York Sunline 2000 D3Ce Users Manual
D3CG to the manual f4999665-edb6-483a-a04d-ba41ef143738
2015-02-02
: York Sunline-2000-D3Ce-Users-Manual york-sunline-2000-d3ce-users-manual-455158 york pdf
Open the PDF directly: View PDF .
Page Count: 20
Download | |
Open PDF In Browser | View PDF |
530.26-TG3YI (1294) ® SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D3CE / D3CG 180 & 240 (WORLD 50 HZ) DCG Shown SUNLINE 2000 DESCRIPTION Sunline 2000 units are highly efficient, convertible rooftops. All models have dual refrigerant circuits for efficient part load operation. Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof. These units are designed and manufactured under ISO 9002 Quality System Certification. Cooling only, cooling with gas heat and cooling with supplemental electric heat units are available with a wide variety of field-installed accessories to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails. The base rails have holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. Powder paint cabinets provide an exceptionally durable finish with the 750 hour salt spray process per ASTM-B117 test standard. All models are available with three different outdoor air damper accessosries: • Single enthalpy economizer • Differential enthalpy economizer • Motorized outdoor air intake damper All models (including those with an economizer ) are suitable for either downflow or sideflow duct connections. For downflow duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For sideflow duct, replace the supply and return air panels on the rear of the unit with a side duct flange accessory. A fixed outdoor air intake assembly is shipped in the return air compartment of all units. The assembly includes a rain hood with a damper that can be set for 10, 15 or 25% outdoor air. With bottom duct connections, the intake damper assembly should be mounted over the opening in the return air panel. With horizontal ductwork, it should be mounted on the return air duct. All supply air blowers are equipped with a belt drive that can be adjusted to meet the exact requirements of the job. All compressors include crankcase heat and internal pressure relief. Every refrigerant circuit includes an expansion valve, a liquid line filter-drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure switch. The unit control circuit includes a 75 VA transformer, a 24-volt circuit breaker and a relay board with two compressor lockout circuits, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All gas heat models are built with two heating sections for two equal stages of capacity control. Each section includes a durable heat exchanger with aluminized steel tubes, a redundant gas valve, spark ignition, power venting, an ignition module for 100% shut-off and all of the safety controls required to meet the latest ANSI standards. The gas supply piping can be routed into the heating compartment through a hole in the base pan of the unit or through a knockout in the piping panel on the front of the unit. All electric heat models are wired for a single power source and include a bank of nickel chromium elements mounted at the discharge of the supply air blower to provide a high velocity and uniform distribution of air across the heating elements. Every element is fully protected against excessive current and temperature by fuses and two thermal limit switches. The power supply wiring can be routed into the control box through a threaded pipe connection in the base pan of the unit or through a knockout in the wiring panel on the front of the unit. 530.26-TG3YI FIELD-INSTALLED ACCESSORIES On units built prior to January 1995 an accessory field harness must be installled. SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZERS Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. Power exhaust is not available as a field installed option. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide “free” cooling. The rain hood is painted to match the basic unit and must be field-assembled before installing. On units built prior to January 1995 an accessory field harness must be installed. Power exhaust is not available as a field installed option. DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZERS Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. This enthalpy system contains one sensor that monitors the outdoor air and one sensor that monitors the return air. The logic module compares the two values and modulates the dampers, providing the maximum efficiency of the economizer system. The rain hood is painted to match the basic unit and must be field-assembled before installing. On units built prior to January 1995 an accessory field harness must be installed. Power exhaust is not available as a field installed option. MOTORIZED OUTDOOR AIR INTAKE DAMPER - Includes a slide-in / plug-in damper with a 2-position, spring-return motor actuator which opens to a pre-set position whenever the supply air blower is operating and drives fully closed when the blower shuts down. BAROMETRIC RELIEF DAMPER - This damper accessory can be used to relieve internal air pressure on units with an economizer. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. ROOF CURBS - Roof curbs, 356mm (14 in.) high, provide a water-tight seal between the unit and the finished roof. These full perimeter curbs meet the requirements of the National Roofing Contractors Association (NRCA) and are shipped knocked-down for field assembly. They’re designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger supports. SIDE DUCT FLANGES - Twenty-five millimeter (1 in.) flanges replace the supply and return air panels on the rear of the unit to accommodate horizontal duct connections. These flanges can also be used individually for bottom supply/horizontal return or horizontal supply/bottom return. HIGH SPEED DRIVE - A smaller blower pulley, a larger motor pulley (including a replacement belt) increase the speed of the supply air blower for applications with a higher airflow and/or static pressure requirement. ANTI-RECYCLE TIMERS - Two solid state timers prevent the compressors from short-cycling. Once a compressor is de-energized, it remains de-energized for approximately five minutes. LOW AMBIENT CONTROLS TO 18°C (0°F) - An autotransformer and a thermostat maintain stable system operation by reducing the speed of the #1 condenser fan motor at low oudoor temperatures. The kit also includes a 1-phase motor to replace the unit’s standard 3-phase condenser fan motor. Standard units can operate down to 4 °C (25 °F). TABLE OF CONTENTS Description ...........................................................................1 Field-Installed Accessories...................................................2 Ratings .................................................................................3 Cooling Capacities ...............................................................4 Blower Performance.............................................................8 Blower Motor and Drive Data ............................................. 12 Static Resistances................. .............................................10 Field Wiring ........................................................................ 13 2 Electrical Data - Cooling and Gas Heat ............................. 13 Electrical Data - Units with Electric Heat............................ 14 Physical Data ..................................................................... 14 Unit Dimensions ................................................................. 15 Roof Curb Dimensions ....................................................... 18 Typical Applications ............................................................ 18 Unitary Products Group 530.26-TG3YI ® SUNLINE 2000 (OPTION / ACCESS.) DCE UNITS ALUMINIZED STEEL THROWAWAY D*CG UNITS (OPTION / ACCESSORY) FEMALE MODEL DCG (Gas Heating) RATINGS CAPACITY RATINGS - Cooling / Electric Heating Model Rating1 Point Total Output, Mbh / kW Total Input, kW COP2 EER3 Sensible Output, Mbh / kW Latent Output, Mbh / kW T1 T2 T3 T1 T2 T3 159 / 46.6 142 / 41.7 152 / 44.6 210 / 61.5 182 / 53.3 196 / 57.5 18.2 20.0 16.4 24.8 27.1 22.2 2.60 2.10 2.75 2.50 2.00 2.60 8.80 7.15 9.40 8.50 6.75 8.80 132 / 38.7 141 / 41.2 119 / 34.9 176 / 51.5 182 / 53.3 152 / 44.6 26.9 / 7.9 1.6 / 0.5 33.2 / 9.7 34.0 / 10.0 0.0 / 0.0 42.6 / 12.5 D3CE180 D3CE240 Electric Heat4 Nominal Capacity, kW 18, 36, 54, 72 18, 36, 54, 72 1 T1 = Moderate Climates, T2 = Hot Climates, T3 = Cool Climates. 2 COP = Coefficient of Performance - total output kW divided by the total input kW. 3 EER = Energy Efficiency Ratio - total output Mbh divided by the total input kW. 4 Heaters available as factory-installed options or field-installed accessories - all with single point power supply. CAPACITY RATINGS - Gas Heating Gas Heat Capacity Model Cooling Capacity, Mbh / kW D3CG180N320 D3CG240N320 180 / 52.7 240 / 70.3 Input (Net) Mbh / kW Output Mbh / kW Gas Rate* cfh / m3/h 291 / 85.2 258 / 75.6 302 / 8.5 Temp. Rise (°F / °C) At Full Input Min. Max. 30 / 17 60 / 33 NOTE: Gas Heaters are shipped available for natural gas, but can be converted to L.P. / propane gas with a field-installed conversion accessory. All gas units are two-stage heating. First stage is 50% of total. *Based on net input and 2nd. -H family, G20 (methane) net fuel value (9.97 kWh/m3). Unitary Products Group 3 530.26-TG3YI COOLING CAPACITIES (m3/s Air Flow) - 180 UNITS Air On Evaporator Coil m3/s WB °C 3.40 2.80 2.10 3.40 2.80 2.10 3.40 2.80 2.10 Total Cap.1 kW 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 66.4 62.3 58.2 56.7 55.2 61.5 57.7 53.9 52.5 51.1 57.1 53.6 50.1 48.7 47.4 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 60.7 57.2 53.7 52.3 51.0 56.3 53.1 49.8 48.6 47.3 51.9 48.9 45.9 44.7 43.6 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 49.6 47.3 45.0 43.6 42.1 49.4 47.2 44.9 43.4 42.0 46.5 44.4 42.3 40.9 39.5 Sensible Capacity1, kW Entering Dry Bulb Temp., °C 32 30 28 26 @27°C Air Temperature on Condenser Coil 14.7 51 44 37 30 14.4 59 52 44 37 14.0 58 58 52 45 14.0 57 57 56 49 13.9 55 55 55 52 14.5 46 40 34 27 14.2 53 46 40 34 13.9 54 53 47 41 13.8 52 52 51 44 13.7 51 51 51 48 14.3 37 32 28 23 14.0 43 38 33 29 13.6 48 44 39 34 13.6 49 47 42 37 13.5 47 47 45 40 @35°C Air Temperature on Condenser Coil 15.9 50 43 36 29 15.5 57 50 43 36 15.2 54 54 51 43 15.1 52 52 52 47 15.0 51 51 51 47 15.9 44 38 32 25 15.6 51 44 38 32 15.2 50 50 45 39 15.1 49 49 48 41 15.0 47 47 47 44 15.6 36 31 27 22 15.3 41 37 32 27 14.9 46 42 38 33 14.8 45 45 40 35 14.7 44 44 43 38 @46°C Air Temperature on Condenser Coil 18.2 46 39 32 25 17.6 47 46 39 32 17.1 45 45 45 39 17.1 44 44 44 40 17.1 42 42 42 39 17.8 41 35 29 23 17.2 47 42 36 29 16.6 45 45 42 36 16.6 43 43 43 37 16.6 42 42 42 39 17.5 33 29 24 19 17.0 39 34 30 25 16.4 42 40 35 31 16.4 41 41 36 32 16.4 40 40 38 33 Power Input2 kW 24 22 23 30 38 41 45 21 28 35 38 42 19 24 30 33 36 23 31 34 37 22 28 32 35 19 25 28 31 22 29 36 40 40 19 26 32 35 38 17 23 28 31 33 22 29 32 33 20 26 29 32 18 24 26 29 18 25 32 33 31 17 23 30 31 33 15 20 26 27 28 18 25 26 24 17 24 25 27 16 21 22 24 1 These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2 These ratings include the condenser fan motors (Total 2.3 kW) and the compressor motors but not the supply air blower motor. 4 Unitary Products Group 530.26-TG3YI COOLING CAPACITIES (CFM Air Flow) - 180 UNITS Air On Evaporator Coil CFM WB °F 7200 5930 4450 7200 5930 4450 7200 5930 4450 Total Cap.1 MBH 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 227 213 199 193 188 210 197 184 179 174 195 183 171 166 162 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 207 195 183 179 174 192 181 170 166 161 177 167 157 153 149 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 169 161 154 149 144 169 161 153 148 143 159 151 144 139 135 Sensible Capacity1, MBH Entering Dry Bulb Temp., °F 90 86 82 79 @80°F Air Temperature on Condenser Coil1 14.7 175 151 126 102 14.4 200 176 152 127 14.0 199 199 177 153 14.0 193 193 190 166 13.9 188 188 188 176 14.5 157 136 115 93 14.2 180 159 138 116 13.9 184 182 160 139 13.8 179 179 172 151 13.7 174 174 174 163 14.3 127 111 95 79 14.0 146 130 114 98 13.6 165 149 133 117 13.6 166 159 143 127 13.5 162 162 153 137 @95°F Air Temperature on Condenser Coil 15.9 170 146 122 98 15.5 195 171 147 123 15.2 183 183 172 148 15.1 179 179 179 159 15.0 174 174 174 162 15.9 150 129 108 87 15.6 172 151 130 109 15.2 170 170 153 132 15.1 166 166 162 141 15.0 161 161 161 151 15.6 123 107 91 75 15.3 142 126 110 94 14.9 157 145 129 113 14.8 153 153 137 121 14.7 149 149 145 129 @115°F Air Temperature on Condenser Coil 18.2 157 133 109 85 17.6 161 158 134 110 17.1 154 154 154 135 17.1 149 149 149 137 17.1 144 144 144 132 17.8 141 120 99 78 17.2 161 142 121 100 16.6 153 153 144 123 16.6 148 148 148 128 16.6 143 143 143 133 17.5 114 98 82 66 17.0 133 117 101 85 16.4 144 136 120 104 16.4 139 139 124 108 16.4 135 135 128 112 Power Input2 kW 75 72 78 103 128 142 152 72 95 118 130 142 63 82 101 111 121 79 104 117 128 74 97 109 121 66 86 96 105 74 99 124 135 138 66 88 110 120 130 59 78 97 105 113 75 100 111 113 67 89 99 109 62 81 89 97 61 85 110 112 107 57 79 102 107 112 50 69 88 92 96 61 86 88 83 58 81 86 90 53 72 76 80 1 These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2 These ratings include the condenser fan motors (Total 2.3 kW) and the compressor motors but not the supply air blower motor. Unitary Products Group 5 530.26-TG3YI COOLING CAPACITIES (m3/s Air Flow) - 240 UNITS Air On Evaporator Coil m3/s WB °C 4.40 3.80 2.80 4.40 3.80 2.80 4.40 3.80 2.80 Total Cap.1 kW 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 80.4 77.6 74.8 72.4 70.0 76.9 74.3 71.6 69.3 67.0 71.2 68.7 66.3 64.1 62.0 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 74.9 72.3 69.8 67.4 65.0 71.3 68.9 66.4 64.2 61.9 65.4 63.1 60.9 58.8 56.7 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 66.4 63.3 60.2 59.0 57.8 63.8 60.8 57.8 56.7 55.5 59.4 56.6 53.8 52.8 51.7 Sensible Capacity1, kW Entering Dry Bulb Temp., °C 32 30 28 26 @27°C Air Temperature on Condenser Coil 19.0 74 65 55 46 18.8 78 70 61 52 18.6 75 75 67 57 18.4 72 72 71 62 18.1 70 70 70 65 18.8 68 60 52 44 18.6 73 65 57 49 18.4 72 70 62 54 18.2 69 69 67 59 17.9 67 67 67 63 18.5 56 50 44 37 18.3 60 54 48 42 18.1 65 59 52 46 17.9 64 62 56 50 17.6 62 62 60 54 @35°C Air Temperature on Condenser Coil 21.0 71 61 52 43 20.7 72 68 58 49 20.4 70 70 65 55 20.1 67 67 67 58 19.9 65 65 65 60 20.7 65 57 49 41 20.5 69 62 54 46 20.2 66 66 60 52 19.9 64 64 63 55 19.7 62 62 62 58 20.4 52 46 40 34 20.1 57 51 45 39 19.8 61 56 50 44 19.6 59 58 52 46 19.3 57 57 54 48 @46°C Air Temperature on Condenser Coil 23.4 65 56 47 38 22.9 63 62 53 44 22.3 60 60 60 51 22.3 59 59 59 53 22.2 58 58 58 53 23.3 60 52 44 36 22.7 61 58 50 42 22.2 58 58 56 48 22.1 57 57 57 50 22.1 56 56 56 52 23.1 49 42 36 30 22.5 54 47 41 35 22.0 54 53 46 40 21.9 53 53 48 42 21.9 52 52 49 43 Power Input2 kW 24 22 37 43 48 53 56 36 41 46 51 55 31 36 40 44 47 33 39 44 47 33 38 43 47 30 34 38 41 34 40 46 49 51 33 38 44 47 50 28 33 38 40 42 31 37 40 42 30 36 39 42 27 31 34 36 29 35 41 43 44 28 34 40 42 44 24 29 34 36 37 26 32 34 35 26 32 34 35 23 28 30 31 1 These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2 These ratings include the condenser fan motors (Total 2.3 kW) and the compressor motors but not the supply air blower motor. 6 Unitary Products Group 530.26-TG3YI COOLING CAPACITIES (CFM Air Flow) - 240 UNITS Air On Evaporator Coil CFM WB °F 9320 8050 5930 9320 8050 5930 9320 8050 5930 Total Cap.1 MBH 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 274 265 255 247 239 263 253 244 236 229 243 234 226 219 212 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 256 247 238 230 222 243 235 227 219 211 223 215 208 201 193 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 226 216 205 201 197 218 207 197 193 189 203 193 184 180 176 Sensible Capacity1, MBH Entering Dry Bulb Temp., °F 90 86 82 79 @80°F Air Temperature on Condenser Coil 19.0 252 221 189 158 18.8 265 240 208 177 18.6 255 255 227 196 18.4 247 247 243 211 18.1 239 239 239 223 18.8 232 205 177 150 18.6 250 222 195 168 18.4 244 240 213 186 18.2 236 236 228 200 17.9 229 229 229 215 18.5 191 170 149 128 18.3 206 185 164 143 18.1 221 200 179 158 17.9 219 212 191 170 17.6 212 212 204 183 @95°F Air Temperature on Condenser Coil 21.0 241 209 178 147 20.7 247 230 199 168 20.4 238 238 220 189 20.1 230 230 230 199 19.9 222 222 222 206 20.7 221 193 166 139 20.5 235 213 186 158 20.2 227 227 206 178 19.9 219 219 215 188 19.7 211 211 211 197 20.4 179 158 137 116 20.1 195 174 153 133 19.8 208 191 170 149 19.6 201 199 178 157 19.3 193 193 186 165 @115°F Air Temperature on Condenser Coil 23.4 223 191 160 129 22.9 216 213 182 151 22.3 205 205 204 172 22.3 201 201 201 179 22.2 197 197 197 182 23.3 204 177 149 122 22.7 207 197 170 142 22.2 197 197 190 163 22.1 193 193 193 169 22.1 189 189 189 176 23.1 166 145 124 103 22.5 183 162 141 120 22.0 184 179 158 137 21.9 180 180 164 143 21.9 176 176 169 148 Power Input2 kW 75 72 127 146 164 180 192 123 141 158 173 188 107 122 137 149 162 114 133 149 161 113 131 146 160 101 116 128 141 115 136 157 168 175 111 131 151 161 170 95 112 128 136 144 105 126 136 143 104 124 133 143 91 107 115 123 97 119 141 148 150 95 115 136 142 148 82 99 116 122 127 88 110 117 119 88 108 115 121 78 95 101 106 1 These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2 These ratings include the condenser fan motors (Total 2.3 kW) and the compressor motors but not the supply air blower motor. Unitary Products Group 7 530.26-TG3YI BLOWER PERFORMANCE (D*CE180 UNIT SUPPLY AIR) w/DOWNFLOW DUCT APPLICATIONS STANDARD DRIVE (m3 /s) BLOWER SPEED, RPM 845 885 925 960 1000 1040 MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 ESP (Pa) 173 208 245 281 323 369 2.10 m3/s Output Input (kW) (kW) 1.8 2.2 1.9 2.3 2.0 2.4 2.1 2.6 2.3 2.7 2.4 2.9 ESP (Pa) 138 172 208 242 283 327 2.45 m3/s Output (kW) 2.2 2.3 2.4 2.6 2.7 2.9 ESP (Pa) 316 362 416 468 529 587 2.45 m3/s Output Input (kW) (kW) 2.8 3.4 3.0 3.6 3.2 3.8 3.4 4.0 3.6 4.3 3.8 4.5 Input (kW) 2.6 2.8 2.9 3.1 3.2 3.4 AIRFLOW 2.80 m3/s ESP Output Input (Pa) (kW) (kW) 83 2.6 3.1 115 2.7 3.3 149 2.9 3.4 182 3.0 3.6 222 3.2 3.8 264 3.3 4.0 ESP (Pa) 18 49 82 114 152 193 3.10 m3/s Output Input (kW) (kW) 3.0 3.5 3.1 3.7 3.3 3.9 3.4 4.1 3.6 4.3 3.8 4.5 ESP (Pa) 30 67 107 3.40 m3/s Output Input (kW) (kW) 3.8 4.6 4.0 4.8 4.2 5.1 HIGH SPEED DRIVE (m3 /s) BLOWER SPEED, RPM 1030 1070 1115 1155 1200 1240 MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 ESP (Pa) 357 405 461 514 577 636 2.10 m3/s Output (kW) 2.4 2.5 2.7 2.9 3.1 3.3 Input (kW) 2.8 3.0 3.2 3.4 3.7 3.9 AIRFLOW 2.80 m3/s ESP Output Input (Pa) (kW) (kW) 253 3.3 3.9 298 3.5 4.2 351 3.7 4.4 401 3.9 4.7 461 4.1 5.0 - ESP (Pa) 183 226 278 - 3.10 m3/s Output Input (kW) (kW) 3.7 4.5 3.9 4.7 4.2 5.0 - 3.40 m3/s ESP Output Input (Pa) (kW) (kW) 97 4.2 5.0 - STANDARD DRIVE (CFM) MOTOR BLOWER PULLEY SPEED, (TURNS RPM OPEN)* 845 885 925 960 1000 1040 6.0 5.0 4.0 3.0 2.0 1.0 4450 CFM ESP Output Input (iwg) (bhp) (kW) 0.7 2.4 2.2 0.8 2.6 2.3 1.0 2.7 2.4 1.1 2.9 2.6 1.3 3.0 2.7 1.5 3.2 2.9 5190 CFM ESP Output Input (iwg) (bhp) (kW) 0.6 2.9 2.6 0.7 3.1 2.8 0.8 3.3 2.9 1.0 3.4 3.1 1.1 3.6 3.2 1.3 3.8 3.4 AIRFLOW 5930 CFM ESP Output Input (iwg) (bhp) (kW) 0.3 3.5 3.1 0.5 3.7 3.3 0.6 3.8 3.4 0.7 4.0 3.6 0.9 4.2 3.8 1.1 4.5 4.0 6565 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 4.0 3.5 0.2 4.2 3.7 0.3 4.4 3.9 0.5 4.6 4.1 0.6 4.8 4.3 0.8 5.1 4.5 7200 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 5.2 4.6 0.3 5.4 4.8 0.4 5.7 5.1 HIGH SPEED DRIVE (CFM) BLOWER SPEED, RPM MOTOR PULLEY (TURNS OPEN)* 1030 1070 1115 1155 1200 1240 6.0 5.0 4.0 3.0 2.0 1.0 NOTES: 8 4450 CFM ESP Output Input (iwg) (bhp) (kW) 1.4 3.2 2.8 1.6 3.4 3.0 1.9 3.6 3.2 2.1 3.9 3.4 2.3 4.1 3.7 2.6 4.4 3.9 5190 CFM ESP Output Input (iwg) (bhp) (kW) 1.3 3.8 3.4 1.5 4..0 3.6 1.7 4.3 3.8 1.9 4.5 4.0 2.1 4.8 4.3 2.4 5.1 4.5 AIRFLOW 5930 CFM ESP Output Input (iwg) (bhp) (kW) 1.0 4.4 3.9 1.2 4.7 4.2 1.4 5.0 4.4 1.6 5.2 4.7 1.8 5.5 5.0 - 6565 CFM ESP Output Input (iwg) (bhp) (kW) 0.7 5.0 4.5 0.9 5.3 4.7 1.1 5.6 5.0 - 7200 CFM ESP Output Input (iwg) (bhp) (kW) 0.4 5.6 5.0 - 1. Blower performance values include fixed outdoor air, a dry indoor coil, the standard unit filters and no electric heat. 2. Refer to Page 12 for the resistance values for all other unit options or applications. ESP = External Static Pressure available for the supply and return air duct system. All internal unit resistances have been deducted from the total static pressure of the blower. *Do NOT close pulley below minimum turns open. Unitary Products Group 530.26-TG3YI BLOWER PERFORMANCE (D*CE240 UNIT SUPPLY AIR) w/DOWNFLOW DUCT APPLICATIONS STANDARD DRIVE (m3 /s) BLOWER SPEED, RPM MOTOR PULLEY (TURNS OPEN)* 765 795 820 850 875 905 6.0 5.0 4.0 3.0 2.0 1.0 ESP (Pa) 137 176 209 250 284 327 2.80 m3/s Output (kW) 2.9 3.0 3.1 3.3 3.4 3.6 Input (kW) 3.3 3.4 3.6 3.8 3.9 4.1 ESP (Pa) 93 132 165 206 240 283 3.30 m3/s Output Input (kW) (kW) 2.9 3.3 3.1 3.5 3.2 3.7 3.4 3.9 3.6 4.1 3.8 4.3 AIRFLOW 3.80 m3/s ESP Output Input (Pa) (kW) (kW) 23 3.2 3.7 62 3.4 3.9 95 3.6 4.1 136 3.8 4.4 170 4.0 4.6 212 4.3 4.9 ESP (Pa) 40 81 115 157 ESP (Pa) 268 318 377 429 491 546 3.30 m3/s Output Input (kW) (kW) 3.7 4.3 4.0 4.5 4.2 4.9 4.5 5.1 4.8 5.5 5.0 5.8 AIRFLOW 3.80 m3/s ESP Output Input (Pa) (kW) (kW) 198 4.2 4.8 248 4.5 5.1 306 4.8 5.5 359 5.1 5.8 420 5.4 6.2 475 5.7 6.5 4.10 m3/s ESP Output Input (Pa) (kW) (kW) 143 4.6 5.2 193 4.9 5.6 252 5.2 6.0 304 5.6 6.4 365 5.9 6.8 420 6.2 7.1 6990 CFM ESP Output Input (iwg) (bhp) (kW) 0.4 3.9 3.3 0.5 4.1 3.5 0.7 4.4 3.7 0.8 4.6 3.9 1.0 4.8 4.1 1.1 5.1 4.3 AIRFLOW 8050 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 4.3 3.7 0.2 4.6 3.9 0.4 4.8 4.1 0.5 5.1 4.4 0.7 5.4 4.6 0.9 5.7 4.9 8685 CFM ESP Output Input (iwg) (bhp) (kW) 0.2 5.3 4.5 0.3 5.6 4.8 0.5 5.9 5.0 0.6 6.3 5.3 6990 CFM ESP Output Input (iwg) (bhp) (kW) 1.1 5.0 4.3 1.3 5.3 4.5 1.5 5.7 4.9 1.7 6.0 5.1 2.0 6.4 5.5 2.2 6.8 5.8 AIRFLOW 8050 CFM ESP Output Input (iwg) (bhp) (kW) 0.8 5.6 4.8 1.0 6.0 5.1 1.2 6.4 5.5 1.4 6.8 5.8 1.7 7.3 6.2 1.9 7.7 6.5 8685 CFM ESP Output Input (iwg) (bhp) (kW) 0.6 6.1 5.2 0.8 6.6 5.6 1.0 7.0 6.0 1.2 7.4 6.4 1.5 7.9 6.8 1.7 8.4 7.1 4.10 m3/s Output Input (kW) (kW) 4.0 4.5 4.2 4.8 4.4 5.0 4.7 5.3 ESP (Pa) 16 51 93 4.40 m3/s Output Input (kW) (kW) 4.7 5.3 4.9 5.6 5.2 5.9 HIGH SPEED DRIVE (m3 /s) BLOWER SPEED, RPM MOTOR PULLEY (TURNS OPEN)* 895 930 970 1005 1045 1080 6.0 5.0 4.0 3.0 2.0 1.0 ESP (Pa) 312 362 421 473 535 590 2.80 m3/s Output (kW) 3.5 3.7 4.0 4.2 4.4 4.6 Input (kW) 4.0 4.3 4.5 4.8 5.0 5.3 4.40 m3/s ESP Output Input (Pa) (kW) (kW) 79 5.1 5.8 129 5.4 6.2 187 5.8 6.6 240 6.1 7.0 - STANDARD DRIVE (CFM) BLOWER SPEED, RPM MOTOR PULLEY (TURNS OPEN)* 765 795 820 850 875 905 6.0 5.0 4.0 3.0 2.0 1.0 5930 CFM ESP Output Input (iwg) (bhp) (kW) 0.6 3.8 3.3 0.7 4.0 3.4 0.8 4.2 3.6 1.0 4.4 3.8 1.1 4.6 3.9 1.3 4.8 4.1 9320 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 6.2 5.3 0.2 6.6 5.6 0.4 6.9 5.9 HIGH SPEED DRIVE (CFM) BLOWER SPEED, RPM MOTOR PULLEY (TURNS OPEN)* 895 930 970 1005 1045 1080 6.0 5.0 4.0 3.0 2.0 1.0 NOTES: 5930 CFM ESP Output Input (iwg) (bhp) (kW) 1.3 4.7 4.0 1.5 5.0 4.3 1.7 5.3 4.5 1.9 5.6 4.8 2.1 5.9 5.0 2.4 6.2 5.3 9320 CFM ESP Output Input (iwg) (bhp) (kW) 0.3 6.8 5.8 0.5 7.2 6.2 0.8 7.8 6.6 1.0 8.2 7.0 - 1. Blower performance values include fixed outdoor air, a dry indoor coil, the standard unit filters and no electric heat. 2. Refer to Page 12 for the resistance values for all other unit options or applications. ESP = External Static Pressure available for the supply and return air duct system. All internal unit resistances have been deducted from the total static pressure of the blower. *Do NOT close pulley below minimum turns open. Unitary Products Group 9 530.26-TG3YI BLOWER PERFORMANCE (D*CG180 UNIT SUPPLY AIR) w/DOWNFLOW DUCT APPLICATIONS 3 STANDARD DRIVE (m /s) BLOWER SPEED, RPM MOTOR PULLEY (TURNS OPEN)* 845 885 925 960 1000 1040 6.0 5.0 4.0 3.0 2.0 1.0 ESP (Pa) 206 242 278 311 349 387 2.10 m3/s Output (kW) 1.8 1.9 2.0 2.1 2.2 2.3 Input (kW) 2.2 2.3 2.4 2.5 2.6 2.8 ESP (Pa) 146 183 220 253 292 331 2.45 m3/s Output Input (kW) (kW) 2.0 2.5 2.2 2.6 2.3 2.7 2.4 2.9 2.6 3.1 2.7 3.3 AIRFLOW 2.80 m3/s ESP Output Input (Pa) (kW) (kW) 80 2.4 2.8 117 2.5 3.0 155 2.7 3.2 189 2.8 3.4 228 3.0 3.6 268 3.2 3.9 ESP (Pa) 321 361 407 448 495 538 2.45 m3/s Output Input (kW) (kW) 2.7 3.2 2.9 3.4 3.1 3.7 3.3 4.0 3.6 4.3 3.8 4.6 AIRFLOW 2.80 m3/s ESP Output Input (Pa) (kW) (kW) 258 3.2 3.8 299 3.4 4.1 345 3.7 4.4 387 3.9 4.7 435 4.2 5.0 - ESP (Pa) 18 56 94 128 168 209 3.10 m3/s Output Input (kW) (kW) 2.7 3.2 2.9 3.4 3.1 3.7 3.2 3.9 3.5 4.2 3.7 4.4 3.40 m3/s Output Input (kW) (kW) 3.5 4.2 3.7 4.5 4.0 4.8 4.3 5.1 ESP (Pa) 28 63 103 144 ESP (Pa) 199 240 286 - 3.10 m3/s Output Input (kW) (kW) 3.6 4.4 3.9 4.7 4.2 5.0 - 3.40 m3/s ESP Output Input (Pa) (kW) (kW) 134 4.2 5.0 - 6565 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 3.6 3.2 0.2 3.8 3.4 0.4 4.1 3.7 0.5 4.3 3.9 0.7 4.7 4.2 0.8 5.0 4.4 7200 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 4.7 4.2 0.3 5.0 4.5 0.4 5.3 4.8 0.6 5.7 5.1 6565 CFM ESP Output Input (iwg) (bhp) (kW) 0.8 4.9 4.4 1.0 5.2 4.7 1.2 5.6 5.0 - 7200 CFM ESP Output Input (iwg) (bhp) (kW) 0.5 5.6 5.0 - HIGH SPEED DRIVE (m3 /s) BLOWER SPEED, RPM 1030 1070 1115 1155 1200 1240 MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 ESP (Pa) 378 417 461 502 548 590 2.10 m3/s Output (kW) 2.3 2.4 2.6 2.8 3.0 3.2 Input (kW) 2.7 2.9 3.1 3.3 3.6 3.8 STANDARD DRIVE (CFM) MOTOR BLOWER PULLEY SPEED, (TURNS RPM OPEN)* 845 6.0 885 5.0 925 4.0 960 3.0 1000 2.0 1040 1.0 4450 CFM ESP Output Input (iwg) (bhp) (kW) 0.8 2.5 2.2 1.0 2.6 2.3 1.1 2.7 2.4 1.2 2.8 2.5 1.4 2.9 2.6 1.6 3.1 2.8 5190 CFM ESP Output Input (iwg) (bhp) (kW) 0.6 2.7 2.5 0.7 2.9 2.6 0.9 3.1 2.7 1.0 3.2 2.9 1.2 3.4 3.1 1.3 3.7 3.3 AIRFLOW 5930 CFM ESP Output Input (iwg) (bhp) (kW) 0.3 3.2 2.8 0.5 3.4 3.0 0.6 3.6 3.2 0.8 3.8 3.4 0.9 4.0 3.6 1.1 4.3 3.9 HIGH SPEED DRIVE (CFM) BLOWER SPEED, RPM MOTOR PULLEY (TURNS OPEN)* 1030 1070 1115 1155 1200 1240 6.0 5.0 4.0 3.0 2.0 1.0 NOTES: 10 4450 CFM ESP Output Input (iwg) (bhp) (kW) 1.5 3.1 2.7 1.7 3.3 2.9 1.9 3.5 3.1 2.0 3.7 3.3 2.2 4.0 3.6 2.4 4.3 3.8 5190 CFM ESP Output Input (iwg) (bhp) (kW) 1.3 3.6 3.2 1.4 3.8 3.4 1.6 4.1 3.7 1.8 4.4 4.0 2.0 4.8 4.3 2.2 5.1 4.6 AIRFLOW 5930 CFM ESP Output Input (iwg) (bhp) (kW) 1.0 4.3 3.8 1.2 4.5 4.1 1.4 4.9 4.4 1.6 5.2 4.7 1.7 5.6 5.0 - 1. Blower performance values include fixed outdoor air, a dry indoor coil, the standard unit filters and no electric heat. 2. Refer to Page 12 for the resistance values for all other unit options or applications. ESP = External Static Pressure available for the supply and return air duct system. All internal unit resistances have been deducted from the total static pressure of the blower. *Do NOT close pulley below minimum turns open. Unitary Products Group 530.26-TG3YI BLOWER PERFORMANCE (D*CG240 UNIT SUPPLY AIR) w/DOWNFLOW DUCT APPLICATIONS STANDARD DRIVE (m3 /s) BLOWER SPEED, RPM MOTOR PULLEY (TURNS OPEN)* 765 795 820 850 875 905 6.0 5.0 4.0 3.0 2.0 1.0 ESP (Pa) 202 238 268 305 336 347 2.80 m3/s Output (kW) 2.1 2.3 2.4 2.5 2.7 2.8 Input (kW) 2.4 2.6 2.7 2.9 3.0 3.2 ESP (Pa) 80 117 150 189 222 262 3.30 m3/s Output Input (kW) (kW) 2.7 3.1 2.9 3.3 3.0 3.4 3.2 3.7 3.4 3.8 3.6 4.1 AIRFLOW 3.80 m3/s ESP Output Input (Pa) (kW) (kW) 50 3.9 4.5 85 4.1 4.7 128 4.3 5.0 4.10 m3/s ESP Output Input (Pa) (kW) (kW) 37 4.8 5.5 4.40 m3/s ESP Output Input (Pa) (kW) (kW) - ESP (Pa) 249 290 332 381 425 469 514 3.30 m3/s Output Input (kW) (kW) 3.5 4.0 3.7 4.2 3.9 4.4 4.1 4.7 4.3 5.0 4.6 5.2 4.8 5.5 AIRFLOW 3.80 m3/s ESP Output Input (Pa) (kW) (kW) 114 4.3 4.9 157 4.5 5.1 201 4.7 5.4 254 5.0 5.7 299 5.2 6.0 346 5.5 6.3 393 5.8 6.6 ESP (Pa) 22 66 112 166 213 261 310 4.10 m3/s Output Input (kW) (kW) 4.7 5.4 5.0 5.7 5.2 6.0 5.5 6.3 5.8 6.7 6.1 7.0 6.4 7.3 4.40 m3/s Output Input (kW) (kW) 5.8 6.6 6.1 7.0 6.4 7.3 - 6990 CFM ESP Output Input (iwg) (bhp) (kW) 0.3 3.6 3.1 0.5 3.8 3.3 0.6 4.0 3.4 0.8 4.3 3.7 0.9 4.5 3.8 1.1 4.8 4.1 AIRFLOW 8050 CFM ESP Output Input (iwg) (bhp) (kW) 0.2 5.3 4.5 0.3 5.5 4.7 0.5 5.8 5.0 8685 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 6.5 5.5 9320 CFM ESP Output Input (iwg) (bhp) (kW) - 6990 CFM ESP Output Input (iwg) (bhp) (kW) 1.0 4.7 4.0 1.2 4.9 4.2 1.3 5.2 4.4 1.5 5.5 4.7 1.7 5.8 5.0 1.9 6.1 5.2 2.1 6.4 5.5 AIRFLOW 8050 CFM ESP Output Input (iwg) (bhp) (kW) 0.5 5.7 4.9 0.6 6.0 5.1 0.8 6.3 5.4 1.0 6.7 5.7 1.2 7.0 6.0 1.4 7.4 6.3 1.6 7.7 6.6 8685 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 6.3 5.4 0.3 6.7 5.7 0.4 7.0 6.0 0.7 7.4 6.3 0.9 7.8 6.7 1.0 8.2 7.0 1.2 8.5 7.3 9320 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 7.8 6.6 0.3 8.2 7.0 0.5 8.6 7.3 - HIGH SPEED DRIVE (m3 /s) BLOWER SPEED, RPM MOTOR PULLEY (TURNS OPEN)* 895 925 955 990 1020 1050 1080 6.0 5.0 4.0 3.0 2.0 1.0 0.0 ESP (Pa) 361 400 439 486 527 569 612 2.80 m3/s Output (kW) 2.8 2.9 3.1 3.3 3.5 3.7 3.9 Input (kW) 3.2 3.4 3.6 3.8 4.0 4.2 4.4 ESP (Pa) 15 70 119 - STANDARD DRIVE (CFM) BLOWER SPEED, RPM 765 795 820 850 875 905 MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 5930 CFM ESP Output Input (iwg) (bhp) (kW) 0.8 2.8 2.4 1.0 3.0 2.6 1.1 3.2 2.7 1.2 3.4 2.9 1.3 3.6 3.0 1.5 3.8 3.2 HIGH SPEED DRIVE (CFM) BLOWER SPEED, RPM MOTOR PULLEY (TURNS OPEN)* 895 925 955 990 1020 1050 1080 6.0 5.0 4.0 3.0 2.0 1.0 0.0 NOTES: 5930 CFM ESP Output Input (iwg) (bhp) (kW) 1.5 3.7 3.2 1.6 3.9 3.4 1.8 4.2 3.6 2.0 4.4 3.8 2.1 4.7 4.0 2.3 4.9 4.2 2.5 5.2 4.4 1. Blower performance values include fixed outdoor air, a dry indoor coil, the standard unit filters and no electric heat. 2. Refer to Page 12 for the resistance values for all other unit options or applications. ESP = External Static Pressure available for the supply and return air duct system. All internal unit resistances have been deducted from the total static pressure of the blower. *Do NOT close pulley below minimum turns open. Unitary Products Group 11 530.26-TG3YI BLOWER MOTOR AND DRIVE DATA MOTOR1 BLOWER RANGE (RPM) kW/HP FRAME EFF. SIZE (%) UNIT SIZE STD. DRIVE HIGH SPEED DRIVE 180 845-1040 3.0 / 4.0 184T 84 240 765-905 5.6 / 7.5 213T 87 180 1030-1240 3.0 / 4.0 184T 84 240 213T 87 895-1080 5.6 / 7.5 ADJUSTABLE MOTOR PULLEY2 PITCH BORE DESIGDIA. (mm/in.) NATION (mm/in.) 109-135 29 / 11⁄8 1VP56 4.3-5.3 140-165 35 / 13⁄8 1VP68 5.5-6.5 124-150 29 / 11⁄8 1VP62 4.9-5.9 147-178 35 / 13⁄8 1VP75 5.8-7.0 FIXED BLOWER PULLEY PITCH BORE DESIGDIA. (mm/in.) NATION (mm / in.) 188 / 7.4 25 / 1 BK80 BELT (NOTCHED) PITCH LENGTH (mm/in.) DESIGQTY NATION 1773 / 69.8 BX68 1 264 / 10.4 30 / 13⁄16 BK110 2103 / 82.8 BX81 1 175 / 6.9 25 / 1 BK75 1773 / 69.8 BX68 1 239 / 9.4 30 / 13⁄16 BK100 2103 / 82.8 BX81 1 1 All motors are totally enclosed, fan cooled (TEFC), 1450 RPM with solid bases and a 1.15 service factor. 2 Do NOT close this pulley below the minimum number of turns open. STATIC RESISTANCES* EXTERNAL STATIC [RESSURE DRP RESISTANCE, Pa/IWG M3/S / CFM DESCRIPTION MODEL 180 MODEL 240 2.1 / 4500 2.8 / 6000 3.4 / 7200 2.8 / 6000 3.8 / 8000 4.4 / 9400 24.8 / 0.1 24.8 / 0.1 24.8 / 0.1 24.8 / 0.1 24.8 / 0.1 24.8 / 0.1 18 kW 24.8 / 0.1 24.8 / 0.1 24.8 / 0.1 24.8 / 0.1 24.8 / 0.1 24.8 / 0.1 36 kW 24.8 / 0.1 50.0 / 0.2 74.4 / 0.3 24.8 / 0.1 50.0 / 0.2 74.4 / 0.3 54 kW 50.0 / 0.2 74.4 / 0.3 99.2 / 0.4 50.0 / 0.2 74.4 / 0.3 99.2 / 0.4 72 kW 50.0 / 0.2 99.2 / 0.4 149.0 / 0.6 50.0 / 0.2 99.2 / 0.4 149.0 / 0.6 ECONOMIZER OPTION 24.8 / 0.1 24.8 / 0.1 24.8 / 0.1 24.8 / 0.1 24.8 / 0.1 24.8 / 0.1 HORIZONTAL DUCT CONNECTIONS 50.0 / 0.2 74.4 / 0.3 124.0 / 0.5 50.0 / 0.2 74.4 / 0.3 124.0 / 0.5 WET COIL ELECTRIC HEAT OPTIONS * Deduct these resistance values from the available unit ESP values listed in the respective blower performance table except for Horizontal Duct Connections. Add the Horizontal Duct Connection values due to less airflow resistance. 12 Unitary Products Group 530.26-TG3YI FIELD WIRING - Electric/Electric and Gas/Electric Units 24 VOLT TRANSFORMER LINE VOLTAGE TERMINAL BLOCK 2TB IN UNIT CONTROL BOX L1 NEUTRAL TERMINAL N Refer to the ELECTRICAL DATA tables to size the power wiring, the fuses and the disconnect switch. L2 L3 GRD. LUG ELECTRICAL DATA - Cooling Only Units and Units With Gas Heat UNIT SIZE POWER SUPPLY 180 240 380/400/415-3+N-50 380/400/415-3+N-50 NOTES: COMPRESSOR RLA #1 #2 19.2 9.6 19.2 19.2 LRA #1 #2 146 73 146 146 OUTDOOR FAN MOTOR, (#1 & #2) FLA, EACH 2.4 2.4 SUPPLY AIR BLOWER MOTOR, (FLA) 3 kW 5.6 kW 4 HP 7.5 HP 8.6 11.7 TOTAL UNIT AMPACITY, (AMPS) 3 kW 5.6 kW 4 HP 7.5 HP 47.0 59.7 MAX. FUSE SIZE1 MIN. WIRE SIZE2, (mm2/AWG) 60 70 10 / 8 16 / 6 1. Slow blow type fuse. 2. Based on 105°C insulated copper conductors in conduit. Unitary Products Group 13 530.26-TG3YI ELECTRICAL DATA - Units With Supplemental Electric Heating UNIT SIZE POWER SUPPLY (VOLTS) HEATER OPTION MODEL OUTPUT kW STAGES AMPS E018 E036 E054 E072 E018 E036 E054 E072 E018 E036 E054 E072 E018 E036 E054 E072 11.3 22.6 33.8 45.1 13.5 26.9 40.4 53.8 11.3 22.6 33.8 45.1 13.5 26.9 40.4 53.8 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 17.1 34.3 51.4 68.6 18.7 37.4 56.2 74.9 17.1 34.3 51.4 68.6 18.7 37.4 56.2 74.9 380-3+N-50 180 415-3+N-50 380-3+N-50 240 415-3+N-50 NOTES: MINIMUM CIRCUIT AMPACITY (AMPS) 47.0 53.6 75.0 96.5 47.0 57.5 80.9 104.0 59.7 59.7 78.9 100.0 59.7 61.4 84.8 108.0 MAXIMUM FUSE SIZE1 MINIMUM WIRE SIZE2 (mm2/AWG) 60 60 80 100 60 60 90 110 70 70 80 110 70 70 90 110 10 / 8 16 / 6 25 / 4 35 / 2 10 / 8 16 / 6 25 / 4 35 / 2 16 / 6 16 / 6 25 / 4 35 / 2 16 / 6 16 / 6 25 / 4 50 / 2 1. Slow blow type fuse. 2. Based on 105°C copper conductors. PHYSICAL DATA COMPONENT DESCRIPTION SUPPLY AIR BLOWER INDOOR COIL OUTDOOR FANS (Two Per Unit) OUTDOOR COIL COMPRESSOR (Qty. Per Unit) AIR FILTERS CHARGE CENTRIFUGAL BLOWER FAN MOTOR ROWS DEEP FINS PER 25mm (1 in.) FACE AREA PROPELLER DIA. FAN MOTOR NOMINAL AIRFLOW DIA. x WD. (mm) DIA. x WD. (in.) kW / HP m2 / Ft.2 mm / in. kW / HP m3 / s CFM ROWS DEEP FINS PER 25mm (1 in.) FACE AREA m2 / Ft.2 TANDEM (10 TON NOMINAL CAPACITY) HERMETIC (5 TON NOMINAL CAPACITY) 406 x 508 x 51 (mm) QUANTITY PER UNIT 16 x 20 x 2 (in.) 406 x 635 x 51 (mm) QUANTITY PER UNIT 16 x 25 x 2 (in.) 457 x 610 x 51 (mm) QUANTITY PER UNIT 18 x 24 x 2 (in.) TOTAL FACE AREA m2 / Ft.2 SYS. #1 ( kg. / lbs.) REFRIGERANT 22 SYS. #2 (kg. / lbs.) UNIT SIZE (MBH) 180 240 381 x 381 457 x 381 15 x 15 18 x 15 3.7 / 5 5.6 / 7.5 3 3 13.5 13.5 1.45 / 15.5 1.92 / 20.5 762 / 30 (ea.) 762 / 30 (ea.) 0.7 / 1 (ea.) 0.7 / 1 (ea.) 2.83 (ea.) 3.78 (ea.) 6000 (ea.) 8000 (ea.) 2 2 13 20 3.35 / 36.0 4.02 / 43.3 1* 2 1 - 4 - 4 5 - 1.40 / 15.0 7.94 / 17.5 3.86 / 8.5 1.87 / 20.0 8.16 / 18.0 8.16 / 18.0 WEIGHTS (kg. / lbs.) D*CE UNITS 180 866 / 1910 240 957 / 2110 BASIC UNIT D*CG UNITS 180 975 / 2150 240 1066 / 2350 OPTIONS / ACCESSORIES Economizer 73 / 160 Motorized Damper 68 / 150 18 kW 11 / 25 36 kW 14 / 30 Electric Heaters 54 kW 16 / 35 72 kW 18 / 40 180 79 / 175 Roof Curb 240 84 / 185 Barometric Damper 20 / 45 180 91 / 200 Wood Skid* 240 100 / 220 *Allows handling of unit using 2300mm (90") long forks. *This compressor will be energized first. 14 Unitary Products Group 530.26-TG3YI UNIT DIMENSIONS - D*CE180 & 240 UNITS 1235 (48-5/8") (180) 1337 (52-5/8") (240) 3181 (125-1/4") (180) 3461 (136-1/4") (240) 616 (24-1/4") (180) 895 (35-1/4") (240) RETURN AIR All dimensions are in millimeters and inches, unless otherwise specified. They are subject t o chang e wi thout no tice. Cert ifi ed dimensions will be provided upon request. SUPPLY AIR OUTDOOR AIR (Discharge) CLEARANCES (mm / in.) Front Back Left Side (Filter Access) Right Side (Outdoor Coil) Below Unit Above Unit* 914 / 36 610 / 24 (Less Economizer) 1245 / 49 (With Economizer) 610 / 24 (Less Economizer) 1372 / 54 (With Economizer) 914 / 36 20 / 0 1829 / 72 With 914 / 36 Maximum Horizontal Overhang (For Outdoor Air Discharge) NOTE: Unit and ductwork are approved for zero clearance to combustible materials when equipped with electric heat. *Units must be installed oudoors. Overhanging structures or shrubs should not obstruct outdoor air discharge outlet. Unitary Products Group OUTDOOR AIR (Economizer) UTILITIES ENTRY DATA HOLE A B OPENING DIAMETER* (mm / in.) 28.6 / 11⁄8 KO 19.1 / 3⁄4 NPS (Fem.) 92.1 / 35⁄8 KO 76.2 / 3 NPS (Fem.) USED FOR Control Wiring Power Wiring Front Bottom Front Bottom *KO denotes Knockout facility. 15 530.26-TG3YI UNIT DIMENSIONS - D*CG180 & 240 UNITS 1235 (48-5/8") (180) 1337 (52-5/8") (240) 3181 (125-1/4") (180) 3561 (136-1/4") (240) 616 (24-1/4") (180) 895 (35-1/4") (240) RETURN AIR SUPPLY AIR OUTDOOR AIR (Discharge) OUTDOOR AIR (Economizer) CLEARANCES (mm / in. ) 1 Front 914 / 36 610 / 24 (Less Economizer) 1245 / 49 (With Economizer) 610 / 24 (Less Economizer) Left Side (Filter Access) 1372 / 54 (With Economizer) Right Side (Outdoor Coil) 914 / 36 0/0 Below Unit2 1829 / 72 with 914 / 36 maximum Horizontal Overhang Above Unit3 (For Outdoor Air Discharge) All dimensions are in millimeters and inches, unless otherwise specified. They are subject to change without notice. Certified dimensions will be provided upon request. Back UTILITIES ENTRY DATA HOLE 1 Locate unit so that the vent air outlet hoods are at least: • 0.9 meter (3 ft) above any forced air inlet located within 3.0m (10 ft) horizontal (excluding those integral to the unit). • 1.2 meters (4 ft) below, 1.2m (4 ft.) horizontal from, or 0.31m(1 ft) above any door or gravity air inlet into the building. • 1.2 meters (4 ft) from electric meters, gas meters, regulators and relief equipment. 2 Units may be installed on combustible surfaces capable of continuous exposure to temperatures of 92°C (197°F), and intermittent exposure to temperatures of 124°C (255°F). 3 Units must be installed outdoors. Overhanging structures or shrubs should not obstruct the outdoor air discharge outlet. NOTE: A 25mm (1 in.) clearance must be provided between any combustible material and the supply air ductwork for a distance of 0.9m (3 ft) from the unit. The products of combustion must not be allowed to accumulate within a confined space and recirculate. 16 A B C D OPENING DIAMETER* (in. / mm) 1-1/8 / 29 KO 3/4 NPS / 19 (Fem.) 3-5/8 / 92 KO 3 NPS / 76 (Fem.) 2-3/8 / 60 KO 1-11/16 / 43 Hole USED FOR Control Wiring Power Wiring Front Bottom Front Bottom Gas Piping (Front) Gas Piping (Bottom)** *KO denotes Knockout facility. **Opening in the bottom of the unit can be located by the slice in the insulation. Unitary Products Group 530.26-TG3YI UNIT DIMENSIONS - D*CE / D*CG180 & 240 UNITS (Cont’d.) DUCT COVERS - Units are shipped with the bottom duct openings covered. An accessory flange kit is available for connecting side ducts. For downflow duct applications: 1. Remove the side panels from the supply and return air compartments to gain access to the bottom supply and return air duct covers. 2. Remove and discard the bottom duct covers. 3. Replace the side supply and return air compartment panels. For sideflow duct applications; 1. Replace the side panels on the supply and return air compartments with the accessory flange kit panels. 2. Connect ductwork to the duct flanges on the rear of the unit. 727 (28-5/8") (180) 1006 (39-5/8") (240) DETAIL “X” ACCESSORY SIDE SUPPLY AND RETURN AIR DUCT OPENINGS 397 155⁄8“ 610 (24") (180) 889 (35") (240) DETAIL “Y” UNIT WITH ECONOMIZER AND FIXED OUTDOOR AIR HOODS OUTDOOR COIL END OF UNIT 2337 (92") 1524 (60") 1143 (45") 3181 (125-1/4") (180) 3461 (136-1/4") (240) CENTER OF GRAVITY Unitary Products Group 17 530.26-TG3YI ROOF CURB DIMENSIONS - D*CE / D*CG180 & 240 UNITS 362 (14-1/4") (180) 641 (25-1/4") (240) 2927 (115-1/4") (180) 3207 (126-1/4") (240) * Supply and Return Air (including duct suppport rails) as shown, are typical for downflow duct applications. For location of sideflow duct applications (on back of unit), refer to Unit Dimension details. ROOF CURB BENEFITS UNIT AND CURB APPLICATION 2927 (115-1/4") (180) 3207 (126-1/4") (240) TYPICAL APPLICATIONS 18 Unitary Products Group 530.26-TG3YI TYPICAL APPLICATIONS - Cont’d. ROOF-TOP INSTALLATION (GAS/ELECTRIC UNIT SHOWN) Unitary Products Group 19 P.O. Box 1592, York, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in U.S.A Copyright by York International Corporation 1994. All Rights Reserved. 530.26TG3YI Supersedes: Nothing
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.1 Linearized : No Create Date : 1996:10:24 11:46:03 Producer : Acrobat Distiller 2.0 for Windows Modify Date : 1996:10:25 08:29:35 Page Count : 20 Page Mode : UseThumbsEXIF Metadata provided by EXIF.tools