Wisycom s r l MTP40SUSX Wideband bodypack transmitter User Manual MTP40S US USX

Wisycom Wideband bodypack transmitter MTP40S US USX

User Manual

                        MTP40S-US/USX  User Manual Wideband Wireless Professional Pocket Transmitter   SN:  ________________ Rev.02 (ref. FW 1.22.0D)  Date: 08 May 2014  MTP40 E-series
MTP40S-US/USX  User Manual Rev.02    2
MTP40S-US/USX  User Manual Rev.02    3 INTRODUCTION “MTP40S  is an extremely small and light pocket transmitter especially designed for professional wireless microphone applications” Very easy and quick to use thanks to OLED display, dedicated buttons and a joggle selector. MTP40S  benefits  also  of  the  latest  Wisycom  RF  technology  along  with  an  enhanced robustness against noise and inter-modulation.   Fig. 1           ❶ Switch to enable wireless transmission, it also indicates the battery status and peak/mute operation (with PTT) ❷ In order to allow front visibility same colour information on (1) is replicated with this LED ❸ Oled display for transmitter setup ❹ <ch>, <gain> and 3 positions <selector> ❺ Battery holder ❻ Cover (to open push side buttons)  1.                                                 6 5 4 3 2 Turn on wireless: Move the Wireless power switch in “I” position. 1 Open MIC Body: Push the side buttons and flip down the  cover, to access internal setup controls and batteries.           Turn on display: Push <select switch> and hold it.   Front  LED RGB. Fig. 2
MTP40S-US/USX  User Manual Rev.02    4                                                                                      SAFETY INSTRUCTION  Read this safety instruction and the manual first  Follow all instructions and information.  Do not lose this manual.  Do not use this apparatus under the rain or near the water.  Do not install the apparatus near heaters or in hot environments, do not use outside the operating temperature range.  Do not open the apparatus, only qualified service technician are enabled to operate on it. The apparatus needs servicing when it is not properly working or is damaged by liquids, moisture or other objects are fallen in the apparatus.  Use only accessories or replacement parts authorized or specified by the manufacturer.  Clean the apparatus only with dry cloths, do not use liquids.  Report the serial number and the purchasing date in front of the manual. It is needed to have proper replacement parts or accessories from the manufacturer.  When replacement parts are needed, use only replacement parts authorized from the manufacturer. Substitution with not authorized parts could result in electric shock, hazards or fire.  Keep attention on all the labels with warnings or hazards on the apparatus. LED INDICATIONS Led indication with LED RGB (red, green, blue) in front led (2): -  Wireless transmission status: Green when RF transmission power is on,    Red when RF transmission power is off.   Blue when the input signal is above the peak threshold  -  Battery status: green steady, slowly blinking (< 25%), quickly blinking (<12%). -  Modulation peek (if activated and the limiter is disabled): red.  -  Ptt status: red if active (push to talk “pushed”). BATTERIES MTP40S is working with 2 AA alkaline or NiMH batteries (select correct type on setup controls). Battery status can be checked on internal OLED display or looking to LED status on power switch (see 1.1).  BATTERY SUBSTITUTION   Open transmitter cover and insert batteries following polarity indicated.  Attention: always replace both the batteries
