Wistron NeWeb D54A1 Connected Cooler Radio USA and North America version User Manual

Wistron NeWeb Corporation Connected Cooler Radio USA and North America version

User manual

                  Quick Start Guide  Connected Cooler Radio
  Table of Contents  1. GETTING STARTED ............................................................................................... 5 1.1 UNPACKING INFORMATION ...................................................................................... 5 1.2 INTRODUCTION ...................................................................................................... 5 2. PORTS AND LED INDICATORS .............................................................................. 6 2.1 PORTS ................................................................................................................. 6 2.2 LED INDICATORS .................................................................................................... 7 3. INSTALLATION ..................................................................................................... 8 4. SPECIFICATIONS ................................................................................................ 10
  Declaration of Conformity Manufacturer:   Name: Wistron NeWeb Corporation  Address: 20 Park Avenue II, Hsinchu Science Park, Hsinchu 308, Taiwan, R.O.C   Radio Equipment:   Model: D54A1 Description: Connected Cooler Radio USA and North America version Radio-related Software Version: D54A1_v00.01 Supplied Accessories and Components: NA We,  Wistron  NeWeb  Corporation,  declare  under  our  sole  responsibility  that  the product  described  above  is  in  conformity  with  the  relevant  Union  harmonization legislations: RE Directive (2014/53/EU), RoHS Directive (2011/65/EU) The  following  harmonized  standards  and/or  other  relevant  standards  have  been applied: 1. Health and Safety (Article 3.1(a) of the RE Directive)  EN 62311:2008  EN 60950-1:2006/A11:2009+A1:2010+A12:2011+A2:2013 2. Electromagnetic compatibility (Article 3.1 (b) of the RE Directive)  Final Draft ETSI EN 301 489-1 V2.1.1,    Draft ETSI EN 301 489-3 V2.1.0  Final Draft ETSI EN 301 489-17 V3.1.1 3. Radio frequency spectrum usage (Article 3.2 of the RE Directive)  ETSI EN 300 328 V2.1.1  Draft ETSI EN 300 440 V2.1.0 4. RoHS Directive (2011/65/EU)  EN 50581:2012
   Signed for and on behalf of: Wistron NeWeb Corporation Place: 20 Park Avenue II, Hsinchu Science Park, Hsinchu 308, Taiwan, R.O.C, Date: January 4, 2017   Name: Brian Lin; function: Technical Manager; signature:
  1. Getting Started 1.1 Unpacking Information  The Connected Cooler Radio (CCR)  Battery notice card        1.2 Introduction The Connected Cooler Radio (CCR) works with sensors installed in coolers to deliver  cooler  information  to  Cloud  servers  for  better  monitoring  and management. The Wi-Fi, AGPS, and 3G/4G (based on the models you select) functions of the CCR enables stable delivery of accurate information collected by analog or digital sensors.          Battery Notice Card
  2. Ports and LED Indicators 2.1 Ports        Port Description    1 Power Power supply connection  2 Self-test button The button for activating the self-test process    3 Sensor port Connects to sensors installed in the cooler    4 Engineering   For engineering uses only    5 ANT Antenna connection       1 2 3 4 5
  2.2 LED Indicators       LED Indication Description    Power Steady green All self-tests passed, and the battery is full.    Blinking green   All self-tests passed, and the battery is charging    Off No power connection  RF Steady red Other failures; for example, SIM card, battery, or Wi-Fi functions  Blinking red Unsuccessful antenna connection  Sensors Steady blue The self-test mode is running.  Blinking blue Detected function failure of the temperature sensor or door-open sensor. Notes: 1) This table is only valid for checking the information after pressing the self-test button. 2) The Power LED (Green) will be on during Operating AC mode. Power RF Sensors
  3. Installation 1. Place the CCR in the specified location (for example wall) and affix the screws.       Screw type M4 2. Attach the antenna to the antenna port of the CCR.    3. Connect the power port to the power supply.          Screw Screw Screw Power connection Antenna
  4. Connect the Sensor port to the sensors.       5. Press  the  Self-test  button.  The  system  begins  testing  the  CCR  and  the sensors attached to the CCR.       6. The system will be ready for use when the Power LED returns to steady green, indicating the system functions normally. Refer to the “LED Indicators” section of this document for details if other LED indications are displayed.        Self-test button Sensors Power LED
