USERS MANUAL
EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification EM100 Module Module/Data Card integration guide Ver:1.3 2008/01/03 Document Revision History Rev. Draft Check ECO # Date Dec 25st 2007 Brief Description of Change Initial release of Draft Version for Customer Review and Feedback Originator Harry Chen Jun 3 2008 Check and Review Roy Cheng of 27 Approved by EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Notice: Restricted Proprietary Information and subject to the confidentiality restrictions contained in any applicable non-disclosure agreement. The information contained in this document is the exclusive property of Wistron Coporation, Inc. All rights reserved. Unauthorized reproduction of this manual in any form without the expressed written approval of Wistron Wireless, Inc. is strictly prohibited. This manual may not, in whole or in part, be copied, reproduced, translated, or reduced to any electronic or magnetic storage medium without the written consent of a duly authorized officer of Wistron Wireless, Inc. The information contained in this document is subject to change without notice and should not be construed as a commitment by Wistron Wireless, Inc. unless such commitment is expressly given in a covering document. of 27 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Wistron Coporation, Inc. makes no warranties, either expressed or implied, regarding this document, its merchantability, or its fitness, for any particular purpose. Legal Disclaimer This document and the information contained in the EM 100 module& Design Guide (together, the “Information”) is provided to you by Wistron Corporationfor informational purposes only. Wistron Corporationis providing the Information because Wistron Corporation believes the Integration and Design Guidelines may be useful. The Information is provided on the condition that you will be responsible for making your own assessments of the information and are advised to verify all representations, statements and information before using or relying upon any of the Information. Although Wistron Corporationbelieves it has exercised reasonable care in providing the Information, Wistron Corporationdoes not warrant the accuracy of the Information and is not responsible for any damages arising from its use or reliance upon the Information. You further understand and agree that Wistron Corporationin no way represents, and you in no way rely on a belief, that Wistron Corporationis providing the information in accordance with any standard or service (routine, customary or otherwise) related to the consulting, services, hardware or software industries. WISTRON CORPORATIONDOES NOT WARRANT THAT THE INFORMATION IS ERRORFREE. WISTRON CORPORATIONIS PROVIDING THE INFORMATION TO YOU "AS IS" AND "WITH ALL FAULTS." WISTRON CORPORATIONDOES NOT WARRANT, BY VIRTUE OF THIS DOCUMENT, OR BY ANY COURSE OF PERFORMANCE, COURSE OF DEALING, USAGE OF TRADE OR ANY COLLATERAL DOCUMENT HEREUNDER OR OTHERWISE, AND HEREBY EXPRESSLY DISCLAIMS, ANY REPRESENTATION OR WARRANTY OF ANY KIND WITH RESPECT TO THE INFORMATION, INCLUDING, WITHOUT LIMITATION, ANY REPRESENTATION OR WARRANTY OF DESIGN, PERFORMANCE, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, OR ANY REPRESENTATION OR WARRANTY THAT THE INFORMATION IS APPLICABLE TO OR INTEROPERABLE WITH ANY SYSTEM, DATA, HARDWARE OR SOFTWARE OF ANY KIND. WISTRON CORPORATIONDISCLAIMS AND IN NO EVENT SHALL BE LIABLE FOR ANY LOSSES OR DAMAGES OF ANY KIND, WHETHER DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, PUNITIVE, SPECIAL OR EXEMPLARY, INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, LOSS OF GOODWILL, COVER, TORTIOUS CONDUCT OR OTHER PECUNIARY LOSS, ARISING OUT OF OR IN ANY WAY RELATED TO THE PROVISION, NON-PROVISION, USE OR NON-USE OF THE INFORMATION, EVEN IF YOU HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES OR DAMAGES. of 27 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Table of Contents Reference Documents................................................................................................................... 6 EM 100 module................................................................................ 8 3GPP References .......................................................................................................... 8 Safety Warning .............................................................................................................. 11 Federal Communications Commission Notice (FCC—United States) .......................... 13 Radio Frequency Exposure Evaluation Requirements ................................................. 15 Compliance & Certification Requirements .................................................................... 16 Getting Started............................................................................................................................. 17 Feature List ………………………………………………………………………………........17 General.......................................................................................................................... 22 Setting Up...................................................................................................................... 23 of 27 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification of 27 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Reference Documents Phone module EM 100 module Electromehcanical Specification Revision 1.2June 25, 2007 SMBus Specification, Revision 2.0 The I2C-BUS SPECIFICATION Version 2.1 January 2000 3GPP References The following documents contain provisions which, through reference in this text, constitute provisions of the present document. References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. For a specific reference, subsequent revisions do not apply. For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in the same Release as the present document. [1] Void. [2] 3GPP TS 23.038: "Alphabets and language-specific information". [3] 3GPP TS 23.040: "Technical realization of the Short Message Service (SMS) ". [4] 3GPP TS 23.041: "Technical realization of the Cell Broadcast Service (CBS)". [5] 3GPP TS 24.008: "Mobile Radio Interface Layer 3 specification; Core Network Protocols; Stage 3". [6] 3GPP TS 24.011: "Short Message Service (SMS) support on mobile radio interface". [7] 3GPP TS 24.012: "Cell Broadcast Service (CBS) support on the mobile radio interface". [8] 3GPP TS 27.001: "General on Terminal Adaptation Functions (TAF) for Mobile Stations (MS)". [9] 3GPP TS 27.007: "AT command set for User Equipment (UE)". [10] 3GPP TS 51.011: "Specification of the Subscriber Identity Module - Mobile Equipment (SIM - ME) interface". [11] ITU-T Recommendation V.25ter: "Serial asynchronous automatic dialing and control". [12] ITU-T Recommendation V.24: "List of definitions for interchange circuits between data terminal equipment (DTE) and data circuit-terminating equipment (DCE)". of 27 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification [13] ITU-T Recommendation E.164: "The international public telecommunication numbering plan". of 27 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification [14] ITU-T Recommendation E.163: "Numbering plan for the international telephone service". [15] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications". [16] 3GPP TS 31.102: "Characteristics of the USIM application. of 27 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Notices Safety Warning Neither the nor EM 100 MODULE / Data Card products may be used in an environment where radio frequency equipment is prohibited or restricted in its use. This includes aircraft/airports, hospitals, and other sensitive electronic areas. Do not operate RF devices in an environment that may be susceptible to radio interference resulting in danger, specifically: • Areas where prohibited by the law Follow any special rules and regulations and obey all signs and notices. Always turn off the host device when instructed to do so, or when you suspect that it may cause interference or danger. • Where explosive atmospheres may be present Do not operate your modem in any area where a potentially explosive atmosphere may exist. Sparks in such areas could cause an explosion or fire resulting in bodily injury or even death. Be aware and comply with all signs and instructions. • Users are advised not to operate the modem while at a refueling point or service station. Users are reminded to observe restrictions on the use of radio equipment in fuel depots (fuel storage and distribution areas), chemical plants or where blasting operations are in progress. • Areas with a potentially explosive atmosphere are often but not always clearly marked. Potential locations can include gas stations, below deck on boats, chemical transfer or storage facilities, vehicles using liquefied petroleum gas (such as propane or butane), areas where the air contains chemicals or particles, such as grain, dust or metal powders, and any other area where you would normally be advised to turn off your vehicle engine. • Near Medical and life support equipment Do not operate your modem in any area where medical equipment, or life support equipment may be located, or near any equipment that may be susceptible to any form of radio interference. In such areas, the host communications device must be turned off. The modem may transmit signals that could interfere with this equipment. • On an aircraft, either on the ground or airborne In addition to FAA requirements, many airline regulations state that you must suspend Corporationoperations before boarding an airplane. Please ensure that the host device is turned off and your modem is removed from the card slot prior to boarding aircraft in order to comply with these regulations. The modem can transmit signals that could interfere with various onboard systems and controls. • While operating a vehicle of 27 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification The driver or operator of any vehicle should not operate a Corporationdata device. Doing so will detract from the driver or operator's control and operation of that of 27 10 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification vehicle. In some countries, operating such communication devices while in control of a vehicle is an offence. Under extended operation the and EM 100 MODULE modem will generate a noticeable amount of heat. Like all PC Cards, the modem generates heat during normal operation and will be heated by the host computer. For this reason it is recommended that after extended periods of operation, prior to removal and handling, you allow the modem to cool down. FCC ID label must be visible through a window on the final device or it must be visible when an access panel, door or cover is easily removed. If not, a second label must be placed on the outside of the final device that contains the following text: “Contains FCC ID: PU5-EM100” Federal Communications Commission Notice (FCC—United States) FCC applies to and EM 100 MODULE. Refer to sections on Regulatory Compliance for more details. Electronic devices, including computers and Corporationmodems, generate RF energy incidental to their intended function and are therefore subject to FCC rules and regulations. This equipment will be tested, and found to be within the acceptable limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment generates radio frequency energy and is designed for use in accordance with the manufacturer’s user manual. However, there is no guarantee that interference will not occur in any particular installation. If this equipment causes harmful interference to radio or television reception, which can be determined by turning the equipment off and on, you are encouraged to try to correct the interference by one or more of the following measures: • • • • Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/television technician for help This device complies with Part 15 of the Federal Communications Commission (FCC) Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Radio Frequency Exposure Evaluation Requirements This Corporationmodule is a radio transmitter and receiver. It is designed and manufactured not to exceed the exposure limits for radio frequency (RF) energy set by the Federal Communications Commission (FCC) of the U.S. Government. These limits are part of comprehensive guidelines and of 27 11 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification establish permitted levels of RF energy for the general population. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons, regardless of age and health. The exposure standard for Corporationdevices including mobile phones and Corporationmodems uses a unit of measurement known as the Specific Absorption Rate, or SAR. Tests for SAR are conducted using standard operating positions reviewed by the FCC with the device under test. This device is to be used only for mobile and fixed applications. The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. transmitting at its highest certified power level in all frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the phone or modem while operating can be well below the maximum value. This is because the phone or modem is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a Corporationbase station antenna, the lower the power output. Before this device is made available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government-adopted requirement for safe exposure. The tests are performed in positions and locations (for example, at the ear or worn on the body) as required by the FCC for each model. In general, for the United States market, the embedded modules are treated as “mobile devices” as per FCC CFR47 paragraph 2.1091. A mobile device is defined as “a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 cm is normally maintained between the transmitter’s radiating structure(s) and the body of the user or nearby persons.” Manufactures of mobile devices may be able to submit a Maximum Exposure Rate (MPE) calculation in order to demonstrate SAR compliance. of 27 12 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Canada. Industry Canada (IC) IC: RF exposure evaluation is required if the separation distance between the user and the device is greater than 20 cm, except when the device operates: • below 1.5 GHz and its e.i.r.p. is equal to or less than 2.5 W; • at or above 1.5 GHz and the e.i.r.p. of the device is equal to or less than 5 W. Mobile stations are limited to 2 watts maximum EIRP. The equipment shall employ means to limit the power to the minimum necessary for successful communication. CE (Conformité Européenne or European Conformity) This module will be tested to and conforms to the regulatory requirements of the European Union and has attained CE Marking. The CE Mark is a conformity marking consisting of the letters "CE". The CE Mark applies to products regulated by certain European health, safety and environmental protection legislation. The CE Mark is obligatory for products it applies to: the manufacturer affixes the marking in order to be allowed to sell his product in the European market. Radiocommunications and Telecommunications Terminal Equipment Industries (R&TTE) This is mandatory for European operation and the directive applies to products using the radio frequency spectrum and all equipment attached to public telecommunications networks. This product conforms to the essential requirements of the Radiocommunications and Telecommunications Terminal Equipment Directive (R&TTE) 1999/5/EC with respect to the following articles: • 3.1a Safety • 3.1b EMC • 3.2 Spectrum A notified body will determine that this device has properly demonstrated that the requirements of the directive have been met and has issued a favorable certificate of expert opinion. As such the device will bear the notified body number (TBD) after the CE Mark. of 27 13 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Compliance & Certification Requirements PCS Type Certification Review Board (PTCRB) PTCRB Certification is mandated and the product is technically evaluated to meet the minimum requirements for registration on the PTCRB Operators’ networks. The purpose of the PTCRB is to provide the framework within which GSM Mobile Equipment (ME) Type Certification can take place for members of the PTCRB. The PTCRB process is recommended for all Manufacturers who wish to have their products operating within the areas served by the PTCRB Operators. This includes but is not limited to determination of the test specifications and methods to implement the Type Certification process for GSM Mobile Equipment. PTCRB type certification will be based on GSM and OMA (Open Mobile Alliance) Specifications with modifications per North American Standards and additional requirements from FCC rules, and any other government agency that may have jurisdiction and or competence in the matter. Additions to the PTCRB Specifications will be developed by the GSM operators. The additions will be limited to MS-related features. The PTCRB document NAPRD 03 (Permanent Reference Document) will be modified to include references to the above specifications once they are written and accepted by majority of the review board. To learn more about device certifications, please visit the a member to gain access PTCRB Website. You must sign up as Global Certification Forum (GCF), The Global Certification Forum (GCF) is an independent organization with a wide-ranging membership of operators, equipment manufacturers and other interested parties. The actions of the Forum are actively supported by key staff from the Association Technical Projects operation and by the Association Executive Management Committee. GCF is recommended but not mandatory for attachment to the European network. It is a partnership between network operators and terminal manufacturers and allows independent interoperability validation of the 2G and 3G mobile Corporationterminal. GCF is typically required for formal carrier technical acceptance of the mobile Corporationterminal. Membership of GCF is entirely voluntary. Full GCF membership is open to mobile terminal manufacturers and network operators. Other interested members of the mobile wireless community, including test laboratories and test equipment manufacturers, may participate in GCF as observers. The current membership includes almost 150 network operators worldwide, more than 35 leading terminal manufacturers and over 50 test equipment manufactures. Members decide the organization and administration of the forum at regular Steering Group meetings. Technical issues of 27 14 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification associated with testing new terminals and features are reviewed at regular Agreement Group meetings by manufacturers, test laboratories and other observers. To learn more about device certifications, please visit the GCF Website. The website identifies manufacture, terminal names and the date which the terminal was certified. You must sign up as A member to gain full access. of 27 15 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Getting Started General The purpose of this document is to provide advance design and integration information to assist in the integration planning and evaluation of Wistron CorporationUSB Cards. This document is intended to specify key components of the integration tools available for the Wistron Corporationline of USB Cards. TheEM 100 MODULE are Wistron Wireless’ versatile modules that add WWAN capability to other devices. They were developed to be integrated into other devices based on the USB Card specification 1.2 The EM 100 MODULE will work with all Windows driven laptops given the drivers are properly installed. When MobiLink™ is installed on a Windows OS system it will automatically include the drivers necessary to communicate with the USB Card. MobiLink™ is Wistron’s Windows application manager for the EM 100 module. MobiLink provides an easy interface to make a data connection, change operating parameters, and view alerts such as SMS or signal strength indicator. However, anyone can still install the drivers manually. In addition, once the drivers are installed, following the Wistron Client API functions, anyone could develop their Client side software manager to interact with the USB Card. When using any of these devices, EM 100 MODULE, activation is required for the device to be allowed on the operator’s network. For example, Sprint requires the customer to run IOTA (Internet Over-The-Air) provisioning to prepare the device to work on the Corporationnetwork. Please refer to the Customer Configuration section on provisioning with IOTA for assistance. The EM 100 MODULE and require a valid SIM card before it can be used on the operator’s Corporationnetwork. Please refer to the Customer Configuration section on PRI for further information. Setting Up The purpose of this section is to assist in the initial connection and provide the reader with instructions for how to setup and establish communication with the Wistron Corporationline of USB Card. The following setup guide refers to an EM 100 MODULE EDGE Mini-card for convenience of the set up discussion. The same setup is valid for both the EM 100 MODULE EDGE and Mini-cards. Setting up and establishing communication with the Wistron CorporationUSB Card involves: Connecting the USB Card to the computer and the Development Board. Establishing communication with the USB Card and determining the computer COM Port being used. Setting up and using the HyperTerminal program to communicate with the Mini-card CONNECTING THE USB CARD TO THE COMPUTER AND THE DEVELOPMENT BOARD Insert the USB Card into the Development Board (Wistron CorporationPart # 01017568) by sliding the connector end of the Mini-card into the Molex connector. Push down on the opposite end of the Mini-card until the 2 black locking tabs snap into place. of 27 16 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification EM 100 MODULE EDGE Module Key Feature List Feature Implementation General Frequency bands Quad band: GSM 850/900/1800/1900MHz GSM class Small MS Output power (according to Release 99, V5) Class 4 (+33dBm ±2dB) for EGSM850 Class 4 (+33dBm ±2dB) for EGSM900 Class 1 (+30dBm ±2dB) for GSM1800 Class 1 (+30dBm ±2dB) for GSM1900 Class E2 (+27dBm ± 3dB) for GSM 850 8-PSK Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK Class E2 (+26dBm +3 /-4dB) for GSM 1900 8-PSK Power supply 3.2V to 4.3V Ambient operating Normal operation temperature according to IEC 60068-2 Physical -20°C to +65°C Dimensions: 33.9mm x 44.6mm x max. 3.4mm Weight: approx 8.5g of 27 17 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification RoHS All hardware components fully compliant with EU RoHS Directive GSM / GPRS / EGPRS features Data transfer GPRS • Multislot Class 12 • Full PBCCH support • Mobile Station Class B • Coding Scheme 1 – 4 EGPRS • Multislot Class 12 • Mobile Station Class B • Modulation and Coding Scheme MCS 1 – 9 CSD • V.110, RLP, non-transparent • 2.4, 4.8, 9.6, 14.4kbps • USSD PPP-stack for GPRS data transfer SMS • Point-to-point MT and MO • Cell broadcast • Text and PDU mode • Storage: SIM card plus 25 SMS locations in mobile equipment • Transmission of SMS alternatively over CSD or GPRS. Preferred mode can be user defined. Fax Group 3; Class 1 of 27 18 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Audio Speech codecs: • Half rate HR (ETS 06.20) • Full rate FR (ETS 06.10) • Enhanced full rate EFR (ETS 06.50/06.60/06.80) • Adaptive Multi Rate AMR Line echo cancellation, DTMF,TBD ringing tones Software AT commands AT-Hayes GSM 07.05 and 07.07, Wistron AT commands for RIL compatibility (NDIS/RIL) RIL / NDIS for Pocket PC and Smartphone MicrosoftTM compatibility SIM Application Toolkit SAT Release 99 TCP/IP stack Access by AT commands IP addresses IP version 6 Remote SIM Access By case (Standard none support) EM 100 MODULE supports Remote SIM Access. RSA enables EM 100 MODULE to use A remote SIM card via its serial interface and an external application, in addition to the SIM card locally attached to the dedicated lines of the application interface. The connection between the external application and the remote SIM card can be a Bluetooth wireless link or a serial link. The necessary protocols and procedures are implemented according to the “SIM Access Profile Interoperability Specification of the Bluetooth Special Interest Group” (SAP). Firmware update Windows executable for update over serial interface ASC0. of 27 19 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification • • 8-wire modem interface with status and control lines, unbalanced, asynchronous Fixed bit rates: 300bps to 460,800bps Autobauding: 1,200bps to 460,800bps Supports RTS0/CTS0 hardware handshake and software XON/XOFF flow control. Multiplex ability according to GSM 07.10 Audio • 2 analog interfaces SIM interface Supported SIM cards: 3V, 1.8V Antenna 50Ohms. External antenna can be connected via antenna connector or solderable pad. Module interface 80-pin board-to-board connector 1 serial interfaces • • • Power on/off, Reset Power on/off • • Reset • Switch-on/off by hardware pin IGT Switch-off by AT command (AT*WPOOF) Emergency off reset by hardware pins EMERG_RST and IGT. Special features of 27 20 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Real time clock Timer functions via AT commands Phonebook SIM and phone Evaluation kit EM 100 MODULE evaluation board EM 100 MODULE evaluation board Evaluation Board designed to test and type approve Wistron cellular engines and provide a sample configuration for application engineering. Card Specifications The EM 100 MODULE are designed to meet the EM 100 module electromechanical card standard with some exceptions to accommodate the power requirements. These modules all support only the USB portion of the minicard standard. Chipset The AD6532 ADI baseband processor,PM6855 power management IC, AD6546 shall be the chipset used. EM 100 MODULE The EM 100 MODULE EDGE USB Card baseband incorporates the ADI baseband processor and the PM6650 power management IC. Mobile stations are limited to 2 watts maximum EIRP. The equipment shall employ means to limit the power to the minimum necessary for successful communication. of 27 21 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Figure 1 – Modem Interface Board and Cables ESTABLISHING COMMUNICATION WITH THE USB CARD AND DETERMINING THE COMPUTER COM PORT BEING USED Once the modem is powered up and connected, you should hear a sound indicating the computer has recognized the modem. Determining the Computer’s Active Primary COM Port To verify the computer’s recognition of the modem and to verify which Primary COM Port it is connected to, navigate to Start\Control Panel\Phone and Modem Options and then click on the Modems tab within the Phone and Modem Options window. Refer to Figure 2 below. of 27 22 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Figure 2 – Phone and Modems Options Window Look for the Wistron CorporationMerlin EM 100 MODULE EDGE Modem item on the list. To the right of this item in the ‘Attached To’ column, you will see a COM port number - make a note of this Primary COM Port Number. If you do not see any COM No. for this item and you only see “Not Present”, then this indicates that the modem is not being recognized and is not attached to a COM Port on the computer. In this case, make sure the USB and power cable are properly connected at both ends. If the modem has properly booted up, with no SIM in the SIM holder, the WAN LED on the Development Board should be blinking at a steady rate. If there is a SIM in the SIM Holder, the LED will be solid green. Determining the Computer’s Active Secondary or Status COM Port To verify which Secondary, or Status COM Port the modem is connected to, navigate to Start\Control Panel\System. After you have double-clicked on the System Icon, click on the Hardware Tab within the System Properties window. Now click on the Device Manager tab. In the Device Manager window, click on the “+” beside Modems to expand this item. You should now see the Wistron CorporationExpedite EM 100 MODULE EDGE Modem, or something similar listed here. of 27 23 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Refer to Figure 3 below. Now click on the “+” beside Ports (COM & LPT) to expand this item. You should now see the Wistron CorporationExpedite EM 100 MODULE EDGE Status Port (COM XX) listed here. This is the Secondary or Status COM port Number. Again, refer to Figure 3 below. Make a note of this Port Number. of 27 24 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Figure 3 – Device Manager Window Showing the Computer’s Active Status COM Port SETTING UP HYPERTERMINAL TO COMMUNICATE WITH THE MODEM Ensure that the Mini-card is still powered on with a USB connection to the computer, and that it is recognized by the computer as per the previous step. Open up a HyperTerminal session by navigating to Start\All Programs\Accessories\Communications\HyperTerminal. of 27 25 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification Type in a Connection Description title, such as the Active Primary COM Port number that was identified earlier - click ‘OK’. See Figure 4 below as an example: Figure 4 – HyperTerminal Connection Description Window In the “Connect Using” pull down menu, select the proper COM port (Primary COM port number), that the computer is using to communicate with the modem, then click ‘OK’. See the example in Figure 5 below: Figure 5 – HyperTerminal COM Port Selection Window of 27 26 EM100 Data Card Integration Guide R&D Division, Handheld & Mobile Communication, Taipei Design Center, Wistron Corp. Engineering Specification When the ‘COM XX Properties’ window comes up, just click on OK as there is no need to select or modify any of these settings. Refer to Figure 6 below: Figure 6 – HyperTerminal Properties Window Now the modem should be automatically connected, as will be indicated in the bottom left corner of the HyperTerminal window. To further ensure there is communication to the modem, type “ATI” and press ENTER. The modem manufacturer, model number, FW revision and IMEI information will then be returned as is shown in Figure 7 below. If no information is returned in the HyperTerminal window after typing ATI, then click on the Disconnect tab at the top of the HyperTerminal window (or click on Call\Disconnect). Reconnect by clicking on the Connect tab at the top of the HyperTerminal window (or click on Call\Connect). Now type ATE which will enable the “echo” function of the modem and therefore will allow the characters typed in the HyperTerminal window to be displayed. Once this has been done, retype the ATI command and all the modem information should now be displayed in the HyperTerminal window. Figure 7 – HyperTerminal Communication Window of 27 27
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.1.0 (Windows) Modify Date : 2008:01:07 15:29:29+08:00 Create Date : 2008:01:07 15:28:01+08:00 Metadata Date : 2008:01:07 15:29:29+08:00 Format : application/pdf Title : untitled Document ID : uuid:a7b6b479-4d38-49c3-936b-daff4ae61ab5 Instance ID : uuid:e449b2b5-2837-44bd-8714-e2a600eb2700 Page Count : 27EXIF Metadata provided by EXIF.tools