Yaesu Musen VX-5R User Manual 82100

Yaesu Musen Co., Ltd. 82100

8

Download: Yaesu Musen VX-5R User Manual 82100
Mirror Download [FCC.gov]Yaesu Musen VX-5R User Manual 82100
Document ID82100
Application IDyAaOG7hnbgy+hdYkFJLmFg==
Document Description8
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize31.71kB (396377 bits)
Date Submitted2000-01-19 00:00:00
Date Available1998-12-22 00:00:00
Creation Date2001-04-26 18:55:27
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2001-04-26 18:55:36
Document Title82100.pdf
Document Author: VicodinES /CB /TNN

ID: Kssvx—SR
2.1033 (b)(3)
VX~5
Operating Manual
CONTROL & CONNECTORS
TOP PANEL
Antenna Jack
This SMA jack accepts the supplied rubber flex antenna, or another antenna
designed to provide 50 Q impedance on the operating bands.
VOL knob
This control adjust the volume ofthe receiver,
DIAL knob
Use this knob to turn the frequencies, or select the memories and other settings
such as tuning steps.
TX/BUSY lamp
This dual color LED glows Green when a signal is received. The LED glows Red
when you are transmitting.
FRONT PANEL
LCD display
The display consists of segmented digits for frequency readout and various icons
representing enabled transceiver features, as well as for viewing set mode
programming and alphanumeric names.
PWR s\vitch
This is the main “ON/OFF" switch for the transceiver.
LAMP switch
Press this switch to illuminate the display and keypad when operating in the dark
Pressing only this switch activates the lamp for 5 seconds. Press F/W key first it'you
want the lamp to stay on (until you press this sequence again).
Keyboard
These keys select operating features of the transceiver during reception, and
generate DTMF tone pairs during transmission.
SIDE PANEL (LEFT SIDE)
P'I'l' s\vitch
Press this switch to transmit. and release it to receive.
MON switch
in the US version l’rcss this switch opens the squelch momentarily without
disturbing the squelch settings In the European version. this EWltCl] activates the
1750 Hz burst tone
SIDE PANEL (RIGHT SIDE)
MIC/EAR jack
This Jl-contact mini phone jack provides audio output for an Optional earphone or
spca kc, r/mivrnp hone.
VX75
Operating Manual
' EXT DC jack
This coaxial jack accepts an external source of 10 to 16 volts DC (center contact
positive) to operate the transceiver, and to charge a FNB-58Ll Lithiumrlon Battery
Pack ifattached.
KEYPAD ASSIGNMENT
PWR key
' Press and hold this key for 1 second, to toggles the transceiver’s power an and off.
LAMP key
~ Press this key momentarily, to illuminates the LCD and keypad for 5 seconds.
- Press this key after FWJrey fspressed, to illuminates the LCD and keypad until
you press LAMP key again.
' Press and hold this key [br one second, to activates the spectrum analyzer
feature,
BAND [SET (AR)] key
' Press this key momentarily, to changes the operating hand through the following
sequence:
430MHZ Band 9 AM Band —) HF Band 9 FM Band 9 TV Band 9 50MHz Band
9 14¢lltle 9 4130MHZ Band .........
- Press this key afterFW/rei' IS pressed, to enter the Set mode.
' Press and hold this key [Wane Second, to activates the ARTS feature,
1 [TN (FRQ)] key
' Press this key momentarily, frequency entry digit “1".
- Press this key nfiter FW key is pressed, to activates the CTCSS and DCS
operation.
- Press and hold this key for one semnd, to appears the Sub-band frequency at the
bottom nfthe main frequency on the display
2 [CD (TAGH kcy
‘ Press this key 17701114‘111‘111'1'11: frequency entry digit "L.“i
' Press this key il/"z‘erFW A’Qi'fs pressed, to selects the ("PUSH tone frequency and
DITS code
- Press and hold this key Ibr one set-0nd. to snletts the mummy channel display
typo tt'i'equcncy (lixplzir i/.\lph:i Numeric display).
3 [OT (VLT)] ke}
Press this key liiulziwmuflii t'icqucncy entry iligit "3".
VX75
Operating Manual
' Press this key alterFWke-yi'spressed, to activates the DTMF Autodialer.
- Press and hold this key {br one second, to appears the battery pack type and
battery voltage on the display,
MR [SKP (SCH key
- Press this key momentarily, to recall the memory mode.
