Whirlpool LTE5243DQ3 User Manual LAUNDRY CENTER Manuals And Guides L0412415
WHIRLPOOL Laundry Centers Manual L0412415 WHIRLPOOL Laundry Centers Owner's Manual, WHIRLPOOL Laundry Centers installation guides
User Manual: Whirlpool LTE5243DQ3 LTE5243DQ3 WHIRLPOOL LAUNDRY CENTER - Manuals and Guides View the owners manual for your WHIRLPOOL LAUNDRY CENTER #LTE5243DQ3. Home:Laundry & Garment Care Parts:Whirlpool Parts:Whirlpool LAUNDRY CENTER Manual
Open the PDF directly: View PDF
.
Page Count: 16
| Download | |
| Open PDF In Browser | View PDF |
24"(61CM) ELECTRIC WASHER/DRYER
INSTAILATION INSTRUCTIONS
Tableof Contents
WASHER/DRYER
SAFETY .............................
1
Remove Foam Packing .......................................
Connect Drain Hose ............................................
11
11
Connect Inlet Hoses ............................................
Secure Drain Hose ...............................................
12
13
2
4
Plan Vent System ................................................
Install Vent System ..............................................
13
14
Electrical Requirements ................................ 4
Venting Requirements ................................. 10
Level Washer/Dryer .............................................
Connect Vent .......................................................
15
15
Install Leveling Legs ....................................
Complete
15
INSTALLATION INSTRUCTIONS ................... 2
Tools and Par_s ............................................. 2
Alternate Par_s ...............................................
2
Location Requirements ................................
Drain System .................................................
11
Installation ...........................................
WASHER/DRYER
SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
8542748A
INSTALLATION
INSTRUCTIONS
Gather the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools
listed here.
Your installation may require additional parts. For ordering
information, please refer to the toll free phone numbers on the
front page of your "Washer/Dryer User Instructions."
Tools needed:.
#2 Phillips and flat-blade
screwdriver
•
Adjustable wrench that
opens to 1" (2.5 cm) or
9/16"(14 mm) open-end
wrench (for adjusting
dryer feet)
•
Knife
•
Vent clamps
•
Caulking gun and
compound (for installing
new exhaust vent)
1/4"nut driver or socket
wrench
•
Pliers
•
Scissors
Wood block (for leveling)
Ruler or measuring tape
•
Tin snips (for new vent
installations)
Level
•
•
Wire stripper (direct wire
installations)
Parts supplied:
Remove parts package from the washer basket. Check that all
parts were included.
B
E
C
D
If You Have
You Will Need to Buy
Laundry tub or
standpipe taller than
96" (2.4 m)
Sump pump system (if not already
available)
1" (2.5 cm) diameter
standpipe
2" (5 cm) diameter to 1" (2.5 cm)
diameter standpipe adapter, Part
Number 3363920
Overhead sewer
Standard 20 gal. (76 L) 34" (86.4 cm)
tall drain tub or utility sink and sump
pump (available from local plumbing
suppliers)
Floor drain
Siphon break, Part Number 285320,
additional drain hose, Part Number
285702 and connector kit,
Part Number 285442
Drain hose too short
Drain hose, Part Number 285664 and
connector kit, Part Number 285442
Lint clogged drain
Drain protector, Part Number 367031
Water faucets
beyond reach of fill
hoses
2 longer water fill hoses:
6 ft (1.8 m) Part Number 76314,
10 ft (3.0 m) Part Number 350008
tJ F
A. Water inlet hoses (2)
B. Inlet hose flat washers (4)
C. Rear leveling legs (2)
D. Front leveling legs (2)
E. Plastic strap
F Drain hose
G. Yellow, single wire hose clamp
H. Sliver, double wire hose clamp
Parts needed:
Check local codes. Check existing electrical supply and venting,
and see "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
Explosion
Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Mobile home installations require metal exhaust system hardware
available for purchase from the dealer from whom you purchased
your washer/dryer. For further information, please reference the
"Assistance or Service" section of your "Washer/Dryer User
Instructions."
Failure to do so can result in death, e×pBosion, or fire.
