Wisycom s r l MTK952N-2W0 Dual Transmitter with / without Combiner User Manual CSI16T
Wisycom Dual Transmitter with / without Combiner CSI16T
Contents
- 1. User Manual
- 2. User Manual combiner-16-8-4
- 3. User Manual mtk952
- 4. Combiner User Manual
User Manual combiner-16-8-4

![Rev.01 CSI16T User Manual 1 INTRODUCTION CSI16T is a passive wideband combiner designed to work up to 3W of power. CSI16T communicates with Wisycom transmitter (i.e. MTK952N) through coaxial inputs and allows a smart power management: combiner loss are automatically compensate on Tx side! FEATURES RF combiner able to combine 16 inputs into 4/2/1 outputs Selectable combination thru a 3 positions selector on front panel [16:1] or 2x [8:1] or 4x [4:1] Used with MTK952N permits to recover the combiner loss Wide band operation 470÷800MHz High input power up to 3W SAFETY INSTRUCTION Read this safety instruction and the manual first Follow all instructions and information. Do not lose this manual. Do not use this apparatus under the rain or near the water. Do not install the apparatus near heaters or in hot environments, do not use outside the operating temperature range. Do not open the apparatus, only qualified service technician are enabled to operate on it. The apparatus needs servicing when it is not properly working or is damaged by liquids, moisture or other objects are fallen in the apparatus. Use only accessories or replacement parts authorized or specified by the manufacturer. Clean the apparatus only with dry cloths, do not use liquids. Report the serial number and the purchasing date in front of the manual. It is needed to have proper replacement parts or accessories from the manufacturer. When replacement parts are needed, use only replacement parts authorized from the manufacturer. Substitution with not authorized parts could result in electric shock, hazards or fire. Keep attention on all the labels with warnings or hazards on the apparatus.](https://usermanual.wiki/Wisycom-s-r-l/MTK952N-2W0.User-Manual-combiner-16-8-4/User-Guide-3079326-Page-2.png)


![CSI16T User Manual Rev.01 4 HOW TO USE & CONFIGURATION EXAMPLES Combiner loss can be automatically recovered from MTK952Ns connected to the smart combiner CSI16T: MTK952Ns raise power accordingly to the loss, while keeping the limit on output port (country based). Example1: Combiner 2x [8:1] configuration with high power transmitters: Country power limit:50mW Enabling external compensation on MTK952Ns, the transmitters raise power of 9dB in order to limit to 50mW the maximum power at the output of CSI16T. Example2: Combiner [16:1] configuration with high power transmitters: Country power limit:10mW Enabling external compensation on MTK952Ns, the transmitters raise power of 12dB in order to limit to 10mW the maximum power at the output of CSI16T. 50mW 400mW 160mW 10mW](https://usermanual.wiki/Wisycom-s-r-l/MTK952N-2W0.User-Manual-combiner-16-8-4/User-Guide-3079326-Page-5.png)
![Rev.01 CSI16T User Manual 5 TECHNICAL SPECIFICATIONS Bandwidth 470 MHz – 800MHz Input Connectors 16 BNC-F, 50 Ω of impedance Input Connectors 6 N-F, 50 Ω of impedance Max input power 3W (for each input connector) Combiner loss approx. 6 dB for 4x [4:1]* approx. 9 dB for 2x [8:1] * approx. 12dB for [16:1] * Power supply AC connector 90÷264Vac /47÷63Hz, (fuse protected) T2A-50W max DC connector 10÷ 28 Vdc Temperature range -25 ÷ +55 °C Case Aluminum, black varnish Weight 4,60 Kg Dimensions 19”/1U 483 x 398 x 44 mm (WxDxH) with brackets * Ports terminated at 50Ω (2Watt)](https://usermanual.wiki/Wisycom-s-r-l/MTK952N-2W0.User-Manual-combiner-16-8-4/User-Guide-3079326-Page-6.png)