YEON TECHNOLOGIES YRU150 UHF RFID Reader User Manual

YEON TECHNOLOGIES CO., LTD. UHF RFID Reader Users Manual

Users Manual

            YRU-150 User Manuel installation   and   operations guide
                              YRU-150 User Manuel installation and operations guide Ver.0.2 www.yeon.com.tw 版權所有,翻版必究 2 Catalog  A. WARNING .................................................................................................................................................... 3 B. INTRODUCTION ........................................................................................................................................ 4 C. READER SPEC. ........................................................................................................................................... 4 D. CONNECTOR DESCRIPTION ................................................................................................................. 5 E. DEMO SOFTWARE DESCRIPTION ....................................................................................................... 7
                              YRU-150 User Manuel installation and operations guide Ver.0.2 www.yeon.com.tw 版權所有,翻版必究 3  A.  Warning Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.  FCC Caution: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
                              YRU-150 User Manuel installation and operations guide Ver.0.2 www.yeon.com.tw 版權所有,翻版必究 4   B.  Introduction UHF RFID EPC C1G2 Reader Features  Compatible with ISO-18000-6C  2 / 4 Antenna Port (SMA Jack)  Support Ethernet, RS232, RS485, USB Interface   Support GPIO function(4 input & 4 output)  Average power consumption: under 420mA at 12V  RF out MAX=25dBm  C.  Reader Spec. Electrical characteristics   1.2.1 DC characteristics Parameter Symbol Min. Typ. Max. Unit Average operating current Ioc - 320 - mA Standby current Isb - 170 - mA Peak current Ipea k - 420 - mA  1.2.2 AC characteristics Parameter Symbol Min. Typ. Max. Unit RF Output Frequency Fc 922 - 928 Mhz RF Output Power Pout   - 25 dBm RF Transmission setup time TRF_OUT - - 0.5 ms RF Frequency error Ferror - - 1000 ppm Transmit data rate TRate - 26K - bps   Modulation ASK Modulation Type 90% normally Data Coding PIE Demodulation ASK Download data rate DRate - 40K - bps Data encoding FM0
                              YRU-150 User Manuel installation and operations guide Ver.0.2 www.yeon.com.tw 版權所有,翻版必究 5  D.  Connector Description 4 SMA Antenna port  Photo1 Antenna Port & LED   Interface
                              YRU-150 User Manuel installation and operations guide Ver.0.2 www.yeon.com.tw 版權所有,翻版必究 6 Photo2 DC Power Jack & Connect Interface. (Default configuration is RJ45)  GPIO Connector  Photo3    PIN No. Pin name Description PIN No. Pin name Description 1 GPO1 NC1 13 GPI1 GPI1 2 NO1 14 GPI2 GPI2 3 COM1 15 GND GND1 4 GPO2 NC2 16 GPI3 GPI3 5 NO2 17 GPI4 GPI4 6 COM2 18 RST Reset 7 GPO3 NC3 19 RS485 RS485+ 8 NO3 20 RS485- 9 COM3 21 12V DC12V 10 GPO4 NC4 22 WD WD0 11 NO4 23 WD1 12 COM4 24 GND GND2
                              YRU-150 User Manuel installation and operations guide Ver.0.2 www.yeon.com.tw 版權所有,翻版必究 7 E.  DEMO Software Description  Connect Reader & Read EPC 1. Auto select communication port  2. RF Power setting  Action: Select Set bottom
                              YRU-150 User Manuel installation and operations guide Ver.0.2 www.yeon.com.tw 版權所有,翻版必究 8  Action: Select Drop-down menu, ex: 25dBm  3. Read EPC ID  Action: Select EPC (U) bottom and check Multi & Cont.
                              YRU-150 User Manuel installation and operations guide Ver.0.2 www.yeon.com.tw 版權所有,翻版必究 9  Engineering model  1. Select Reader Setting and press Set bottom to enter engineering model  2. Frequency calibration 2.1 Select test Region《1》. 2.2 Select test frequency《2》and press Set to completed. 2.3 Key in the measurement value by Spectrum Analyzer《3》and press Adjust to completed. 2.4 Adjust manually《4》, press “+” & “-” bottom to calibration. 3. Power setting Select power value《5》 and press Set to completed. 4. Carry measurement 4.1 Select “Carry” and chose frequency《6》, press Set bottom to running test. 4.2 Select “Rx” and chose frequency《6》, press Set bottom to running test. 5. Modulation testing Press “Run” to test modulation test.

Navigation menu