Test Report issued under the
responsibility of:

TEST REPORT
IEC 60950-1

Information technology equipment – Safety –
Part 1: General requirements
Report Reference No........................ :

RP20170711050

Date of issue.........................................:

2017-07-19

Total number of pages.........................

61

Applicant’s name............................... :

SAHAB TECHNOLOGY

Address................................................. :

Ofiice 21,Qibla Tower,Fahad Al Salem St., Qibla,State of
KUWAIT

Manufacturer’s name........................:

SAHAB TECHNOLOGY

Address................................................. :

Ofiice 21,Qibla Tower,Fahad Al Salem St., Qibla,State of
KUWAIT

Factory’s name...................................:

N/A

Address................................................. :

N/A

Test specification:
Standard................................................:

IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013

Test procedure..................................... :

CE

Non-standard test method…………..:

N/A

Test Report Form No........................ :

IEC60950_1F

Test Report Form(s) Originator......... :

SGS Fimko Ltd

Master TRF........................................... :

Dated 2014-02

Test item description........................:

IP PHONE

Trade Mark............................................:

Manufacturer.........................................:
Model/Type reference......................... :

SAHAB TECHNOLOGY
XT-23G

Ratings...................................................:

Input:5Vdc,1.2A

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 2 of 61

Report No.: RP20170711050

Testing procedure and testing location:
Testing Laboratory Name:
Testing location/ address......................... :

Shenzhen Zoom Rel Testing Technology Co., Ltd.
No.2 chuangyan Rd, Liuxian Avenue, Nanshan District
Shenzhen.

Tested by (name + signature)...... :

Zhang Xiaoyang

Approved by (+ signature)............ :

Huang Pengfei

..................................

Summary of testing:
Tests performed (name of test and test clause):
The submitted samples were found to comply with
the requirements of:
- IEC 60950-1:2005+A1:2009+A2:2013
- EN 60950-1:2006+A11:2009+A1:2010+A12:2011+
A2:2013

Testing location:
Shenzhen Zoom Rel Testing Technology Co., Ltd.
No.2 chuangyan Rd, Liuxian Avenue, Nanshan
District Shenzhen.

Summary of compliance with National Differences
List of countries addressed: National Differences and Group Differences as per CB bulletin.
The product fulfils the requirements of EN60950-1:2006 + A11:2009 + A1:2010+A12: 2011+A2:2013.
Copy of marking plate:

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 3 of 61

Report No.: RP20170711050

Test item particulars..................................................... :
Equipment mobility.......................................................... :

[X] movable [] hand-held
[] transportable
[] stationary [] for building-in [] direct plug-in

Connection to the mains.................................................: [] pluggable equipment [] type A [] type B
[] permanent connection
[] detachable power supply cord
[] non-detachable power supply cord
[X] not directly connected to the mains
Operating condition......................................................... : [X] continuous
[] rated operating / resting time:
Access location ............................................................... : [X] operator accessible
[] restricted access location
Over voltage category (OVC) ....................................... : [] OVC I [] OVC II
[X] other:

[] OVC III

[] OVC IV

Mains supply tolerance (%) or absolute mains supply 5Vdc adapter power supply
values ............................................................................... :
Tested for IT power systems ........................................ : [] Yes

[X] No

IT testing, phase-phase voltage (V) .............................: N/A
Class of equipment .........................................................: [] Class I [] Class II
[] Not classified

[X] Class III

Considered current rating of protective device as part N/A
of the building installlation (A) .......................................:
Pollution degree (PD) .....................................................: [] PD 1

[X] PD 2

[] PD 3

IP protection class .......................................................... : IP20
Altitude during operation (m) ........................................ : <2000m
Altitude of test laboratory (m) ....................................... : <500m
Mass of equipment (kg) ................................................. : 1.3636Kg
Possible test case verdicts:
- test case does not apply to the test object.................. : N/A
- test object does meet the requirement........................ : P (Pass)
- test object does not meet the requirement..................: F (Fail)
Testing.............................................................................. :
Date of receipt of test item...............................................: 2017-07-05
Date(s) of performance of tests.......................................: 2017-07-05 to 2017-07-11
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
Throughout this report a

TRF No.: IEC60950_1F

comma /

point is used as the decimal separator.

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 4 of 61

Report No.: RP20170711050

General product information:
The EUT is IP phone ,it used in 45degc operating temperature.it is by adapter power supply
Following is the main board of XT-23G.

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 5 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

1

GENERAL

P

1.5

Components

P

1.5.1

General

P

Comply with IEC 60950-1 or relevant component
standard

(see appended table 1.5.1)

P

1.5.2

Evaluation and testing of components

Components which are
certified to IEC and/or
national standards are used
correctly within their ratings.
Components not covered by
IEC standards are tested
under the conditions present
in the equipment.

P

1.5.3

Thermal controls

No such parts.

N/A

1.5.4

Transformers

(see Annex C)

N/A

1.5.5

Interconnecting cables

No interconnecting cables
provided as part of the
equipment.

N/A

1.5.6

Capacitors bridging insulation

No such capacity.

N/A

1.5.7

Resistors bridging insulation

No such components
provided.

N/A

1.5.7.1

Resistors bridging functional, basic or
supplementary insulation

N/A

1.5.7.2

Resistors bridging double or reinforced insulation
between a.c. mains and other circuits

N/A

1.5.7.3

Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable

N/A

1.5.8

Components in equipment for IT power systems

1.5.9

Surge suppressors

N/A

1.5.9.1

General

N/A

1.5.9.2

Protection of VDRs

N/A

1.5.9.3

Bridging of functional insulation by a VDR

N/A

1.5.9.4

Bridging of basic insulation by a VDR

N/A

1.5.9.5

Bridging of supplementary, double or reinforced
insulation by a VDR

N/A

1.6

Power interface

1.6.1

DC power distribution systems

Not directly connect to DC
main.

N/A

1.6.2

Input current

(see appended table 1.6.2)

P

1.6.3

Voltage limit of hand-held equipment

Movable equipment

TRF No.: IEC60950_1F

Not for use on IT systems.

N/A

P

N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 6 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

1.6.4

Neutral conductor

N/A

1.7

Marking and instructions

P

1.7.1

Power rating and identification markings

P

1.7.1.1

Power rating marking

See below

Multiple mains supply
connections..........................:

Single power supply

Rated voltage(s) or voltage range(s) (V) .................: 5Vdc
Symbol for nature of supply, for d.c. only.................:

N/A
P

symbol used

Rated frequency or rated frequency range
(Hz)......:
1.7.1.2

P

P
N/A

Rated current (mA or A) .............................................: 1.2A

P

Identification markings

P

See below

Manufacturer’s name or trade-mark or identification Manufacturer’s name:
mark ........................................................................: SAHAB TECHNOLOGY

P

Trademark:

Model identification or type reference .....................: XT-23G
Symbol for Class II equipment only ........................: Class III equipment
Other markings and symbols ..................................: Additional markings are
used and are defined in the
installation instructions.

P
N/A
P

1.7.1.3

Use of graphical symbols

N/A

1.7.2

Safety instructions and marking

Operating/safety instructions
made available to the user.

P

1.7.2.1

General

See below

P

1.7.2.2

Disconnect devices

Class III equipment, not
directly connect to mains.

N/A

1.7.2.3

Overcurrent protective device

Current limited by adaptor

N/A

1.7.2.4

IT power distribution systems

Not for IT system.

N/A

1.7.2.5

Operator access with a tool

No operator access areas
require the use of a tool.

N/A

1.7.2.6

Ozone

No ozone emitted.

N/A

1.7.3

Short duty cycles

Equipment is designed for
continuous operation.

N/A

1.7.4

Supply voltage adjustment ....................................... :

Power supplied by adaptor

N/A

Methods and means of adjustment; reference to
installation instructions ..............................................:
TRF No.: IEC60950_1F

N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 7 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

1.7.5

Power outlets on the equipment ..............................:

No power outlet.

N/A

1.7.6

Fuse identification (marking, special fusing
characteristics, cross-reference) ............................. :

Power supplied by adaptor

N/A

1.7.7

Wiring terminals

N/A

1.7.7.1

Protective earthing and bonding terminals ............ :

N/A

1.7.7.2

Terminals for a.c. mains supply conductors

N/A

1.7.7.3

Terminals for d.c. mains supply conductors

N/A

1.7.8

Controls and indicators

N/A

1.7.8.1

Identification, location and marking ........................ :

N/A

1.7.8.2

Colours ....................................................................... :

N/A

1.7.8.3

Symbols according to IEC 60417............................ :

N/A

1.7.8.4

Markings using figures ............................................ :

N/A

1.7.9

Isolation of multiple power sources ........................:

Single power supply

N/A

1.7.10

Thermostats and other regulating devices ............:

No such parts in the
equipment

N/A

1.7.11

Durability

The labels were subjected to
the permanence of marking
test.

P

After tests,the labels
remained legible and no
show curling ,the marking on
the label did not fade.
1.7.12

Removable parts

No marking is located on
removable parts

N/A

1.7.13

Replaceable batteries .............................................. :

No Replaceable batteries in
the equipment

N/A

Language(s) ...............................................................:



1.7.14

Equipment for restricted access locations............. :

The equipment is not
intended to be installed in
restricted access locations.

N/A

2

PROTECTION FROM HAZARDS

P

2.1

Protection from electric shock and energy hazards

P

2.1.1

Protection in operator access areas

Only SELV circuits are
accessible.

P

2.1.1.1

Access to energized parts

See below

P

Test by inspection .......................................................: Complied

P

Test with test finger (Figure 2A) ............................... : The test finger can not
contact bare hazardous
parts.

P

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 8 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Test with test pin (Figure 2B) .................................... : The test pin can not contact
bare hazardous parts.

Verdict
P

Test with test probe (Figure 2C) ...............................: No TNV circuit.

N/A

2.1.1.2

Battery compartments

N/A

2.1.1.3

Access to ELV wiring

No battery compartment.

N/A

Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)

(see appended table 2.10.5)

2.1.1.4

Access to hazardous voltage circuit wiring

No accessible hazardous
voltage circuit wiring.

2.1.1.5

Energy hazards ........................................................... : No energized part contains
in equipment.

N/A

2.1.1.6

Manual controls

No knobs and the like are
connected to parts at
hazardous voltage.

N/A

2.1.1.7

Discharge of capacitors in equipment

SELV circuit

N/A

Measured voltage (V); time-constant (s).................. :
2.1.1.8


N/A



Energy hazards – d.c. mains supply

N/A

a) Capacitor connected to the d.c. mains supply ...:

N/A

b) Internal battery connected to the d.c. mains
supply ............................................................................:

N/A

2.1.1.9

Audio amplifiers ...........................................................: No audio amplifiers

N/A

2.1.2

Protection in service access areas

N/A

2.1.3

Protection in restricted access locations

2.2

SELV circuits

2.2.1

General requirements

2.2.2

Voltages under normal conditions (V) ..................... : All accessible voltages are
less than 42.4 Vp or 60 V dc
and are classified as SELV.

