York Heat Recovery Ventilator Sell Sheet
2015-09-09
: York Heat-Recovery-Ventilator-Sell-Sheet york-heat-recovery-ventilator-sell-sheet-811899 york pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
S1-ERV160 & S1-ERV220 German Engineered motors All Source1 Heat Recovery Ventilators are designed with high-performance and reliable motors for your comfort and peace of mind. Factory sealed and dynamically balanced, our motors are maintenance-free for years to come. ISF™ collar system Quick and simple to install thanks to our revolutionary “Insert Slide and Fix™” collar system. The ISF™ 6” (dia.) collar system enables you to manipulate duct within your reach and then insert the collar to the HRV by sliding it in place, for a better and quicker installation. SPM™ attachment system The entire line of Source1 HRV/ERV products is designed for installation by a single person. “Single Person Mounting™” will enable you to save time and effort by offering you a variable attachment system and maximizing your basement space. DuoTrol™ balancing system Silent and economical…By reducing motor speed to balance the unit, you avoid the noise that would be produced by balancing dampers. In addition, with this technology the unit will consume less energy. www.source1parts.com Features • 2 operating modes (Intermittent and Continuous Ventilation) • Variable speed • Proportional defrost (Patent Pending) • ISF™ 6” (dia.) collar system • 5-year limited warranty on ventilation motors • 5-year limited warranty on the enthalpy recovery core • 5-year limited warranty on all other components Energy Recovery Core operation system The illustrations show the operation of a Source1 ERV system. Outside air is pushed through the heat exchanger, which acts as a noise attenuator. This process is very silent and provides you with better home comfort. The recirculation mode takes already-heated ambient air from a selected area, recirculates it through the unit’s filters, and distributes throughout your home. This option enables the unit to have an auxiliary air supply during the system’s defrost period in winter and offers you better air quality without unpleasant odors. PUBL-5868-0107 S1-ERV.indd 1 7/28/10 11:09:40 AM Easy Access Why is our system the best? Removable top hinge door Features Benefits • Selection of controls • Selection of filters and accessories • Compact installation • DuoTrol™ balancing system (patent pending) • Sloped drain pan • “Push Through” design • Backward inclined motor blades • Permanent lubrication of PSC motors • Door opens upward • No obstruction around the drain pan • Simple electronic control • Auxiliary connecting relays • 5-year limited warranty on the ventilation motors • Lifetime warranty on the heat recovery core • Easy access to the control connection box • ISF™ 6” (dia.) collar system (patent pending) • SPM attachment system • Operating flexibility • Better air quality • Maximizes your space • Silent and economical • Eliminates bacteria-producing stagnant water • Better performance • Maintenance-free bearings • Easy access • Easy to clean • Easy to operate • No relay necessary • Reliable and trouble-free • Peace of mind • Eliminates risks of error • Quick and simple to install • Variable settings 21-1/2" 23-7/8" S1-HRV160: 11-3/8" S1-HRV220: 16-1/2" External Static Pressure Pa in. W.C. 25 0.1 50 0.2 75 0.3 100 0.4 125 0.5 150 0.6 175 0.7 Net Supply Air Flow L/s CFM 82 174 77 163 73 154 67 142 61 130 57 122 52 110 L/s 83 77 73 67 62 58 52 Gross Air Flow Supply Exhaust CFM L/s CFM 175 109 231 164 98 207 154 88 187 143 77 163 131 68 144 122 60 128 111 56 118 Pressure Pressure -- Pascal Pascal 250 250 Pascals Pascals == 1” 1”of of Water Water Ventilation Performance S1-ERV160 175 150 125 100 75 50 25 0 Proportional Defrost operation system 20 40 60 80 100 120 Gross Airflow - L/s External Static Pressure Pa in. W.C. 25 0.1 50 0.2 75 0.3 100 0.4 125 0.5 150 0.6 175 0.7 Net Supply Air Flow L/s CFM 97 206 92 195 87 184 83 176 75 159 69 146 64 136 L/s 98 93 88 83 75 69 64 Gross Air Flow Supply Exhaust CFM L/s CFM 208 115 244 197 103 218 186 98 208 176 90 191 159 82 174 146 74 157 136 64 136 Pressure Pressure -- Pascal Pascal 250 250 Pascals Pascals == 1” 1”of of Water Water Ventilation Performance S1-ERV220 175 150 125 100 75 50 25 0 Sloped Drain Pan 20 40 60 80 100 120 Gross Airflow - L/s Energy Performance S1-ERV160 Supply Temperature ˚C ˚F 0 32 0 32 0 32 -25 -13 Energy Performance S1-ERV220 Net Average Sensible Apparent Air Flow Power Recovery Sensible L/s CFM Watts Efficiency Effectiveness 31 66 88 66 78 42 89 104 64 76 56 119 114 63 72 32 67 86 59 77 Supply Temperature ˚C ˚F 0 32 0 32 0 32 -25 -13 Net Average Sensible Apparent Air Flow Power Recovery Sensible L/s CFM Watts Efficiency Effectiveness 56 119 124 63 74 75 159 158 60 68 86 182 172 59 66 52 110 147 59 75 Specifications S1-ERV160 S1-ERV220 Important Information Size Heat exchanger (L x H x W) CFM Type of heat exchanger Exchange surface Voltage Amperage Defrost type Certification 23-7/8” x 21-1/2” x 11-3/8” 12” x 12” x 10” 30 to 160 cross-flow (Polypropylene) 104 ft2 120 VAC @ 60 Hz 1.5 A Evacuation HVI, CCSAUS 23-7/8” x 21-1/2” x 16-1/2” 12” x 12” x 15” 50 to 220 cross-flow (Polypropylene) 150 ft2 120 VAC @ 60 Hz 1.5 A Evacuation HVI, CCSAUS • All Source1 products are backed by the best limited warranty on the market. 900EHD 0606 EGD S1-ERV.indd 2 The defrost energy in controlled by the outdoor air temperature. The motor speed essentially increases as outdoor temperature drops to provide increased defrost capacity. For instance, at 23˚F the defrost mode will function at low speed. This technology reduces energy usage by eliminating unnecessary defrost energy during milder days and offers a more silent operation. • Source1 reserves the right to modify a product, without prior notice, whether in design, color or specifications, in order to offer at all times a quality product that is highly competitive. • Please consult local authorities to find out whether the installation of electrical products requires the services of a certified technician or electrician. drainage system Source1 HRV/ERV units are equipped with an easy-access sloped drain pan, so that excess condensation that might accumulate inside the unit goes to the center of the drain pan to be evacuated. Ventilator Accessories The entire range of Source1 controls is offered with features making your ventilations system simple, easy to operate and backed by a 5-year limited warranty. S1-DEHUSTAT Control PUBL-5868-0107 • Dehumidistat to select the humidity level. 7/28/10 11:09:50 AM
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Create Date : 2010:07:28 11:09:31-04:00 Metadata Date : 2014:12:05 08:57:11-06:00 Modify Date : 2014:12:05 08:57:11-06:00 Creator Tool : Adobe InDesign CS3 (5.0) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 16814 bytes, use -b option to extract) Instance ID : uuid:feb1cea9-3b0e-47d9-b681-42a9f5c43e6b Document ID : adobe:docid:indd:b8e22ad0-74ba-11db-97fe-d465f1b20ee7 Rendition Class : proof:pdf Derived From Instance ID : b8e22acf-74ba-11db-97fe-d465f1b20ee7 Derived From Document ID : adobe:docid:indd:05147990-74a9-11db-97fe-d465f1b20ee7 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 300.00, 240.00, 240.00, 300.00, 240.00, 300.00, 72.00, 72.00, 300.00, 300.00, 300.00 Manifest Placed Y Resolution : 300.00, 300.00, 240.00, 240.00, 300.00, 240.00, 300.00, 72.00, 72.00, 300.00, 300.00, 300.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:FAD912F374B611DBB8F58C2FB84A23DB, uuid:F5B03538153311DE84D5F99D88ECCE50, uuid:0D5EEB4161BD11DBABF3D5DDD9FA2159, uuid:0D5EEB4161BD11DBABF3D5DDD9FA2159, uuid:8417A08E650C11DBA1FCDDB8FA8347CF, uuid:0D5EEB4861BD11DBABF3D5DDD9FA2159, uuid:6FF64E6C463811DB87979328B71AB38B, uuid:cace097f-6248-11da-ad99-841d310a1efe, uuid:cace097f-6248-11da-ad99-841d310a1efe, uuid:B0E4217D611D11DBA821BD2D15C59F85, uuid:c9bbd05e-79ac-11da-ba07-ec501dd8d55b, uuid:20f126bb-79ac-11da-ba07-ec501dd8d55b Manifest Reference Document ID : uuid:DA9C31BF74B511DBB8F58C2FB84A23DB, uuid:5873A637DBE1DA11A7FBE4969C85634D, uuid:0D5EEB4061BD11DBABF3D5DDD9FA2159, uuid:0D5EEB4061BD11DBABF3D5DDD9FA2159, uuid:337D3D0B61C511DBABF3D5DDD9FA2159, uuid:CF604E1D3E8F11DBA0C8A21E1F66145E, uuid:3D2EA065462C11DB87979328B71AB38B, adobe:docid:photoshop:cace097e-6248-11da-ad99-841d310a1efe, adobe:docid:photoshop:cace097e-6248-11da-ad99-841d310a1efe, uuid:B0E4217C611D11DBA821BD2D15C59F85, adobe:docid:photoshop:c9bbd05d-79ac-11da-ba07-ec501dd8d55b, adobe:docid:photoshop:20f126ba-79ac-11da-ba07-ec501dd8d55b Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Page Layout : OneColumn Page Mode : UseThumbs Page Count : 2 Creator : Adobe InDesign CS3 (5.0)EXIF Metadata provided by EXIF.tools