  4. Specifications  Specifications    Standards Wi-Fi: IEEE 802.11b/g/n (2.4 GHz)   BLE LTE CAT1: B2/4/5/12; 3G: B2/5   Max. power for each frequency And Antenna Typy Antenna Gain  Mobile     Power class Max. Power (dBm) Antenna peak Gain (dBi) LTE Band(s) LTE B2 3 24 4 LTE B4 3 24.5 4 LTE B5 3 24 1 LTE B12 3 24.5 2 UMTS Band(s) FDD II 3 25 4 FDD V 3 25 1 *Antenna Type *Antenna 3G/4G Fixed External    Antenna-For primary antenna Fixed internal  Antenna-For Diversity antenna
  WLAN WiFi TX 11b/g/n Max Power(dBm) 17.9 Antenna peak Gain (dBi) 1 Antenna type internal PCB antenna   BLE Max Power(dBm) 4 Antenna peak Gain (dBi) 1 Antenna type internal PCB antenna     Regions and countries applicable        Connection interfaces USIM 3FF, VGA for sensor(optional)   Power input 12 V DC/ 1 A (powered by UL Listed power source.) Backup battery: 3.7 V > 900 mAH Li-Ion   Environment Ambient operating temperature: –20 °C to +60 °C  Storage temperature: –40 °C to +70 °C    Dimensions 150 mm (L) × 50 mm (W) ×30 mm (H) (without antenna and screws)
    5. Instruction  Instruction    CAUTION  Only authorized service providers shall replace battery.    Do not disassemble or open crush, bend or deform, puncture or shred  Do not modify or remanufacture, attempt to insert foreign objects into the battery, immerse or expose to water or other liquids, expose to fire, explosion or other hazard.  Only use the battery with a charging system that has been qualified with the system per CTIA Certification Requirements for Battery System Compliance to IEEE 1725. Use of an unqualified battery or charger may present a risk of fire, explosion, leakage, or other hazard.  Replace the battery only with another battery that has been qualified with the system per this standard, IEEE-Std-1725. Use of an unqualified battery may present a risk of fire, explosion, leakage or other hazard.  Promptly dispose of used batteries in accordance with local regulations  Avoid dropping the device or battery. If the device or battery is dropped, especially on a hard surface, and the user suspects damage, take it to a service center for inspection.  Improper battery use may result in a fire, explosion or other hazard. For those host devices that utilize a USB port as a charging source, the host device's user manual shall include a statement that the device shall only be connected to CTIA certified adapters, products that bear the USB-IF logo or products that have
    Specific Absorption Rate information This mobile device meets the government’s requirements for exposure to radio waves. Your mobile device is a radio transmitter and receiver. The exposure standard for mobile devices employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit adopted by Europe is 2.0 W/kg averaged over 10 grams of tissue. Tests for SAR are conducted using standard operating positions with the device transmitting at its highest certified power level in all tested frequency bands. The minimum distance between the user and/or any bystander and the radiating structure of the transmitter is 20cm.
     FCC Regulations: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
   -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.  Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment.   RF Exposure Information This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8 inches) during normal operation.
  ISED Notice This device complies with Innovation, Science and Economic Development Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and   (2) this device must accept any interference, including interference that may cause undesired operation of the device.  Le présent appareil est conforme aux CNR Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:   (1) l'appareil ne doit pas produire de brouillage, et   (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en  This Class B digital apparatus complies with Canadian ICES-003.
  Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.   ISED RF Exposure Statement This device complies with ISED RSS-102 RF exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the ISED RSS-102 RF exposure limits, human proximity to the antenna shall not be less than 20cm (8 inches) during normal operation.  Cet appareil est conforme aux limites d'exposition aux rayonnements de la CNR-102 définies pour un environnement non contrôlé. Afin d'éviter la possibilité de dépasser les limites d'exposition aux fréquences radio de la CNR-102, la proximité humaine à l'antenne ne doit pas être inférieure à 20 cm (8 pouces) pendant le fonctionnement normal.