USER’S INFORMATION MANUAL
MODELS:
All Residential Multi-position Gas Furnaces
(33” Models)

TABLE OF CONTENTS
CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INSTRUCTIONS FOR EXAMINING THE
FURNACE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
START-UP AND SHUTDOWN INSTRUCTIONS . . . . . . . . . . . . . . . . 3
HOW YOUR GAS FURNACE WORKS . . . . . . . . . . . . . . . . . . . . . . 3
OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
TO TURN OFF THE APPLIANCE . . . . . . . . . . . . . . . . . . . . . . . . . . 4
FURNACE MAINTENANCE - USER INFORMATION . . . . . . . . . . . . 4
EXTERNAL AIR FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

CONTACT INFORMATION
•
•

Go to website at www.york.com, then click on “Contact Us” and
follow the instructions.
Contact us by mail:

We recommend that the user read all sections of this
manual and keep the manual for future reference.

FIRE OR EXPLOSION HAZARD - Failure to follow safety warnings
exactly could result in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
•
•

Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone (including cell phone) in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer,
service agency or the gas supplier.

SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to
alert against unsafe practices and hazards involving only property damage.

Johnson Controls Unitary Products

How to Clean your Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
BLOWER CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
MOTOR LUBRICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SERVICE INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
TROUBLESHOOTING PROBLEMS . . . . . . . . . . . . . . . . . . . . . . . .5
FURNACE CONTROL DIAGNOSTICS . . . . . . . . . . . . . . . . . . . . . .5
FURNACE MAINTENANCE - DEALER/CONTRACTOR . . . . . . . .5
REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Johnson Controls Unitary Products
Consumer Relations
5005 York Drive
Norman, OK 73069

1. The furnace area must be kept clear and free of combustible materials, gasoline and other flammable vapors and liquids.
2. Insulating materials may be combustible. The furnace must be kept
free and clear of insulating materials. The furnace area must be
examined when installed in an attic or other insulated space or
when insulation is added to be sure that the insulation material has
been kept away from the furnace.
3. The furnace needs air for combustion in order to operate properly
and safely. Do not block or obstruct air openings on the furnace, air
openings to the area where the furnace is installed, or spaces
around the furnace.
4. Follow the instructions exactly as shown on the OPERATING
INSTRUCTION LABEL on the furnace or the “START-UP AND
SHUTDOWN INSTRUCTIONS” section of this manual when lighting the furnace or turning the furnace off.
5. Should the gas supply fail to shut off or if overheating occurs, shut
off the gas valve to the furnace before shutting off the electrical supply.
6. Do not use this furnace if any part has been under water. A flooddamaged furnace is extremely dangerous. Attempts to use the furnace can result in fire or explosion. A qualified service agency
should be contacted to inspect the furnace and replace all gas controls, control system parts, electrical parts that have been wet or the
furnace if deemed necessary.
7. NEVER. . .Store flammable materials of any kind near your furnace.
Gasoline, solvents, and other volatile liquids should be stored only
in approved containers outside your home. These materials vaporize easily and are extremely dangerous.
8. NEVER. . .Store cleaning materials near your furnace. Materials
such as bleaches, detergents, powdered cleansers, etc., can cause
corrosion of the heat exchangers.
9. NEVER. . . Use the area around your furnace as a storage area for
items which could block the normal flow of air. This flow of air is
required for ventilation of the various furnace components.

356486-UUM-K-0613

356486-UUM-K-0613

INSTRUCTIONS FOR EXAMINING THE
FURNACE INSTALLATION
FIRE OR EXPLOSION HAZARD
This furnace is designed and approved for use with Natural Gas and
(LP) Propane Gas ONLY. DO NOT BURN ANY LIQUID FUEL OR
SOLID FUEL IN THIS FURNACE.
Burning any unapproved fuel will result in damage to the furnace heat
exchanger, which could result in Fire, Personal Injury, and/or Property
Damage.