MTP40S-US/USX  User Manual Rev.02    5 POWERING UP Move the wireless power switch (see Fig. 1) in “I” position to activate wireless transmission: a green LED lights up (blinking when battery is low!) SETUP CONTROL Open transmitter Body to access the “display and controls” area (Fig. 3): A. Graphics Display (OLED) B. Channel selection buttons (ch) C. MIC gain setup buttons (gain) D. 3 position selector (up / down / click)                  Fig. 3  OLED POWER UP (OLED IS  IN OFF CONDITION) Pushing down selector (click), oled turns on. A first menu with serial NO and brand logo is displayed, then <status> menu enters automatically. Pushing and holding selector, serial NO menu is displayed.  OLED POWER DOWN (OLED IS IN ON CONDITION) Display turns off automatically after 15 sec, unless in <IRDA> menu or in <AUDIO> menu (with audio level < 5% from nominal).  + - CLICK  A  B  C  D
MTP40S-US/USX  User Manual Rev.02    6 DISPLAY MENU Setup menu are accessed in sequence:                                         MENU STATUS PRESET Current Load  FACTORY/USER/PRESET1/2/3/4/5/6/7/8 Save  USER TUNING CH 00-59 GR 00-39 Freq  1: 470.000÷640.000                                         2: 566.000÷798.000 3: 510.000÷698.000  AUDIO AF In Gain  -60÷40 dsB (1dB step) Phase  0/180 HPass Filter  Flat/60/80/120/170/250/400Hz Noise R.  ENR-Wisy/ENC-Wisy Limiter  On/Off MIC Mode  2 wires/2wires+bias/3 wires/ 2wire&pha/2w+bias&pha PTT Disable/Normal/Muting/No Data RF/Battery RF Power  10/50/100 mW Battery  Alkaline/NiMH LED Led Light  0÷16 Led Mode  None/ModPeak/PTT IRDA Lock Preset parameters
MTP40S-US/USX  User Manual Rev.02    7 + - CLICK Using <+/-> selector all menus can be accessed in sequence, push <click> to enter edit mode (in the left side of the display appear the word EDIT and the parameter start blinking): <+/-> to setup field <click> again to confirm changes and exit. exit without confirmation if no button is pressed after a few seconds time out.  <START UP> menu  These menus are displayed during power up for few seconds.      First one gives information of antenna to be used. The number displayed is the center-band of the antenna to be used.    The second menu gives indication on product: product id (MTP40S), a letter which identify the working band  1 470-640 2 566-798 3 510-698 a number which identify the hardware version, the firmware release (120.0B), the band in extended format and the serial number. Keep selector pushed to hold this menu! <STATUS> menu  This is the first menu displayed after power up.   Major info are displayed: - Current channel/group (i.e. CH:00 GR:39) - Current frequency (i.e. 566.000 MHz) - Mic gain (i.e. AF: +00 dB) and high pass filter (i.e. HP:60 Hz) - “RF 100” or RF 50” or “RF 10” on top right if RF transmission is on at 100mW or 50mW or 10mW of power respectively - On bottom battery bar is displayed <PRESET> menu  This menu can be entered by scrolling selector, or pushing at the same time both quick channel setup buttons (<ch> & <gain>).  MTP40S can recall configuration presets. “FACTORY” recalls the Wisycom factory configuration. “USER” recalls the user configuration (the transmitter configuration is copied into the USER using the “save to” submenu). All “USER” menus are not locked by default, thus this is quick way to unlock features! The  other    8  configuration  presets  are  user  programmable  thru  the  infrared  and  the  PC interface  (using  the  programmer  UPK  300  or  the  receiver  MRK950/MRK960). All parameters can be “left unchanged”, “changed” or “changed and lock”, allowing a very flexible way to pre-program MTP40S configuration.
