White Rodgers 1F81 51 Users Manual (37 5854C)
1F97W-71 0037-5854
1f81-51 to the manual f4d7b2ab-7391-4cea-bc49-3e3feeea2a19
2015-01-05
: White-Rodgers White-Rodgers-1F81-51-Users-Manual-162525 white-rodgers-1f81-51-users-manual-162525 white-rodgers pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
1F81-51 Programmable Electronic Digital Multi-stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS WHITE-RODGERS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION Your new White-Rodgers 5-Day/2-Day Digital Multi-stage Thermostat uses the technology of a solid-state microcomputer to provide precise time/temperature control. This thermostat offers you the flexibility to design heating and cooling programs that fit your needs. Features: • Separate 5-day (weekday) and 2-day (weekend) programming with four separate time/temperature periods per program • Simultaneous heat and cool program storage • Optional C terminal (dual power option) • Preprogrammed temperature control • LCD continuously displays set point, and alternately displays time and room temperature • Temperature override until next program period • Manual program override (HOLD temperature) • °F/°C convertibility • Temperature range 45° to 90°F • Two-stage heat/two-stage cool • Armchair Programming Capability PRECAUTIONS This thermostat is intended for use with a 24-volt system; do not use this thermostat with a millivolt or line voltage system. If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or electrician. ! CAUTION To prevent electrical shock and/or equipment damage disconnect electric power to system at main fuse or circuit breaker box until installation is complete. Do not exceed the specification ratings. All wiring must conform to local and national electrical codes and ordinances. This control is a precision instrument, and should be handled carefully. Rough handling or distorting components could cause the control to malfunction. ! WARNING Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard. Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage. SPECIFICATIONS ELECTRICAL DATA Electrical Rating: 20 to 30 VAC 50/60 Hz. or D.C. 0.05 to 1.5 Amps (Load per terminal) 1.5 Amps Maximum Total Load (All terminals combined) THERMAL DATA Setpoint Temperature Range: 45°F to 90°F (7°C to 32°C) Operating Ambient Temperature Range: 32°F to 105°F Operating Humidity Range: 0 to 90% RH (non-condensing) Shipping Temperature Range: -40°F to 150°F WHITE-RODGERS DIVISION EMERSON ELECTRIC CO. 9797 REAVIS ROAD ST. LOUIS, MISSOURI 63123-5398 APPLICATIONS For use with: • Heat/cool systems with up to two stages heat, two stages cool DO NOT USE WITH: • Millivolt systems • Systems exceeding 30 VAC and 2.5 amps • 3-wire zoned hydronic heating systems Printed in U.S.A. PART NO. 37-5854E Replaces 37-5854D 0004 INSTALLATION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermostat and the wall mounting plate as an assembly. 3. Identify each wire attached to the old thermostat using the labels enclosed with the new thermostat. 4. Disconnect the wires from old thermostat one at a time. DO NOT LET WIRES FALL BACK INTO THE WALL. 5. Install new thermostat using the following procedures. W901 CUT FOR LONGER CYCLES W903 CUT TO DEFEAT EMR GAS ELECTRIC PRE-INSTALLATION SET-UP 1. Remove the packing material from the thermostat. 2. This thermostat is configured from the factory to operate a heat/cool, fossil fuel (gas, oil, etc.), forced air system with up to 2 stages of heat and 2 stages of cool. It is configured correctly for any system that DOES NOT require the thermostat to energize the fan on a call for heat. If your system is an electric heat or heat-pump system that REQUIRES the thermostat to turn on the fan on a call for heat, locate the GAS/ELECTRIC switch on the back of the thermostat (see fig. 1) and switch it to the ELECTRIC position. This will allow the thermostat to energize the fan immediately on a call for heat. If you are unsure if the heating/ cooling system requires the thermostat to control the fan, contact a qualified heating and air conditioning service person. 