P

2.2.3

P

2.2.4

Voltages under fault conditions (V) .......................... : Under fault conditions
voltages never exceed 71V
peak and 120Vdc and do
not exceed 42.4V peak or
60V dc for more than 0.2
sec.
Connection of SELV circuits to other circuits ....... : SELV to SELV

2.3

TNV circuits

P

2.3.1

Limits

P

TRF No.: IEC60950_1F

Not intended for installation
in restricted access
locations.

N/A

P
(see appended table 2.2)

P

P

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 9 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

Type of TNV circuits.................................................... : TNV-2



2.3.2

Separation from other circuits and from accessible
parts

P

2.3.2.1

General requirements

P

2.3.2.2

Protection by basic insulation

N/A

2.3.2.3

Protection by earthing

N/A

2.3.2.4

Protection by other constructions .............................:

N/A

2.3.3

Separation from hazardous voltages

N/A

2.3.4

Insulation employed.....................................................:



Connection of TNV circuits to other circuits

P

Insulation employed.....................................................: Other insulation



2.3.5

Test for operating voltages generated externally

N/A

2.4

Limited current circuits

N/A

2.4.1

General requirements

2.4.2

Limit values

No limited current circuits

N/A
N/A

Frequency (Hz).............................................................:



Measured current (mA)............................................... :



Measured voltage (V).................................................. :



Measured circuit capacitance (nF or µF)................. :



2.4.3

Connection of limited current circuits to other
circuits

N/A

2.5

Limited power sources
a) Inherently limited output

(see appended table 2.5)

N/A
N/A

b) Impedance limited output

(see appended table 2.5)

N/A
N/A

c) Regulating network limited output under normal
operating and single fault condition
d) Overcurrent protective device limited output

(see appended table 2.5)

N/A

Max. output voltage (V), max. output current (A),
max. apparent power (VA)......................................... :



Current rating of overcurrent protective device (A) .:


N/A

Use of integrated circuit (IC) current limiters

(See Annex CC)

2.6

Provisions for earthing and bonding

N/A

2.6.1

Protective earthing

N/A

2.6.2

Functional earthing

N/A

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 10 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

Use of symbol for functional earthing ...................:

N/A

2.6.3

Protective earthing and protective bonding
conductors

N/A

2.6.3.1

General

N/A

2.6.3.2

Size of protective earthing conductors

N/A

Rated current (A), cross-sectional area (mm ),
AWG...............................................................................:
2

2.6.3.3



Size of protective bonding conductors

N/A

Rated current (A), cross-sectional area (mm2),
AWG...............................................................................:



Protective current rating (A), cross-sectional area
(mm2), AWG..................................................................:



2.6.3.4

Resistance of earthing conductors and their
terminations; resistance (), voltage drop (V), test
current (A), duration (min).......................................... :

N/A

2.6.3.5

Colour of insulation......................................................:

N/A

2.6.4

Terminals

N/A

2.6.4.1

General

N/A

2.6.4.2

Protective earthing and bonding terminals

N/A

Rated current (A), type, nominal thread diameter
(mm)...............................................................................:



2.6.4.3

Separation of the protective earthing conductor
from protective bonding conductors

N/A

2.6.5

Integrity of protective earthing

N/A

2.6.5.1

Interconnection of equipment

N/A

2.6.5.2

Components in protective earthing conductors and
protective bonding conductors

N/A

2.6.5.3

Disconnection of protective earth

N/A

2.6.5.4

Parts that can be removed by an operator

N/A

2.6.5.5

Parts removed during servicing

N/A

2.6.5.6

Corrosion resistance

N/A

2.6.5.7

Screws for protective bonding

N/A

2.6.5.8

Reliance on telecommunication network or cable
distribution system

N/A

2.7

Overcurrent and earth fault protection in primary circuits

N/A

2.7.1

Basic requirements

N/A

2.7.2

No primary circuit.

Instructions when protection relies on building
installation

N/A

Faults not simulated in 5.3.7

N/A

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 11 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

2.7.3

Short-circuit backup protection

N/A

2.7.4

Number and location of protective devices ............ :

N/A

2.7.5

Protection by several devices

N/A

2.7.6

Warning to service personnel.................................... :

N/A

2.8

Safety interlocks

2.8.1

General principles

N/A
N/A

2.8.2

Protection requirements

N/A

2.8.3

Inadvertent reactivation

N/A

2.8.4

Fail-safe operation

N/A

Protection against extreme hazard

N/A

2.8.5

Moving parts

N/A

2.8.6

Overriding

N/A

2.8.7

Switches, relays and their related circuits

N/A

2.8.7.1

Separation distances for contact gaps and their
related circuits
(mm)................................................:

N/A

2.8.7.2

Overload test

N/A

2.8.7.3

Endurance test

N/A

2.8.7.4

Electric strength test

2.8.8

Mechanical actuators

N/A

2.9

Electrical insulation

N/A

2.9.1

Properties of insulating materials

N/A

2.9.2

Humidity conditioning

N/A

No safety interlocks
provided.

(see appended table 5.2)

Relative humidity (%), temperature (°C) ................. :

N/A



2.9.3

Grade of insulation

N/A

2.9.4

Separation from hazardous voltages

N/A

Method(s) used ........................................................... :



2.10

Clearances, creepage distances and distances through insulation

N/A

2.10.1

General

N/A

2.10.1.1

Frequency .................................................................... :

N/A

2.10.1.2

Pollution degrees ........................................................ :

N/A

2.10.1.3

Reduced values for functional insualtion

N/A

2.10.1.4

Intervening unconnected conductive parts

N/A

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 12 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

2.10.1.5

Insulation with varying dimensions

N/A

2.10.1.6

Special separation requirements

N/A

2.10.1.7

Insulation in circuits generating starting pulses

N/A

2.10.2

Determination of working voltage

N/A

2.10.2.1

General

N/A

2.10.2.2

RMS working voltage

N/A

2.10.2.3

Peak working voltage

N/A

2.10.3

Clearances

N/A

2.10.3.1

General

2.10.3.2

Mains transient voltages

N/A
N/A

a) AC mains supply .....................................................:

N/A

b) Earthed d.c. mains supplies ................................. :

N/A

c) Unearthed d.c. mains supplies ............................. :

N/A

d) Battery operation .................................................... :

N/A

2.10.3.3

Clearances in primary circuits

N/A

2.10.3.4

Clearances in secondary circuits

N/A

2.10.3.5

Clearances in circuits having starting pulses

N/A

2.10.3.6

Transients from a.c. mains supply ........................... :

N/A

2.10.3.7

Transients from d.c. mains supply ........................... :

N/A

2.10.3.8

Transients from telecommunication networks and
cable distribution systems ......................................... :

N/A

2.10.3.9

Measurement of transient voltage levels

N/A

a) Transients from a mains suplply

N/A

For an a.c. mains supply ............................................:

N/A

For a d.c. mains supply ..............................................:

N/A

b) Transients from a telecommunication network :

N/A

2.10.4

Creepage distances

N/A

2.10.4.1

General

N/A

2.10.4.2

Material group and caomparative tracking index

N/A

CTI tests........................................................................ :



2.10.4.3

Minimum creepage distances

N/A

2.10.5

Solid insulation

N/A

2.10.5.1

General

2.10.5.2

Distances through insulation

N/A
N/A

2.10.5.3

Insulating compound as solid insulation

N/A

2.10.5.4

Semiconductor devices

N/A

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 13 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

2.10.5.5.

Cemented joints

N/A

2.10.5.6

Thin sheet material – General

N/A

2.10.5.7

Separable thin sheet material

N/A

Number of layers (pcs)................................................:



2.10.5.8

Non-separable thin sheet material

N/A

2.10.5.9

Thin sheet material – standard test procedure

N/A

Electric strength test
2.10.5.10



Thin sheet material – alternative test procedure

N/A

Electric strength test
2.10.5.11

Insulation in wound components


N/A

2.10.5.12

Wire in wound components

N/A

Working voltage ...........................................................:

N/A

a) Basic insulation not under stress ......................... :

N/A

b) Basic, supplemetary, reinforced insulation ........ :

N/A

c) Compliance with Annex U ..................................... :

N/A

Two wires in contact inside wound component;
angle between 45 and 90 ....................................... :

N/A

Wire with solvent-based enamel in wound
components

N/A

Electric strength test
Routine test


N/A

Additional insulation in wound components

N/A

Working voltage ...........................................................:

N/A

- Basic insulation not under stress ........................... :

N/A

- Supplemetary, reinforced insulation ...................... :

N/A

2.10.6

Construction of printed boards

N/A

2.10.6.1

Uncoated printed boards

N/A

2.10.6.2

Coated printed boards

N/A

2.10.6.3

Insulation between conductors on the same inner
surface of a printed board

N/A

2.10.6.4

Insulation between conductors on different layers
of a printed board

N/A

Distance through insulation

N/A

Number of insulation layers (pcs)..............................:

N/A

2.10.7

Component external terminations

N/A

2.10.8

Tests on coated printed boards and coated
components

N/A

2.10.5.13

2.10.5.14

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 14 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

2.10.8.1

Sample preparation and preliminary inspection

N/A

2.10.8.2

Thermal conditioning

N/A

2.10.8.3

Electric strength test

N/A

2.10.8.4

Abrasion resistance test

N/A

2.10.9

Thermal cycling

N/A

2.10.10

Test for Pollution Degree 1 environment and
insulating compound

N/A

2.10.11

Tests for semiconductor devices and cemented
joints

N/A

2.10.12

Enclosed and sealed parts

N/A

3

WIRING, CONNECTIONS AND SUPPLY

P

3.1

General

P

3.1.1

Current rating and overcurrent protection

P

3.1.2

Protection against mechanical damage

The wires are routed away
from sharp edges and parts
which could damage
insulation.

P

3.1.3

Securing of internal wiring

The wires are positioned in
such a manner that prevents
excessive strain, loosening
of terminal connections and
damage of conductor
insulation.

N/A

3.1.4

Insulation of conductors

Insulation on internal
conductor are considered to
be of adequate quality and
suitable for the application
and the working voltages
involved.

N/A

3.1.5

Beads and ceramic insulators

No beads or similar ceramic
insulators on conductors.

N/A

3.1.6

Screws for electrical contact pressure

No screws for electrical
contact pressure.