MTP40S-US/USX  User Manual Rev.02    8 <TUNING> menu  This menu can be entered by scrolling selector or using quick channel setup buttons (<ch>).  In this menu current channel/group and frequencies can be setup. Use the selector to change values (<+/->) and <click> to confirm. Sync group is a quick self-settable channel synchronized by receiver. Using quick channel setup buttons (<CH>), it is possible to enter quickly in the tuning menu. Note that the menu has a different layout (see the side image) <AUDIO> menu  This menu can be entered by scrolling selector or using quick gain setup buttons (<gain>).         “AF In Gain” setup to tune audio input sensitivity: To help proper audio gain setting, an audio bar is supplied (with peak hold bar) indicating the headroom to audio peak (0dB)        TRY TO SETUP TO HAVE A MAX PEAK HOLD BAR CLOSE TO -6dB.   AF gain is shown with 2 different unit of measurements: dB (gain in dB of MTP40S amplifiers) or in dBµ peak, setting it with IR PROGRAMMER (see the picture on page 11 and the description on CURRENT SETTINGS PANEL). Using quick gain setup buttons (<GAIN>), it is possible to enter quickly in the audio gain menu. Note that the menu has a different layout (see the side image)                             The second <AUDIO> menu allows to set:  - Audio phase (0° or 180°) -High Pass Filter: applies different audio HP filter: Flat /60Hz /80Hz/120Hz /170Hz /250Hz /400Hz. Use the selector to change values (<+/->) and <click> to confirm.  The third <AUDIO> menu allows to set:  -Noise reduction:  ENR: designed for maximum noise reduction  ENC: designed for maximum audio fidelity (use this in case of special vocal application or to remote instruments) -Limiter: if is set “On”, an input audio signal above the peak threshold (up to 30 dB above peak) is not cut but attenuate, without lost quality. The limiter acts as a variable attenuator (thanks to the feedback system), maintaining a distortion <3%.                 When the limiter intervene, the front led turns blue.                     If this parameter is set “Off”, the limiter is disable. <RF/BATTERY> menu  This menu can be entered by scrolling selector.    RF power can be setup to 100mW(only USX option) or 50 mW or 10 mW. Use the Battery menu to select the type of battery used. MTP40S support Alkaline/NiMH battery type.
MTP40S-US/USX  User Manual Rev.02    9 Use the selector to change values (<+/->) and <click> to confirm. <LED> menu  This menu can be entered by scrolling selector.    Led Light allows to change the brightness of the front led (0÷16) .  Led Mode: - None: allows to disable modulation peak LED on front    led (the red light) - ModPeak: allows to enable modulation peak LED on front led (become RED when audio get close to saturation when the limiter is not enable) - PTT: allows to enable RED color on front led when PTT button is pushed. <MIC> menu  This menu can be entered by scrolling selector.   Mode: Following Mic mode can be setup (for LEMO option) -2 wires: (PTT is possible) for external audio input -2 wires + bias: (PTT is possible) for most 2 wires MIC -3 wires: (no PTT) for most 3 wires MIC -2 wires & pha: to connect a wired mic thru a 48V adapter (PHA48) -2 wires+bias & pha: Allow to connect a ‘2 wires + bias’ MIC or a ‘2 wires &  phantom’ MIC (with PHA48) PTT setting defines how and what information the transmitter has to send in normal use or when the PTT button is pushed. - Disable: when the PTT button is pushed, nothing happen. (the transmitter sends AF+Tone squelch) - Normal: when the PTT button is pushed, the transmitter send a different RF signal. According to the receiver configuration the audio can be enabled/disable on LINE (and/or COM). - Muting: the transmitter doesn’t send the audio. The voice is cut, it doesn’t enter to the  microphone - No Data: the transmitter sends neither tone squelch nor battery data. Use the selector to change values (<+/->) and <click> to confirm. NOTE: For DPA option (2 pin microdot audio connector), even if the MIC mode menu allows to set one of the 5 MIC modes, only 2 wires or 2 wires+bias mode are possible.  <IRDA> menu  This menu can be entered by scrolling selector.   While is this menu MIC can be connected to IRDA for setup or firmware upgrades. NOTE: while in this menu display is not automatically turned off. <LOCK> menu  This menu can be entered by scrolling selector.    Long pressing (2 sec.) selector button (click) it locks MTP40S in transmission mode. To unlock, long pressing (2 sec.) selector button again. <BOOTLOAD> menu  This menu can be entered only turning on the transmitter while pushing at the same time both quick channel setup buttons (<ch> & <gain>).
