower element control thermistor, microelectronics to convert the thermistor signals and perform switching and other logic functions, and a connector to tie the Electronic Thermostat (ET) to the Energy Smart s Module (ESM) located on the front of the water heater jacket. The majority of the self-diagnostics are located in the Electronic Thermostat (ET), including the dry-fire protection intelligence. The thermostat circuit is designed so that when the upper heating element calls for heat, the power is directed to that element even if the lower element is also calling for heat. Diagnostic Low Voltage Diagnostic (ET) Wiring --.--,''_ LED Light @ © Knob LED Light The Green/Red LED light indicates the status of the electronic thermostat (See Figure 10A). • Green LED will signal normal operation. The green LED will blink 2 times per second to indicate that power is applied to the upper heating element and at a faster rate (4 times per second) to indicate that the lower heating element is powered. Plastic Guard ( Remove Only After Power Is Turned Off When Replacing Element, see page 16 ) Figure 10B Electronic Thermostat • Red LED will flash error codes. If a fault is detected by the electronic thermostat, the LED light indicator will use the red LED to indicate the fault detected. The flash code sequence is to consist of 1/2 second flashes of the red LED each separated by a 1/2 second off period. Energy SmaW Module (ESM) Electronic The number of flashes indicates the fault code number. (See diagnostic code chart section in this manual). Thermostat, Thermostat After the last 1/2 second "on" period, the LED will remain off until a total of 5 seconds has elapsed for the fault indication cycle (there is a 5 seconds delay before the fault flash pattern repeats). After the 5 seconds are completed, the fault indication cycle is repeated starting with the first 1/2 second-flash. The flash sequence will be repeated as long as the fault remains. Only one fault can be declared at a time. NOTE: the green LED is turned offwhen a fault code is being displayed, even though the heater may be operating in limp mode with an element on. See diagnostic code chart section in this manual. Overriding (ET) Thermistor Wire Harness Junction Wiring Harness The Energy Smart ® Module (ESM) If the Energy Smart s Module (ESM) is not working, simply unplug the interface module and turn the set point knob on the Electronic Thermostat (ET) to the desired temperature (See Figures 10A & 10B). To replace a broken or damaged ESM module, see page 22 for ordering information. NOTE: Smart Grid will be disabled when the Energy SmarP Module (ESM) is disconnected from the junction box wiring harness. 12 Smart Grid Technology The electric Smart Grid will enable significant improvements in electric power reliability and quality through reduction of peak power demand, while providing consumers the knowledge and ability to manage their energy consumption and utility costs. According to the Department of Energy (DOE), since 1982 the growth in peak electricity demand has exceeded power transmission growth. This has caused more frequent blackouts and service interruptions, as well as an increase in the costly reserve capacity the power grid requires to meet higher peak demands. The increased demand for electrical power across the nation has also led to higher peak utility costs. Electric Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electric shock. Smart appliances are one way to help mitigate this problem. By using advanced digital communication technologies, smart appliances will be able to communicate with local power company or home energy management systems, and react accordingly to save energy and money. For example, during peak demand periods the water heater may pause or delay its power consumption and thus reduce the load on the smart utility grid. Additionally, smart appliances will also communicate with consumers to let them know how much energy they are consuming. This will eventually allow consumers to control their appliances, manage energy usage, and to ultimately save money. Figure 10C Smart Grid Connection jf jz Grid Communication _/ (May Be Supplied (May Differ j/ "-_ Adaptor By Power Company) in Appearance) Smart Grid Control (Where Available) Where available, Grid Communication Adaptors may be supplied by the local power company or purchased from leading retailers. Please contact your local power company for more information. Junction Grid Connection Box Pins To activate Smart Grid Control, remove the cover over the grid connection pins and plug in the grid communication adaptor. See Figure 