N/A

3.1.7

Insulating materials in electrical connections

No contact pressure through
insulating material.

N/A

3.1.8

Self-tapping and spaced thread screws

Thread-cutting or space
thread screws are not used
for electrical connections.
Machine screws only.

N/A

3.1.9

Termination of conductors

N/A

10 N pull test

N/A

Sleeving on wiring

N/A

3.1.10

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 15 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

3.2

Connection to a mains supply

N/A

3.2.1

Means of connection

3.2.1.1

Connection to an a.c. mains supply

N/A

3.2.1.2

Connection to a d.c. mains supply

N/A

3.2.2

Multiple supply connections

3.2.3

Permanently connected equipment

Not directly connect to
mains

Single power supply.
The equipment is not
permanently connected.
See clause 3.2.1.1 and 3.3.

Number of conductors, diameter of cable and
conduits (mm) ..............................................................:

N/A

N/A
N/A


3.2.4

Appliance inlets

N/A

3.2.5

Power supply cords

N/A

3.2.5.1

AC power supply cords

N/A

Type .............................................................................. :



Rated current (A), cross-sectional area (mm ),
AWG ............................................................................. :



2

3.2.5.2

DC power supply cords

N/A

3.2.6

Cord anchorages and strain relief

N/A

Mass of equipment (kg), pull (N) .............................:



Longitudinal displacement (mm) .............................. :



3.2.7

Protection against mechanical damage

N/A

3.2.8

Cord guards

N/A

Diameter or minor dimension D (mm); test mass (g)
........................................................................................ :



Radius of curvature of cord (mm)..............................:



3.2.9

Supply wiring space

N/A

3.3

Wiring terminals for connection of external conductors

N/A

3.3.1

Wiring terminals

N/A

3.3.2

Connection of non-detachable power supply cords

N/A

3.3.3

Screw terminals

N/A

3.3.4

Conductor sizes to be connected

N/A

Rated current (A), cord/cable type, cross-sectional
area (mm2).................................................................... :
3.3.5

Wiring terminal sizes

N/A

Rated current (A), type, nominal thread diameter
(mm) ..............................................................................:
TRF No.: IEC60950_1F





Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 16 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

3.3.6

Wiring terminal design

N/A

3.3.7

Grouping of wiring terminals

N/A

3.3.8

Stranded wire

N/A

3.4

Disconnection from the mains supply

N/A

3.4.1

General requirement

3.4.2

Disconnect devices

3.4.3

Permanently connected equipment

Not permanently connected
equipment.

N/A

3.4.4

Parts which remain energized

No parts remain energized
after the disconnect device
is switched off.

N/A

3.4.5

Switches in flexible cords

No isolating switch in the
cord set.

N/A

3.4.6

Number of poles - single-phase and d.c.
equipment

N/A

3.4.7

Number of poles - three-phase equipment

N/A

3.4.8

Switches as disconnect devices

N/A

3.4.9

Plugs as disconnect devices

N/A

3.4.10

Interconnected equipment

N/A

3.4.11

Multiple power sources

3.5

Interconnection of equipment

3.5.1

General requirements

See below

P

3.5.2

Types of interconnection circuits ..............................:

SELV to SELV

P

3.5.3

ELV circuits as interconnection circuits

No ELV circuit

N/A

3.5.4

Data ports for additional equipment

P

4

PHYSICAL REQUIREMENTS

P

4.1

Stability

N/A

Angle of 10

N/A

Test force (N) ...............................................................: Not floor-standing
equipment.

N/A

Not directly connect to
mains

N/A
N/A

Single power supply only.

N/A
P

4.2

Mechanical strength

4.2.1

General

Class Ⅲ equipment.

N/A

Rack-mounted equipment.

(see Annex DD)

N/A

4.2.2

Steady force test, 10 N

TRF No.: IEC60950_1F

P

Complied

P

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 17 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

4.2.3

Steady force test, 30 N

N/A

4.2.4

Steady force test, 250 N

4.2.5

Impact test

N/A

Fall test

N/A

Swing test

N/A

Complied

4.2.6

Drop test; height (mm) ............................................... : Height:750mm, 3 times, no
hazard

4.2.7

Stress relief test

4.2.8

Cathode ray tubes

P

P
N/A

No CRT provided.

N/A
N/A

No high pressure lamp.

N/A

Picture tube separately certified ............................... :
4.2.9

High pressure lamps

4.2.10

Wall or ceiling mounted equipment; force (N) ........ :

4.3

Design and construction

4.3.1

Edges and corners

4.3.2

Handles and manual controls; force (N).................:

4.3.3

Adjustable controls

4.3.4

Securing of parts

Parts are reliably secured

P

4.3.5

Connection by plugs and sockets

SELV connectors do not
comply with IEC 60320 or
IEC 60083.

P

4.3.6

Direct plug-in equipment

Not direct plug-in equipment

N/A
P
Round and smooth
No knobs, grips, handles,
lever etc.
The equipment is autoranging.

P
N/A
N/A

N/A

Torque ......................................................................... :



Compliance with the relevant mains plug
standard ...................................................................... :

N/A

4.3.7

Heating elements in earthed equipment

The equipment does not
have any heating elements.

N/A

4.3.8

Batteries

The equipment does not
have any batteries.

N/A

- Overcharging of a rechargeable battery

N/A

- Unintentional charging of a non-rechargeable
battery

N/A

- Reverse charging of a rechargeable battery

N/A

- Excessive discharging rate for any battery

N/A

4.3.9

Oil and grease

N/A

4.3.10

Dust, powders, liquids and gases

TRF No.: IEC60950_1F

Equipment in intended use
not considered to be
exposed to these.

N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 18 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

4.3.11

Containers for liquids or gases

The equipment does not
contain liquids.

N/A

4.3.12

Flammable liquids ......................................................:

The equipment does not use
any flammable liquids.

N/A

Quantity of liquid (l) ....................................................:

N/A

Flash point (C) .......................................................... :

N/A

4.3.13

Radiation

4.3.13.1

General

4.3.13.2

Ionizing radiation

4.3.13.3

P
Indicating LED only

P
N/A

Measured radiation (pA/kg) ......................................:



Measured high-voltage (kV) .....................................:



Measured focus voltage (kV) ................................... :



CRT markings ............................................................ :


N/A

Effect of ultraviolet (UV) radiation on materials

No ultraviolet radiation.

Part, property, retention after test, flammability
classification ............................................................... :

N/A

4.3.13.4

Human exposure to ultraviolet (UV) radiation ....... :

N/A

4.3.13.5

Lasers (including laser diodes) and LEDs

4.3.13.5.1

Lasers (including laser laser diodes)

Indicating LED only

P
N/A

Laser class ..................................................................:



4.3.13.5.2

Light emitting diodes (LEDs)

P

4.3.13.6

Other types ................................................................. :

N/A

4.4

Protection against hazardous moving parts

4.4.1

General

N/A
N/A

4.4.2

Protection in operator access areas ....................... :

N/A

Household and home/office document/media
shredders

N/A

4.4.3

Protection in restricted access locations ................:

N/A

4.4.4

Protection in service access areas

N/A

4.4.5

Protection against moving fan blades

4.4.5.1

General

N/A
N/A

Not considered to cause pain or injury.
a)………….:

N/A

Is considered to cause pain, not injury.
b) …………:

N/A

Considered to cause injury.
c) …………:

N/A

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 19 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause
4.4.5.2

4.4.5.3

Requirement + Test

Result - Remark

Verdict

Protection for users

N/A

Use of symbol or
warning ………………...…………:

N/A

Protection for service persons

N/A

Use of symbol or
warning ……………………...……:

N/A

4.5

Thermal requirements

P

4.5.1

General

The equipment and its
components did not attain
excessive temperatures
during normal operation.

P

4.5.2

Temperature tests

(see appended table 4.5)

P

Normal load condition per Annex L .........................:



4.5.3

Temperature limits for materials

(see appended table 4.5)

P

4.5.4

Touch temperature limits

(see appended table 4.5)

P

4.5.5

Resistance to abnormal heat ................................... :

(see appended table 4.5.5)

4.6

Openings in enclosures

4.6.1

Top and side openings

P
No openings

Dimensions (mm) .......................................................:
4.6.2

N/A

Bottoms of fire enclosures

N/A


Complied

Construction of the bottomm, dimensions (mm) ...:

P


4.6.3

Doors or covers in fire enclosures

No doors.

N/A

4.6.4

Openings in transportable equipment

Not transportable.

N/A

4.6.4.1

Constructional design measures

N/A

Dimensions (mm) .......................................................:
4.6.4.2

Evaluation measures for larger openings


N/A

4.6.4.3

Use of metallized parts

N/A

4.6.5

Adhesives for constructional purposes

N/A

Conditioning temperature (C), time (weeks)......... :



4.7

Resistance to fire

P

4.7.1

Reducing the risk of ignition and spread of flame

Use of materials with the
required flammability
classes.

P

Method 1, selection and application of components (see appended table 4.7)
wiring and materials

P

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 20 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Method 2, application of all of simulated fault
condition tests

Method 1 used

Verdict
N/A

4.7.2

Conditions for a fire enclosure

P

4.7.2.1

Parts requiring a fire enclosure

P

4.7.2.2

Parts not requiring a fire enclosure

4.7.3

Materials

4.7.3.1

General

4.7.3.2

Materials for fire enclosures

N/A

4.7.3.3

Materials for components and other parts outside
fire enclosures

N/A

4.7.3.4

Materials for components and other parts inside
fire enclosures

At least of flammability class
V-2 or HF-2.

4.7.3.5

Materials for air filter assemblies

The equipment does not
have any air filters.

N/A

4.7.3.6

Materials used in high-voltage components

No high voltage component.

N/A

5

ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS

N/A

5.1

Touch current and protective conductor current

5.1.1

General

N/A
N/A

5.1.2

Configuration of equipment under test (EUT)

N/A

5.1.2.1

Single connection to an a.c. mains supply

N/A

5.1.2.2

Redundant multiple connections to an a.c. mains
supply

N/A

5.1.2.3

Simultaneous multiple connections to an a.c.
mains supply

N/A

5.1.3

Test circuit

N/A

5.1.4

Application of measuring instrument

N/A

5.1.5

Test procedure

N/A

5.1.6

Test measurements

N/A

N/A
P
All components are
mounted on the PCB of min.
V-1.

