923178-UTG-B-0114 TECHNICAL GUIDE LX SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 16 SEER – 1 PHASE 3/4 THRU 2 NOMINAL TONS MODELS: DCMF/DHMF Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.upgnet.com Additional rating information can be found at www.ahridirectory.org WARRANTY SUMMARY* Standard 2-Years limited parts warranty. Standard 6-Years limited compressor warranty. DESCRIPTION The Single-Split Series are ductless climate systems. They are designed with a matching indoor unit for optimum performance and efficiency. These climate systems are supported with accessories and documents to serve specific functions. FEATURES Variable Frequency Rotary Compressor - Twin rotary inverter compressor on all models features high efficiency operation that modulates down to 15 Hz and as high as 120 Hz for reduced vibration and quiet operation. Brushless DC motor uses powerful Neodymium magnets that are approximately 15-20 times stronger than ferrite magnets used in conventional AC compressors. The DC Inverter Control provides continuous operation, while adjusting capacity according to room temperature. The accurate sensing of cooling or heating loads prevents frequent changes in capacity and ensures efficient, economical operation. Low Ambient Cooling Operation Down to 5 °F - This feature allows for a space to be air-conditioned even in outdoor temperatures as low as 5 °F. This cooling ability is important when dealing with server equipment rooms, surveillance mechanical rooms, restaurant kitchens, fitness centers, and more. Load Variation Management System - The outdoor coil thermistor continuously monitors the temperature and communicates with the microprocessor. Depending on the temperature measured, the compressor will be allowed to increase the frequency if needed to meet the load or reduce frequency as the load is reduced. High Pressure Discharge Temperature - The compressor discharge line thermistor continuously monitors the temperature and communicates with the microprocessor. Depending on the temperature measured, the compressor will be allowed to increase the frequency to meet the load or is forced to run at the current or reduced frequency. If the temperature gets excessively high, the compressor will be de-energized. Defrost Control (Heat Pump Models) - Defrost cycle is automatically enabled if there is a build-up of frost on the outdoor coil. Outdoor fan and indoor blower operation is terminated during the defrost cycle. H1 is displayed on the indoor unit panel on the front cover during a defrost cycle. Reversing Valve (Heat Pump Models) - 4-way interchange reversing valve effects a rapid change in direction of refrigerant flow resulting in quick changeover from cooling to heating and vice versa. Valve operates on system pressure differential between outdoor unit and indoor unit. R-410A Refrigerant - Unit is pre-charged with R410A refrigerant that uses PVE refrigerant oil. Polyvinyl ether (PVE) is an innovative refrigerant oil specially formulated for hydrofluorocarbon (HFC) refrigeration systems. In addition to providing lubricating properties, it also has a number of other applied advantages that help to increase the reliability of the refrigeration systems where it is applied. Refrigerant Line Connections, Service Valve - Outdoor units are designed with easy service and maintenance in mind. Maintenance points are located behind easy-access panels, to make installation and service a breeze for a trained technician. Flare connection lines are located on side of unit cabinet. Fully serviceable brass service valve prevents corrosion and provide access to refrigerant system. Shut-off valve that can be fully shut off while 2-way suction/vapor valve (with service port) may be front seated to manage refrigerant charge while servicing system. Air Deflection Louvers - Horizontal louvers default to the cooling or heating position when the unit is operating. Horizontal louvers can be set to a preset oscillating range or fixed position from the wireless remote control. Full