York Affinity Tchd Air Conditioner Owner S 813196 UUM D 0613 User Manual
Affinity-Yzf-Heat-Pump-Owner-S york-affinity-yzf-heat-pump-owner-s-manual
Affinity-Yzh-Heat-Pump-Owner-S york-affinity-yzh-heat-pump-owner-s-manual
Latitude-Tcgd-Air-Conditioner-Owner-S york-latitude-tcgd-air-conditioner-owner-s-manual
Latitude-Tcgf-Air-Conditioner-Owner-S york-latitude-tcgf-air-conditioner-owner-s-manual
Latitude-Thgd-Heat-Pump-Owner-S york-latitude-thgd-heat-pump-owner-s-manual
2014-07-06
User Manual: York Affinity-Tchd-Air-Conditioner-Owner-S
Open the PDF directly: View PDF .
Page Count: 6
Johnson Controls Unitary Products 813196-UUM-D-0613
USER’S INFORMATION MANUAL
OUTDOOR SPLIT-SYSTEM
AIR CONDITIONING OR HEAT PUMP
MODELS: SINGLE PHASE & THREE PHASE
®
TABLE OF CONTENTS
CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
HOW YOUR SYSTEM WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
COOLING CYCLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
HEATING CYCLE (HEAT PUMPS) . . . . . . . . . . . . . . . . . . . . . . . . . 1
System Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SETTING THE THERMOSTAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
THERMOSTATS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
YOUR KEY TO COMFORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
COOLING ONLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
COOLING AND HEATING (HEAT PUMP) . . . . . . . . . . . . . . . . . . . 2
MANUAL CHANGE-OVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
PROGRAMMABLE ELECTRONIC THERMOSTATS . . . . . . . . . . . . . 2
FAN OPERATION SELECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
AUTO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
POWER FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
SYSTEM OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
MANUAL CHANGE-OVER THERMOSTAT . . . . . . . . . . . . . . . . . .2
ELECTRONIC THERMOSTAT . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
TO MAXIMIZE OPERATING EFFICIENCY . . . . . . . . . . . . . . . . . . . . .3
HEATING CONSERVATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
COOLING CONSERVATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
CARE OF SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
COIL CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
SERVICE CALLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
FILTER CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
PARTS INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
EXTENDED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
SOME EFFICIENCY DO’S & DON’TS . . . . . . . . . . . . . . . . . . . . . . .3
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
CONTACT INFORMATION
• Go to website at www.york.com, then click on “Contact Us” and
follow the instructions.
• Contact us by mail:
Johnson Controls Unitary Products
Consumer Relations
5005 York Drive
Norman, OK 73069
The manufacturer recommends that the user read this
manual and keep the manual for future reference.
SAFETY
HOW YOUR SYSTEM WORKS
COOLING CYCLE
If your hand is wet and you blow on it, it feels cool because some of the
moisture is evaporating and becoming a vapor. This process requires
heat. The heat is being taken from your hand, so your hand feels cool.
That’s what happens with an air conditioner. During the cooling cycle,
your system will remove heat and humidity from your home and will
transfer this heat to the outdoor air.
HEATING CYCLE (HEAT PUMPS)
During the heating cycle, your system will remove heat and humidity
from the outdoor air and will transfer this heat to your home. This is pos-
sible because even 0°F outdoor air contains a great deal of heat.
Remember that your heat pump doesn’t generate much heat, it merely
transfers it from one place to another.
System Operation
Your thermostat puts full control of the comfort level in your home at
your fingertips. DO NOT switch your thermostat rapidly ON and OFF or
between HEAT to COOL. This could damage your equipment. Always
allow at least 5 minutes between changes.
SETTING THE THERMOSTAT
THERMOSTATS
YOUR KEY TO COMFORT
Although thermostats may vary widely in appearance, they are all
designed to perform the same basic function: to control the operation of
your air conditioning or heat pump system. Regardless of size or shape,
each thermostat will feature a temperature indicator; a dial, arm, or
push button for selection of the desired temperature; a fan switch to
choose the indoor fan operation; and a comfort switch for you to select
the system mode of operation.
Only approved thermostats have been tested and are fully compatible
with this equipment. Please be aware that many different thermostats
operate on batteries or “power stealing” principals. These types of ther-
mostats can not be supported as trouble free when used with this product.
If your system has been designed to allow both cooling and heating
operation, you may have either a manual change-over type, or a pro-
grammable electronic type thermostat.
Manual change-over simply means that the comfort switch must be
manually positioned every time you wish to switch from the cooling to
heating or heating to cooling modes of operation.
This product must be installed and serviced by a qualified installer or
service agency. Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage.
The main power to the system must be kept ON at all times to prevent
damage to the outdoor unit compressor. If necessary, the thermostat
control switch should be used to turn the system OFF. Should the
main power be disconnected or interrupted for 8 hours or longer, DO
NOT attempt to start the system for 8 hours after the power has been
restored to the outdoor unit. If heat is needed during this 8 hour
period, use emergency heat.
813196-UUM-D-0613
2Johnson Controls Unitary Products
A complete operating instruction is provided by the manufacturer for
each thermostat. Familiarize yourself with its proper operation to obtain
the maximum comfort with minimum energy consumption.
The computerized electronic thermostat is actually a sophisticated elec-
tronic version of a manual change-over type. This thermostat includes
features which allow “set-back” temperature variations for periods of
sleep, or while you are away during the day, and means energy savings
for you. The thermostat also features a digital clock.
COOLING ONLY
If your air conditioning system is designed to provide cooling only (AC),
with no capability for heating operation (heat pump), a two-stage cool-
ing only thermostat, with a manual, one-position “Cool” and “Off” com-
fort switch is all that is required for system operation.
COOLING AND HEATING (HEAT PUMP)
If your system has been designed to allow both cooling and heating
operation, you may have either a manual change-over type, or a pro-
grammable electronic type thermostat with 2-stages of cooling and 2-
stages of heat.
MANUAL CHANGE-OVER
Manual change-over simply means that the comfort switch must be
manually positioned every time you wish to switch from the cooling to
heating or heating to cooling modes of operation.
PROGRAMMABLE ELECTRONIC
THERMOSTATS
The computerized electronic thermostat is actually a sophisticated elec-
tronic version of a manual change-over type. This thermostat includes
features which allow “set-back” temperature variations for periods of
sleep, or while you are away during the day, and means energy savings
for you. The thermostat also features a digital clock.
FAN OPERATION SELECTION
A multi-position fan switch allows you to choose the type of fan opera-
tion of the indoor fan.
AUTO
With the thermostat fan switch set to “AUTO”, the fan will run intermit-
tently as required for either heating or cooling. This position will provide
the lowest operating cost. If you purchased one of our thermostats, they
have an Intelligent fan mode which continually circulates the air during
occupied modes or when you are at home, and can cycle the fan during
unoccupied mode or during the night while you sleep to further con-
serve energy.
ON
CONTINUOUS FAN OPERATION: With the thermostat fan switch set to
“ON”, the indoor fan will not shut off. However, the cooling (AC) or heat-
ing (heat pump) systems will still operate as required by room tempera-
tures. This provides continuous air filtering and more even temperature
distribution to all conditioned spaces.
FAN ONLY OPERATION: On moderate days, usually during spring and
fall, when neither heating nor cooling is required, you may want to run
only the fan to ventilate, circulate and filter the air in your home or build-
ing. Set the comfort control switch to “OFF” and the fan switch to “ON”.
Be sure to return the switches to their original positions for normal oper-
ation.
START-UP
The maximum and minimum conditions for operation must be observed
to assure a system that will give maximum performance with minimum
service.
The comfort control switch is assumed to be in the “OFF” position. If the
main power supply to the outdoor and indoor units is off, turn the appro-
priate disconnects to the “ON” position. Place the system into operation
as follows.
1. Set temperature adjustment to the desired temperature on your
thermostat.
COOLING - The higher the setting, the lower the amount of energy con-
sumed. Federal Guidelines recommend a setting of 78 °F.
HEATING - The lower the setting, the lower the amount of energy con-
sumed. Federal guidelines recommend a setting of 65 °F or lower.
2. After considering “Fan Operation Selection” above, select and set
the fan operation mode you desire.
3. Move the comfort control switch to the desired mode of operation
(Cooling or Heating) found on your particular thermostat.
POWER FAILURE
When accidents, wind storms, etc. disrupt electrical power supply to
your house, switch thermostat to “OFF” position.
SYSTEM OPERATION
MANUAL CHANGE-OVER THERMOSTAT
COOLING YOUR HOME: With the comfort control switch in the
“COOL” position, the system will operate as follows: When the indoor
temperature rises above the level indicated by the temperature adjust-
ment setting, the system will start. The outdoor unit will operate and the
indoor fan will circulate the cooled, filtered air. When the room tempera-
ture is lowered to the setting selected, the system will shut off.
HEATING YOUR HOME: If your system includes a heating unit and the
comfort control switch is in the “HEAT” position, the system will operate
as follows: When the indoor temperature drops below the level indi-
cated by the temperature adjustment setting, the system will start. The
heating system will operate and the indoor fan will circulate the filtered
air. When the room temperature rises to the setting selected, the sys-
tem will shut off. Whether heating or cooling, the fan will continue to
operate if the fan switch was set in the “ON or Intelligent” position. The
“AUTO” setting on the fan switch will allow the fan to shut off when your
system does.
ELECTRONIC THERMOSTAT
The computerized electronic thermostat, when programmed, will func-
tion automatically to operate the system as follows: When the indoor
temperature rises above the higher (COOL) setting, the outdoor unit will
operate and the indoor fan will circulate the cooled, filtered air. When
the room temperature is lowered to the selected level, the system will
shut off. The indoor fan will either shut off or run continuously, depend-
ing upon your choice of fan switch setting. When the indoor tempera-
ture drops below the lower (HEAT) setting, the heating system will
operate, and the indoor fan will circulate the heated, filtered air. When
TABLE 1:
Application Limitations
Air Temperature at
Outdoor Coil, °F Air Temperature at
Indoor Coil, °F
Min. Max. Min. Max.
DB
Cool
DB
Heat
DB
Cool
DB
Heat
WB
Cool
DB
Heat
WB
Cool
DB
Heat
60 -10 115 75 57 501
1. Operation below this temperature is permissible for a short period of
time, during morning warm-up.
72 80
If your cooling and heating temperature adjustments are separate, be
sure to set both.
NOTICE
813196-UUM-D-0613
Johnson Controls Unitary Products 3
the indoor temperature rises to the selected setting, the system will shut
off. The indoor fan will either shut off or run continuously, depending
upon your choice of fan switch setting.
TO MAXIMIZE OPERATING EFFICIENCY
HEATING CONSERVATION
For the most efficient operation, keep storm windows and doors closed
all year long. They not only help insulate against heat and cold, but they
also keep out dirt, pollen, and noise.
Closing drapes at night, keeping fireplace dampers closed when not in
use, and running exhaust fans only when necessary will help you to
retain the air you have already paid to heat.
Keep lamps, televisions, or other heat producing sources away from the
thermostat. The thermostat will sense this extra heat and will not be
able to maintain the inside temperature to the desired comfort level.
COOLING CONSERVATION
To comfortably cool your home, your air conditioner must remove both
heat and humidity. Don’t turn your system off even though you will be
away all day. On a hot day, your system may have to operate between 8
to 12 hours to reduce the temperature in your home to a normal comfort
level.
Keep windows closed after sundown. While the outdoor temperature at
night may be lower than indoors, the air is generally loaded with mois-
ture which is soaked up by furniture, carpets, and fabrics. This moisture
must be removed when you restart your system.
The hotter the outside temperature, the greater the load on your sys-
tem. Therefore do not be alarmed when your system continues to run
after the sun has set on a hot day. Heat is stored in your outside walls
during the day and will continue to flow into your home for several hours
after sunset.
Use your kitchen exhaust fan when cooking. One surface burner on
“HIGH” requires one ton of cooling. Turn on your bathroom exhaust fan
while showering to remove humidity. However, exhaust fans should not
be run excessively. It would decrease efficiency by removing condi-
tioned air.
You can also help your system in the summer by closing drapes or
blinds and by lowering awnings on windows that get direct sunlight.
CARE OF SYSTEM
It is strongly recommended that regular periodic preventative mainte-
nance be performed on this equipment. The person most familiar with
the equipment in your H.V.A.C. system is a dealer. The dealer can
ensure your maintenance program meets the conditions of the War-
ranty”, maximize the efficiency of the equipment, and service your unit
within the federally mandated guidelines with regard to unlawful dis-
charge of refrigerants into the atmosphere.
COIL CARE
Keep the outdoor unit free of foliage, grass clippings, leaves, paper, and
any other material which could restrict the proper air flow in and out of
the unit. The coil may be vacuumed to remove any debris from between
the fins. If the coil becomes excessively dirty, turn the main disconnect
switch to “Off” and wash the coil with your garden hose. Avoid getting
water into the fan motor and control box. Flush dirt from base pan after
cleaning the coil.
SERVICE CALLS
There are a few instances where the user can avoid unnecessary ser-
vice calls. If unit stops functioning properly check the following items
before calling your servicing dealer:
1. Indoor section for dirty filter.
2. Outdoor section for leaf or debris blockage. Eliminate problem, turn
off the thermostat for 10 seconds and attempt start. Wait 5 minutes.
If system does not start, call your servicing dealer.
FILTER CARE
Inspect the air filter(s) at least once a month. If they are dirty, wash
reusable filters with a mild detergent per manufacturer’s recommenda-
tions. Replace disposable filters with new filters. Install the clean filters
with “air flow” arrow in the same direction as the air flow in your duct.
Filters should be clean to assure maximum efficiency and adequate air
circulation.
CLEARANCES
The minimum clearances shown below must be maintained should any
patio or yard improvements be done around the outdoor unit.
• 10" Clearance Coil Area
• 60" Overhead Clearance
• 18" to 24” is the minimum service panel access depending on
model. Refer to the installation manual for details.
• 24" Unit to Unit Distance
PARTS INFORMATION
Replacement parts are available from local contractor/dealer.
EXTENDED WARRANTY
Special warranty packages (called York Care Performance Promise)
are available through your contractor. These packages reduce the
potential cost of service calls following the first year of operation on your
cooling (or heating/cooling) system.
SOME EFFICIENCY DO’S & DON’TS
DON’T heat or cool unused household area. Reduce supply and return
air flow to a minimum in areas which are not living spaces (storage
rooms, garages, basements, etc).
DON’T be a “thermostat jiggler”. Moving your thermostat setting will not
make your system heat or cool any faster. Adjust your thermostat to a
comfortable setting and leave it there.
DON’T restrict air circulation. Placing furniture, rugs, etc. in such a way
that they interfere with air vents will make your system work harder to
achieve a comfortable temperature level. This requires more energy,
which means greater cost to you.
DON’T locate lamps or other heat-producing appliances (radios, TV’s,
heaters, etc.) near your thermostat. The heat from these items will give
your thermostat “false information” about the temperature in the room.
DO select a comfortable thermostat setting, but keep in mind that mod-
eration in temperature selection will save energy.
DO turn on your kitchen exhaust fan when cooking and your bathroom
exhaust fan when showering. Also, make sure your clothes dryer is
properly vented. If these items are neglected, an excess heat and
humidity condition may be created, causing your air conditioning sys-
tem to run longer.
DO set your thermostat a few degrees lower than normal several hours
before entertaining a large group of people in a relatively small area.
People give off a considerable amount of heat and moisture in a closed
area.
DO keep drapes and venetian blinds closed when practical. These
items provide insulation against heat loss/gain.
DO contact a qualified service person to make repairs or adjustments to
your system. He has been trained to perform this service.
Your system contains environmentally friendly refrigerant R-410A,
which operates at high pressures. You may be in danger if you try to
make an attempt to repair your unit. Please contact your local dealer.
813196-UUM-D-0613
4Johnson Controls Unitary Products
NOTES
813196-UUM-D-0613
Johnson Controls Unitary Products 5
Limited Warranty
Residential Split Air Conditioning & Heat Pump Condensing Units
WARRANTY TERMS: Johnson Controls Unitary Products (hereinafter “Company”) warrants this product to be free from defects in factory workman-
ship and material under normal use and service and will, at its option, repair or replace any parts, without charge, subject to the exclusions below,
that prove to have such defects according to the terms outlined in this warranty. Company reserves the right, at its sole discretion, to provide a
replacement unit in the place of repair parts, in which case the warranty period for the replacement unit is limited to the remainder of the original war-
ranty period. Alternatively, Company may, at its option, extend a replacement allowance to be applied toward the purchase of a new unit marketed by
Company. The exact amount of the allowance will be determined at the discretion of Company, based upon current market conditions, but in no case
shall this allowance exceed thirty (30) percent of the original consumer purchase price of the unit excluding such items as ductwork, wiring, piping,
and installation costs. The warranty period for repair or replacement parts or unit provided hereunder shall not extend beyond the warranty period
stated below. Company shall have no responsibility hereunder for installation, shipping, handling, or other charges except as specifically provided
herein.
This warranty covers only the equipment described by the Product Model Number and Unit Serial Number on the equipment or listed on the War-
ranty Registration Card, and applies only to products installed in the United States, Canada, or Puerto Rico. Tampering, altering, defacing, or remov-
ing the product serial number will serve to void this warranty. This warranty extends only to the original consumer purchaser and is nontransferable.
For this warranty to apply, the product must be installed according to Company recommendations and specifications, and in accordance with all
local, state, and national codes; and the product or residence must not be removed from its place of original installation. This warranty does not apply
to any unit sold over the Internet, by telephone or other electronic means unless the dealer that buys or sells a unit over the Internet, by telephone or
other electronic means also installs the unit. In the absence of a recorded Warranty Registration Card, the warranty period will begin upon product
shipment from Company. If you are unaware of the date the warranty became effective, contact Company at (877) 874-7378 or visit www.upgproduc-
tregistration.com.
FOR PRODUCT REGISTRATION: For your benefit and protection, register your product with Company promptly after installation. This will initiate
the warranty period and allow us to contact you, should it become necessary. You can register your product online at www.upgproductregistra-
tion.com or by returning the Warranty Registration Card on the back page of this packet.
FOR WARRANTY SERVICE OR REPAIR: Notify your Installing Dealer or a Participating Dealer, preferably in writing, as soon as possible after dis-
covery of the problem. Be sure to include the Product Model Number, Unit Serial Number, Installation Date, and a description of the problem. You
may find the Installing Dealer's name on this page or on the equipment, and you can locate Participating Dealers online at www.yorkupg.com.
If a Dealer response is not received within a reasonable amount of time, notify Company at: Johnson Controls Unitary Products, Consumer Rela-
tions, 5005 York Drive, Norman, OK 73069 or by telephone at (877) 874-7378. All warranty service or repair will be performed during regular busi-
ness hours, Monday through Friday 9:00 AM - 5:00 PM. Service requests sent to Company without prior Dealer contact will be referred back to a
Participating Dealer. Because this process takes time, it is in the best interest of the Consumer to contact a Participating Dealer directly.
WARRANTY PERIOD: The warranty period in years, depending on the part, is as shown in the chart below.
NOTES:
*All 3 phase models (with 43/44 voltage codes) have 5-year compressor and 1-year parts warranty and are not eligible for 10-year parts warranty.
To qualify for the # E-Coat Coil or factory approved equivalent (contact the factory for details) Coil warranty, the † Extended 10-year parts warranty, the †† Extended 10-
year compressor warranty, and/or the ‡ Lifetime compressor warranty, the unit must be registered online at www.upgproductregistration.com within 90 days of installa-
tion for replacement units or within 90 days of closing for new home construction. In some states, registration is not required, but proof of installation is required.
The # E-Coat Coil warranty only covers condenser coil failures due to corrosion, and provides the homeowner with the option of replacement of either (a) the condenser
coil, or (b) the condensing unit, at the discretion of the Participating Dealer.
Guardian Brand products have a 5-year compressor and 5-year parts warranty and are not eligible for the 10-year parts warranty.
MAINTENANCE: Company strongly recommends regular periodic preventive maintenance on this equipment. The person most familiar with the
equipment in your HVAC system is a Participating Dealer. The Participating Dealer can ensure that your maintenance program meets the “Company
Warranty” conditions, maximize the equipment efficiency, and service your unit within the mandated guidelines with regard to unlawful discharge of
refrigerants into the atmosphere.
Product Model Number: ____________________________________
Unit Serial Number: _______________________________________
Installation Date: __________________________________________
Installing Dealer: __________________________________________
CONDENSING UNITS
CONDENSING UNITS COMPRESSOR PARTS E-COAT COIL
R-410A Models: GCGD, GHGD R-22 Dry Ship Models: GCGD, GHGD 5 5 5 #
R-410A Models: T(C,H)GD, RAC13J, & RHP13(J,R) 5 or 10†† 5 or 10†5 #
R-410A Models: T(C,H)JD*, Y(C,H)JD*, (Y,T)HJR, T(C,H)GF, T(C,H)JF,
Y(C,H)JF, TCHD*, RAC14J, RHP14J 10 5 or 10†5 # (Except TCHD models
which are NA)
R-410A Models: (C,Y)ZF (C,Y)ZH, AC(6,8)B, AL(6,8)B, HC(6,8)B, HL(6,8)B 10 or Lifetime‡5 or 10†NA
Subject to change without notice. Published in U.S.A. 813196-UUM-D-0613
Copyright © 2013 by Johnson Controls, Inc. All rights reserved. Supersedes: 813196-UUM-C-0412
York International Corp.
5005 York Drive
Norman, OK 73069
EXCLUSIONS: This warranty does not cover any:
1. Shipping, labor, or material charges or damages resulting from transportation, installation, or servicing.
2. Damage or repairs required as a consequence of mishandling, faulty installation, misapplication, abuse, improper servicing, unauthorized altera-
tion, or improper operation.
3. Damages or failure to start resulting from improper voltage conditions, blown fuses, open circuit breakers, or other inadequacy or interruption of
electrical service or fuel supply.
4. Fuses, either internal or external to the product.
5. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing, or handling of either defective parts or replace-
ment parts.
6. Products removed from their original location for reinstallation purposes.
7. Damages resulting from accident, abuse, fire, flood, alteration, or acts of God.
8. Damages resulting from use of the product in a corrosive atmosphere.
9. Normal maintenance, or damages resulting from failure to perform normal maintenance, as outlined in the installation and servicing instructions
or owner's manual.
10. Cleaning or replacement of filters, nozzles, or orifices.
11. Damages resulting from operation with inadequate supply of air or water; Damages resulting from failure to properly and regularly clean air and/
or water side of condenser and evaporator.
12. Damages resulting from: (I) freezing of condenser water or condensate; (II) inadequate or interrupted water supply; (III) use of corrosive water;
(IV) fouling or restriction of the water circuit by foreign material or like causes.
13. Damages caused by improper parts, components or accessories not suitable for use in or with the unit. For a list of parts that are known to be
compatible please reference the equipment renewal parts list, contact a Participating Dealer for assistance, or call 1-877-874-7378.
14. Electricity or fuel costs, or increases in fuel or electric costs, for any reason including additional or unusual use of supplemental electric heat.
This warranty is in lieu of all other express warranties. All implied warranties, including the implied warranty of merchantability and fitness for a partic-
ular purpose are limited in duration to the actual warranty period applicable to the part. Some states do not allow the disclaimer of implied warranties,
so the above disclaimer may not apply to you. In addition, some states do not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to you. In no event, whether as a result of breach of warranty or contract, tort (including negligence), strict liability, or other-
wise, shall Company be liable for special, incidental, or consequential damages or expenses, including but not limited to loss of use of the equipment
or associated equipment, lost revenues or profits, cost of substitute equipment, or cost of fuel or electricity.
The above limitations shall inure to the benefit of Company's suppliers and subcontractors. The above limitation on consequential damages shall not
apply to injuries to persons in the case of consumer goods. Company does not assume, or authorize any other person to assume for Company, any
other liability for the sale of this product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state.