10C. NOTE: use only Whirlpool - approved grid communication adaptors. This will enable the power company to communicate the peak demand periods for the water heater's power usage. Figure 10D Smart Grid Control ed/oSSing this button will enable r disable a request After this connection has been made, simply mart Grid Control press the "Grid Enabled" button to enable and/ or disable a request for grid control. See Figure 10D. Enabling this feature will allow acceptance of the power company communication of grid management requests. Disabling this feature will allow the water heater to ignore grid management requests. ENERGY SMART STANDARD VACATION GR_D ENABLED EL.I NOTE: Smart Grid will be disabled when the Energy SmarP Module (ESM) is disconnected from the junction box wiring harness (see page 12). 13 t _ GRID LOCK for _ J_ i Operational Conditions Anode Rod/Water Water Heater Sounds Odor Each water heater contains at least one anode rod, which will slowly deplete (due to electrolysis) prolonging the life of the water heater by protecting the glass-lined tank from corrosion. Adverse water quality, hotter water temperatures, high hot water usage, hydronic heating devices, and water softening methods can increase the rate of anode rod depletion. Once the anode rod is depleted, the tank will start to corrode, eventually developing a leak. During the normal operation of the water heater, sounds or noises may be heard. These noises are common and may result from the following: Certain water conditions will cause a reaction between the anode rod and the water. The most common complaint associated with the anode rod is a "rotten egg smell" produced from the presence of hydrogen sulfide gas dissolved in the water. CAUTION: Do not remove this rod permanently as it will void any warranties. A special anode rod may be available if water odor or discoloration occurs. NOTE: this rod may reduce but not eliminate water odor problems. The water supply system may require special filtration equipment from a water conditioning company to successfully eliminate all water odor problems. • The majority of the rods diameter is less than 3/8". • Significant sections of the support wire (approx. 1/3 or more of the anode rod's length) are visible. If the anode rod show signs of either or both it should be replaced (see Figure 11). NOTE: Whether re-installing or replacing the anode rod, check for any leaks and immediately correct if found. Figure 11 Anode Rod PITTED ANODE ROD EXPOSED SUPPORT WIRE _,_,k,,=_ F EXPOSED _._.. _t._ __,,_ ,_ ='_#/ _t.,._ q_ZC,_'.,L.Z'_' Sediment buildup in the tank bottom will create varying amounts of noise and may cause premature tank failure. Drain and flush the tank as directed under "Draining and Flushing". Stacking occurs when a series of short draws of hot water (3 gallons or less) are taken from the water heater tank. This causes increased cycling of the heater elements and can result in increased water temperatures at the hot water outlet. An anti-scald device is recommended in the hot water supply line to reduce the risk of scald injury. Use of a mixing valve is encouraged. The following are typical (but not all) signs of a depleted anode rod: _ 2. Certain water usage patterns can cause the water temperature to exceed the thermostat setting. This is known as "Stacking". The anode rod should be inspected after a maximum of three years and annually thereafter until the condition of the anode rod dictates its replacement. NOTE: artificially softened water requires the anode rod to be inspected annually. ; Normal expansion and contraction of metal parts during periods of heat-up and cool-down. Stacking Artificially softened water is exceedingly corrosive because the process substitutes sodium ions for magnesium and calcium ions. The use of a water softener may decrease the life of the water heater tank. _--_" _ 1. SUPPORT WIRE ,._ _ See "Replacing the Anode Rod" in the maintenance section page 15. 14 MAINTENANCE OF YOUR WATER HEATER If you lack the necessary skills required to properly service this water heater or you have difficulty following the instructions, you should not proceed but have a qualified person perform the maintenance of this water heater. Draining and Flushing Temperature Relief Valve It is recommended that the tank be drained and flushed every 6 months to remove sediment which may buildup during operation. The water heater should be drained if being shut down during freezing temperatures. To drain the tank, perform the following steps: Explosion 1. Turn off the power to water heater. 