oscillating is the default setting when button is pushed. Vertical louvers can be manually adjusted to direct the airflow for optimal comfort. Indoor Coil Freeze Protection - The indoor coil thermistor monitors the coil temperature continuously. Any time the coil temperature drops below 30°F, the compressor and the outdoor fan (30 seconds later) will be switched off until the coil temperature rises above 43°F and the compressor has been off for a minimum of 3 minutes. I FEEL Function - When I FEEL is activated, the system will satisfy the cooling or heating temperature setpoint where the remote control is located. When I FEEL is deactivated, the system will satisfy the cooling or heating temperature setpoint where the indoor unit is located. This feature provides homeowners with optimum comfort whether they are near or far from the indoor unit. Hot Heat Pump (cold air prevention) - In heating mode, the indoor fan will be delayed from 1 to 3 minutes to allow refrigerant to warm up and avoid cold blow. This may occur during: • Initial start-up of a heating cycle • Immediately after completion of an Auto mode operation • Heating under extremely low indoor temperatures FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 923178-UTG-B-0114 2 Johnson Controls Unitary Products 923178-UTG-B-0114 SPECIFICATIONS AIR CONDITIONERS DCMF09NWM42Q1 DCMF12NWM42Q1 DCMF18NWM42Q1 DCMF24NWM42Q1 DCMF09CSM42Q1 DCMF12CSM42Q1 DCMF18CSM42Q1 DCMF24CSM42Q1 Function Cooling Cooling Cooling Cooling Rated Voltage 208/230 208/230 208/230 208/230 Model (Indoor/Outdoor) Frequency (Hz) Total Capacity (BTUH) (High/Standard/Low) Total Capacity (W) (High/Standard/Low) 60Hz 60Hz 60Hz 60Hz 11500/9000/3800 12500/12000/3300 21000/18000/4500 24000/22000/6400 7032/6446/1875 3370/2637/1114 3663/3516/967 6155/5276/1319 Rated Power Input (W) 882 1224 1621 2200 Nominal Input Current (A) 4.01 5.56 7.37 10.00 SEER 16.00 16.00 16.00 16.00 Air Flow Volume (CFM) (H/M/L) 330/300/260/210 340/300/260/210 470/400/330/270 590/440/300/200 Air Flow Volume (m3/h) (H/M/L) 560/510/440/370 580/520/440/370 800/680/560/460 1000/750/520/350 Dehumidifying Volume (cu.ft./h) 0.028 0.049 0.064 0.075 Dehumidifying Volume (l/h) 0.80 1.40 1.80 2.13 EER 10.2 9.8 11.1 10 Model of Indoor Unit DCMF09NWM42Q1 DCMF12NWM42Q1 DCMF18NWM42Q1 DCMF24NWM42Q1 Fan Motor Speed (r/min) (SH/H/M/L) 1450/1180/1000/850 1300/1100/900/700 1350/1150/950/750 1400/1150/1000/850 Output of Fan Motor (w) 15 15 20 36 Fan Motor Capacitor (uF) 1.2 1.2 1.5 2.5 Fan Motor RLA (A) 0.19 0.19 0.32 0.45 Cross-flow - 1 Cross-flow - 1 Cross-flow - 1 Cross-flow - 1 Diameter-Length (inch) 3.6 × 23.4 3.6 × 23.4 3.9 × 25.6 3.9 × 30.1 Diameter-Length (mm) 92 × 594 92 × 595 98 × 650 98 × 765 Fan Type-Piece Indoor Unit Evaporator Aluminum Fin-copper Tube Aluminum Fin-copper Tube Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter (inch) Φ 0.276 Φ 0.276 Φ 0.276 Pipe Diameter (mm) φ7 φ7 φ7 φ7 Row-Fin Gap (inch) 2 - 0.055 2 - 0.055 2 - 0.055 2 - 0.059 Row-Fin Gap (mm) 2-1.4 2-1.4 Coil length (L) x height (H) x coil width (W) (inch) 24.0 × 11.6 × 0.9 24.0 x 11.6 × 0.9 Coil length (L) x height (H) x coil width (W) (mm) 2-1.4 25.9 × 12.0 × 1.0 Φ 0.276 2-1.5 30.1 × 13.5 × 1.0 610 × 24 × 294 610 × 24 × 294 657 × 25.4 × 304.8 Output of Swing Motor (W) 1.5 1.5 2 765 × 25.4 × 342.9 3 Fuse (A) 3.15 3.15 3.15 3.15 Sound Pressure Level dB (A)(SH/H/M/L) 43 / 38 / 32 / 26 44 / 39 / 33 / 28 48 / 43 / 38 / 34 49 / 43 / 39 / 34 Sound Power Level dB (A)(SH/H/M/L) 53 / 48 / 42 / 36 54 / 49 / 43 / 38 58 / 53 / 48 / 43 59 / 53 / 49 / 44 Dimension (W/D/H) (inch) 30.3 × 7.9 × 11.1 30.3 × 7.9 × 11.1 34.1 × 8.5 × 12.0 39.7 × 8.7 × 12.4 Dimension (W/D/H) (mm) 770 × 201 × 282 770 × 201 × 282 865 × 216 × 305 1008 × 221 × 315 Dimension of Package (L/W/H) (inch) 33.3 × 10.9 × 13.9 33.3 × 10.9 × 13.9 37.3 × 12.2 × 15.1 42.2 × 12.3 × 15.6 Dimension of Package (L/W/H) (mm) 847 × 276 × 352 847 × 276 × 352 948 × 310 × 383 1073 × 313 × 395 Net Weight /Gross Weight (lbs) 19 / 25 20 / 27 27 / 35 33.0 / 44.0 Net Weight /Gross Weight (kg) 8.6 / 11.5 9.0 / 12 12.0 / 16 15 / 20 Continued on next page. Johnson Controls Unitary Products 3 923178-UTG-B-0114 AIR CONDITIONERS (Continued) Model of Outdoor Unit DCMF09CSM42Q1 DCMF12CSM42Q1 DCMF18CSM42Q1 GREE GREE MITSUBISHI SANYO Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary L.R.A. (A) 16.50 16.50 27 41 Compressor RLA (A) 6.22 6.22 10.86 11.38 1630 Compressor Manufacturer/trademark Compressor Type Compressor Power Input (W) Throttling Method Working Temp Range (oF) Working Temp Range (°C) Condenser 1245 Capillary EXV 5 ~ 115 5 ~ 115 5 ~ 115 5 ~ 115 -15 ~ 46 -15 ~ 46 -15 ~ 46 -15 ~ 46 Aluminum Fin-copper Tube Aluminum Fin-copper Tube Aluminum Fin-copper Tube Aluminum Fin-copper Tube Φ 0.276 Φ 0.276 Φ 0.276 φ7 φ7 φ7 φ7 Rows-Fin Gap (inch) 1 - 0.055 2 - 0.055 2 - 0.055 2 - 0.055 Φ 0.276 1-1.4 2-1.4 2-1.4 2-1.4 Coil length (L) x height (H) x coil width (L) (inch) 25.5 × 20.8 × 0.8 25.5 × 20.8 × 1.5 33.0 × 26.0 × 1.5 33.6 × 26.0 × 1.5 Coil length (L) x height (H) x coil width (L) (mm) 647 × 19.05 × 528 647 × 38.1 × 528 837 × 38.1 × 660 853 × 38.1 × 660 Fan Motor Speed (rpm) 880±20 880±20 690 690 Output of Fan Motor (W) 21 21 60 60 0.25 0.25 0.62 0.62 Fan Motor Capacitor (uF) Fuse (A) Outdoor Unit 950 Capillary Pipe Diameter (mm) Fan Motor RLA (A) 2 2 3 3.5 15A 15A 25A 25A Air Flow Volume of Outdoor Unit (CFM) 944 944 1887 1887 Air Flow Volume of Outdoor Unit (m3/h) 1600 1600 3200 3200 Fan Type-Piece Axial-flow-1 Axial-flow-1 Axial-flow-1 Axial-flow-1 Fan Diameter (inch) 14.6 14.6 20.5 20.5 Fan Diameter (mm) 370 370 520 520 Defrosting Method Automatic Defrosting Automatic Defrosting Automatic Defrosting Automatic Defrosting Climate Type T1 T1 T1 T1 Permissible Excessive Operating Pressure for the Discharge Side (PSI) 624 624 624 624 Permissible Excessive Operating Pressure for the Discharge Side (MPa) 4.3 4.3 4.3 4.3 Permissible Excessive Operating Pressure for the Suction Side (PSI) 363 363 363 363 Permissible Excessive Operating Pressure for the Suction Side (MPa) 2.5 2.5 2.5 2.5 56 Sound Pressure Level dB (A) 49 52 56 Sound Power Level dB (A) 59 62 66 66 Dimension (W/D/H) (mm) 28.0 × 12.5 × 21.7 28.0 × 12.5 × 21.7 37.9 × 15.6 × 27.6 37.9 × 15.6 × 27.6 Dimension (W/D/H) (mm) Connection Pipe 950 Capillary Pipe Diameter (inch) Rows-Fin Gap (mm) 4 DCMF24CSM42Q1 711 × 318 × 551 711 × 318 × 551 963 × 396 × 701 963 × 396 × 701 Dimension of Package (L/W/H) (inch) 30.4 × 13.7 × 23.3 30.4 × 13.7 × 23.3 40.4 × 17.9 × 28.9 40.4 × 17.9 × 28.9 Dimension of Package (L/W/H) (mm) 771 × 348 × 592 771 × 348 × 592 1026 × 455 × 735 1026 × 455 × 735 Net Weight /Gross Weight (lbs) 64 / 73 68 / 77 104 / 115 112 / 123 Net Weight /Gross Weight (kg) 29 / 33 31 / 35 47 / 52 51 / 56 Refrigerant Charge (oz) 26.1 35.3 44.1 54.7 Refrigerant Charge (kg) 0.74 1.00 1.25 1.55 MCA 10.0 10.0 15.0 16.0 MOP 15.0 15.0 25.0 25.0 Length (ft) 25 25 25 25 Length (m) 7.5 7.5 7.5 7.5 Gas additional charge (oz/ft) 0.2 0.2 0.2 0.2 Gas additional charge (g/m) 15 15 15 15 Φ 1/4 Φ 1/4 Φ 1/4 Φ 1/4 Outer Diameter Liquid Pipe (inch) φ6 φ6 φ6 φ6 Outer Diameter Gas Pipe (inch) Φ 3/8 Φ 3/8 Φ 1/2 Φ 1/2 Outer Diameter Gas Pipe (mm) φ9.52 φ9.52 φ12 φ12 32.8 32.8 32.8 32.8 9.9 Outer Diameter Liquid Pipe (mm) Max Height Distance (ft) Max Height Distance (m) 9.9 9.9 9.9 Max Length Distance (ft) 49.2 49.2 82 82 Max Length Distance (m) 14.9 14.9 24.9 24.9 Johnson Controls Unitary Products 923178-UTG-B-0114 HEAT PUMPS Model (Indoor/Outdoor) Function DHMF09NWM42Q1 DHMF12NWM42Q1 DHMF18NWM42Q1 DHMF09CSM42Q1 DHMF12CSM42Q1 DHMF18CSM42Q1 Cooling Rated Voltage Heating Cooling 208/230 Frequency (Hz) 60Hz Heating Cooling Heating DHMF24NWM42Q1 DHMF24CSM42Q1 Cooling Heating 208/230 208/230 208/230 60Hz 60Hz 60Hz Total Capacity (Btu/h) (High/Standard/Low) 11500/9000/ 3800 11500/9000/ 3300 12500/12000/ 3300 12500/12000/ 21000/18000/ 23000/19200/ 24000/22000/ 26600/26600/ 3400 4500 4000 6400 4100 Total Capacity (W) (High/Standard/Low) 3370/2637/ 1114 3370/2637/ 967 3663/3516/ 967 3663/3516/ 996 6155/5276/ 1319 6741/5276/ 1172 7032/6446/ 1875 7796/6446/ 1202 Rated