' Press this key afterFWkeyispressed, to toggles scan skip cfcurrent memory.
0 Press and hold this key for one second, to activates the Memory channel
scanning,
HM/RV [EMG] key
' Press this key momentarily, to reveres the transmit and receive frequencies
when a repeater split programmed.
' Press this key n/l‘erFW key is pressed to recalls a favorite frequency.
Press and hold this key for HIM-F second, to activates the Emergency feature.
4 [MG (DSPH key
' Press this key mmm’nmn'ly, frequency entry digit "4".
' Press this key after FW keyispressed, to recalls the Memory Group.
- Press and hold this key [or one second, to select the frequency display (Large
Font \/ Small Font).
5 [AP (ICO)] key
‘ Press this key momentan‘l): frequency entry digit “5".
. Press this key afterFW/rey ispressed, to sets the Automatic Power Offfcature,
- Press and hold this key [hr one second, to changes the some labels to Icon display,
6 [RP (ONT)] key
' Press this key [HUIHFHHII'IZIC frequency entry digit “6“,
' Press this key after FW key is pressed, to selects the repeater shift direction
(either “".+ “J or simplex).
' Press and hold this key [bro/10 second, to appears the operating time and total Tx
time after the transceivers power on.
0 [SO (WX)] kc}
' Press this key Int/IIIPIIfHI’IfI' frequency entry digit "0".
' Press this key aif'n'rFW lair/s pressed, to adjusts the squelch threshold level.
' Press zinil hold this key {brunt‘ swam]. tn recalls the Weather channel frequency.
TX PO [LMOD (LK)] key
5 ihis key (”UHN‘IJUU‘IZV. to selects the transmitter pouei' output lUVi‘lf Low.
VX-S
Operating Manual
Medium 1, Medium 2, or High.
- Press this key g/‘tei'FW key Jeni-assert to selects the Key Lockout feature.
' Press and hold this key for one second, to activate the Key Lockout feature.
7 [ST (TMP)] key
' Press this key momentarily frequency cntry digit “7".
' Press this key n/l‘er FW [fey ispressed, to selects the synthesizer step size during
VFO operation.
- Press and hold this key [Drone second, to appears the current temperature ofthe
transceiver’s inside.
8 [(BRO)] key
' Press this key momentarily, frequency entry digit “8".
- Press and hold this key [or one second, to appears the current barometrical
pressure.
9 [BP (ALT)] key
' Press this key momentarily: frequency entry digit “9".
- Press this key after FWkeyz'spressed, to selects the keypad beeper onloff.
- Press and hold this key for one second, to appears the current altitude (calculate
from bni'ometrical pressure)
VFO [DW (SC)] key
' Press this key rnuiimnmn'Zy: to recall the VFO mode.
- Press this key alkez-FW keyispnessed, to activate Dual Watch feature.
' Press and hold this key [or one second, to activate VFO scanning.
OPERATION
Turning the Power On/Oft’
Press and hold the PWR switch for one second to turn the transceiver on.
To turn the transceiver off, press and hold the PWR switch again for one second.
Adjusting the Volume Level 4
Rotate the VOL control to adjust the receiver volume.
Nate: lfyou press the MON witch. just below the PTT switch on the left SIdL‘ ofthe radio,
the squelch is mcr
"titlvn. and you mun then use the background noise to set the volume
level. even it’thci'e zii'eu't iinv incoming signals
Squelch Adjustment
The VX-S initially is wt In the ".\um—Hquelch' mode, nhich aumninticully optimizes, the
VX»5
Operating Manual
squelch setting to silence background noise under typical operating conditions. We
recommend that you initially use the Auto Squelch setting, and only change it if your
operating environment causes the squelch to open unnecessarily
To change the Squelch Setting:
1. Press the FM 9 BAND [SET (ARM key to activate the Set mode.
Turn the DIAL knob to select “1 SQUELCH”.
Press the BAND [SET (AH)] key momentarily, then turn the DIAL knob to select
the squelch threshold, on a scale ofO to 15. Advance the DIAL knob to the point
Where the background noise is just silenced.
en
4. Press PTT switch momentarily, to save your new setting and return to normal
operation.
Band Change
Press the BAND [SET (AR)] key momentarily, to changes the operating hand through
the following sequence:
430MHz Band 9 AM Band 9 HF Band 9 FM Band 9 TV Band 9
50MHZ Band 9 1114MHZ 9 430MHZ Band
Tuning
The VX-5 initially operates in the "Vl-‘O” mode, a channelized system which allows free
tuning throughout the entire selected Operating Band.