P

P

Supply voltage (V) ..................................................... :



Measured touch current (mA) .................................. :



Max. allowed touch current (mA) .............................:



Measured protective conductor current (mA) ........:



Max. allowed protective conductor current (mA)... :



5.1.7

Equipment with touch current exceeding 3,5 mA

N/A

5.1.7.1

General ........................................................................:

N/A

5.1.7.2

Simultaneous multiple connections to the supply

N/A

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 21 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

5.1.8

Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks

N/A

5.1.8.1

Limitation of the touch current to a
telecommunication network or to a cable
distribution system

N/A

5.1.8.2

Supply voltage (V) ..................................................... :



Measured touch current (mA) .................................. :



Max. allowed touch current (mA) .............................:



Summation of touch currents from
telecommunication networks

N/A

a) EUT with earthed telecommunication ports ...... :

N/A

b) EUT whose telecommunication ports have no
reference to protective earth

N/A

5.2

Electric strength

5.2.1

General

5.2.2

Test procedure

P

5.3

Abnormal operating and fault conditions

P

5.3.1

Protection against overload and abnormal
operation

(see appended table 5.3)

P

5.3.2

Motors

(see appended Annex B)

N/A

5.3.3

Transformers

(see appended Annex C)

N/A

5.3.4

Functional insulation...................................................:

5.3.5

Electromechanical components

N/A

5.3.6

Audio amplifiers in ITE .............................................. :

N/A

5.3.7

Simulation of faults

5.3.8

Unattended equipment

5.3.9

Compliance criteria for abnormal operating and
fault conditions

P

5.3.9.1

During the tests

P

5.3.9.2

After the tests

P

6

CONNECTION TO TELECOMMUNICATION NETWORKS

N/A

6.1

Protection of telecommunication network service persons, and users of
other equipment connected to the network, from hazards in the equipment

N/A

6.1.1

Protection from hazardous voltages

N/A

6.1.2

Separation of the telecommunication network from earth

N/A

TRF No.: IEC60950_1F

P
(see appended table 5.2)

P

P

(see appended table 5.3)

P
N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 22 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause
6.1.2.1

Requirement + Test

Result - Remark

Requirements

(see appended table 5.2)

Verdict
N/A

Supply voltage (V) ..................................................... :



Current in the test circuit (mA) ...............................:



6.1.2.2

Exclusions ...................................................................:

N/A

6.2

Protection of equipment users from overvoltages on telecommunication
networks

N/A

6.2.1

Separation requirements

N/A

6.2.2

Electric strength test procedure

N/A

6.2.2.1

Impulse test

(see appended table 5.2)

N/A

6.2.2.2

Steady-state test

(see appended table 5.2)

N/A

6.2.2.3

Compliance criteria

N/A

6.3

Protection of the telecommunication wiring system from overheating

N/A

Max. output current (A) ............................................. :



Current limiting method .............................................:



7

CONNECTION TO CABLE DISTRIBUTION SYSTEMS

N/A

7.1

General

N/A

7.2

Protection of cable distribution system service
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment

7.3

Protection of equipment users from overvoltages
on the cable distribution system

N/A

7.4

Insulation between primary circuits and cable
distribution systems

N/A

7.4.1

General

N/A

7.4.2

Voltage surge test

(see appended table 5.2)

N/A

7.4.3

Impulse test

(see appended table 5.2)

N/A

A

ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE

N/A

A.1

Flammability test for fire enclosures of
movable equipment having a total mass
exceeding 18 kg, and of stationary equipment
(see 4.7.3.2)

N/A

A.1.1

Samples........................................................................:



Wall thickness (mm)................................................... :



Conditioning of samples; temperature (C) ........... :

N/A

A.1.2

TRF No.: IEC60950_1F

No connection to CABLE
DISTRIBUTION SYSTEMS.

N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 23 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

A.1.3

Mounting of samples ................................................. :

N/A

A.1.4

Test flame (see IEC 60695-11-3)

N/A

Flame A, B, C or D .................................................... :



A.1.5

Test procedure

N/A

A.1.6

Compliance criteria

N/A

Sample 1 burning time (s)......................................... :



Sample 2 burning time (s)......................................... :



Sample 3 burning time (s)......................................... :



A.2

Flammability test for fire enclosures of movable equipment having a total
mass not exceeding 18 kg, and for material and components located inside
fire enclosures (see 4.7.3.2 and 4.7.3.4)

A.2.1

Samples, material....................................................... :



Wall thickness (mm)................................................... :



A.2.2

Conditioning of samples; temperature (°C) ........... :

N/A

A.2.3

Mounting of samples ................................................. :

N/A

A.2.4

Test flame (see IEC 60695-11-4)

N/A

Flame A, B or C ..........................................................:

N/A



A.2.5

Test procedure

N/A

A.2.6

Compliance criteria

N/A

A.2.7

Sample 1 burning time (s)......................................... :



Sample 2 burning time (s)......................................... :



Sample 3 burning time (s)......................................... :



Alternative test acc. to IEC 60695-11-5, cl. 5 and 9

N/A

Sample 1 burning time (s)......................................... :



Sample 2 burning time (s)......................................... :



Sample 3 burning time (s)......................................... :



A.3

Hot flaming oil test (see 4.6.2)

N/A

A.3.1

Mounting of samples

N/A

A.3.2

Test procedure

N/A

A.3.3

Compliance criterion

N/A

B

ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2
and 5.3.2)

N/A

B.1

General requirements

N/A

Position ........................................................................:



Manufacturer .............................................................. :



TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 24 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

Type ............................................................................. :



Rated values ..............................................................:


N/A

B.2

Test conditions

B.3

Maximum temperatures

(see appended table 5.3)

N/A

B.4

Running overload test

(see appended table 5.3)

N/A

B.5

Locked-rotor overload test

N/A

Test duration (days) .................................................. :



Electric strength test: test voltage (V) .....................:



B.6

Running overload test for d.c. motors in
secondary circuits

N/A

B.6.1

General

N/A

B.6.2

Test procedure

N/A

B.6.3

Alternative test procedure

N/A

B.6.4

Electric strength test; test voltage (V) .....................:

N/A

B.7

Locked-rotor overload test for d.c. motors in
secondary circuits

N/A

B.7.1

General

N/A

B.7.2

Test procedure

N/A

B.7.3

Alternative test procedure

N/A

B.7.4

Electric strength test; test voltage (V) ....................:

N/A

B.8

Test for motors with capacitors

(see appended table 5.3)

N/A

B.9

Test for three-phase motors

(see appended table 5.3)

N/A

B.10

Test for series motors

N/A

Operating voltage (V) ................................................ :
C



ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3)

N/A

Position ........................................................................:



Manufacturer .............................................................. :



Type ............................................................................. :



Rated values ..............................................................:



Method of protection.................................................. :


N/A

C.1

Overload test

(see appended table 5.3)

C.2

Insulation

(see appended tables 5.2
and C2)

Protection from displacement of windings.............. :

TRF No.: IEC60950_1F

N/A
N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 25 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

D

ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS
(see 5.1.4)

N/A

D.1

Measuring instrument

N/A

D.2

Alternative measuring instrument

N/A

E

ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13)

N/A

F

ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10 and Annex G)

N/A

G

ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES

N/A

G.1

Clearances

N/A

G.1.1

General

N/A

G.1.2

Summary of the procedure for determining
minimum clearances

N/A

G.2

Determination of mains transient voltage (V)

N/A

G.2.1

AC mains supply ........................................................ :

N/A

G.2.2

Earthed d.c. mains supplies .....................................:

N/A

G.2.3

Unearthed d.c. mains supplies ................................ :

N/A

G.2.4

Battery operation ........................................................:

N/A

G.3

Determination of telecommunication network
transient voltage (V) ............................................... :

N/A

G.4

Determination of required withstand voltage (V)

N/A

G.4.1

Mains transients and internal repetitive peaks ......:

N/A

G.4.2

Transients from telecommunication networks .......:

N/A

G.4.3

Combination of transients

N/A

G.4.4

Transients from cable distribution systems

N/A

G.5

Measurement of transient voltages (V)

N/A

a) Transients from a mains supply

N/A

For an a.c. mains supply

N/A

For a d.c. mains supply

N/A

b) Transients from a telecommunication network

N/A

G.6

Determination of minimum clearances ............. :

N/A

H

ANNEX H, IONIZING RADIATION (see 4.3.13)

N/A

J

ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)

N/A

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 26 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Metal(s) used ..............................................................:

Verdict


K

ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8)

K.1

Making and breaking capacity

N/A
N/A

K.2

Thermostat reliability; operating voltage (V) ..........:

N/A

K.3

Thermostat endurance test; operating voltage
(V) ................................................................................:

N/A

K.4

Temperature limiter endurance; operating voltage
(V) .................................................................................:

N/A

K.5

Thermal cut-out reliability

N/A

K.6

Stability of operation

L

ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF
ELECTRICAL BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)

N/A

L.1

Typewriters

N/A

L.2

Adding machines and cash registers

N/A

L.3

Erasers

N/A

L.4

Pencil sharpeners

N/A

L.5

Duplicators and copy machines

N/A

L.6

Motor-operated files

N/A

L.7

Other business equipment

N/A

M

ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)

M.1

Introduction

N/A
N/A

M.2

Method A

N/A

M.3

Method B

N/A

M.3.1

Ringing signal

N/A

M.3.1.1

Frequency (Hz) .......................................................... :



M.3.1.2

Voltage (V) .................................................................. :



M.3.1.3

Cadence; time (s), voltage (V) .................................:



M.3.1.4

Single fault current (mA) ...........................................:

M.3.2

Tripping device and monitoring voltage ................. :


N/A

M.3.2.1

Conditions for use of a tripping device or a
monitoring voltage

N/A

M.3.2.2

Tripping device

N/A

M.3.2.3

Monitoring voltage (V) ...............................................:

N/A

TRF No.: IEC60950_1F

(see appended table 5.3)

N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 27 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

N

ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9,
6.2.2.1, 7.3.2, 7.4.3 and Clause G.5)

N/A

N.1

ITU-T impulse test generators

N/A

N.2

IEC 60065 impulse test generator

N/A

P

ANNEX P, NORMATIVE REFERENCES

Q

ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1)



a) Preferred climatic categories ...............................:

N/A
N/A

b) Maximum continuous voltage ..............................:

N/A

c) Pulse current .......................................................... :

N/A

R

ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES

N/A

R.1

Minimum separation distances for unpopulated
coated printed boards (see 2.10.6.2)

N/A

R.2

Reduced clearances (see 2.10.3)

N/A

S

ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)

S.1

Test equipment

N/A
N/A

S.2

Test procedure

N/A

S.3

Examples of waveforms during impulse testing

N/A

T

ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER
(see 1.1.2)

N/A


U

ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)

N/A


V

ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)

N/A

V.1

Introduction

N/A

V.2

TN power distribution systems

N/A

W

ANNEX W, SUMMATION OF TOUCH CURRENTS

W.1

Touch current from electronic circuits

N/A
N/A

W.1.1

Floating circuits

N/A

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 28 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