MTP40S-US/USX  User Manual Rev.02    10   Device is forced in bootloader mode to allow FIRMWARE UPDATE. The following table sums up which parameters can be set and the related range settings. MENU PARAMETER MEANING RANGE SETTINGS TUNING CH Channel 0 ÷ 59 GR Group 0 ÷ 39 + SYNC GROUP Freq Frequency depends on the MTP40S Model: 1  470-640 2  566-798 3  510-698 AUDIO AF In Gain Gain of the audio signal depends on the mic mode setting   (ex. -40dB ÷ 40dB step of 1 dB) Phase Audio signal phase 0° or 180°  HP Filt. High Pass filter Flat/60/80/120/170/250/400 Hz Noise R. Noise reduction ENR: Wisycom Extended-NR,noise optimized  ENC: Wisycom Extended-NC,voice optimized Limiter Limiter On/Off RF/BATTERY RF Power RF Power 10mW or 50mW or 100mW(only USX option) Battery Battery type Alkaline or NiMH LED Led Light Power switch green brightness 0 ÷ 16 Led Mode It defines  when the power switch led   (see Fig. 3) has to become RED None: never ModPeak: when audio get close to saturation PTT: when the PTT button is pushed MIC Mode MIC type ’2 wires’ ‘2 wires + bias’ ‘3 wires’ ‘2 wires &  phantom’ ‘2 wires + bias &  phantom’ PTT Mode It defines how and what information the transmitter has to send  Disable:when the PTT button is pushed, nothing happen. (the transmitter sends AF+Tone squelch) Normal: when the PTT button is pushed, the transmitter send a different RF signal. According to the receiver configuration the audio can be  enabled/disable  on LINE (and/or COM).  Muting: the transmitter doesn’t send the audio. The voice is cut, it doesn’t enter to the microphone No Data: the transmitter sends neither tone squelch nor battery data.
MTP40S-US/USX  User Manual Rev.02    11  MIC Mode setting (only for LEMO option): MIC Mode: Pin out Gain PTT Led Mode ’2 wires’:     1=GND 3=AF -60/40 dB Disable  Normal  Muting  No data None Mod. Peak PTT ‘2 wires + bias’:  1=GND 3=AF+5.5V -60/40 dB Disable Normal Muting No data None Mod. peak PTT ‘3 wires’:  1=GND 2=5.5V 3=AF -60/40 dB Disable No data None Mod. peak ‘2 wires &  phantom’: 1=GND 2=3.1V (power for PHA48) 3=AF -60/40 dB Disable No data None Mod. peak ‘2 wires + bias &  phantom’: 1=GND 2=3. 1V (power for PHA48) 3=AF+5,5V -60/40 dB Disable No data None Mod. peak
MTP40S-US/USX  User Manual Rev.02    12 ACCESSORIES AND PARTS  AWF30-B1-507 For MTP40S-X-X1 Band 470 ÷ 547 MHz Antenna Code label 507 AWF30-B1-590 For MTP40S-X-X1 Band 547 ÷ 640 MHz  Antenna Code label 590  AWF30-B2-616 For MTP40S-X-X2 Band 566 ÷ 672 MHz Antenna Code label 616 AWF30-B2-732 For MTP40S-X-X2 Band 672 ÷ 798 MHz  Antenna Code label 732 AWF30-B3-552 For MTP40S-X-X3 Band 510 ÷ 595 MHz  Antenna Code label 552 AWF30-B3-646 For MTP40S-X-X3 Band 595 ÷ 698 MHz  Antenna Code label 646  CAL48 Cable to connect an MTP30 (with option /PHA) or MTP40/40S to a PHA48 to use microphone with XL3/48V connection    CAL120 AF cable (120cm), LEMO 3pole / XLR-3F connectors PHA48 Plug-on for XLR3 Mic with 48V Phantom power. To be used with CAL48 (connected to an MTP30/40/40S) NEW REV2 with 4mA Phantom current!  ADT40 Power Adapter for MTP30/40/40S. Power input: 9-18V DC feeding (internal switching regulation). variants: ADT40: without connector (pigtail)  ADT40X: with XLR-4pin power connector ADT40H: with Hirose-4pin power connector NOTE: MTP30/40/40S must have ADT option to pass thru cable UPK300E Infrared programming kit (interface + software) USB interface     Antenna Code label
MTP40S-US/USX  User Manual Rev.02    13 WISYCOM IR PROGRAMMER (VER. 1.3.2.8 AND ABOVE) Wisycom IR Programmer allows to read, modify and update the MTP40S  device configuration.  It is necessary to   install Wisycom IR Programmer (version 1.3.2.8 or above) WARNING: If  it is the first installation and Wisycom USB driver has not already installed in the PC, install the USB driver (run C:\Program Files (x86)\Wisycom\MTP&MTH Infrared Programmer (TX)\Drivers\ DriverInstaller.exe)  connected the programmer UPK300 or the receiver MRK950/MRK960 to the PC through USB connection   run the program  enable the IRDA communication on the transmitter (see IRDA menu) NOTE: Wisycom IR Programmer doesn’t work whit MRK950/MRK960 if it is connected to the PC using an Ethernet cable.  The Wisycom IR Programmer’s window is divided in 4 parts (see Fig. 5): ❶Interface and Device panel contains all the major information of the connected device  ❷Current Settings panel shows the current configuration. Thanks the PRESET panel, a previous saved configuration can be chosen and loaded like current setting. ❸Tuning Frequencies panel allows to handle Groups, Channels and Frequencies ❹Presets panel allows to read, change and save different configurations ❶ ❷ ❸ ❹ Figure 5: Wisycom IR Programmer’s window
MTP40S-US/USX  User Manual Rev.02    14 10 different configurations are available: • FACTORY configuration is a locked configuration: no parameter can be changed.  USER configuration is the only configuration that can be saved using the OLED display (see <PRESET>  menu). Note: It is not possible to change the name of this configuration.  Other 8 configurations where the user can change both the name and the values of all parameters.   INTERFACE AND DEVICE PANEL At the beginning, the program checks which IR devices are detected and they appears on the Interface panel. The user has to select the device and push <connect> button in order to open the communication with the IR device. A picture on the top in the Interface panel help the user in this selection showing the type of devices detected. During this process the “IR activity” led blinks to indicate that the program wait connection’s answer from the IR device.  A successful connection is signaled with the “interface connection” green led, while a failed connection is signaled with the “communication error” led. Once a supported device is found, the software automatically reads all the data related to the remote configuration, as well as the frequencies that are pre-programmed.  Firstly, in order to avoid unwanted operation, no parameters can be changes and the EDIT button, presents on the bottom of Device panel, is yellow and set to LOCKED state.  Pushing the EDIT button, it becomes grey and sets to UNLOCKED state to indicate that the configurations can be modified. CURRENT SETTINGS PANEL In the Current Settings panel the user can  with Preset panel → load one of the 10 available configurations   with other panels → modify all the configuration’s parameters (the same that are changeable in the OLED display). Each parameter can be locked clicking the related lock button, so the set value cannot be changed next using the OLED display. In the audio panel it’s also possible to change the unit of measurements of the gain choosing between dB (gain in dB of MTP40S amplifiers) or in dBµ peak.     ATTENTION: All the modifies applied to the Current Settings panel are instantaneous: they are applied directly to the device and save in its memory but no saved in the preset configuration.
MTP40S-US/USX  User Manual Rev.02    15 TUNING FREQUENCIES PANEL With the Tuning Frequencies panel the user can select a frequencies group (0÷39) and for each one execute the following operations: - modify the Group’s Name  - lock and/or hidden the group - for each channel (0 ÷59) of the selected group: change the frequency value and the related status (locked/hidden) (in the center grid frequency) The SAVE button, at the top of the panel, save the changes of the group selected (name group, lock/hidden group).   To change a frequency value  for  a  specific channel:  double  click on  the  grid  frequency panel  (row=channel’s number),  insert  the new  frequency  value and press OK button.   To lock/hide a specific channel, double click on the grid frequency panel.  NOTE: keeping pressed the CTRL button on the keyboard and clicking the wanted channel/group shown on the frequencies grid, the tuning process is executed. It is equivalent to configure the Tuning in the Current Settings panel but it is easier.  The device is re-tuned immediately, so be sure that the RF power is turned off while changing frequencies with other RF systems in use around you! If the currently tuned channel is on the same group that is listed on the grid, the background color of the related cell (channel) on the grid becomes yellow.
MTP40S-US/USX  User Manual Rev.02    16  Using the LOAD/SAVE button, at the bottom of the panel, it is possible to load/save the frequencies for the selected group from/to a .wdf file. To save the frequencies of all the groups click to the related button above. The legacy option save the channels without the hidden/lock info.
MTP40S-US/USX  User Manual Rev.02    17 PRESETS PANEL The Preset panel allows to manage all the 10s available configurations. For each configuration it is possible to set the name and all the parameters value except for FACTORY and USER configurations (see table below). PRESETS: NAME* LOCK/DON’T CARE PARAMETERS VALUE FACTORY    USER   √ OTHERS √ √ √ √=change is allowed * Be careful to write a meaningful name for the preset because the name will appear on the settings list of the device menu! Please, avoid empty names.  If a parameter is “locked”, it cannot be modified by device menu (using OLED display), while if “don’t care” propriety is active, when the user load the configuration, the parameter’s value doesn’t changed. ATTENTION: Changes are applied only after a “save” action. NOTE: “a trick” In case of the user have a locked parameter and he is in great need for modify it, he can save the configuration to USER configuration by OLED (see PRESET menu) and then load the USER configuration (in this way all the parameters have the lock propriety disable and the user can modify all the parameters).   FILE MENU Using a file menu at the top left of the panel it is possible to load/save all the configuration values of the device to/from a .wcf file (Wisycom Configuration File). Save a .wcf file With an infrared device correctly connected, select File->Save User Configuration and select the destination file.  Load a .wcf file  To load a user configuration select File->Load User Configuration and select a previously saved data file; a form will be shown, where it's possible to select which data has to be restored and which skipped. This allow the user to load a particular configuration while keeping other data.
MTP40S-US/USX  User Manual Rev.02    18 TECHNICAL SPECIFICATIONS Switchable channels 2400 allocated by 40 groups of  60 channels (in specific frequency range), quickly selectable with dedicated buttons Switching window Up to 90 MHz, depending on band (see below code table) Frequencies Quartz PLL  frequency synthesizer circuit (25 kHz step) Frequency stability ± 2,5 ppm (in the rated temperature range) Temp. range -10 ÷ +55 °C Max RF power ▪  50 mW (ERP) for US option ▪  100 mW (ERP) for USX option* Spurious emissions < 2 nW Modulation wideband FM, with 50 µs pre-emphasis Nominal deviation ±40 kHz  (Peak deviation =  ±56 kHz) Telemetry feature MTP40S transmits also a digitally modulated sub-carrier, suitable for:   ▪tone-squelch operating     ▪ remote battery monitoring   ▪ optional PTT (push to talk) operation  AF input connector LEMO option Configurable on ‘mic’ display menu in 5 options: ▪ ’2 wires’:     ▪ ‘2 wires + bias’:  ▪ ‘3 wires:  ▪ ‘2 wires &  phantom’  ▪ ‘2 wires + bias &  phantom’:  gain selectable -60 ÷ +40 (-54 dBu ÷ +26 dBu peak), no bias voltage gain selectable -60 ÷ +40 (-54 dBu ÷ +  6 dBu peak), 5.5 V on 4k7 bias supply gain selectable -60 ÷ +40 (-54 dBu ÷ +26 dBu peak) gain selectable -60 ÷ +40 (-54 dBu ÷ +26 dBu peak),  gain selectable -60 ÷ +40,(-54 dBu ÷ +  6 dBu peak), 5.5 V on 4k7 bias supply  AF input level 80 dB adjustable range from -60 dBu (775 uV) to 26 dBu (15.5 V) at peak deviation (1 kHz),  adjustable in 1 dB steps Max. input level +26 dBu (15.5 V) at clipping, +20 dBu (7.75 V) at nominal level Noise-Reduction ENR  (Wisycom Extended-NR), with independent Attack- and Recovery-time, noise optimized ENC  (Wisycom Extended-NC), with independent Attack- and Recovery-time, voice optimized & with reduced pre-emphasis AF bandwidth ▪  45 Hz ÷ 21 KHz (3dB) ▪  55 Hz ÷ 20 KHz (1dB) Distortion < 0.3 %   (0.15 % typ.) Signal-to-noise ratio ▪  typ. 115 dB (A)rms with 40 kHz deviation ▪  typ. 121 dB (A)rms with 56 kHz deviation Led Led indication with RGB led (red, green, blue) on wireless power switch: ▪   Wireless transmission status:       GREEN on/off ▪   Battery lifetime status: GREEN - steady (> 25%) - slowly blinking (< 25%)  - quickly blinking  (<12%) ▪   Modulation peek (if activated & the limiter is disabled): RED ▪   Ptt status: RED if active ▪   Limiter into action: Blue  Display High contrast OLED (Organic light-emitting diode) bicolor display (96 x 36 pixels) 8 step battery lifetime indication: 7 bars (100%-87%-75%-63-50%-38%-25%) and “empty bar” quickly blinking (12% remaining)  PTT function Pin 3 of the AF connector can be setup to an external push button Power supply 2 AA size batteries (Alkaline, rechargeable NiMH) MTP40S Battery life (2 AA alkaline) ▪  approx. 10 hours @ 50mW continuous working ▪  approx. 14 hours @ 10mW continuous working Dimensions 73 x 61 x 17.5 mm (Height-Width-Depth) without clip  Weight Approx. 80 g. without batteries (120g with batt.)
MTP40S-US/USX  User Manual Rev.02    19 In compliance with USA  PART 74 FCC-ID: POUMTP40              MTP40S US option FCC-ID: POUMTP40SUSX    MTP40S USX option Limited to 698 MHz Canada RSS-123, IC: 11967A-MTP40SUSX      MTP40S USX option           *in accordance with KDB 447498 D01 General RF Exposure Guidance v05r02.                    MTP40S  GND 5.5V (3 wires)  AF  AF + 5.5V (2 wires) Option      L Lemo Conn.
MTP40S-US/USX  User Manual Rev.02    20 MANUFACTURER DECLARATIONS In compliance with the following requirements  RoHS Directive (2002/95/EC)   WEEE Directive (2002/96/EC) Please dispose of the diversity transmitter at the end of its operational lifetime by taking it to your local collection point or recycling center for such equipment     Battery Directive (2006/66/EC) The supplier batteries or rechargeable batteries can be recycled. Please dispose of them as special waste or return them to your specialist dealer. In order to protect the environment, only dispose of exhausted batteries.  FCC Conformity   The Wisycom microphone pocket transmitter model MTP40S complies with the following requirements:  - FCC (Federal Communications Commission) Part 74 Operation is subject to the following two conditions:  (1) This device may not cause harmful interference, and  (2) This device must accept any interference received, including interference that may cause undesired operations.  Changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  FCC ID can be found inside the battery compartment. FCC-ID: POUMTP40              MTP40S US option FCC-ID: POUMTP40SUSX    MTP40S USX option
MTP40S-US/USX  User Manual Rev.02    21 Industry Canada Conformity (MTP40S USX)  EN This device complies with Industry Canada RSS-123. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.  FR Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio RSS-123. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
MTP40S-US/USX  User Manual Rev.02    22
MTP40S-US/USX  User Manual Rev.02    23
         Wireless System Communications  Via Spin 156    I-36060 Romano d’Ezzelino    Italy Tel. +39 -0424 -382605    Fax +39 - 0424 - 382733 www.wisycom.com    e-mail: sales@wisycom.com