XAC Automation FD400-8790 Portable Terminal User Manual InstallationGuide FD400 with charger 0A 101609

XAC Automation Corporation Portable Terminal InstallationGuide FD400 with charger 0A 101609

User Manual

                   First Data Corporation   c/o Tasq Technology 800-835-3362 Ext. 0 http://www.firstdata.com/  Printed in the United States of America. © Copyright 2006 First Data Corporation. All rights reserved.  " Federal Communications Commission (FCC) Statement “ This Equipment has been tested and found to comply with the limits for a  Class  A  digital device, pursuant  to  part  15  of  the  FCC  Rules. These limits  are  designed  to  provide  reasonable  protection  against  harmful interference  when  the  equipment  is  operated  in  a  commercial environment. This equipment generates, uses, and can    radiate  radio frequency energy and, if not installed and used in accordance with the instruction  manual,  may  cause  harmful  interference  to  radio communications. Operation  of  this  equipment  in  a  residential  area  is  likely  to  cause harmful interference in which case  the user  will be  required to  correct the interference at his own expense.     © 2009 First Data Corporation.    PORTABLE TERMINAL  FD-400 INSTALLATION GUIDE
               1. POWER ON TERMINAL There  are  two  holes  under  a  plastic  cover  on  the  right side of terminal (Figure 1). One  is  power  input;  another  is  a  port  for  devices connected to terminal (Figure 2).     (Adapter:  LI  SHIN  INT.  /  LSE0107A1240:  Input: 100-240Vac, 50/60Hz 1A; Output: 12Vdc, 3.33A) (Car Charger: EDAC POWER ELECTRONICS CO., LTD./ED1025: Input : 11-16Vdc, 5A. Output: 12Vdc, 2.5A) “Caution:  For  continued  protection  against fire,  replace only  with  same  type  same  rating  fuse.”  Marking  is located  on  the  enclosure  of  cigarette  lighter  plug  or located  on  the  input  cable  near  cigarette  lighter  plug. Fuse  rating  (voltage  and  ampere)  shall  also  marked  on the enclosure of cigarette lighter plug near the fuse. Rechargeable  battery  is  on  the  back  side  of  terminal (Figure 3). (Battery pack: Cheng Uei/FD-400 7.4V, 2.3Ah) After plugged power cord or installed the battery, press the power button on the front to power on it (Figure 4).    Caution: Risk of explosion if the battery is replaced by an incorrect  type. Please dispose of used battery according to the instructions.  Environment: Operating Temperature: 0°C to 40°C Storage Temperature: - 20°C to 60°C    2. LOADING THE PAPER   Pop the printer cover’s latch to open the cover (Figure 5); then lift the cover.     Figure 1   Figure 2  Figure 3  Figure 4             Figure 5    Load a roll  of paper  (Appleton 1012 recommended) into the printer (Figure 6).   The  print-side  of  the  paper  will  feed  out  facing  the operator. Close the cover and tear off any excess paper (Figure 7).   The printer is now ready to use.  Caution:  For  body  worn  operation,  this  terminal  will keep away 20cm from the body in order to meet the FCC RF exposure guidelines  3. USING THE CARD READER Find the reader slot in the middle of surface. Swipe card through slot in left to right or the opposite direction with stripe face to us (Figure 8).    4. USING THE KEY PAD The  keypad  allows  you  to  select  transaction  types  and enter  information.  Its  16  keys  can  be  used  to  select numbers, letters, and to enter data (Figure 9). To enter numbers or letters, simply press the appropriate key.  For  example,  to  type  the  letter  A,  press  [ALPHA], then [A] (the Void key) (Figure 10)  Caution:   A shielded-type power cord is required in order to meet FCC  emission  limits  and  also  to  prevent  interference  to the  nearby  radio  and  television  reception.  It  is  essential that only the supplied power cord be used.   Use only shielded signal cables to connect I/O devices to this equipment.   You  are  cautioned  that  changes  or  modifications  not expressly  approved  by  the  party  responsible  for compliance  could  void  your  authority  to  operate  the equipment."    Figure 6  Figure 7      Figure 8     Figure 9    Figure 10
Federal Communications Commission NoticeThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:  (1) This device may not cause harmful interference, and(2) this device must accept any interference received, including interference that may cause undesired operation.  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee this equipment does not cause harmful interference to radio or TV reception. This can be determined by turning the equipment on and off. The user is encouraged to try to correct the interference by one or more of the following measures:  zReorient or relocate the receiving antenna.  zIncrease the separation between the equipment and receiver. zConnect the equipment into an outlet on a circuit different from that to which the receiver is connected. zConsult the dealer or an experienced radio or television technician for help.NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.   SUCH MODIFICATIONS COULD VOID THE USERS AUTHORITY TO OPERATE THE EQUIPMENT. FCC Radiation Exposure StatementThis  equipment  complies   with FCC  radiation  exposure  limits  set  forth  for  an uncontrolled  environment .  End  users  must  follow  the  specific  operating instructions for satisfying RF exposure compliance. To maintain compliance with FCC RF exposure compliance requirements, please follow operation instruction asdocumented in this manual.                                                                                                                                                            For hand-held or desktop operation only.  This PORTABLE TERMINAL  meets                                                                                                                                                             FCC RF exposure guidelines when used in hand-held or desktop operation.

Navigation menu