Power Input (W) 882 799 1224 1065 1621 2123 2200 3118 Nominal Input Current (A) 4.01 3.63 5.56 4.84 7.37 9.65 10.00 14.17 16.00 8 16 9.5 SEER/HSPF Air Flow Volume (CFM) (H/M/L) 16.00 8.5 16.00 8.5 330/300/260/210 330 340/300/260/210 341 470/400/330/270 590/440/300/200 580/520/440/370 580 Air Flow Volume (m3/h) (H/M/L) 560/510/440/370 800/680/560/460 1000/750/520/350 Dehumidifying Volume (cu.ft./h) 0.028 0.049 0.064 0.075 Dehumidifying Volume (l/h) 0.80 1.40 1.80 EER / C.O.P Model of Indoor Unit Fan Motor Speed (r/min) (SH/H/M/L) 3.32 DHMF09NWM42Q1 1300/1100/ 900/700 1300/1150/ 980/820 9.8 3.3 DHMF12NWM42Q1 1350/1150/ 950/750 1350/1190/ 1020/850 11.1 2.13 2.65 DHMF18NWM42Q1 1400/1150/ 1000/850 1450/1250/ 1100/950 10 2.5 DHMF24NWM42Q1 1400/1180/ 1000/850 1450/1380/ 1200/1150 Output of Fan Motor (w) 15 15 20 36 Fan Motor Capacitor (uF) 1.2 1.2 1.5 2.5 Fan Motor RLA(A) 0.19 0.19 0.32 0.45 Cross-flow - 1 Cross-flow - 1 Cross-flow - 1 Cross-flow - 1 Diameter-Length (inch) 3.6 × 23.4 3.6 × 23.4 3.9 × 25.6 3.9 × 30.1 Diameter-Length (mm) 92 × 594 92 × 595 98 × 650 98 × 765 Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter (inch) Φ 0.276 Φ 0.276 Φ 0.276 Pipe Diameter (mm) φ7 φ7 φ7 φ7 Row-Fin Gap (inch) 2 - 0.055 2 - 0.055 2 - 0.055 2 - 0.059 Row-Fin Gap (mm) Fan Type-Piece Evaporator Indoor Unit 10.2 Aluminum Fin-copper Tube Aluminum Fin-copper Tube Φ 0.276 2-1.4 2-1.4 2-1.4 2-1.5 Coil length (L) x height (H) x coil width (W) (inch) 24.0 × 11.6 × 0.9 24.0 × 11.6 × 0.9 25.9 × 12.0 × 1.0 30.1 × 13.5 × 1.0 Coil length (L) x height (H) x coil width (W) (mm) 610 × 24 × 294 610 × 24 × 294 657 × 25.4 × 304.8 765 × 25.4 × 342.9 Output of Swing Motor (W) 1.5 1.5 2 3 Fuse (A) 3.15 3.15 3.15 3.15 49 / 43 / 39 / 34 Sound Pressure Level dB (A) (SH/H/M/L) 43 / 38 / 32 / 26 44 / 39 / 33 / 28 48 / 43 / 38 / 34 Sound Power Level dB (A)(SH/H/M/L) 53 / 48 / 42 / 36 54 / 49 / 43 / 38 58 / 53 / 48 / 43 59 / 53 / 49 / 44 30.3 × 7.9 × 11.1 30.3 × 7.9 × 11.1 34.1 × 8.5 × 12.0 39.7 × 8.7 × 12.4 Dimension (W/D/H) (inch) Dimension (W/D/H) (mm) 770 × 201 × 283 770 × 201 × 283 865 × 215 × 305 1008 × 221× 315 Dimension of Package (L/W/H) (inch) 33.3 ×10.9 × 13.9 33.3 × 10.9 × 13.9 37.3 × 12.2 × 15.1 42.2 × 12.3 × 15.6 Dimension of Package (L/W/H) (mm) 847 × 276 × 352 847 × 276 × 352 948 × 310 × 383 1073 × 313 × 395 Net Weight /Gross Weight (lbs) 19 / 25 20 / 27 27 / 35 33.0 / 44.0 Net Weight /Gross Weight (kg) 8.6 / 11.5 9.0 / 12.0 12.0 / 16.0 15 / 20 Continued on next page. Johnson Controls Unitary Products 5 923178-UTG-B-0114 HEAT PUMPS (Continued) Model of Outdoor Unit DHMF09CSM42Q1 DHMF12CSM42Q1 DHMF18CSM42Q1 GREE GREE MITSUBISHI SANYO Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary L.R.A. (A) 16.50 16.50 27 41 Compressor RLA(A) 6.22 6.22 10.86 11.38 1630 Compressor Manufacturer/trademark Compressor Type Compressor Power Input (W) Throttling Method EXV 14 ~ 75 5 ~ 115 14 ~ 75 5 ~ 115 14 ~ 75 5 ~ 115 14 ~ 75 Working Temp Range (°C) -15 ~ 46 -10 ~ 24 -15 ~ 46 -10 ~ 24 -15 ~ 46 -10 ~ 24 -15 ~ 46 -10 ~ 24 Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter (inch) Φ 0.276 Φ 0.276 Φ 0.276 Pipe Diameter (mm) φ7 φ7 φ7 φ7 Rows-Fin Gap (inch) 1 - 0.055 2 - 0.055 2 - 0.055 2 - 0.055 Aluminum Fin-copper Tube Aluminum Fin-copper Tube Φ 0.276 1-1.4 2-1.4 2-1.4 2-1.4 Coil length (l) x height (H) x coil width (L) (inch) 25.5 × 20.8 × 0.8 25.5 × 20.8 × 1.5 33.0 × 26.0 × 1.5 33.6 × 26.0 × 1.5 Coil length (l) x height (H) x coil width (L) (mm) 647 × 19.05 × 528 647 × 38.1 × 528 837 × 38.1 × 660 853 × 38.1 × 660 Fan Motor Speed (rpm) 880±20 880±20 690 690 Output of Fan Motor (W) 21 21 60 60 0.25 0.25 0.62 0.62 Fan Motor RLA(A) Fan Motor Capacitor (uF) Outdoor Unit 1245 Capillary 5 ~ 115 Rows-Fin Gap (mm) Connection Pipe 950 Capillary Working Temp Range (oF) Condenser 6 950 Capillary DHMF24CSM42Q1 Fuse (A) 2 2 3 3.5 15A 15A 25A 25A Air Flow Volume of Outdoor Unit (CFM) 944 944 1887 1887 Air Flow Volume of Outdoor Unit (m3/h) 1600 1600 3200 3200 Fan Type-Piece Axial-flow-1 Axial-flow-1 Axial-flow-1 Axial-flow-1 Fan Diameter (inch) 14.6 14.6 20.5 20.5 Fan Diameter (mm) 370 370 520 520 Defrosting Method Automatic Defrosting Automatic Defrosting Automatic Defrosting Automatic Defrosting Climate Type T1 T1 T1 T1 Permissible Excessive Operating Pressure for the Discharge Side (PSI) 624 624 624 624 Permissible Excessive Operating Pressure for the Discharge Side (MPa) 4.3 4.3 4.3 4.3 Permissible Excessive Operating Pressure for the Suction Side (PSI) 363 363 363 363 Permissible Excessive Operating Pressure for the Suction Side (MPa) 2.5 2.5 2.5 2.5 Sound Pressure Level dB (A) 49 52 56 56 Sound Power Level dB (A) 59 62 66 56 Dimension (W/D/H) (mm) 28.0 × 12.5 × 21.7 28.0 × 12.5 × 21.7 37.9 × 15.6 × 27.6 37.9 × 15.6 × 27.6 Dimension (W/D/H) (mm) 711 × 318 × 551 711 × 318 × 551 963 × 396 × 701 963 × 396 × 701 Dimension of Package (L/W/H) (inch) 30.4 × 13.7 × 23.3 30.4 × 13.7 × 23.3 40.4 × 17.9 × 28.9 40.4 × 17.9 × 28.9 Dimension of Package (L/W/H) (mm) 771 × 348 × 592 771 × 348 × 592 1026 × 455 × 735 1026 × 455 × 735 Net Weight /Gross Weight (lbs) 64 / 73 68 / 77 106 / 117 115 / 126 Net Weight /Gross Weight (kg) 29 / 33 31 / 35 48 / 53 52 / 57 Refrigerant Charge (oz) 26.1 35.3 44.1 54.7 Refrigerant Charge (kg) 0.74 1.00 1.25 1.55 MCA 10.0 10.0 15.0 16.0 MOP 25.0 15.0 15.0 25.0 Length (ft) 25 25 25 25 Length (m) 7.5 7.5 7.5 7.5 Gas additional charge (oz/ft) 0.2 0.2 0.2 0.2 Gas additional charge (g/m) 20 20 20 20 Φ 1/4 Φ 1/4 Φ 1/4 Φ 1/4 Outer Diameter Liquid Pipe (inch) φ6 φ6 φ6 φ6 Outer Diameter Gas Pipe (inch) Φ 3/8 Φ 3/8 Φ 1/2 Φ 1/2 Outer Diameter Gas Pipe (mm) φ9.52 φ9.52 φ12 φ12 32.8 32.8 32.8 32.8 9.9 Outer Diameter Liquid Pipe (mm) Max Height Distance (ft) Max Height Distance (m) 9.9 9.9 9.9 Max Length Distance (ft) 49.2 49.2 82 82 Max Length Distance (m) 14.9 14.9 24.9 24.9 Johnson Controls Unitary Products 923178-UTG-B-0114 PRODUCT OPERATION CHARACTERISTIC CURVES 09K 12K Cooling Heating 10 8 9 7 8 6 7 5 Current(A) Current(A) 6 5 4 Condition Indoor:DB 80.6°F WB66.2°F Indoor air flow: Super High Pipe length:24.6ft 3 2 4 3 Condition Indoor:DB 68°F Indoor air flow: Super High Pipe length:24.6ft 2 1 1 0 0 0 20 40 60 80 100 0 120 20 40 Compressor Frequency(Hz) 60 80 100 120 Compressor Frequency(Hz) 18K Cooling 10 9 Heating 8 12 7 10 Current(A) Current(A) 6 5 4 Condition Indoor:DB 80.6°F WB66.2°F Indoor air flow: Super High Pipe length:24.6ft 3 2 8 6 Condition Indoor:DB 68°F Indoor air flow: Super High Pipe length:24.6ft 4 2 1 0 0 0 20 40 60 80 Compressor Frequency(Hz) Johnson Controls Unitary Products 100 120 0 20 40 60 80 100 120 Compressor Frequency(Hz) 7 923178-UTG-B-0114 24K Cooling Heating 14 14 12 12 10 10 8 8 6 6 4 2 2 0 0 0 20 40 Condition Indoor:DB 68°F Indoor air flow: Super High Pipe length:24.6ft 4 Condition Indoor:DB 80.6°F WB66.2°F Indoor air flow: Super High Pipe length:24.6ft 0 60 20 40 60 80 100 120 Compressor Frequency(Hz) Compressor Frequency(Hz) PRODUCT CAPACITY VARIATION RATIO 09K 12K Heating 110 120 100 100 90 80 Capacity ratio(%) Capacity ratio(%) Cooling 80 70 Condition Indoor:DB 80.6°F WB66.2°F Indoor air flow: Super High Pipe length:24.6ft 60 60 40 Condition Indoor:DB 68°F Indoor air flow: Super High Pipe length:24.6ft 20 0 50 90 95 100 105 110 115 5 10 15 Outdoor temp. (°F) 20 25 30 35 40 45 50 Outdoor temp. (°F) 18K 24K110 105 100 100 90 85 80 75 70 Conditions Indoor: DB 80.6°F WB66.2°F Indoor air flow : High Pipe length : 24.6ft 65 60 55 95 100 Outdoor temp. (˚F) 8 90 80 70 60 Condition Indoor:DB 68°F Indoor air flow: Super High Pipe length:24.6ft 50 40 50 90 Capacity ratio (%) Capacity ratio (%) 95 105 110 5 10 15 20 25 30 35 40 45 50 Outdoor temp. (˚F) Johnson Controls Unitary Products 923178-UTG-B-0114 OPERATION DATA Temperature Condition (°F) Model name Standard Pressure P (MPa) Heat Exchanger Pipe Temperature T1 (°F) T2 (°F) Indoor Fan Mode Outdoor Fan Compressor Mode Frequency (Hz) Indoor Outdoor 80/66.9 80/66.9 80/66.9 80/66.9 95/75 95/75 95/75 95/75 09K 12K 18K 24K 0.9 to 1.1 0.9 to 1.1 0.9 to 1.1 0.9 to 1.1 COOLING 53.6 to 57.2 53.6 to 57.2 53.6 to 57.2 53.6 to 57.2 158 to 104 158 to 104 176 to 104 176 to 104 Super High Super High Super High Super High High High High High 73 71 75 89 70/60 70/60 70/60 70/60 46.9/43 46.9/43 46.9/43 46.9/43 09K 12K 18K 24K 2.5 to 2.7 2.5 to 2.7 2.2 to 2.4 2.2 to 2.4 HEATING 158 to 95 158 to 95 158 to 104 158 to 104 35.6 to 39.2 35.6 to 39.2 33.8 to 41.0 33.8 to 41.0 Super High Super High Super High Super High High High High High 76 76 90 87 Notes: Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent. (Thermistor thermometer). Connecting piping condition: 24.6 ft. P: pressure of air pipe connected to the indoor and outdoor units (gas valve side), T1: Inlet and outlet temperature for evaporator, T2: Inlet and outlet temperature for condenser. SOUND DATA 09K 12K Indoor side noise when blowing Outdoor side noise 60 60 40 Noice/dB(A) Noice/dB(A) 50 30 20 50 40 30 10 20 0 low High Middle 0 Super High Indoor Fan Motor Rotating Speed 09K 20 40 60 80 100 Compressor frequency/Hz 12K 09K 12K 18K 24K Indoor side noise when blowing Outdoor side noise 60 60 50 40 Noice/dB(A) Noice/dB(A) 50 30 20 10 0 low Middle High Super High Indoor Fan Motor Rotating Speed 18K Johnson Controls Unitary Products 24K 40 30 20 0 20 40 60 80 100 Compressor frequency/Hz 18 24K 9 923178-UTG-B-0114 PRODUCT CONSTUCTION VIEW & DIMENSIONS A 09K 12K B 5.0 21.6 3.7 C 18K 5.5 21.3 7.2 24K 5.1 7.6 27.0 Indoor Unit Dimensions Model Size Unit Gross Weight A B C 30.3 (770) 7.9 (201) 11.1 (282) 18K 34.1 (866) 8.5 (216) 24K 39.7 (1008) 8.7 (221) 09K 12K Air Conditioner Heat Pump 25 lbs (11.5 kg) 25 lbs (11.5 kg) 27 lbs (12 kg) 27 lbs (12 kg) 12.0 (305) 35 lbs (16 kg) 35 lbs (16 kg) 12.4 (315) 44 lbs (20 kg) 44 lbs (20 kg) E F C D G B A Outdoor Unit Dimensions Model Size 09K 12K 18K 24K 10 A B 28.0 (711 ) 12.5 (318) 37.9 (963) 15.6 (396 ) C D E F G 21.7 (551) 11.8 (300) 10.8 (274) 25.9 (658) 18.5 (470) 27.6 (701) 14.4 (366) 13.4 (340) 35.0 (889) 22.0 (559) Unit Gross Weight Air Conditioner Heat Pump 73 lbs (33 kg) 73 lbs (33 kg) 77 lbs (35 kg) 77 lbs (35 kg) 115 lbs (52 kg) 117 lbs (53 kg) 123 lbs (56 kg) 126 lbs (57 kg) Johnson Controls Unitary Products 923178-UTG-B-0114 REFRIGERANT SYSTEM DIAGRAM 09K/12K/18K Cooling Only Models INDOOR UNIT OUTDOOR UNIT GAS SIDE 3-WAY VALVE Muffler Discharge HEAT EXCHANGE (EVAPORATOR) Accumlator Suction COMPRESSOR HEAT EXCHANGE (CONDENSER) LIQUID SIDE 2-WAY VALVE Capillary Strainer COOLING See Page 12 for notes. 09K/12K/18K Heat Pumps INDOOR UNIT OUTDOOR UNIT GAS SIDE 3-WAY VALVE 4-Way valve Muffler Discharge HEAT EXCHANGE (EVAPORATOR) Suction Accumlator COMPRESSOR HEAT EXCHANGE (CONDENSER) LIQUID SIDE 2-WAY VALVE Strainer Capillary Strainer COOLING HEATING See Page 12 for notes. Johnson Controls Unitary Products 11 923178-UTG-B-0114 24K Cooling Only Models INDOOR UNIT OUTDOOR UNIT GAS SIDE 3-WAY VALVE Muffler Discharge HEAT EXCHANGE (EVAPORATOR) Accumlator Suction COMPRESSOR HEAT EXCHANGE (CONDENSER) LIQUID SIDE Electron expansion valve 2-WAY VALVE Strainer COOLING See below for notes. 24K Heat Pumps INDOOR UNIT OUTDOOR UNIT GAS SIDE 3-WAY VALVE 4-Way valve Muffler Discharge HEAT EXCHANGE (EVAPORATOR) Suction Accumlator COMPRESSOR LIQUID SIDE 2-WAY VALVE HEAT EXCHANGE (CONDENSER) Strainer Electron expansion valve Strainer COOLING HEATING NOTES: Refrigerant pipe diameter Liquid: 1/4” (0.24 inch) Gas: 3/8” (0.37 inch)(09K 12K) Gas: 1/2” (0.47 inch)(18K 24K) 12 Johnson Controls Unitary Products 923178-UTG-B-0114 WIRING DIAGRAM Electrical Data Symbol Color Symbol Symbol Color Symbol Symbol Part Name BU BlUE BN BROWN YE YELLOW GN GREEN / / RD RED BK BLACK / / YEGN YELLOW GREEN / / / / Symbol Part Name Symbol Color Symbol Symbol Color Symbol C1 CBB61 BN BROWN WH WHITE C2 CBB65 BU BLUE YE YELLOW INDOOR UNIT PROTECTIVE EARTH OUTDOOR UNIT SAT OVERLOAD BK BLACK RD RED COMP COMPRESSOR OG ORANGE YEGN YELLOW GREEN PROTECTIVE EARTH WH WHITE / / Electrical Wiring 09K & 12K Outdoor Air Conditioners Johnson Controls Unitary Products 13 923178-UTG-B-0114 09K & 12K Indoor Air Conditioners 18K & 24K Outdoor Air Conditioners 14 Johnson Controls Unitary Products 923178-UTG-B-0114 18K & 24K Indoor Air Conditioners 09K & 12K Outdoor Heat Pumps Johnson Controls Unitary Products 15 923178-UTG-B-0114 09K & 12K Indoor Heat Pumps 18K & 24K Outdoor Heat Pumps 16 Johnson Controls Unitary Products 923178-UTG-B-0114 18K 24K 18K & 24K Indoor Heat Pumps DESCRIPTION OF EACH CONTROL OPERATION Temperature & Current Parameters • • • • • • • Indoor preset temperature (Tpreset) Indoor ambient temperature (Tamb.) Evaporator coil temperature (Tevap) Condenser coil temperature (Toutdoor pipe) Defrost compensation temperature (Tcompensation) Outdoor ambient temperature (Toutdoor amb) Measured temperature of outdoor condensing coil under cooling mode and measured temperature of indoor evaporator coil under heating mode (Ttube). • Indoor ambient temperature (Tindoor amb) Basic Functions Once energized, the compressor should never be restarted within less than 3 minutes. In a situation where memory function is available when energized for the first time, if the compressor is at stop before de-energized, it will re-start without a 3-minute lag. If it has been in operation before de- energized, the compressor will start with a 3-minute lag. Once started, the compressor will not be stopped within 6 minutes regardless of changes in room temperature. Cooling Mode 1. Cooling Mode Operation • When Tamb Tpreset, cooling mode is activated. The indoor fan, outdoor fan and the compressor will operate simultaneously. The indoor fan will run at preset speed. • When Tamb Tpreset - 3.6,°F the compressor will stop, the outdoor fan will stop with a time lag of 60 seconds, and the indoor fan will run at preset speed. • When Tpreset - 3.6°F < Tamb. < Tpreset + 1.8°F, the unit will remain at its previous state. In cooling mode, the four-way valve will be de-energized and temperature can be set within a range from 61 to 86°F. If the compressor stops running, the indoor fan and the swing device will operate at original state. Johnson Controls Unitary Products Tamb. Start cooling Tpreset Original working state Tpreset +3.6 ºF Stop cooling 6 minutes 3 minutes 6 minutes Compressor Outdoor fan Indoor fan Preset fan speed Run Stop 2. Protection – Cooling Mode • Antifreeze protection - In cooling and dehumidification mode, antifreeze protection is activated 6 minutes after the compressor has started if one of followings occur: T evap 35.6 °F, the compressor will operate at reduced frequency. T evap 30.2 °F is detected for a duration of 3 minutes, the compressor will stop and after 60 seconds, the outdoor fan will stop. In cooling mode, the indoor fan and the swing motor will remain at the original state. T evap. 42.8 °F and the compressor has remained in OFF mode for at least 3 minutes, the compressor will resume its original operation state. • Total current up and frequency down protection if the followings occur: Itotal 16A, the compressor frequency will start to increase Itotal 17A, the compressor frequency will not increase Itotal 18A, the compressor will run at reduced frequency Itotal 20A, the compressor will immediately stop and the outdoor fan will stop after 60 seconds 17 923178-UTG-B-0114 Dehumidification Mode 1. Dehumidification Mode Operation • When Tamb > Tpreset + 1.8 °F, cooling and dehumidification mode will be activated. The compressor and the outdoor fan will operate while the indoor fan runs at low speed. • When Tpreset - 3.6 °F Tamb Tpreset + 1.8°F, the compressor remains at its original operation state. • When Tamb. < Tpreset - 3.6°F, the compressor will stop, the outdoor fan will stop after 60 seconds and the indoor fan will operate at low speed. 2. Protection – Dehumidification Mode Protection is the same as that under cooling mode section. Heating Mode 1. Heating Mode Operation • When Tamb. Tpreset + 3.6°F, heating mode is activated. The four-way valve, the compressor and the outdoor fan will operate simultaneously. The indoor fan will run at preset speed defined under “cold air prevention”. • When Tamb. Tpreset + 9°F, the compressor will stop, the outdoor fan will stop after 60 seconds, and the indoor fan will continue to run at low speed for 60 seconds more. • When Tpreset + 3.6°F 35.6°F, Tcompensation = 0°F; Toutdoor pipe ≤35.6°F, Tcompensation = 5.4°F When in defrost mode the following will occur in the order described: a. The indoor fan and compressor stop running b. The outdoor fan will stop running after 60 seconds. c. 30seconds later, the four-way valve will close. d. After 30 seconds, the compressor’s frequency is increased to defrost frequency. e. When the compressor has operated in defrost mode for 10 minutes, or Toutdoor pipe ≥ 50°F, the compressor will adjust to 46Hz. f. After 30 seconds, the compressor will stop. g. After another 30 seconds, the four-way valve will open. 18 h. After 60 seconds, the compressor and the outdoor unit fan will start running. The indoor fan will run under preset cold air prevention conditions. H1 will be displayed on the indoor unit display. Defrost frequency is 70Hz. 3. Protection – Heating Mode • Cold air prevention (Hot Heat Pump) - In heating mode, after the compressor is energized the indoor fan is delayed under these conditions to prevent discharging cold air: When Tindoor amb.<75°F if: Ttube≤104°F, the indoor fan will not run. The indoor fan will start running at low speed after 2 minutes. Within 2 minutes, if Ttube>104°F, the indoor fan will start running at low speed. After 1minute of operation at low speed, the indoor fan will run at preset speed. Within 1-minute of low speed operation or 2-minute non-operation, if Ttube>108°F, the fan will run at present speed. When Tindoor amb.≥75°F if: Ttube≤108°F, the indoor fan will run at low speed. After one minute of operation, the indoor fan will run at preset speed. Within one-minute of low speed operation, if Ttube>104°F, the indoor fan will run at preset speed. Total current up and frequency down protection occurs: When Itotal≤16A, compressor frequency can increase When Itotal≥17A, compressor frequency is not allowed to increase When Itotal≥18A, the compressor runs at reduced frequency When Itotal≥20A, the compressor stops running and the outdoor fan stops running after 60 seconds. Fan Mode In this mode, the indoor fan will run at preset speed. The compressor, the outdoor fan and the four-way valve will not be running. 1. In fan mode, temperature can be set within a range of 61 86°F. AUTO Mode 1. AUTO Mode Operation In AUTO mode, the default cooling setpoint temperature Tpreset is 77°F and the default heating setpoint temperature Tpreset is 68°F. Once activated, the following will occur under these conditions: • When Tamb.≤71.6°F, heating mode is activated. • When 71.6°F< Tamb.<78.8°F, fan mode is activated and the fan icon is displayed on the indoor unit display. • When Tamb.≥78.8°F, cooling mode is activated. • When Tamb.≥Tpreset +1.8°F, the system runs in cooling mode. The preset temperature is 77°F; • When Tamb. ≤Tpreset-1.8°F, the compressor stops running, the outdoor fan stops running after 1 minute, and the indoor fan continues to run at a preset speed. • When Tpreset -1.8°F< Tamb.< Tpreset+1.8°F, the system continues to run normally. • When Tamb.≤Tpreset+3.6°F, heating mode is activated. • Tamb.≥Tpreset +9°F, the compressor stops running, the outdoor fan stops running after 1 minute, and the indoor fan continues to run for about 30 seconds before it stops. Johnson Controls Unitary Products 923178-UTG-B-0114 • When Tpreset +3.6°F< Tamb.< Tpreset+41°F, the system continues to run normally • When 71.6°F
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Author : ckobyk Create Date : 2014:01:10 15:00:21-06:00 Modify Date : 2014:01:20 08:07:00-06:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 10.0.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2014:01:20 08:07-06:00 Format : application/pdf Title : 923178-UTG-B-0114.fm Creator : ckobyk Document ID : uuid:339f37be-3f1f-4d54-b1f5-759729433b4a Instance ID : uuid:a50b4dcc-e3b4-4ed2-84fc-c54593e21c29 Page Layout : OneColumn Page Mode : UseThumbs Page Count : 34EXIF Metadata provided by EXIF.tools