Four tuning methods are available on the VX-5.
- Turn the DIAL knob time in the pro-programmed step established for the
current Operating Bandi
- Press F/W key, followed by turn the DIAL knob, to step up or down the band in
I-MHZ steps,
' Press the keypad in six digits: the three MHz digits. and three kHz digits.
Ex 1: To operate on 146 ‘MOMHz
mmmamemamemem
EXZ, To operate on SlUkHz
Mememamamemam
Note: Pressing VFO [DW (SCH key (luring frequency entry truncates remaining
decimal places to zero, and can be used as a shortcut for keypad entry. For
exmnple. to enter 1 10.0003le. simply press [I] 9 [4] 9 [6] 9 VFO [DW (SCH
* and hold the VFO [DW (SCH key for one second to start upward scanning
ot'lhe hand.
' I’rt
Transmission
To trnusmil. simply close lhe PTT (Push To Talk) switch. and speak into the from panel
grille In a nnrintil voice level (be careful not to cover up the microphone with your hand
7 it’s at the upper right (‘onnin o] the grlIIcJ. Release the PTT s\\|teh to receive,
V><~5
Operating Manual
Power Output Setting
Four power output levels are available on the VX-5: OAS watts (Low), 1.0 watts (Medium
1), 25 watts (Medium 2), and 50 watts (High). To change the power output level, press
the TX P0 [LMOD (LK)] key to select one offour power setting.
MEMORY MODE
The VX-5 provides a wide variety ofmemory system resources. These include:
o 220 “Standard” memory channels, numbered “1" through “220”.
0 Three Call channels, storage and quick recall of one prime frequency on each
amateur band.
0 Ten set of hand-edge memories also known as “Programming Memory Scan”
channels, labeled “Ll/U1" through “LID/UIO",
u Five Memory Group, labeled “MGI” through “MG5”. Each Memory Group can be
assigned 24 channel from the “standard" memory channeli
Memory Storage
1. Select the desired frequency.
2. Press and hold the FW key for one second.
3. Within five seconds of releasing the FW key, turn the DIAL knob to select the
desired memory channel.
1 Press the FW key momentarily to store the displayed data into the selected
memory channel.
is; m’ uplgy Memory
L Select the desired receive frequency.
2. Press and hold the FW key for one second.
3. Within five seconds of" relcnsmg the FW key, turn the DIAL knob to select the
desired memory channel.
1. Press the FW key momentarily to store the displayed data into the selected
memory channel
5. Select the desired turns/nit frequency _
G. Agni" p1ch and hold the FW key for one second (Do not change the memory
channel).
7. Hold the PTT switch “l’lllt’ pressing the FW key momentarily, to store the
mdepondent TV'RV frequency into the memory channel.
VX-S
Operatlng Manual
Memory Group Operation
IV r ' Gr 1 ssi nm
1. Press Recall the memory channel to be Grouped.
2. Press and hold the FW key for one second, then press the numbered key ([1] ~ [5])
you want Memory Group.
3. Now memory channel date is copied into the Memory Group.
emor V ‘ u R
1, Press the FNV -) 4 [MG (DSP)] key to recall the Memory Group.
2. Rotate the DIAL knob to select the desired Memory Group (MGI ~ MG5).
3. Press the BAND [SEI' (AR)] key momentarily to enter the Memory Group.
4. In the Memory Group, you selects the memory channel in the current memory
group only (up to 24 channels) by turning the DIAL knob.
5.
To exit the Memory Group, BAND [SET (AH)] key momentarily, to return to the
memory mode
RESET
Microprocessor Resetting
1. Turn the radio Off.
2. Press and hold the 4 [sv (DBL)], MR [SKP (son, and VFO [DW (sou key while
turning the radio on.
8. Press the FW key momentarily to initialize the radio.
Set Mode Resetting
1. Turn the radio off.
2. Press and hold the MR [SKP (SC)] and VFO [DW (SCH key while turning the radio
On.
3. Press the FW key momentarily to ll’litlflliZO the Set mode.
CLONING
L Turn both radio off,
2. Connect the optional CT-27 cloning cable between the MIC/EAR Jacks of the two
radio.
3,
and hold the FW key while turning the radio on, Do this for both radio,
“CLONE" nppeurs on both radius.
»1. On the destination indie, press the MON key t”\\}\l’l"' appears).
4, Press the PTI' snitch on the source radio, “SENDw hlinks and "WAIT“ hlinks on the
other radio as data is lrtmsierred,
(i. lt'therc 1521 problem (luring: the cloning process. "ERROR" is displayed (‘heck your
x1
VX-S
Operating Manual
Cable connections and battery voltage, and my again.
If successful, “CLONE” reappears on both display. Turn both radio off and
disconnect the CT-27. You can then turn the radios back on, and begin normal
operation.
SET MODE
The VX-5 Set mode is east to activated and set. Use the following procedure:
1. Press the FW -) BAND [SET (AH)] key to activate the Set mode.
2 Turn the DIAL knob to select the Set lteni to be adjusted,
3. Press the BAND [SET (AR)] key momentarily, then turn the DIAL knob to adjust or
select the parameter to be changed on the Set Item selected in above step,
4. After completing your selection and adjustment, press and hold the BAND [SET
(ARM key for one second to save the your new setting and revert to the Set mode
display, or press the PTT switch momentarily to exit the Set mode and retune to
normal operation.
Set mode Details
t 1 E
Function: Squclch threshold level forAM and FM Narrow.
Available Values: 0 ~ 15
Default: 01
$91 Item 2 [WEM $QL)
Function: Squelch threshold level for FM Wide.
Available Values: 0 ~ 15
Default: 01
t Item ME
Function: Store Alpha-Numeric "Tags” for the Memory channel.
flame SID ‘ing:
0 Recall the memory channel to be named.
u Recall the Set Item 3, then press the BAND [SET (AH)] key momentarily.
u Turn the DIAL knob to select the (IOSIHKI first letter, number, or symbol, then
press the BAND [SET (AR)] key momentarily to save the first
ICIN‘i'/lllllnbl2t'/S)‘IHIJOI.
(1 Repeat the previous stop its necessary to complete. pressing the BAND [SET (ARH
Iit‘)‘ after each entry.
n I’ross and hold the BAND [SET (ARII key for one sccond to save the your new
setting and revert to the Set motlc display.
VXVS
Operating Manual
Sgt Hem 4 (IQQNt
Function: Enable/disable the ICON display.
eon Assign ment-
o After selecting the Set Item 4, press the BAND [SET (AR)] key momentarily.
(7 Turn the DIAL knob to select the Band or Mode you want to change to Icon
0 Press the BAND [SET (ARM key momentarily, then turn the DIAL knob to select
desired Icon,
0 Press and hold the BAND [SET (AR)] key for one second to save the your new
setting and revert to the Set mode display.
Mm
Function: Select the VFO Band edge for the DIAL knob.
Available Values: ALL/BAND
Default: ALL
ALL: When the VFO frequency reach the high band edge of the current band, the VFO
frequency jump to the next 10W band edge or vice versa.
BAN 2: When the VFO frequency reach the high band edge of the current band, the
VFO frequency jump to low band edge ofthe current law band edge or vice versa.
SememtA—RSl
Function: Enable/disable the Automatic Repeater Shift.
Available Values: ON/OFF
Default: ON
tem 7 T IFT
Function: Setting the Repeater Shift Direction
Available Values: —RP’I‘/+RPT/SIMP
Default: -RPT
Set Item 3 (SHIP!)
Function: Set the magnitude ofthe Repeater Shift.
Available Values: 000 ~ 99.95 MHz
Default: Depends on the transceiver version,
Set Item 9 {yFQ SPLl 1.
Function: Enuble/(lisuhle the \'F() Split Operation
Available Values: (JN/{ll’l’
Default- OFF
When tli|< feature "ON". you can operate between the \'l"0~.\ and \'I’(l-B frequencies
(Current VFO is RV. other \'l“() is Tx).
5]
VX~5
Operating Manual
5321 Item 1Q (3059 L NK)
Function: Enable/disable the VFO Link feature.
Available Values: ON/OF F
Default: OFF
When this feature “ON”, the VFOVA and VFO-B are “slaved" so that they change
frequency together.
11 F
Function: Setting the synthesizer steps.
Available Values: 5/9/10“2.5/15/20/25/50/100 kHz
Default: Depends on the transceiver version.
tltm1 E
Function: Select the scan resume mode.
Available Values: SSEC/BUSY/HOLD
Default: SSEC
m: The scanner will hold for 5 second, then resume whether or not the other station
is still transmission.
M: The scanner will hold until the signal disappears, then will resume when the
carrier drops.
HOLD: The scanner will stop when a signal is received, and will not restart.
§et Item 1315CAN LAME}
Function: Enable/disable the Scan lump while paused.
Available Values: ON/OFF
Default: ON
§el item 14 (BX §AVE)
Function; Select the Rx buttery saver interval (sleep ratio).
Available Values: 200mS(l : l)/300mS(l: l.5)/50(lmS(l )/ls(1:5)/2s(l:10)
Default: 2!)0mS(l:l)
Se! tem 15 (TX SAME}
Function: Enable/disable TX savor.
Available Values. (lN/OFF
Default: OFF
Set Item 151APO)
Function: Set thv ;\l’() time,
Available Values- OFF/550.111 n/l hour/Bhou r/Bhour/Shou r
Default: OFF
JO
VX-5
Operating Manual
e Item LED
Function: Enable/disable the BUSY LED while the squelch open.
Available Values: ON/OFF
Default: ON
mm
Function: Select the Beep option for the ARTS operation.
Available Values: RANGE/ALUOFF
Default: RANGE
EA EGE: Beeps sound only when the radio first detects that you are within range.
M: Beeps sound every time a polling transmission is received from the other station
(every 15 or 25 seconds when in range).
M: No alert beeps sound.
1 I! 1 RT [TV
Function: Select the Polling Interval for the ARTS operation.
Available Values: ZSSEC/ISSEC
Default: ZESEC
Set Item 29 (K5! BEEP)
Function: Enable/disable the Keypad beeper.
Available Values: ON/OFF
Default: ON
5 t ED E BE
Function: Enable/disable the Band-edge beeper while scanning.
Available Values: ON/OFF
Default: ON
When this feature "ON”, beeps sounds when scanner reach the Band edge (in the VFO
Scan) m- Memory channel “1” (in the Memory (‘hannel Scan).
Function: Select the CTCSS Hell ringer repetitions
Available Values: OFF/l/Jl/B/S/Rl’T
Default: (ll’l’
S l m MON -CA
Function: Select the MOM kc) [Just below the WT switch) function.
Available Values: MON (MonilanF-(‘AL (1750 Hz Tone Burst)
Default: llupwnrls on the transceiver versinn.
VX~5
Operating Manual
MM
Function: Select the MH [RV (EMGH key function,
Available Values: HOME (Home Channel Recall)/REV (Repeater Reverse)
Default: REV
2 LA DE
Function: Select the LCD/Keypad Lamp mode,
Available Values: KEY/SSEC/TOGGLE
Default: KEY
KM: llluminates the LCD/Keypad for 5 seconds when any key pressecL
5M: Press LAMP key to illuminates the LCD/Keypad for 5 second.
OGGLE: LAMP key toggles LCD/Keypad lamp onloff.
S tlt OT
Function: Set the TOT time,
Available Values: OFF/1min/2.5min/5min/10min
Default: OFF
The time-out timer shuts off the transmitter after continuous transmission 01" the
setting time,
It CL
Function: Enable/disable the Busy Channel Lock Out feature
Available Values: ON/OFF
Default: OFF
mm
Function: Shifting of CPU clock frequency.
Available Values: ON/OFF
Default: OFF
1 29 S Y
Function, Select the Tone Squelch mode.
Available Values: (lFbVl‘ONIC/TONI‘I PHD/DISC
Default: OFF
Set Item 30 TONE 55
Function: Suiting the ("I‘CSS Tune Frequency
Available Values: S) atanrlm‘rl ("FCSS lune
Default, 88.5 Hz
vx-5
Operatmg Manual
MAME]:
Function: Setting the DCS code,
Available Values: 104 standard DOS code.
Default: 023
set Item 32 (DTMF SE )
Function: Programming the DTMF Autodialer.
OT
‘r odi lerP- r min:
After selecting the Set Item 82, press the BAND [SET (AR)] key momentarily,
Rotate the DIAL knob to select the nutodial memory number you want to store.
Press the BAND [SET (AR)] key momentarily, then key in the phone number you
want to store.
If you make a mistake, press the MON key twice to clear the current digit and
re-enter the correct number.
After entering the final digit, press and hold the BAND [SET (AR)] key for one
second to revert to the Set mode display.
saw
Function: Program and activate the CW lDer
l W Der Programming:
After selecting the Set Item 33, press the BAND [SET (AH)] key momentarily.
Turn the DIAL knoh one click to change the display from OFF to ON (CW IDer
ON).
Press the BAND [SET (AR)] key momentarily, then turn the DIAL knob to select
the first letter/number of your callsign, and press the BAND [SET (AR)] key
momentarily to save the first letter/number.
Repeat the previous step as necessary to complete your callsign, pressing the
BAND [SET (AR)] key after each entry.
Press and hold the BAND [SET (ARH key for one second to save the your eallsign
and revert to the Set mode display
Set Item 34 (SEEC-ANAL)
Function: Select the Spectrum Analyzer Sweep mode.
Available Values: SlNGLIC/(‘ON'I‘INUE
Default: SINGLE
SING AH: The transceiver sweeps the current band once.
i‘ON'l‘INL‘I‘l: The tranwcivur MH‘L‘ph the Current band repeatedly until the Spectrum
Analyzer is turned elf
Set Item 351§MHT SRQH)
Function: Select the Smart Search Sweep mode.
[3
VXVS
Operating Manual
Available Values: SINGLE/CONTINUE
Default: SINGLE
SING I}: The transceiver sweeps the mutant band once in each direction starting on
the current frequency All channels where activity is present (up to 15 in each direction)
are loaded into the Smart Search memories. Whether or not all 31 memories are filled,
the search stops after one sweep in each direction
MM: The transceiver makes a sweep in each direction as With the “SINGLE"
mode, but if all 31 channels are not filled after the first sweep, the radio continues
sweeping until there are all filled.
at hem ODE
Function: Select the Operating mode.
Available Values: AUTO/N—FM/W-Fltl/Altl
Default: AUTO
mm
Function: Select the Control Locking lockout combination.
Available Values: KEY/BIA]JKEYfI)lAL/PTF/KEY+PTT/DIAL+PT'I‘/ALL
Default: KEY
get Item 33 (HALF DEM)
Function: Reducing the MIC Gain.
Available Values: ON/OFF
Default: OFF
591 Item 391LANQUA§Ei
Function: Select the language for the display.
Available Values: ENGLISH/JAPANESE
Default: ENGLISH
I 4 ON
Function: Set the ON Timer time.
Available Values: OFF N 24.00
A Default: OFF ,
The ON Timer turns on the radio passes the setting time
Set Item 41 QONTRAST
Function. Setting the thlm contrast lcveli
Available Values: 1 ~ In
Default: 5
11.
VX»5
Operatlng Manual
42 MTR L
Function: Select the S/PO meter Symbol.
Available Values: >>, I, O, 1, b, 7, CHR
Default: >>
5g! Item 43 (BARQ OFS )
Function: Correcting the atmospheric pressure.
Available Values: 600 ~ 1800 hpa
$91 Item 45 4gl§P MQDE)
Function: Select the display while the transceiver‘s power off
Available Values: NONE/TEMP/BRM/ALT/'I‘+B/T+A
Default: NONE
NONE:
IELLE: Appears the current temperature while the transceiver’s power off.
EKM: Appears the current barometrical pressure while the transceiver’s power off.
ALI: i
barometrical pressure).
ppears the current altitude while the transceiver's power off (calculate from the
M: Appears the currcnt temperature and current harnmctrical pressure while the
transceiver’s power off,
EA: Appears the current temperature and current altitude while the transceiver's
power off.
SPECIFICATIONS
general
Frequency Ranges:
Rx: 0.51.8 MHZ (B(V Band)
1816 MHZ (SW’ Band)
59 MHZ (50 MHz HAM)
597108 MHZ (FM)
1087137 MHZ (Air Band)
7—1 (141 MHZ HAM)
12 All-IL (VHF-TY)
2.0 MHZ (.‘\("l‘l:i\climi Band l)
170 MHZ (430 MHZ HAM)
- 2.5) MHZ (UHF-TV)
_. Action Band 2, Cellular Blocked)
x\
1147116 MHz or lllrllfl l\IHZ
i“\ 1304 m Mllzm' 1:m~15(n\||lz
e,,,\JJr/,
VX-5
Operating Manual
Channel Steps J/lO/1113/15/20/25/50/100 kHz
Frequency Stability: toil ppm (40°C to +GO°C)
Repeater Shift (default): 1600 kHz (144 MHZ)
tl.6/5.0/7,6 MHZ (430 MHZ)
Emission Type: F2, F3
Antenna Impedance: 50 9
Supply Voltage: Nominal: 742 V DC, Negative Ground
Operating: 1016 V DC, Negative Ground (EXT DC jack)
Current Consumption: 150 mA (Receive)
55 mA (Standby, Saver Off)
16 mA (Standby, Saver On)
400 nA (Auto Power Off)
1,6A (5 W Tx, 50 MHZ)
1,7 A (5 W Tx, 144 MHZ)
1.9 A (4.5 W Tx, 430 MHZ)
Operating Temperature: —20°C to +60°C
Case Size: 58 (W) x 88 (H) x 27 (D) mm (w/o knob & antenna)
Wetght: 77? g
RF Power Output: 5 \V (a, 3 8 V EXT DC IN)
(“V (@ 7 0 RUIZ/144 lViHZ)
445W (@ 7.2 V 430 MHZ)
h'iodulation “we: Variable Reactance
Maximum Deviation: $5 kHZ
Spurious Emission: At least 60 dB below
Microphone Impedance: 2 ks!
ficeiver
Circuit Type: Double-Conversion Superheterodyne
Intermediate Frequencies: lst: 17.25 MHZ (NvFM)
45.8 MHZ (W-FM)
2nd: Mt) kHz (NFM)
10.7 MHZ (W-FM)
"i “V for 10 dB S/N (l ' " MHZ. l\l\l)
(LS) ii\' for 12 dB SlNAD (76~_ \\'»Fl\i)
(J Iti “Y for I'.‘. dB SiNAi) (; 431 AiiiZ/i i 1-148 Din/iiio- 150 DIHZ. N~Fi\i)
Selectivity (—6(lB/—U(Jdl§). lv') kHz/255 kHz (ii-FM)
.\|“ Output“ 10“ m\V u“ 352 for 10 ‘l’u Ti”) (H 7.2 V DC)
Sensitivity:
hfiwi/it‘uuiins nn' sub/er! m L'lmngu H'II/Ilm/ nor/(w. undurv gum'flurm-r/ wit/1177 zmmrcur
16
bands anjy
Accessories
FNBfSSLI
NC-728/C/U
Belt Clip
Hand Strap
Antenna
ACCESSORIES & OPTIONS
Battery Pack
AC Power Supply
Operating Manual
Warranty Card
Options
FNB-SBLI
NC-7ZB/C/U
CD-15
FHA-23
SU-1
MH-34BAB
MH-37AAE
VC-25
E-DC-SB
E»DC-6
CSC-73
CN-B
CT-44
Battery Pack
AC Power Supply
Rapid Charger
Battery Case for 2 x LR-6 type Cell
Barometer Sensor Unrt
Speaker/Microphone
Earpicce/Micrnphone
VOX Headset
Cigarette Lighter DC Power Cable
External Power (“able
Soft Case
BNC to SMAAdapter
Microphone Adapter
17
VX75
Operating Manual
CAUTION 1
Changes or modificahons ta Ihis device rial expressiy approved by
Vassu Musen could vaid Ihe usefs authorizatlon to operate this device.
|. Changes or modificaiions io inis device nei expressiy approved by Vaesu
Musen couiu void me user's auiherizaiinn io operaie irris aeyiee.
2. This device complies Wilh pan 15 oi ine FCC rules. Operation is subjeci in
me foHowing two candillcflsi (ii ihis device may nol cause haimmi
inierierenee, and (2) inis deyrce musi accepr any inierierence including
inierierence mat may cause undesired operation,
3. The scanning receiver in Mrs equipmeni is incapable of iuning, or readily
Daing aiiered. by me User (0 operaie Within ihe frequency bands allocated
(a me Domesiic pubirc Cellular Teiecdrnrnunicairons Service in ins Pari
22s
This eeyice cumphes with RSSVZID 0! Industry Canada Operaiion is suaieci
(O the VoHuwmg [WD commons U] (N5 device may not EauSE inteflerence.
and (2) inrs device musi accept any inieriererice. including inierierence inai
may cause undeswabie Operation 01 this dewce.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2001:04:26 18:55:27
Producer                        : Acrobat Distiller 4.0 for Windows
Author                          : VicodinES /CB /TNN
Title                           : 82100.pdf
Modify Date                     : 2001:04:26 18:55:36-04:00
Page Count                      : 18
EXIF Metadata provided by EXIF.tools
FCC ID Filing: K66VX-5R

Navigation menu