You will need
•
A location that allows for proper exhaust installation. See
"Venting Requirements."
•
Aseparate30-amp
•
A grounded electrical outlet located within 2 ft (61 cm) of
either side of the washer/dryer. See "Electrical Requirements."
circuit.
•
A sturdy floor to support the washer/dryer weight (washer/
dryer, water and load) of 500 Ibs (226.8 kg).
Minimum installation spacing for recessed area or closet
installation
•
A level floor with a maximum slope of 1" (2.5 cm) under entire
washer/dryer. Clothes may not tumble properly and automatic
sensor cycles may not operate correctly if washer/dryer is not
level. Installing on carpet is not recommended.
The following dimensions shown are for the minimum spacings
allowed.
•
Additional spacing should be considered for ease of
installation and servicing.
•
A water heater set to deliver 120°F (49°C) water to the washer.
•
•
Hot and cold water faucets located within 4 ft (1.2 m) of the
hot and cold water fill valves, and water pressure of 5-100 psi
(34.5-689.6 kPa).
Additional clearances might be required for wall, door and
floor moldings.
•
Additional spacing of 1" (2.5 cm) on all sides of the washer/
dryer is recommended to reduce noise transfer.
•
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
•
Rear clearance may be 0" when house exhaust system is lined
up directly with dryer exhaust.
The washer/dryer must not be installed or stored in an area where
it will be exposed to water and/or weather.
Do not operate your washer in temperatures at or below 32°F
(0°C). Some water can remain in the washer and can cause
damage in low temperatures. See "Washer/Dryer Care" in the
"Washer/Dryer User Instructions" for winterizing information.
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. This can result in longer drying times.
Check code requirements. Some codes limit, or do not permit,
installation of the washer/dryer in garages, closets, mobile homes,
or sleeping quarters. Contact your local building inspector.
Installation
0"
b (ocm) 1--
_'(7,6cra}
010crr¢)|
©
oo
o_
k:2
I
#
Clearances
24in=a
The location must be large enough to allow the dryer door to open
fully.
Washer/Dryer
0"÷]_ 23_'q_l<- 0"
(o®} (6o._40m}(ocm}
A
Dimensions
71 _A"
*Most installations require a minimum 51/2'' (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
<- 5'/a"
04®}
--
B
C
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
15%"
(39,05 cm)
{182=25 cm)
{25 C_n){69,22 cm)
Mobile Home - Additional Installation Requirements
This washer/dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
Safety, Title 24, HUD Part 280).
Mobile home installations require:
and
•
Metal exhaust system hardware which is available for
purchase from your dealer.
•
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
Thewasher/dryer
canbeinstalled
usingthestandpipe
drain
system
(floororwall),thelaundry
tubdrainsystem,
orthefloor
drainsystem.
Select
thedrainhoseinstallation
method
youneed.
See"Alternate
Parts."
Standpipe drain system - wall or floor (views A & B)
The standpipe drain requires a minimum diameter standpipe of
2" (5 cm). The minimum carry-away capacity can be no less than
17 gal. (64 L) per minute. A 2" (5 cm) diameter to 1" (2.5 cm)
diameter standpipe adapter kit is available. See "Alternate Parts."
The top of the standpipe must be at least 39" (99 cm) high and no
higher than 96" (2.4 m) from the bottom of the washer.
39,,1
(99 era}
Laundry tub drain system (view C)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top
of the laundry tub must be at least 34" (86.4 cm) above the floor
and no higher than 96" (2.4 m) from the bottom of the washer.
Floor drain system (view D)
The floor drain system requires a siphon break that may be
purchased separately. See "Alternate Parts."
The siphon break must be a minimum of 28" (71 cm) from the
bottom of the washer. Additional hoses might be needed.
It is your responsibility
•
To contact a qualified electrical installer.
•
To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSl/NFPA
70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.
•
To supply the required 3 or 4 wire, single phase, 120/240-volt,
60-Hz., AC-only electrical supply (or 3 or 4 wire, 120/208-volt
electrical supply, if specified on the serial/rating plate) on a
separate 30-amp circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
•
Do not use an extension cord.