2. Open a nearby hot water faucet until the water is no longer hot. , 4. , , 7. Close the cold water inlet valve. Connect a hose to the drain valve and terminate it to an adequate drain or external to the building. • Properly sized temperaturepressure relief valve must be installed in opening provided. Open the water heater drain valve and allow all the water to drain from the tank. Flush the tank with water as needed to remove sediment. • Can result in overheating and excessive tank pressure. Close the drain valve and refill the tank (open the cold water inlet valve), and restart the heater as directed in this manual. CAUTION: Do not turn on power to the water heater unless it is completely filled with water. To ensure that the tank is full, open a hot water faucet and allow water to run until the air is purged and the water flows uninterrupted from the faucet. • Can cause serious injury or death. Manually operate the temperature and pressure relief valve at least once a year to make sure it is working properly. To prevent water Figure 12 damage, the valve must | Temperature and Pressure be properly connected to | Relief Valve | _, Manual Relief a discharge line which terminates at an adequate drain. Turn the electrical power on to turn the water heater on. NOTE: the water heater will conduct a system diagnostic prior to operation. I1( I,,,v Standing clear of the outlet (discharged water may be hot), slowly lift and release the lever handle on the Discharge line to drain temperature and pressure relief valve to allow the valve to operate freely and return to its closed position. If the valve fails to completely reset and continues to release water, immediately disconnect the electrical power, close the cold water inlet valve and call a qualified person. Replacing the Anode Rod 2. , , Turn off the power to the water heater. Shut off the water supply and open a nearby hot water faucet to depressurize the water tank. Drain approximately 5 gallons of water from the tank. (Refer to "Draining and Flushing" for proper procedures.) Close drain valve. Remove the old anode rod (See Figure 11). 5. Use Teflon ®tape or approved pipe sealant on threads and install new anode rod. 6. Turn on the water supply and open a nearby hot water faucet to purge all air from the water system. 7. Restart the heater as directed in this manual. Turn the electrical power on to turn the water heater on. NOTE: the water heater will conduct a system diagnostic prior to operation. See the "Repair Parts Illustration" for anode rod location on page 22. Teflon _ is a registered trademark of E.I. Du Pont De Nemours Hazard Temperature-pressure relief valve must comply with ANSI Z21.22-CSA 4.4 and ASME code. If the water heater is going to be shut down for an extended period, the drain valve should be left open. , and Pressure and Company. 15 Heating Element Replacement Figure 14 Element and Thermistor Lower Thermistor Sensor (Must Have Good Contact With Tank, Sensor Electrical Disconnect servicing. Shock Hazard 2. Drain the water heater as directed under "Draining and Flushing" section. Remove the access cover(s), then remove the insulation and element cover(s). Remove the plastic guard covering electric wiring. 4. /1 --._ Element /1 Spud _ { /I/1 -- _ _ /1 /1 /1 /1 Gasket Tank j Replacement heating elements must be of the same style and voltage/wattage rating as the ones originally in the water heater. This information can be found on the flange or terminal block of the element or on the water heater data plate. Turn off the electric power to the water heater. /1 Sensor Bracket _.1_ Sirew-in 1. 4_ Element) power before Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 3. Check After Replacing , , 9. Disconnect the electric wires from the heating element (See Figure 13). Remove the screw-in element by turning the element counterclockwise with an SAE 1-1/2inch socket wrench or use an element wrench. Remove the existing gasket. /I Close the drain valve. Open the nearest hot water faucet and allow the tank to fill completely with water. To purge the lines of any excess air and sediment debris, keep the hot water faucet open for 3 minutes after a constant flow of water is obtained. Close the faucet. Check for leaks around element(s) and other connections. Connect the electric wires to the heater element. make sure all wires are secure. Reinstall plastic guard covering wiring. 10. Replace the insulation and access door(s). IMPORTANT:Operation of this water heater without access doors or insulation could result in much higher temperatures than the desired set point, increasing the risk of scald injury. Do not operate water heater with the access doors or insulation removed. Figure 13 Element Wiring Connection Lower Thermistor Sensor 11. Reconnect the electric power to the water heater. 12. Turn the electrical power on to turn the water heater on. NOTE: the water heater will conduct a system diagnostic prior to operation. Ground Wire (green) Element Screws 5. Clean the area with a soft cloth to remove any debris where the gasket fits to the tank. If replacing the bottom element, remove the accumulated sediment on the bottom of the tank. Refer to "Draining and Flushing." 6. Make sure the replacement element has the correct voltage and wattage rating. Lubricate the new gasket with a few drops of dishwashing soap, position the new gasket on the element and insert it into the water heater tank (See Figure 14). Tighten the element by turning it clockwise until secure. 16 Diagnostic Code Chart Energy Smart ® Module (ESM) ( IMPORTANT: Before attempting to adjust the thermostat, read the "Water Temperature Regulation" section page 10. ENERGY SMART The Electronic Thermostat (ET) is designed so that it may control the water heater without the Energy SmarP Module (ESM) being operated, see page 12. STANDARD VACATION GR_O E.AB[ED I EI Error Code ! -Alert Icon If the instructions are not clear, contact a qualified person. U.F q INDICATES (ESM) ERROR CODE CORRECTIVE ACTION* E01 with an alert Icon flashing. Dry-fire, electrical power on with the tank not completely full of water. 1. Turn off electrical power at breaker, add water. 2. Turn on electrical power at breaker. 3. See "Water Heater Start-Up" on page 10. E02 with an alert Icon flashing. Water temperature 1. 2. 3. 4. E03 with an alert Icon flashing. Upper thermistor sensor failure. (Note: Upper thermistor sensor is part of the ET) 1. Turn off electrical power at the breaker. 2. Replace Electronic Thermostat (ET). 3. Turn on electrical power at breaker. E04 with an alert Icon flashing. Upper element circuit failure. (Note: Lower element is still operable) 1. Turn off electrical power at the breaker. 2. Check element circuits for resistance of 5-25 ohms (replace if required). 3. Check wires at elements and Electronic Thermostat (ET) for damage. If this 4 flashes condition continues, replace Electronic Thermostat (ET). 4. Turn on electrical power at breaker. E05 with an alert Icon flashing. Lower element circuit failure. 1. Turn off electrical power at the breaker. 2. Check element circuits for resistance of 5-25 ohms (replace if required). 3. Check wires at elements and Electronic Thermostat (ET) for damage. If this 5 flashes condition continues, replace Electronic Thermostat (ET). 4. Turn on electrical power at breaker. exceeded (Note: Upper element E06 with an alert Icon flashing. Electronic Thermostat (Internal processor). E07 with an alert Icon flashing. Lower thermistor E08 E09 with an alert Icon flashing. with an alert Icon flashing. Energy Smart failure. Electronic ® high limit. is still operable) (ET) failure sensor failure. Module(ESM) Thermostat (ET) error. Turn off electrical power at the breaker. Press the reset button (see Figure 10A). Turn on electrical power at breaker. If error returns call a service technician for assistance. 1. Turn off electrical power at the breaker. Now turn on electrical power to see if error clears. If error has not cleared, replace Electronic Thermostat (ET). 2. Turn on electrical power at breaker. 1. 2. 3. 4. Turn off electrical power at the breaker. Check electrical connections at Electronic Replace Lower Thermistor Sensor. Turn on electrical power at breaker. (ET). 1. 2. 3. 4. Turn off electrical power. Check wires at the interface module for damage. If this 8 flashes condition continues, replace module (ESM). See "Overriding The Interface Module (ESM)" by unplugging from the Electronic Thermostat (ET) on page 12. NOTE: Electronic Thermostat (ET) will continue to be operate, hot water will still be available. 5. Turn on electrical power at breaker. 1. Turn off electrical power. El0 2. Check wiring at Electronic Thermostat 3. Turn on electrical power at breaker. Ell 4. If this code flashes condition Thermostat (ET). E12 Thermostat continues, (ET) for damage. replace the Electronic *These instructions are brief and intended as guidance for a qualified person. If you lack the necessary skills to perform these procedures call 1-877-817-6750 for assistance. 17 INDICATES (ESM) ERROR CODE E51 with an alert Icon flashing. A failure to communicate E71 with an alert Icon flashing. with an alert Icon flashing. CORRECTIVE ACTION* 1. Turn off electrical power at the breaker, check all electrical and wiring for damage. 2. Replace the Electronic Thermostat (ET). 3. Turn on electrical power at breaker. connections, Energy Smart® Module (ESM) is receiving the wrong data from the Electronic Thermostat (ET). 1. Turn off electrical power at the breaker, check all electrical and wiring for damage. connections, Energy Smart® Module failure. 1. Turn off electrical power at the breaker, check all electrical and wiring for damage. 2. Turn on electrical power at breaker. 3. If error returns call service technician for assistance. Thermostat E52 with the Electronic (ET). (ESM) thermistor 2. Replace the Energy Smart® Module (ESM), if this does not correct the problem, also replace Electronic Thermostat (ET). *These instructions are brief and intended as guidance for a qualified person. If you lack the necessary skills to perform these procedures call 1-877-817-6750 for assistance. 18 connections, Diagnostic Code Chart Electronic Thermostat (ET) IMPORTANT: Before attempting to adjust the thermostat, read the "Water Temperature Regulation" section page 10. Setpoint Knob Diag LED Light The Electronic Thermostat (ET) is designed so that it may control the water heater without the Energy Smart_ Module (ESM) being operated, see page 12. Electrical Shock Hazard Do not remove the plactic guard from over wiring. Do not touch electrical wiring. If the instructions are not clear, contact a qualified person. (ESM) ERROR CODE (ET) DIAGNOSTIC LIGHT ON (Green E02 E03 E04 E05 E06 E07 INDICATES CORRECTIVE Normal operation. None No electrical or diagnostic 1. Check for blown fuses or tripped breaker. 2. If diagnostic LED light is burned out, replace (ET). power to control board LED light burned out. 1 FLASH Dry-fire, (Red) tank not completely 2 FLASHES Water temperature (Red) limit. 3 FLASHES Upper thermistor (Red) (Note: Upper thermistor part of the ET) 4 FLASHES Upper element (Red) (Note: Lower element 5 FLASHES Lower element (Red) (Note: Upper element is still operable) 6 FLASHES (Red) Electronic Thermostat (Internal processor). 7 FLASHES Lower thermistor 8 FLASHES (Red) ACTION* LED electrical power on with the full of water. exceeded high 1. Turn off electrical Electronic Thermostat power at breaker, add water. 2. Turn on electrical power at breaker. 3. See "Water Heater Start-Up" on page 10. 1. Turn off electrical power at the breaker. 2. Press the reset button (see Figure 10A). 3. Turn on electrical power at breaker. 4. If error returns call a service technician for assistance. sensor failure. sensor is circuit failure. is still operable) circuit failure. (ET) failure sensor failure. (Red) E08 Failure to do so can result in death or electrical shock. -- Flash) NO LIGHT E01 Plastic Guard Energy Smart ® Interface Module(ESM) failure. 1. Turn off electrical power at the breaker. 2. Replace Electronic Thermostat (ET). 3. Turn on electrical power at breaker. 1. Turn off electrical power at the breaker. 2. Check element circuits for resistance of 5-25 ohms (replace if required). 3. Check wires at elements and Electronic Thermostat (ET) for damage. If this 4 flashes condition continues, replace Electronic Thermostat (ET). 4. Turn on electrical power at breaker. 1. Turn off electrical power at the breaker. 2. Check element circuits for resistance of 5-25 ohms (replace if required). 3. Check wires at elements and Electronic Thermostat (ET) for damage. If this 5 flashes condition continues, replace Electronic Thermostat (ET). 4. Turn on electrical power at breaker. 1. Turn off electrical power at the breaker. Now turn on electrical power to see if error clears. If error has not cleared, replace Electronic Thermostat (ET). 2. Turn on electrical power at breaker. 1. 2. 3. 4. Turn off electrical power at the breaker. Check electrical connections at Electronic Thermostat Replace Lower Thermistor Sensor. Turn on electrical power at breaker. 1. Turn off electrical power. 2. Check wires at the interface (ET). module for damage. 3. If this 8 flashes condition continues, replace module (ESM). 4. See "Overriding The Interface Module (ESM)" by unplugging from the Electronic Thermostat (ET) on page 12. NOTE: Electronic Thermostat (ET) will continue to be operate, hot water will still be available. 5. Turn on electrical power at breaker. *These instructions are brief and intended as guidance for a qualified person. If you lack the necessary skills to perform these procedures call 1-877-817-6750 for assistance. 19 (ESM) ERROR CODE (ET) DIAGNOSTIC INDICATES E9 9, 10, 11 or 12 FLASHES El0 (Red) Ell E12 CORRECTIVE ACTION* LED Electronic Thermostat (ET) error 1. 2. 3. 4. Turn off electrical power. Check wiring at Electronic Thermostat (ET) for damage. Turn on electrical power at breaker. If this code flashes condition continues, replace the Electronic Thermostat (ET). *These instructions are brief and intended as guidance for a qualified person. If you lack the necessary skills to perform these procedures call 1-877-817-6750 for assistance. 2O Troubleshooting Chart PROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTION* NO HOT WATER 1. No power to heater. 2. High temperature limit shut-down. 3. Defective sensor. 1. Refer to "E02" of Diagnostic Code Chart- page 17. 2. Refer to "E03 or E07" of Diagnostic Code Chart- page 17. 3. Refer to "No Light" of Diagnostic Code Chart- page 19. INSUFFICIENT 1. 2. 3. 4. 5. 6. 7. Defective lower element. Temperature set too low. Sediment or lime in tank. Defective Dip Tube. Heater too small for job. Wrong piping connections. Leaking faucets and/or plumbing system. 8. Wasted hot water. 9. Long runs of exposed pipe. 10.Hot water piping on outside wall. 1. 2. 3. 4. 5. 6. 7. 1. 2. 3. 4. 1. 2. 3. 4. Lower Drain, Install Repair 5. 6. 7. 8. Advise customer. Insulate piping. Insulate piping. Replace elements. HOT WATER HIGH OPERATION COSTS 5. 6. 7. 8. Temperature set too high. Sediment or lime in tank. Heater too small for job. Leaking faucets and/or plumbing system. Wasted hot water. Long runs of exposed piping. Hot water piping in exposed wall. Elements covered with sediment or lime. Refer to "E05" of Diagnostic Code Chart- page 17. Set temperature to desired setting. Drain, determine if water treatment is needed. Replace Dip Tube. Check and Install adequate water heater. Correct piping. Repair faucets and any leaks in the plumbing system. 8. Reduce hot water usage. 9. Insulate piping. 10.Insulate piping. temperature control or change to Energy Smart ® Mode. Flush-Provide water treatment if needed. adequate heater. faucets and any leaks in the plumbing system. SLOW HOT WATER RECOVERY 1. Upper element defective. 2. Leaking faucets and/or plumbing system. 1. Refer to "E04" of Diagnostic Code Chart- page 17. 2. Repair faucets and any leaks in the plumbing system. DRIP FROM T&P VALVE 1. Excessive water pressure. 2. Closed system. 3. Defective T&P valve. 1. Use pressure reducing valve and pressure relief valve (See page 6). 2. See page 6, "Closed System/Thermal Expansion". 3. Replace T&P valve. 1. Sulfides in the water. 1. See page 14, "Anode Rod/Water WATER ODOR Odor". *These instructions are brief and intended as guidance for a qualified person. If you lack the necessary skills to perform these procedures call 1-877-817-6750 for assistance. 21 REPAIR PARTS ILLUSTRATION @ ® Repair Parts ITEM PARTS DESCRIPTION No. Repair parts may be ordered through your plumber, local distributor, home improvement center, or by calling 1-877-817-6750. When ordering repair parts, always give the following information: 1. Model, serial and product number 2. Item number 3. Parts description Repair Parts List Legend 4)' Special anode rod (See page 14) • Temperature and Pressure Relief Valve is required, but may not be factory installed. A Specify element type when ordering. 22 1 ENERGY 2 UPPER SMART MODULE ELEMENT h_, 3 ELEMENT 4 ELECTRONIC 5 ACCESS (ESM) W/WIRING HARNESS GASKET THERMOSTAT (ET) DOOR 6 LOWER ELEMENT 7 DRAIN 8 TEMPERATURE 9 JUNCTION 10 NIPPLE 11 HEAT TRAP 12 DIP TUBE 13 ANODE 14 THERMISTOR 15 SMART A VALVE AND PRESSURE RELIEF BOX COVER ROD • SENSOR GRID WIRE HARNESS ASSEMBLY VALVE • THERMOSTAT WIRING DIAGRAM FUSEDDISCONNECT OR CIRCUITBREAKER :.i-'.i BRANCH CIRCUIT g Nj Based on N.E.C. ELECTRONIC THERMOSTAT(ET) ® WATT LOAD ® @ a-- BLUE o_ UPPER_ ELEMENT"_,.#t..1 p,n TEMPERATURE SENSOR Recommend Over Current Protection Rating 120 V 15 20 30 30 B--1500" 2000 2500 3000 3500 4000 4500 5000 5500 SIZING GUIDE NFPA NO. 70 - 1999 208 V 15 15 15 20 20 25 30 30 240 V 15 15 15 15 20 20 25 30 30 Wattages less than 1500 may be wired 15 amp protection. BLUE _ i \ BLACK I I J LOWER _ ELEMENT MODULE(ESM) ENERGYSMART k i d_l -GROUND SCREW ELECTRICAL SERVICE GROUND 319165-000G 23 Copper Wire Size AWG Based on N.E.C. Table310- 16 (60°C) 120 208 240 V V V 12 14 14 10 14 14 10 14 14 8 12 12 10 12 10 10 10 10 10 10 10 14 gage with a maximum ® Registered trademark/TM trademark of Whirlpool, U.S.A. © 2011 Whirlpool Corporation. All rights reserved. Energy Smart® is a trademark of American Water Heater Company Manufactured under license by American Water Heater Company, Tennessee. Warranty provided by manufacturer.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 24 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Sat Mar 29 03:29:30 2014 Author : Title : Subject :EXIF Metadata provided by EXIF.tools