Xmark BTG Infant Tag User Manual 805U2401 Rev 01 indd

Xmark Corporation Infant Tag 805U2401 Rev 01 indd

Manual

Download: Xmark BTG Infant Tag User Manual 805U2401 Rev 01 indd
Mirror Download [FCC.gov]Xmark BTG Infant Tag User Manual 805U2401 Rev 01 indd
Document ID253412
Application IDucIs5pHmLupp3RDDtJTKRg==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize24.92kB (311521 bits)
Date Submitted2002-06-28 00:00:00
Date Available2002-06-28 00:00:00
Creation Date2002-06-24 08:47:15
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2002-06-24 08:47:15
Document Title805U2401 Rev 01.indd
Document CreatorPScript5.dll Version 5.2
Document Author: Steve

Instantel hereby disclaims all warranties,
express or implied, arising out of or in
connection with any of its Products of the
use or performance thereof, including but
not limited to, where allowable by law, all
other implied warranties or conditions of
merchantable quality and fitness for a particular purpose and those arising by statute
or otherwise in law or from a course of
dealing or usage of trade.
Instantel’s liability to you or anyone claiming through or on behalf of you with respect
to any claim or loss arising out of the use
or misuse of Instantel’s Product, defective
products or materials, improper installation or maintenance of Instantel’s Product
or products or the system in which they
are incorporated, or alleged to have resulted
from an act or omission of Instantel or any
person, negligent or otherwise, shall be
limited to:
Part Number 806A2401
Hugs Tag Instructions
false reports of infant abductions and/or
mother/infant mismatches.
© 2002 Instantel Inc. All Rights Reserved. Instantel and Hugs are registered trademarks of Instantel Inc. in
North America. Kisses, the hearts logo, Xmark and Heartbeat are trademarks of Instantel Inc. Xmark is a division
of Instantel Inc. Printed in Canada. June 2002. 806U2401 Rev A. Preliminary
Certified to the ISO 9001 Quality Standard
In no event shall Instantel be liable for
general, specific, indirect, consequential,
incidental, exemplary or punitive damages
or any losses or expenses suffered by you or
anyone else, whether or not Instantel, or
its employees, officers, agents, resellers or
installers has been informed of the risk of
such loss or expense and whether or not such
losses or expenses were foreseeable.
309 Legget Drive Kanata,
Ontario, Canada K2K 3A3, or
808 Commerce Park Drive
Ogdensburg, NY USA 13669
B) refund of the purchase price of the Product supplied by Instantel.
Telephone: 1-613-592-4642
Facsimile: 1-613-592-4296
Web Site: www.xmarksystems.com
A) the repair or replacement of defective
Product or materials supplied by Instantel
during the warranty period as set out in
the Product documentation; or, at the
option of Instantel,
Instructions for the Hugs Infant Tag
Introduction
The Hugs tag is part of the Hugs Infant
Protection System. The tag is attached
to the infant using a Hugs tamper-proof
strap. From the moment of attachment,
the infant is automatically enrolled in the
system, and protected against abduction.
Cutting the band or attempting to remove
the infant without authorization from the
protected area will immediately cause an
alarm.
The Hugs tag is also used with the Kisses
Mother/Infant Matching addition to the
Hugs System. Kisses is designed to confirm
that the correct infant is matched with the
correct mother each time they are brought
together. The Hugs tag emits an audible
beep to indicate either a correct or incorrect match.
The tag is reusable, and does not interfere
with other hospital or personal medical
equipment.
The patented asymmetrical shape of the
tag ensures that it does not pinch or irritate
the baby’s skin, and also helps prevent it
from being kicked off, while still allowing
the ankle joint to move freely.
The tag is water proof which allows bathing of the infant. It is also resistant to
soiling and UV light.
Please refer to the instructions included
with the Hugs straps for details on attaching the tag to an infant.
Note: The tag is not sterilized at the factory. You may wish to clean the tag prior
to first use.
Cleaning the Tag
The Hugs tag can be cleaned using a softbristle brush and a disinfectant soap or
similar solution with no more than 20%
alcohol content (for example, Butcher’s
Heptagon Disinfectant Cleaner, or KleenAseptic from Metrex Research Corp.). Dry
the tag thoroughly before use.
A small soft-bristle brush can be used to
clean the tag slots. Pass the brush carefully through the tag slot moving from the
bottom to top of the tag.
Notes:
• Do not use an autoclave to clean the tag
or serious damage may result.
• Do not soak the tag in alcohol or alcohol-based cleaners.
• Do not immerse the tag when cleaning.
Handling Information
Battery Handling - this device contains a
lithium battery. Do not force open, heat to
100° C, or dispose of in fire.
Canada—Industry Canada
The term “IC:” before the certification/
registration number only signifies that
Industry Canada technical specifications
were met.
Warranty
Xmark’s products are warranted against
defects in materials and workmanship and
shall perform in accordance with published specifications for a period of one
year. Xmark reserves the right to change
specifications without notice.
Limitation of Liability
X-Rays - Do not directly expose the tag
to X-rays. (The tag is not affected by stray
radiation.)
This Product has been designed for use to
assist in the prevention of infant abduction
and/or mother/infant mismatching.
Storage
The range, accuracy, function and performance of this Product may vary from
the published specifications due to many
factors, including, without limitation, site
impairments from structural effects, metal
objects in the vicinity, placement of the
receiver and transmitter, interference from
other electrical devices, atmospheric effects,
installation, and maintenance. There may
be other factors, which also affect performance of this Product.
Store Hugs tags at room temperature.
Statements
United States—Federal Communication
Commission (FCC)
This device complies with Part 15 of the
FCC Rules. Operation is subject to the
following two conditions: (1) this device
may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
NOTE: This equipment has been tested
and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate
radio frequency energy and, if not installed
and used in accordance with the instruction
manual, may cause harmful interference to
radio communications. Operation of this
equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Instantel does not guarantee that this Product will detect 100% of infant abductions
and/or mother/infant mismatches. Instantel does not guarantee that this Product will
not return false reports of infant abductions
and/or mother/infant mismatches.
Monthly testing and maintenance of this
Product, as described in the Product documentation, is essential to verify the system
is operating correctly and to ensure that the
probability of detecting an alarm and/or
locating the transmitter are maximized.
The failure to undertake regular testing and
maintenance will increase the risk of system
failure and failure to detect infant abductions and/or mother/infant mismatches.
The failure to undertake regular testing
and maintenance will increase the risk of

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2002:06:24 08:47:15-04:00
Modify Date                     : 2002:06:24 08:47:15-04:00
Page Count                      : 2
Creation Date                   : 2002:06:24 12:47:15Z
Mod Date                        : 2002:06:24 12:47:15Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : Steve
Metadata Date                   : 2002:06:24 12:47:15Z
Creator                         : Steve
Title                           : 805U2401 Rev 01.indd
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ISEBTG

Navigation menu