3. Two jumpers are also located on the back of the thermostat, so that you may customize the thermostat to meet your individual preference (see fig. 1). In most applications, the factory jumper settings provide the most comfortable and convenient thermostat operation. Jumper wire W901 determines how fast the system cycles on and off, based on temperature change. As shipped from the factory, the thermostat will maintain a very consistent room temperature, usually within 1°F of the thermostat setting. To achieve a slower on and off cycle, providing a slightly wider temperature span, cut and separate jumper wire W901. Jumper wire W903 controls the Energy Management Recovery (EMR) feature. EMR allows the thermostat to energize the heating system up to 30 minutes before the time programmed into the thermostat. The thermostat will then energize the system to gradually raise the temperature to your programmed temperature by using the most efficient stage of heat practical. For example, assume that the thermostat is programmed overnight to 66°F and the room temperature is 66°. If the next program is 7 AM, 70°F (an increase of 4°), the thermostat will start the system 30 minutes before 7 AM. If the temperature is in the room is within 2°F of your next programmed temperature, the thermostat will not start the system early. DO NOT clip jumper wire W903 unless you wish to permanently disable the EMR feature. If LOW BATTERY is displayed, the batteries are low and should be replaced with fresh “AA” Energizer® alkaline batteries. To replace batteries, install the batteries along the top of the base (see fig. 2). The batteries must be installed with the positive (+) ends to the left. 2 Figure 1. Back of thermostat base Alkaline batteries (3 “AA”– install “+” ends to the left) Screw anchors C W2 G Reset button W Y2 R Y Mounting holes Figure 2. Thermostat base INSTALLING THE THERMOSTAT 1. Gently remove the cover by pulling it straight off the base. Forcing or prying on the unit may cause damage to the unit. 2. Remove the battery tab. With the batteries installed, the Armchair Programming feature allows you to program the thermostat before installing it on the wall. 3. Pull wires through the hole in the thermostat base and place the base over the hole in the wall. Mark mounting hole locations on the wall using the base as a template. 4. Move the base out of the way. Drill mounting holes. 5. Fasten the base loosely to the wall, as shown in fig. 2, using two mounting screws. Place a level against the bottom of the base, adjust until level, and then tighten the screws. (Leveling is for appearance only and will not affect thermostat operation.) If you are using existing mounting holes, or if the holes drilled are too large and do not allow you to tighten the base snugly, use plastic screw anchors to secure the base. 6. Check that the SYSTEM switch is in the OFF position. Connect the wires beneath the terminal screws on the base using the appropriate wiring diagram (see figs. 3 through 5). 7. Push excess wire into wall and plug hole with a fire-resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation. (Instructions continue on page 4.) NOTE NOTE The following wiring diagrams show typical terminal identification and wiring. For proper installation, refer to the original manufacturer's instructions. Relay contacts shown are thermostatically operated. * The 24 Volt neutral connection to terminal C on the thermostat is not required if you replace the batteries once a year with fresh “AA” Energizer® alkaline batteries. Thermostat Control Circuit THERMOSTAT Y Y2 G W2 W C* R SYSTEM Heat Relay Stage 1 Compressor Contactor Stage 2 Hot 24 VAC Compressor Contactor Stage 1 Heat Relay Stage 2 Fan Relay 120 VAC Neutral TRANSFORMER Figure 3. Typical wiring diagram for single transformer systems * The 24 Volt neutral connection to terminal C on the thermostat is not required if you replace the batteries once a year with fresh “AA” Energizer® alkaline batteries. Thermostat Control Circuit THERMOSTAT CUT AND TAPE OFF! Y G W2 W C* R SYSTEM Hot 120 VAC Y2 24 VAC Neutral Heat Relay Stage 1 Compressor Contactor Stage 2 Hot 24 VAC TRANSFORMER Compressor Contactor Stage 1 Heat Relay Stage 2 Fan Relay 120 VAC Neutral TRANSFORMER TWO COMMONS MUST BE JUMPERED TOGETHER! Figure 4. Typical wiring diagram for two-transformer systems with NO safety circuits * The 24 Volt neutral connection to terminal C on the thermostat is not required if you replace the batteries once a year with fresh “AA” Energizer® alkaline batteries. Thermostat Control Circuit THERMOSTAT Y Y2 G W W2 C* R SYSTEM Heat Relay Stage 1 Compressor Contactor Stage 2 Compressor Contactor Stage 1 Fan Relay Limit or Safety Switches 24 VAC 120 VAC Limit or Safety Hot Switches Neutral Heat Relay Stage 2 24 VAC Accessory Relay N.O. Contact HEATING TRANSFORMER Common TWO COMMONS MUST BE JUMPERED TOGETHER! Limit or Safety Switches Common 24 VAC 120 VAC Limit or Safety Hot Switches Neutral COOLING TRANSFORMER Figure 5. Typical wiring diagram for two-transformer systems with safety circuits in BOTH systems 3 CHECK THERMOSTAT OPERATION NOTE If at any time during testing, your system does not operate properly, contact a qualified serviceperson. If the fan is running but the compressor is not running and the word COOL is flashing, the compressor lockout feature is operating (see Lockout Bypass Option to temporarily override the compressor lockout feature during testing). 3. Press to adjust temperature setting above room tempera- ture. The cooling system should stop operating. Fan Operation 1. 2. 3. 4. Turn on power to the system. Move SYSTEM switch to OFF position. Move FAN switch to ON. The blower should begin to operate. Move FAN switch to AUTO position. The blower should stop within a short period of time. Heating System 1. Move SYSTEM switch to HEAT position 2. Press to adjust temperature setting below room tempera- ture. The auxiliary heating system will stop immediately and the first stage will stop within three to four minutes. Cooling System ! CAUTION To prevent compressor and/or property damage, if the outdoor temperature is below 50°F, DO NOT operate the cooling system. 1. Move SYSTEM switch to COOL position. 2. Press to adjust thermostat setting to 45° and hold for five seconds. The blower should come on immediately on high speed, followed by cold air circulation. Both stages of the cooling system should begin to operate (if you have a twostage cooling system). 4 During normal operation, the second stage of heat or cool may take 15 to 30 minutes to turn on. The delay varies depending on the performance of the first stage. Typically the second stage will come on sooner in more severe weather, while in milder weather it will take longer. There is no adjustment to this feature, as it is designed to maximize both comfort and efficiency. LOCKOUT BYPASS OPTION to adjust thermostat setting to 90° and hold for five seconds. Both stages of the heating system should begin to operate within five seconds. 3. Press NOTE FOR QUALIFIED SERVICE TECHNICIANS’ USE ONLY. OPERATORS SHOULD NOT USE THIS FEATURE DUE TO POSSIBILITY OF EQUIPMENT OR PROPERTY DAMAGE, OR PERSONAL INJURY. COMPRESSOR SHORT TERM CYCLE PROTECTION During normal operation, this thermostat has a builtin short term (5-minute) time delay. During this 5minute period, the thermostat will lock out the compressor to allow head pressure to stabilize. If you want to override this feature while testing thermostat operation, simply press and buttons at the same time. DO NOT USE THE LOCKOUT BYPASS OPTION UNLESS THE COMPRESSOR OIL HEATERS HAVE BEEN OPERATIONAL FOR 6 HOURS AND THE SYSTEM HAS NOT BEEN OPERATIONAL FOR AT LEAST 5 MINUTES. OPERATION Before you begin programming your thermostat, you should be familiar with its features and with the display and the location and operation of the thermostat buttons. Your thermostat consists of two parts: the thermostat cover and the base. To remove the cover, gently pull it straight out from the base. To replace the cover, line up the cover with the base and press gently until the cover snaps onto the base. 2 1 THE THERMOSTAT BASE SET TIME VIEW PRGM RUN PRGM HOLD TEMP Other than and AUTO FAN ON , the following buttons and switches are SYSTEM COOL-OFF-HEAT located behind the door on the bottom of the thermostat cover (see fig. 6). Pull the door down to open it. The Thermostat Buttons and Switches 3 1 (Red arrow) Raises temperature setting. 4 9 2 (Blue arrow) Lowers temperature setting. 11 6 7 10 MO TU WE TH FR 3 SET TIME button. 5 8 9 SA SU HEAT 1+2 AM HOLD COOL 1+2 4 VIEW PRGM (program) button. 12 5 RUN PRGM (program) button. 11 13 10 Figure 6. Thermostat display, buttons, and switches 6 HOLD TEMPerature button. • HOLD TEMPERATURE — The thermostat can hold any temperature within its range for an indefinite period, without reverting to the programmed temperature. Press HOLD TEMP button. HOLD will be displayed. Then choose the 7 FAN switch (ON, AUTO). 8 SYSTEM switch (COOL, OFF, HEAT). The Display desired hold temperature by pressing 9 Indicates day of the week. 10 HEAT is displayed when the SYSTEM switch is in the HEAT position. COOL is displayed when the SYSTEM switch is in the COOL position. COOL is displayed (flashing) when the compressor is in lockout mode. 11 Alternately displays current time and room temperature. 12 Displays currently programmed set temperature (this is blank when SYSTEM switch is in the OFF position). 13 The word HOLD is displayed when the thermostat is in the HOLD mode. Now that you are familiar with the thermostat buttons and display, read the following information to learn about the many features of the thermostat. • SIMULTANEOUS HEATING/COOLING PROGRAM STORAGE — When programming, you can enter both your heating and cooling programs at the same time. There is no need to reprogram the thermostat at the beginning of each season. • TEMPERATURE OVERRIDE — Press or until the display shows the temperature you want. The thermostat will override current programming and keep the room temperature at the selected temperature until the next program period begins. Then the thermostat will automatically revert to the program. . The ther- mostat will hold the room temperature at the selected setting until you press RUN PRGM button to start program operation again. • °F/°C CONVERTIBILITY — Press SET TIME and HOLD TEMP buttons until the temperature display is in Celsius (°C). To display Fahrenheit (°F), repeat the process. • TEMPERATURE DISPLAY ADJUSTMENT — Your new thermostat has been accurately set in our factory. However, if you wish, you may adjust your new thermostat temperature display to match your old thermostat. This can be accomplished (within a ±4°F range) as follows: 1. Press VIEW PRGM and HOLD TEMP buttons at the same time. 2. Press OPERATING FEATURES or or to adjust the displayed temperature to your desired setting. 3. Press RUN PRGM to resume normal program operation. PROGRAMMING YOUR THERMOSTAT Now you are ready to program your thermostat. This section will help you plan your thermostat’s program to meet your needs. For maximum comfort and efficiency, keep the following guidelines in mind when planning your program. • When heating (cooling) your building, program the temperatures to be cooler (warmer) when the building is vacant or during periods of low activity. • During early morning hours, the need for cooling is usually minimal. (Instructions continue on page 6.) 5 Look at the factory preprogrammed times and temperatures shown below. If this program will suit your needs, simply press the RUN PRGM button to begin running the factory preset program. FACTORY PREPROGRAMMING Cooling Program for Heating Program for ALL Days of the Week: ALL days of the Week: PERIOD 1st 2nd 3rd 4th TIME 6:00 AM 8:00 AM 5:00 PM 10:00 PM TEMP 70°F 62°F 70°F 62°F PERIOD 1st 2nd 3rd 4th TIME 6:00 AM 8:00 AM 5:00 PM 10:00 PM TEMP 78°F 85°F 78°F 82°F If you want to change the preprogrammed times and temperatures, follow these steps. Determine the time periods and heating and cooling temperatures for your weekday and weekend programs. You must program four periods for both the weekday and weekend program. However, you may use the same heating and cooling temperatures for consecutive time periods. You can choose start times, heating temperatures, and cooling temperatures independently for both weekday and weekend programs (for example, you may select 5:00 AM and 70° as the weekday 1st period heating start time and temperature, and also choose 7:00 AM and 76° as the weekday 1st period cooling start time and temperature). Use the table at the bottom of the page to plan your program time periods, and the temperatures you want during each period. You may also want to look at the sample program table to get an idea of how the thermostat can be programmed. 3. Press SET TIME once. The display window will show the minutes only. EXAMPLE: 4. Press and hold either or until you reach the correct minutes. 5. Press SET TIME once. The display will show the day of the week. 6. Press or until you reach the current day of the week. 7. Press RUN PRGM once. The display will show the correct time and room temperature alternately. Enter Heating Program 1. If you want to change the display from Fahrenheit to Celsius (or vice-versa), press SET TIME and HOLD TEMP at the same time. 2. Move the SYSTEM switch to HEAT. 3. Press VIEW PRGM once. “MO TU WE TH FR” (indicating weekday program) will be displayed. Also displayed are the currently programmed start time for the 1st heating period and the currently programmed temperature (flashing). MO TU WE TH FR AM EXAMPLE: Entering Your Program Follow these steps to enter the heating and cooling programs you have selected. This display window shows that for the 1st weekday period, the start time is 6:00 AM, and 70° is the programmed temperature (this example reflects factory preprogramming). Set Current Time and Day 4. Press 1. Press SET TIME button once. The display will show the hour only. selected temperature for the 1st heating program period. 5. Press SET TIME once (the programmed time will flash). Press EXAMPLE: PM 2. Press and hold either or until you reach the correct hour and AM/PM designation (AM begins at midnight; PM begins at noon). or or until your selected time is displayed. The time will change in 15 minute increments. When your selected time is displayed, press SET TIME again to return to the change temperature mode. 6. Press VIEW PRGM once. The currently programmed start time and setpoint temperature for the 2nd heating program period will be displayed. SAMPLE Heating/Cooling Schedule Plan WEEKEND (2 DAY) WEEKDAY (5 DAY) Heating/Cooling Schedule Plan WEEKEND (2 DAY) WEEKDAY (5 DAY) Period Start Time Temperature Start Time Temperature 1ST HEAT 1ST HEAT 5:30 AM 70°F 7:00 AM 70°F 2ND HEAT 2ND HEAT 8:00 AM 65°F 11:00 AM 70°F 3RD HEAT 3RD HEAT 5:00 PM 70°F 6:00 PM 70°F 4TH HEAT 4TH HEAT 10:30 PM 65°F 11:30 PM 65°F 1ST COOL 1ST COOL 6:30 AM 76°F 7:00 AM 76°F 2ND COOL 2ND COOL 2:00 PM 78°F 12:30 PM 74°F 3RD COOL 3RD COOL 5:00 PM 72°F 6:00 PM 72°F 4TH COOL 4TH COOL 10:30 PM 78°F 11:30 PM 78°F Period 6 to change the displayed temperature to your Start Time Temperature Start Time Temperature 7. Repeat steps 4 and 5 to select the start time and heating temperature for the 2nd heating program period. 8. Repeat steps 4 through 6 for the 3rd and 4th heating program periods. Weekday heating programs are now complete. 9. Press VIEW PRGM once. “SA SU” (indicating weekend program) will be displayed, along with the start time for the 1st heating period and the currently programmed temperature. 10. Repeat steps 4 through 8 to complete weekend heating programming. 11. When you have completed entering your heating program, press RUN PRGM. Enter Cooling Program ! CAUTION CHECK YOUR PROGRAMMING Follow these steps to check your thermostat programming one final time before beginning thermostat operation. 1. Move SYSTEM switch to HEAT position. 2. Press VIEW PRGM to view the 1st weekday heating period time and temperature. Each time you press VIEW PRGM, the next heating period time and temperature will be displayed in sequence for weekday, then weekend program periods (you may change any time or temperature during this procedure). 3. Press RUN PRGM. 4. Move SYSTEM switch to COOL position. 5. Repeat step 2 to check cooling temperatures. 6. Press RUN PRGM to begin program operation. If the outside temperature is below 50°F, disconnect power to the cooling system before programming. Energizing the air conditioner compressor during cold weather may cause personal injury or property damage. YOUR THERMOSTAT IS NOW COMPLETELY PROGRAMMED AND READY TO AUTOMATICALLY PROVIDE MAXIMUM COMFORT AND EFFICIENCY! 1. Move SYSTEM switch to COOL position. 2. Follow the procedure for entering your heating program, using your selected cooling times and temperatures. If your thermostat’s display is frozen, blank or displaying incorrectly, the thermostat may have been affected by static discharge or voltage variations. If this happens, press the RESET button (see fig. 2, page 2 for the location of the button). Pressing the RESET button will clear all user programming. The thermostat will revert to factory preprogramming. You will need to reset the time and, if desired, reprogram the thermostat to your selected program. If pressing the RESET button does not correct the problem, contact a qualified service technician. TROUBLESHOOTING For optimum performance, we recommend replacing batteries once a year with fresh “AA” Energizer® alkaline batteries. 7
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.1 Linearized : No Page Count : 8 Create Date : 2000:09:19 12:16:01 Producer : Acrobat Distiller 3.01 for Power Macintosh Subject : 1F81-51 (37-5854C) Creator : Adobe PageMaker 6.52 Title : 1F81-51 (37-5854C) Author : Tom SaitoEXIF Metadata provided by EXIF.tools