•
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Electrical Connection
To properly install your washer/dryer, you must determine the type
of electrical connection you will be using and follow the
instructions provided for it here.
•
This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The green cabinet-grounding
conductor is permanently connected to the neutral conductor
(white wire) within the dryer. If the dryer is installed with a
4-wire electrical supply connection, the green cabinetgrounding conductor must be removed from the external
ground connector (green screw), and secured under the
neutral terminal (center or white wire) of the terminal block.
When the green cabinet-grounding conductor is secured
under the neutral terminal (center or white wire) of the terminal
block, the dryer cabinet is isolated from the neutral conductor.
•
If local codes do not permit the connection of a cabinet
ground connector to the neutral wire, see "Optional 3-wire
connection" section.
•
Use a 4-wire conductor cord when the dryer is installed in a
mobile home or an area where local codes do not permit
grounding through the neutral.
If using a power supply cord:
D
Use a UL listed power supply cord kit marked for use with clothes
dryers. The kit should contain:
•
A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be at
least 4 ft (1.22 m) long. The wires that connect to the dryer
must end in ring terminals or spade terminals with upturned
ends.
•
A UL listed strain relief.
If your outlet looks like this:
•
At least 5 ft (1.52 m) long.
GROUNDING INSTRUCTIONS
4-wire receptacle
(14-30R)
Then choose a 4-wire power supply cord with ring or spade
terminals and UL listed strain relief. The 4-wire power supply cord,
at least 4 ft (1.22 m) long, must have 4, 10-gauge copper wires
and match a 4-wire receptacle of NEMA Type 14-30R. The ground
wire (ground conductor) may be either green or bare. The neutral
conductor must be identified by a white cover.
If your outlet looks like this:
3-wire receptacle (10-30R)
Then choose a 3-wire power supply cord with ring or spade
terminals and UL listed strain relief. The 3-wire power supply cord,
at least 4 ft (1.22 m) long, must have 3, 10-gauge copper wires
and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
•
Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), protected with flexible metallic conduit. All
current-carrying wires must be insulated.
•
10-gauge solid copper wire (do not use aluminum).
[] For a grounded, cord-connected washer/dryer:
This washer/dryer must be grounded. Hnthe event of
malfunction or breakdown, grounding wilI reduce the risk of
electric shock by providing a path of least resistance for
electric current. This washer/dryer uses a cord having an
equipment-grounding
conductor and a grounding plug. The
plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with alI local
codes and ordinances.
[] For a permanently connected washer/dryer:
This washer/dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on
the washer/dryer.
WARNmNG:
Hmproper connection of the equipmentgrounding conductor can result in a risk of eiectric shock.
Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the washer/dryer
is properly grounded. Do not modify the plug on the power
supply cord: if it wilI not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE
THESE
INSTRUCTIONS
Power
Supply
Cord
DirectWire
Fire Hazard
Fire Hazard
Use a new UL _isted 30 amp power supply cord.
Use 10 gauge solid copper
Use a UL _isted strain relief,
Use a UL listed strain
Disconnect
power before making
e_ectdcal connections.
Disconnect
Connect neutra_ wire (white or center wire) to center
terminat (silver),
Ground wire (green or bare wire) must be connected
green ground connector.
Connect remaining
2 terminals (go_d).
Securely tighten
to
Disconnect power.
Remove the hold-down
Connect remaining
2 terminals (gold).
connections,
Securety tighten
to
2 supply wires to remaining
a_ e_ectdca{ connections.
Failure to do so can result in death, fire, or
electrical shock.
3.
screw and terminal block cover,
power before making e_ectrica_ connections.
Ground wire (green or bare wire) must be connected
green ground connector.
Failure to do so can result in death, fire, or
e_ectrical shock,
1.
2.
retief.
Connect neutra_ wire (white or center wire) to center
terminal (silver).
2 supply wires to remaining
aimelectrical
wire.
Assemble a 3/4"(1.9 cm) UL listed strain relief (UL marking on
strain relief) into the hole below the terminal block opening.
Tighten strain relief screws just enough to hold the two clamp
sections together. Put power supply cord through the strain
relief. The strain relief should have a tight fit with the dryer
cabinet.
Now complete installation following instructions for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
A. Center silver-colored terminal block screw
B. Hold-down screw
C. Terminal block cover
D. Internal ground conductor
screw
Electrical Connection Options
If your home has:
4-wire receptacle
(NEMA Type 14-30R)
Remove neutral grounding wire (green with yellow stripes)
from internal ground conductor screw. Fasten it under center,
silver-colored terminal block screw.
And you will be
connecting to:
Go to Section
A UL listed,
120/240 volt
4-wire connection:
Power supply cord
A
30-amp, dryer
power
supply
minimum,
cord*
4-wire direct
A fused
disconnect or
circuit breaker
box*
4-wire connection:
Direct Wire
A UL listed,
120/240 volt
3-wire connection:
J
C
3-wire receptacle
(NEMA type 10-30R)
3-wire direct
A fused
disconnect or
circuit breaker
box*
terminal block screw
B. Neutral grounding wire (green with yellow stripes)
C. internal ground conductor screw
30-amp, dryer
power supply
minimum,
cord*
_)
A. Center silver-colored
Power supply cord
3.
3-wire connection:
Direct Wire
4.
Move the green painted screw from the internal to the external
ground conductor location. Connect ground wire (green or
bare) of power supply cord to external ground conductor
screw. Tighten screw.
Connect neutral wire (white or center wire) of power supply
cord under center screw of the terminal block. Tighten screw.
B
?'
9
*If local codes do not permit the connection of a frame-grounding
conductor to the neutral wire, go to "Optional 3-wire connection"
section.
4-wire connection: Power supply cord
IMPORTANT: A 4-wire connection is required for all mobile
homes and where local codes do not permit the use of 3-wire
connections.
F
B
G
C
D
E
A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
F. _" (1.9 cm) UL llsted strain relief
G. Ring terminals
1.
G
F
E
D
A. Neutral wire (white or center wire)
B. Center silver-colored terminal block screw
C. Neutral grounding wire (green with yellow stripes)
D. External ground conductor screw
E. Green or bare wire of power supply cord
F Internal ground conductor location
G. 3/4" (1.9 cm) UL listed, strain relief
5.
Remove center terminal block screw.
6.
7.
Connect the other wires to outer terminal block screws.
Tighten screws.
Tighten strain relief screws.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
Move the green painted screw from the internal to the external
ground location. Connect ground wire (green or bare) of power
supply cable to external ground conductor screw. Tighten
screw.
4-wire connection: Direct Wire
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
Place the hooked end of the neutral wire _white or center wire)
of power supply cable under the center screw of terminal
block (hook facing right). Squeeze hooked end together.
Tighten screw.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 5" (12.7 cm) of outer covering from end of cable, leaving
bare ground wire at 5" (12.7 cm). Cut 11/2'' (3.8 cm) from
3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends of
wires into a hook shape.
B
,/
f
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw. See example
below.
A. Neutral wire (white or center wire)
B. Center silver-colored terminal block screw
C. Neutral grounding wire (green with yellow stripes)
D. External ground conductor screw
E. Green or bare wire of power supply cable
F. Internal ground conductor location
G. _A" (1.9 cm) UL listed, strain relief
1.
Remove center terminal block screw.
2.
Remove appliance ground wire (green with yellow stripes)
from internal ground conductor screw. Fasten it under center,
silver-colored terminal block screw.
Place the hooked ends of the other power supply cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
6.
7.
C
A. Center silver-colored
terminal block screw
B. Neutral grounding wire (green with yellow stripes)
C. Internal ground conductor screw
Tighten strain relief screws.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
3-wire connection:
3-wire connection: Direct Wire
Power supply cord
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
D
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
E
B
C
A.
B.
C.
D.
E.
£
G.
1.
2.
G
F
Strip 31/2'' (8.9 cm) of outer covering from end of cable. Strip
insulation back 1" (2.5 cm). If using 3-wire cable with ground wire,
cut bare wire even with outer covering. Shape ends of wires into a
hook shape.
3-wire receptacle (NEMA type 10-30R)
3-wire plug
Neutral prong
Spade terminals with up turned ends
_" (!.9 cm) UL listed strain relief
Ring terminals
Neutral (white or center wire)
Loosen or remove center terminal block screw.
Connect neutral wire (white or center wire) of power supply
cord to the center, silver-colored terminal screw of the terminal
block. Tighten screw.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw.
o
f
s
1.
2.
Loosen or remove center terminal block screw.
Place the hooked end of the neutral wire (white or center wire)
of power supply cable under the center screw of terminal
block (hook facing right). Squeeze hooked end together.
Tighten screw.
A. Neutral wire (white or center wire)
B. Center silver-colored terminal block screw
C. Neutral grounding wire (green with yellow stripes)
D. Internal ground conductor screw
E.3/4"(1.9 cm) UL listed, strain relief
3.
4.
5.
Connect the other wires to outer terminal block screws.
Tighten screws.
Tighten strain relief screws.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
A. Neutral wire (white or center wire)
B. Center silver-colored terminal block screw
C. Neutral grounding wire (green with yellow stripes)
D. Internal ground conductor screw
E. _/4"(1.9 cm) UL listed, strain relief
3.
Place the hooked ends of the other power supply cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
Fire Hazard
Use a heavy metal vent,
4.
Tighten strain relief screws.
5.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
Do not use a plastic
Do not use a meta_ foi_ vent,
Failure to follow
or fire,
Optional 3-wire connection
Use for direct wire or power supply cord where local codes do
not permit connecting cabinet-ground conductor to neutral
wire.
1. Remove center terminal block screw,
2.
3.
Remove neutral grounding wire (green with yellow stripes)
from internal ground conductor screw. Connect appliance
ground wire and the neutral wire (white or center wire) of
power supply cord/cable under center, silver-colored terminal
block screw. Tighten screw.
Connect the other wires to outer terminal block screws.
Tighten screws,
4.
Tighten strain relief screws.
5.
Move the green painted screw from the internal to the external
ground conductor location. Connect a separate copper
ground wire from the external ground conductor screw to an
adequate ground.
vent,
these instructions
can result in death
WARNING:
To reduce the risk of fire, this washer/dryer
MUST BE EXHAUSTED OUTDOORS.
4" (10,2 cm) heavy metal exhaust vent and clamps must be used.
DURASAFE TM venting products are recommended.
DURASAFE TM vent products can be purchased from your dealer
or by calling Whirlpool Parts and Accessories. For more
information, see the "Assistance or Service" section of your
"Washer/Dryer User Instructions."
•
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, or a concealed space of a building.
•
Do not use an exhaust hood with a magnetic latch.
•
Do not install flexible metal vent in enclosed walls, ceilings or
floors.
•
Use clamps to seal all joints. Exhaust vent must not be
connected or secured with screws or other fastening devices
which extend into the interior of the duct. Do not use duct
tape.
IMPORTANT: Observe all governing codes and ordinances.
_mproper venting can cause moisture
indoors, which may result in:
[]
Moisture damage to woodwork,
wallpaper, carpets, etc=
[]
Housecleaning
and _int to collect
furniture, paint,
problems and health problems.
Use a heavy metal vent. Do not use plastic or metal foil vent.
E
A. Neutral wire (white or center wire)
B. Neutral grounding wire (green with yellow stripes)
C. External ground conductor screw
D. Grounding path determined by a qualified electrician
E. Internal ground conductor location
6=
10
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
Rigid metal vent is recommended to prevent crushing and kinking.
Flexible metal vent must be fully extended and supported when
the washer/dryer is in its final position. Remove excess flexible
metal vent to avoid sagging and kinking that may result in reduced
airflow and poor performance.
An exhaust hood should cap the vent to prevent rodents and
insects from entering the home.
Exhaust hood must be at least 12" (30.5 cm) from the ground or
any object that may be in the path of the exhaust (such as flowers,
rocks or bushes, etc.).
If using an existing vent system, clean lint from the entire length of
the system and make sure exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid metal or flexible
metal vent.
',
Excessive Weight Hazard
Use two or more people to move and install
washer/dryer.
Failure to do so can result in back or other injury.
,:t
Proper connection of the drain hose protects your floors from
damage due to water leakage. To prevent the drain hose from
coming off or leaking, it must be installed according to the
following instructions:
IMPORTANT: To ensure proper installation, this procedure must
be followed exactly.
1. Check the drain hose to see whether it is the proper length.
2.
Wet the inside of the straight end of the drain hose with tap
water.
IMPORTANT: Do not use any lubricant other than water.
To protect the floor, use a large flat piece of cardboard from the
shipping carton. Gently place the washer/dryer on its side, on the
cardboard.
3.
Squeeze ears of the silver, double-wire clamp with pliers to
open. Place clamp over the straight end of the drain hose
1A" (6.4 mm) from the end.
4.
Open clamp. Twist hose back and forth while pushing onto
drain connector on the side of the washer/dryer. Continue until
hose contacts the ribbed stops on the cabinet.
Install the rear leveling legs
1. Push legs into holes in rear corners until they snap into place.
2.
Check adjustability of rear legs by pushing in one leg. The
other leg should come out. Check both legs. If they do not
move freely, repeat Step 1.
Install the front leveling legs
1. Examine the front leveling legs. Find the diamond marking.
2. Screw front legs by hand, into the holes in the triangular
braces in the front corners. Use wrench to finish turning the
legs until the diamond marking is no longer visible.
\
\
5.
3.
Slowly stand the washer/dryer
1.
Open the washer lid. The latch under the dryer will keep the lid
open.
Pull the foam packing ring out of the washer.
2.
upright.
\
\
\
Place clamp over the area marked "CLAMR" Release clamp.
For laundry tub or standpipe drain systems
1. Open the yellow, single-wire clamp and slide over the hooked
end of the drain hose to secure the rubber and corrugated
sections together.
A. Hooked end
B. Drain hose
NOTE: Keep the foam ring and use it when transporting your
washer/dryer. This packing material is used to keep the washer
tub stable during transport.
11
2=
Put the hooked end of drain hose into laundry tub or
standpipe. Rotate hook to eliminate kinks.
To prevent
NOTE: Do not overtighten. Damage to the valves can result.
drain water from going back into the washer:
•
Do not straighten hooked end of the drain hose and force
excess drain hose into standpipe. Hose should be secure
but loose enough to provide a gap for air.
•
Do not lay excess hose on the bottom of the laundry tub.
For use with floor drain
Remove the drain hose hook from the corrugated drain hose. You
may need additional parts. See "Floor drain" under "Alternate
Parts."
S
A. Cold water inlet valve (blue)
B. Hot water inlet valve (red)
1.
Insert a new flat washer (supplied) into each end of the inlet
hoses. Firmly seat the washers in the couplings.
7.
Attach the hose with the red coupling to the hot water
(bottom) inlet valve. Screw on coupling by hand until it is
seated on the washer. Using pliers, tighten the couplings with
an additional two-thirds turn.
NOTE: Do not overtighten. Damage to the valves can result.
A
A. Coupling
B. Washer
Connect
the inlet hoses to the water faucets
Make sure the washer basket is empty.
2. Attach the hose with the red coupling to the hot water faucet.
Screw on coupling by hand until it is seated on the washer.
3. Attach the hose with the blue coupling to the cold water
faucet. Screw on coupling by hand until it is seated on the
washer.
4.
If you are working in a closet or recessed area
Move the washer/dryer into its final position and remove
cardboard from under washer/dryer. Remove the access panel by
removing three Phillips-head screws and one bumper, located at
the top of the access panel. Set panel, screw, and bumper aside.
Complete hookup of water hoses and (on gas models) the flexible
gas connector through the access area. Replace access panel
upon completion of washer/dryer installation.
Using pliers, tighten the couplings with an additional twothirds turn.
Check for leaks
8. Turn on the water faucets and check for leaks. A small amount
of water might enter the washer. You will drain this later.
NOTE: Replace inlet hoses after 5 years of use to reduce the risk
of hose failure. Record hose installation or replacement dates for
future reference.
NOTE: Do not overtighten.
Damage to the valves can result.
•
If you connect only one water hose, you must cap off the
remaining water inlet port.
•
Periodically inspect and replace hoses if bulges, kinks, cuts,
wear, or leaks are found.
Clear the water lines
5.
Run water through both faucets and inlet hoses, into a bucket
or laundry tub, to get rid of particles in the water lines that
might clog the inlet valve screens.
Connect
6.
12
the inlet hoses to the washer
Attach the hose with the blue coupling to the cold water (top)
inlet valve. Screw on coupling by hand until it is seated on the
washer. Using pliers, tighten the couplings with an additional
two-thirds turn.
1.
2.
Move the washer/dryer to its final location and remove any
cardboard used to move the washer/dryer.
Locate the plastic strap included in the parts package.
(2Z>
692790 (white)
3977784 (biscuit)
Follow the instructions in the kit to install. Kits are available from
the dealer from whom you purchased your washer/dryer.
Beaded tie strap
3.
Optional exhaust installations
This washer/dryer can be converted to exhaust out the right or left
side. To convert the washer/dryer, use Side Exhaust Kit
Part Number 279823. If your washer/dryer was previously
exhausted from the right or left side, it can be converted to rear
exhaust by using standard offset connections. To cover the hole in
the side, one of the following plugs can be added:
Wrap the drain hose to the laundry tub leg or standpipe with
the plastic strap (A or B below) and secure.
i
T¸
J i
L
C
If the water faucets and the drain standpipe are recessed, put
the hooked end of the drain hose in the standpipe. Tightly
wrap the plastic strap around the water inlet hoses and the
drain hose (C above).
B
A. Standard rear offset exhaust installation
B. Rear exhaust for offset close clearance connection
C. Left or right side exhaust installation
Alternate
Typical exhaust installations
Typical installations vent the dryer from rear of the washer/dryer.
Other installations are possible.
C
installations
for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Three close-clearance installations are shown.
Refer to the manufacturer's instructions provided with the vent
system.
t ......
......
i
/
B
,,
,...................................E
"\i
.................
G
C .......
A. Dryer
B. Rigid metal or
flexible metal vent
C. Clamps
D. Wall
H
E.
F.
G.
H.
Elbow
Clamps
Elbow
Exhaust hood
A
.........
"\
B
!
C
A. Loop system with standard elbows
B. Loop system with one offset & one standard elbow
C. Vent system with one periscope (2" [5 cm] clearance)
NOTE: The following kits for close clearance alternate installations
are available for purchase. Please reference the "Assistance or
Service" section of your "Washer/Dryer User Instructions."
•
Over thetop Installation:
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0" (0 cm) to 18" (45.72 cm) mismatch
Part Number 4396011 - 18" (45.72 cm) to 29" (73.66 cm)
mismatch
Part Number 4396014 - 29" (73.66 cm) to 50" (127 cm)
mismatch
13
The angled hood style (shown following) is acceptable.
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
See the exhaust vent length chart that matches your hood
type for the maximum vent lengths you can use.
Exhaust systems longer than specified will:
3.
•
Shorten the life of the dryer.
•
Reduce performance, resulting in longer drying times and
increased energy usage.
Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than those
specified in the Vent Length Chart.
Determine vent length
1. Select the route that will provide the straightest and most
direct path outdoors. Plan the installation to use the fewest
number of elbows and turns. When using elbows or making
turns, allow as much room as possible. Bend vent gradually to
avoid kinking. Avoid 90 ° turns when possible.
2.
The following chart helps you determine your maximum vent
length based on the number of 90 ° turns or elbows you will
need and the type of vent (rigid metal or flexible metal) and
hood that you will use.
Vent Length Chart
Number of
90 ° turns
or elbows
Type of Vent
Box or
Louvered
hoods
Angled
hoods
0
Rigid metal
43 ft (13.1 m)
36 ft (11.0 m)
Flexible metal
30 ft (9.1 m)
24 ft (7.3 m)
Determine vent length.
The maximum length of the exhaust system depends upon:
1
Rigid metal
Flexible metal
33 ft (10.1 m)
24 ft (7.3 m)
26 ft (7.9 m)
18 ft (5.5 m)
•
The type of vent (rigid metal or flexible metal).
2
•
The number of elbows used.
Rigid metal
Flexible metal
24 ft (7.3 m)
16 ft (4.9 m)
16 ft (4.9 m)
10 ft (3.0 m)
• Type of hood.
Recommended hood styles are shown here.
B
NOTE: Side exhaust adds a 90 ° turn inside the washer/dryer. To
determine maximum exhaust length, add one 90 ° turn to the
chart.
1.
2.
1"_4,,4b-=
(10.2
C_}
A. Louvered hood style
B. Box hood style
14
3.
Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
Run vent to dryer location. Use the straightest path possible.
See "Determine vent length." Avoid 90 ° turns. Use clamps to
seal all joints. Do not use duct tape, screws or other fastening
devices that extend into the interior of the vent to secure vent.
Properly leveling your washer/dryer
vibration.
1.
2.
prevents excessive noise and
1.
Check the levelness of the washer/dryer by placing a level on
the top edge of the washer, first side to side, then front to
back.
Check to be sure all parts are now installed. If there is an extra
part, go back through the steps to see which step was
skipped.
2.
3.
Check to be sure you have all of your tools.
Dispose of/recycle all packaging materials. Keep the plastic
foam for use if the washer/dryer should be transported.
4.
Check the washer/dryer's
crushed or kinked.
5.
6.
7.
Check to be sure the washer/dryer is level and front leveling
feet are tight. See "Level Washer/Dryer."
Plug into a grounded outlet. Turn on power.
Check to be sure the water faucets are on.
8.
Check for leaks around faucets and inlet hoses.
9.
Remove the blue protective film on the console and any tape
remaining on the washer/dryer.
Read your "Washer/Dryer User Instructions."
Wipe the dryer drum interior thoroughly with a damp cloth to
remove any dust.
To test the washer, measure 1/2the normal recommended
amount of detergent and pour it into the washer. Close the lid.
Select HEAVY DUTY and pull out the Cycle Control knob.
Allow the washer to complete one whole cycle.
To test the dryer, set the dryer on a full heat cycle (not an air
cycle) for 20 minutes and start the dryer.
If the dryer will not start, check the following:
If the washer/dryer is not level, prop up the front with a wood
block and adjust the feet up or down as necessary. Remove
wood block and lower washer/dryer. Repeat this step until the
washer/dryer is level.
10.
11.
12.
1.
2.
3.
Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in
washer/dryer. If connecting to existing vent, make sure the
vent is clean. The vent must fit over the exhaust outlet and
inside the exhaust hood. Make sure the vent is secured to
exhaust hood with a 4" (10.2 cm) clamp.
Move washer/dryer into final position. Do not crush or kink
vent. Make sure washer/dryer is level.
(On gas models) Check to be sure there are no kinks in the
flexible gas line.
13.
final location. Be sure the vent is not
•
Controls are set in a running or "On" position.
•
Start button has been firmly pushed.
•
Washer/dryer is plugged into a grounded outlet.
•
Electrical supply is connected.
•
House fuse is intact and tight, or circuit breaker has not
tripped.
•
Dryer door is closed.
14. When the dryer has been running for 5 minutes, open the
dryer door and feel for heat.
If you do not feel heat, turn off the dryer and check the
following:
•
There may be 2 fuses or circuit breakers for the dryer.
Check to make sure both fuses are intact and tight, or that
both circuit breakers have not tripped. If there is still no
heat, contact a qualified technician.
NOTE: You may notice a burning odor when dryer is first heated.
This odor is common when the heating element is first used. The
odor will go away.
15
8542748A
©) 2004.
All rights reserved.
Benton Harbor, Michigan 49022
TM DURASAFE is a trademark of Whirlpool,
U.S.A.
10/04
Printed in U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 16 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Fri Apr 20 15:46:40 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools