Wistron NeWeb CB1GA21LG Integrate with certified module-End product User Manual 1

Wistron NeWeb Corporation Integrate with certified module-End product 1

User manual

   Subject: UMC-A21LG User Manual                                                          REV: 1.0                                                                                        PAGE 1 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document          UMC-A21LG User Manual                    The document contains proprietary information which is the property of Wistron NeWeb Corporation and is strictly confidential and shall not be disclosed to others in whole or in part, reproduced, copied, or used as basic for design, manufacturing or sale of apparatus without the written permission of Wistron NeWeb Corporation.
   Subject: UMC-A21LG User Manual                                                          REV: 1.0                                                                                        PAGE 2 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document Revision History Issue Date  Version  Description 2017/06/29 1.0  Initial Issued
   Subject: UMC-A21LG User Manual                                                          REV: 1.0                                                                                        PAGE 3 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document Contents 1. Introduction .......................................................................................................................................... 4 2. Test Setup Configuration ..................................................................................................................... 5 2.1 Power Supply and Debug Console Connection ...................................................................... 5 2.2 Antenna Connection .................................................................................................................  7 2.3 Hardware Component Introduction ....................................................................................... 8 3. Zigbee Test ............................................................................................................................................ 9 3.1 Install GDM7243 Driver ...........................................................................................................  9 3.2 Confirm the GDM7243 device ................................................................................................. 9 3.3 Open the com port by PuTTy .................................................................................................  10 3.4 Zigbee Test Command .............................................................................................................11 4. LTE B4/B13 Test ................................................................................................................................. 12
   Subject: UMC-A21LG User Manual                                                          REV: 1.0                                                                                        PAGE 4 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 1.    Introduction This User Manual of Victor CB (Communication Board) module is to describe how to use the following sections for lab test by specific qualified engineers or technicians. Furthermore, this module is NOT intended for commercial use but designed as part of Smart Meter product which mainly provides 4G LTE WAN access and/or Zigbee HAN access capabilities. For the procedure of CB installation into electric meter and the operation of CB in assembly factory, that information is described in assembly instruction document.     FCC Interference Statement This module complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This module may not cause harmful interference and (2) this module must accept any interference received, including interference that may cause undesired operation.  Radiation Exposure Statement This module complies with FCC radiation exposure limits set forth for an uncontrolled environment. This module should be installed and operated with minimum distance of 20cm between radiator and human body.  Any changes or modifications not expressly approved by the party responsible for ĐŽŵƉůŝĂŶĐĞĐŽƵůĚǀŽŝĚƚŚĞƵƐĞƌ͛ƐĂƵƚŚŽƌŝƚLJƚŽŽƉĞƌĂƚĞƚŚĞĚĞǀŝĐĞ͘
   Subject: UMC-A21LG User Manual                                                          REV: 1.0                                                                                        PAGE 5 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 2.    Test Setup Configuration 2.1 Power Supply and Debug Console Connection  10 pin Connect to interface board ŽŶ͛ƚĐĂƌĞůĂƐƚϮƉŝŶ DUT (CB) Interface Board
   Subject: UMC-A21LG User Manual                                                          REV: 1.0                                                                                        PAGE 6 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document  Power on Sequence: I. Connect DUT to interface board II. Attach AC-DC Adaptor & USB Debug Port Cable III. Wait for 20 seconds when system ready (See Note 1) IV. Plug-in Console Port cable   [Caution] Improper power on sequence might lead to system boot-up failure!   AC-DC 5V Adaptor Interface Board   DUT (CB) USB Debug Port Console
   Subject: UMC-A21LG User Manual                                                          REV: 1.0                                                                                        PAGE 7 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 2.2 Antenna Connection     Connect to LTE primary antenna     Connect to LTE diversity antenna    Connect to Zigbee antenna
   Subject: UMC-A21LG User Manual                                                          REV: 1.0                                                                                        PAGE 8 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 2.3 Hardware Component Introduction   AC-DC 5V Adaptor  Interface Board    Victor CB
   Subject: UMC-A21LG User Manual                                                          REV: 1.0                                                                                        PAGE 9 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 3.    Zigbee Test 3.1 Install GDM7243 Driver Install the GDM7243 driver ³GDM7243_windows_acm_drivers_installer_v1.1.0.0.zip´  3.2 Confirm the GDM7243 device  Confirm the com port ³GCT GDM7243 LTE USB Serial Port (COMX)´ in the Device Manager.
   Subject: UMC-A21LG User Manual                                                          REV: 1.0                                                                                        PAGE 10 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 3.3 Open the com port by PuTTy Install PuTTy for connection to DUT, refer to http://www.putty.org/ Serial Line: COMX ; Speed: 115200 ; Connection Type: Serial
   Subject: UMC-A21LG User Manual                                                          REV: 1.0                                                                                        PAGE 11 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 3.4 Zigbee Test Command
   Subject: UMC-A21LG User Manual                                                          REV: 1.0                                                                                        PAGE 12 OF 14  Wistron Neweb Corporation Proprietary & Confidential     Design Document 4.   LTE B4/B13 Test It is suggested to use Anritsu MT8820C for RF conductive tests.setc For LTE radiation tests, the LTE antenna gain lists below. ¾ LTE Main Antenna    Band 13 Peak Gain: 2.0 dBi ~ 2.5 dBi    Band 4 Peak Gain: 4.5 dBi ~ 5.0 dBi   ¾ LTE Diversity Antenna    Band 13 Peak Gain: 2.0 dBi ~ 2.5 dBi    Band 4 Peak Gain: 2.5 dBi ~ 3.0 dBi