York Yd Millennium Technical Guide
2015-09-09
: York Yd-Millennium-Technical-Guide york-yd-millennium-technical-guide-811926 york pdf
Open the PDF directly: View PDF .
Page Count: 24
Download | ![]() |
Open PDF In Browser | View PDF |
628770-YTG-C-0712 ® Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage and/or shipping. The compact design, clean styling, low silhouette, and quiet operation make these condensing units suitable for almost any outdoor location. On rooftops . . . because they weigh much less than a single package unit of similar capacity and are much easier to rig and support. At ground level . . . because their ample sub-cooling capacity allows them to be located three or more stories below the evaporator coil. TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & 600 30 THRU 50 NOMINAL TONS Every condenser coil is pressurized with air to 325 psig and leak tested under water. After assembly, the unit is pressurized with a combination of Refrigerant R-410A and nitrogen to 450 psig for pressure testing and additional leak testing. During this pressure test, the operation of the high pressure control is checked. As the unit is being evacuated and dehydrated, the operation of the low pressure control is checked. Every compressor, condenser fan motor, crankcase heater, and electrical control circuit is checked to assure a trouble-free startup and years of reliable operation. The condenser fan guards are vinyl-coated to provide additional rust protection and to enhance the appearance of the unit. Compressors are mounted on rubber isolators to reduce the transmission of vibration. Vertical discharge condenser fans direct sound upward and away from any surrounding structures. All sheet metal parts are constructed of commercial grade galvanized steel. After fabrication, each part is thoroughly cleaned to remove any grease or dirt from its surfaces. The external parts are coated with a powder paint to assure a quality finish for many years. This UL approved coating system has passed the 1000 hour, 20% salt spray test per ASTM Standard B117. All models include a 1-year limited warranty on the complete unit. An additional 4-year extended compressor warranty is available as an option on all models. A matching line of Evaporator Blower units is also offered to meet your precise capacity and air handling requirements. ISO 9001 Certified Quality Management System 628770-YTG-C-0712 Table of Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Condensing Unit Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Guide Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Physical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Unit Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Cooling Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Capacity Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Sound Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Typical Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Typical Field Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Weight And Dimension’s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 2 Unitary Products Group 628770-YTG-C-0712 Product Nomenclature Configured Split Condenser Model Number Nomenclature Y D 360 C00 A 2 A AA 2 A Product Style A = Style A Product Category Y = Split System, Condenser, AC, R-410A Product Generation 1 = First Generation Product Identifier D = Standard Efficiency, 4-Pipe, R-410A Nominal Cooling Capacity - MBH 360 = 30 Ton 480 = 40 Ton 600 = 50 Ton Product Options Installation Options AA = None TA = Technicoat Condenser Coil A = None B = Option 1 Options 1 = Disconnect Voltage Heat Type & Nominal Heat Capacity C00 = Cooling Only 2 = 208/230-3-60 4 = 460-3-60 5 = 575-3-60 Airflow A = Standard Motor Unitary Products Group 3 628770-YTG-C-0712 Condensing Unit Features and Benefits • Capacity staging for more economical operation and more even temperature levels within the conditioned space. • A lockout circuit to prevent the unit from cycling on safety control. Condenser coils are constructed of copper tubes and aluminum fins for durability and long lasting efficient operation. • Pump-out on unit startup to prevent liquid refrigerant returning to the compressor is standard on all models. • Inherently protected condenser fan motors. • Crankcase heaters that will be de-energized when the compressor is operating. • V-Coil Design with exterior service port connections. • Both high and low pressure controls. Since these controls are self-contained, there are no capillary lines to be damaged. • Five-minute anti-short cycle timer and minimum compressor run time. • Factory installed disconnect and Technicoat coils option. • Self contained high and low pressure controls. • Meets or exceeds ASHRAE 90.1 standards. • Scroll compressors provide both high efficiency and reliability. • Simplicity ® Controls • Dual refrigerant circuits. • • Solid state or internal line break compressor motor protection. • Class 2, 24-volt thermostat control circuit. • Factory installed service valves are standard. • Low ambient VFD control to 0° F. • Two filter-driers are shipped in the unit's control box for field installation in the liquid line near the condensing unit. • Phase Monitors - Designed to prevent unit damage. The phase monitor will shut the unit down and out-of phase condition. • Copper stub-outs are factory mounted on the suction and liquid line service valves to simplify the field piping connections. • Hot Gas Bypass Kit - That will provide a metered flow of compressor discharge gas to the system’s evaporator coil during reduced load operation. • Optional skid for fork truck handling (requires 96” length forks). • 4 Multiple controls to provide stable system operation at ambient temperatures down to 40ºF with kits available for operation to 0ºF. Condensing Unit Accessories Unitary Products Group 628770-YTG-C-0712 Guide Specifications THE DIMENSIONS OF EACH UNIT SHALL: SPLIT SYSTEM COOLING ONLY CONDENSING UNITS MODELS YD360, YD480 AND YD600 • EACH COMPRESSOR SHALL: • THE INSTALLER SHALL: • • Furnish York ® air-cooled condensing units or equivalent in accordance with the performance schedule shown on the plans, and Install each unit as shown on the plans in accordance with: • The manufacturers recommendations and • All applicable national and local codes EACH UNIT SHALL BE: Not exceed those specified on the plans. Be mounted on isolators to minimize the transmission of vibration. ALL CONDENSER COILS SHALL: • Be draw through design. • Be constructed of copper tubes arranged in staggered rows and mechanically expanded into aluminum fins. THE CONDENSER FAN MOTOR(S) SHALL: • Be directly connected to the condenser fans. • Have permanently lubricated ball bearings. • Have inherent overload protection. • CSA approved. • Motors shall be three phase. • Completely assembled for one-piece shipping and rigging. • The propeller-type condenser fans shall be arranged for vertical discharge of the condenser air. • Leak pressure and functionally tested at the factory to assure a trouble-free start-up after installation. THE WIRING FOR EACH UNIT SHALL INCLUDE: • Covered by a 1-year limited parts warranty on the complete unit. • In current production with published literature available to check performance, limitations, specifications, power requirements, dimensions, operation and appearance. • A crankcase heater (one per compressor) • All 24-volt temperature control circuit. • Both high and low pressure cutouts. • Solid-state or internal line break compressor motor protection. • Condenser fan motor control to assure stable operation at ambient temperatures down to 40ºF. EACH UNIT SHALL HAVE: • A steel angle frame to provide the rigid support required for shipping, rigging and years of dependable operation. • Zinc-coated steel that has been finished by a powder paint process to provide a long lasting, quality appearance. • THE REFRIGERANT PIPING of each system shall include: • A filter-drier shipped for field installation. Removable panels for easy access to all internal components during maintenance and service. Unitary Products Group 5 628770-YTG-C-0712 Physical Data YD360 thru 600 Physical Data Component Nominal Tonnage REFRIGERANT Refrigerant type Holding charge (lb)1 Operating Charge (lb)2 System #1 System #2 YD360 30 Models YD480 40 YD600 50 R-410A 1.0 35.0 35.0 R-410A 1.0 47.0 47.0 R-410A 1.0 51.0 51.0 128.5 88.5 37.5 128.5 88.5 57.7 128.5 88.5 57.7 1875 1895 2315 2347 2345 2381 DIMENSIONS (inches) Length Width Height WEIGHTS (lb) Shipping Operating COMPRESSORS Type Quantity Cooling Nominal Capacity (Tons) Capacity Stages SYSTEM DATA No. Refrigeration Circuits Suction Line OD (in.) Liquid Line OD (in.) OUTDOOR COIL DATA Face area (Sq. Ft.) Tandem Scroll Tandem Scroll Tandem Scroll 2 2 2 System #1 System #2 System #1 System #2 System #1 System #2 Rows Fins per inch Tube diameter (in.) Circuitry Type Refrigerant Control CONDENSER FAN DATA No. Fans / Diameter (in.) Type Drive type No. speeds Number of motors System #1 System #2 Motor HP (ea.) Rotation3 RPM Nominal CFM 1 2 3 6 System #1 System #2 15 15 2 2 20 20 2 2 25 25 2 2 2 1 5/8 7/8 2 1 5/8 7/8 2 1 5/8 7/8 32.5 32.5 2 16 3/8 Interlaced --- 45.5 45.5 2 16 3/8 Interlaced --- 52.0 52.0 2 16 3/8 Interlaced --- 4/30 Axial Direct 1 2 2 1 1/2 CW 1140 15400 15400 4/30 Axial Direct 1 2 2 1 1/2 CW 1140 19400 19400 4/30 Axial Direct 1 2 2 1 1/2 CW 1140 19900 19900 Holding Charge is the amount in the unit as shipped from the factory. Includes matched evaporator unit with 25 ft of piping. When viewing the shaft end of the motor. Unitary Products Group 628770-YTG-C-0712 Unit Limitations Condenser Unit limitations Model Nominal Tonnage YD360 30 YD480 40 YD600 50 Unit Voltage 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 Applied Voltage1 Max Min2 187 432 540 187 432 540 187 432 540 252 504 630 252 504 630 252 504 630 Outdoor DB Temp Cooling (°F) Indoor DB Temp Cooling (°F) Max Min† Max Min 125 40 86 68 125 40 86 68 125 40 86 68 1 Rated in accordance with AHRI Standard 110, Range “A” Utilization Voltage. 2 Low Ambient accessories are available to permit stable system operation at ambient temperatures down to 0°F. Cooling Ratings Cooling Ratings System Cooling Capacity1 Condensing Unit Only Outdoor Unit Indoor Unit Gross Capacity2 (MBH) kW EER YD360 333 29.9 11.1 YD480 469 37.4 12.5 YD600 576 50.0 11.5 Rated Airflow (CFM) Gross Capacity3 (MBH) EER IEER ND360 375 10.0 11.1 12,000 ND480 500 10.0 10.8 16,000 ND600 620 10.0 10.4 17,500 1 Testing in accordance with the Unitary Large Equipment certification program, which is based on AHRI Standard 340/360. 2 Condensing unit only ratings are at 45 F SST and 95 F entering-air temperature. 3 Deduct 1 MBH when a unit operates at 208 volts. EER = Energy Efficiency Ratio at full load - the cooling capacity in Btu’s per hour (Btuh) divided by the power input in watts, expressed in Btuh per watt (Btuh/watt). EER; condensing unit only ratings based on 45º F SST and 95ºF entering outdoor air temperature. IEER - A single number cooling part-load efficiency figure that is calculated based on equipment stages and EER at these capacity stages (ANSI/ AHRI STD 340/360 - 2007) LEGEND EER = Energy Efficiency Ratio SST = Saturated Suction Temperature AHRI = Air Conditioning and Refrigeration Institute IEER = Integrated Energy Efficiency Ratio Unitary Products Group 7 628770-YTG-C-0712 Capacity Performance Condenser and Air Handling Cooling Capacities YD360/ND360 (30 Ton) Air on Evaporator Coil CFM 9000 10500 12000 13500 15000 9000 10500 12000 13500 15000 8 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 440.3 411.6 382.9 318.5 347.4 454.2 424.6 394.9 328.6 358.3 468.1 437.5 407.0 338.6 369.3 448.4 417.1 347.0 378.4 459.3 427.2 355.5 387.6 26.1 25.5 24.9 24.4 24.2 26.4 25.8 25.2 24.6 24.4 26.7 26.1 25.4 24.9 24.7 26.2 25.5 25.0 24.8 26.3 25.7 25.1 24.9 221.9 272.6 323.2 318.5 347.4 247.9 301.8 355.6 328.6 358.3 274.0 331.0 388.0 338.6 369.3 338.1 399.7 347.0 378.4 345.3 411.4 355.5 387.6 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 409.2 381.4 353.7 303.9 323.6 421.5 392.9 364.3 313.1 333.4 433.9 404.4 375.0 322.3 343.2 412.3 382.3 328.6 349.9 420.2 389.7 334.9 356.6 30.9 30.4 30.0 29.5 29.4 31.1 30.6 30.2 29.7 29.6 31.3 30.9 30.4 29.9 29.8 31.0 30.5 30.0 29.9 31.0 30.6 30.1 29.9 208.5 258.1 307.7 303.9 323.6 224.6 277.4 330.2 313.1 333.4 240.8 296.7 352.7 322.3 343.2 313.9 371.2 328.6 349.9 331.0 389.7 334.9 356.6 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Capacity1 Input Return Dry Bulb (°F) (MBh) (kW)2 85 80 75 70 65 75°F 185.2 148.6 424.8 28.5 235.9 199.2 162.5 396.5 28.0 286.6 249.9 213.2 176.5 368.3 27.5 301.8 265.1 228.4 191.8 155.1 311.2 26.9 347.4 312.7 276.0 239.3 202.7 335.5 26.8 202.9 157.8 437.9 28.7 256.7 211.7 166.6 408.7 28.2 310.6 265.5 220.5 175.4 379.6 27.7 320.2 281.7 238.2 191.6 146.6 320.8 27.2 358.3 332.3 290.0 242.2 197.1 345.9 27.0 220.6 167.1 451.0 29.0 277.6 224.1 170.7 421.0 28.5 334.6 281.1 227.7 174.3 391.0 27.9 338.6 298.3 248.0 191.5 138.1 330.4 27.4 369.3 351.8 303.9 245.0 191.6 356.2 27.2 287.0 235.8 184.6 430.4 28.6 346.9 295.7 244.5 193.3 399.7 28.0 347.0 313.7 264.1 211.4 160.2 337.8 27.5 378.4 369.7 321.3 267.3 216.1 364.1 27.3 296.3 247.4 198.4 439.7 28.7 359.3 310.3 261.3 212.3 408.4 28.1 355.5 329.2 280.2 231.2 182.3 345.2 27.6 387.6 387.6 338.6 289.6 240.7 372.1 27.4 95°F 172.7 137.0 388.6 34.2 222.4 186.6 150.9 362.5 33.7 272.0 236.2 200.5 164.8 336.3 33.2 298.8 263.1 227.3 191.6 155.8 295.7 32.8 323.6 297.2 261.4 225.7 189.9 309.1 32.7 185.1 145.7 400.6 34.3 237.9 198.5 159.0 373.6 33.9 290.7 251.2 211.8 172.3 346.6 33.4 310.6 279.8 238.8 200.8 161.3 304.8 33.0 333.4 316.1 273.8 237.1 197.6 318.6 32.9 197.6 154.4 412.5 34.5 253.5 210.3 167.1 384.7 34.0 309.5 266.3 223.0 179.8 357.0 33.6 322.3 296.5 250.2 210.1 166.8 313.9 33.1 343.2 334.9 286.2 248.5 205.3 328.1 33.1 267.6 221.3 175.1 384.1 34.2 326.5 280.2 234.0 187.7 356.4 33.8 328.6 312.1 264.2 219.5 173.3 313.2 33.3 349.9 345.7 296.7 253.2 206.9 327.6 33.3 281.7 232.4 183.1 383.5 34.4 343.5 294.2 244.9 195.6 355.8 34.0 334.9 327.6 278.3 229.0 179.7 312.5 33.5 356.6 356.6 307.3 257.9 208.6 327.0 33.5 90 215.2 265.3 315.5 311.2 335.5 236.3 289.6 342.9 320.8 345.9 257.4 313.9 370.3 330.4 356.2 326.0 385.4 337.8 364.1 338.2 400.5 345.2 372.1 199.2 248.3 297.4 295.7 309.1 223.8 272.7 321.6 304.8 318.6 248.5 297.2 345.8 313.9 328.1 311.6 350.8 313.2 327.6 326.1 355.8 312.5 327.0 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 179.0 142.8 229.1 192.9 156.7 279.3 243.1 206.8 170.6 300.3 264.1 227.9 191.7 335.5 304.9 268.7 232.5 194.0 151.8 247.3 205.1 162.8 300.6 258.4 216.1 173.9 315.4 280.7 238.5 196.2 345.9 324.2 281.9 239.6 209.1 160.8 265.5 217.2 168.9 322.0 273.7 225.4 177.1 330.4 297.4 249.1 200.8 356.2 343.4 295.1 246.7 277.3 228.5 179.8 336.7 288.0 239.2 190.5 337.8 312.9 264.2 215.4 364.1 357.7 309.0 260.3 289.0 239.9 190.7 351.4 302.2 253.1 203.9 345.2 328.4 279.3 230.1 372.1 372.1 322.9 273.8 105°F 164.5 129.8 213.6 178.9 144.2 262.7 228.0 193.3 158.6 293.1 262.5 227.8 193.1 309.1 286.3 251.6 216.9 179.3 138.3 231.7 190.7 149.6 284.0 243.0 202.0 160.9 303.5 279.8 238.0 197.8 318.6 305.2 262.8 223.1 194.2 146.9 249.8 202.4 155.1 305.4 258.0 210.7 163.3 313.9 297.2 248.3 202.4 328.1 324.0 273.9 229.3 263.0 214.5 165.9 319.0 273.4 224.8 176.2 313.2 303.0 253.7 205.9 327.6 325.5 275.5 228.4 276.3 226.5 176.7 332.7 288.7 239.0 189.2 312.5 308.9 259.1 209.3 327.0 327.0 277.2 227.4 65 155.5 196.3 154.0 197.4 152.4 198.4 166.7 211.5 181.0 224.7 158.4 182.2 156.8 182.1 155.1 181.9 157.3 179.8 159.5 177.6 Unitary Products Group 628770-YTG-C-0712 YD360/ND360 (30 Ton) (Continued) Air on Evaporator Coil CFM 9000 10500 12000 13500 15000 1 2 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 368.1 343.5 318.9 287.4 294.6 379.6 354.3 328.9 296.4 303.9 391.2 365.1 338.9 305.5 313.1 355.9 330.4 297.8 305.2 346.7 321.9 290.1 297.4 37.4 37.0 36.5 36.1 36.1 37.5 37.1 36.6 36.3 36.2 37.6 37.2 36.7 36.4 36.4 37.5 37.0 36.7 36.7 37.8 37.3 37.0 37.0 189.9 238.5 287.0 287.4 294.6 223.1 268.0 313.0 296.4 303.9 256.2 297.6 338.9 305.5 313.1 309.4 330.4 297.8 305.2 321.1 321.9 290.1 297.4 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 156.2 122.6 347.5 40.7 204.8 171.2 137.5 324.5 40.2 253.4 219.7 186.1 152.4 301.5 39.7 287.4 262.0 228.3 194.7 161.0 279.1 39.5 294.6 275.4 241.8 208.1 174.5 280.1 39.5 173.6 131.0 358.7 40.7 225.4 182.9 140.3 335.0 40.3 277.3 234.8 192.2 149.6 311.2 39.8 296.4 279.9 237.3 194.7 152.2 288.1 39.5 303.9 294.3 251.7 209.1 166.5 289.1 39.6 190.9 139.4 369.9 40.8 246.1 194.6 143.1 345.4 40.3 301.3 249.8 198.3 146.8 320.9 39.9 305.5 297.8 246.3 194.8 143.3 297.1 39.6 313.1 313.1 261.6 210.1 158.6 298.1 39.7 258.5 207.6 156.7 327.7 40.8 311.6 266.5 215.7 164.8 304.5 40.3 297.8 294.0 243.1 192.2 141.4 282.4 40.0 305.2 305.2 254.4 203.5 152.6 282.9 40.1 270.9 220.7 170.4 310.0 41.2 321.9 283.3 233.0 182.8 288.0 40.7 290.1 290.1 239.9 189.6 139.4 267.7 40.4 297.4 297.4 247.1 196.9 146.7 267.8 40.5 90 180.6 228.6 276.7 279.1 280.1 222.3 263.3 304.4 288.1 289.1 264.0 298.0 320.9 297.1 298.1 307.1 304.5 282.4 282.9 310.0 288.0 267.7 267.8 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 148.0 115.4 196.0 163.4 130.8 244.1 211.5 178.9 146.3 279.1 261.4 228.8 196.2 280.1 264.5 231.9 199.3 167.8 123.6 219.2 175.1 131.0 270.6 226.5 182.4 138.3 288.1 280.0 236.6 191.7 289.1 283.4 240.6 195.1 187.5 131.9 242.4 186.7 131.1 297.2 241.6 185.9 130.3 297.1 297.1 244.4 187.2 298.1 298.1 249.3 190.9 253.9 200.8 147.6 304.2 259.7 206.5 153.3 282.4 282.4 232.5 178.6 282.9 282.9 233.2 178.6 265.5 214.8 164.1 288.0 277.8 227.1 176.4 267.7 267.7 220.7 170.0 267.8 267.8 217.1 166.4 65 163.6 166.7 147.6 151.0 131.6 135.3 125.4 125.5 119.3 115.7 These capacities are gross ratings. For net capacity, deduct supply air blower motor, MBh. Example: Refer to the appropriate Blower Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746 nameplate rated motor efficiency. These ratings include the condenser fan motors and the compressor motors but not the supply air blower motor. Unitary Products Group 9 628770-YTG-C-0712 YD480/ND480 (40 Ton) Air on Evaporator Coil CFM 12000 14000 16000 18000 20000 12000 14000 16000 18000 20000 10 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 579.6 530.4 481.2 451.0 448.9 600.7 549.4 498.0 466.9 464.9 621.8 568.3 514.9 482.8 481.0 583.2 528.6 495.6 493.6 598.1 542.3 508.4 506.2 32.8 31.6 30.3 30.3 29.6 32.8 31.5 30.3 30.3 29.5 32.8 31.5 30.3 30.2 29.5 32.0 30.8 30.7 30.0 32.5 31.3 31.2 30.5 292.9 355.0 417.1 455.0 448.9 308.8 372.5 436.1 468.9 464.9 324.8 390.0 455.2 482.8 481.0 421.4 498.7 495.6 493.6 452.8 542.3 508.4 506.2 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 481.4 462.7 443.9 407.8 393.7 511.8 491.9 472.0 433.6 418.5 542.2 521.1 500.0 459.3 443.4 525.6 504.3 463.3 447.2 530.1 508.6 467.2 451.0 37.4 37.3 37.1 36.1 36.5 37.9 37.7 37.6 36.5 37.0 38.3 38.2 38.1 37.0 37.4 38.1 37.9 36.9 37.3 37.9 37.8 36.7 37.1 244.5 311.0 377.5 403.8 393.7 275.6 349.6 423.5 431.5 418.5 306.8 388.2 469.6 459.3 443.4 417.7 489.1 463.3 447.2 447.2 508.6 467.2 451.0 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 247.9 202.9 530.5 35.1 310.0 265.0 220.0 496.5 34.4 372.1 327.1 282.2 237.2 462.6 33.7 418.2 373.2 328.2 283.2 238.2 429.4 33.2 448.9 437.7 392.7 347.7 302.7 421.3 33.0 259.6 210.4 556.3 35.3 323.3 274.1 224.9 520.6 34.6 386.9 337.7 288.5 239.3 485.0 34.0 435.1 385.9 337.8 287.4 238.2 450.2 33.4 464.9 453.3 406.6 354.9 305.7 441.7 33.2 271.4 217.9 582.0 35.6 336.6 283.1 229.7 544.7 34.9 401.7 348.3 294.9 241.4 507.4 34.2 452.0 398.5 347.3 291.7 238.2 471.1 33.6 481.0 468.9 420.5 362.1 308.6 462.2 33.5 367.3 313.2 259.1 554.4 35.0 439.6 385.5 331.4 277.3 516.5 34.4 480.2 440.9 387.9 332.7 278.6 479.4 33.8 493.6 487.6 435.9 379.4 325.3 470.4 33.6 398.0 343.3 288.5 564.1 35.2 477.4 422.6 367.9 313.1 525.5 34.5 508.4 483.2 428.5 373.7 318.9 487.8 33.9 506.2 506.2 451.4 396.7 341.9 478.6 33.8 95°F 200.7 156.9 462.2 41.8 267.2 223.4 179.6 446.3 41.6 333.7 289.9 246.1 202.3 430.4 41.4 360.0 316.2 272.4 228.6 184.8 405.5 40.9 393.7 353.0 309.2 265.4 221.6 382.2 41.0 225.1 174.5 487.2 42.1 299.0 248.5 197.9 470.4 41.8 373.0 322.4 271.9 221.3 453.7 41.6 402.2 351.7 300.0 250.6 200.0 427.3 41.1 418.5 392.7 339.6 291.6 241.0 402.8 41.2 249.5 192.2 512.1 42.3 330.9 273.6 216.3 494.5 42.1 412.3 355.0 297.7 240.4 476.9 41.8 444.5 387.2 327.6 272.6 215.3 449.1 41.4 443.4 432.3 370.0 317.7 260.4 423.4 41.4 357.6 297.5 237.4 497.0 42.1 446.1 386.0 325.9 265.9 479.3 41.8 455.9 421.1 359.8 300.9 240.8 451.3 41.4 447.2 441.7 379.1 321.5 261.4 425.6 41.4 384.3 321.4 258.5 499.5 42.1 480.0 417.1 354.2 291.3 481.7 41.8 467.2 454.9 392.0 329.2 266.3 453.5 41.3 451.0 451.0 388.2 325.3 262.4 427.7 41.4 90 268.7 333.0 397.3 429.4 421.3 292.2 361.0 429.8 450.2 441.7 315.8 389.1 462.4 471.1 462.2 419.5 493.9 479.4 470.4 450.0 525.5 487.8 478.6 256.0 315.8 375.6 403.5 382.2 293.1 355.9 418.7 426.3 402.8 330.2 395.9 461.7 449.1 423.4 415.9 471.7 451.3 425.6 435.9 481.7 453.5 427.7 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 224.3 179.9 288.6 244.2 199.8 352.9 308.5 264.1 219.7 389.1 344.7 300.3 255.9 421.3 395.3 351.0 306.6 242.4 192.5 311.2 261.3 211.4 380.0 330.1 280.2 230.3 418.7 368.8 318.9 269.0 441.7 423.0 373.1 323.2 260.4 205.1 333.7 278.4 223.0 407.0 351.6 296.3 240.9 448.2 392.9 337.5 282.1 462.2 450.6 395.2 339.9 362.4 305.3 248.3 442.9 385.8 328.7 271.6 468.0 431.0 373.9 316.8 470.4 464.6 407.5 350.4 391.2 332.3 273.5 478.7 419.9 361.0 302.2 487.8 469.1 410.3 351.4 478.6 478.6 419.8 361.0 105°F 212.6 169.1 272.4 229.0 185.5 332.2 288.8 245.4 201.9 363.1 319.7 276.2 232.8 382.2 345.7 302.2 258.8 237.7 185.2 303.4 250.8 198.3 369.0 316.5 264.0 211.5 402.4 350.3 297.2 245.2 402.8 378.9 325.2 273.9 262.8 201.2 334.3 272.7 211.1 405.8 344.2 282.6 221.0 441.7 380.9 318.2 257.7 423.4 412.2 348.1 289.0 352.5 289.0 225.5 428.5 365.1 301.6 238.1 447.6 403.8 339.7 276.8 425.6 420.0 355.3 293.0 370.6 305.3 240.0 451.2 385.9 320.6 255.2 453.5 426.7 361.3 296.0 427.7 427.7 362.4 297.0 65 211.5 262.2 219.1 273.3 226.7 284.5 259.7 293.3 292.6 302.1 189.4 215.4 192.7 221.4 196.1 227.4 213.4 229.6 230.7 231.7 Unitary Products Group 628770-YTG-C-0712 YD480/ND480 (40 Ton) (Continued) Air on Evaporator Coil CFM 12000 14000 16000 18000 20000 1 2 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 443.0 430.0 416.9 403.3 370.8 462.5 448.9 435.3 421.1 387.1 482.1 467.9 453.7 438.8 403.5 468.4 454.2 439.3 403.9 469.0 454.8 439.8 404.4 46.3 46.0 45.6 45.7 45.5 46.3 45.9 45.6 45.7 45.5 46.3 45.9 45.6 45.7 45.5 46.1 45.7 45.9 45.6 46.2 45.9 46.0 45.8 267.5 320.6 373.8 403.3 370.8 310.5 362.1 413.8 421.1 387.1 353.6 403.6 453.7 438.8 403.5 414.2 454.2 439.3 403.9 424.7 454.8 439.8 404.4 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 224.4 181.3 423.8 50.8 277.6 234.5 191.5 413.6 50.3 330.7 287.7 244.6 201.6 403.4 49.8 366.2 323.1 280.1 237.0 193.9 401.0 50.6 370.8 338.3 295.2 252.2 209.1 359.3 50.0 250.3 195.8 437.9 50.5 307.7 253.2 198.7 427.4 50.0 365.1 310.6 256.1 201.6 417.0 49.6 402.5 348.8 294.4 239.9 185.4 414.8 50.3 387.1 365.2 310.8 256.3 201.8 371.4 49.8 276.1 210.2 452.0 50.2 337.7 271.9 206.0 441.3 49.8 399.4 333.5 267.6 201.7 430.6 49.3 438.8 374.6 308.7 242.8 176.9 428.6 50.1 403.5 392.2 326.3 260.4 194.5 383.5 49.5 347.3 280.5 213.7 439.8 50.1 410.9 344.1 277.3 210.4 429.2 49.6 439.3 386.5 319.6 252.8 186.0 427.4 50.4 403.9 398.3 331.4 264.6 197.8 382.3 49.8 356.9 289.1 221.4 438.4 50.4 422.5 354.7 286.9 219.1 427.8 49.9 439.8 398.4 330.6 262.8 195.0 426.1 50.6 404.4 404.4 336.6 268.8 201.0 381.1 50.1 90 278.9 325.5 372.0 401.0 359.3 328.0 368.4 408.9 414.8 371.4 377.0 411.4 430.6 428.6 383.5 412.4 429.2 427.4 382.3 413.5 427.8 426.1 381.1 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 236.2 193.6 282.8 240.1 197.4 329.3 286.6 243.9 201.2 369.3 326.6 283.9 241.2 359.3 331.0 288.3 245.6 262.8 206.4 312.0 255.5 199.1 361.1 304.7 248.2 191.8 402.6 347.4 291.5 234.5 371.4 351.5 296.3 238.6 289.4 219.2 341.2 271.0 200.8 392.9 322.7 252.5 182.3 428.6 368.2 299.2 227.8 383.5 372.1 304.4 231.7 342.2 272.0 201.8 393.3 323.1 252.9 182.7 427.4 369.2 299.5 228.8 382.3 376.6 307.6 236.2 343.2 273.0 202.8 393.8 323.5 253.3 183.1 426.1 370.1 299.9 229.7 381.1 381.1 310.8 240.6 65 198.5 202.9 178.1 182.2 157.7 161.5 158.5 165.9 159.4 170.3 These capacities are gross ratings. For net capacity, deduct supply air blower motor, MBh. Example: Refer to the appropriate Blower Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746 nameplate rated motor efficiency. These ratings include the condenser fan motors and the compressor motors but not the supply air blower motor. Unitary Products Group 11 628770-YTG-C-0712 YD600/ND600 Air Handler with M1CZ600A Evaporator Coil (50 Ton) Air on Evaporator Coil CFM 15000 17500 20000 21750 23500 15000 17500 20000 21750 23500 12 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 778.4 711.3 644.1 618.5 629.2 803.9 734.5 665.2 638.8 649.9 829.3 757.8 686.3 659.1 670.6 784.2 710.3 682.2 694.3 810.6 734.3 705.3 717.9 38.3 40.7 43.1 41.7 40.1 38.1 40.5 42.9 41.5 39.9 37.9 40.3 42.7 41.2 39.7 39.9 42.3 40.8 39.3 39.5 41.9 40.5 38.9 415.3 471.4 527.5 618.5 629.2 456.4 517.4 578.5 638.8 649.9 497.4 563.4 629.5 659.1 670.6 617.2 681.9 682.2 694.3 671.0 734.3 705.3 717.9 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 700.8 647.9 595.0 579.8 603.6 717.9 663.7 609.5 594.0 618.3 735.0 679.5 624.1 608.1 633.1 690.9 634.5 618.3 643.7 702.3 644.9 628.5 654.3 50.7 50.6 50.4 49.5 48.3 51.1 50.9 50.8 49.8 48.7 51.5 51.3 51.2 50.2 49.0 51.1 50.9 49.9 48.8 50.8 50.7 49.7 48.5 394.8 454.7 514.5 579.8 603.6 430.2 494.6 559.0 594.0 618.3 465.6 534.5 603.4 608.1 633.1 560.0 624.1 618.3 643.7 585.6 644.9 628.5 654.3 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 359.0 302.7 739.6 44.5 415.1 358.8 302.5 679.6 45.7 471.2 415.0 358.7 302.4 619.5 46.8 580.0 523.8 467.5 411.2 354.9 599.2 45.6 573.3 517.0 460.7 404.4 348.1 616.4 44.2 392.7 329.1 760.9 44.6 453.8 390.2 326.6 699.1 45.7 514.9 451.3 387.7 324.1 637.4 46.9 619.6 569.5 508.3 442.3 378.7 616.4 45.7 621.9 562.2 501.2 435.0 371.4 634.1 44.3 426.5 355.6 782.2 44.7 492.5 421.6 350.7 718.7 45.8 558.5 487.6 416.7 345.8 655.2 46.9 659.1 615.2 549.1 473.3 402.4 633.6 45.7 670.6 607.4 541.7 465.5 394.6 651.9 44.3 540.1 463.0 386.0 737.6 45.5 612.8 535.7 458.7 381.6 672.4 46.6 682.2 670.1 595.4 515.9 438.8 650.3 45.4 694.3 667.1 592.6 513.0 435.9 669.0 44.0 587.7 504.5 421.2 756.4 45.1 667.1 583.9 500.6 417.4 689.6 46.3 705.3 725.0 641.7 558.5 475.2 666.9 45.1 717.9 726.8 643.6 560.4 477.1 686.1 43.7 95°F 338.4 281.9 643.6 56.8 398.2 341.8 285.3 603.3 56.7 458.1 401.6 345.2 288.7 563.1 56.6 541.3 484.9 428.4 371.9 315.5 542.8 55.9 549.1 492.7 436.2 379.7 323.3 564.5 55.9 366.7 303.3 663.4 56.8 431.1 367.6 304.2 621.9 56.7 495.5 432.0 368.6 305.1 580.5 56.7 574.7 521.6 455.7 394.6 331.2 559.6 56.0 591.1 530.0 463.9 403.0 339.6 581.9 55.9 395.1 324.6 683.2 56.9 464.0 393.5 323.0 640.5 56.8 532.9 462.4 391.9 321.5 597.9 56.7 608.1 558.3 483.0 417.3 346.8 576.4 56.0 633.1 567.2 491.6 426.3 355.8 599.3 56.0 485.7 411.3 337.0 648.5 56.6 557.7 483.4 409.0 334.7 605.3 56.5 618.3 583.6 506.8 434.9 360.6 583.5 55.8 643.7 593.0 516.0 444.3 369.9 606.8 55.8 507.4 429.2 351.0 656.5 56.4 582.5 504.3 426.1 347.9 612.7 56.3 628.5 608.9 530.7 452.5 374.3 590.7 55.6 654.3 618.7 540.5 462.3 384.1 614.2 55.6 90 405.1 463.0 521.0 599.2 616.4 443.3 506.0 568.7 616.4 634.1 481.5 549.0 616.4 633.6 651.9 588.6 653.0 650.3 669.0 628.3 689.6 666.9 686.1 367.7 434.4 501.2 542.8 564.5 416.1 480.2 544.4 559.6 581.9 464.5 526.0 587.6 576.4 599.3 546.8 600.2 583.5 606.8 567.5 612.7 590.7 614.2 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 348.7 292.3 406.7 350.3 293.9 464.7 408.3 351.9 295.5 560.7 504.3 447.9 391.6 561.2 504.8 448.4 392.1 379.7 316.2 442.5 378.9 315.4 505.2 441.6 378.1 314.6 597.1 545.5 482.0 418.4 606.5 546.1 482.5 419.0 410.8 340.1 478.3 407.6 336.9 545.7 475.0 404.3 333.6 633.6 586.7 516.0 445.3 651.9 587.3 516.6 445.9 512.9 437.2 361.5 585.3 509.6 433.8 358.1 650.3 626.8 551.1 475.4 669.0 630.0 554.3 478.6 547.5 466.8 386.1 624.8 544.1 463.4 382.7 666.9 666.9 586.2 505.5 686.1 672.7 592.0 511.3 105°F 311.4 255.1 378.1 321.8 265.5 444.9 388.6 332.3 276.0 508.1 451.8 395.5 339.2 510.2 453.9 397.6 341.3 342.4 277.3 415.1 350.0 284.9 487.8 422.7 357.5 292.4 542.3 491.3 425.0 361.0 554.8 493.5 427.0 363.2 373.4 299.5 452.1 378.1 304.2 530.7 456.8 382.8 308.9 576.4 530.7 454.4 382.8 599.3 533.0 456.5 385.1 470.5 394.3 318.0 552.5 476.2 400.0 323.7 583.5 553.4 476.0 400.9 606.8 555.8 478.3 403.3 488.9 410.4 331.9 574.2 495.7 417.2 338.6 590.7 576.1 497.5 419.0 614.2 578.6 500.0 421.5 65 335.2 335.7 354.9 355.5 374.6 375.2 399.7 402.9 424.8 430.6 282.9 285.0 295.9 298.1 308.9 311.1 324.7 327.1 340.5 343.0 Unitary Products Group 628770-YTG-C-0712 YD600/ND600 Air Handler with M1CZ600A Evaporator Coil (50 Ton) (Continued) Air on Evaporator Coil CFM WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 586.4 558.8 531.1 505.9 525.3 608.8 580.2 551.5 525.2 545.4 631.3 601.5 571.8 544.6 565.5 606.1 576.2 548.7 569.8 610.7 580.5 552.9 574.2 62.8 62.8 62.7 62.3 63.4 62.6 62.5 62.5 62.1 63.2 62.4 62.3 62.3 61.9 63.0 62.2 62.1 61.7 62.8 62.0 61.9 61.5 62.6 340.6 414.2 487.8 505.9 525.3 402.0 465.9 529.8 525.2 545.4 463.4 517.6 571.8 544.6 565.5 533.5 576.2 548.7 569.8 549.4 580.5 552.9 574.2 15000 17500 20000 21750 23500 1 2 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 284.5 228.3 529.2 68.8 358.1 301.9 245.8 514.2 68.8 431.7 375.5 319.4 263.2 499.2 68.9 475.0 418.8 362.7 306.5 250.4 468.9 68.7 471.3 415.2 359.0 302.9 246.7 486.2 70.9 318.1 251.3 554.3 68.3 399.1 332.3 265.5 538.4 68.3 480.1 413.3 346.5 279.7 522.4 68.3 509.8 461.0 394.2 327.4 260.6 490.9 68.2 518.4 457.0 390.2 323.4 256.6 509.0 70.4 351.8 274.3 579.4 67.8 440.2 362.7 285.3 562.6 67.8 528.6 451.2 373.7 296.3 545.7 67.8 544.6 503.2 425.8 348.3 270.9 512.8 67.7 565.5 498.8 421.4 343.9 266.5 531.8 69.9 455.3 377.2 299.0 563.8 67.7 547.3 469.1 390.9 312.8 547.0 67.7 548.7 523.2 445.1 366.9 288.8 514.0 67.6 569.8 518.7 440.5 362.3 284.2 532.9 69.8 470.5 391.6 312.7 565.0 67.6 565.9 487.1 408.2 329.3 548.3 67.6 552.9 543.3 464.4 385.5 306.6 515.1 67.5 574.2 538.5 459.6 380.8 301.9 534.1 69.7 90 313.5 394.0 474.4 468.9 486.2 387.9 451.6 515.2 490.9 509.0 462.4 509.2 545.7 512.8 531.8 520.2 547.0 514.0 532.9 531.3 548.3 515.1 534.1 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 257.5 201.5 338.0 282.0 226.0 418.4 362.5 306.5 250.5 441.8 385.8 329.8 273.8 432.4 376.4 320.4 264.4 293.8 225.3 383.1 314.7 246.2 472.4 404.0 335.5 267.1 477.3 430.7 363.5 293.8 482.1 420.5 353.3 283.6 330.1 249.2 428.3 347.3 266.4 526.4 445.5 364.6 283.7 512.8 475.7 397.1 313.8 531.8 464.6 386.2 302.7 440.2 360.1 280.0 542.0 462.0 381.9 301.8 514.0 493.1 414.2 332.9 532.9 481.5 402.7 321.4 452.0 372.8 293.6 548.3 478.4 399.2 320.0 515.1 510.5 431.2 352.0 534.1 498.4 419.2 340.0 65 217.9 208.5 225.4 215.1 232.9 221.8 252.9 241.3 272.8 260.8 These capacities are gross ratings. For net capacity, deduct supply air blower motor, MBh. Example: Refer to the appropriate Blower Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746 nameplate rated motor efficiency. These ratings include the condenser fan motors and the compressor motors but not the supply air blower motor. Condenser Only Cooling Capacities YD360 thru 600 Condenser Only Capacities Temperature of Air on Condenser Coil, °F Suction Press. & Corresponding MODEL Temp. @ Saturation YD360 YD480 YD600 65 75 85 95 105 115 PSIG °F MBH KW EER MBH KW EER MBH KW EER MBH KW EER MBH KW EER MBH KW EER 104 117 129 142 154 105 117 130 142 155 105 118 130 142 154 35 40 45 50 55 35 40 45 50 55 35 40 45 50 55 275.4 327.9 380.4 432.9 485.4 418.0 461.0 504.0 547.0 590.0 489.4 561.4 633.4 705.4 777.4 28.5 29.2 29.8 30.4 31.0 33.2 34.4 35.6 36.9 38.1 45.3 46.2 47.2 48.2 49.2 9.6 11.2 12.8 14.3 15.7 12.6 13.4 14.1 14.8 15.5 10.8 12.1 13.4 14.6 15.8 264.0 316.0 368.0 420.0 472.0 408.0 451.0 494.0 537.0 580.0 487.2 558.7 630.2 701.7 773.2 27.4 28.1 28.7 29.3 30.0 32.4 33.5 34.6 35.7 36.8 44.1 45.2 46.3 47.4 48.5 9.6 11.3 12.8 14.3 15.8 12.6 13.5 14.3 15.0 15.8 11.0 12.4 13.6 14.8 15.9 250.0 302.0 354.0 406.0 458.0 399.2 441.6 484.1 526.5 569.0 482.6 554.6 626.6 698.6 770.6 26.4 27.0 27.5 28.1 28.7 32.4 33.1 33.8 34.5 35.2 43.4 44.4 45.4 46.4 47.4 9.5 11.2 12.9 14.4 16.0 12.3 13.3 14.3 15.3 16.2 11.1 12.5 13.8 15.1 16.2 238.2 285.8 333.5 381.1 428.8 397.3 433.0 468.8 504.5 540.3 442.2 509.2 576.2 643.2 710.2 28.8 29.4 29.9 30.5 31.0 36.2 36.8 37.4 38.0 38.5 48.4 49.4 50.5 51.3 52.3 8.3 9.7 11.1 12.5 13.8 11.0 11.8 12.5 13.3 14.0 9.1 10.3 11.4 12.5 13.6 231.8 273.0 314.2 355.4 396.6 389.6 419.2 448.9 478.5 508.2 391.3 456.8 522.3 587.8 653.3 32.0 32.5 33.0 33.6 34.1 40.4 40.9 41.3 41.8 42.2 54.4 55.1 55.9 56.6 57.4 7.2 8.4 9.5 10.6 11.6 9.6 10.3 10.9 11.5 12.0 7.2 8.3 9.3 10.4 11.4 228.5 263.3 298.1 332.9 367.7 389.2 410.8 432.4 454.0 475.6 334.0 400.0 466.0 532.0 598.0 35.1 35.6 36.2 36.7 37.2 45.0 45.2 45.4 45.6 45.8 60.7 61.1 61.5 62.0 62.4 7.4 8.2 9.1 9.9 8.6 9.1 9.5 9.9 10.4 5.5 6.5 7.6 8.6 9.6 Unitary Products Group 6.5 13 628770-YTG-C-0712 Sound Performance Outdoor Sound Power Levels (dB), 60 Hz Octave Bands (Hz) Nominal Tonnage dB(A)1 YD360 30 YD480 YD600 Model 1 63 125 250 500 1000 2000 4000 8000 92 90 93 91 89 87 83 79 74 40 92 90 93 91 89 87 84 80 75 50 93 91 94 92 90 87 84 80 75 Rated in accordance with AHRI 270 Standard. Electrical Data YD360 thru 600 Electrical Data Compressors Model YD360 YD480 YD600 14 Power Supply Outdoor Fan Motor Qty FLA (each) Minimum Circuit Ampacity Maximum Fuse Size (A) 1 1/2 4 5.8 129.5 150 1 1/2 4 2.9 63.5 70 575-3-60 1 1/2 4 2.2 47.1 50 225 208/230-3-60 1 1/2 4 5.8 151.1 175 26 114 460-3-60 1 1/2 4 2.9 82.6 90 19 80 575-3-60 1 1/2 4 2.2 60.7 70 48.1 75 245 208/230-3-60 1 1/2 4 5.8 227.6 250 18.6 29 125 460-3-60 1 1/2 4 2.9 90.7 100 14.7 23 100 575-3-60 1 1/2 4 2.2 71.3 80 Qty RLA (each) MCC (each) LRA (each) Power Supply HP 208/230-3-60 4 25.0 39 164 208/230-3-60 460-3-60 4 12.2 19 100 460-3-60 575-3-60 4 9.0 14 78 208/230-3-60 4 30.1 47 460-3-60 4 16.7 575-3-60 4 12.2 208/230-3-60 4 460-3-60 4 575-3-60 4 Unitary Products Group 628770-YTG-C-0712 Typical Wiring Diagrams Typical 208/230 Volt, YD360/480/600 Condensing Unit Wiring Diagram Unitary Products Group 15 628770-YTG-C-0712 Typical Wiring Diagrams Typical 460/575 Volt, YD360/480/600 Condensing Unit Wiring Diagram 16 Unitary Products Group 628770-YTG-C-0712 Typical Field Wiring Diagrams Typical Field Wiring Diagram ND360/480 Evaporator Units, ND600 Air Handler and M1CZ600A Evaporator Coil when Matched with YD360, 480, 600 Condenser NOTE: Typical field wiring when OD unit is matched with ND air handler. When matching condensing unit with models other than ND an additional control transformer is required on the Indoor unit. NOTE: For applications on airhandlers/evaporator DX coils other than ND360-600 certified matchups liquid line solenoids may be required for proper operation and refrigerant system dump out. Typical ND360/480 & M1CZ600A Liquid Line Solenoid Wiring Unitary Products Group 17 628770-YTG-C-0712 Standard Terminal Block on ND360/480 and ND600 with M1CZ600A models. On non ND models isolation relays must be installed to avoid overloading on 75 VA transformer on condensing unit. Primary side of transformer connect to line side of power supply. Primary side of transformer connect to line side of power supply. Non ND units may not include any or all of the components required to wire the unit. Use the diagram as general reference only. Typical Liquid Line Solenoid Wiring 18 Unitary Products Group 628770-YTG-C-0712 Weight And Dimension’s Corner Weights & Center Of Gravity (Inches) Unit Model Unit Weight (Lbs.) Shipping Operation Unit Dimensions (Inches) Length Width A B C D Dim X Dim Y Weight A to B Weight D to C YD360 1875 1895 128.5 88.5 404 537 533 401 55.2 44.1 934 941 YD480 2315 2347 128.5 88.5 486 675 671 483 53.8 44.1 1154 1161 YD600 2345 2381 128.5 88.5 486 693 685 481 53.0 44.0 1166 1179 Corner Weights & Center Of Gravity Unitary Products Group 19 628770-YTG-C-0712 REAR B LEFT A C G H D E RIGHT FRONT F YD Unit Dimensions Unit Dimensions (Inches) Model A B C D E F G H YD360 YD480 YD600 128.5 128.5 128.5 88.5 88.5 88.5 37.5 57.7 57.7 41.8 41.8 41.8 40.0 40.0 40.0 46.1 46.1 46.1 37.1 37.1 37.1 23.6 23.6 23.6 Piping And Electrical Connections Unit Clearances Location Piping connections are made from the rear of the unit. Connections can be made directly to the suction and liquid line service valves. Overhead (Top) Piping can be routed to the unit from the left or right side. Electrical connections for power and control wiring is made from the front of all units, left of the electrical control box access. See piping sizes and electrical knockout details. 1 2 20 Dimensions 1 120” Front access panels 36” Left Side 30” Right Side 30” Rear 24” Bottom2 0” Units must be installed outdoors. Overhanging structures or shrubs should not obstruct condenser air discharge. Adequate snow clearance must be provided if winter operation is expected. Unitary Products Group 628770-YTG-C-0712 Piping And Electrical Connection Sizes (30/40/50T) (Inches) Connection Entry Size Suction Line Sys #1 1-5/8 OD Liquid Line Sys #1 7/8 OD Suction Line Sys #2 1-5/8 OD Liquid Line Sys #2 7/8 OD Power Wiring Knockout SEE BELOW Control Wiring 7/8 HOLE Electrical Power Knockout Sizes (Inches) Connection Entry 30-40-50T/230V 30-40-50T/460-575V Power Wiring 2-1/2” 1-1/2” 37.518 10.984 11.385 Liquid (Sys 2) 37.826 Suction (Sys 2) 41.859 Suction (Sys 1) 46.190 Liquid (Sys 1) 50.313 88.140 30 Ton Piping Connections Unitary Products Group 21 628770-YTG-C-0712 57.689 11.385 10.974 37.731 Liquid (Sys 2) 41.934 Suction (Sys 2) 46.206 50.409 Suction (Sys 1) Liquid (Sys 1) 88.140 40 & 50 Ton Piping Connections Control Wiring Power Wiring 37.518 12.878 9.628 SEE DETAIL RIGGING HOLES 19.358 2.313 20.858 2.750 2.500 22.358 5.183 DETAIL RIGGING HOLES SCALE 0.250 88.140 30 Ton Power And Control Wiring Connections 22 Unitary Products Group 628770-YTG-C-0712 Control Wiring Power Wiring 57.689 33.049 29.799 19.358 20.858 22.358 88.140 40 & 50 Ton Power and Control Wiring Connections Unitary Products Group 23 Subject to change without notice. Printed in U.S.A. Copyright © August 1, 2012 by Johnson Controls, Inc. All rights reserved. Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069 628770-YTG-C-0712 Supersedes: 628770-YTG-B-0811
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2000:05:02 13:19:26Z Creator : FrameMaker 10.0.2 Modify Date : 2012:08:01 09:04:10-05:00 Language : en XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/10/03-12:08:50 Creator Tool : FrameMaker 10.0.2 Metadata Date : 2012:08:01 09:04:10-05:00 Producer : Acrobat Distiller 10.1.3 (Windows) Format : application/pdf Title : untitled Document ID : uuid:c4817ea1-4066-49fd-90db-3d9a4c17ba1b Instance ID : uuid:3cd12186-0f6c-4ca2-809b-27d3be380c52 Page Mode : UseOutlines Page Count : 24EXIF Metadata provided by EXIF.tools