1 PREFACE  Thank you for purchasing a Kipor generator.   This manual covers operation and maintenance of the IG2000i generators including parallel versions. All information in this publication is based on the latest product information available at the time of approval for printing. We  reserve  the  right  to  make  changes  at  any  time  without  notice  and  without incurring any obligation. No part of this publication may be reproduced without written permission. This manual should be considered a permanent  part of the generator and should remain with it if it is resold. Pay special attention to statements preceded by the following words: Failure  to  properly  follow  these  precautions  can  result  in property damage, serious injury or DEATH!   Read all labels and the owner's manual before operating this generator. Generators produce carbon monoxide, a poisonous, colorless, odorless gas that can cause death or serious injury.   Indoor use of a generator can kill quickly. Generators should be used outdoors only Generators  should  be  used  outdoors  only  and  away  from garages and open windows and protected from rain and snow. Check for spilled fuel or leaks. Clean and/or repair before use. Always  stop  engine  before  refueling. Wait  5  minutes  before restarting. Keep any source of ignition away from fuel tank, at all times. The  portable  generator  is  not  meant  to  be  used  as  a permanent  back-up  power  system  for  the  home.  A permanently installed stationary generator is designed to be safely used for this specific purpose.
2 Indicates a strong possibility of severe personal injury or death if instructions are not followed.  Gives helpful information.  If a problem should arise, or if you have any questions about the generator, consult an authorized dealer. Our  generators  are  designed  to  give  safe  and  dependable  service  if  operated according  to  instructions.  Read  and  understand  the  Owner's  Manual  before operating the generator. Failure to do so could result in personal injury or equipment damage. The Environmental Protection Agency (EPA) recently gave approval for gas stations to start selling 15% ethanol-blended fuel (E15).    E15 gas is now legal for use in cars, pickups, and SUVs manufactured since 2001.    However, E15 IS NOT approved for off-road engines.    This includes engines used in portable generators.    Utilizing E15 in outdoor power equipment can cause permanent, irreversible damage, and void warranties.  The  following  guidelines  will  help  consumers  properly  fuel  their  outdoor  power equipment: ●  Read  and  follow  your  owner’s  manual.    The  manual  will  clearly  explain  what fuels can be used to ensure a properly functioning product. ●  Don’t put any fuel containing more than 10 percent ethanol (E10) into small gas engine products. ●  Check the gas pump to be sure that it is dispensing E10.    Some pumps at local gas stations may offer both E10 and E15, or have blender pumps that dispense mid-level ethanol fuels for “flex-fuel” automobiles. ●  Higher  ethanol  fuel  (E15)  may  be  less  expensive  than  regular  (E10)  fuel,  but putting E15 into an E10 approved product could cause product failure and void its warranty. ●  Ethanol fuel will go through phase separation if not used immediately, (wicking moisture from the air) so always keep your extra fuel in an airtight container and try to avoid storing it in a place that is subject to temperature swings. ●  Use a fuel stabilizer if the engine will sit for more than a week without use; this will help to reduce the ethanol–water separation and potential gumming issues. It is best to run the engine for at least 20 minutes, under a 50% or more load every 3-4 weeks.
3 CONTENTS PREFACE ................................................................................................................... 1 1. SAFETY INSTRUCTIONS ...................................................................................... 4 2. SAFETY LABEL LOCATIONS ................................................................................. 6 3. COMPONENT IDENTIFICATION ............................................................................ 7 4. PRE-OPERATION CHECK ................................................................................... 10 5. STARTING THE ENGINE ...................................................................................... 14 6. GENERATOR USE ............................................................................................... 16 7. STOPPING THE ENGINE ..................................................................................... 25 8. PARALLEL GENERATOR OPERATION ................................................................ 27 9. MAINTENANCE .................................................................................................... 31 10. TRANSPORTING/STORAGE.............................................................................. 38 11. TROUBLESHOOTING ........................................................................................ 40 12. SPECIFICATIONS .............................................................................................. 42 13. WIRING DIAGRAMS ........................................................................................... 43 14. WARRANTY........................................................................................................ 44
4 1. SAFETY INSTRUCTIONS  ■  This generator is designed to give safe and dependable service if operated according to instructions. Read  and  understand  the  Owner's  Manual  before operating the generator. Failure to do so could result in personal injury or equipment damage.  ■  Exhaust  gas  contains  poisonous  carbon  monoxide. Never run the generator in an enclosed area. Never run the generator near a building or open window. Be sure to provide adequate ventilation.    ■  The  muffler  becomes  very  hot  during  operation  and remains  hot  for  several  minutes  after  stopping  the engine. Be careful not to touch the muffler while it is hot. Let the engine cool before storing the generator indoors. ■  The  engine  exhaust  system  will  be  heated  during operation and remain hot immediately after stopping the engine. To prevent scalding, pay attention to the warning marks attached to the generator.     ■  Gasoline is extremely flammable and explosive under certain conditions. Refuel in a well ventilated area with the engine stopped. ■  Keep away from smoking materials,  sparks and other  sources of combustion when refueling the generator. Always refuel in a well-ventilated location. ■  Wipe up spilled gasoline immediately.
5   ■  Always make a pre-operation inspection before you start the engine. You may prevent an accident or equipment damage. ■  Place the generator at least three feet or one meter away from buildings or other equipment during operation. ■  Operate the generator on a level surface to prevent fuel spillage or oil starvation. ■  Know how to stop the generator quickly and understand operation of all controls. Never permit anyone to operate the generator without proper instructions. ■  Keep children and pets away from the generator when it is in operation. ■  Keep away from rotating parts while the generator is running. ■  The generator is a potential source of electrical shock when misused; do  not operate with wet hands.   Do not operate the generator in rain or snow and do not let it get wet.    This  device  complies  with  part  15  of  the  FCC  Rules.  Operation  is  subject  to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes  or  modifications  not  expressly  approved  by  the  party  responsible  for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide  reasonable  protection  against  harmful  interference  in  a  residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference  to  radio  communications.  However,  there  is  no  guarantee  that interference will not occur in a particular installation. If this equipment does cause harmful interference to  radio or  television reception, which can be  determined  by turning  the  equipment  off  and  on,  the  user  is  encouraged  to  try  to  correct  the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help.
6 2. SAFETY LABEL LOCATIONS  These labels warn you potential  hazards that  can cause serious injury.  Read the labels and safety notes and precautions described in manual carefully. If a label comes off or becomes hard to read, contact your dealer for a replacement.
7 3. COMPONENT IDENTIFICATION
8 Control panel   Serial number identification and location The  generator  serial  number  identifies  your  particular  unit  and  is  important  when ordering parts and accessories. The number is found on a sticker on the carton and on the quality certificate in the carton along with the accessories and owner’s manual. It is also  stamped on the engine block visible when the service door is removed. Product registration is required for any future warranty claims. Register your product at www.kiporpowerequipment.com
        IG2000i: above right of the dipstickPlease record this information below and keep this manual in a safe place along with the bill of sale. Serial Number __________________________________Date and Place of Purchase __________________________________________Proof  of  purchase  is  required  for  any  future  warranty  repair.  The  customer  must supply a copy of the proof of purchase to the qualified Kipor srequesting warranty.   9 IG2000i: above right of the dipstick  Please record this information below and keep this manual in a safe place along with Number __________________________________ Date and Place of Purchase __________________________________________Proof  of  purchase  is  required  for  any  future  warranty  repair.  The  customer  must supply a copy of the proof of purchase to the qualified Kipor service center when Please record this information below and keep this manual in a safe place along with Date and Place of Purchase __________________________________________ Proof  of  purchase  is  required  for  any  future  warranty  repair.  The  customer  must ervice center when
4. PRE-OPERATION CHECK  ■ Be sure to check the generator on a level surface with the engine stopped. 1. Check the engine oil level.   ■ Using non detergent oil or 2 cycle engine oil could shorten the engine's Use a high-detergent, premium quality 4U.S. automobile manufacturer's requirements for API Service Classification SG/SF. Select the appropriate viscosity for the average temperature in your or 10W – 40 should be an acceptable oil for most climates. DO NOT use synthetic oil or semigenerator engine. The reasons for this are many, but may include: not allowing the engine to properly “breakplugs,  etc.  Engine  issues  that  are  caused  by  the  use  of  synthetic  oil  may  not  be covered under the warranty.       Single ViscosityMultiviscosity10 OPERATION CHECK  Be sure to check the generator on a level surface with the engine stopped.1. Check the engine oil level.  Using non detergent oil or 2 cycle engine oil could shorten the engine's detergent, premium quality 4-stroke engine oil, certified to meet or exceed U.S. automobile manufacturer's requirements for API Service Classification SG/SF. Select the appropriate viscosity for the average temperature in your area.40 should be an acceptable oil for most climates.  use synthetic oil or semi-synthetic oil, use only petroleum based oil in your generator engine. The reasons for this are many, but may include: not allowing the roperly “break-in” when new, excessive oil use, oil burning, fouled spark plugs,  etc.  Engine  issues  that  are  caused  by  the  use  of  synthetic  oil  may  not  be covered under the warranty. SAE Viscosity Grades  AMBIENT TEMPERATURE  Single Viscosity Multi- viscosity  Be sure to check the generator on a level surface with the engine stopped.  Using non detergent oil or 2 cycle engine oil could shorten the engine's service life. stroke engine oil, certified to meet or exceed U.S. automobile manufacturer's requirements for API Service Classification SG/SF. area. A 10W – 30 synthetic oil, use only petroleum based oil in your generator engine. The reasons for this are many, but may include: not allowing the in” when new, excessive oil use, oil burning, fouled spark plugs,  etc.  Engine  issues  that  are  caused  by  the  use  of  synthetic  oil  may  not  be
11 Loosen the cover screw and remove the left side maintenance cover. Remove the oil filler cap, and wipe the dipstick with a clean rag. Check the oil level by inserting the dipstick in the filler hole without screwing it in. If the oil level is below the end of the dipstick, refill the recommended oil up to the top of the oil filler neck.    ■    Running the engine with insufficient oil can cause serious engine damage.  NOTE: The Low Oil Alarm System will automatically stop the engine before the oil level  falls  below  the  safe  limit.  However,  to  avoid  the  inconvenience  of  an unexpected  shutdown,  it  is  still  advisable  to  visually  inspect  the  oil  level  before operation. You must screw down the dipstick completely to measure the oil level.             2. Check the fuel level. Use automotive unleaded regular gasoline only with an octane level no higher than 87 and with no more than 10 % ethanol. A fuel preservative and stabilizer should be added to any container of stored fuel. If the fuel level is low, refill the fuel tank until the level reaches the specified mark. Never use an oil/gasoline mixture or dirty gasoline. Avoid getting dirt, dust or water in the fuel tank. After refueling, tighten the fuel filler cap securely.   Oil gauge Oil FILLER HOLE UPPER LEVEL UPPER LEVEL UPPER LEVEL
12    ■  Gasoline is extremely flammable and is explosive under certain conditions. ■  Refuel  in  a  well-ventilated  area  with  the  engine  stopped.  Keep  all  smoking materials, sparks, and any other source of combustion away from the generator during refueling. ■  Do not overfill the fuel tank (there should be no fuel above the upper limit mark). After refueling, make sure the tank cap is closed properly and securely. ■  Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may ignite, If any fuel is spilled, make sure the area is dry before starting the engine. ■  Avoid repeated or prolonged contact with skin or breathing of vapor. KEEP OUT OF REACH OF CHILDREN.   Gasoline containing alternate fuels If you decide to use a gasoline containing ethanol, be sure its octane rating is no lower than the specification. Do not use a blend that contains more than 10% ethanol. Do not use gasoline containing methanol.    ■  Fuel system damage or engine performance problems resulting from the use of fuels that contain an improper alcohol blend are not covered under warranty.   ■  Before  buying  fuel  from  an  unfamiliar  station,  Determine  if  the  fuel  contains ethanol and if it does, confirm the type and percentage of ethanol used. If you notice any undesirable operating symptoms while using a gasoline that contains ethanol, or one that you think contains ethanol, replace it by a gasoline that you
13 know has the proper blend. 3. Check the air cleaner Check the air cleaner element to be sure it is clean and in good condition. Loosen the cover screw and remove the left side maintenance cover. Press the latch tab on the top of the air cleaner body, remove the air cleaner cover, check the element. Clean or replace the element if necessary. Picture of foam air filter cleaning process needed here.   ■  Never run the engine without the air cleaner. Rapid engine wear will result from contaminants, such as dust and dirt, being drawn through the carburetor, into the engine.
14 5. STARTING THE ENGINE  Before starting the engine, disconnect any load from the AC receptacle.  1. Turn the engine switch to the ON position.               2. Move the choke lever to the START position. NOTE: Do not use the choke when the engine is warm or the ambient air temperature is high.          3. Pull the starter grip until resistance is felt then pull the starter grip briskly toward the arrow as shown below.    CHOKE LEVER START START ON OFF ON ENGINE SWITCH
15   ■    Do not allow the starter grip to snap back. Return it slowly by hand.    4. Move the choke lever to the RUN position after the engine warms up.            ■  If the engine stops and will not restart, check the engine oil level before further troubleshooting.      CHOKE LEVER RUN RUN
16 6. GENERATOR USE  Be sure to ground the generator when loads are connected.    ■  To  prevent  electrical  shock  from  faulty  appliances,  the  generator  should  be grounded.  Connect  a  length  of  heavy  cable  between  the  generator's  ground terminal and an external ground source. ■  Connections for standby power to a building's electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Improper connections can allow electrical current from the generator to back feed into the utility lines. Such back feed may electrocute utility company workers  or  others  who  contact  the  lines  during  a  power  outage. When utility power  is  restored  the  generator  may  explode,  burn,  or  cause  fires  in  the building's electrical system. ■  Do not connect the generator to an automatic transfer device. Severe damage to the inverter module may result.
17  ■  The total wattage of all appliances connected must be considered. ■    Do not exceed the current limit specified for any one receptacle. ■  Do not connect the generator to a household circuit. This could cause damage to the generator or to electrical appliances in the house. ■  Do not modify or use the generator for other purpose than it is intended for. Also observe the following when using the generator. ■  Do not connect an extension to exhaust pipe. ■  When an extension cable is required, be sure to use a rubber sheathed flexible cable (IEC 245 or equivalent). ■  Only use an extension cord that meets these specifications: 12 gauge no more than 100 feet. ■  Keep the generator away from other electric cables or wires such as commercial power supply lines.      ■  The DC receptacle can be used while the AC power is in use. If you use both at the same time, be sure not to exceed the total power for AC and DC. ■  Most appliance motors require more than their rated wattage for start-up. Motor start up can be as much as 50% higher of the rated amperage found on the UL tag. Kipor  recommends  that  this  value  be  calculated  into  the  overall  amperage requirements of the customer.  AC application 1. Start the engine and make sure only the output indicator light (green) comes on. 2. Confirm that the appliance to be used is switched off, and plug in the appliance.
18   ■  Substantial overloading that continuously lights the overload indicator light (red) may  damage  the  generator.  Marginal  overloading  that  temporarily  lights  the overload indicator light (red) may shorten the service life of the generator. ■  Be sure that all appliances are in good working order before connecting them to the generator. If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn off the generator engine switch immediately. Disconnect the appliance and examine it for signs of malfunction. 3.  In  order  to  insure  the  optimum  output  and  the  maximum  service  life  of  the generator, the generator should run at a 50% load for the first 20 hours.  Output and Overload Indicators   The output indicator light (green) will remain on during normal operating conditions. If the generator is overloaded or if there is a short in the connected appliance, the output  indicator  light  (green)  will  go  out,  the  overload  indicator  light  (red)  will illuminate and current to the connected appliance will be shut off.  Stop the engine if the overload indicator  light (red) comes on and  investigate  the overload source ■  Before connecting an appliance to the generator, check that it is in good order and that its electrical rating does not exceed that of the generator. Connect the power cord of the appliance and start the engine.
19   ■  When an electric motor is started, both the overload indicator light (red) and the output  indicator light  (green) may go  on  simultaneously. This is normal  if  the overload indicator light (red) goes off after about four (4) seconds. If the overload indicator light (red) stays on, consult your generator dealer.  Overload Reset Switch Should  the  generator  overload,  AC  power  will  be  cut  off  but  the  engine  will  stay running. Correct the overload condition and then press the overload reset switch on the front panel. AC power will be restored immediately.    DC Operation The DC receptacle may be used for charging 12 volt automotive style batteries only, the no load voltage is 15V-30V.      ■ In DC operation, turn the Smart-throttle switch to the OFF position.  Connect the charging cables to the DC receptacle of the generator and then to the battery terminals.
20     ■  To  prevent  the  possibility  of  creating  a  spark  near  the  battery,  connect  the charging cable first to the generator then to the battery. Disconnect the cable first at the battery. ■  Before  connecting  charging  cables  to  a  battery  that  is  installed  in  a  vehicle, disconnect the vehicle’s ground battery cable. Reconnect the vehicle's ground battery cable after the charging cables are removed. This procedure will prevent the  possibility  of  a  short  circuit  and  sparks  if  you  make  accidental  contact between a battery terminal and the vehicle's frame or body.    ■  Do not attempt to start an automobile engine with the generator still connected to the battery. The generator may be damaged. ■  Connect  the  positive  battery  terminal  to  the  positive  charging  cord.  Do  not reverse the charging cables, or serious damage to the generator and/or battery may occur.    ■  The battery gives off explosive gases; keep spark, flames and cigarettes away. Provide adequate ventilation when charging.
21 ■  The battery contains sulfuric acid (electrolyte). Contact with skin or eyes may cause severe burns. Wear protective clothing and a face shield.   -If electrolyte gets on your skin, flush with water. -If electrolyte gets in your eyes, flush with water for at least 15 minutes and call a physician. ■  Electrolyte is poisonous. -If  swallowed,  drink  large  quantities  of  water  or  milk  and  follow  with  milk  of magnesia or vegetable oil and call a physician. ■  KEEP OUT OF REACH OF CHILDREN.  2. Start the engine    ■ The DC receptacle may be used while the AC power is in use. ■ An overloaded DC circuit will trip the DC circuit fuse. The fuse must be replaced before the DC receptacle is operative.    Replace the fuse with one of the same size and rating (5A). Exceeding the current rating may lead to alternator damage.
22 Low oil alarm system The  low  oil  alarm  system  is  designed  to  prevent  engine  damage  caused  by  an insufficient amount of oil in the crankcase. Before the oil level in the crankcase falls below a safe limit, the low oil alarm system will automatically shut down the engine (the engine switch will remain in the ON position).  If the low oil alarm system shuts down the engine, the low oil alarm indicator light (red) will come on when you operate the starter and the engine will not run. If this occurs add engine oil.    Air Conditioning Operation When running in parallel (see section 8) the combination of an IG2000i model can start and run most 13,500 BTU Air conditioners. An IG2000i models will start and run most 15000 BTU units. For best results, the SMART throttle switches should be in the  off  position.  Bring  the  generators  to  normal  operating  temperatures  before applying  the  air  conditioning  load.  Always  allow  a  2  minute  wait  period  when manually cycling an air conditioner off and on.    A longer wait period may be required under unusually hot weather conditions. Additionally, all other loads should be turned off until the air conditioner has started and is performing normally. It is also important to follow the air conditioner manufacturer's instructions for starting and restarting for proper  operation.    Some  air  conditioner  manufacturers  offer  a  start  capacitor  or rapid start kit as an extra cost option. The lack of a start capacitor can cause the air conditioner to draw too high a starting current and overload the generators. Contact your  air  conditioner  dealer  if  you  consistently  have  problems  starting  your  air conditioner with the generators in parallel.
23 Smart Throttle System When the smart throttle switch is placed in the on position, engine speed is kept at idle automatically when the electrical load is disconnected and returns to the proper speed to match the power of the electrical load when the load is reconnected. This position is recommended to minimize fuel consumption while in operation. If  running  the  generator  at  full  output,  turn  the  smart  throttle  switch  to  the  “off” position.    ■  The Smart throttle system does not operate effectively if the electrical appliance requires constant fluctuations in power. ■  When high electrical loads are connected simultaneously, turn the Smart throttle switch to the OFF position to reduce voltage fluctuation or shutdown. ■  In DC operation, turn the Smart throttle switch to the OFF position.   OFF: Smart throttle system does not operate. Engine speed varies with the load.
24 High altitude operation At higher altitudes, the standard carburetor air-fuel mixture will be excessively rich. Performance will decrease,  and fuel  consumption will  increase.  Power output  will decrease 3.5% for each 1000 feet (305 meters) above sea level. High altitude performance can be improved by installing a smaller diameter main fuel jet  in the carburetor.  If  you always operate  the  generator  at  altitudes higher  than 5000 feet or 1500 meters above sea level, have your authorized dealer install a high altitude main jet. Even with suitable carburetor jetting, engine horsepower will decrease approximately 3.5% for each 1000 feet or 305 meter increase in altitude. The affect of altitude on the horsepower will be greater than this if no carburetor modification is made.    ■  Operation of the generator at an altitude lower than the carburetor is jetted for may  result  in  reduced  performance,  overheating,  and  serious  engine  damage caused by an excessively lean air/fuel mixture. ■  Be sure to have any modification reversed at lower altitudes.  Temperature High temperature adversely affects generator operation. Generator performance will decrease 1% for each 10°F (5.5°C) increase in tempe rature above 85°F (29°C) The normal operating range of this generator is -20° to  113° F (-29° to 45°C)    ■    Do  not  operate  the  generator  when  the  ambient  temperature  is  below  -20°F (-29°C) ■  Do  not  operate  the  generator  when  the  ambient  temperature  exceeds  113°F (45°C)
25  7. STOPPING THE ENGINE  To stop the engine in an emergency, turn the engine switch to the OFF position.  IN NORMAL USE: 1. Switch off the connected equipment and pull the inserted plug out.    2. Turn the engine switch to the OFF position
26
27 Optional Remote stop: Shut off the connected equipment, press stop button, the genset will be stopped. The max. remote control distance:65feet.     Stop button    Remote control key
8. Operating two generators in parallel    Two generators run in parallelTwo IG2000i digital generators running in parallel can increase the output power of generators.                                                                                                            28 wo generators in parallel Two generators run in parallel generators running in parallel can increase the output power of                                                                                                               Figure 1 Figure 1
29 Procedures to run 2 generators with a parallel box: 1. Prepare two KIPOR IG2000 I digital generators.  Figure 2 Note: Be sure the two generators are shut off.  2.  Insert  the  connecting  plug  ②  of  the  parallel  cable  ①  to  PARALLEL  OUTPUT receptacle  ③  on the controller panel of each generatorSee figure 3 3. Connect the grounding terminal  ④  of the parallel cable to the grounding terminal ⑤  of each generatorSee figure 3   Figure 3     Be sure all the electrical equipment is grounded. See  .   Be sure each generator is on a stable level surface.  4. Start the two generators: The start procedure is the same as normal start procedure. (Refer to the section introducing how to start the engine in this manual)
30      Before  starting,  make  sure  that  the  PARALLEL  OUTPUT  on  each  controller panel  has  been  inserted  to  the  parallel  cable.  Otherwise,  damage  to  the generator may occur.  5. Insert the electrical equipment plug    into the parallel cable receptacle      and turn the power switch of the electrical equipment to the on position. (See figure 4   Figure 4      The  power  of  electrical  equipment  shall  not  exceed  the  rated  output  of  the parallel receptacle.   The  parallel receptacles  used in different area are  different. Refer  to  Parallel receptacle usage manual.
31 Shut off the generator: 1.  Turn  off the  power switch of the electrical  equipment; pull  the plug  out of  the parallel receptacle. 2.  Shut off the two generators. 3.  If  two  generators  parallel  are  not  used,  be  sure  to  remove  the  cable  from PARALLEL OUTPUT.      Kipor IG2000i parallel cable is only suitable for two KIPOR IG2000i generators being run simultaneously.     Always use Kipor parallel output cable on IG2000i.   When using the parallel cable, safely insert the plug into the receptacle.     When  running  two  generators  in  parallel,  DO  USE  the  receptacle  of  parallel cable for power output, Do not use the receptacle on the control panel.   Before  starting  the  generator,  connect  the  parallel  output  cable,  after  the generators  stopped,  disconnect  the  parallel  output  cable.  Never  connect  or disconnect the parallel output cable when the generators are running.   If the parallel output cable is still connected when one generator has stopped running, stop the running generator and remove the parallel box.     If  only  one  generator  is  operated,  make  sure  the  parallel  output  cable  is disconnected.   When the two generators are running separately, make sure the parallel output cable is disconnected.   Before operating the generator, read the manual carefully.
32 9. MAINTENANCE  The purpose of the maintenance and adjustment schedule is to keep the generator in the best operating condition. Inspect or service as scheduled in the table below.    ■  Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated. The exhaust contains poisonous carbon monoxide gas.      Use genuine our parts or their equivalent. The use of replacement parts which are not of equivalent quality may damage the generator.   When repairing or replacing the accessories of emission control system, make sure to use the EPA standard accessories.  Emission control system  Emission source Exhaust gas contains carbon monoxide, nitrous oxide (NOx), and hydrocarbons. It is very important to control the emissions of NOX and hydrocarbons as they are a major contributor to air pollution. Carbon monoxide is a poisonous gas. The emission of fuel vapors is a source of pollution as well. The Kipor generator engine utilizes a precise air-fuel ratio and emission control system to reduce the emissions of carbon monoxide, NOX, hydrocarbons, and evaporative fuel emissions.    Regulation Your engine has been designed to meet current Environmental Protection Agency (EPA)  and  the  California  Air  Resources  Board  (CARB)  clean  air  standards  if  so equipped  and  designated.  The  regulations  dictate  that  the  manufacturer  provide operation and maintenance standards regarding the emission control system. Tune up specifications are provided in the Specifications section and a description of the emission control system may be found in an appendix to this manual, Adherence to
33 the  following  instructions  will  ensure  your  engine  meets  the  emission  control standards.   Modification Modification  of  the  emission  control  system  may  lead  to  increased  emissions. Modification is defined as the following:   Disassemble  or  modify  the  function  or  parts  of  the  intake,  fuel  or exhaust system.   Modify or destroy the speed governing function of the generator.    Engine faults that may affect emission Any  of  the  following  faults  must  be  repaired  immediately.  Consult  with  your authorized Kipor service center for diagnosis and repair:   Hard starting or shut down after starting   Unstable idle speed   Shut down or backfire after applying an electrical load   Backfire.   Black smoke and/or excessive fuel consumption    Replacement parts and accessories The parts making up the emission control system applied to Kipor engine have been specifically  approved  and  certified  by  the  regulatory  agencies.  You  can  trust  the replacement  parts  supplied  by  Kipor  have  been  manufactured  to  the  same production  standard  as  the  original  parts.  The  use  of  replacement  parts  or accessories  which  are  not  designed  by  Kipor  may  affect  the  engine  emission performance.  The  manufacturers  of  replacement  parts  and  accessories  have  the responsibility to guarantee that their replacement products will not adversely affect emission performance.  Maintenance   Maintain  the  generator  according  to  the  maintenance  schedule  in  this  section. Service items more frequently when used in dusty areas, or under conditions of high load, temperature, and humidity.    Air Quality Index (only for California certified models) CARB requires that an air quality index label be attached to every certified engine showing the engine emission information for the emission duration period. The label is provided for the user to compare the emission performance of different engines.
34 The lower the air index, the better the engine emission performance. The description of durability is helpful for the user to learn the engine emission duration period and the  service  life  of  emission  control  system.  Refer  to  the  warranty  section  of  this owner’s manual for more information.       The air quality index label is designed to be permanently affixed to the generator and removal should not be attempted.    Maintenance Schedule REGULAR SERVICE PERIOD(1) EACH USE FIRST MONTH OR 20HRS EVERY 3 MONTHS OR 50HRS EVERY 6 MONTHS OR 100 HRS EVERY YEAR OR 200 HRS ITEM Perform at every indicated month or operating hour interval, which- ever comes first. Engine oil  Check level  ○         Change    ○    ○   Air cleaner  Check  ○         Clean      ○(1)     Spark plug  Clean-adjust       ○   Replace          ○ Combustion chamber Clean  ○ Every 300Hrs. (2) Valve clearance  Clean-adjust         ○(2) Fuel tank and filter  Clean        ○(2)   Fuel lines  Check  Every 2 years (Replace if necessary) (2) NOTE:    (1)  Service more frequently when used in dusty areas. (2)  These items should be serviced by your servicing dealer unless you have the proper tools and are mechanically proficient. Refer to the shop manual for service procedures. (3)   For  commercial  use,  log  hours  of  operation  to  determine  proper maintenance intervals.
35  1. CHANGING OIL Drain the oil while the engine is still warm to assure rapid and complete draining.   ■    Make  sure  to  turn the  engine  switch  and  the  fuel  cap  vent  lever  OFF  before draining.  1. Loosen the cover screw and remove the left side maintenance cover. 2. Remove the oil filler cap. 3.  Drain  dirty  oil  into  a  container  thoroughly.  See  note  below  concerning  proper disposal. 4. Refill with the recommended oil, and check the oil level. 5. Reinstall the left side maintenance cover and tighten the cover screw securely.  Engine oil capacity: 0.42 qt. (0.4L)     ■  Please  dispose  of  used  motor  oil  in  a  manner  that  is  compatible  with  the environment and local disposal regulations. Do not throw it in the trash or pour it on the ground.
36  2. AIR CLEANER SERVICE IG2000i A  dirty  air  cleaner  will  restrict  air  flow  to  the  carburetor.  To  prevent  carburetor malfunctioning,  service  the  air  cleaner  regularly.  Service  more  frequently  when operating the generator in extremely dirty areas.    ■Do not use gasoline or low flash point solvents for cleaning. They are flammable and explosive under certain conditions.    ■Never run the generator without the air cleaner, otherwise rapid engine wear may result.  1. Loosen the cover screw and remove the left side maintenance cover. 2. Remove the air cleaner cover and remove the fine and filter coarse elements. 3. Wash the filter elements in a non-flammable or high flash point solvent and dry it thoroughly. 4. Soak the filter elements in clean engine oil and squeeze out the excess oil. 5. Reinstall the coarse and fine air cleaner filter elements and the air cleaner cover. Tighten the cover screw securely. 6. Reinstall the maintenance cover and tighten the cover screw securely.
37 3. SPARK PLUG MAINTENANCE To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. 1. Remove the spark plug maintenance cover.    2. Remove the spark plug cap. 3. Clean any dirt from around the spark plug base. 4. Use the wrench provided to remove the spark plug    5. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean the spark plug with a wire brush if it is to be reused. 6. Measure the plug gap with a feeler gauge. The gap should be 0.024-0.028in (0.6-0.7mm). Correct as necessary by carefully bending the side electrode.
38   7. Install the spark plug carefully, by hand, to avoid cross-threading. 8. After a new spark plug has been seated by hand, it should be tightened 1/2 turn with a wrench to compress its washer. If a used plug is being reinstalled, it should only require 1/8 to 1/4 turn after being seated. 9. Reinstall the spark plug cap on the spark plug securely. 10. Reinstall the spark plug maintenance cover.   ■The  spark  plug  must  be  securely  tightened.  An improperly  tightened  plug  can  become  very  hot  and possibly damage the generator. ■Never use a spark plug with an improper heat range.
39 10. TRANSPORTING and STORAGE  To  prevent  fuel  spillage  when  transporting  or  during  temporary  storage,  the generator should be secured upright in its normal operating position with the engine switch placed in the OFF position. When transporting the generator:    ■  If you must transport the generator in a vehicle, drain all fuel from the generator. ■  Do not operate the generator while it is on or in a vehicle. Take the generator out of the vehicle and use it in a well ventilated area. ■  Avoid a storage area exposed to direct sunlight when putting the generator on a vehicle.  If  the  generator  is  left  in  an  enclosed  vehicle  for  many  hours,  high temperature inside the vehicle could cause residual fuel to vaporize resulting in a possible explosion. ■  Do  not  drive  on  a  rough  road  for  an  extended  period  with  the  generator  on board.      Before storing the unit for an extended period: 1. Be sure the storage area is free of excessive humidity and dust. 2. Drain the fuel.    ■  Gasoline is extremely flammable and explosive under certain conditions. ■  Do not smoke or allow flames or sparks in the area.
40  Periodic running of the Generator It  is  essential  that  the  generator  be  periodically  run  on  a  regular  basis.  This  will prevent the accumulation of varnish or sludge in the fuel system and also remove moisture  from  the  generator  windings.  Additionally  the  engine  seals  and  moving components are lubricated. Periodically running the generator at least at 1/2 the load for 60 minutes  each month. Gasoline fuel treatments to  prevent  contamination of your  fuel  supply  are  available  from  your  dealer.  Fuel  varnishing  necessitating replacement of the carburetor is not a warrantable failure.  Storage a.  Drain all gasoline from the fuel tank into an approved gasoline container. b.  Turn the engine switch ON, and loosen the carburetor drain screw and drain the gasoline from the carburetor into a suitable container. Dispose of properly. c.  With the drain screw loosened remove the spark plug cap and pull the starter grip 3 to 4 times to drain the gasoline from the fuel pump. d.  Turn the engine switch to the OFF position, and tighten the drain screw securely. e.  Reinstall the spark plug cap on the spark plug securely. f.  Change the engine oil. g.  Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder.  Crank  the  engine  several  revolutions  to  distribute  the  oil  and  then reinstall the spark plug. 5.  Slowly  pull  the  starter  grip  until  resistance  is  felt.  At  this  point,  the  piston  is coming up on its compression stroke and both the intake and exhaust valves are closed.  Storing  the  engine  in  this  position  will  help  to  protect  it  from  internal corrosion.
41  11. TROUBLESHOOTING  Engine will not start:               To check:1) Remove the spark plug cap and clean any dirt from around the spark plug.2) Remove the spark plug and install the spark plug in the plug cap.3) Set the plug side electrode on the cylinder head to ground.4) Pull the recoil starter, sparks should jump across the gap.Is there fuel in the tank?   NO Refuel the fuel tankYES Is the engine switch on? Turn the engine switch on. Is the enough oil in the engine?Add the recommended oil.Is there a spark from  the spark plug?Replace the spark plug.Still no spark YES YES NONONO  Be sure there is no spilled   fuel around the spark plug.       Spilled fuel may ignite. WARNING If    the    engine    still    does notstart, take the generator to an authorized dealer.
42         Appliance does not operate:               Is the output indicator light ON?Is  the  overload  indicator  light on?  Take the generator to anauthorized dealer.  Check the electrical appliance or equipment for any defects.Take the generator to an authorized dealer. Replace the  appliance or equipmentTake the electrical appli- ance or equipment to an electrical shop for repairStop and restart the engine.YESDEFECTSNO DEFECTSNONOYESYESReplace the fuse
43  No electricity at the DC receptacle:    Take the generator to anauthorized dealer. Is the DC circuit fuse blown?NO
44 12. SPECIFICATIONS  Genset model  IG2000i Rated frequencyHz  60 Rated voltageV  120 Rated currentA  13.3 Rated speedr/min  4500 Rated output powerkVA 1.6 Max. output powerkVA  2.0  DC output DC output  12V-5.0A Fuse  Equipped No. of phases  Single phase  Engine Engine model  KG158 Engine structure  Single cylinder, air-cooled, 4-stroke, in-line arrangement, OHV, gasoline engine Displacementbore × stroke  105ml58×40 mm Compression ratio  8.5:1 Rated frequency [kW/(r/min)]  2.2/4500 Rated speedrpm  4500 Ignition system  Transistor electrical ignition Spark plug  UR5/A7RTC Start mode  Recoil start Fuel type  Automotive unleaded gasoline Fuel consumptiong/Kw.h  420 Lube oil type  SAE 10W30 (above CCgrade)  Capacity of fuel tankL  3.7 Running lasting timehrsunder rated output power 3.5 Noized BA/at 7m0-load~full-load 61-73     Dimension (L×W×H[(mm)]  530×310×430 Net weight [kg]  23 *The  declared values shall consider  uncertainties  due to  production variation and measurement procedures.
45 13. WIRING DIAGRAM  IG2000i Wiring Diagram
46 14. WARRANTY  Kipor Power Equipment, Inc. Warranty Product registration: Registration is required for warranty coverage, register your product by completing the registration form found with the owner’s manual or go to www.kiporpowerequipment.com  LENGTH OF WARRANTY Kipor Products are covered by this warranty from the date of original retail purchase for a period of three (3) years or 300 hours for residential use and for one (1) year or 300 hours for commercial and rental applications. If batteries are shipped with generators, they are warranted by the manufacturer.    The warranty coverage is continual from the original date of purchase, and does not restart upon the replacement of any part or complete unit. Individual parts replaced at any point during the warranty period are only eligible for warranty coverage for the balance of the original warranty period and owner.  ELIGIBILITY To be eligible for warranty service, the product must be purchased in the United States or Canada from an authorized dealer. This warranty applies to the original retail purchaser only  and  is  not  transferable.    Proof  of  purchase  is  required.    Goods  exported  from North America as well as goods sold at auction are excluded from warranty coverage. Warranty coverage will only be provided by authorized dealers in the United States and Canada.    COVERAGE Parts and labor will be covered for any failure that is proven to be a failure of material or workmanship under normal use during the applicable warranty time period. It is the responsibility of the end user to return the product to the nearest authorized repair center as directed by the warranty administration center. In the event that the generator is deemed not repairable or the necessary repair would be economically unfeasible, the Kipor distributor will pay for shipping of the unit from the repair center to the designated distributor facility and the shipping of a replacement unit. Kipor or its distributor reserves the right to repair or replace these parts at its option.    The return of defective parts may be requested. Anything replaced under warranty becomes the property of Kipor.    TO OBTAIN WARRANTY SERVICE Contact any authorized dealer or contact our national customer service center at: Phone: 888-645-0197            E-mail: service@kiporpowerequipment.com If contacting us by e-mail, be sure to include a description of the problem as well as all return contact information such as address, phone number, fax number, e-mail, etc.
47 Engine serial number and proof of purchase are required.      EXCLUSIONS This warranty does not extend to parts affected or damaged by accident and/or collision, normal  wear,  fuel  contamination  or  degradation,  use  in  an  application  for  which  the product  was  not  designed  or  any  other  misuse,  neglect,  incorporation  or  use  of unsuitable  attachments  or  parts,  unauthorized  alteration,  or  any  causes  other  than defects  in  material  or  workmanship.  This  warranty  does  not  extend  to  normal maintenance items such as belts, hoses, spark plugs and filters past the first scheduled replacement or service interval for these items, whichever comes first. Kipor will pay for minor adjustments for a period of ninety days from the purchase date of the generator.    DISCLAIMER  OF  CONSEQUENTIAL  DAMAGE  AND  LIMITATION  OF  IMPLIED WARRANTIES Kipor  denies  any  responsibility for  loss  of  time  or  use  of  the  product,  transportation, commercial  loss,  or  any  other  incidental  or  consequential  damage.  Any  implied warranties are limited to the duration of this written limited warranty.    Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages.    Therefore, the above exclusions and limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.   Emission Control System Warranty  In the United States and California, new small off-road engines must be designed, built and equipped to meet stringent emission standards. Kipor must warrant the emission control system on your generator engine for the periods of time listed below provided there has been no abuse, neglect, improper maintenance, or unauthorized application of your small off-road engine.  If a warrantable condition is determined, Kipor Power Equipment will repair your small off-road engine at no cost to you including diagnosis, parts, and labor. Coverage Emissions control parts on the engine are warranted for a period of two years, subject to provisions set below. If any covered part on your engine is defective, the part will be repaired or replaced by Kipor Power Equipment.  Owner’s Responsibilities You are responsible to maintain the engine as defined in your Kipor Generator Owner’s Manual. Kipor recommends that you retain all record/receipts covering maintenance on
48 your engine, but Kipor Power Equipment cannot deny warranty claims based on a lack of receipts or for your failure to perform all scheduled maintenance. You may be denied warranty coverage if a part has failed due to abuse, neglect, improper maintenance, or unapproved applications.  You are  required  to  bring  your  generator  to an  authorized Kipor  generator dealer  for repairs  as  soon  as  a  problem  exists.  For  emissions  warranty  service,  contact  your nearest  dealer.  For  a  listing  visit  www.kiporpowerequipment.com  or  by  calling 888-645-0197.  Emission Control System Parts Coverage under this warranty extends only to the emissions control parts listed below:  1. Fuel System         A. Carburetor gaskets         B. Fuel lines, fittings, and clamps         C. Fuel filter (if equipped)         D. Fuel pump (if equipped)         E. Carburetor 2. Intake System         A. Air cleaner assembly         B. Intake manifold 3. Ignition System         A. Ignition coil         B. Spark plug 4. Exhaust System         A. Catalytic converter (if equipped)         B. Exhaust manifold         C. Gaskets 5. Crankcase Breather System         A. Breather assembly         B. Breather tube 6.    Air Injection System         A. Secondary air injection valve 7. Fuel Tank Evaporative Emissions Control System         A. Fuel tank         B. Fuel cap         C. Carbon canister and brackets 8. Miscellaneous Items used in above         A. Hoses, connectors, and fittings         B. Electrical switches Warranty Provisions
49  1. Claims Warranty claims shall be filed in accordance with the provisions of the Kipor warranty and policies established with the authorized repair center network. 2. Exclusions Warranty  coverage  shall  be denied for  failure  of an  emissions  control system  part  caused  by  abuse,  neglect,  improper  maintenance  or  application  as described in the Kipor Generator Owner’s Manual. Additionally, coverage may be denied for the use of add-on parts, modified parts, or parts that are not equivalent to original Kipor generator parts in performance and durability. 3. Length of Coverage Kipor Power Equipment warrants to the original retail purchaser and each subsequent owner that the emissions control system shall be free of defects in materials and workmanship for a period of two years from the date of the original retail customer. 4. Repair or Replacement Cost Repair or replacement of any emissions control system part will be repaired at no charge to the owner including diagnostic labor which would determine an  emissions control  system  defect  exists  if  the  repair  is  performed at  an authorized Kipor repair service center. 5. Consequential Damage Repairs will extend to any other engine part damaged by the failure of any emission control system part. 6. Maintenance The emissions control system and associated parts are warranted for defects during the warranty period only. The warranty does not cover any replacement of parts that are replaced as required by the maintenance schedule in the Kipor Generator Owner’s Manual. Any replacement part that is equivalent in function and durability may be used for maintenance or repairs.   Questions If you have any questions regarding your rights and responsibilities under this emissions system warranty, you may contact Kipor Aftermarket Support Service Center.  By email: service@kiporpowerequipment.com By phone: 888-645-0197 By mail: Kipor Power Equipment, 13009 SE Jennifer St. #105 Clackamas, OR    97015
50 Intake System and Carburetor   Exhaust System
51 Fuel System              Gas Cap Washer Sleeve Bushing Gasket Washer Cotter Pin Retention Hook Fuel Indicator Strainer      Gas Cap Sleeve Vent Hose Fuel Tank Cover Fuel Tank Certification No.