W.1.2

Earthed circuits

N/A

W.2

Interconnection of several equipments

N/A

W.2.1

Isolation

N/A

W.2.2

Common return, isolated from earth

N/A

W.2.3

Common return, connected to protective earth

N/A

X

ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS
(see clause C.1)

N/A

X.1

Determination of maximum input current

N/A

X.2

Overload test procedure

N/A

Y

ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)

Y.1

Test apparatus ........................................................... :

N/A
N/A

Y.2

Mounting of test samples ..........................................:

N/A

Y.3

Carbon-arc light-exposure apparatus .....................:

N/A

Y.4

Xenon-arc light exposure apparatus .......................:

N/A

Z

ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2)

N/A

AA

ANNEX AA, MANDREL TEST (see 2.10.5.8)

N/A

BB

ANNEX BB, CHANGES IN THE SECOND EDITION

CC

Annex CC, Evaluation of integrated circuit (IC) current limiters

N/A

CC.1

General

N/A

CC.2

Test program 1………………….............………….:

N/A

CC.3

Test program 2……………………….........……….:

N/A

CC.4

Test program 3.....................................................:

N/A

CC.5

Compliance..........................................................:

N/A

DD

Annex DD, Requirements for the mounting means of rack-mounted
equipment

N/A

DD.1

General:

N/A

DD.2

Mechanical strength test, variable N……..…..::

N/A

DD.3

Mechanical strength test, 250N, including end
stops……………………………………………...:

N/A

DD.4

Compliance……………………………....………:

N/A

TRF No.: IEC60950_1F



Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 29 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

EE

Annex EE, Household and home/office document/media shredders

EE.1

General:

N/A
N/A

EE.2

Markings and instructions

N/A

Use of markings or symbols………...…………:

N/A

Information of user instructions, maintenance
and/or servicing instructions……………………:

N/A

EE.3

Inadvertent reactivation test………………....…:

N/A

EE.4

Disconnection of power to hazardous moving parts:

N/A

Use of markings or symbols……………………:

N/A

Protection against hazardous moving parts

N/A

Test with test finger (Figure 2A) ………………:

N/A

Test with wedge probe (Figure EE1 and EE2).:

N/A

EE.5

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 30 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

1.5.1

Requirement + Test

Result - Remark

TABLE: List of critical components

P

Object/part No.

Manufacturer/
Type/model
Technical data
trademark
PCB
Interchangeable Interchangeable V-0,105°C
RJ11 jack
Interchangeable Interchangeable RJ11
Internal Wiring Interchangeable Interchangeable Min. VW-1,80℃
Min. HB,
Enclosure
Interchangeable Interchangeable
min.85℃
Input: AC100240V, 50/60Hz
0.18A
Adapter
Interchangeable Interchangeable Output:DC5V
12
00mA,complied
with LPS.
Supplementary information:
1)

Verdict

Standard
(Edition / year)
UL 796
-UL 758

Mark(s) of
conformity1)
UL
UL
UL

UL 94

UL

EN 60950-1

CE NB

Provided evidence ensures the agreed level of compliance. See OD-CB2039.

1.5.1

TABLE: Opto Electronic Devices

N/A

Manufacturer..................................................... :
Type....................................................................:
Separately tested............................................. :
Bridging insulation............................................ :
External creepage distance............................ :
Internal creepage distance............................. :
Distance through insulation............................ :
Tested under the following conditions...........:
Input....................................................................:
Output.................................................................:
supplementary information

1.6.2

TABLE: Electrical data (in normal conditions)

P

U (V)

I (A)

Irated (A)

P (W)

Fuse #

Ifuse (A)

5Vdc

0.029A

1.2A

2.574W

-

-

TRF No.: IEC60950_1F

Condition/status
The EUT in normal operating
conditions.

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 31 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

Supplementary information:
2.1.1.5 c)
1)

N/A

TABLE: max. V, A, VA test

Voltage (rated)
(V)

Current (rated)
(A)

Voltage (max.)
(V)

Current (max.)
(A)

VA (max.)
(VA)

supplementary information:

2.1.1.5 c)
2)

N/A

TABLE: stored energy

Capacitance C (µF)

Voltage U (V)

Energy E (J)

supplementary information:

2.2

TABLE: evaluation of voltage limiting components in SELV circuits

Component (measured between)

max. voltage (V)
(normal operation)
V peak

Fault test performed on voltage limiting components

N/A

Voltage Limiting Components

V d.c.

Voltage measured (V) in SELV circuits
(V peak or V d.c.)

supplementary information:

2.5

TABLE: limited power sources

N/A

Circuit output tested:
Note: Measured Uoc (V) with all load circuits disconnected:
Components

Sample No,

Uoc (V)

Isc (A)
Meas.

VA
Limit

Meas.

Limit

supplementary information:
Sc=Short circuit, Oc=Open circuit

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 32 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

2.10.2

Table: working voltage measurement

Location

Result - Remark

RMS voltage (V)

Verdict
N/A

Peak voltage (V) Comments

supplementary information:

2.10.3 and
2.10.4

TABLE: Clearance and creepage distance measurements

Clearance (cl) and creepage
distance (cr) at/of/between:

U peak
(V)

U r.m.s.
(V)

Required cl
(mm)

cl
(mm)

N/A
Required cr
(mm)

cr
(mm)

Functional:
Basic/supplementary:
Reinforced:
Supplementary information:
2.10.5

TABLE: Distance through insulation measurements

Distance through insulation (DTI) at/of:

U peak
(V)

U rms
(V)

N/A
Test
voltage
(V)

Required DTI
(mm)

DTI
(mm)

Supplementary information:

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 33 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause
2.10.5

Requirement + Test

Result - Remark

TABLE: Distance through insulation measurements

Distance through insulation (DTI) at/of:

4.3.8

Verdict

U peak
(V)

U rms
(V)

N/A
Test
voltage
(V)

Required DTI
(mm)

TABLE: Batteries

DTI
(mm)
N/A

The tests of 4.3.8 are applicable only when appropriate battery
data is not available
Is it possible to install the battery in a reverse polarity position?
Non-rechargeable batteries
Discharging
Meas.
current

Manuf.
Specs.

Unintentional
charging

Rechargeable batteries
Charging
Meas.
current

Discharging

Manuf.
Specs.

Meas.
current

Manuf.
Specs.

Reversed charging
Meas.
current

Manuf.
Specs.

Max.
current
during
normal
condition
Max.
current
during
fault
condition
Test results:

Verdict

- Chemical leaks
- Explosion of the battery
- Emission of flame or expulsion of molten metal
- Electric strength tests of equipment after completion of tests
Supplementary information:
4.3.8

TABLE: Batteries

Battery category............................................... :

N/A
(Lithium, NiMh, NiCad, Lithium Ion …)

Manufacturer..................................................... :
Type / model..................................................... :
Voltage............................................................... :
Capacity............................................................. :

mAh

Tested and Certified by (incl. Ref. No.).........:
Circuit protection diagram:

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 34 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Verdict

MARKINGS AND INSTRUCTIONS (1.7.12, 1.7.15)
Location of replaceable battery
Language(s) ………………………………….:
Close to the battery ………………………….:
In the servicing instructions …………………:
In the operating instructions ………………..:
4.5

TABLE: Thermal requirements

P

Supply voltage (V) ..............................:

5Vdc

-



Ambient Tmin (C) ................................ :

45.0

-



Ambient Tmax (C) ................................:

45.0

-



Maximum measured temperature T of part/at::

Allowed
Tmax (C)

X8
D1
C25
D8
VD13
D2
D3
Key board
Surface
T1
T2
D9
S1
D15
C2
LCD surface
D2
PCB
Receiver surface
VD1
Ambient
Supplementary information:
Temperature T of winding:
TRF No.: IEC60950_1F

51.6
53.1
64.1
80.8
53.0
61.7
61.1
51.0
49.1
51.4
58.2
61.7
46.6
73.2
53.9
55.3
60.5
67.1
46.6
58.2
45.0
t1 (°C)

R1 ()

t2 (°C)

R2 ()

T (C)

Allowed
Tmax (C)

130.0
130.0
105.0
130.0
130.0
130.0
130.0
85.0
70.0
105.0
130.0
130.0
85.0
130.0
105.0
85.0
130.0
130.
85.0
130.0
Insulatio
n class

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 35 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

-

Result - Remark
-

-

-

-

Verdict

-

-

-

Supplementary information:
4.5.5

TABLE: Ball pressure test of thermoplastic parts
Allowed impression diameter (mm) ........................:

N/A
 2 mm

Part



Test temperature Impression diameter
(mm)
(C)

Supplementary information:
4.7

TABLE: Resistance to fire
Part

Manufacturer of
material

N/A
Type of material

Thickness
(mm)

Flammability
class

Evidence

Supplementary information:
5.1

TABLE: Touch current measurement

Measured between:

Measured
(mA)

N/A
Limit
(mA)

Comments/conditions

supplementary information:
5.2

TABLE: Electric strength tests, impulse tests and voltage surge tests

Test voltage applied between:

Voltage shape Test voltage
(AC, DC,
(V)
impulse, surge)

P
Breakdown
Yes / No

Functional:
-

-

-

-

DC

1000V

No

-

-

-

Basic/supplementary:
Telephone port to handset
Reinforced:
Supplementary information:
5.3

TABLE: Fault condition tests

P

Ambient temperature (C) ........................................:

25°C



Power source for EUT: Manufacturer, model/type,
output rating ...............................................................:

See tabel 1.5.1.



TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 36 of 61

Report No.: RP20170711050

IEC 60950-1/Am1
Clause

Requirement + Test

Result - Remark

Component
No.

Fault

Supply
voltage
(V)

Test
time

Fuse #

Fuse
current
(A)

Opening

BL

5Vdc

130min

-

-

Verdict
Observation

No explosion. 46.9 °C. no fire, no
smoke, No hazard.

Supplementary information:
SC: short-circuit; OC: open-circuit; DF: disconnected fan; BL: blocked openings; LF; locked fan; RP:
reversed polarity.
C.2

TABLE: transformers

Loc.

Tested insulation

Loc.

Tested insulation

N/A
Working
voltage
peak / V

Working
voltage
rms / V

Required
electric
strength

Required
clearance /
mm

Required
distance
thr. insul.

(2.10.3)

Required
creepage
distance /
mm
(2.10.4)

(2.10.2)

(2.10.2)

(5.2)
Test
voltage/
V

Measured
clearance /
mm

Measured
creepage
dist./ mm

Measured
distance
thr. insul. /
mm;
number of
layers

(2.10.5)

supplementary information:

C.2
TABLE: transformers
Transformer

TRF No.: IEC60950_1F

N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 37 of 61

Report No.: RP20170711050

ATTACHMENT TO TEST REPORT IEC 60950-1
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES

Information technology equipment – Safety –
PART 1: GENERAL REQUIREMENTS
Differences according to..................: EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013
Attachment Form No........................ : EU_GD_IEC60950_1F
Attachment Originator......................: SGS Fimko Ltd
Master Attachment............................ : Date 2014-02

EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013 – CENELEC COMMON MODIFICATIONS
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause

Contents

(A2:2013)

General

Requirement + Test

(A1:2010)

General
(A2:2013)

Verdict

Clauses, subclauses, notes, tables and figures which are additional to those in
IEC60950-1 and it´s amendmets are prefixed “Z”

P

Add the following annexes:

P

Annex ZA (normative)

Normative references to international
publications with their corresponding European
publications

Annex ZB (normative)
Annex ZD (informative)

Special national conditions
IEC and CENELEC code designations for
flexible cords

Delete all the “country” notes in the reference document (IEC 60950-1:2005)
according to the following list:
1.4.8 Note 2
1.5.8 Note 2
2.2.3 Note
2.3.2.1 Note 2
2.7.1 Note
3.2.1.1 Note
4.3.6 Note 1 & 2
4.7.3.1Note 2
6
Note 2 & 5
6.2.2 Note
7.1
Note 3
G.2.1 Note 2

General

Result - Remark

1.5.1
1.5.9.4
2.2.4
2.3.4
2.10.3.2
3.2.4
4.7
5.1.7.1
6.1.2.1
6.2.2.1
7.2
Annex H

Note 2 & 3
Note
Note
Note 2
Note 2
Note 3.
Note 4
Note 3 & 4
Note 2
Note 2
Note
Note 2

1.5.7.1
1.7.2.1
2.3.2
2.6.3.3
2.10.5.13
2.5.1
4.7.2.2
5.3.7
6.1.2.2
6.2.2.2
7.3

Note
Note 4, 5 & 6
Note
Note 2 & 3
Note 3
Note 2
Note
Note 1
Note
Note
Note 1 & 2

Delete all the “country” notes in the reference document (IEC 609501:2005/A1:2010) according to the following list:
1.5.7.1 Note

6.1.2.1

Note 2

6.2.2.1 Note 2

EE.3

Note

P

Delete all the “country” notes in the reference document (IEC 609501:2005/A2:2013) according to the following list:
2.7.1
Note *
2.10.3.1
Note 2

P

P

6.2.2.
Note
* Note of secretary: Text of Common Modification remains unchanged.
1.3.Z1

Add the following subclause:

N/A

1.3.Z1 Exposure to excessive sound pressure
The apparatus shall be so designed and
constructed as to present no danger when used for
TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 38 of 61

Report No.: RP20170711050

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause

Requirement + Test

Result - Remark

Verdict

its intended purpose, either in normal operating
conditions or under fault conditions, particularly
providing protection against exposure to excessive
sound pressures from headphones or earphones.
NOTE Z1 A new method of measurement is described in
EN 50332-1, Sound system equipment:
Headphones and earphones associated with portable
audio equipment - Maximum sound pressure level
measurement methodology and limit considerations Part 1: General method for “one package equipment”,
and in EN 50332-2, Sound system equipment:
Headphones and earphones associated with portable
audio equipment - Maximum sound pressure level
measurement methodology and limit considerations Part 2: Guidelines to associate sets with headphones
coming from different manufacturers.

(A12:2011)

N/A

In EN 60950-1:2006/A12:2011
Delete the addition of 1.3.Z1 / EN 60950-1:2006
Delete the definition 1.2.3.Z1 / EN 60950-1:2006
/A1:2010

1.5.1

Add the following NOTE:

(Added info*)

NOTE Z1 The use of certain substances in electrical and
electronic equipment is restricted within the EU: see
Directive 2002/95/EC.
New Directive 2011/65/11 *

1.7.2.1

(A1:2010)

1.7.2.1
(A12.2011)

N/A

In addition, for a PORTABLE SOUND SYSTEM, the
instructions shall include a warning that excessive
sound pressure from earphones and headphones
can cause hearing loss.
In EN 60950-1:2006/A12:2011
Delete NOTE Z1 and the addition for Portable
Sound System.
Add the following clause and annex to the existing
standard and amendments.

N/A

Zx Protection against excessive sound pressure from personal music
players

N/A

TRF No.: IEC60950_1F

N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 39 of 61

Report No.: RP20170711050

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause

Requirement + Test

Result - Remark

Zx.1 General
This sub-clause specifies requirements for
protection against excessive sound pressure from
personal music players that are closely coupled to
the ear. It also specifies requirements for
earphones and headphones intended for use with
personal music players.

Verdict

N/A

A personal music player is a portable equipment
for personal use, that:
is designed to allow the user to listen to
recorded or broadcast sound or video; and
primarily uses headphones or earphones that
can be worn in or on or around the ears; and
allows the user to walk around while in use.
NOTE 1 Examples are hand-held or body-worn portable CD
players, MP3 audio players, mobile phones with MP3 type
features, PDA’s or similar equipment.

A personal music player and earphones or
headphones intended to be used with personal
music players shall comply with the requirements
of this sub-clause.
The requirements in this sub-clause are valid for
music or video mode only.
The requirements do not apply:
while the personal music player is connected
to
an external amplifier; or
while the headphones or earphones are not
used.
NOTE 2 An external amplifier is an amplifier which is not part of
the personal music player or the listening device, but which is
intended to play the music as a standalone music player.

The requirements do not apply to:
hearing aid equipment and professional
equipment;

NOTE 3 Professional equipment is equipment sold through
special sales channels. All products sold through normal
electronics stores are considered not to be professional
equipment.

analogue personal music players (personal
music players without any kind of digital
processing of the sound signal) that are brought
to the market before the end of 2015.

NOTE 4 This exemption has been allowed because this
technology is falling out of use and it is expected that within a
few years it will no longer exist. This exemption will not be
extended to other technologies.

For equipment which is clearly designed or
intended for use by young children, the limits of EN
71-1 apply.
Zx.2 Equipment requirements
No safety provision is required for equipment that
complies with the following:
equipment provided as a package (personal
TRF No.: IEC60950_1F

N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 40 of 61

Report No.: RP20170711050

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause

Requirement + Test

Result - Remark

Verdict

music player with its listening device), where
the acoustic output LAeq,T is ≤ 85 dBA
measured while playing the fixed “programme
simulation noise” as described in EN 50332-1;
and
a personal music player provided with an
analogue electrical output socket for a listening
device, where the electrical output is ≤ 27 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
as described in EN 50332-1.
NOTE 1 Wherever the term acoustic output is used in this
clause, the 30 s A-weighted equivalent sound pressure level
LAeq,T is meant. See also Zx.5 and Annex Zx.

All other equipment shall:
a) protect the user from unintentional acoustic
outputs exceeding those mentioned above; and
b) have a standard acoustic output level not
exceeding those mentioned above, and
automatically return to an output level not
exceeding those mentioned above when the
power is switched off; and
c) provide a means to actively inform the user of
the increased sound pressure when the
equipment is operated with an acoustic output
exceeding those mentioned above. Any means
used shall be acknowledged by the user before
activating a mode of operation which allows for
an acoustic output exceeding those mentioned
above. The acknowledgement does not need to
be repeated more than once every 20 h of
cumulative listening time; and
NOTE 2 Examples of means include visual or audible signals.
Action from the user is always required.
NOTE 3 The 20 h listening time is the accumulative listening
time, independent how often and how long the personal music
player has been switched off.

d) have a warning as specified in Zx.3; and
e) not exceed the following:
1) equipment provided as a package (player
with Its listening device), the acoustic output
shall be ≤ 100 dBA measured while playing the
fixed “programme simulation noise” described
in EN 50332-1; and
2) a personal music player provided with an
analogue electrical output socket for a listening
device, the electrical output shall be ≤ 150 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
described in EN 50332-1.

For music where the average sound pressure (long
term LAeq,T) measured over the duration of the
song is lower than the average produced by the
programme simulation noise, the warning does not
TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 41 of 61

Report No.: RP20170711050

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause

Requirement + Test

Result - Remark

Verdict

need to be given as long as the average sound
pressure of the song is below the basic limit of 85
dBA. In this case T becomes the duration of the
song.

NOTE 4 Classical music typically has an average sound
pressure (long term LAeq,T) which is much lower than the
average programme simulation noise. Therefore, if the player is
capable to analyse the song and compare it with the
programme simulation noise, the warning does not need to be
given as long as the average sound pressure of the song is
below the basic limit of 85 dBA.
For example, if the player is set with the programme simulation
noise to 85 dBA, but the average music level of the song is only
65 dBA, there is no need to give a warning or ask an
acknowledgement as long as the average sound level of the
song is not above the basic limit of 85 dBA.

Zx.3 Warning
The warning shall be placed on the equipment, or
on the packaging, or in the instruction manual and
shall consist of the following:
the symbol of Figure 1 with a minimum
height of
5 mm; and
the following wording, or similar:

N/A

“To prevent possible hearing damage, do not listen
at high volume levels for long periods.”

Figure 1 – Warning label (IEC 60417-6044)
Alternatively, the entire warning may be given
through the equipment display during use, when
the user is asked to acknowledge activation of the
higher level.
Zx.4 Requirements for listening devices (headphones and earphones)
Zx.4.1 Wired listening devices with analogue
input
With 94 dBA sound pressure output LAeq,T, the
input voltage of the fixed “programme simulation
noise” described in EN 50332-2 shall be ≥ 75 mV.

N/A
N/A

This requirement is applicable in any mode where
the headphones can operate (active or
passive), including any available setting (for
example built-in volume level control).
NOTE The values of 94 dBA – 75 mV correspond with 85dBA –
27 mV and 100 dBA – 150 mV.

Zx.4.2 Wired listening devices with digital input
With any playing device playing the fixed
“programme simulation noise” described in EN
TRF No.: IEC60950_1F

N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 42 of 61

Report No.: RP20170711050

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause

Requirement + Test

Result - Remark

Verdict

50332-1 (and respecting the digital interface
standards, where a digital interface standard exists
that specifies the equivalent acoustic level), the
acoustic output LAeq,T of the listening device shall
be ≤ 100 dBA.
This requirement is applicable in any mode where
the headphones can operate, including any
available setting (for example built-in volume level
control, additional sound feature like equalization,
etc.).
NOTE An example of a wired listening device with digital input
is a USB headphone.

Zx.4.3 Wireless listening devices
In wireless mode:
with any playing and transmitting device
playing
the fixed programme simulation noise
described
in EN 50332-1; and
respecting the wireless transmission
standards, where an air interface standard exists
that specifies the equivalent acoustic level; and
with volume and sound settings in the
listening
device (for example built-in volume
level control, additional sound feature like
equalization, etc.) set to the combination of
positions that
maximize the measured
acoustic output for the
abovementioned
programme simulation noise,
the acoustic
output LAeq,T of the listening device
shall be ≤
100 dBA.

N/A

NOTE An example of a wireless listening device is a Bluetooth
headphone.

Zx.5 Measurement methods
Measurements shall be made in accordance with
EN 50332-1 or EN 50332-2 as applicable.
Unless stated otherwise, the time interval T shall
be 30 s.

N/A

NOTE Test method for wireless equipment provided without
listening device should be defined.

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 43 of 61

Report No.: RP20170711050

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause

Requirement + Test

2.7.1

Replace the subclause as follows:

Result - Remark

Verdict

N/A

Basic requirements
To protect against excessive current, short-circuits
and earth faults in PRIMARY CIRCUITS, protective
devices shall be included either as integral parts of
the equipment or as parts of the building
installation, subject to the following, a), b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the requirements
of 5.3 shall be included as parts of the equipment;
b) for components in series with the mains input to
the equipment such as the supply cord, appliance
coupler, r.f.i. filter and switch, short-circuit and
earth fault protection may be provided by
protective devices in the building installation;

2.7.2

c) it is permitted for PLUGGABLE EQUIPMENT
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated overcurrent and
short-circuit protection in the building installation,
provided that the means of protection, e.g. fuses or
circuit breakers, is fully specified in the installation
instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for PLUGGABLE EQUIPMENT
TYPE A the building installation shall be regarded
as providing protection in accordance with the
rating of the wall socket outlet.
This subclause has been declared ‘void’.

N/A

3.2.3

Delete the NOTE in Table 3A, and delete also in
this table the conduit sizes in parentheses.

N/A

3.2.5.1

Replace

N/A

“60245 IEC 53” by “H05 RR-F”;
“60227 IEC 52” by “H03 VV-F or
H03 VVH2-F”;
“60227 IEC 53” by “H05 VV-F or
H05 VVH2-F2”.

In Table 3B, replace the first four lines by the
following:
Up to and including 6 |
Over 6 up to and including 10| (0,75) b)
Over 10 up to and including 16| (1,0) c)

0,75 a) |
1,0 |
1,5
|

In the conditions applicable to Table 3B delete the
words “in some countries” in condition a).
In NOTE 1, applicable to Table 3B, delete the
second sentence.
3.2.5.1

(A2:2013)

NOTE Z1
The harmonised code designations
corresponding to the IEC cord types are given in Annex ZD

TRF No.: IEC60950_1F

N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 44 of 61

Report No.: RP20170711050

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause

Requirement + Test

Result - Remark

3.3.4

In Table 3D, delete the fourth line: conductor sizes
for 10 to 13 A, and replace with the following:

Verdict

N/A

Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to
4
|
Delete the fifth line: conductor sizes for 13 to 16 A
4.3.13.6
(A1:2010)

N/A

Replace the existing NOTE by the following:
NOTE Z1 Attention is drawn to:
1999/519/EC: Council Recommendation on the limitation
of exposure of the general public to electromagnetic
fields 0 Hz to 300 GHz, and
2006/25/EC: Directive on the minimum health and safety
requirements regarding the exposure of workers to risks
arising from physical agents (artifical optical radiation).

Annex H

Standards taking into account mentioned
Recommendation and Directive which demonstrate
compliance with the applicable EU Directive are
indicated in the OJEC.

N/A

Replace the last paragraph of this annex by:

N/A

At any point 10 cm from the surface of the
OPERATOR ACCESS AREA, the dose rate shall
not exceed 1 μSv/h (0,1 mR/h) (see NOTE).
Account is taken of the background level.
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.

Delete NOTE 2.
Bibliography Additional EN standards.



ZA



NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH
THEIR CORRESPONDING EUROPEAN PUBLICATIONS
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)

Clause
1.2.4.1

1.2.13.14
(A11:2009)

1.5.7.1

(A11:2009)

Requirement + Test
In Denmark, certain types of Class I appliances
(see 3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted into
Danish socket-outlets.
In Norway and Sweden, for requirements see
1.7.2.1 and 7.3 of this annex.
In Finland, Norway and Sweden, resistors
bridging BASIC INSULATION in CLASS I PLUGGABLE
EQUIPMENT TYPE A must comply with the
requirements in 1.5.7.1. In addition when a single
resistor is used, the resistor must withstand the
resistor test in 1.5.7.2.

TRF No.: IEC60950_1F

Result - Remark

Verdict
N/A

N/A
N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 45 of 61

Report No.: RP20170711050

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause

Requirement + Test

1.5.8

In Norway, due to the IT power system used (see
annex V, Figure V.7), capacitors are required to be
rated for the applicable line-to-line voltage (230 V).
In Finland, Norway and Sweden, the third dashed
sentence is applicable only to equipment as
defined in 6.1.2.2 of this annex.
In Finland, Norway and Sweden, CLASS I
PLUGGABLE EQUIPMENT TYPE A intended for
connection to other equipment or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and accessible parts, have a
marking stating that the equipment must be
connected to an earthed mains socket-outlet.

1.5.9.4
1.7.2.1

Result - Remark

Verdict
N/A
N/A
N/A

The marking text in the applicable countries shall
be as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”
1.7.2.1

(A11:2009)

In Norway and Sweden, the screen of the cable
distribution system is normally not earthed at the
entrance of the building and there is normally no
equipotential bonding system within the building.
Therefore the protective earthing of the building
installation need to be isolated from the screen of a
cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective earthing of
the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11).”

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 46 of 61

Report No.: RP20170711050

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause

Requirement + Test

Result - Remark

Verdict

NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.

1.7.2.1

(A2:2013)

Translation to Norwegian (the Swedish text will also
be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet
utstyr – og er tilkoplet et kabel-TV nett, kan
forårsake brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet installeres
en galvanisk isolator mellom utstyret og kabel- TV
nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan
utrustning och samtidigt är kopplad till kabel-TV nät
kan i vissa fall medfőra risk főr
brand. Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät
galvanisk isolator finnas mellan utrustningen och
kabel-TV nätet.”
In Denmark, CLASS I PLUGGABLE EQUIPMENT
TYPE A intended for connection to other equipment
or a network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
accessible parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.

N/A

The marking text in Denmark shall be as follows:
In Denmark: “Apparatets stikprop skal tilsluttes en
stikkontakt med jord, som giver forbindelse til
stikproppens jord.”
1.7.5

1.7.5

(A11:2009)

In Denmark, socket-outlets for providing power to
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet shall
be in accordance with Standard Sheet DK 1-1b or
DK 1-5a.
For CLASS II EQUIPMENT the socket outlet shall be in
accordance with Standard Sheet DKA 1-4a.

TRF No.: IEC60950_1F

N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 47 of 61

Report No.: RP20170711050

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause

Requirement + Test

1.7.5

In Denmark, socket-outlets for providing power to
other equipment shall be in accordance with the DS
60884-2-D1:2011.
For class I equipment the following Standard
Sheets are applicable: DK 1-3a, DK 1-1c,
DK 1-1d, DK 1-5a or DK 1-7a, with the exception
for STATIONARY EQUIPMENT where the socketoutlets shall be in accordance with Standard Sheet
DK 1-1b, DK 1-1c, DK 1- 1d or DK 1-5a.
Socket outlets intended for providing power to
Class II apparatus with a rated current of 2,5 A
shall be in accordance with DS 60884-2-D1
standard sheet DKA 1-4a. Other current rating
socket outlets shall be in compliance with by DS
60884-2-D1 Standard Sheet DKA 1-3a or
DKA
1-3b.
Justification
the Heavy Current Regulations, 6c
In Norway, for requirements see 1.7.2.1, 6.1.2.1
and 6.1.2.2 of this annex.
In Finland, Norway and Sweden there are
additional requirements for the insulation. See
6.1.2.1 and 6.1.2.2 of this annex.
In Norway, for requirements see 1.7.2.1, 6.1.2.1
and 6.1.2.2 of this annex.
In the United Kingdom, the current rating of the
circuit shall be taken as 13 A, not 16 A.
In the United Kingdom, to protect against
excessive currents and short-circuits in the
PRIMARY CIRCUIT of DIRECT PLUG-IN
EQUIPMENT, tests according to 5.3 shall be
conducted, using an external protective device
rated 30 A or 32 A. If these tests fail, suitable
protective devices shall be included as integral
parts of the DIRECT PLUG-IN EQUIPMENT, so
that the requirements of 5.3 are met.
In Finland, Norway and Sweden, there are
additional requirements for the insulation, see
6.1.2.1 and 6.1.2.2 of this annex.

(A2:2013)

2.2.4
2.3.2
2.3.4
2.6.3.3
2.7.1

2.10.5.13

TRF No.: IEC60950_1F

Result - Remark

Verdict
N/A

N/A
N/A
N/A
N/A
N/A

N/A

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 48 of 61

Report No.: RP20170711050

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause

Requirement + Test

3.2.1.1

Result - Remark

In Switzerland, supply cords of equipment having
a RATED CURRENT not exceeding 10 A shall be
provided with a plug complying with SEV 1011 or
IEC 60884-1 and one of the following dimension
sheets:
SEV 6532-2.1991 Plug Type 15
250/400 V, 10 A

3P+N+PE

SEV 6533-2.1991 Plug Type 11
250 V, 10 A
SEV 6534-2.1991 Plug Type 12
250 V, 10 A

L+N

Verdict
N/A

L+N+PE

In general, EN 60309 applies for plugs for currents
exceeding 10 A. However, a 16 A plug and socketoutlet system is being introduced in Switzerland,
the plugs of which are according to the following
dimension sheets, published in February 1998:
SEV 5932-2.1998: Plug Type 25 , 3L+N+PE
230/400 V, 16 A
SEV 5933-2.1998:Plug Type 21, L+N, 250 V, 16A
SEV 5934-2.1998: Plug Type 23, L+N+PE
V, 16 A
3.2.1.1

250

In Denmark, supply cords of single-phase
equipment having a rated current not exceeding13
A shall be provided with a plug according to the
Heavy Current Regulations, Section 107-2-D1.

N/A

CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be
used in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
standard sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase
equipment having a RATED CURRENT exceeding
13 A is provided with a supply cord with a plug, this
plug shall be in accordance with the Heavy Current
Regulations, Section 107-2-D1 or EN 60309-2.

