York Predator Dm 078 Users Manual Y TG, Std. Eff. Sgl Pkg AC And Gas/Elec Units, S
DM 078 to the manual f1bb87ac-3d8d-4722-b74f-d9855f1c5b72
2015-02-02
: York Predator-Dm-078-Users-Manual york-predator-dm-078-users-manual-455138 york pdf
Open the PDF directly: View PDF .
Page Count: 48
Download | |
Open PDF In Browser | View PDF |
246645-YTG-C-0708 ® TECHNICAL GUIDE ® DESCRIPTION YORK® Predator® units are convertible single packages with a common footprint cabinet and common roof curb for all 6-1/2 through 12-1/2 ton models. All units have two compressors with independent refrigeration circuits to provide two stages of cooling. The units were designed for commercial applications and can be easily installed on a roof curb, slab, or frame. STANDARD EFFICIENCY SINGLE PACKAGE GAS/ELECTRIC UNITS All Predator® units are self-contained and assembled on rigid full perimeter base rails allowing for 3-way forklift access and overhead rigging. Every unit is completely charged, wired, piped, and tested at the factory to provide a quick and easy field installation. DM 078, 090, 102, 120 and 150 6-1/2, 7-1/2, 8-1/2, 10 and 12-1/2 NOMINAL TONS 9.0 EER All units are convertible between side and down airflow. A independent economizer design is used on side and down discharge applications, as well as all tonnage sizes. SINGLE PACKAGE AIR CONDITIONERS AND Predator® units are available in the following configurations: cooling only, cooling with electric heat, and cooling with gas heat. Electric heaters are available as factoryinstalled options or field-installed accessories. Tested in accordance with: FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 246645-YTG-C-0708 TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Tbl. # FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 11 ELECTRICAL DATA DM078 (6-1/2 TON) STD EFFICIENCY WITH PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . 18 12 ELECTRICAL DATA - DM090 (7-1/2 TON) STANDARD EFFICIENCY W/O PWRD CONV. OUTLET . . . . . . . . . . . . 19 13 ELECTRICAL DATA - DM090 (7-1/2 TON) STANDARD EFFICIENCY W/PWRD CONV. OUTLET . . . . . . . . . . . . . . 19 14 ELECTRICAL DATA DM102 (8-1/2 TON) STD EFFICIENCY W/O PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . . 20 15 ELECTRICAL DATA DM102 (8-1/2 TON) STD EFFICIENCY WITH PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . 20 16 ELECTRICAL DATA DM120 (10 TON) STD EFFICIENCY W/ O PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . . . . 21 17 ELECTRICAL DATA DM120 (10 TON) STD EFFICIENCY WITH PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . 21 18 ELECTRICAL DATA DM150 (12-1/2 TON) STD EFFICIENCY W/O PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . . 22 19 ELECTRICAL DATA DM150 (12-1/2 TON) STD EFFICIENCY W/PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . . . . 22 20 ELECTRIC HEAT MULTIPLIERS . . . . . . . . . . . . . . . . . . . . . 22 21 DM078 (6-1/2 TON) SIDE SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 22 DM090 (7-1/2 TON) SIDE SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 FACTORY INSTALLED OPTIONS . . . . . . . . . . . . . . . . . . . 5 FIELD INSTALLED ACCESSORIES . . . . . . . . . . . . . . . . . 6 NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . 46 LIST OF FIGURES Fig. # Pg. # 1 PREDATOR® COMPONENT LOCATION . . . . . . . . . . . . . 3 2 UNIT 4 POINT LOAD . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 3 UNIT CENTER OF GRAVITY . . . . . . . . . . . . . . . . . . . . . 35 4 UNIT 6 POINT LOAD . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 5 UNIT DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 6 PREDATOR® ROOF CURB DIMENSIONS . . . . . . . . . . 37 7 SUNLINE™ TO PREDATOR® TRANSITION ROOF CURBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 8 BOTTOM DUCT OPENINGS (FROM ABOVE) . . . . . . . . 38 9 REAR DUCT DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . 39 Pg. # 10 DOWNFLOW ECONOMIZER HOOD DETAIL . . . . . . . . 39 11 FACTORY INSTALLED DOWNFLOW ECONOMIZER . . 40 12 FIELD INSTALLED DOWNFLOW ECONOMIZER W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 23 DM102 (8-1/2 TON) SIDE SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 13 FIELD INSTALLED HORIZONTAL ECONOMIZER W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 24 DM120 (10 TON) SIDE SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 14 SLAB ECONOMIZER DOWNFLOW W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 25 DM150 (12-1/2 TON) SIDE SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 15 SLAB ECONOMIZER END RETURN W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 26 DM078 (6-1/2 TON) DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 16 COOLING UNIT WITH GAS HEAT WIRING 230 VOLT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 27 DM090 (7-1/2 TON) DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 17 COOLING UNIT WITH/WITHOUT ELECTRIC HEAT WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 28 DM102 (8-1/2 TON) DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 18 COOLING UNIT WITH GAS HEAT WIRING 460, 575 VOLT AND 50 HZ DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . 45 29 DM120 (10 TON) DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 30 DM150 (12-1/2 TON) DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 31 ADDITIONAL STATIC RESISTANCE DM078, 120 AND 150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 32 ADDITIONAL STATIC RESISTANCE DM090, 102 . . . . . . . 33 LIST OF TABLES Tbl. # Pg. # 1 ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 2 DM PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 3 DM CAPACITY RATINGS . . . . . . . . . . . . . . . . . . . . . . . . . . .12 4 UNIT VOLTAGE LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . .12 5 COOLING CAPACITY DM078 (6-1/2 TON) UNIT . . . . . . . .13 6 COOLING CAPACITY DM090 (7-1/2 TON) UNIT . . . . . . . .14 7 COOLING CAPACITY DM102 (8-1/2 TON) UNIT . . . . . . . .15 8 COOLING CAPACITY DM120 (10 TON) UNIT . . . . . . . . . .16 9 COOLING CAPACITY DM150 (12-1/2 TON) UNIT . . . . . . .17 10 ELECTRICAL DATA DM078 (6-1/2 TON) STD EFFICIENCY W/O PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . . .18 2 33 ELECTRIC HEAT MINIMUM SUPPLY AIR CFM . . . . . . . . 34 34 INDOOR BLOWER SPECIFICATIONS . . . . . . . . . . . . . . . . 34 35 POWER EXHAUST SPECIFICATIONS . . . . . . . . . . . . . . . . 34 36 4 POINT LOAD WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 37 6 POINT LOAD WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 38 UNIT WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 39 UNIT HEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 40 UNIT CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 41 ECONOMIZER USAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Johnson Controls Unitary Products 246645-YTG-C-0708 Simplicity™ control board Filter access Disconnect location w/screw connector for T-stat (2” throw-away) wiring and network connections (optional disconnect switch) Filter drier (solid core) Terminal block for hi-voltage connection Condenser section Second model nameplate inside hinged access panel Slide-out motor and blower assembly for easy adjustment and service Dual stage cooling for maximum comfort Belt-drive blower motor Power ventor motor Compressor #2 access (highefficiency compressor w/crankcase heater) 20-gauge aluminized steel tubular heat exchanger for long life (stainless steel option) Base rails w/forklift slots (three sides) and lifting holes Two-stage gas heating to maintain warm, comfortable temperature Roof curbs in eight- and fourteen-inch heights. Roof curbs for transitioning from York Sunline™ footprint to the ZH Series footprints are also available (field-installed accessory) FIGURE 1 - Slide-out drain pan with steel 3/4” NPT, female connection Toolless door latch Side entry power and control wiring knockouts • Compressor #1 access (high-efficiency compressor w/crankcase heater) PREDATOR® COMPONENT LOCATION (DM 120 SHOWN) FEATURES • Intelligent control board for safe and efficient operation Service windows have been placed in both condenser section walls. Rotation of the cover allows easy access to the condenser coils for cleaning or inspection. Standard Efficiency– All standard efficiency units have a minimum EER of 9.0. Gas/electric units have electronic spark ignition and power vented combustion with steady state efficiencies of 80%. Both the unit control board and ignition control board utilize flash codes to aid in diagnosis of unit malfunctions. Unique alarm codes quickly identify the source of the unit alarm. Service Friendly – The Predator® incorporates a number of enhancements which improve serviceability. All units use the same standard filter size. This standardization removes any confusion on which filter sizes are needed for replacement. The motor and blower slide out of the unit as a common assembly. This facilitates greater access to all the indoor airflow components, thus simplifying maintenance and adjustment. Service time is reduced through the use of hinged, toolless panels. Such panels provide access to frequently inspected components and areas, including the control box, compressors, filters, indoor motor & blower, and the heating section. The panels are screwed in place at the factory to prevent access by children or other unauthorized persons. It is recommended that the panels be secured with screws once service is complete. Johnson Controls Unitary Products The non-corrosive drain pan slides out of the unit to permit easy cleaning. The drain pan is accessed by removing the drain pan cover plate on the rear of the unit. Once the plate is removed, the drain pan slides out through the rear of the unit. All Predator® units have a second model nameplate located inside the control access door. This is to prevent deterioration of the nameplate through weathering. • Environmentally Aware – For improved Indoor Air Quality, foil faced insulation is used exclusively throughout the units. 3 246645-YTG-C-0708 • Balanced Heating – The Predator® offers “Ultimate Heating Comfort” with a balance between 1st and 2nd stage gas heating. The 1st stage of a gas heat Predator® unit provides 60% of the heating capacity. Balanced heating allows the unit to better maintain desired temperatures. • Convertible Airflow Design – The side duct openings are covered when they leave the factory. If a side supply/return is desired, the installer simply removes the two side duct covers from the outside of the unit and installs them over the down shot openings. No panel cutting is required. Convertible airflow design allows maximum field flexibility and minimum inventory. • • System Protection - Suction line freezestats are supplied on all units to protect against loss of charge and coil frosting when the economizer operates at low outdoor air temperatures while the compressors are running. Every unit has solid-core liquid line filter-driers and high and lowpressure switches. Internal compressor protection is standard on all compressors. Crankcase heaters are standard on reciprocating compressors. Scroll compressors do not require crankcase heaters. Phase Monitors are standard on units with scroll compressors. This accessory monitors the incoming power to the unit and protects the unit from phase loss and reversed phase rotation. • • Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0°F outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temperature is low or when free cooling is available. Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti-short cycle delay can be temporarily overridden with the push of a button. On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and low-pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power. • Reliable – From the beginning – All units undergo computer automated testing before they leave the factory. Units are tested for refrigerant charge and pressure, unit amperage, and 100% functionality. For the long term – All Predator® units are painted with a long lasting, powder paint that stands up over the life of the unit. The paint used has been proven by a 1000 hour salt spray test. • Flexible Placement – All models and configurations share the same cabinet/footprint and thus the same roof curb. You have the flexibility to set one curb and choose the correct tonnage size and heating option after the internal loads have been determined. To further simplify planning and installation, Predator® cabinets are designed to fit your roof. With the optional roof curb, the unit ductwork is designed to fit around 24” on-center joists or between 48” on-center joists. Advanced Controls - Simplicity™ control boards have standardized a number of features previously available only as options or by utilizing additional controls. • 4 • The drain pan can be rotated to drain to either the front or the rear of the unit. Additionally, the drain pan can be piped to drain through the roof curb. As it is sometimes difficult to have a level installation, the drain pan features a generous slope to ensure proper drainage. • Full Perimeter Base Rails – The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails offer forklift access from 3 sides, and rigging holes are available so that an overhead crane can be used to place the units on a roof. • Easy Installation – Gas and electric utility knockouts are supplied in the unit underside as well as the side of the unit. A clearly identified location is provided to mount a field supplied electrical disconnect switch. Utility connections can be made quickly and with a minimum amount of field labor. Fan Delays - Fan on and fan off delays are fully programmable. Furthermore, the heating and cooling fan delay times are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat. • • Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit control board will alarm on ignition failures, compressor lockouts and repeated limit switch trips. Wide Range of Indoor Airflows – All indoor fan motors are belt-drive type providing maximum flexibility to handle most airflow requirements. For high static applications, factory installed alternate indoor fan motors are available. With the optional indoor fan motor, all units can supply nominal airflow at a minimum of 1.5” ESP. • • Nuisance Trip Protection and Strikes - To prevent nuisance trouble calls, the control board uses a “three times, you’re out” philosophy. The high and low-pressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the associated compressor. Warranty - All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements each carry a 5-year warranty. Aluminized steel and stainless steel tubular heat exchangers carry an additional 10-year warranty. All units are shipped with 2” filters installed. Johnson Controls Unitary Products 246645-YTG-C-0708 FACTORY INSTALLED OPTIONS ers close. The changeover from mechanical refrigeration to economizer operation is regulated by the standard single enthalpy input. There is an optional input dual dry bulb available. To meet regulated air standards, the economizer control accepts an optional CO2 input for demand ventilation. With single enthalpy input, the economizer control monitors outdoor air. The dual enthalpy kit provides a second input used to monitor the return air. With a dual input kit installed, the economizer control compares the values of the two enthalpy or temperature inputs and positions the dampers to provide the maximum efficiency possible. YORK® offers several equipment options factory installed, for the Predator® line. • Optional Factory Installed Economizers - Predator units offer a variety of optional factory installed economizers with low leak dampers. The outdoor air enthalpy sensor enables economizer operation if the outdoor enthalpy is less than the setpoint of the economizer logic module. See Table 41 to determine the correct economizer for your application. • • • • Downflow Economizer - (With barometric relief) The economizer is provided with a single enthalpy input. The economizer is 2% low leakage type, and is shipped installed and wired. The installer needs only to assemble and mount the outdoor air hood (Provided). The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is regulated by the standard single enthalpy input. There is an optional input dual dry bulb available. To meet regulated air standards, the economizer control accepts an optional CO2 input for demand ventilation. With single enthalpy input, the economizer control monitors outdoor air. The dual enthalpy kit provides a second input used to monitor the return air. With a dual input kit installed, the economizer control compares the values of the two enthalpy or temperature inputs and positions the dampers to provide the maximum efficiency possible. • Power Exhaust (Downflow only) - This accessory installs in the unit with a down flow economizer. • Motorized Outdoor Air Damper - The motorized outdoor air damper includes a slide-in/plug-in damper assembly with an outdoor air hood and filters. The outdoor air dampers open to the preset position when the indoor fan motor is energized. The damper has a range of 0% to 100% outdoor air entry. Factory installed option or field installed accessory. • Alternate Indoor Blower Motor - For applications with high static restrictions, units are offered with optional indoor motors that provide higher static output and/or higher airflow, depending upon the installer’s needs. • Aluminized Steel Gas Heat Exchanger - For applications in non-corrosive environments. • Stainless Steel Gas Heat Exchanger - For applications in corrosive environments, this option provides a full stainless steel heat exchanger assembly. Horizontal Economizer - (Without barometric relief) - All features of the downflow economizer exist except you must order the duct mount barometric relief separately. You must order a 1EH0408 if you are installing a power exhaust. You can order a 1RD0411 Barometric Relief for horizontal flow economizers only. • Stainless Steel Drain Pan - An optional rust-proof stainless steel drain pan is available to provide years of trouble-free operation in corrosive environments. • Electric Heaters - The electric heaters range from 9kW to 54kW and are available in all the voltage options of the base units. All heaters are dual staged. All heaters are intended for single point power supply. BAS Ready Economizer -(With barometric relief) - The economizer is provided with a Belimo actuator that requires a 0-10V DC input from an external source (i.e., field installed building automation system controller). Power exhaust options are available. The economizer is 2% low leakage type with spring return and fully modulating dampers capable of introducing up to 100% outside air. Also include 2” pleated filters. • Disconnect Switch - For gas heat units and cooling units with electric heat, an HACR breaker sized to the unit is provided. For cooling only units, a switch sized to the largest electric heat available for the particular unit is provided. Factory installed option only. • Convenience Outlet - (Non-Powered /Powered) - This option locates a 120V single-phase GFCI outlet with cover, on the corner of the unit housing adjacent to the compressors. The “Non-powered” option requires the installer to provide the 120V single-phase power source and wiring. The “Powered” option is powered by a stepdown transformer in the unit. Factory installed option only. • Smoke Detectors - The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. Available for both the supply and/or return air. Slab Economizer for Energy Recovery Ventilators(With barometric relief and Fresh Air Hood) - The economizer is provided with a single enthalpy input. The economizer is 2% low leakage type, and is shipped installed and wired. The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air damp- Johnson Controls Unitary Products 5 246645-YTG-C-0708 Factory installed smoke detectors in the return air, may be subjected to freezing temperatures during "off" times due to out side air infiltration. These smoke detectors have an operational limit of 32 °F to 131°F. Smoke detectors installed in areas that could be out side those limitations will have to be moved to prevent having false alarms. • Simplicity™ INTELLI-Comfort™ with ModLINC Control - The York® Simplicity™ INTELLI-Comfort™ with ModLINC control is factory installed. It includes all the features of the INTELLI-Comfort™ control with an additional control to translate communications from MODBUS to the BACnet MSTP protocol. • Novar® BAS Control - The Novar® ETC-3 building automation system controller is factory installed. Incudes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. • Johnson Controls BAS Control - The Johnson Control YK-UNT-1126 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. • CPC BAS Control - The Computer Process Controls Model 810-3060 ARTC Advanced Rooftop building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch and air proving switch. • Honeywell BAS Control - The Honeywell W7750C building automation system controller is factory installed. Includes air supply sensor, return air sensor, dirty filter indicator switch, and air proving switch. • York Commercial Comfort System (YCCS) - Provides rooftop system integration for YCCS single zone and change-over bypass systems. • Phase Monitors - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-of phase condition. (Standard on units with Scroll Compressors.) • Coil Guard - Customers can purchase a coil guard kit to protect the condenser coil from damage. Additionally, this kit stops animals and foreign objects from entering the space between the inner condenser coil and the main cabinet. This is not a hail guard kit. • Dirty Filter Switch - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory. • Technicoat Condenser Coils - The condenser coils are coated with a phenolic coating for protection against corrosion due to harsh environments. • Technicoat Evaporator Coil - The evaporator coils are coated with a phenolic coating for protection against corrosion due to harsh environments. FIELD INSTALLED ACCESSORIES BAS - Building Automation System Controls Simplicity™ INTELLI-Comfort™ Control - The York® Simplicity™ INTELLI-Comfort™ control is factory installed. It includes a supply air sensor, a return air sensor, and an outside air sensor. There are provisions for a field installed dirty filter indicator switch, an air-proving switch, an Outside Air Humidity sensor, a Return Air Humidity sensor, an Inside IAQ sensor, and an Outside Air IAQ sensor. Construction mode operation, 365-day real time clock with 7 day programming plus holiday scheduling is built-in. Two different modes of demand ventilation are achieved through the INTELLI-Comfort™ using CO2 sensors. It uses an inside CO2 sensor to perform Demand Ventilation. It can also use an Outside CO2 sensor to perform Differential Demand Ventilation. It uses a Patented Comfort Ventilation algorithm to provide comfortable ventilation air temperature. The patented economizer-loading algorithm will protect the equipment when harsh operating conditions exist. Humidity in the occupied space or return duct can be monitored and controlled via humidity sensors and the onboard connection for hot gas re-heat system. It uses the INTELLI-Start™ algorithm to maximize energy savings by recovering the building from the Unoccupied Setpoints to the Occupied Setpoints just in time for the Occupied Time Period to begin. The Simplicity™ INTELLI-Comfort™ balances space temperature, ventilation air temperature, CO2 and humidity for ultimate comfort. • Downflow Economizer - (With barometric relief) - The economizer is provided with a single enthalpy input. The economizer is 2% low leakage type. The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is regulated by the standard single enthalpy input. There is an optional input dual dry bulb available. To meet regulated air standards, the economizer control accepts an optional CO2 input for demand ventilation. With single enthalpy input, the economizer control monitors outdoor air. The dual enthalpy kit provides a second input used to monitor the return air. With a dual input kit installed, the economizer control compares the values of the two enthalpy or temperature inputs and positions the dampers to provide the maximum efficiency possible • Horizontal Economizer - (Without barometric relief) All features of the downflow economizer exist except you must order the duct mount barometric relief separately. You must order a 1EH0408 if you are installing a power exhaust. You can order a 1RD0411 Barometric Relief for horizontal flow economizer. • Slab Economizer for Energy Recovery Ventilator(Without barometric relief or Fresh Air Hood) - The economizer is provided with a single enthalpy input. The • 6 YORK® offers several equipment accessories for field installation, for the Predator® line. Johnson Controls Unitary Products 246645-YTG-C-0708 economizer is 2% low leakage type. The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is regulated by the standard single enthalpy input. There is an optional input dual dry bulb available. To meet regulated air standards, the economizer control accepts an optional CO2 input for demand ventilation. With single enthalpy input, the economizer control monitors outdoor air. The dual enthalpy kit provides a second input used to monitor the return air. With a dual input kit installed, the economizer control compares the values of the two enthalpy or temperature inputs and positions the dampers to provide the maximum efficiency possible. You can order 1EH0409 Barometric Relief/FA Hood for field installations without an ERV. • Flue Exhaust Extension Kit - In locations with wind or weather conditions which may interfere with proper exhausting of furnace combustion products, this kit can be installed to prevent the flue exhaust from entering nearby fresh air intakes. • -60°F Gas Heat Kit - For installations which require gas heat units to perform in low ambient temperatures, a gas section heating kit is available. This kit provides electric heat in the gas heat controls section to ensure the gas valve and controls will continue to function properly at extremely low temperatures. • Gas Heat High Altitude Kit - This kit converts a gas heat unit to operate at high altitudes, 2,000 to 6,000 feet. Conversion kits are available for natural gas and propane. • Gas Heat Propane Conversion Kit - This kit converts a gas-fired heater from natural gas to propane. It contains the main burner orifices and gas valve replacement springs. • Dual Enthalpy Control, Accessory - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy. • • Barometric Relief Damper - Zero to 100% capacity barometric relief dampers for use with horizontal flow, or field installed slab economizers. Gas Piping Kit - Contains pipe nipples, fittings and gas cock required for gas supply connection with external shut off. • • Power Exhaust - This accessory installs in the unit with a down flow economizer. Power exhaust plugs into the connector in the unit bulkhead. You must purchase 1EH0408 barometric relief when applying to a horizontal flow application. Electric Heaters - The electric heaters range from 9 kW to 54kW and are available in all the voltage options of the base units. All heaters are dual staged. Cooling units include an adapter panel for easy installation of the electric heaters. Necessary hardware and connectors are included with the heaters. All heaters are intended for single point power supply. • Manual Outdoor Air Damper - Like the motorized outdoor air damper, each manual outdoor air damper includes a slide-in damper assembly with an outdoor air hood and filters. Customers have a choice of dampers with ranges of 0% to 100% or 0% to 35% outdoor air entry. • Low Limit / Compressor Lockout Kit • Motorized Outdoor Air Damper - The motorized outdoor air damper includes a slide-in/plug-in damper assembly with an outdoor air hood and filters. The outdoor air dampers open to the preset position when the indoor fan motor is energized. The damper has a range of 0% to 100% outdoor air entry. Factory installed option or field installed accessory. • Smoke Detectors - The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. • CO2 Sensor - Senses CO2 levels and automatically overrides the economizer when levels rise above the preset limits. • Dirty Filter Switch - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. • Coil Guard - Field installed decorative wire coil guard. • Hail Guard - This kit includes a sloped hood which installs over the outside condenser coil and prevents damage to the coil fins from hail strikes. Field installed accessory only. Johnson Controls Unitary Products 1. Compressor Lockout (CLO): To prevent mechanical (compressorized) operation of the unit during cold outdoor conditions where there is a risk of returning liquid refrigerant back to the compressors. 2. Low Limit Control (LLC): To prevent the supply air from dropping below a specified setpoint by utilizing the units first stage heating means when there is a demand for cooling during cold outside conditions. • Metal Frame Filter Kit - Metal frame with polyester filter medium. • Permanent Filters - Permanent filters are available. • Roof Curbs - The roof curbs have insulated decks and are shipped disassembled The roof curbs are available in 8” and 14” heights. For applications with security concerns, burglar bars are available for the duct openings of the roof curbs. • Roof Curb Transition - Single Piece Adapter (10” High) Roof curbs for transitioning from Sunline™ units to Predator® units. Fits 7.5 to 12.5 Sunline™ roof curbs only. • Burglar Bars - Mount in the supply and return openings to prevent entry into the duct work. • Thermostat - The units are designed to operate with 24volt electronic and electro-mechanical thermostats. All units (with or without an economizer) operate with twostage heat/two-stage cool or two-stage cooling only thermostats, depending upon unit configuration. 7 246645-YTG-C-0708 TABLE 1: ACCESSORIES Part Number Description Weight 1RC0470 Roof Curb, 8" Height 1RC0471 Roof Curb, 14" Height - 1RC0472 Roof Curb, Transition (7.5 T through 12.5 T) - 1BD0408 Burglar Bars, Downflow - 2TP04520925 Electric Heat 9kW 230V - 2TP04521825 Electric Heat 18kW 230V - 2TP04522425 Electric Heat 24kW 230V - 2TP04523625 Electric Heat 36kW 230V - 2TP04525425 Electric Heat 54kW 230V - 2TP04520946 Electric Heat 9kW 460V - 2TP04521846 Electric Heat 18kW 460V - 2TP04522446 Electric Heat 24kW 460V - 2TP04523646 Electric Heat 36kW 460V - 2TP04525446 Electric Heat 54kW 460V - 2TP04520958 Electric Heat 9kW 575V - 2TP04521858 Electric Heat 18kW 575V - 2TP04522458 Electric Heat 24kW 575V - 2TP04523658 Electric Heat 36kW 575V - 2TP04525458 Electric Heat 54kW 575V - 2TP04540925 Electric Heat 9kW 230V, 42" Tall Cabinet - 2TP04541825 Electric Heat 18kW 230V, 42" Tall Cabinet - 2TP04542425 Electric Heat 24kW 230V, 42" Tall Cabinet - 2TP04543625 Electric Heat 36kW 230V, 42" Tall Cabinet - 2TP04540946 Electric Heat 9kW 460V, 42" Tall Cabinet - 2TP04541846 Electric Heat 18kW 460V, 42" Tall Cabinet - 2TP04542446 Electric Heat 24kW 460V, 42" Tall Cabinet - 2TP04543646 Electric Heat 36kW 460V, 42" Tall Cabinet - 2TP04540958 Electric Heat 9kW 575V, 42" Tall Cabinet - 2TP04541858 Electric Heat 18kW 575V, 42" Tall Cabinet - 2TP04542458 Electric Heat 24kW 575V, 42" Tall Cabinet - 2TP04543658 Electric Heat 36kW 575V, 42" Tall Cabinet - 1FA0411 Manual Outside Air Damper 0-35%, Downflow (Incl. Hood, Damper & Filters, No Barometric Relief) - 1FA0412 Manual Outside Air Damper 0-100%, Downflow (Incl. Hood, Damper & Filters, No Barometric Relief) - 2MD04702724 Motorized Damper, Downflow (Incl. Hood, Damper & Filter, no Barometric Relief) - 2MD04703324 Motorized Damper, Horizontal (Incl. Hood, Damper & Filter, no Barometric Relief) 2EE04705424 Economizer, Downflow (Incl. Barometric Relief & All Hoods) 124 lbs. 2EE04705524 Economizer, Horizontal (Incl. Dampers & Hoods, no Barometric Relief) 97 lbs. 2EE04705224 Economizer, Slab, Downflow (Incl. Dampers only no Hoods or Barometric Relief) 2EE04705624 "Downflow Economizer, Slab type for ERV (no Barometric Relief or FA hood)", 42" Tall Cabinet - 2PE04703225 Power Exhaust, Downflow, 230V (For Units with Economizer only) - 2PE04703246 Power Exhaust, Downflow, 460V(For Units with Economizer only) - 2PE04703258 Power Exhaust, Downflow, 580V (For Units with Economizer only) - 2EC04700924 Dual Enthalpy Control (Use with Single Enthalpy Economizer) - 1EH0407 Hood Kit, Downflow Economizer (Included with all Downflow Economizers) 1RD0411 Barometric Relief Kit, Ductmount for Horizontal Application (Incl. Damper & Hood) 1EH0408 Barometric Relief Kit, Ductmount for Horizontal Application w/Power Exhaust (Incl. Damper & Hood) 1EH0409 Barometric Relief / Hood Kit, for Field Installed Slab Econ. w/o ERV (Incl. Barometric Relief & FA Hood) - 2AQ04700424 CO2 Detector Unit Mount - 2AQ04700324 CO2 Detector Space Mount - 2SD04700424 Smoke Detector, Supply or Return (Return Not Available with Horizontal Economizer) - 2MK04700624 Low Limit / Compressor Lockout Kit 1CG0419 Coil Guard (Electric / Electric & HP models) 8 25 lbs. - Johnson Controls Unitary Products 246645-YTG-C-0708 TABLE 1: ACCESSORIES (CONTINUED) Part Number Description Weight 1CG0420 Coil Guard (Gas / Electric models) - 1CG0427 Coil Guard (Electric / Electric & HP Models), 42" Tall Cabinet - 1CG0428 Coil Guard (Gas / Electric Models), 42" Tall Cabinet - 1HG0411 Hail Guard Kit - 1HG0415 Hail Guard Kit, 42" Tall Cabinet - 1GP0405 Gas Piping Kit - 1NP0442 Propane Conversion Kit - 1HA0442 High Altitude Kit for Natural Gas - 1HA0443 High Altitude Kit for Propane - 1FE0412 Flue Exhaust Extension Kit - 2BC04700106 Gas Heat Kit, -60 deg F, 230V - 2BC04700151 Gas Heat Kit, -60 deg F, 460V - 2BC04700154 Gas Heat Kit, -60 deg F, 575V - 1FL0402 Permanent Filter Kit (Includes (4) Four Filters) - 1FL0423 Permanent Filter Kit, (Includes (4) Four Filters) 42" Tall Cabinet - 2DF0401 Dirty Filter Switch - 1FF0410 Filter Frame Kit, Metal - 1FF0411 Metal Filter Frame Kit, 42" Tall Cabinet - Johnson Controls Unitary Products 9 246645-YTG-C-0708 NOMENCLATURE 6.5-12.5 Ton York® Model Number Nomenclature D M 090 N10 A 2 A AA 3 0 1 2 4 A Product Category Product Style D = A/C, Single Pkg., R-22 A = Style A B = Style B C = Style C Product Identifier Configuration Options (not required for all units) These four digits will not be assigned until a quote is requested, or an order placed. M = 9.0 EER A/C SS Drain Pan Nominal Cooling Capacity CPC Controller, DFS, APS 078 = 6.5 Ton 090 = 7.5 Ton 102 = 8.5 Ton 120 = 10.0 Ton 150 = 12.5 Ton Honeywell Controller, DFS, APS Johnson Controller UNT 1126 (N2 protocol), DFS, APS Novar Controller, DFS, APS Simplicity IntelliComfort Controller Simplicity IntelliComfort Controller w/ModLinc York Commercial Comfort System (YCCS) Rtu Controller 2" Pleated filters Heat Type and Nominal Heat Capacity BAS Ready Unit with Belimo Economizer Shipping Bag C00 = Cooling Only. No heat installed Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned Gas Heat Options Product Generation N10 = 100 MBH Output Aluminized Steel N15 = 150 MBH Output Aluminized Steel N20 = 200 MBH Output Aluminized Steel S10 = 100 MBH Output Stainless Steel S15 = 150 MBH Output Stainless Steel S20 = 200 MBH Output Stainless Steel 3 = Third Generation 4 = Fourth Generation Additional Options Electric Heat Options AA = None AB = Phase Monitor AC = Coil Guard AD = Dirty Filter Switch AE = Phase Monitor & Coil Guard AF = Phase Monitor & Dirty Filter Switch AG = Coil Guard & Dirty Filter Switch AH = Phase Monitor, Coil Guard & Dirty Filter Switch E09 = 9 KW E18 = 18 KW E24 = 24 KW E36 = 36 KW E54 = 54 KW RC = Coil Guard, Shipping Bag & American Flag TA = Technicoat Condenser Coil TJ = Technicoat Evaporator Coil TS = Technicoat Evaporator & Condenser Coils ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be located in digits 15-18. Airflow A = Std. Motor B = Std. Motor/Econo./Barometric Relief (Downflow Only) C = Std. Motor/Econo./Power Exhaust (Downflow Only) D = Std. Motor/Motorized Damper (Downflow Only) E = Std. Motor/Horizontal Economizer (No Baro.) F = Std. Motor/Slab Econo./Power Exhaust (Downflow Only) G = Std. Motor/Slab Econo./Barometric Relief (Downflow Only) N = Hi Static Mtr. P = Hi Static Mtr./Econo./Barometric Relief (Downflow Only) Q = Hi Static Mtr./Econo./Power Exhaust (Downflow Only) R = Hi Static Mtr./Motorized Damper (Downflow Only) S = Hi Static Mtr./Horizontal Economizer (No Baro.) T = Hi Static Mtr./Slab Econo./Power Exhaust (Downflow Only) U = Hi Static Mtr./Slab Econo./Barometric Relief (Downflow only) Voltage 2 = 208/230-3-60 3 = 380-3-60 4 = 460-3-60 5 = 575-3-60 Installation Options A = No Options Installed B = Option 1 C = Option 2 D = Options 1 & 2 E = Option 3 F = Option 4 G = Options 1 & 3 H = Options 1 & 4 J = Options 1, 2 & 3 K = Options 1, 2, & 4 L = Options 1,3 & 4 M = Options 1, 2, 3, & 4 N = Options 2 & 3 P = Options 2 & 4 Q = Options 2, 3, & 4 R = Options 3 & 4 S = Option 5 T = Options 1 & 5 U = Options 1, 3, & 5 V = Options 1, 4, & 5 W = Options 1, 3, 4, & 5 X = Options 3 & 5 Y = Options 4 & 5 Z = Options 3, 4 & 5 Options 1 = Disconnect 2 = Non-Pwr'd Conv. Outlet 3 = Smoke Detector S.A. 4 = Smoke Detector R.A. 5 = Pwr'd Conv. Outlet 10 Johnson Controls Unitary Products 246645-YTG-C-0708 TABLE 2: DM PHYSICAL DATA Models Component Evaporator Blower Evaporator Coil Condenser Fan (2 per Unit) Condenser Coil (2 per unit) Refrigerant Charge 078 090 102 120 150 Blower, Centrifugal (Dia. X Wd. in.) 15 x 15 12 x 12 12 X 12 15 x 15 15 x 15 Motor, Standard (HP) 1-1/2 2 3 2 3 Motor, Optional (HP) 2 3 3 3 5 Rows 2 2 3 2 3 Fins per Inch 15 15 15 15 15 Height (in.) 30 32 32 40 40 Face Area (ft.2 each) 9.9 10.67 10.67 13.2 13.2 Propeller Dia. (in., each) 24 24 24 24 24 Motor (HP, each) 1/3 3/4 3/4 3/4 3/4 CFM, Nominal (each) 1700 2200 2200 2200 2200 Rows (each) 1 1 1 1 2 Fins per Inch 20 20 20 20 20 Height (in. each) 24 28 36 44 44 Face Area (ft.2 each) 7.9 9.33 12 14.5 14.5 System 1 (lb./oz.) 4/6 4/10 5/8 6/12 10/12 System 2 (lb./oz.) 4/0 3/14 5/2 6/12 11/0 Quantity 2 2 2 2 2 Type Recip Recip Recip. Recip Scroll Size (Wd. x Ht. x Thickness in.) 25x20x2 25x16x2 25x16x2 25x20x2 25x20x2 Number Per Unit 4 4 4 4 4 Compressors Air Filters Johnson Controls Unitary Products 11 246645-YTG-C-0708 TABLE 3: DM CAPACITY RATINGS Cooling Capacities ARI Ratings* Size (Tons) CFM Model MBH EER IPLV Gas Heat Capacity Nominal Sound Gas Line Electric Heat Rating Size ‡ Seasonal Temp. Capacity Input Output (in. OD) (dB)† Efficiency Rise (kW) (MBH) (MBH) (%) (°F) Cooling Only 078 (6-1/2) 090 (7-1/2) 102 (8-1/2) Electric Heat 150 (12-1/2) 9.0 9.45 2600 84 - - - - - 9, 18, 24, 34 - - - - - Gas Heat - 120 96 80 20-50 3/4 Gas Heat - 180 144 80 35-65 3/4 Cooling Only - - - - - - 18, 34 - - - - - Electric Heat 86 9.0 9.2 2886 89 Gas Heat - 120 96 80 15-45 3/4 Gas Heat - 180 144 80 30-60 3/4 Cooling Only - - - - - - 9, 18, 24, 34 - - - - - Gas Heat - 120 96 80 15-45 3/4 Gas Heat - 180 144 80 30-60 3/4 Cooling Only - - - - - - 9, 24, 34 54 - - - - - Gas Heat - 180 144 80 20-50 3/4 Gas Heat - 240 192 80 35-65 3/4 Cooling Only - - - - - - 9, 24, 34, 54 - - - - - Gas Heat - 180 144 80 10-40 3/4 Gas Heat - 240 192 80 25-55 3/4 Electric Heat Electric Heat 120 (10) 77 - Electric Heat 99 120 144 9.0 9.0 9.3 10.04 9.10 9.25 3400 90 4000 90 4500 90 * Rated at 95°F ambient 80°F dry bulb and 67°F wet bulb. † Rated in accordance with ARI 270 standard. ‡ See Table 20. TABLE 4: UNIT VOLTAGE LIMITATIONS 12 POWER RATING MIN. MAX. 208/230-3-60 187 252 460-3-60 432 504 575-3-60 540 630 Johnson Controls Unitary Products 246645-YTG-C-0708 TABLE 5: COOLING CAPACITY DM078 (6-1/2 TON) UNIT Air On Evap. Coil CFM 1950 2275 2600 2925 3250 1950 2275 2600 2925 3250 1950 2275 2600 2925 3250 WB (°F) Temperature of Air on Condenser Coil 85°F Tot. Tot. Cap.* (MBH) Input† (kW) 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 87 80 71 66 91 83 74 69 94 87 77 72 95 88 77 73 96 89 78 74 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 73 66 64 54 76 68 67 56 78 71 69 58 78 70 69 58 78 70 69 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 62 51 67 42 63 52 68 43 63 52 69 43 64 53 70 44 65 54 71 44 Temperature of Air on Condenser Coil 95°F Sensible Capacity (MBH)* Return Dry Bulb (°F) Tot. Tot. Input† (kW) 71 68 Cap.* (MBH) 6.8 49 43 37 32 26 6.7 61 55 50 44 38 33 6.4 71 66 61 55 50 44 6.4 66 66 61 56 50 44 6.9 54 47 41 34 28 6.7 67 61 54 47 41 34 6.5 74 72 66 60 53 47 6.5 69 69 67 60 54 47 7.0 59 52 44 37 29 6.8 74 66 58 51 43 36 6.6 77 77 72 64 57 49 6.6 72 72 72 65 57 49 7.0 63 55 46 37 29 6.8 78 70 61 52 44 35 6.6 77 77 75 66 58 49 6.6 73 73 73 64 56 47 7.0 67 58 48 38 29 6.8 83 73 64 54 44 35 6.6 78 78 78 68 59 49 6.6 74 74 74 64 54 45 Temperature of Air on Condenser Coil 105°F 7.8 43 37 31 26 20 7.5 54 48 43 37 32 26 7.4 61 57 52 46 41 35 7.3 54 54 48 43 37 32 7.9 48 41 34 28 21 7.6 60 54 47 40 34 27 7.5 65 62 57 50 44 37 7.4 56 56 53 46 40 33 8.0 53 45 38 30 22 7.7 66 59 51 44 36 28 7.5 69 67 62 54 47 39 7.5 58 58 58 50 42 35 8.0 57 48 40 31 23 7.7 68 62 54 46 37 28 7.6 69 68 64 56 47 38 7.5 58 58 58 49 40 32 8.1 61 52 42 32 23 7.8 70 66 57 48 38 28 7.6 69 69 67 57 48 38 7.6 57 57 57 48 38 28 Temperature of Air on Condenser Coil 125°F 8.8 38 32 27 21 15 8.4 48 42 37 31 25 20 8.4 57 50 44 39 33 27 8.3 42 42 37 31 26 20 8.8 42 35 29 22 16 8.4 52 46 40 33 27 20 8.5 63 56 48 41 35 28 8.3 43 43 40 33 27 20 8.9 46 39 31 23 16 8.5 52 50 43 35 28 20 8.5 69 62 52 44 37 29 8.4 43 43 43 35 28 20 9.0 52 43 34 26 17 8.6 53 53 47 39 30 21 8.6 70 66 58 50 41 32 8.5 44 44 44 35 26 18 9.1 57 47 38 28 18 8.7 54 54 52 42 32 23 8.8 71 71 65 55 45 36 8.6 44 44 44 34 25 15 27 39 39 28 40 40 28 42 42 26 40 38 25 39 35 78 73 63 59 82 76 66 62 86 80 69 65 85 79 69 64 85 78 68 64 21 30 26 21 31 27 21 31 27 20 30 23 19 28 19 67 58 66 48 69 60 67 49 71 61 69 50 71 62 69 51 71 62 70 51 86 Johnson Controls Unitary Products 83 80 77 74 14 22 15 13 22 14 12 21 13 13 24 9 13 26 5 Sensible Capacity (MBH)* Return Dry Bulb (°F) 71 68 7.3 45 40 34 28 23 7.1 57 52 46 41 35 29 6.9 63 61 56 50 45 39 6.8 59 59 54 49 43 37 7.4 50 44 37 31 24 7.2 64 57 51 44 38 31 6.9 66 65 61 55 48 42 6.9 62 62 60 53 46 40 7.5 56 48 41 33 26 7.3 70 63 55 48 40 33 7.0 69 69 67 59 52 44 7.0 65 65 65 57 50 42 7.5 60 51 43 34 25 7.3 74 66 58 49 40 32 7.1 69 69 67 59 50 42 7.0 64 64 64 56 47 39 7.5 64 54 44 35 25 7.3 78 70 60 50 41 31 7.1 68 68 68 58 49 39 7.1 64 64 64 54 45 35 Temperature of Air on Condenser Coil 115°F 8.3 40 35 29 23 18 7.9 51 45 40 34 29 23 7.9 59 54 48 42 37 31 7.8 48 48 43 37 31 26 8.4 45 38 32 25 18 8.0 56 50 43 37 30 24 8.0 64 59 52 46 39 33 7.9 49 49 46 40 33 27 8.4 49 42 34 27 19 8.1 61 55 47 39 32 24 8.0 69 64 57 49 42 34 7.9 50 50 50 43 35 28 8.5 54 46 37 28 20 8.2 62 58 51 42 33 25 8.1 69 67 61 53 44 35 8.0 51 51 51 42 33 25 8.6 59 49 40 30 20 8.3 62 62 55 45 35 25 8.2 70 70 66 56 46 37 8.1 51 51 51 41 31 22 86 83 80 77 74 24 33 32 24 35 33 25 37 35 23 33 30 21 29 25 17 26 20 17 26 20 17 26 20 16 27 16 16 27 12 * These capacities are gross ratings. For net capacity, deduct air blower motor, MBH = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. † These ratings include condenser fan motors and the compressor motors but not the supply air blower motor. 13 246645-YTG-C-0708 TABLE 6: COOLING CAPACITY DM090 (7-1/2 TON) UNIT Temperature of Air on Condenser Coil Air on Evaporator Coil CFM 2250 2625 3000 3375 3750 2250 2625 3000 3375 3750 2250 2625 3000 3375 3750 * † 14 75°F 85°F Sensible Capacity (MBH)* Return Dry Bulb (°F) WB (°F) Total Cap.* (MBH) Total† Input (kW) 86 83 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 101.7 96.3 89.4 88.6 105.2 99.6 92.5 91.6 108.7 102.9 95.6 94.7 110.1 104.2 96.8 95.9 111.5 105.5 98.0 97.1 7.2 7.1 7.0 6.9 7.3 7.2 7.0 7.0 7.3 7.2 7.1 7.0 7.3 7.2 7.1 7.1 7.4 7.2 7.1 7.1 57.5 73.3 89.4 88.6 63.7 80.9 92.5 91.6 70.0 88.5 95.6 94.7 74.1 93.8 96.8 95.9 78.3 99.1 98.0 97.1 51.1 66.8 80.1 85.9 56.2 73.3 87.8 90.3 61.2 79.7 95.6 94.7 64.1 83.3 96.8 95.9 67.1 86.8 98.0 97.1 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 91.8 85.3 77.5 78.9 94.6 87.9 79.9 81.3 97.5 90.6 82.3 83.8 98.7 91.7 83.3 84.8 99.9 92.8 84.4 85.9 8.4 8.2 8.0 8.0 8.4 8.3 8.1 8.1 8.5 8.3 8.1 8.2 8.5 8.4 8.2 8.2 8.5 8.4 8.2 8.2 54.1 68.4 77.5 78.9 59.9 75.4 79.9 81.3 65.7 82.4 82.3 83.8 70.6 87.6 83.3 84.8 75.5 92.8 84.4 85.9 47.7 62.0 74.6 77.8 52.3 67.8 78.5 80.8 56.9 73.6 82.3 83.8 60.6 78.2 83.3 84.8 64.3 82.7 84.4 85.9 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 79.5 70.7 67.3 67.6 81.2 72.2 68.7 69.0 82.9 73.7 70.1 70.4 84.3 74.9 71.3 71.6 85.7 76.1 72.5 72.8 9.6 9.3 9.1 9.1 9.6 9.4 9.2 9.2 9.7 9.5 9.3 9.3 9.8 9.5 9.3 9.3 9.8 9.5 9.4 9.4 49.1 62.5 67.3 67.6 54.4 68.1 68.7 69.0 59.8 73.7 70.1 70.4 64.8 74.9 71.3 71.6 69.9 76.1 72.5 72.8 42.6 56.0 66.3 65.6 46.8 61.3 68.2 68.0 51.0 66.6 70.1 70.4 54.9 71.4 71.3 71.6 58.7 76.1 72.5 72.8 80 44.7 60.4 73.7 79.5 48.6 65.7 80.1 86.5 52.5 71.0 86.6 93.4 54.2 73.3 91.1 95.2 55.9 75.6 95.7 97.1 95°F 41.3 55.6 68.2 71.4 44.7 60.2 73.9 77.4 48.2 64.9 79.6 83.3 50.7 68.2 82.0 84.6 53.1 71.6 84.4 85.9 115°F 36.2 49.6 59.9 59.2 39.2 53.8 64.8 64.1 42.3 57.9 69.8 69.1 44.9 61.5 71.2 70.9 47.5 65.1 72.5 72.8 Sensible Capacity (MBH)* Return Dry Bulb (°F) Total† Total Cap.* Input (MBH) (kW) 77 74 71 68 86 83 38.3 54.0 67.3 73.1 41.0 58.1 72.5 78.9 43.7 62.2 77.8 84.6 44.2 63.3 81.2 85.3 44.7 64.4 84.5 85.9 31.8 47.6 60.9 66.7 33.4 50.5 65.0 71.3 35.0 53.5 69.1 75.9 34.3 53.4 71.2 75.3 33.5 53.3 73.3 74.7 41.2 54.4 60.3 43.0 57.4 63.7 44.7 60.3 67.2 43.4 61.2 65.4 42.1 62.1 63.6 34.8 48.0 53.8 35.4 49.8 56.1 36.0 51.6 58.4 33.5 51.3 55.4 30.9 51.0 52.4 96.7 90.8 83.5 83.7 99.9 93.8 86.2 86.5 103.1 96.8 89.0 89.2 104.4 98.0 90.1 90.4 105.7 99.2 91.2 91.5 7.8 7.6 7.5 7.5 7.8 7.7 7.5 7.5 7.9 7.8 7.6 7.6 7.9 7.8 7.6 7.6 7.9 7.8 7.6 7.6 55.8 70.8 83.5 83.7 61.8 78.1 86.2 86.5 67.8 85.4 89.0 89.2 72.3 90.7 90.1 90.4 76.9 96.0 91.2 91.5 49.4 64.4 77.4 81.9 54.2 70.6 83.2 85.6 59.1 76.7 89.0 89.2 62.4 80.7 90.1 90.4 65.7 84.8 91.2 91.5 34.9 49.2 61.8 65.0 37.1 52.7 66.3 69.8 39.4 56.1 70.9 74.6 40.7 58.3 72.0 74.6 42.0 60.4 73.2 74.7 28.4 42.8 55.4 58.6 29.6 45.1 58.8 62.2 30.7 47.4 62.1 65.8 30.7 48.3 62.1 64.7 30.8 49.2 62.0 63.5 36.3 49.0 52.1 37.5 51.2 54.6 38.6 53.4 57.1 38.3 52.1 54.7 38.0 50.8 52.3 29.9 42.6 45.7 29.9 43.6 47.0 29.9 44.6 48.3 28.4 42.1 44.7 26.9 39.6 41.1 85.6 78.0 72.4 73.2 87.9 80.1 74.3 75.2 90.2 82.1 76.2 77.1 91.5 83.3 77.3 78.2 92.8 84.5 78.4 79.3 9.0 8.7 8.6 8.6 9.0 8.8 8.6 8.7 9.1 8.9 8.7 8.7 9.1 8.9 8.8 8.8 9.2 8.9 8.8 8.8 51.6 65.4 72.4 73.2 57.1 71.7 74.3 75.2 62.7 78.0 76.2 77.1 67.7 81.2 77.3 78.2 72.7 84.5 78.4 79.3 45.2 59.0 70.5 71.7 49.6 64.6 73.3 74.4 54.0 70.1 76.2 77.1 57.7 74.8 77.3 78.2 61.5 79.4 78.4 79.3 29.8 43.2 53.4 52.8 31.7 46.2 57.3 56.6 33.5 49.1 61.1 60.3 34.9 51.5 61.2 61.0 36.3 53.9 61.3 61.6 23.4 36.8 47.0 46.4 24.1 38.6 49.7 49.0 24.8 40.4 52.3 51.6 25.0 41.6 51.2 51.0 25.2 42.7 50.1 50.4 30.4 40.6 40.0 31.0 42.1 41.4 31.6 43.6 42.8 31.6 41.3 41.0 31.6 38.9 39.3 24.0 34.2 33.5 23.4 34.5 33.8 22.9 34.8 34.1 21.6 31.3 31.1 20.4 27.8 28.1 73.4 63.4 62.2 61.9 74.5 64.3 63.1 62.8 75.5 65.2 64.0 63.7 77.0 66.5 65.3 65.0 78.6 67.8 66.5 66.2 10.1 9.8 9.7 9.7 10.2 9.9 9.8 9.8 10.3 10.0 9.9 9.9 10.4 10.0 9.9 9.9 10.4 10.1 10.0 9.9 46.5 59.5 62.2 61.9 51.7 64.3 63.1 62.8 56.8 65.2 64.0 63.7 61.9 66.5 65.3 65.0 67.1 67.8 66.5 66.2 40.1 53.1 62.1 59.5 44.1 58.1 63.0 61.6 48.1 63.2 64.0 63.7 52.0 66.5 65.3 65.0 55.9 67.8 66.5 66.2 80 43.0 58.0 71.0 75.5 46.6 63.0 77.0 81.9 50.3 67.9 83.1 88.4 52.4 70.8 86.6 89.9 54.5 73.6 90.0 91.5 105°F 38.8 52.6 64.0 65.3 42.0 57.0 69.4 70.7 45.2 61.4 74.7 76.2 47.8 64.9 76.6 77.8 50.3 68.3 78.4 79.3 125°F 33.7 46.6 55.7 53.1 36.5 50.5 60.3 57.5 39.3 54.4 64.0 62.0 42.0 58.1 65.3 64.1 44.7 61.9 66.5 66.2 77 74 71 68 36.6 51.6 64.5 69.0 39.1 55.4 69.4 74.3 41.6 59.2 74.3 79.6 42.5 60.8 76.6 80.0 43.3 62.4 78.8 80.3 30.1 45.2 58.1 62.6 31.5 47.8 61.9 66.7 32.8 50.4 65.6 70.9 32.5 50.8 66.6 70.0 32.2 51.2 67.7 69.1 38.8 51.7 56.2 40.2 54.3 59.2 41.7 56.8 62.1 40.9 56.7 60.0 40.1 56.5 57.9 32.4 45.3 49.8 32.6 46.7 51.6 32.9 48.1 53.4 30.9 46.7 50.1 28.9 45.3 46.8 32.3 46.2 57.6 58.9 34.4 49.4 61.8 63.2 36.5 52.6 66.0 67.4 37.8 54.9 66.6 67.8 39.2 57.2 67.2 68.1 25.9 39.8 51.2 52.5 26.8 41.8 54.2 55.6 27.7 43.9 57.2 58.7 27.8 44.9 56.6 57.8 28.0 46.0 56.1 57.0 33.4 44.8 46.1 34.3 46.6 48.0 35.1 48.5 49.9 35.0 46.7 47.9 34.8 44.9 45.8 26.9 38.4 39.6 26.7 39.1 40.4 26.4 39.7 41.2 25.0 36.7 37.9 23.6 33.7 34.6 27.3 40.2 49.2 46.7 28.9 42.9 52.7 49.9 30.6 45.7 56.2 53.2 32.1 48.2 55.8 54.1 33.5 50.7 55.4 55.1 20.9 33.8 42.8 40.3 21.3 35.4 45.1 42.4 21.8 36.9 47.4 44.5 22.1 38.2 45.8 44.2 22.4 39.5 44.2 43.9 27.4 36.4 33.9 27.8 37.6 34.8 28.2 38.7 35.7 28.2 35.8 34.2 28.3 33.0 32.7 21.0 30.0 27.4 20.2 30.0 27.2 19.4 29.9 27.0 18.3 25.9 24.2 17.2 21.8 21.5 The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH=3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 246645-YTG-C-0708 TABLE 7: COOLING CAPACITY DM102 (8-1/2 TON) UNIT Temperature of Air on Condenser Coil Air on Evaporator Coil CFM 2550 2975 3400 3825 4250 2550 2975 3400 3825 4250 2550 2975 3400 3825 4250 * † 75°F 85°F Sensible Capacity (MBH)* Return Dry Bulb (°F) WB (°F) Total Cap.* (MBH) Total† Input (kW) 86 83 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 123.8 112.4 106.9 99.3 127.6 115.9 110.3 102.4 131.5 119.4 113.7 105.5 134.7 122.3 116.4 108.1 137.9 125.3 119.2 110.7 7.4 7.3 7.1 7.1 7.4 7.3 7.2 7.1 7.5 7.4 7.2 7.2 7.5 7.4 7.3 7.3 7.6 7.5 7.3 7.3 68.9 85.2 106.9 99.3 75.6 93.2 110.3 102.4 82.4 101.2 113.7 105.5 88.7 110.0 116.4 108.1 95.1 118.8 119.2 110.7 61.6 78.0 95.5 98.9 67.0 84.6 104.6 102.2 72.5 91.3 113.7 105.5 77.5 97.3 116.4 108.1 82.4 103.4 119.2 110.7 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 105.8 96.1 86.0 87.0 109.7 99.7 89.1 90.2 113.6 103.2 92.3 93.5 115.7 105.1 94.0 95.2 117.7 107.0 95.7 96.9 8.7 8.5 8.3 8.3 8.8 8.5 8.3 8.4 8.8 8.6 8.4 8.4 8.9 8.6 8.4 8.5 8.9 8.7 8.5 8.5 61.7 78.5 86.0 87.0 68.3 86.6 89.1 90.2 74.9 94.6 92.3 93.5 81.2 100.8 94.0 95.2 87.6 107.0 95.7 96.9 54.5 71.3 86.0 87.0 59.7 78.0 89.1 90.2 65.0 84.7 92.3 93.5 70.0 90.9 94.0 95.2 74.9 97.1 95.7 96.9 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 88.0 77.2 72.9 72.1 91.2 80.0 75.5 74.7 94.5 82.8 78.2 77.4 95.6 83.9 79.2 78.3 96.8 84.9 80.2 79.3 10.0 9.7 9.6 9.6 10.1 9.7 9.6 9.6 10.1 9.8 9.7 9.7 10.2 9.8 9.7 9.7 10.2 9.9 9.8 9.8 54.3 70.0 72.9 72.1 60.8 76.4 75.5 74.7 67.2 82.8 78.2 77.4 73.5 83.9 79.2 78.3 79.8 84.9 80.2 79.3 47.1 62.8 71.8 71.9 52.2 69.4 75.0 74.6 57.3 76.0 78.2 77.4 62.2 80.4 79.2 78.3 67.1 84.9 80.2 79.3 80 77 54.3 47.1 70.7 63.4 88.1 80.8 91.5 84.2 58.5 49.9 76.0 67.4 94.7 86.1 98.4 89.8 62.6 52.6 81.3 71.4 101.4 91.5 105.3 95.4 66.2 54.9 86.0 74.7 110.3 99.0 108.0 96.7 69.8 57.1 90.7 78.0 119.2 106.5 110.7 98.0 95°F 47.2 39.9 64.0 56.7 78.8 71.6 79.9 72.6 51.1 42.5 69.4 60.8 85.4 76.8 86.6 78.0 55.1 45.2 74.7 64.8 92.1 82.1 93.3 83.4 58.7 47.4 79.6 68.3 93.9 82.6 95.1 83.8 62.2 49.6 84.4 71.8 95.7 83.0 96.9 84.2 115°F 39.8 32.5 55.5 48.2 64.5 57.3 64.6 57.3 43.6 35.0 60.8 52.2 70.7 62.1 70.8 62.2 47.4 37.5 66.1 56.2 76.9 67.0 77.0 67.1 50.9 39.6 71.0 59.7 78.5 67.2 78.1 66.8 54.4 41.8 75.9 63.2 80.2 67.5 79.3 66.6 Sensible Capacity (MBH)* Return Dry Bulb (°F) Total† Total Cap.* Input (MBH) (kW) 74 71 68 86 83 80 77 74 71 68 39.8 56.2 73.5 76.9 41.3 58.8 77.5 81.2 42.7 61.5 81.5 85.5 43.6 63.4 87.7 85.4 44.4 65.4 93.8 85.3 48.9 66.3 69.7 50.2 69.0 72.6 51.6 71.6 75.5 52.1 76.4 74.1 52.7 81.2 72.6 41.6 59.0 62.4 41.7 60.4 64.0 41.7 61.7 65.6 40.9 65.1 62.8 40.0 68.5 60.0 114.8 104.3 96.4 93.2 118.7 107.8 99.7 96.3 122.6 111.3 103.0 99.5 125.2 113.7 105.2 101.6 127.8 116.1 107.4 103.8 8.0 7.9 7.7 7.7 8.1 7.9 7.7 7.8 8.2 8.0 7.8 7.8 8.2 8.0 7.8 7.9 8.3 8.1 7.9 7.9 65.3 81.9 96.4 93.2 72.0 89.9 99.7 96.3 78.7 97.9 103.0 99.5 85.0 105.4 105.2 101.6 91.3 112.9 107.4 103.8 58.0 74.6 90.7 92.9 63.4 81.3 96.9 96.2 68.7 88.0 103.0 99.5 73.7 94.1 105.2 101.6 78.7 100.2 107.4 103.8 43.5 60.1 76.2 78.4 46.2 64.1 81.5 83.9 48.9 68.1 86.8 89.4 51.1 71.5 90.8 90.2 53.3 74.9 94.8 91.1 36.2 52.8 68.9 71.1 37.6 55.5 72.9 75.3 39.0 58.2 76.9 79.5 39.8 60.2 79.5 78.9 40.7 62.2 82.1 78.4 45.5 61.6 63.9 46.9 64.3 66.7 48.3 67.0 69.5 48.9 68.2 67.6 49.6 69.4 65.8 38.3 54.4 56.6 38.3 55.7 58.1 38.4 57.1 59.6 37.6 56.9 56.4 36.9 56.8 53.1 32.6 49.5 64.3 65.3 34.0 52.2 68.3 69.4 35.3 54.9 72.2 73.5 36.1 57.0 71.3 72.5 36.9 59.1 70.4 71.5 42.2 57.0 58.1 43.6 59.7 60.8 45.0 62.3 63.5 45.7 60.0 61.2 46.4 57.7 58.9 34.9 49.7 50.8 35.0 51.1 52.2 35.1 52.4 53.6 34.4 48.7 49.9 33.7 45.0 46.2 96.9 86.6 79.4 79.5 100.5 89.8 82.3 82.5 104.0 93.0 85.3 85.4 105.6 94.5 86.6 86.7 107.3 95.9 87.9 88.1 9.4 9.1 8.9 8.9 9.4 9.1 9.0 9.0 9.5 9.2 9.0 9.1 9.5 9.2 9.1 9.1 9.6 9.3 9.1 9.1 58.0 74.3 79.4 79.5 64.6 81.5 82.3 82.5 71.1 88.7 85.3 85.4 77.4 92.3 86.6 86.7 83.7 95.9 87.9 88.1 50.8 67.0 78.9 79.4 56.0 73.7 82.1 82.4 61.2 80.3 85.3 85.4 66.1 85.7 86.6 86.7 71.0 91.0 87.9 88.1 36.2 52.5 64.4 65.0 38.8 56.5 69.5 70.1 41.3 60.5 74.6 75.2 43.5 64.0 74.9 75.3 45.7 67.5 75.3 75.4 29.0 45.2 57.1 57.7 30.2 47.9 60.9 61.5 31.4 50.6 64.6 65.3 32.2 52.7 63.6 64.0 33.0 54.8 62.6 62.7 37.9 49.9 50.4 39.3 52.3 52.9 40.7 54.7 55.4 41.4 52.3 52.7 42.1 49.9 50.1 30.7 42.6 43.2 30.7 43.7 44.3 30.8 44.8 45.5 30.1 41.0 41.4 29.5 37.3 37.4 25.3 40.9 50.0 50.1 26.4 43.6 53.5 53.6 27.6 46.3 57.1 57.1 28.3 48.4 55.9 55.5 29.1 50.5 54.8 53.9 33.7 42.7 42.8 35.0 44.9 45.0 36.4 47.1 47.2 37.1 44.6 44.3 37.9 42.1 41.3 26.4 35.5 35.5 26.4 36.3 36.4 26.4 37.2 37.3 25.8 33.4 33.0 25.2 29.5 28.6 79.1 67.7 66.3 64.6 82.0 70.2 68.7 67.0 84.9 72.6 71.2 69.3 85.6 73.2 71.8 69.9 86.3 73.8 72.4 70.5 10.7 10.2 10.2 10.2 10.7 10.3 10.2 10.2 10.8 10.4 10.3 10.3 10.9 10.4 10.4 10.4 10.9 10.5 10.4 10.4 50.7 65.8 66.3 64.6 57.0 70.2 68.7 67.0 63.4 72.6 71.2 69.3 69.6 73.2 71.8 69.9 75.9 73.8 72.4 70.5 43.4 58.5 64.7 64.3 48.4 65.1 68.0 66.8 53.5 71.7 71.2 69.3 58.3 73.2 71.8 69.9 63.2 73.8 72.4 70.5 50.8 67.3 83.5 85.7 54.8 72.7 90.1 92.5 58.8 78.0 96.7 99.3 62.4 82.8 102.1 101.5 66.0 87.6 107.4 103.8 105°F 43.5 59.7 71.7 72.2 47.4 65.1 78.1 78.7 51.3 70.4 84.5 85.1 54.8 75.3 86.2 86.6 58.3 80.2 87.9 88.1 125°F 36.1 51.2 57.4 57.0 39.8 56.5 63.4 62.9 43.6 61.8 69.3 68.8 47.1 66.7 70.8 69.7 50.5 71.6 72.4 70.5 28.8 44.0 50.1 49.7 31.3 47.9 54.8 54.3 33.7 51.9 59.4 58.9 35.8 55.4 59.6 58.4 37.9 58.9 59.7 57.8 21.6 36.7 42.9 42.4 22.7 39.3 46.2 45.7 23.7 41.9 49.5 49.0 24.5 44.1 48.3 47.1 25.2 46.3 47.0 45.1 29.4 35.6 35.2 30.7 37.6 37.1 32.0 39.6 39.1 32.8 37.0 35.8 33.6 34.4 32.5 22.1 28.3 27.9 22.1 29.0 28.5 22.1 29.6 29.2 21.5 25.7 24.5 20.9 21.7 19.8 The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH=3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 15 246645-YTG-C-0708 TABLE 8: COOLING CAPACITY DM120 (10 TON) UNIT Air On Evap. Coil CFM 3000 3500 4000 4500 5000 3000 3500 4000 4500 5000 3000 3500 4000 4500 5000 16 WB (°F) Temperature of Air on Condenser Coil 85°F Tot. Tot. Cap.* (MBH) Input† (kW) 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 132 124 116 110 135 127 119 112 138 130 121 115 141 132 124 117 144 135 126 119 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 117 107 97 98 121 110 100 102 124 113 103 105 127 116 106 107 130 119 108 110 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 101 87 79 83 105 90 81 86 108 92 84 88 112 96 87 91 115 99 89 94 Temperature of Air on Condenser Coil 95°F Sensible Capacity (MBH)* Return Dry Bulb (°F) Tot. Tot. Input† (kW) 71 68 Cap.* (MBH) 11.0 76 68 59 50 42 10.7 96 87 79 70 62 53 10.5 115 106 98 89 81 72 10.3 110 109 101 92 83 75 11.1 83 73 63 53 43 10.8 104 94 84 74 64 54 10.6 118 114 105 95 84 74 10.4 112 112 108 98 87 77 11.2 91 79 67 56 44 10.9 113 101 90 78 66 55 10.7 121 121 111 100 88 76 10.5 115 115 115 103 91 80 11.3 98 85 71 58 45 11.0 122 108 95 82 69 55 10.7 124 124 118 105 92 78 10.5 117 117 117 104 90 77 11.3 105 90 75 60 45 11.0 130 116 101 86 71 56 10.8 126 126 125 110 95 80 10.6 119 119 119 105 90 75 Temperature of Air on Condenser Coil 105°F 12.4 70 62 53 45 36 12.0 89 80 71 63 54 46 11.6 97 94 85 77 68 60 11.7 98 96 88 79 71 62 12.5 78 68 58 48 38 12.1 98 88 78 68 57 47 11.7 100 99 93 83 73 62 11.8 102 100 95 85 75 65 12.7 86 74 63 51 39 12.2 107 96 84 72 61 49 11.9 103 103 100 89 77 65 11.9 105 105 103 91 80 68 12.8 93 79 66 53 39 12.3 112 102 88 75 62 49 12.0 106 106 104 91 77 64 12.0 107 107 106 93 80 66 12.9 99 84 69 54 40 12.4 117 108 93 78 63 48 12.1 108 108 107 93 78 63 12.1 110 110 110 95 80 65 Temperature of Air on Condenser Coil 125°F 13.8 64 55 46 38 29 13.0 80 72 63 55 46 38 12.7 79 79 74 65 57 48 12.9 83 82 74 65 56 48 14.0 71 61 51 40 30 13.2 89 79 69 59 49 39 12.9 81 81 80 70 60 50 13.0 86 85 80 70 60 50 14.1 78 66 55 43 31 13.3 92 86 75 63 51 40 13.0 84 84 84 75 64 52 13.1 88 88 87 75 63 52 14.2 86 72 59 46 32 13.4 96 94 80 67 54 41 13.1 87 87 87 75 62 49 13.2 91 91 90 77 64 51 14.4 93 78 63 48 33 13.6 99 99 86 71 56 41 13.3 89 89 89 75 60 45 13.4 94 94 94 79 65 50 45 64 66 44 64 67 43 65 68 42 65 64 41 65 60 125 116 106 106 129 120 110 109 133 124 113 113 135 126 115 115 138 128 117 117 37 51 54 37 52 55 37 54 56 35 51 53 33 48 50 109 97 88 91 113 100 91 94 116 103 94 97 119 106 96 99 123 109 99 102 86 83 80 77 74 29 40 39 29 40 40 28 40 40 27 35 37 27 30 35 Sensible Capacity (MBH)* Return Dry Bulb (°F) 71 68 11.7 74 65 57 48 40 11.4 93 84 75 67 58 50 11.1 106 100 91 82 74 65 11.1 106 103 95 86 78 69 11.8 82 72 62 52 41 11.5 102 92 82 72 62 52 11.2 110 106 99 89 79 69 11.2 109 108 103 93 83 73 12.0 90 78 67 55 43 11.7 112 100 89 77 65 54 11.3 113 113 107 95 84 72 11.3 113 113 111 100 88 76 12.0 96 83 70 56 43 11.7 119 106 92 79 66 53 11.4 115 115 112 98 85 72 11.4 115 115 114 101 88 74 12.1 102 87 72 58 43 11.8 126 111 96 81 67 52 11.5 117 117 116 101 86 71 11.5 117 117 117 102 87 72 Temperature of Air on Condenser Coil 115°F 13.1 67 58 50 41 33 12.5 85 76 67 59 50 42 12.2 88 88 80 71 62 54 12.3 91 89 81 72 64 55 13.2 75 64 54 44 34 12.6 94 83 73 63 53 43 12.3 91 91 87 76 66 56 12.4 94 93 88 78 67 57 13.4 82 70 59 47 35 12.8 103 91 79 68 56 44 12.4 94 94 94 82 70 59 12.5 97 97 95 83 71 60 13.5 89 76 63 49 36 12.9 106 98 84 71 58 45 12.5 96 96 96 83 70 56 12.6 99 99 98 85 72 59 13.6 96 81 66 51 37 13.0 109 104 90 75 60 45 12.7 99 99 99 84 69 54 12.7 102 102 102 87 72 57 86 83 80 77 74 41 57 61 42 58 63 42 60 65 39 58 61 37 57 57 33 45 46 33 46 47 33 47 48 31 43 45 30 39 42 * These capacities are gross ratings. For net capacity, deduct air blower motor, MBH = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. † These ratings include condenser fan motors and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 246645-YTG-C-0708 TABLE 9: COOLING CAPACITY DM150 (12-1/2 TON) UNIT Air On Evap. Coil CFM 3750 4375 5000 5625 6250 3750 4375 5000 5625 6250 3750 4375 5000 5625 6250 WB (°F) Temperature of Air on Condenser Coil 85°F Tot. Tot. Cap.* (MBH) Input† (kW) 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 154 152 145 144 158 156 148 147 161 159 151 150 161 158 151 150 160 158 150 149 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 144 139 130 130 148 143 134 134 152 147 137 137 151 145 136 136 149 144 134 135 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 131 124 114 114 136 128 117 118 140 132 121 121 137 129 119 119 134 127 117 117 Temperature of Air on Condenser Coil 95°F Sensible Capacity (MBH)* Return Dry Bulb (°F) Tot. Tot. Input† (kW) 71 68 Cap.* (MBH) 12.0 93 82 71 61 50 39 11.8 122 112 101 90 79 69 11.6 145 138 128 117 106 96 11.6 144 143 133 122 111 101 12.0 101 89 76 63 51 38 11.8 133 120 107 95 82 70 11.7 148 145 136 123 111 98 11.7 147 147 141 129 116 104 12.1 110 95 81 66 52 37 11.8 143 129 114 99 85 70 11.7 151 151 144 130 115 101 11.7 150 150 150 136 121 106 12.1 116 99 83 66 49 33 11.9 150 133 117 100 83 67 11.7 151 151 147 131 114 97 11.7 150 150 150 133 116 100 12.1 122 103 84 66 47 28 11.9 156 138 119 100 82 63 11.7 150 150 150 132 113 94 11.7 149 149 149 130 112 93 Temperature of Air on Condenser Coil 105°F 15.1 88 77 66 56 45 34 14.7 117 106 96 85 74 63 14.5 130 126 115 104 94 83 14.5 130 128 117 106 96 85 15.1 98 85 72 60 47 34 14.8 129 117 104 91 79 66 14.6 134 131 125 113 100 87 14.6 134 132 127 114 102 89 15.2 107 93 78 63 49 34 14.9 141 127 112 98 83 68 14.6 137 137 135 121 106 91 14.7 137 137 137 123 108 93 15.3 113 96 80 63 47 30 14.9 142 131 115 98 82 65 14.7 136 136 135 118 102 85 14.7 136 136 136 119 103 86 15.3 119 100 82 63 44 26 14.9 144 136 117 99 80 61 14.7 134 134 134 116 97 79 14.7 135 135 135 116 97 79 Temperature of Air on Condenser Coil 125°F 18.3 81 71 60 49 39 28 17.8 111 100 90 79 68 58 17.5 114 110 100 89 78 68 17.6 114 109 98 87 77 66 18.4 92 80 67 54 42 29 18.0 124 113 100 88 75 62 17.6 117 116 112 99 86 74 17.8 118 115 110 97 85 72 18.6 103 89 74 60 45 30 18.2 132 125 111 96 81 67 17.8 121 121 121 109 94 80 18.0 121 121 121 107 92 78 18.7 108 92 75 58 42 25 18.2 129 129 112 95 79 62 17.9 119 119 119 103 87 70 18.0 119 119 119 102 86 69 18.8 113 95 76 57 39 20 18.3 127 127 113 95 76 58 18.0 117 117 117 98 79 61 18.1 117 117 117 98 79 61 29 58 85 90 26 57 85 91 22 56 86 92 16 50 81 83 10 45 76 74 151 147 138 138 155 150 142 142 158 154 145 145 157 153 144 144 157 152 143 143 24 53 72 74 22 53 75 77 20 54 77 79 13 48 68 69 7 43 60 60 138 131 122 122 142 135 126 126 146 139 129 129 144 137 127 127 142 135 125 126 86 Johnson Controls Unitary Products 83 80 77 74 17 47 57 55 17 50 61 59 16 52 65 63 9 46 53 53 2 39 42 42 Sensible Capacity (MBH)* Return Dry Bulb (°F) 71 68 13.4 91 80 70 59 48 38 13.1 120 109 98 88 77 66 13.0 138 134 123 112 101 91 13.0 138 137 126 116 105 94 13.5 100 87 75 62 50 37 13.2 131 118 106 93 80 68 13.0 142 139 132 119 107 94 13.0 142 141 136 123 111 98 13.5 109 95 80 65 51 36 13.2 142 128 113 98 84 69 13.1 145 145 141 126 112 97 13.1 145 145 145 131 116 101 13.5 115 99 82 66 49 32 13.2 147 133 116 100 83 66 13.1 144 144 142 126 109 92 13.1 144 144 144 128 111 94 13.5 122 103 84 66 47 28 13.2 152 138 119 101 82 63 13.1 143 143 143 125 106 88 13.0 143 143 143 125 106 88 Temperature of Air on Condenser Coil 115°F 16.7 85 74 63 53 42 31 16.2 114 103 93 82 71 61 16.0 122 118 107 97 86 75 16.1 122 118 108 97 86 75 16.8 95 82 70 57 44 32 16.4 127 115 102 89 77 64 16.1 126 124 118 106 93 80 16.2 126 124 118 106 93 81 16.9 105 91 76 61 47 32 16.5 139 126 111 97 82 68 16.2 129 129 129 115 100 85 16.3 129 129 129 115 100 86 17.0 111 94 77 61 44 28 16.6 137 130 113 97 80 64 16.3 127 127 127 111 94 78 16.4 127 127 127 111 94 78 17.0 116 97 79 60 42 23 16.6 135 134 115 97 78 59 16.3 125 125 125 107 88 70 16.4 126 126 126 107 88 70 86 83 80 77 74 27 56 80 84 24 55 81 85 22 55 83 87 16 50 76 78 10 45 69 69 21 50 65 65 19 51 68 68 18 53 71 71 11 47 61 61 4 41 51 51 * These capacities are gross ratings. For net capacity, deduct air blower motor, MBH = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. † These ratings include condenser fan motors and the compressor motors but not the supply air blower motor. 17 246645-YTG-C-0708 TABLE 10: ELECTRICAL DATA DM078 (6-1/2 TON) STD EFFICIENCY W/O PWRD CONVENIENCE OUTLET MCA Min. Circuit Supply Pwr Pwr w/Power Ampacity Blower Exh Conv Electric Heater Actual Heater Exhaust Voltage Motor FLA Motor Outlet (Amps) KW Amps Model No. (Amps) RLA LRA FLA 1.5 2 1.5 2 1.5 2 FLA FLA ea. ea. ea. HP HP HP HP HP HP None --38.0 40.0 43.5 45.5 2TP04520925 6.8 18.9 38.0 40.0 43.5 45.5 12.8 110.0 1.5 6.2 8.2 5.5 0.0 208 2TP04521825 13.5 37.5 54.6 57.1 61.5 64.0 2TP04522425 18 50.0 70.2 72.7 77.1 79.6 2TP04523625 25.5 70.8 96.2 98.7 103.1 105.6 None --38.0 40.0 43.5 45.5 2TP04520925 9 21.7 38.0 40.0 43.5 45.5 12.8 110.0 1.5 6.2 8.2 5.5 0.0 230 2TP04521825 18 43.3 61.9 64.4 68.8 71.3 2TP04522425 24 57.7 79.9 82.4 86.8 89.3 2TP04523625 34 81.8 110.0 112.5 116.9 119.4 None --20.7 21.7 22.9 23.9 2TP04520946 9 11.3 20.7 21.7 22.9 23.9 460 7.1 54.0 0.8 3.1 4.1 2.2 0.0 2TP04521846 18 22.6 30.9 32.2 33.7 34.9 2TP04522446 24 30.1 40 41.2 42.7 44 2TP04523646 34 42.7 55 56.2 57.7 59 None --15.1 16.3 16.9 18.1 2TP04520958 9 9.0 15.1 16.3 16.9 18.1 575 5.1 44.0 0.6 2.4 3.6 1.8 0.0 2TP04521858 18 18.1 24.7 26.2 26.9 28.4 2TP04522458 24 24.1 31.9 33.4 34.1 35.6 2TP04523658 34 34.1 43.9 45.4 46.1 47.6 * Maximum HACR breaker of the same AMP size is applicable. OD Fan Compressors Motors Max Max Fuse* Size Fuse* w/Power Size Exhaust (Amps) (Amps) 1.5 2 1.5 2 HP HP HP HP 50 50 50 50 50 50 50 50 60 60 70 70 80 80 80 80 100 100 110 110 50 50 50 50 50 50 50 50 70 70 70 80 80 90 90 90 110 125 125 125 25 25 25 30 25 25 25 30 35 35 35 35 40 45 45 45 60 60 60 60 20 20 20 20 20 20 20 20 25 30 30 30 35 35 35 40 45 50 50 50 TABLE 11: ELECTRICAL DATA DM078 (6-1/2 TON) STD EFFICIENCY WITH PWRD CONVENIENCE OUTLET MCA Max Max Fuse* Size Supply Pwr Pwr Min. Circuit w/Power Fuse* w/Power Blower Ampacity Exh Conv Electric Heater Actual Heater Exhaust Size Exhaust Voltage Motor FLA Motor Outlet (Amps) Model No. KW Amps (Amps) (Amps) (Amps) RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2 FLA FLA ea. ea. ea. HP HP HP HP HP HP HP HP HP HP None --48.0 50.0 53.5 55.5 60 60 60 60 2TP04520925 6.8 18.9 48.0 50.0 53.5 55.5 60 60 60 60 208 12.8 110.0 1.5 6.2 8.2 5.5 10.0 2TP04521825 13.5 37.5 67.1 69.6 74.0 76.5 70 70 80 80 2TP04522425 18 50.0 82.7 85.2 89.6 92.1 90 90 90 100 2TP04523625 25.5 70.8 108.7 111.2 115.6 118.1 110 125 125 125 None --48.0 50.0 53.5 55.5 60 60 60 60 2TP04520925 9 21.7 48.0 50.0 54.2 56.7 60 60 60 60 230 12.8 110.0 1.5 6.2 8.2 5.5 10.0 2TP04521825 18 43.3 74.4 76.9 81.3 83.8 80 80 90 90 2TP04522425 24 57.7 92.4 94.9 99.3 101.8 100 100 100 110 2TP04523625 34 81.8 122.5 125.0 129.4 131.9 125 125 150 150 None --25.7 26.7 27.9 28.9 30 30 30 35 2TP04520946 9 11.3 25.7 26.7 27.9 28.9 30 30 30 35 460 7.1 54.0 0.8 3.1 4.1 2.2 5.0 2TP04521846 18 22.6 37.2 38.4 39.9 41.2 40 40 40 45 2TP04522446 24 30.1 46.2 47.5 49 50.2 50 50 50 60 2TP04523646 34 42.7 61.2 62.5 64 65.2 70 70 70 70 None --19.1 20.3 20.9 22.1 20 25 25 25 2TP04520958 9 9.0 19.1 20.3 21.1 22.6 20 25 25 25 575 5.1 44.0 0.6 2.4 3.6 1.8 4.0 2TP04521858 18 18.1 29.7 31.2 31.9 33.4 30 35 35 35 2TP04522458 24 24.1 36.9 38.4 39.1 40.6 40 40 40 45 2TP04523658 34 34.1 48.9 50.4 51.1 52.6 50 60 60 60 * Maximum HACR breaker of the same AMP size is applicable. Compressors 18 OD Fan Motors Johnson Controls Unitary Products 246645-YTG-C-0708 TABLE 12: ELECTRICAL DATA - DM090 (7-1/2 TON) STANDARD EFFICIENCY W/O PWRD CONV. OUTLET Compressors Voltage 208 230 460 575 Supply Pwr Exh OD Fan Blower Motor Motor Motors FLA RLA LRA FLA ea. ea. ea. 11.5 11.5 6.4 5.1 84.0 84.0 42.0 34.0 3.5 3.5 1.6 1.3 2 HP 8.2 8.2 4.1 3.6 3 HP 10.9 10.9 5.3 4.1 FLA 5.5 5.5 2.2 1.8 Pwr Conv Outlet Electric Heater Model No. Actual KW Min. Circuit Heater Ampacity (Amps) Amps 2 HP FLA 0.0 0.0 0.0 0.0 3 HP Max Fuse Size MCA w/Power Max Fuse* w/Power Exhaust Exhaust (Amps) Size (Amps) (Amps) 2 HP 3 HP 2 HP 3 HP 2 HP 3 HP None -- -- 41.1 43.8 46.6 49.3 50 50 50 60 2TP04540925 6.8 18.9 41.1 43.8 46.6 49.3 50 50 50 60 2TP04541825 13.5 37.5 57.1 60.5 64.0 67.3 60 70 70 70 2TP04542425 18.0 50.0 72.7 76.1 79.6 83.0 80 80 80 90 2TP04543625 25.5 70.8 98.7 102.1 105.6 109.0 100 110 110 110 None -- -- 41.1 43.8 46.6 49.3 50 50 50 60 2TP04540925 9.0 21.7 41.1 43.8 46.6 49.3 50 50 50 60 2TP04541825 18.0 43.3 64.4 67.8 71.3 74.6 70 70 80 80 2TP04542425 24.0 57.7 82.4 85.8 89.3 92.7 90 90 90 100 2TP04543625 34.0 81.8 112.5 115.9 119.4 122.7 125 125 125 125 None -- -- 21.7 22.9 23.9 25.1 25 25 30 30 2TP04540946 9 11.3 21.7 22.9 23.9 25.1 25 25 30 30 2TP04541846 18 22.6 32.2 33.7 34.9 36.4 35 35 35 40 2TP04542446 24 30.1 41.2 42.7 44 45.5 45 45 45 50 2TP04543646 34 42.7 56.2 57.7 59 60.5 60 60 60 70 None -- -- 17.7 18.2 19.5 20 20 20 20 25 2TP04540958 9 9.0 17.7 18.2 19.5 20 20 20 20 25 2TP04541858 18 18.1 26.2 26.8 28.4 29 30 30 30 30 2TP04542458 24 24.1 33.4 34 35.6 36.2 35 35 40 40 2TP04543658 34 34.1 45.4 46 47.6 48.3 50 50 50 50 TABLE 13: ELECTRICAL DATA - DM090 (7-1/2 TON) STANDARD EFFICIENCY W/PWRD CONV. OUTLET Compressors Voltage 208 230 460 575 Supply OD Fan Pwr Exh Blower Motor Motors Motor FLA RLA LRA FLA ea. ea. ea. 11.5 11.5 6.4 5.1 84.0 84.0 42.0 34.0 3.5 3.5 1.6 1.3 2 HP 8.2 8.2 4.1 3.6 3 HP 10.9 10.9 5.3 4.1 Johnson Controls Unitary Products FLA 5.5 5.5 2.2 1.8 Pwr Conv Outlet Electric Heater Model No. Actual KW Min. Circuit Heater Ampacity (Amps) Amps FLA 10.0 10.0 5.0 4.0 2 HP 3 HP Max Fuse Size Max Fuse* MCA w/Power w/Power Exhaust Exhaust (Amps) Size (Amps) (Amps) 2 HP 3 HP 2 HP 3 HP 2 HP 3 HP None -- -- 51.1 53.8 56.6 59.3 60 60 60 70 2TP04540925 6.8 18.9 51.1 53.8 56.6 59.3 60 60 60 70 2TP04541825 13.5 37.5 69.6 73.0 76.5 79.8 70 80 80 80 2TP04542425 18.0 50.0 85.2 88.6 92.1 95.5 90 90 100 100 2TP04543625 25.5 70.8 111.2 114.6 118.1 121.5 125 125 125 125 None -- -- 51.1 53.8 56.6 59.3 60 60 60 70 2TP04540925 9.0 21.7 51.1 53.8 56.7 60.1 60 60 60 70 2TP04541825 18.0 43.3 76.9 80.3 83.8 87.1 80 90 90 90 2TP04542425 24.0 57.7 94.9 98.3 101.8 105.2 100 100 110 110 2TP04543625 34.0 81.8 125.0 128.4 131.9 135.2 125 150 150 150 None -- -- 26.7 27.9 28.9 30.1 30 30 35 35 2TP04540946 9 11.3 26.7 27.9 28.9 30.1 30 30 35 35 2TP04541846 18 22.6 38.4 39.9 41.2 42.7 40 40 45 45 2TP04542446 24 30.1 47.5 49 50.2 51.7 50 50 60 60 2TP04543646 34 42.7 62.5 64 65.2 66.7 70 70 70 70 None -- -- 21.7 22.2 23.5 24 25 25 25 25 2TP04540958 9 9.0 21.7 22.2 23.5 24 25 25 25 25 2TP04541858 18 18.1 31.2 31.8 33.4 34 35 35 35 35 2TP04542458 24 24.1 38.4 39 40.6 41.2 40 40 45 45 2TP04543658 34 34.1 50.4 51 52.6 53.3 60 60 60 60 19 246645-YTG-C-0708 TABLE 14: ELECTRICAL DATA DM102 (8-1/2 TON) STD EFFICIENCY W/O PWRD CONVENIENCE OUTLET Compressors Voltage 208 230 460 575 OD Fan Motors RLA LRA FLA ea. ea. ea. 11.7 11.7 6.4 5.1 88.0 88.0 42.0 36.0 3.5 3.5 1.6 1.3 Supply Blower Pwr Exh Motor FLA Motor 3 HP 10.9 10.9 5.3 4.1 3 HP 10.9 10.9 5.3 4.1 FLA 5.5 5.5 2.2 1.8 Pwr Conv Outlet MCA w/Power Exhaust (Amps) Min. Circuit Ampacity (Amps) Max Fuse* Size (Amps) Max Fuse Size w/Power Exhaust (Amps) Electric Heater Model No. Actual KW Heater Amps 3 HP 3 HP 3 HP 3 HP 3 HP 3 HP 3 HP 3 HP 0.0 None 2TP04540925 2TP04541825 2TP04542425 2TP04543625 -6.8 13.5 18 25.5 -18.9 37.5 50.0 70.8 44.2 44.2 60.5 76.1 102.1 44.2 44.2 60.5 76.1 102.1 49.7 49.7 67.3 83.0 109.0 49.7 49.7 67.3 83.0 109.0 50 50 70 80 110 50 50 70 80 110 60 60 70 90 110 60 60 70 90 110 0.0 None 2TP04540925 2TP04541825 2TP04542425 2TP04543625 -9 18 24 34 -21.7 43.3 57.7 81.8 44.2 44.2 67.8 85.8 115.9 44.2 44.2 67.8 85.8 115.9 50.4 50.4 74.6 92.7 122.7 50.4 50.4 74.6 92.7 122.7 50 50 70 90 125 50 50 70 90 125 60 60 80 100 125 60 60 80 100 125 0.0 None 2TP04540946 2TP04541846 2TP04542446 2TP04543646 -9 18 24 34 -11.3 22.6 30.1 42.7 22.9 22.9 33.7 42.7 57.7 22.9 22.9 33.7 42.7 57.7 25.1 25.1 36.4 45.5 60.5 25.1 25.1 36.4 45.5 60.5 25 25 35 45 60 25 25 35 45 60 30 30 40 50 70 30 30 40 50 70 0.0 None 2TP04540958 2TP04541858 2TP04542458 2TP04543658 -9 18 24 34 -9.0 18.1 24.1 34.1 18.2 18.2 26.8 34 46 18.2 18.2 26.8 34 46 20 20 29 36.2 48.3 20 20 29 36.2 48.3 20 20 30 35 50 20 20 30 35 50 25 25 30 40 50 25 25 30 40 50 FLA TABLE 15: ELECTRICAL DATA DM102 (8-1/2 TON) STD EFFICIENCY WITH PWRD CONVENIENCE OUTLET Compressors OD Fan Motors Supply Blower Pwr Exh Motor FLA Motor Voltage 208 230 460 575 20 RLA LRA FLA ea. ea. ea. 11.7 11.7 6.4 5.1 88.0 88.0 42.0 36.0 3.5 3.5 1.6 1.3 3 HP 10.9 10.9 5.3 4.1 3 HP 10.9 10.9 5.3 4.1 FLA 5.5 5.5 2.2 1.8 Pwr Conv Outlet Electric Heater Model No. Actual KW Heater Amps FLA 10.0 10.0 10.0 10.0 Min. Circuit Ampacity (Amps) 3 HP MCA w/Power Exhaust (Amps) 3 HP 3 HP 3 HP Max Fuse* Size (Amps) 3 HP 3 HP Max Fuse Size w/Power Exhaust (Amps) 3 HP 3 HP None -- -- 54.2 54.2 59.7 59.7 60 60 70 70 2TP04540925 6.8 18.9 54.2 54.2 59.7 59.7 60 60 70 70 2TP04541825 13.5 37.5 73.0 73.0 79.8 79.8 80 80 80 80 2TP04542425 18 50.0 88.6 88.6 95.5 95.5 90 90 100 100 2TP04543625 25.5 70.8 114.6 114.6 121.5 121.5 125 125 125 125 None -- -- 54.2 54.2 59.7 59.7 60 60 70 70 2TP04540925 9 21.7 54.2 54.2 59.7 59.7 60 60 70 70 2TP04541825 18 43.3 80.3 80.3 87.1 87.1 90 90 90 90 2TP04542425 24 57.7 98.3 98.3 105.2 105.2 100 100 110 110 2TP04543625 34 81.8 128.4 128.4 135.2 135.2 150 150 150 150 None -- -- 27.9 27.9 30.1 30.1 30 30 35 35 2TP04540946 9 11.3 27.9 27.9 30.1 30.1 30 30 35 35 2TP04541846 18 22.6 39.9 39.9 42.7 42.7 40 40 45 45 2TP04542446 24 30.1 49 49 51.7 51.7 50 50 60 60 2TP04543646 34 42.7 64 64 66.7 66.7 70 70 70 70 None -- -- 22.2 22.2 24 24 25 25 25 25 2TP04540958 9 9.0 22.2 22.2 24 24 25 25 25 25 2TP04541858 18 18.1 31.8 31.8 34 34 35 35 35 35 2TP04542458 24 24.1 39 39 41.2 41.2 40 40 45 45 2TP04543658 34 34.1 51 51 53.3 53.3 60 60 60 60 Johnson Controls Unitary Products 246645-YTG-C-0708 TABLE 16: ELECTRICAL DATA DM120 (10 TON) STD EFFICIENCY W/O PWRD CONVENIENCE OUTLET Supply Pwr Min. Circuit Pwr Blower Ampacity Exh Conv Electric Heater Actual Heater Voltage Motor FLA Motor Outlet (Amps) KW Amps Model No. RLA LRA FLA 2 3 2 3 FLA FLA ea. ea. ea. HP HP HP HP None --51.9 54.6 2TP04521825 13.5 37.5 57.1 60.5 16.3 150.0 3.5 8.2 10.9 5.5 0.0 208 2TP04522425 18 50.0 72.7 76.1 2TP04523625 25.5 70.8 98.7 102.1 2TP04525425 40.6 112.7 151.1 154.5 None --51.9 54.6 2TP04521825 18 43.3 64.4 67.8 16.3 150.0 3.5 8.2 10.9 5.5 0.0 230 2TP04522425 24 57.7 82.4 85.8 2TP04523625 34 81.8 112.5 115.9 2TP04525425 129.9 140.2 143.5 54 None --33.2 34.4 2TP04521846 18 22.6 33.2 34.4 11.5 75.0 1.6 4.1 5.3 2.2 0.0 460 2TP04522446 24 30.1 41.2 42.7 2TP04523646 34 42.7 56.2 57.7 2TP04525446 54 67.8 70.1 71.6 None --22.2 22.7 2TP04521858 18 18.1 26.2 26.8 7.1 62.0 1.3 3.6 4.1 1.8 0.0 575 2TP04522458 24 24.1 33.4 34 2TP04523658 34 34.1 45.4 46 2TP04525458 54 54.2 56.5 57.1 Maximum HACR breaker of the same AMP size is applicable. * OD Fan Compressors Motors MCA w/Power Exhaust (Amps) 2 3 HP HP 57.4 60.1 64.0 67.3 79.6 83.0 105.6 109.0 158.0 161.4 57.4 60.1 71.3 74.6 89.3 92.7 119.4 122.7 147.0 150.4 35.4 36.6 35.4 36.6 44 45.5 59 60.5 72.8 74.3 24 24.5 28.4 29 35.6 36.2 47.6 48.3 58.7 59.3 Max Max Fuse* Size Fuse* w/Power Size Exhaust (Amps) (Amps) 2 3 2 3 HP HP HP HP 60 70 70 70 60 70 70 70 80 80 80 90 100 110 110 110 175 175 175 175 60 70 70 70 70 70 80 80 90 90 90 100 125 125 125 125 150 175 175 175 40 45 45 45 40 45 45 45 45 45 45 50 60 60 60 70 80 80 80 80 25 25 30 30 30 30 30 30 35 35 40 40 50 50 50 50 70 70 70 70 TABLE 17: ELECTRICAL DATA DM120 (10 TON) STD EFFICIENCY WITH PWRD CONVENIENCE OUTLET Supply Pwr Pwr Blower Exh Conv Electric Heater Actual Heater Voltage Motor FLA Motor Outlet KW Model No. Amps RLA LRA FLA 2 3 FLA FLA ea. ea. ea. HP HP None --2TP04521825 13.5 37.5 16.3 150.0 3.5 8.2 10.9 5.5 10.0 208 2TP04522425 18 50.0 2TP04523625 25.5 70.8 2TP04525425 40.6 112.7 None --2TP04521825 18 43.3 16.3 150.0 3.5 8.2 10.9 5.5 10.0 230 2TP04522425 24 57.7 2TP04523625 34 81.8 2TP04525425 129.9 54 None --2TP04521846 18 22.6 11.5 75.0 1.6 4.1 5.3 2.2 5.0 460 2TP04522446 24 30.1 2TP04523646 34 42.7 2TP04525446 54 67.8 None --2TP04521858 18 18.1 7.1 62.0 1.3 3.6 4.1 1.8 4.0 575 2TP04522458 24 24.1 2TP04523658 34 34.1 2TP04525458 54 54.2 * Maximum HACR breaker of the same AMP size is applicable. Compressors OD Fan Motors Johnson Controls Unitary Products Min. Circuit Ampacity (Amps) 2 HP 61.9 69.6 85.2 111.2 163.6 61.9 76.9 94.9 125.0 152.7 38.2 38.4 47.5 62.5 76.3 26.2 31.2 38.4 50.4 61.5 3 HP 64.6 73.0 88.6 114.6 167.0 64.6 80.3 98.3 128.4 156.0 39.4 39.9 49 64 77.8 26.7 31.8 39 51 62.1 MCA w/Power Exhaust (Amps) 2 3 HP HP 67.4 70.1 76.5 79.8 92.1 95.5 118.1 121.5 170.5 173.9 67.4 70.1 83.8 87.1 101.8 105.2 131.9 135.2 159.5 162.9 40.4 41.6 41.2 42.7 50.2 51.7 65.2 66.7 79.1 80.6 28 28.5 33.4 34 40.6 41.2 52.6 53.3 63.7 64.3 Max Max Fuse* Size Fuse* w/Power Size Exhaust (Amps) (Amps) 2 3 2 3 HP HP HP HP 70 80 80 80 70 80 80 80 90 90 100 100 125 125 125 125 175 175 175 175 70 80 80 80 80 90 90 90 100 100 110 110 125 150 150 150 175 175 175 175 45 50 50 50 45 50 50 50 50 50 60 60 70 70 70 70 90 90 90 90 30 30 35 35 35 35 35 35 40 40 45 45 60 60 60 60 70 70 70 70 21 246645-YTG-C-0708 TABLE 18: ELECTRICAL DATA DM150 (12-1/2 TON) STD EFFICIENCY W/O PWRD CONVENIENCE OUTLET MCA Max Min. Circuit Supply Pwr Pwr w/Power Fuse* Ampacity Blower Exh Conv Electric Heater Actual Heater Exhaust Size Voltage (Amps) Motor FLA Motor Outlet KW Amps Model No. (Amps) (Amps) RLA LRA FLA 3 5 3 5 3 5 3 5 FLA FLA ea. ea. ea. HP HP HP HP HP HP HP HP None --62.9 68.1 68.4 73.6 80 80 2TP04521825 13.5 37.5 62.9 68.1 68.4 73.8 80 80 0.0 20.0 146.0 3.5 10.9 16.1 5.5 208 2TP04522425 18 50.0 76.1 82.6 83.0 89.5 80 90 2TP04523625 25.5 70.8 102.1 108.6 109.0 115.5 110 110 2TP04525425 40.6 112.7 154.5 161.0 161.4 167.9 175 175 None --62.9 68.1 68.4 73.6 80 80 2TP04521825 18 43.3 67.8 74.3 74.6 81.1 80 80 20.0 146.0 3.5 10.9 16.1 5.5 0.0 230 2TP04522425 24 57.7 85.8 92.3 92.7 99.2 90 100 2TP04523625 34 81.8 115.9 122.4 122.7 129.2 125 125 2TP04525425 129.9 143.5 150.0 150.4 156.9 175 175 54 None --27.4 30.2 29.6 32.4 35 35 2TP04521846 18 22.6 33.7 37.2 36.4 39.9 35 40 8.4 73.0 1.6 5.3 8.1 2.2 0.0 460 2TP04522446 24 30.1 42.7 46.2 45.5 49 45 50 2TP04523646 34 42.7 57.7 61.2 60.5 64 60 70 2TP04525446 54 67.8 71.6 75.1 74.3 77.8 80 90 None --21.8 23.7 23.6 25.5 25 30 2TP04521858 18 18.1 26.8 29.2 29 31.4 30 30 6.7 60.0 1.3 4.1 6.0 1.8 0.0 575 2TP04522458 24 24.1 34 36.4 36.2 38.6 35 40 2TP04523658 34 34.1 46 48.4 48.3 50.6 50 50 2TP04525458 54 54.2 57.1 59.5 59.3 61.7 70 70 * Maximum HACR breaker of the same AMP size is applicable. OD Fan Compressors Motors Max Fuse Size w/Power 3 5 HP HP 80 90 80 90 90 90 110 125 175 175 80 90 80 90 100 100 125 150 175 175 35 40 40 40 50 50 70 70 80 90 30 30 30 35 40 40 50 60 70 70 TABLE 19: ELECTRICAL DATA DM150 (12-1/2 TON) STD EFFICIENCY W/PWRD CONVENIENCE OUTLET MCA Max Min. Circuit Supply Pwr Pwr w/Power Fuse* Ampacity Blower Exh Conv Electric Heater Actual Heater Exhaust Size Voltage (Amps) Motor FLA Motor Outlet KW Amps Model No. (Amps) (Amps) RLA LRA FLA 3 5 3 5 3 5 3 5 FLA FLA ea. ea. ea. HP HP HP HP HP HP HP HP None --72.9 78.1 78.4 83.6 90 90 2TP04521825 13.5 37.5 73.0 79.5 79.8 86.3 90 90 20.0 146.0 3.5 10.9 16.1 5.5 10.0 208 2TP04522425 18 50.0 88.6 95.1 95.5 102.0 90 100 2TP04523625 25.5 70.8 114.6 121.1 121.5 128.0 125 125 2TP04525425 40.6 112.7 167.0 173.5 173.9 180.4 175 175 None --72.9 78.1 78.4 83.6 90 90 2TP04521825 18 43.3 80.3 86.8 87.1 93.6 90 90 20.0 146.0 3.5 10.9 16.1 5.5 10.0 230 2TP04522425 24 57.7 98.3 104.8 105.2 111.7 100 110 2TP04523625 34 81.8 128.4 134.9 135.2 141.7 150 150 2TP04525425 129.9 156.0 162.5 162.9 169.4 175 175 54 None --32.4 35.2 34.6 37.4 40 40 2TP04521846 18 22.6 39.9 43.4 42.7 46.2 40 45 8.4 73.0 1.6 5.3 8.1 2.2 5.0 460 2TP04522446 24 30.1 49 52.5 51.7 55.2 50 60 2TP04523646 34 42.7 64 67.5 66.7 70.2 70 70 2TP04525446 54 67.8 77.8 81.3 80.6 84.1 90 90 None --25.8 27.7 27.6 29.5 30 30 2TP04521858 18 18.1 31.8 34.2 34 36.4 35 35 6.7 60.0 1.3 4.1 6.0 1.8 4.0 575 2TP04522458 24 24.1 39 41.4 41.2 43.6 40 45 2TP04523658 34 34.1 51 53.4 53.3 55.6 60 60 2TP04525458 54 54.2 62.1 64.5 64.3 66.7 70 70 * Maximum HACR breaker of the same AMP size is applicable. Compressors OD Fan Motors Max Fuse Size w/Power 3 5 HP HP 90 100 90 100 100 110 125 150 175 200 90 100 90 100 110 125 150 150 175 175 40 45 45 50 60 60 70 80 90 90 30 35 35 40 45 45 60 60 70 70 NOTES FOR TABLE 21 THROUGH TABLE 30: TABLE 20: ELECTRIC HEAT MULTIPLIERS VOLTAGE NOMINAL 240 480 600 RATING 208 230 0.75 0.92 460 0.92 575 0.92 NOTE: Electric heaters are rated at nominal voltage. Use this table to determine the electric heat capacity for heaters supplied at lower voltages. 22 • Blower performance includes dry coil and 2” throwaway filters. • Blower performance for gas heat includes the maximum number of heat tubes available for each tonnage. • ESP (External Static Pressure) given is that available for the supply and return air duct system. All internal resistances have been deducted from the total static pressure of the blower. kW Cap. Multiplier Johnson Controls Unitary Products 0.2 0.4 0.6 0.8 1.0 External Static Pressure 1.2 1.4 1.6 1.8 Johnson Controls Unitary Products 760 1.18 1100 776 1.25 1166 652 707 764 823 885 949 2900 642 0.82 3000 652 0.88 3100 662 0.95 3200 672 1.02 3300 682 1.09 1016 976 917 860 806 1.11 1037 High Horsepower Option Required 745 730 1.05 715 0.98 699 0.92 684 0.86 755 705 659 614 2800 632 0.76 669 0.81 654 0.76 639 0.71 623 0.66 572 ---- 2700 622 0.70 ---- 608 0.61 ---- ---- ---- 600 ---- 2400 ---- ---- ---- ---- ---- 550 ---- 2300 ---- ---- ---- ---- 2600 612 0.64 ---- 2200 ---- ---- ---- 2500 602 0.59 ---- 2100 ---- ---- ---- ---- ---- ---- 2000 971 923 877 832 790 750 712 676 641 825 1.40 1305 815 1.33 1244 805 1.27 1185 795 1.21 1129 786 1.15 1074 776 1.10 1022 766 1.04 756 0.99 746 0.94 736 0.89 727 0.85 717 0.80 707 0.76 697 0.72 687 0.69 968 922 880 843 810 782 758 884 1.61 1499 876 1.52 1417 867 1.44 1339 858 1.36 1266 850 1.28 1197 841 1.22 1133 832 1.15 1074 824 1.09 1019 815 1.04 807 0.99 798 0.94 789 0.90 781 0.87 772 0.84 764 0.81 997 940 884 944 1.86 1731 936 1.79 1666 929 1.72 1602 921 1.65 1539 914 1.58 1476 906 1.52 1414 899 1.45 1353 891 1.39 1292 884 1.32 1232 876 1.26 1172 869 1.19 1113 861 1.13 1055 854 1.07 846 1.01 839 0.95 996 1.66 1544 1046 1.78 1655 1094 1.96 1827 989 1.60 1493 1041 1.71 1597 1088 1.90 1770 983 1.55 1444 1035 1.65 1541 1083 1.84 1713 976 1.50 1395 1030 1.59 1485 1078 1.78 1656 970 1.44 1346 1024 1.53 1430 1073 1.71 1599 963 1.39 1299 1019 1.48 1377 1067 1.65 1541 957 1.34 1252 1013 1.42 1324 1062 1.59 1484 987 2.00 1862 1047 2.12 1974 981 1.92 1793 1041 2.06 1918 974 1.85 1725 1034 2.00 1862 ---- ---- ---- ---- ---- ---- ---- ---- ---- 967 1.78 1660 1028 1.94 1807 1073 2.10 1956 960 1.71 1597 1021 1.88 1753 1068 2.03 1894 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 954 1.65 1537 1015 1.82 1700 1062 1.97 1833 1109 2.14 1999 947 1.59 1479 1008 1.77 1647 1057 1.90 1773 1104 2.08 1941 940 1.53 1423 1002 1.71 1595 1051 1.84 1713 1099 2.02 1884 934 1.47 1369 927 1.41 1318 920 1.36 1269 913 1.31 1223 907 1.26 1179 900 1.22 1137 893 1.18 1097 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 1900 CFM TABLE 21: DM078 (6-1/2 TON) SIDE SHOT BLOWER PERFORMANCE 246645-YTG-C-0708 23 24 1324 ---- 2996 3161 4400 1299 3.21 4500 1329 3.39 High Horsepower Option Required ---- ---- ---- ---- ------- ---- ------- ---- ------- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ------- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1336 3.28 3058 1306 3.11 2901 1371 3.32 3091 ---- ---- ---- 2835 ---- ---- ---- 2678 ---- ---- ---- 4300 1269 3.04 ---- ---- 4200 1240 2.87 1277 2.95 2748 1342 3.15 2939 1406 3.33 3102 ---- 2525 ---- ---- 4100 1211 2.71 1249 2.79 2600 1314 2.99 2790 1377 3.17 2953 1439 3.32 3097 ---- 1221 2.63 2455 1286 2.84 2645 1349 3.01 2809 1411 3.17 2952 1471 3.31 3081 ---- 2377 ---- 2232 ---- 3900 1155 2.39 ---- 4000 1183 2.55 ---- 1140 2.13 1990 1205 2.33 2170 1269 2.58 2401 1330 2.73 2544 1390 2.87 2673 1448 3.00 2794 1503 3.13 2914 1556 3.26 3039 ---- 1581 1115 2.01 1870 1179 2.20 2049 1243 2.44 2273 1304 2.59 2416 1364 2.73 2546 1422 2.86 2667 1478 2.99 2787 1531 3.12 2912 1194 2.48 2315 1258 2.69 2505 1322 2.86 2669 1383 3.02 2812 1443 3.15 2941 1501 3.29 3062 1556 1531 1065 1.76 1639 1130 1.95 1819 1193 2.13 1987 1255 2.30 2141 1314 2.47 2304 1372 2.60 2425 1428 2.73 2545 1481 2.86 2670 1089 1.88 1753 1154 2.07 1932 1218 2.25 2101 1279 2.46 2293 1339 2.60 2422 1397 2.73 2544 1452 2.86 2664 1505 2.99 2789 1507 1041 1.64 1528 1106 1.83 1708 1169 2.01 1877 1231 2.18 2030 1290 2.32 2163 1348 2.48 2311 1404 2.61 2431 1457 2.74 2555 1461 1.41 1317 1060 1.61 1497 1123 1.79 1666 1185 1.95 1819 1244 2.09 1952 1302 2.21 2060 1358 2.38 2214 1411 2.51 2339 1484 1439 1.30 1216 1038 1.50 1396 1101 1.68 1565 1163 1.84 1718 1222 1.99 1851 1280 2.10 1960 1336 2.27 2113 1389 2.40 2238 1398 1378 1359 1341 1418 996 1.29 1206 1059 1.47 1375 1121 1.64 1528 1181 1.78 1661 1238 1.90 1769 1294 2.06 1922 1347 2.20 2046 1292 1307 1.20 1119 1016 1.39 1299 1080 1.58 1468 1141 1.74 1621 1201 1.88 1755 1259 2.00 1863 1314 2.16 2015 1368 2.30 2140 1.10 1026 1.11 1030 1020 1.29 1199 1082 1.45 1353 1142 1.59 1486 1200 1.71 1594 1255 1.87 1746 1308 2.01 1871 1117 1064 1.36 1270 1124 1.51 1403 1182 1.62 1511 1237 1.78 1664 1290 1.92 1789 976 1.20 1116 1039 1.38 1285 1101 1.54 1438 1161 1.69 1571 1219 1.80 1680 1274 1.97 1832 1327 2.10 1957 957 1031 1.20 1117 1090 1.34 1251 1148 1.46 1359 1204 1.62 1508 1257 1.75 1633 1015 1.12 1047 1075 1.27 1180 1133 1.38 1288 1188 1.54 1434 1241 1.67 1559 2053 3800 1127 2.20 850 936 964 894 1.11 1039 1047 1.28 1192 1107 1.42 1325 1164 1.54 1433 1220 1.70 1584 1273 1.83 1709 1002 1.20 985 969 1.03 954 0.96 ---- 1927 3700 1101 2.07 0.91 1.00 948 870 795 725 1017 1.52 1421 1082 1.72 1601 1146 1.90 1769 1207 2.06 1923 1267 2.21 2056 1325 2.32 2164 1380 2.49 2320 1434 2.62 2445 995 973 952 931 911 892 939 1.02 922 0.93 906 0.85 890 0.78 1167 2.27 2113 1232 2.54 2369 1295 2.72 2532 1357 2.87 2676 1416 3.01 2805 1474 3.14 2926 1530 3.27 3046 1583 3.40 3171 1804 1342 3600 1074 1.94 3300 1.44 1235 1684 999 3200 1.32 1131 3500 1048 1.81 975 3100 1.21 1030 1567 951 3000 1.11 840 933 3400 1023 1.68 929 2900 0.90 1.00 1453 907 2800 750 664 1.56 865 885 2700 0.81 0.71 768 690 615 545 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 3.27 3.14 3.01 2.89 2.77 2.66 2.55 2.44 2.34 2.25 2.15 2.06 1.98 1.90 845 0.82 0.74 0.66 0.58 826 874 857 841 825 2600 582 504 429 359 2500 0.62 0.54 0.46 0.38 808 2 791 1.8 2400 1.6 2300 1.4 1.82 1.2 774 1.0 External Static Pressure 759 0.8 2200 0.6 2100 0.4 BHP 1.74 0.2 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM 2000 745 0.31 292 811 0.51 478 876 0.71 658 939 0.89 827 1001 1.05 980 1061 1.19 1113 1118 1.31 1221 1174 1.46 1361 1227 1.59 1486 1278 CFM TABLE 22: DM090 (7-1/2 TON) SIDE SHOT BLOWER PERFORMANCE ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 3048 2925 2806 2691 2581 2475 2374 2276 2183 2093 2007 1925 1845 1769 1695 Watts 1622 246645-YTG-C-0708 Johnson Controls Unitary Products 0.2 0.4 0.6 0.8 1.0 External Static Pressure 1.2 1.4 1.6 1.8 Johnson Controls Unitary Products 1698 1118 1826 1141 2.20 2048 1958 1164 2.34 2180 2094 1187 2.49 2316 3500 1054 1.82 3600 1077 1.96 3700 1100 2.10 3800 1123 2.25 1.14 1067 1.06 986 0.98 909 0.90 836 0.82 766 3156 ---- 4500 1302 3.39 Optional Drive Required 2993 ---- 4400 1275 3.21 ---- ---- ---- 2834 1306 3.30 3075 ---- 1337 3.36 3129 ---- 2678 1286 3.11 2900 4300 1248 3.04 ---- ------- ---- ------- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ------- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1417 3.40 3168 1393 3.23 3015 1343 3.07 2861 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1442 3.39 3156 1418 3.23 3007 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1468 3.37 3141 1444 3.21 2996 1421 3.06 2854 1372 2.92 2720 1322 2.77 2578 1406 2.78 2588 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1495 3.36 3128 1471 3.20 2986 1449 3.06 2849 1427 2.91 2716 1385 2.64 2465 1355 2.64 2456 1399 2.91 2717 1365 2.52 2347 1346 2.40 2235 1328 2.28 2128 1334 2.19 2044 1318 2.10 1954 1302 2.01 1869 1287 1.92 1788 1273 1.84 1712 1335 2.50 2333 1349 2.77 2583 1395 3.07 2861 1248 1.68 1569 1260 1.76 1638 1315 2.38 2215 1309 2.26 2111 1292 2.16 2013 1274 2.06 1919 1258 1.96 1830 1243 1.87 1745 1228 1.79 1664 1214 1.70 1587 1304 2.60 2424 1313 2.48 2311 1293 2.36 2200 1274 2.25 2093 1255 2.14 1991 1238 2.03 1893 1221 1.93 1800 1204 1.83 1710 1189 1.74 1625 1174 1.66 1544 1160 1.57 1467 1189 1.55 1445 1201 1.62 1514 1377 2.77 2584 1369 3.07 2865 1365 3.39 3160 1135 1.42 1325 1147 1.50 1394 1327 2.63 2450 1283 2.47 2304 1263 2.35 2189 1243 2.23 2078 1224 2.12 1972 1205 2.01 1869 1187 1.90 1771 1170 1.80 1678 1154 1.70 1589 1139 1.61 1504 1318 2.91 2711 1311 3.18 2966 4200 1222 2.87 1110 1.44 1346 1124 1.53 1423 1345 2.92 2720 1392 3.40 3171 2526 1261 2.95 2749 1085 1.29 1203 1097 1.37 1273 1300 2.73 2546 1277 2.59 2418 1256 2.46 2294 1234 2.33 2175 1214 2.21 2059 1194 2.09 1949 1175 1.98 1842 1156 1.87 1740 1139 1.76 1642 1122 1.66 1548 1105 1.57 1459 1090 1.47 1374 1367 3.23 3014 4100 1197 2.71 1061 1.30 1216 1075 1.39 1293 1340 3.22 2999 1296 2.86 2670 1273 2.72 2534 1250 2.58 2402 1228 2.44 2274 1206 2.31 2151 1185 2.18 2031 1164 2.06 1916 1145 1.94 1805 1125 1.82 1698 1107 1.71 1596 1089 1.61 1498 1072 1.51 1405 1056 1.41 1316 1040 1.32 1230 1026 1.23 1150 1048 1.23 1143 1036 1.15 1074 1315 3.05 2843 1268 2.84 2647 1.07 1000 1.00 930 1012 1.15 1073 999 986 1293 2.99 2791 2234 1211 2.64 2457 2378 1236 2.79 2601 3900 1147 2.40 1244 2.69 2506 1221 2.54 2370 1198 2.40 2238 1176 2.26 2111 1154 2.13 1987 1133 2.00 1867 1112 1.88 1752 1092 1.76 1641 1073 1.65 1535 1055 1.54 1433 1037 1.43 1335 1020 1.33 1241 1004 1.24 1152 988 973 959 946 934 4000 1171 2.55 2.06 1921 1574 1097 1.93 1797 3400 1033 1.69 1229 1035 1.56 1451 1016 1.44 1345 1455 1076 1.80 1677 991 3200 1.32 1122 1.33 1243 1.23 1145 1.13 1051 1.03 962 0.94 877 0.85 796 0.77 719 0.69 646 0.62 576 3300 1012 1.56 971 3100 1.20 980 963 946 931 916 902 889 877 1020 998 922 829 739 654 573 497 423 354 1340 1055 1.68 1562 952 3000 1.09 0.99 0.89 0.79 0.70 0.62 0.53 0.45 0.38 1.44 934 882 2600 2900 867 2500 899 852 2400 916 838 2300 2800 825 2200 2700 813 2100 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 2000 802 0.31 288 866 0.55 510 923 0.75 700 975 0.93 864 1025 1.08 1007 1074 1.22 1137 1124 1.35 1259 1178 1.48 1378 1237 1.61 1503 CFM TABLE 23: DM102 (8-1/2 TON) SIDE SHOT BLOWER PERFORMANCE 246645-YTG-C-0708 25 26 0.2 0.4 0.6 0.8 1.0 External Static Pressure 1.2 1.4 1.6 1.8 ---- ---- ---- 694 707 720 733 746 759 772 784 797 810 823 836 849 862 875 888 901 3200 3300 3400 3500 3600 3700 3800 3900 4000 4100 4200 4300 4400 4500 4600 4700 4800 4900 5000 2.69 2.56 2.44 2.32 2.21 2.10 2.00 1.90 1.80 1.71 1.62 1.54 1.46 1.38 1.31 1.25 1.18 ---- ---- ---- ---- 2503 2387 2274 2166 2061 1960 1863 1770 1680 1595 1513 1435 1361 1290 1224 1161 1102 ---- ---- ---- ---- ---- ---- ---- 741 1.20 1122 816 1.35 1256 865 1.46 1365 923 1.69 1571 971 1.91 1784 1035 2.04 1906 1092.2 2.26 2110 971 3.03 2823 1021 3.32 3093 ---- ---- ---- ---- 957 2.88 2687 1007 3.15 2941 1036 3.33 3100 ------- ------- ------- ---- 943 2.74 2556 993 3.00 2795 1024 3.18 2964 1070 3.40 3166 ---- 929 2.61 2430 979 2.85 2654 1012 3.04 2832 1058 3.25 3032 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 915 2.48 2308 965 2.70 2519 1001 2.90 2705 1047 3.11 2902 1082 3.41 3175 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 901 2.35 2191 951 2.56 2390 989 2.77 2581 1036 2.98 2776 1072 3.25 3032 1102 3.42 3184 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 887 2.23 2079 937 2.43 2266 978 2.64 2463 1024 2.85 2654 1062 3.11 2895 1093 3.29 3065 1125 3.40 3171 873 2.12 1972 923 2.30 2148 966 2.52 2348 1013 2.72 2536 1052 2.96 2763 1084 3.16 2949 1118 3.28 3061 859 2.01 1869 909 2.18 2035 955 2.40 2238 1001 2.60 2422 1042 2.83 2637 1076 3.04 2838 1112 3.17 2953 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 845 1.90 1771 895 2.07 1928 943 2.29 2132 990 2.48 2311 1032 2.70 2516 1067 2.93 2729 1106 3.06 2848 1147.2 3.38 3148 831 1.80 1678 881 1.96 1827 932 2.18 2031 979 2.37 2205 1022 2.58 2402 1058 2.82 2625 1099 2.95 2747 1142.2 3.26 3040 817 1.70 1589 867 1.86 1731 920 2.07 1934 967 2.26 2103 1012 2.46 2293 1050 2.71 2524 1093 2.84 2649 1137.2 3.15 2934 803 1.61 1505 853 1.76 1641 909 1.98 1841 956 2.15 2005 1002 2.35 2190 1041 2.60 2427 1086 2.74 2554 1132.2 3.04 2832 789 1.53 1426 839 1.67 1556 897 1.88 1753 944 2.05 1911 992 2.24 2092 1032 2.50 2334 1080 2.64 2462 1127.2 2.93 2732 775 1.45 1351 825 1.59 1477 886 1.79 1669 933 1.95 1821 982 2.15 2001 1023 2.41 2244 1073 2.55 2373 1122.2 2.83 2634 761 1.37 1281 811 1.51 1404 874 1.70 1589 922 1.86 1735 972 2.05 1915 1015 2.31 2158 1067 2.45 2287 1117.2 2.72 2540 747 1.30 1216 797 1.43 1336 863 1.62 1514 910 1.77 1653 962 1.97 1834 1006 2.23 2076 1061 2.37 2205 1112.2 2.63 2448 733 1.24 1156 783 1.37 1274 851 1.55 1443 899 1.69 1575 952 1.89 1760 997 2.14 1997 1054 2.28 2125 1107.2 2.53 2360 719 1.18 1100 769 1.31 1218 840 1.48 1376 887 1.61 1501 943 1.81 1691 988 2.06 1922 1048 2.20 2049 1102.2 2.44 2274 705 1.13 1049 755 1.25 1167 828 1.41 1314 876 1.54 1431 933 1.75 1628 980 1.99 1851 1041 2.12 1976 1097.2 2.35 2190 High Horsepower Option Required ---- 3100 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 3000 CFM TABLE 24: DM120 (10 TON) SIDE SHOT BLOWER PERFORMANCE 246645-YTG-C-0708 Johnson Controls Unitary Products 0.4 0.6 0.8 1.0 1.2 External Static Pressure 1.4 1.6 1.8 2.0 Johnson Controls Unitary Products ---- ---- ---- ---- ---- ---- ---- 3900 ---- 4000 ---- 4100 ---- 4200 ---- 4300 ---- 4400 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 874 1.93 1801 927 2.04 1906 984 2.27 2113 1037 2.41 2245 1089 2.57 2399 1138 2.68 2499 1178 2.82 2628 885 2.12 1973 932 2.27 2115 982 2.45 2283 1035 2.68 2494 1083 2.82 2626 1130 2.98 2774 1171 3.10 2887 1212 3.29 3066 870 2.01 1877 917 2.18 2028 968 2.34 2182 1022 2.57 2392 1071 2.71 2524 1120 2.87 2672 1163 2.98 2780 1204 3.16 2947 855 1.92 1786 903 2.09 1947 954 2.24 2085 1009 2.46 2295 1060 2.60 2427 1109 2.76 2576 1155 2.88 2680 1195 3.04 2834 840 1.82 1699 888 2.01 1871 941 2.14 1993 997 2.36 2202 1048 2.50 2334 1099 2.67 2485 1146 2.77 2586 1186 2.93 2728 868 2.28 2121 931 2.45 2283 975 2.58 2409 1023 2.81 2616 1074 3.03 2828 1117 3.18 2960 1160 3.34 3111 1196 3.48 3245 1239 3.71 3462 851 2.19 2042 915 2.33 2175 961 2.47 2305 1009 2.68 2501 1061 2.91 2712 1106 3.05 2844 1150 3.21 2993 1188 3.35 3119 1230 3.57 3324 834 2.11 1970 900 2.22 2072 946 2.37 2207 996 2.56 2390 1048 2.79 2601 1094 2.93 2733 1140 3.09 2881 1179 3.22 3000 1221 3.42 3192 ---- ---- ---- ---- ---- High Horsepower Option Required ---- 6200 1098 4.86 4531 1169 5.09 4744 1204 5.29 4927 1236 5.61 5231 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ------- ---- 6100 1082 4.64 4326 1152 4.87 4539 1189 5.09 4745 1222 5.39 5027 ---- ---- 6000 1066 4.43 4127 1136 4.66 4341 1174 4.90 4567 1207 5.18 4828 1243 5.48 5108 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 5900 1050 4.22 3936 1119 4.45 4149 1159 4.71 4393 1193 4.97 4635 1229 5.27 4917 1267 5.47 5101 ---- ---- ------- ------- ---- 5800 1033 4.02 3751 1102 4.25 3965 1143 4.53 4224 1178 4.77 4447 1215 5.07 4731 1254 5.28 4918 1279 5.42 5050 ---- ---- 5700 1017 3.83 3574 1085 4.06 3788 1128 4.35 4058 1164 4.58 4265 1201 4.88 4549 1241 5.08 4740 1267 5.23 4872 1293 5.50 5125 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 5600 1001 3.65 3403 1069 3.88 3618 1113 4.18 3897 1149 4.39 4089 1188 4.69 4372 1228 4.90 4566 1256 5.04 4698 1283 5.30 4938 ---- ---- ------- ---- 5400 968 3.31 3083 1035 3.54 3298 1083 3.85 3587 1120 4.03 3753 1160 4.33 4032 1202 4.54 4231 1233 4.68 4363 1262 4.91 4580 1278 5.20 4848 ---- 5500 984 3.48 3240 1052 3.71 3455 1098 4.01 3740 1135 4.20 3918 1174 4.51 4200 1215 4.72 4396 1244 4.86 4528 1273 5.10 4757 1286 5.41 5044 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 5300 952 3.15 2934 1018 3.38 3149 1067 3.69 3438 1106 3.85 3593 1147 4.15 3869 1189 4.37 4070 1221 4.51 4202 1252 4.73 4409 1270 5.00 4660 1317 5.36 4996 5200 936 2.99 2791 1002 3.23 3007 1052 3.53 3293 1091 3.69 3439 1133 3.98 3711 1177 4.20 3914 1210 4.34 4046 1242 4.55 4244 1262 4.80 4477 1308 5.15 4800 5100 919 2.85 2656 985 3.08 2872 1037 3.38 3152 1077 3.53 3291 1119 3.82 3558 1164 4.04 3763 1198 4.18 3895 1232 4.38 4083 1254 4.61 4301 1300 4.95 4610 5000 903 2.71 2527 968 2.94 2744 1022 3.24 3016 1062 3.38 3148 1105 3.66 3409 1151 3.88 3616 1187 4.02 3748 1222 4.21 3929 1245 4.43 4131 1291 4.75 4427 4900 887 2.58 2406 952 2.81 2622 1007 3.09 2883 1048 3.23 3011 1092 3.50 3265 1138 3.73 3473 1175 3.87 3605 1211 4.05 3779 1237 4.26 3967 1282 4.56 4250 4800 870 2.46 2291 935 2.69 2508 991 2.96 2755 1033 3.09 2879 1078 3.35 3126 1125 3.58 3335 1164 3.72 3467 1201 3.90 3635 1229 4.09 3810 1273 4.38 4080 4700 854 2.34 2184 918 2.58 2401 976 2.82 2631 1019 2.95 2753 1064 3.21 2991 1112 3.43 3201 1152 3.58 3333 1191 3.75 3496 1221 3.93 3659 1265 4.20 3916 4600 838 2.23 2083 901 2.47 2301 961 2.69 2511 1004 2.82 2633 1051 3.07 2862 1099 3.30 3072 1141 3.44 3204 1181 3.61 3362 1212 3.77 3515 1256 4.03 3758 4500 822 2.13 1990 885 2.37 2208 946 2.57 2395 990 2.70 2518 1037 2.94 2736 1087 3.16 2948 1129 3.30 3080 1171 3.47 3234 1204 3.62 3377 1247 3.87 3607 ---- 3800 ---- RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 0.2 3700 ---- CFM TABLE 25: DM150 (12-1/2 TON) SIDE SHOT BLOWER PERFORMANCE 246645-YTG-C-0708 27 28 0.2 0.4 0.6 0.8 1.0 External Static Pressure 1.2 1.4 1.6 ---- ---- ---- ---- 728 739 750 761 772 784 795 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300 ---- 1.36 1.26 1.16 1.06 0.96 0.86 0.76 ---- ---- ---- ---- ---- ---- ---- ---- 1269 1175 1080 987 894 801 709 ---- ---- ---- ---- ---- ---- ---- ---- 836 825 813 801 790 778 767 755 743 732 720 ---- ---- ---- Std HP Motor 1.5 Motor Efficiency 0.8 High Horsepower Option Required ---- ---- 2100 ---- ---- 2000 ---- 964 895 828 763 699 ---- ---- ---- 1.52 1417 1.43 1336 1.35 1258 1.27 1182 1.19 1107 1.11 1035 1.03 0.96 0.9 0.82 0.75 ---- ---- ---- ---0.8 0.9 698 946 891 839 789 742 1.5 1400 890 1.67 1552 879 1.58 1475 868 857 1.42 1327 846 1.35 1257 834 1.28 1190 823 1.21 1125 812 1.14 1063 801 1.08 1003 789 1.01 778 0.96 767 756 0.85 745 733 0.75 0.9 1.1 825 1030 975 922 872 1211 1.68 1562 1.59 1487 1.52 1414 1.44 1344 1.37 1276 1.3 947 1.85 1721 937 1.76 1640 926 916 906 896 886 875 865 1.23 1148 855 1.17 1088 845 835 1.05 824 0.99 814 0.94 804 963 931 1.21 1124 1.4 980 1.37 1279 1019 1.51 1409 1.5 1395 1031 1.63 1521 1301 1000 1.56 1454 1036 1.69 1578 993 987 1.43 1336 1025 1.57 1465 1.6 1491 1019 1.76 1641 1053 1.88 1755 992 1.75 1627 1032 1.9 939 2.05 1908 935 1.96 1827 ---- ------- ------- ---- 931 1.87 1748 1023 2.06 1917 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1769 1045 2.04 1906 927 1.79 1671 1015 1.98 1842 923 1.71 1596 1008 1.9 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1771 1064 2.01 1878 985 1.67 1558 1026 1.83 1705 1059 1.95 1816 977 969 1.53 1426 1013 1.69 1577 1047 1.82 1695 962 1.46 1363 1006 1.63 1515 1042 1.76 1636 954 946 1.33 1240 939 1.27 1181 918 1.63 1523 1000 1.82 1697 1039 1.97 1838 914 1.56 1452 910 1.48 1384 906 1.41 1317 902 1.34 1253 898 1.28 1191 894 1.21 1131 889 1.15 1073 885 1.09 1017 881 1.03 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 1900 CFM TABLE 26: DM078 (6-1/2 TON) DOWN SHOT BLOWER PERFORMANCE 246645-YTG-C-0708 Johnson Controls Unitary Products 0.2 0.4 0.6 0.8 1.0 External Static Pressure 1.2 1.4 1.6 1.8 Johnson Controls Unitary Products 980 1739 1861 1986 2114 2314 2473 2636 2806 1.87 3300 1115 3400 1143 2.00 3500 1172 2.13 3600 1201 2.27 3700 1223 2.48 3800 1251 2.65 3900 1280 2.83 4000 1308 3.01 975 890 810 735 979 904 1066 1.21 1129 1138 1.34 1249 1214 1.43 1330 1282 1.69 1574 1364 1.87 1741 1458 2.08 1936 1047 1.13 1054 1120 1.26 1174 1196 1.35 1255 1266 1.60 1492 1349 1.78 1658 1443 1.99 1854 1036 1.23 1143 1106 1.39 1293 1179 1.52 1414 1255 1.60 1495 1317 1.87 1745 1400 2.05 1911 1493 2.26 2107 1015 1.14 1059 1086 1.30 1208 1158 1.43 1329 1234 1.51 1410 1299 1.78 1658 1381 1.96 1824 1475 2.17 2020 995 1.05 977 0.97 1.14 1063 1057 1.32 1232 1128 1.48 1382 1201 1.61 1503 1277 1.70 1584 1337 1.97 1834 1420 2.15 2000 1513 2.36 2196 1.05 0.95 0.87 0.79 1380 3.24 3021 1446 3.43 3201 1351 3.06 2852 1418 3.25 3032 ---- ------- ------- ------- ------- ------- ---- 1323 2.88 2688 1389 3.08 2868 1454 3.24 3023 1519 3.40 3165 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1295 2.71 2530 1361 2.91 2710 1426 3.07 2865 1491 3.23 3007 1560 3.38 3147 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1267 2.55 2377 1334 2.74 2557 1398 2.91 2713 1464 3.06 2855 1532 3.21 2994 1606 3.37 3142 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1246 2.32 2163 1306 2.59 2411 1371 2.75 2566 1436 2.91 2708 1505 3.06 2848 1579 3.21 2995 1662 3.39 3161 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1218 2.19 2038 1279 2.44 2270 1344 2.60 2426 1409 2.75 2568 1478 2.90 2707 1552 3.06 2854 1635 3.24 3021 1729 3.45 3216 1189 2.06 1916 1261 2.24 2084 1318 2.46 2291 1383 2.61 2433 1451 2.76 2572 1526 2.92 2719 1608 3.10 2886 1702 3.31 3081 1162 1.93 1797 1233 2.11 1965 1304 2.27 2115 1357 2.47 2303 1426 2.62 2443 1500 2.78 2590 1583 2.96 2756 1676 3.17 2952 1134 1.80 1681 1206 1.98 1850 1277 2.15 1999 1349 2.27 2120 1400 2.49 2319 1474 2.65 2467 1557 2.82 2633 1651 3.03 2829 1108 1.68 1569 1179 1.86 1737 1250 2.02 1887 1322 2.15 2008 1399 2.24 2089 1450 2.52 2348 1532 2.70 2515 1626 2.91 2710 1082 1.57 1460 1153 1.75 1629 1224 1.91 1779 1297 2.04 1899 1373 2.12 1980 1425 2.40 2236 1508 2.58 2402 1602 2.79 2598 1057 1.45 1355 1128 1.63 1524 1199 1.80 1674 1271 1.92 1794 1348 2.01 1875 1402 2.28 2128 1485 2.46 2294 1578 2.67 2490 1032 1.35 1254 1104 1.53 1422 1175 1.69 1572 1247 1.82 1693 1323 1.90 1774 1379 2.17 2026 1462 2.35 2192 1556 2.56 2388 1009 1.24 1157 1080 1.42 1325 1151 1.58 1475 1223 1.71 1596 1299 1.80 1677 1358 2.07 1928 1440 2.25 2094 1534 2.46 2290 986 964 943 924 905 High Horsepower Option Required 1620 3200 1087 1.74 1077 1504 982 2800 1.16 1.05 3100 1060 1.61 958 2700 887 798 1392 934 2600 0.95 0.86 1283 911 2500 713 3000 1033 1.49 890 2400 0.77 633 558 2900 1007 1.38 869 2300 0.68 0.60 1178 849 2200 1.26 831 2100 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 2000 814 0.52 488 888 0.71 665 960 0.89 834 1030 1.06 984 1103 1.18 1104 1179 1.27 1185 1253 1.51 1411 1335 1.69 1577 1429 1.90 1773 CFM TABLE 27: DM090 (7-1/2 TON) DOWN SHOT BLOWER PERFORMANCE 246645-YTG-C-0708 29 30 0.2 0.4 0.6 0.8 1.0 External Static Pressure 1.2 1.4 1.6 1.8 948 1046 1875 2016 2162 2314 2473 2636 2870 3067 1.87 3300 1115 3400 1142 2.01 3500 1168 2.16 3600 1196 2.32 3700 1223 2.48 3800 1251 2.65 3900 1280 2.83 4000 1328 3.08 4100 1363 3.29 Optional Drive Required 1611 1740 3200 1089 1.73 1487 2800 1.12 1.02 3100 1064 1.60 991 2700 855 765 1369 969 2600 0.92 0.82 1256 947 2500 679 3000 1039 1.47 926 2400 0.73 513 595 2900 1015 1.35 906 2300 0.55 0.64 1149 888 2200 1.23 856 871 2100 0.78 728 980 894 810 993 0.97 990 908 1074 1.23 1146 1139 1.38 1288 1207 1.53 1427 1282 1.69 1574 1364 1.87 1741 1458 2.08 1936 1058 1.14 1064 1123 1.29 1206 1192 1.44 1345 1266 1.60 1492 1349 1.78 1658 1443 1.99 1854 1044 1.24 1160 1109 1.41 1316 1174 1.56 1458 1243 1.71 1597 1317 1.87 1745 1400 2.05 1911 1493 2.26 2107 1026 1.15 1074 1091 1.32 1230 1156 1.47 1372 1224 1.62 1511 1299 1.78 1658 1381 1.96 1824 1475 2.17 2020 1009 1.06 1.15 1070 1064 1.34 1250 1129 1.51 1406 1194 1.66 1548 1262 1.81 1687 1340 2.02 1883 1415 2.13 1990 1494 2.21 2063 1.05 0.96 0.87 ---- ---- ---- ---- ---- ------- ------- ---- ---- ---- 1374 3.17 2952 1450 3.43 3202 1408 3.37 3143 ---- 1341 2.97 2767 1416 3.24 3016 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1295 2.71 2530 1383 3.04 2837 1455 3.28 3061 ---- ---- ---- ---- 1267 2.55 2377 1351 2.86 2663 1423 3.10 2887 1494 3.31 3085 ---- ---- 1240 2.39 2231 1306 2.59 2411 1392 2.92 2720 1462 3.13 2917 1533 3.31 3086 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1213 2.24 2090 1279 2.44 2270 1361 2.74 2558 1432 2.96 2755 1502 3.14 2924 1574 3.29 3062 1648 3.40 3169 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1186 2.10 1955 1253 2.29 2135 1318 2.46 2291 1402 2.79 2600 1472 2.97 2768 1544 3.12 2907 1619 3.23 3013 1698 3.31 3087 1160 1.96 1826 1227 2.15 2006 1292 2.32 2161 1373 2.63 2450 1443 2.81 2619 1515 2.96 2757 1590 3.07 2864 1669 3.15 2937 1135 1.83 1702 1201 2.02 1882 1266 2.19 2038 1345 2.47 2307 1415 2.66 2475 1487 2.80 2614 1561 2.92 2721 1641 3.00 2794 1110 1.70 1584 1177 1.89 1764 1241 2.06 1920 1307 2.21 2062 1388 2.51 2338 1460 2.66 2477 1534 2.77 2583 1613 2.85 2657 1086 1.58 1471 1152 1.77 1651 1217 1.94 1807 1283 2.09 1949 1362 2.37 2207 1434 2.52 2346 1508 2.63 2452 1587 2.71 2526 1062 1.46 1364 1129 1.66 1544 1194 1.82 1700 1259 1.98 1842 1328 2.13 1981 1408 2.38 2221 1483 2.50 2328 1562 2.58 2401 1040 1.35 1261 1106 1.55 1441 1171 1.71 1597 1236 1.87 1739 1305 2.02 1878 1384 2.26 2102 1459 2.37 2209 1538 2.45 2282 1018 1.25 1164 1085 1.44 1344 1149 1.61 1499 1215 1.76 1641 1283 1.91 1780 1362 2.13 1990 1436 2.25 2096 1515 2.33 2170 997 978 959 942 927 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 2000 842 0.46 431 913 0.69 647 980 0.89 827 1044 1.05 982 1110 1.21 1124 1178 1.36 1263 1253 1.51 1411 1335 1.69 1577 1429 1.90 1773 CFM TABLE 28: DM102 (8-1/2 TON) DOWN SHOT BLOWER PERFORMANCE 246645-YTG-C-0708 Johnson Controls Unitary Products 0.2 0.4 0.6 0.8 1.0 External Static Pressure 1.2 1.4 1.6 Johnson Controls Unitary Products 2760 2934 3115 3305 2.16 2.30 2.45 2.61 2.78 2.96 900 919 938 957 976 995 4300 4400 4500 4600 4700 4800 1015 3.15 4900 1034 3.34 5000 1053 3.55 Std HP Motor 2 Motor Efficiency 0.8 988 2.56 2383 1026 2.76 2571 1058 2.95 2749 2.80 2614 1032 3.00 2792 1063 3.18 2963 ------- 1065 3.52 3278 1082 3.71 3462 ---- ------- ---- 1047 3.33 3102 1075 3.49 3253 1030 3.15 2932 1061 3.32 3094 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2.65 2466 1017 2.84 2650 1050 3.03 2828 1079 3.21 2996 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 974 2.42 2257 1014 2.63 2449 1048 2.82 2631 1076 3.00 2797 ---- ---- 959 2.29 2138 1002 2.50 2331 1038 2.70 2516 1067 2.88 2686 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 990 2.38 2218 1027 2.58 2405 1059 2.77 2578 945 2.17 2023 ---- ---- 977 2.26 2109 1017 2.46 2297 1050 2.65 2473 1076 2.81 2621 930 2.05 1915 ---- ---- 965 2.15 2005 1007 2.35 2193 1041 2.54 2370 1069 2.71 2522 916 1.94 1812 953 2.04 1905 941 1.94 1810 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 976 2.04 1902 1015 2.23 2080 1047 2.40 2239 1072 2.53 2361 ---- 887 1.74 1623 901 1.84 1715 1013 2.97 2770 1046 3.15 2940 1075 3.33 3103 996 979 998 2.04 1900 1032 2.21 2061 1060 2.35 2190 990 1.95 1815 1025 2.12 1976 1053 2.26 2107 981 1.86 1732 1018 2.03 1893 1047 2.17 2026 966 1.94 1812 1007 2.13 1989 1040 2.31 2149 1066 2.44 2275 956 1.85 1726 945 1.76 1643 935 1.68 1564 986 2.14 1995 1024 2.33 2174 1054 2.50 2331 929 1.84 1719 916 1.75 1632 904 1.66 1550 892 1.58 1473 880 1.50 1400 997 2.24 2092 1033 2.44 2270 1062 2.60 2425 872 1.65 1537 858 1.56 1456 843 1.48 1381 829 1.41 1312 814 1.34 1248 2.49 2324 1003 2.70 2514 1038 2.89 2697 1068 3.08 2871 2.35 2190 945 962 2.21 2063 2.08 1943 1.96 1829 1.85 1723 1.74 1624 1.64 1532 1.55 1447 1.47 1369 1.39 1298 1.32 1234 1.26 1178 1.21 1128 928 911 894 877 860 843 826 809 792 775 758 741 High Horsepower Option Required 2595 2437 2288 2148 2015 1890 1774 1666 4200 2.03 1.90 1.79 1566 862 843 3900 1.68 1474 881 824 3800 1.58 1391 1315 1248 ---- ---- ---- ---- 4100 805 3700 1.49 1.41 1.34 ---- ---- ---- ---- 4000 767 786 3500 3600 ---- 748 ---- 3200 3400 ---- 3300 ---- 3100 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 3000 CFM TABLE 29: DM120 (10 TON) DOWN SHOT BLOWER PERFORMANCE 246645-YTG-C-0708 31 32 0.2 3971 4166 4368 4576 4792 ---- 5500 1141 4.26 5600 1160 4.47 5700 1178 4.69 5800 1197 4.91 5900 1216 5.14 ---- ---- 6000 6100 0.6 0.8 1.0 1.2 External Static Pressure 1.4 1.6 1.8 2.0 ---- ---- ---- ---- Std HP Motor 3 Motor Efficiency 0.8 ---- ---- 908 1.99 1853 957 2.12 1976 1004 2.27 2112 1050 2.42 2258 1094 2.59 2412 1136 2.76 2571 1177 2.93 2733 1217 3.11 2895 2.16 2012 960 2.30 2147 1007 2.46 2294 1052 2.63 2449 1096 2.80 2611 1138 2.98 2777 1179 3.16 2945 1219 3.34 3113 1258 3.52 3280 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1234 5.12 4776 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1216 4.90 4569 1253 5.11 4765 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1198 4.69 4369 1235 4.90 4566 1271 5.10 4756 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1180 4.48 4175 1218 4.69 4373 1255 4.90 4564 1291 5.10 4750 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1162 4.28 3987 1201 4.49 4185 1238 4.70 4378 1275 4.90 4565 1311 5.09 4745 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1144 4.08 3805 1184 4.29 4003 1222 4.50 4196 1259 4.70 4384 1296 4.90 4566 1331 5.09 4742 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1126 3.89 3629 1167 4.11 3827 1205 4.31 4020 1243 4.51 4208 1281 4.71 4391 1317 4.90 4569 1352 5.09 4740 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1108 3.71 3460 1149 3.92 3656 1189 4.13 3848 1227 4.33 4037 1265 4.53 4221 1302 4.72 4399 1338 4.91 4572 1372 5.09 4740 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1090 3.54 3297 1132 3.74 3491 1172 3.95 3682 1211 4.15 3870 1250 4.35 4054 1287 4.54 4233 1323 4.73 4407 1358 4.91 4577 1392 5.09 4744 1072 3.37 3141 1115 3.57 3331 1156 3.78 3520 1196 3.98 3707 1234 4.17 3891 1272 4.37 4071 1309 4.56 4246 1344 4.74 4417 1379 4.92 4585 1054 3.21 2990 1098 3.41 3177 1139 3.61 3364 1180 3.81 3549 1219 4.00 3732 1257 4.20 3912 1294 4.39 4088 1330 4.57 4260 1365 4.75 4429 1036 3.05 2846 1081 3.25 3029 1123 3.45 3212 1164 3.64 3396 1204 3.84 3578 1242 4.03 3758 1280 4.22 3933 1316 4.40 4106 1352 4.59 4275 1019 2.91 2708 1063 3.10 2886 1106 3.29 3066 1148 3.48 3247 1188 3.68 3428 1227 3.87 3606 1266 4.06 3782 1303 4.24 3955 1338 4.43 4125 1001 2.76 2577 1046 2.95 2749 1090 3.14 2925 1132 3.33 3103 1173 3.52 3281 1212 3.71 3459 1251 3.90 3634 1289 4.08 3807 1325 4.27 3977 983 2.63 2451 1029 2.81 2617 1073 2.99 2788 1116 3.18 2963 1157 3.37 3139 1198 3.56 3315 1237 3.74 3490 1275 3.93 3662 1311 4.11 3832 965 2.50 2332 1012 2.67 2491 1056 2.85 2657 1100 3.03 2828 1142 3.22 3001 1183 3.41 3175 1223 3.59 3348 1261 3.78 3520 1298 3.96 3690 947 2.38 2219 995 2.54 2371 1040 2.72 2531 1084 2.89 2697 1127 3.08 2867 1168 3.26 3039 1208 3.44 3211 1247 3.63 3381 1285 3.81 3550 929 2.27 2113 977 2.42 2256 1023 2.59 2410 1068 2.76 2571 1111 2.94 2737 1153 3.12 2906 1194 3.30 3076 1233 3.48 3245 1271 3.66 3414 911 893 2.06 1918 943 2.19 2044 990 2.34 2183 1036 2.50 2332 1080 2.67 2489 1123 2.84 2652 1165 3.02 2817 1205 3.20 2983 1244 3.38 3149 875 1.96 1831 926 2.09 1946 974 2.23 2077 1020 2.38 2220 1065 2.54 2372 1108 2.71 2530 1151 2.89 2693 1191 3.06 2856 1231 3.24 3021 High Horsepower Option Required ---- 3784 5400 1122 4.06 ---- 3603 5300 1103 3.87 ---- 3430 2536 5200 1084 3.68 2.72 3263 991 4700 2411 5100 1066 3.50 972 4600 2.59 2294 3103 953 4500 2.46 2184 2080 2951 934 4400 2.34 2.23 5000 1047 3.33 915 4300 1984 4900 1028 3.17 897 4200 2.13 ---- ---- 2806 878 4100 ---- ---- 4800 1009 3.01 ---- 4000 ---- ---- 2667 ---- 3900 ---- ---- 2.86 ---- ---- 3800 6200 0.4 RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts 3700 CFM TABLE 30: DM150 (12-1/2 TON) DOWN SHOT BLOWER PERFORMANCE 246645-YTG-C-0708 Johnson Controls Unitary Products 246645-YTG-C-0708 TABLE 31: ADDITIONAL STATIC RESISTANCE DM078, 120 AND 150 CFM Cooling Only* Electric Heat KW† Economizer† ‡ 9 18 24 36 54 0.10 1900 0.06 0.02 0.05 0.06 0.07 0.08 2100 0.07 0.02 0.06 0.07 0.08 0.09 0.11 2300 0.08 0.02 0.07 0.08 0.09 0.10 0.13 2500 0.09 0.02 0.08 0.09 0.10 0.11 0.14 2700 0.11 0.03 0.09 0.10 0.12 0.13 0.16 2900 0.12 0.03 0.10 0.11 0.13 0.14 0.18 3100 0.14 0.03 0.12 0.13 0.15 0.16 0.20 3300 0.16 0.03 0.13 0.14 0.17 0.18 0.22 3500 0.18 0.04 0.15 0.16 0.19 0.20 0.24 3700 0.20 0.04 0.17 0.18 0.21 0.22 0.26 3900 0.23 0.04 0.19 0.20 0.23 0.24 0.28 4100 0.25 0.04 0.21 0.22 0.25 0.26 0.31 4300 0.28 0.05 0.23 0.24 0.28 0.29 0.34 4500 0.30 0.05 0.25 0.26 0.30 0.31 0.37 4700 0.33 0.05 0.28 0.29 0.33 0.34 0.40 4900 0.36 0.05 0.30 0.31 0.35 0.37 0.43 5100 0.39 0.06 0.33 0.34 0.38 0.40 0.46 5300 0.42 0.06 0.35 0.37 0.41 0.43 0.49 5500 0.45 0.06 0.38 0.40 0.44 0.46 0.53 5700 0.48 0.06 0.41 0.43 0.47 0.49 0.56 5900 0.52 0.07 0.44 0.46 0.50 0.53 0.59 6100 0.56 0.07 0.47 0.49 0.53 0.56 0.62 6300 0.60 0.07 0.50 0.53 0.56 0.59 0.65 * Add these resistance values to the available static resistance in the respective Blower Performance Tables. † Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table. ‡ The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. TABLE 32: ADDITIONAL STATIC RESISTANCE DM090, 102 CFM 1900 2100 2300 2500 2700 2900 3100 3300 3500 3700 3900 4100 4300 Cooling Only* Economizer† ‡ -0.004 0.01 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.09 0.10 0.07 0.09 0.11 0.13 0.16 0.18 0.20 0.22 0.24 0.27 0.29 0.31 0.33 Electric Heat KW† 9 18 24 36 54 0.05 0.06 0.07 0.08 0.09 0.1 0.12 0.13 0.15 0.17 0.19 0.21 0.23 0.06 0.07 0.08 0.09 0.1 0.11 0.13 0.14 0.16 0.18 0.2 0.22 0.24 0.07 0.08 0.09 0.1 0.12 0.13 0.15 0.17 0.19 0.21 0.23 0.25 0.28 0.08 0.09 0.1 0.11 0.13 0.14 0.16 0.18 0.2 0.22 0.24 0.26 0.29 0.1 0.11 0.13 0.14 0.16 0.18 0.2 0.22 0.24 0.26 0.28 0.31 0.34 * Deduct these resistance values to the available static resistance in the respective Blower Performance Tables. † Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table. ‡ The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. Johnson Controls Unitary Products 33 246645-YTG-C-0708 TABLE 33: ELECTRIC HEAT MINIMUM SUPPLY AIR CFM UNIT MODEL SIZE (NOMINAL TONS) HEATER 078 (6.5) VOLTAGE kW 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) MINIMUM SUPPLY AIR CFM 9 1950 2250 2550 N/A N/A 18 1950 2250 2550 3000 3750 1950 2250 2550 3000 3750 1950 2250 2550 3000 3750 4000 208/230 24 36 54 N/A N/A N/A 3500 9 1950 2250 2550 N/A N/A 18 1950 2250 2550 3000 3750 1950 2250 2550 3000 3750 36 1950 2250 2550 3000 3750 54 N/A N/A N/A 3000 3750 9 1950 2250 2550 N/A N/A 18 1950 2250 2550 3000 3750 480 24 1950 2250 2550 3000 3750 36 1950 2250 2550 3000 3750 54 N/A N/A N/A 3500 3750 600 24 TABLE 34: INDOOR BLOWER SPECIFICATIONS MODEL DM078 DM090 DM102 DM120 DM150 MOTOR MOTOR SHEAVE BLOWER SHEAVE BELT HP RPM Eff. SF Frame Datum Dia. (in.) Bore (in.) Model Datum Dia. (in.) Bore (in.) Model 1-1/2 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 9.5 1 AK99 A58 2 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 7.5 1 AK79 A55 2 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 6.5 1 AK69 A49 3 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 6.0 1 AK64 A49 3 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 6.0 1 AK64 A49 3 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 5.7 1 AK61 A49 2 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 8.5 1 AK89 A56 3 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 7.0 1 AK74 A54 3 1725 80% 1.15 56 3.4 - 4.4 7/8 1VM50 7.0 1 AK74 A54 5 1725 87% 1.15 184T 4.3 - 5.3 1 1/8 1VP56 6.7 1 BK77 BX55 TABLE 35: POWER EXHAUST SPECIFICATIONS POWER EXHAUST MODEL VOLT PHASE 2PE0473225 2PE0473246 2PE0473258 208/230 460 575 1 1 1 * 34 MOTOR HP 0.75 RPM* 1075 1050 ELECTRICAL QTY 1 LRA FLA MCA FUSE SIZE CFM@ 0.1 ESP 24.9 5.0 2.2 1.5 6.3 2.8 1.9 10 5 4 3,800 N/A Motors are multi-tapped and factory wired for high speed. Johnson Controls Unitary Products 246645-YTG-C-0708 Y X FRONT LEFT Unit Model Number X Y DM078 47 1/2 25 1/2 DM090 38 23 DM102 38 23 DM120 47 1/2 25 1/2 DM150 47 1/2 25 1/2 F R O N T L E F T B C A FIGURE 3 D FIGURE 2 - UNIT CENTER OF GRAVITY UNIT 4 POINT LOAD TABLE 36: 4 POINT LOAD WEIGHT Location (lbs.) Model A B C D DM078 228 195 285 333 DM090 192 143 224 301 DM102 195 146 228 306 DM120 245 209 305 357 DM150 262 224 327 382 F R O N T L E F T A D C B E F FIGURE 4 - Johnson Controls Unitary Products UNIT 6 POINT LOAD 35 246645-YTG-C-0708 TABLE 37: 6 POINT LOAD WEIGHT TABLE 38: UNIT WEIGHT Locations (lbs.) Model A B C D E F DM078 156 140 127 185 205 228 DM090 135 110 91 142 172 211 DM102 137 112 93 145 145 214 DM120 168 151 136 198 219 244 DM150 180 161 145 212 235 262 Model Shipping Weight (lbs.) Operating Weight (lbs.) DM078 1046 1041 DM090 865 860 DM102 880 875 DM120 1121 1116 DM150 1200 1195 30-11/32 X Power Entry Ø 2-1/2 See Detail A Control Entry Ø 7/8 Power Entry Ø 2-1/2 4-1/4 11-1/2 Convenience Power Outlet Entry Ø 7/8 30-3/16 59 17-3/16 89 27 UNIT DIMENSIONS TABLE 40: UNIT CLEARANCES TABLE 39: UNIT HEIGHT Unit Model Number X Top* 72” Right 12” DM078 50 3/4 Front 36” Left 36” DM090 42 Rear† 36” Bottom‡ 0” DM102 42 DM120 50 3/4 DM150 50 3/4 G a s P ip e In le t DETAIL A 5 -1 /4 V ie w o f W a ll A c r o s s fr o m * Units must be installed outdoors. Overhanging structure or shrubs should not obstruct condenser air discharge outlet. † To remove the slide-out drain pan, a rear clearance of 60” is required. If space is unavailable, the drain pan can be removed through the front by separating the corner wall. ‡ Units may be installed on combustible floors made from wood or class A, B or C roof covering materials. B a s e P a n 1 7 -1 3 /1 6 36 For Baserail Dimensions See Detail B For Drain Dimensions See Detail C 6-3/16 24-3/16 LEFT FIGURE 5 - FRONT C o il Johnson Controls Unitary Products 246645-YTG-C-0708 DETAIL C DETAIL B 2-3/8 5 -3 /8 3-3/4 3-9/16 R IG H T 8 0 -5 /8 IN S U L A T E D D E C K U N D E R C O N D E N S E R S E C T IO N 2 0 2 0 S U P P L Y 6 R E T U R N 2 T Y P . 3 0 IN S U L A T E D D E C K U N D E R C O M P R E S S O R S E C T IO N 5 0 -1 /2 8 o r 1 4 FIGURE 6 - F R O N T PREDATOR® ROOF CURB DIMENSIONS Johnson Controls Unitary Products 37 246645-YTG-C-0708 2 T Y P 2 3 3 0 -1 /2 5 0 -1 /2 4 8 0 -5 /8 2 6 R E T U R N S U P P L Y 1 0 7 6 -5 /8 5 9 -1 /4 9 4 F R O N T FIGURE 7 - 6 4 -1 /4 R IG H T SUNLINE™ TO PREDATOR® TRANSITION ROOF CURBS 32-11/16 6-13/16 Supply Air 6-13/16 6-13/16 Return Air 24 LEFT 27-1/2 21 18 21-3/16 19-3/16 17-3/16 12-5/16 7-1/8 14-23/32 FRONT 16-3/8 18-1/16 19-5/8 Bottom Condensate Drain Bottom Power, Control and Convenience Outlet Wiring Entries Bottom Gas Supply Entry 63-1/2 FIGURE 8 - 38 BOTTOM DUCT OPENINGS (FROM ABOVE) Johnson Controls Unitary Products 246645-YTG-C-0708 18-1/4 Dot Plugs REAR DUCT DIMENSIONS DIMENSION CABINET SIZE “A” “B” “C” 50 3/4” 28 1/4 18 1/16 28 1/4 42” 27 3/4 12 1/16 27 1/2 Supply Air Return Air A 18-1/4 B 2-31/32 5-5/32 FIGURE 9 - C 31-11/16 REAR DUCT DIMENSIONS 58 1/4 88 1/4 39 1/2 or 47 1/2 Outside Air Intake Hood 35 3/4 Relief Hood for Power Exhaust or Barometric Relief 26 25 3/4 26 30 1/4 FIGURE 10 - DOWNFLOW ECONOMIZER HOOD DETAIL Johnson Controls Unitary Products 39 246645-YTG-C-0708 TABLE 41: ECONOMIZER USAGE Application Cabinet Height Description Model Bottom Return All Downflow economizer with barometric relief 2EE04705424 Side Return All Horizontal economizer without barometric relief 2EE04705524* 42" Slab Economizer, 42” tall cabinet 2EE04705624† 50" Slab Economizer, 50” tall cabinet 2EE04705224† ERV or End Return * Barometric relief must be ordered separately and installed in duct work. † Barometric relief or fresh air hood not included. Must be ordered separately. 2EE04705424 Fresh Air Hood 2EE04705424 2EE04705424 2EE04705424 Fresh Air Damper Return Air Damper Barometric Relief Damper 2EE04705424 Barometric Relief Hood FIGURE 11 - FACTORY INSTALLED DOWNFLOW ECONOMIZER 2EE04705424 Fresh Air Hood 2EE04705424 2EE04705424 Fresh Air Damper Return Air Damper 2PE047032XX Power Exhaust 2EE04705424 Barometric Relief Damper 2EE04705424 Barometric Relief Hood FIGURE 12 - FIELD INSTALLED DOWNFLOW ECONOMIZER W/POWER EXHAUST 40 Johnson Controls Unitary Products 246645-YTG-C-0708 2EE04705524 Return Air Damper Field Installed Duct Work 2EE04705524 Fresh Air Damper 2PE047032XX Power Exhaust 1EH0408 Barometric Relief Damper 1EH0408 Barometric Relief Hood 2EE04705524 Fresh Air Hood FIGURE 13 - FIELD INSTALLED HORIZONTAL ECONOMIZER W/POWER EXHAUST 1EH0409 Fresh Air Hood 2EE04705X24 Slab Economizer 2PE047032XX Power Exhaust 1EH0409 Barometric Relief Damper 1EH0409 Barometric Relief Hood FIGURE 14 - SLAB ECONOMIZER DOWNFLOW W/POWER EXHAUST Johnson Controls Unitary Products 41 246645-YTG-C-0708 1EH0409 Fresh Air Hood Field Installed Duct Work 2EE04705X24 Slab Economizer 1EH0409 Barometric Relief Hood 1EH0409 Barometric Relief Damper 2PE047032XX Power Exhaust FIGURE 15 - SLAB ECONOMIZER END RETURN W/POWER EXHAUST 42 Johnson Controls Unitary Products 246645-YTG-C-0708 FIGURE 16 - COOLING UNIT WITH GAS HEAT WIRING 230 VOLT DIAGRAM Johnson Controls Unitary Products 43 246645-YTG-C-0708 FIGURE 17 - COOLING UNIT WITH/WITHOUT ELECTRIC HEAT WIRING DIAGRAM 44 Johnson Controls Unitary Products 246645-YTG-C-0708 FIGURE 18 - COOLING UNIT WITH GAS HEAT WIRING 460, 575 VOLT AND 50 HZ DIAGRAM Johnson Controls Unitary Products 45 246645-YTG-C-0708 GUIDE SPECIFICATIONS PREDATOR® DM 078, 090, 102, 120 & 150 9.0 EER GENERAL Units shall be manufactured by York International Unitary Products Group in an ISO 9001 certified facility. YORK® Predator® units are convertible single packages with a common footprint cabinet and common roof curb for all 6-1/2 through 12-1/2 ton models. All units have two compressors with independent refrigeration circuits to provide 2 stages of cooling. The units were designed for light commercial applications and can be easily installed on a roof curb, slab, or frame. All Predator® units are self-contained and assembled on rigid full perimeter base rails allowing for 3-way forklift access and overhead rigging. Every unit is completely charged, wired, piped, and tested at the factory to provide a quick and easy field installation. All units are convertible between side and down airflow. Independent economizer designs are used on side and down discharge applications, as well as all tonnage sizes. Predator® units are available in the following configurations: cooling only, cooling with electric heat, and cooling with gas heat. Electric heaters are available as factory-installed options and field-installed accessories. fan performance without removing panels or creating bypass of the coils. Condensate pan shall be slide out design, constructed of a non corrosive material, internally sloped and conforming to ASHRAE 62-B9 standards. Condensate connection shall be a minimum of ¾” I.D. female and be rigid mount connection. DESCRIPTION OUTDOOR (CONDENSER) FAN ASSEMBLY Units shall be factory assembled, single package, (Elec/Elec, Gas/Elec), designed for outdoor installation. Units shall have a minimum EER of 9.0. They shall have built in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return and be available with factory installed options or field installed accessories. The units shall be factory wired, piped and charged with R-22 refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. The cooling performance shall be rated in accordance with DOE and ARI test procedures. Units shall be CSA certified to ANSI Z21.47 and UL 1995/CAN/CSA No. 236-M90 standards. The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider brackets and shall be dynamically balanced for smooth operation. The outdoor fan motors shall have permanently lubricated bearings internally protected against overload conditions and staged independently. A cleaning window shall be provided on two sides of the units for coil cleaning. UNIT CABINET Unit cabinet shall be constructed of G90 galvanized steel with exterior surfaces coated with a non-chalking, powder paint finish, certified at 1000 hours salt spray test per ASTM-B117 standards. Indoor blower sections shall be insulated with up to 1” thick insulation coated on the airside. Aluminum foil faced insulation shall be used in the unit’s compartments and be fastened to prevent insulation from entering the air stream. Cabinet doors shall be hinged with tool-less access for easy servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, fork truck access and proper sealing on roof curb applications. Disposable 2” filters shall be furnished and be accessible through hinged access door. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator 46 INDOOR (EVAPORATOR) FAN ASSEMBLY Fan shall be a belt drive assembly and include an adjustable pitch motor pulley. Job site selected brake horsepower shall not exceed the motors nameplate horsepower rating plus the service factor. Units shall be designed to operate within the service factor. Fan wheel shall be double inlet type with forward curve blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Entire blower assembly and motor shall be slide out design. REFRIGERANT COMPONENTS Compressors: A. Shall be fully hermetic type, direct drive, internally protected with internal high-pressure relief and over temperature protection. The hermetic motor shall be suction gas cooled and have a voltage range of + or – 10% of the unit nameplate voltage. B. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: A. Evaporator and condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. B. Evaporator and condenser coils shall be of the direct expansion, draw-thru design. Johnson Controls Unitary Products 246645-YTG-C-0708 Refrigerant Circuit and Refrigerant Safety Components shall include: A. Independent fixed-orifice or thermally operated expansion devices. B. Solid core filter drier/strainer to eliminate any moisture or foreign matter. C. Accessible service gage connections on both suction and discharge lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. D. The unit shall have two independent refrigerant circuits, equally split in 50% capacity increments. Unit Controls: A. Unit shall be complete with self-contained low-voltage control circuit protected by a resettable circuit breaker on the 24-volt transformer side. B. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit should any of the following standard safety devices trip and shut off compressor: C. Loss-of-charge/Low-pressure switch. (1) High-pressure switch. (2) Freeze-protection thermostat, evaporator coil. If any of the above safety devices trip, an LED (light-emitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. D. Unit shall incorporate “AUTO RESET” compressor over temperature, over current protection. E. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. F. Unit control board shall have on-board diagnostics and fault code display. G. Standard controls shall include anti-short cycle and low voltage protection, and permit cooling operation down to 0 ºF. H. Control board shall monitor each refrigerant safety switch independently. I. Control board shall retain last 5 fault codes in non-volatile memory, which will not be lost in the event of a power loss. GAS HEATING SECTION (IF EQUIPPED) Heat exchanger and exhaust system shall be constructed of aluminized steel and shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. The heat exchanger shall be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 40 ºF. Burners shall be of the in- Johnson Controls Unitary Products shot type, constructed of aluminum-coated steel. All gas piping shall enter the unit cabinet at a single location, through either the side or bottom, without any field modifications. An integrated control board shall provide timed control of evaporator fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: A. Primary and auxiliary high-temperature limit switches. B. Induced draft pressure sensor. C. Flame roll out switch (manual reset). D. Flame proving controls. Unit shall have two independent stages of capacity (60% 1st stage, 100% 2nd stage). ELECTRIC HEATING SECTION (IF EQUIPPED) An electric heating section, with nickel chromium elements, shall be provided in a range of 9 thru 54 KW, offering two states of capacity all sizes. The heating section shall have a primary limit control(s) (automatic reset) to prevent the heating element system from operating at an excessive temperature. The Heating Section assembly shall slide out of the unit for easy maintenance and service. Units with Electric Heating Sections shall be wired for a single point power supply with branch circuit fusing (where required). UNIT OPERATING CHARACTERISTICS Unit shall be capable of starting and running at 125 ºF outdoor temperature, exceeding maximum load criteria of ARI Standard 340/360. The compressor, with standard controls, shall be capable of operation down to 0 ºF outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up. (Gas heat only) ELECTRICAL REQUIREMENTS - All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES - Compressor – 5 Years, Heat Exchanger – 10 Years, Elect. Heat Elem. – 5 Years, Parts – 1 Year FACTORY INSTALLED OPTIONAL OUTDOOR AIR (Shall be made available by either/or): 1. ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER – Outdoor and return air dampers that are interlocked and positioned by a fully-modulating, springreturn damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in outdoor air to meet the minimum ventilation requirement of the conditioned space during normal operation. During economizer operation, a mixed-air temperature control shall modulate the 47 outdoor and return air damper assembly to prevent the supply air temperature from dropping below 55 ºF. Changeover from compressor to economizer operation shall be provided by an integral electronic enthalpy control that feeds input into the basic module. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. Available with barometric relief or power exhaust. 2. MOTORIZED OUTDOOR AIR DAMPERS – Outdoor and return air dampers that are interlocked and positioned by a 2-position, spring-return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in the design CFM of outdoor air to meet the ventilation requirements of the conditioned space during normal operation. Whenever the indoor fan motor is energized, the dampers open up to one of two pre-selected positions – regardless of the outdoor air enthalpy. Dampers return to the fully closed position when the indoor fan motor is de-energized. Dampers shall fully close on power loss. • COIL GUARD - Designed to prevent condenser coil damage. • BAS CONTROLS - Include supply air sensor, return air sensor, dirty filter indicator and air proving switch. • DIRTY FILTER SWITCH – This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally highpressure drop across the filters. • BREAKER – An HACR breaker can be factory installed on gas heat units or cooling units with electric heat. • DISCONNECT SWITCH - A disconnect can be factory installed on a cooling only units sized for the largest electric heat available. • STAINLESS STEEL HEAT EXCHANGER – For applications in a corrosive environment, this option provides a full stainless steel heat exchanger assembly. • STAINLESS STEEL DRAIN PAN – Provides years of trouble-free operation in corrosive environments. • SMOKE DETECTOR – A smoke detector can be factory mounted and wired in the supply and/or return air compartments. OTHER PRE-ENGINEERED ACCESSORIES AVAILABLE • ROOF CURB - 14” and 8” high, full perimeter knockdown curb, with hinged design for quick assembly. • BAROMETRIC RELIEF DAMPER – (Unit mounted – Downflow, Duct Mounted – Horizontal) – Contains a rain hood, air inlet screen, exhaust damper and mounting hardware. Used to relieve internal air pressure through the unit during economizer operation. • PROPANE CONVERSION KIT – Contains new orifices and gas valve springs to convert from natural to L.P. gas. • –60 ºF GAS HEAT KIT – Provides an electric heat kit for the gas compartment for use in extreme low ambient conditions. • ECONOMIZER (Downflow and Horizontal flow) • POWER EXHAUST – (Unit mount – Downflow, Duct mount – Horizontal flow) • DUAL ENTHALPY KIT - Provides a second input to economizer to monitor return air. ADDITIONAL FACTORY INSTALLED OPTIONS • ALTERNATE INDOOR BLOWER MOTOR – For applications with high restrictions, units are available with optional indoor blower motors that provide higher static output and/or higher airflow. • CONVENIENCE OUTLET (POWERED/NON-POWERED) – Unit can be provided with an optional 120VAC GFCI outlet with cover on the corner of the unit housing the compressors. • • ELECTRIC HEAT - Electric heaters range from 9 kW to 54 kW and are available in all the voltage options of the base unit. PHASE MONITOR - Designed to prevent damage in outof-phase condition. Subject to change without notice. Printed in U.S.A. Copyright © 2008 by Johnson Controls, Inc. All rights reserved. Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069 246645-YTG-C-0708 Supersedes: 246645-YTG-B-0606
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Mode : UseThumbs XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : FrameMaker 8.0 Modify Date : 2008:08:28 10:52:54-05:00 Create Date : 1999:12:07 10:08:53Z Metadata Date : 2008:08:28 10:52:54-05:00 Format : application/pdf Title : Y-TG, Predator Std. Eff. Sgl Pkg AC and Sgl Pkg Gas/Elec Units, Models: DM078, 090, 102, 120 and 150 Creator : . Document ID : uuid:cd2b267f-44a8-48db-a88c-ce8991356eef Instance ID : uuid:53eb1c45-25e0-45fe-9485-d57b8e6fcea2 Page Count : 48 Page Layout : OneColumn Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools