Xmark MTG Low Power Transmitter User Manual 806U2201 Rev A Kisses Users Sheet indd

Xmark Corporation Low Power Transmitter 806U2201 Rev A Kisses Users Sheet indd

Contents

Manual

Kisses Tag  Instructions309 Legget Drive Kanata, ON  K2K 3A3 Canada   or 808 Commerce Park Drive Ogdensburg, NY 13669 USA  Telephone: 1-613-592-4642  Facsimile:  1-613-592-4296  Web Site: www.xmarksystems.com© 2002 Instantel Inc. All Rights Reserved. Instantel and Hugs are registered trademarks of Instantel Inc. in North America. Kisses, the hearts logo and  Xmark and are trademarks of Instantel Inc. Xmark is a division of Instantel Inc. Printed in Canada. May 2002. 806U2201 Rev A.Certifi ed to the ISO 9001 Quality StandardPart Number 806A2201StatementsUnited States—Federal Communication Com-mission (FCC)This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions:  (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.NOTE:  This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.  This equipment gen-erates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.  Operation of this equip-ment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Canada—Industry CanadaThe term “IC:” before the certifi cation/registration number only signifi es that Industry Canada technical specifi cations were met.WarrantyInstantel’s products are warranted against defects in materials and workmanship and shall perform in accordance with published specifi cations for a period of one year. Instantel Inc. reserves the right to change specifi cations without notice.Limitation of LiabilityThis Product has been designed for use to assist in the prevention of infant abduction and/or mother/infant mismatching.The range, accuracy, function and performance of this Product may vary from the published specifi cations due to many factors, including, without limitation, site impairments from structural effects, metal objects in the vicinity, placement of the receiver and transmit-ter, interference from other electrical devices, atmo-spheric effects, installation, and maintenance. There may be other factors, which also affect performance of this Product. Instantel does not guarantee that this Product will detect 100% of infant abductions and/or mother/infant mismatches.  Instantel does not guarantee that this Product will not return false reports of infant abductions and/or mother/infant mismatches. Monthly testing and maintenance of this Product, as described in the Product documentation, is essential to verify the system is operating correctly and to ensure that the probability of detecting an alarm and/or locating the transmitter are maximized. The failure to undertake regular testing and main-tenance will increase the risk of system failure and failure to detect infant abductions and/or mother/infant mismatches.  The failure to undertake regular testing and maintenance will increase the risk of false reports of infant abductions and/or mother/infant mismatches.Instantel hereby disclaims all warranties, express or implied, arising out of or in connection with any of its Products of the use or performance thereof, including but not limited to, where allowable by law, all other implied warranties or conditions of merchantable quality and fi tness for a particular purpose and those arising by statute or otherwise in law or from a course of dealing or usage of trade.Instantel’s liability to you or anyone claiming through or on behalf of you with respect to any claim or loss arising out of the use or misuse of Instantel’s Product, defective products or materials, improper installation or maintenance of Instantel’s Product or products or the system in which they are incorporated, or alleged to have resulted from an act or omission of Instantel or any person, negligent or otherwise, shall be lim-ited to:A) the repair or replacement of defective Product or materials supplied by Instantel during the warranty period as set out in the Product documentation; or, at the option of Instantel,B) refund of the purchase price of the Product sup-plied by Instantel.In no event shall Instantel be liable for general, spe-cifi c, indirect, consequential, incidental, exemplary or punitive damages or any losses or expenses suffered by you or anyone else, whether or not Instantel, or its employees, offi cers, agents, resellers or installers has been informed of the risk of such loss or expense and whether or not such losses or expenses were foreseeable.Preliminary
IntroductionThe Kisses tag is part of the Kisses Mother/ Infant Matching compo-nent of the Hugs Infant Protection System. Kisses is designed to confi rm that the correct infant is matched with the correct mother each time they are brought together. The Kisses tag is given to a new mother after it has been bonded with the Hugs tag attached to her baby. The two tags remain bonded throughout the mother’s and infant’s stay in hospital, until the Hugs tag is discharged from the Hugs System.Note: The tag is not sterilized at the fac-tory. You may wish to clean the tag prior to fi rst use.Bonding the TagsThe Hugs tag and Kisses tag can be bonded any time during the one-hour period after the Hugs tag is attached to the infant. 1  Attach the Hugs tag to the infant.2  With no other Kisses tags in the area, bring the Kisses tag within 16 inches of the Hugs tag.3  The Hugs tag gives a bonding indica-tion within a few seconds:  2 short beeps, repeated once: success-ful bond persistent long beeps: the Hugs tag is seeing more than one Kisses tag no beep: battery problem4  If the bond is successful, attach the Kisses tag to the mother’s wrist using a standard hospital ID band.If the Tags Aren’t Bonding...Make sure that the tags are no more than 16 inches apart.Persistent long beeps: Check that there are no other Kisses tags within two feet. No beeps: Check the Xmark software for battery warnings. The Hugs tag will not bond with a low-battery Kisses tag. Try the bonding with a different Kisses tag.Matching the Tags“Matching” means confi rming that the right infant has been brought to the right mother. The Hugs tag provides a match or mismatch indication every time the infant is brought to its mother, when they have been apart for more than two minutes.1  Bring the Hugs tag and Kisses tag within 16 inches of each other.2  The Hugs tag gives a match/mismatch indication within two seconds: 2 short beeps, repeated once: correct match persistent long beeps: incorrect match no beep: possible mismatchIf There Is a Mismatch... Is there another mother with a Kisses tag within two feet? If yes, ask that mother to move away and try the match again. If you still get a mismatch, then the two tags do not belong to each other. Follow your hospital’s procedure for correcting a mismatch. If There Is No Match...Make sure that the tags are no more than 16 inches apart, and that there are no other Kisses tags within two feet. Check the Xmark software to confi rm that the Hugs tag bonded properly during attach-ment. If you still cannot get a match or mismatch indication, contact your System Administrator. Discharge and ReuseYou do not need to discharge the Kisses  tag. It is automatically discharged from the system when the Hugs tag is discharged in the Xmark software. Return the tag for cleaning and reuse, following the “fi rst in, fi rst out” method so that tags are cycled regularly.Cleaning the TagThe Kisses tag can be cleaned using a soft-bristle brush and a disinfectant soap or simi-lar solution with no more than 20% alcohol content (for example, Butcher’s Heptagon Disinfectant Cleaner, or KleenAseptic from Metrex Research Corp.). Dry the tag thor-oughly before use. Notes: •  Do not use an autoclave to clean the tag or serious damage may result.•  Do not soak the tag in alcohol or alco-hol-based cleaners.Handling InformationBattery Handling - this device contains a lithium battery. Do not force open, heat to 100° C, or dispose of in fi re.X-Rays - Do not directly expose the tag to X-rays. (The tag is not affected by stray radiation.)StorageStore Kisses tags at room temperature.Specifi cationsInstructions for the Kisses Mother TagFrequency 125 kHzBattery Life 1 year (warranted)Temperature 30° to 122° F (0° to 50° C)Dimensions 1.9 x 1.6 x 0.6 in(48 x 40 x 15 mm)Weight 1 oz. (28 g)

Navigation menu