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 49 of 61

Report No.: RP20170711050

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause

Requirement + Test

3.2.1.1

In Denmark, supply cords of single-phase
equipment having a rated current not exceeding 13
A shall be provided with a plug according to DS
60884-2-D1.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be
used in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
standard sheet DK 2-1a or DK 2-5a.
If a single-phase equipment having a RATED
CURRENT exceeding 13 A or if a poly-phase
equipment is provided with a supply cord with a
plug, this plug shall be in accordance with the
standard sheets DK 6-1a in DS 60884-2-D1 or
EN 60309-2.
Justification
the Heavy Current Regulations, 6c

N/A

3.2.1.1

In Spain, supply cords of single-phase equipment
having a rated current not exceeding 10 A shall be
provided with a plug according to UNE 20315:1994.

N/A

(A2:2013)

Result - Remark

Verdict

Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be provided
with a plug according to UNE-EN 50075:1993.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be
used in locations where protection against indirect
contact is required according to the wiring rules,
shall be provided with a plug in accordance with
standard UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.
3.2.1.1

In the United Kingdom, apparatus which is fitted
with a flexible cable or cord and is designed to be
connected to a mains socket conforming to BS
1363 by means of that flexible cable or cord and
plug, shall be fitted with a ‘standard plug’ in
accordance with Statutory Instrument 1768:1994 The Plugs and Sockets etc. (Safety) Regulations
1994, unless exempted by those regulations.

N/A

NOTE ‘Standard plug’ is defined in SI 1768:1994 and
essentially means an approved plug conforming to BS
1363 or an approved conversion plug.

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 50 of 61

Report No.: RP20170711050

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause

Requirement + Test

3.2.1.1

Result - Remark

Verdict

In Ireland, apparatus which is fitted with a flexible
cable or cord and is designed to be connected to a
mains socket conforming to I.S. 411 by means of
that flexible cable or cord and plug, shall be fitted
with a 13 A plug in accordance with Statutory
Instrument 525:1997 - National Standards Authority
of Ireland (section 28) (13 A Plugs and Conversion
Adaptors for Domestic Use) Regulations 1997.

N/A

3.2.4

In Switzerland, for requirements see 3.2.1.1 of this
annex.

N/A

3.2.5.1

In the United Kingdom, a power supply cord with
conductor of 1,25 mm2 is allowed for equipment
with a rated current over 10 A and up to and
including 13 A.

N/A

3.3.4

In the United Kingdom, the range of conductor
sizes of flexible cords to be accepted by terminals
for equipment with a RATED CURRENT of over 10
A up to and including 13 A is:

N/A

• 1,25 mm2 to 1,5 mm2 nominal cross-sectional
area.
4.3.6

In the United Kingdom, the torque test is
performed using a socket outlet complying with BS
1363 part 1:1995, including Amendment 1:1997
and Amendment 2:2003 and the plug part of
DIRECT PLUG-IN EQUIPMENT shall be assessed
to BS 1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11,
12.12, 12.13, 12.16 and 12.17, except that the test
of 12.17 is performed at not less than 125 °C.
Where the metal earth pin is replaced by an
Insulated Shutter Opening Device (ISOD), the
requirements of clauses 22.2 and 23 also apply.

N/A

4.3.6

In Ireland, DIRECT PLUG-IN EQUIPMENT is
known as plug similar devices. Such devices shall
comply with Statutory Instrument 526:1997 National Standards Authority of Ireland (Section 28)
(Electrical plugs, plug similar devices and sockets
for domestic use) Regulations, 1997.

N/A

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 51 of 61

Report No.: RP20170711050

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause

Requirement + Test

5.1.7.1

Result - Remark

In Finland, Norway and Sweden TOUCH
CURRENT measurement results exceeding 3,5 mA
r.m.s. are permitted only for the following
equipment:

Verdict
N/A

• STATIONARY PLUGGABLE EQUIPMENT TYPE
A that
is intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential bonding
has been applied, for example, in a
telecommunication centre; and
has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR; and
is provided with instructions for the
installation of that conductor by a SERVICE
PERSON;
• STATIONARY PLUGGABLE EQUIPMENT TYPE
B;
• STATIONARY PERMANENTLY CONNECTED
EQUIPMENT.
6.1.2.1

(A1:2010)

In Finland, Norway and Sweden, add the
following text between the first and second
paragraph of the compliance clause:

N/A

If this insulation is solid, including insulation forming
part of a component, it shall at least consist of
either
two layers of thin sheet material, each of
which shall pass the electric strength test below, or
one layer having a distance through
insulation of at least 0,4 mm, which shall pass the
electric strength test below.
Alternatively for components, there is no distance
through insulation requirements for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below and
in addition
passes the tests and inspection criteria of
2.10.11 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.10 shall be performed using 1,5 kV), and
is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test voltage
of 1,5 kV.

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 52 of 61

Report No.: RP20170711050

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause

Requirement + Test

Result - Remark

Verdict

It is permitted to bridge this insulation with an
optocoupler complying with 2.10.5.4 b).
It is permitted to bridge this insulation with a
capacitor complying with EN 60384-14:2005,
subclass Y2.
A capacitor classified Y3 according to
EN
60384-14:2005, may bridge this insulation under
the following conditions:
the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by EN
60384-14, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in EN
60950-1:2006, 6.2.2.1;
the additional testing shall be performed on
all the test specimens as described in
EN
60384-14:
the impulse test of 2,5 kV is to be performed
before the endurance
test in EN 60384-14, in
the sequence of tests as described in EN 6038414.
6.1.2.2

In Finland, Norway and Sweden, the exclusions
are applicable for PERMANENTLY CONNECTED
EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B
and equipment intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has provision
for a permanently connected PROTECTIVE
EARTHING CONDUCTOR and is provided with
instructions for the installation of that conductor by
a SERVICE PERSON.

N/A

7.2

In Finland, Norway and Sweden, for requirements
see 6.1.2.1 and 6.1.2.2 of this annex.

N/A

The term TELECOMMUNICATION NETWORK in
6.1.2 being replaced by the term CABLE
DISTRIBUTION SYSTEM.
7.3

In Norway and Sweden, for requirements see
1.2.13.14 and 1.7.2.1 of this annex.

N/A

7.3

In Norway, for installation conditions see EN
60728-11:2005.

N/A

(A11:2009)
(A11:2009)

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 53 of 61

Report No.: RP20170711050

Annex ZD
(informative)
IEC and CENELEC code designations for flexible cords
Type of flexible cord
Code designations
IEC
CENELEC
PVC insulated cords
Flat twin tinsel cord
60227 IEC 41
H03VH-Y
Light polyvinyl chloride sheathed flexible cord
60227 IEC 52
H03VV-F
H03VVH2-F
Ordinary polyvinyl chloride sheathed flexible cord
60277 IEC 53
H05VV-F
H05VVH2-F
Rubber insulated cords
Braided cord
60245 IEC 51
H03RT-F
Ordinary tough rubber sheathed flexible cord
60245 IEC 53
H05RR-F
Ordinary polychloroprene sheathed flexible cord
60245 IEC 57
H05RN-F
Heavy polychloroprene sheathed flexible cord
60245 IEC 66
H07RN-F
Cords having high flexibility
Rubber insulated and sheathed cord
60245 IEC 86
H03RR-H
Rubber insulated, crosslinked PVC sheathed cord
60245 IEC 87
H03RV4-H
Crosslinked PVC insulated and sheathed cord
60245 IEC 88
H03V4V4-H

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 54 of 61

Report No. : RP20170711050

EUT Photo

The overall view of EUT

The rear view of EUT
TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 55 of 61

Report No. : RP20170711050

The inside view of EUT

The top view of KEY PCB

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 56 of 61

Report No. : RP20170711050

The rear view of KEY PCB

The top view of VIP PCB
TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 57 of 61

Report No. : RP20170711050

The rear view of VIP PCB

The top view of LCD

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 58 of 61

Report No. : RP20170711050

The rear view of LCD

All the view of loudspeaker

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 59 of 61

Report No. : RP20170711050

The inside view of handset

Adapter
TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 60 of 61

Report No. : RP20170711050

Adapter

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.

Page 61 of 61

Report No. : RP20170711050

TEST INSTRUMENTS REFERENCE LIST
Instr.

Instrument

Instrument

Range Used

Code

I.D.

Type

Or ***
Input: 200/240Vac,4763Hz, 5000VA.
Output:0-60V,0-46A,
2760W.

Maker and Model **

Calibration Date
Last

Due

2016/12/05

2017/12/05

SE02

A00017328

DC Power
Supply

SE17

A00017339

Test Finger

Dimensions please refer
ED.D / UFP-01
to GB4943 Fig.2A

2016/11/07

2017/11/07

SE20

SE20

Test Pin

Dimensions please refer
GZ-ZLT / SYX-1
to GB4943 Fig.2B

2016/12/09

2017/12/09

SE36

AG001

Electronic Stop
Watch

Min:0.01s

TF / PC396

2017/04/19

2018/04/19

A10054895

AC:5KV,40mA max.
Electrical Safety DC:6KV, 12mA max.
Analyzer
GB:30A, 0.21ohm
max(0~360s)

Chroma / 19032

2016/11/14

2017/11/14

A22760117

Four Channels,
Bandwidth:500M
max Input Range::
400Vpeak(or CAT
I150Vrms/CAT II
Digital Phosphor 100Vrms, BNC
Oscilloscope
Input(1MΩ)),
5Vrms and
Vpeak≤±30V(BNC
Input(50Ω))
Input
Impedance:1MΩ,50Ω

Tektronix / TDS3034C

2016/11/04

2017/11/04

K type:-267℃ -260℃

Agilent / 34901A

2017/04/05

2018/04/05

Digiton Force
Gauge

Max.Scale: 1000N

AIGU / ZP-1000

2016/08/03

2017/08/03

Dropping wood

Hardwood thick:13mm
Each of two plywood
ETR / SE102
thick:19mm~20mm

N/A

N/A

SE42

SE83

SE85-01

20-Channel
1-A22804814 Armature
Multiplexer

SE93-01

SE93-01

SE102

SE102

Chroma / 6202F-60

--- End of Report ---

TRF No.: IEC60950_1F

Shenzhen Zoom Rel Testing Technology Co., Ltd.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Page Count                      : 61
Author                          : JMW
Comments                        : 
Company                         : 
Create Date                     : 2017:07:21 17:20:37+09:20
Creator                         : WPS Office
Keywords                        : TRF, -, CB, Scheme
Modify Date                     : 2017:07:21 17:20:37+09:20
Producer                        : 
Source Modified                 : D:20170721172037+09'20'
Subject                         : IEC/EN
Title                           : TEST REPORT FORM TEMPLATE
Trapped                         : false
EXIF Metadata provided by EXIF.tools

Navigation menu