Silicone
Tube
Induced
Draft Motor
Pressure
Switch
Limit
Switch
Electrical
Junction
Box
Flame
Sensor
Safety
Door
Switch

Vent Pipe
Flue Collar
Induced Draft
Assembly
Ignitor
Gas Valve
Rollout
Safety Switch
Manifold Pipe
Control Board
Capacitor
(Not used on all models)

Blower

Power Factor
Choke

Transformer

(Not used on
all models)

FIGURE 1: Component Location - 80% Single & Two Stage Models

Flue
Collar
Pressure
Switch

Silicone
Tube
Induced
Draft Motor
Pressure
Sensor
Limit Switch

Gas Valve
Electrical
Junction
Box
Silicone
Tube
Safety
Door
Switch

Flame Sensor
Limit Switch
Vent Pipe
Pressure Switch
Manifold Draft
Assembly
Condensate Pan
Control Board
Capacitor
(Not used on all models)

Transformer

Power Factor
Choke
(Not used on
all models)

Blower

FIGURE 2: Component Location - 95% Single & 96% Two Stage Models

Flue
Collar

Silicone
Tube

Induced Draft
Assembly
Gas Valve

Limit Switch

Gas Valve
Ignitor

Flame
Sensor

Manifold
Pipe

Safety
Door Switch

Control
Board
Capacitor

Transformer

Electrical
Junction Box

Rollout
Safety Switch

Flame
Sensor

Manifold
Pipe
Control
Board

Safety
Door Switch
Blower
Transformer

PSC MOTOR
FIGURE 3: Component Location - 80% Modulating PSC Models

2

Ignitor

Rollout Safety Switch

Pressure
Switch
Induced Draft
Assembly

Rollout
Safety Switch

Blower

Manifold
Pipe

Induced
Draft Motor
Pressure
Sensor

Ignitor

Electrical
Junction Box

It is the owner’s responsibility to ensure that an annual inspection of the
entire heating portion of the unit is made by a qualified service agency.
Examine the furnace as outlined below in steps “1 - 8” before each
heating season. Use Figures 1 - 6 for visual reference.

ECM MOTOR

Power Factor
Choke
(Not used on
all models)

FIGURE 4: Component Location - 80% Modulating ECM Models

Johnson Controls Unitary Products

356486-UUM-K-0613
Rollout
Safety Switch

Manifold
Pipe

Flame Sensor
Gas Valve

Ignitor
Limit Switch
(Behind gas valve)

Manifold
Pipe

Rollout
Safety Switch
Flame Sensor

Ignitor

Limit Switch
(Behind gas valve)

Gas Valve

Vent Pipe
Draft Inducer
Assembly

Electrical
Junction Box

Pressure
Switch

Silicone Tube

Condensate
Pan

Safety
Door Switch

Control
Board

Vent Pipe
Electrical
Junction Box

Draft Inducer
Assembly
Pressure
Switch

Silicone Tube

Condensate
Pan

Safety
Door Switch

Control
Board

Transformer

Transformer
Capacitor

Blower

PSC MOTOR
FIGURE 5: Component Location - 97% Modulating PSC Models
1. Examine the heat exchanger, vent pipe, combustion air passages,
vent connectors and chimney to be sure they are clear and free of
obstructions.
2. Examine the vent pipe making sure it is firmly in place, that it slopes
slightly upward and is physically sound without holes and all of the
connections are secure.
3. Examine the return-air duct connections to make sure they are
physically sound, sealed to the furnace casing, and the ducts terminate outside the space containing the furnace.
4. Examine the furnace casing making sure the physical support is
sound without sagging, cracks or gaps. Examine the furnace base
making sure it is physically sound without cracks, gaps or sagging
and has a good seal.
5. Examine the furnace casing for obvious signs of deterioration.
6. Examine the burner flames to make sure they are in good adjustment. Refer to the pictorial sketch shown in Figure 7 as a comparison to the actual flame.

Blue Cone Portion of Flame Should
Enter Heat Exchanger Tube

FIGURE 7: Burner Flame Drawing (Upflow Configuration Shown)
7. Examine and replace external air filters as needed to make sure
they are not blocked, and proper airflow is provided to the furnace.
8. Examine any installed accessories or system components such as
evaporator coils to insure proper operation, drainage of condensate, and that there is no water leakage or damage to the furnace
or any components.

Johnson Controls Unitary Products

Blower

ECM MOTOR

Power Factor
Choke (Not
used on all
models)

FIGURE 6: Component Location - 97% Modulating ECM Models

START-UP AND SHUTDOWN
INSTRUCTIONS
Read the Instructions Below Before Trying to Start the
Furnace!

If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury, and/or loss of life.

HOW YOUR GAS FURNACE WORKS
Your furnace is a very easy appliance to take for granted. Season after
season, it sits there in your home, keeping you warm and comfortable.
For this reason, you may never have given much thought to the way
your furnace operates. In order to get the safest and most efficient operation from your furnace, you should understand how your furnace does
its job.
When you set your thermostat to provide more heat in your home, you
are starting the heating cycle of the furnace. First, the inducer motor
starts to purge the heat exchanger of any remaining gases. Next, the
hot surface ignitor glows and after a warm-up period the gas valve
opens and ignition occurs. A short time later, the blower starts and distributes the warm air throughout the home. When the temperature setting on your thermostat is reached, the gas valve closes, the main
burners are turned off, and the blower continues to run until the remaining warm air in the system is distributed. When the blower stops, the
heating cycle has ended.
1. This appliance does not have a pilot. It is equipped with an ignition
device which automatically lights the burner. Do not try to light the
burner by hand.
2. BEFORE OPERATING; smell all around the appliance area for gas.
Be sure to smell next to the floor because some gas is heavier than
air and will settle on the floor.
3. Use only your hand to push the gas control switch to the ON position. Never use tools. If the switch will not operate by hand, don’t try
to repair it, call a qualified service technician. Force or attempted
repair may result in a fire or explosion.
4. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and
to replace any part of the control system and any gas control, which
has been under water.

3

356486-UUM-K-0613
OPERATING INSTRUCTIONS
1.
2.
3.
4.
5.
6.

7.
8.
9.
10.
11.

STOP! Read the safety information above for your protection.
Set the thermostat to the lowest setting in the heat mode.
Turn off all electric power to the appliance.
Remove furnace burner access panel/door.
Move gas control switch to the OFF position. Do not force. See Figures 9-11.
Wait five (5) minutes to clear out any gas. If you then smell gas,
STOP! Follow “B” in the safety information above. If you don’t smell
gas, go to next step.
Move gas control switch to the ON position. Do not force. See Figures 9-11.
Replace furnace burner access panel/door.
Turn on all electric power to the appliance.
Set thermostat to the desired setting. Burner will light, which may
take 30-60 seconds.
After three (3) trials for ignition, if the appliance will not operate follow the instructions, “TO TURN OFF THE APPLIANCE” and call
your service technician or gas supplier.

TO TURN OFF THE APPLIANCE
1. Set the thermostat to lowest setting in heating mode.
2. Turn off all electric power to the appliance if service is to be performed.
3. Remove furnace burner access panel/door.
4. Move gas control switch to the “OFF” position. See Figures 9-11.
5. Replace furnace burner access panel/door.

OUTLET
PRESSURE
PORT

HIGH STAGE REGULATOR
ADJUSTMENT
VENT
PORT

INLET

OUTLET

WRENCH
BOSS
INLET
PRESSURE
PORT

LOW STAGE REGULATOR
ADJUSTMENT

ON OFF
SWITCH

FIGURE 10: Two-Stage Gas Valve
Main
Regulator
Adjustment

On/Off
Switch

Inlet
Pressure
Tap

Outlet
Pressure
Tap

FIGURE 11: Modulating Gas Valve
Should overheating occur, or the gas valve fail to shut off, turn the
external manual gas valve in the gas supply line to the furnace to the
“off” position and let the furnace cool off before shutting off the electrical power supply.

Before proceeding, be sure the area is well ventilated. Turn the thermostat OFF. If the blower is running, wait until it stops automatically.
Turn OFF the gas and electrical power supplies to the furnace. Check
all metal parts and surfaces to be sure they have cooled to room temperature before you begin.

External Manual
Shutoff Valve
To Gas
Supply

To Gas
Supply

FURNACE MAINTENANCE - USER
INFORMATION

EXTERNAL AIR FILTERS

Drip Leg

Filters used with this furnace must be installed external to the furnace
casing. DO NOT attempt to install filters inside the furnace cabinet.

Grounded Joint Union
may be Installed
Inside or Outside Unit.

Some installations may have the air filter in a rack attached to the casing of the furnace or placed in the return air duct. If the filter location or
replacement process is not obvious, contact your installer or service
technician for assistance.

FIGURE 8: Gas Piping

Outlet
Pressure
Port
Inlet
Wrench
Boss
Inlet
Pressure
Port

Vent Port

FF
O

Outlet

N
Main Regulator
O
Adjustment
On/Off Switch
(Shown in ON position)

FIGURE 9: Single Stage Gas Valve

Every time the external air filters are changed the following items should
be visually inspected:
• Check combustion air and vent pipe for blockage or leakage.
• Check all components to be sure they are in good condition and
that there are no obvious signs of deterioration.
• Check the drain lines to make sure there are no cracks or leaks.
• Check for dirt or lint on any surfaces or on components. Do not try
to clean any of the surfaces or components. Cleaning of the furnace and its components must be done by a qualified service professional.
If during the inspection of your furnace, you find any of the following
conditions:
•
•
•
•

4

Excessive amounts of dust and lint on components.
Damaged or deteriorated components or surfaces.
Leaks or blockage in the vent pipe passages.
Water on any surface inside or outside of the furnace.

Johnson Controls Unitary Products

356486-UUM-K-0613
Do not operate the furnace, call a certified dealer or servicing contractor
to check or clean your furnace, or for more information if you have
questions about the operation of your furnace.
If all components appear to be in good operating condition, replace the
furnace access panels/doors. Turn ON the gas and electrical power
supplies to the furnace, and set thermostat to the desired temperature.

How to Clean your Filter
High-velocity filters may be cleaned with a vacuum cleaner or washed
with a garden hose. Be sure to shake off excess water and allow filter to
completely dry before re-installing the filter.
Replace throw away filter(s) with the same size new filter(s). Throw
away filter(s) may be replaced with cleanable filter(s) at this time.

BLOWER CARE
Even with good filters properly in place, blower wheels and motors will
become dust laden after months of operation. The entire blower assembly should be inspected annually. This service must be performed by a
qualified service agency.
NOTE: The spring-loaded safety cut-off switch, mounted at the blower
deck will automatically cut off the electrical power supply to the furnace
when the furnace blower access panel/door is removed. As a safety
precaution, all electrical power and the gas supply to the furnace should
be turned off before servicing.

Make sure you DO NOT move the clip on weight on the
indoor fan wheel when cleaning the wheel. This weight is
used to balance the wheel. Moving the weight will cause the
fan wheel to vibrate.

MOTOR LUBRICATION
The motors in these furnaces are permanently lubricated, and do not
require periodic oiling.

SERVICE INFORMATION
TROUBLESHOOTING PROBLEMS
If your furnace is not operating correctly, the following visual checks
should be made before contacting your local contractor, dealer, or service provider.
1. Check that electrical power to the furnace is turned on.
2. Check that the manual gas shut-off valve in the gas piping supply is
turned to the ON position. Refer to Figure 8.
3. Check that the ON/OFF switch on the gas valve is turned to the ON
position. Refer to Figures 9, 10 or 11.
4. Check that the furnace blower access panel/door is correctly positioned. The electrical power supply will be cut off if this door is
removed.

Johnson Controls Unitary Products

FURNACE CONTROL DIAGNOSTICS
The furnace has built-in, self-diagnostic capability. If a system problem
occurs, a blinking LED shows a fault code. The LED can flash red,
green or amber to indicate various conditions. It is located behind a
clear view port in the blower compartment door.
The control continuously monitors its own operation and the operation
of the system. If a failure occurs, the LED will indicate the failure code. If
the failure is internal to the control, the light will stay on continuously. In
this case, the entire control should be replaced, as the control is not
field repairable.
Flash sequence codes 1 through 10 are as follows: LED will turn ON for
1/4 second and OFF for 1/4 second. This pattern will be repeated the
number of times equal to the code. For example, six ON flashes equals
a number 6 fault code. All flash code sequences are broken by a 2 second OFF period.
SLOW GREEN FLASH: Normal operation.
DOUBLE AMBER FLASH: Normal heating operation - Modulating Furnace Models Only
SLOW AMBER FLASH: Normal operation with call for heat.
RAPID RED FLASHES: There is a problem with the operation of this
furnace. Contact your local dealer, contractor or service provider.

FURNACE MAINTENANCE - DEALER/CONTRACTOR
The furnace should be cleaned and adjusted by a certified dealer or
qualified service contractor once a year or before the start of every
heating season. The following items must be cleaned and serviced or
replaced if there are signs of deterioration.
1. The vent terminal.
2. The furnace vent and combustion air intake passageways. Should it
be necessary to service the vent/air intake system, the manufacturer recommends this service be conducted by a qualified service
agency. The operation of this appliance requires the reassembly
and resealing of the vent/air intake system.
3. The furnace burners, ignitor and flame sensor.
4. The condensate collection and disposal system. If any disassembly
of components containing flue or vent gases is required, a qualified
service agency must perform the service.
5. Heat exchanger assembly.
6. Induced draft motor assembly.

REPLACEMENT PARTS LIST
All components, assemblies, accessories, and replacement parts for
this furnace are available through qualified service agencies. It is not
recommended that the user purchase, install, or replace any components of this furnace. Contact your local contactor, dealer, or service
provider for additional information.

WIRING DIAGRAM
The unit wiring diagram may be found on the inside of one of the access
panels on the furnace. It is intended for reference only. If service is
required, contact your local contactor, dealer, or service provider.

5

356486-UUM-K-0613

NOTES

6

Johnson Controls Unitary Products

356486-UUM-K-0613

Limited Warranty
Residential Furnaces
WARRANTY TERMS: Johnson Controls Unitary Products (hereinafter “Company”) warrants this product to be free from defects in factory workmanship and material under normal use and service and will, at its option, repair or replace any parts, without charge, subject to the exclusions below,
that prove to have such defects according to the terms outlined in this warranty. Company reserves the right, at its sole discretion, to provide a
replacement unit in the place of repair parts, in which case the warranty period for the replacement unit is limited to the remainder of the original warranty period. Alternatively, Company may, at its option, extend a replacement allowance to be applied toward the purchase of a new unit marketed by
Company. The exact amount of the allowance will be determined at the discretion of Company, based upon current market conditions, but in no case
shall this allowance exceed thirty (30) percent of the original consumer purchase price of the unit excluding such items as ductwork, wiring, piping,
and installation costs. The warranty period for repair or replacement parts or unit provided hereunder shall not extend beyond the warranty period
stated below. Company shall have no responsibility hereunder for installation, shipping, handling, or other charges except as specifically provided
herein.
This warranty covers only the equipment described by the Product Model Number and Unit Serial Number on the equipment or listed on the Warranty Registration Card, and applies only to products installed in the United States, Canada, or Puerto Rico. Tampering, altering, defacing, or removing the product serial number will serve to void this warranty. This warranty extends only to the original consumer purchaser and is nontransferable.
For this warranty to apply, the product must be installed according to Company recommendations and specifications, and in accordance with all
local, state, and national codes; and the product or residence must not be removed from its place of original installation. This warranty does not apply
to any unit sold over the Internet, by telephone or other electronic means unless the dealer that buys or sells a unit over the Internet, by telephone or
other electronic means also installs the unit. In the absence of a recorded Warranty Registration Card, the warranty period will begin upon product
shipment from Company. If you are unaware of the date the warranty became effective, contact Company at (877) 874-7378 or visit www.upgproductregistration.com.
ADDITIONAL CONDITIONS FOR HEAT EXCHANGER WARRANTY: This warranty shall cover the heat exchanger (primary and/or secondary, if
applicable) only if:
1. The product has not been operated with an input rate in excess of the rating plate attached to the product.
2. The product has not been allowed to operate without the use of the proper automatic limit control on the maximum warm air temperature
and/or without adequate circulation.
3. The product is installed so that the combustion air is not contaminated by compounds of chlorine, fluorine, or other damaging chemicals
(or vapors).
4. The product is installed such that the heat exchangers are not exposed to return air temperatures below stated ratings.
FOR PRODUCT REGISTRATION: For your benefit and protection, register your product with Company promptly after installation. This will initiate
the warranty period and allow us to contact you, should it become necessary. You can register your product online at www.upgproductregistration.com or by returning the Warranty Registration Card on the back page of this packet.
Product Model Number: ____________________________________

Installation Date: __________________________________________

Unit Serial Number: _______________________________________

Installing Dealer: __________________________________________

FOR WARRANTY SERVICE OR REPAIR: Notify your Installing Dealer or a Participating Dealer, preferably in writing, as soon as possible after discovery of the problem. Be sure to include the Product Model Number, Unit Serial Number, Installation Date, and a description of the problem. You
may find the Installing Dealer's name on this page or on the equipment, and you can locate Participating Dealers online at www.yorkupg.com.
If a Dealer response is not received within a reasonable amount of time, notify Company at: Johnson Controls Unitary Products, Consumer Relations, 5005 York Drive, Norman, OK 73069 or by telephone at (877) 874-7378. All warranty service or repair will be performed during regular business hours, Monday through Friday 9:00 AM - 5:00 PM. Service requests sent to Company without prior Dealer contact will be referred back to a
Participating Dealer. Because this process takes time, it is in the best interest of the Consumer to contact a Participating Dealer directly.
WARRANTY PERIOD: The warranty period in years, depending on the part, is as shown in the chart below.
FURNACE TYPE
GG8S,GGLS
TM8X,TMLX,TM8T,TMLT,TM8V,TMLV,TG8S,TGLS, RGF1L*P, RGF1L*E
GG9S
TM9V,TM9T,TM9X,TG9S,
TP9C,TP8C,TPLC,TM9M,TM8M,TMLM,YP9C,YP8C,YPLC,YM9M,YM8M,YMLM,
CP9C,CP8C,CPLC,CM9M,CM8M,CMLM,LP9C,LP8C,LPLC,LM9M,LM8M,LMLM,
RGF19*P, RGF19*E

HEAT EXCHANGER
Residential
Non-Residential
Applications
Applications
20
10
20
10

PARTS
5

20 or Lifetime‡

10

5 or 10†
5

20 or Lifetime‡

10

5 or 10†

NOTES:
To qualify for the † Extended 10-year parts warranty and/or the ‡ Lifetime heat exchanger warranty, the unit must be registered online at www.upgproductregistration.com within 90 days of installation for replacement units or within 90 days of closing for new home construction. In some states, registration is not required, but
proof of installation is required.
Guardian Brand products have a 5-year parts warranty and are not eligible for the 10-year parts warranty.

MAINTENANCE: Company strongly recommends regular periodic preventive maintenance on this equipment. The person most familiar with the
equipment in your HVAC system is a Participating Dealer. The Participating Dealer can ensure that your maintenance program meets the “Company
Warranty” conditions, maximize the equipment efficiency, and service your unit within the mandated guidelines with regard to unlawful discharge of
refrigerants into the atmosphere.

Johnson Controls Unitary Products

7

EXCLUSIONS: This warranty does not cover any:
1. Shipping, labor, or material charges or damages resulting from transportation, installation, or servicing.
2. Damage or repairs required as a consequence of mishandling, faulty installation, misapplication, abuse, improper servicing, unauthorized alteration, or improper operation.
3. Damages or failure to start resulting from improper voltage conditions, blown fuses, open circuit breakers, or other inadequacy or interruption of
electrical service or fuel supply.
4. Fuses, either internal or external to the product.
5. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing, or handling of either defective parts or replacement parts.
6. Products removed from their original location for reinstallation purposes.
7. Damages resulting from accident, abuse, fire, flood, alteration, or acts of God.
8. Damages resulting from use of the product in a corrosive atmosphere.
9. Normal maintenance, or damages resulting from failure to perform normal maintenance, as outlined in the installation and servicing instructions
or owner's manual.
10. Cleaning or replacement of filters, nozzles, or orifices.
11. Damages resulting from operation with inadequate supply of air or water; Damages resulting from failure to properly and regularly clean air and/
or water side of condenser and evaporator.
12. Damages resulting from: (I) freezing of condenser water or condensate; (II) inadequate or interrupted water supply; (III) use of corrosive water;
(IV) fouling or restriction of the water circuit by foreign material or like causes.
13. Damages caused by improper parts, components or accessories not suitable for use in or with the unit. For a list of parts that are known to be
compatible please reference the equipment renewal parts list, contact a Participating Dealer for assistance, or call 1-877-874-7378.
14. Electricity or fuel costs, or increases in fuel or electric costs, for any reason including additional or unusual use of supplemental electric heat.
This warranty is in lieu of all other express warranties. All implied warranties, including the implied warranty of merchantability and fitness for a particular purpose are limited in duration to the actual warranty period applicable to the part. Some states do not allow the disclaimer of implied warranties,
so the above disclaimer may not apply to you. In addition, some states do not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to you. In no event, whether as a result of breach of warranty or contract, tort (including negligence), strict liability, or otherwise, shall Company be liable for special, incidental, or consequential damages or expenses, including but not limited to loss of use of the equipment
or associated equipment, lost revenues or profits, cost of substitute equipment, or cost of fuel or electricity.
The above limitations shall inure to the benefit of Company's suppliers and subcontractors. The above limitation on consequential damages shall not
apply to injuries to persons in the case of consumer goods. Company does not assume, or authorize any other person to assume for Company, any
other liability for the sale of this product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state.

Subject to change without notice. Published in U.S.A.
Copyright © 2013 by Johnson Controls, Inc. All rights reserved.

York International Corp.
5005 York Drive
Norman, OK 73069

356486-UUM-K-0613
Supersedes: 356486-UUM-J-1211



Navigation menu