DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.

TECHNICAL GUIDE
UP TO 98%
MODULATING (ECM MOTOR)
GAS-FIRED RESIDENTIAL
MULTI-POSITION GAS FURNACES
MODELS: YP9C*C
NATURAL GAS
60 - 120 MBH INPUT

These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and vent piping.

FEATURES
•

•
•
•

•
•
•
•
•
•
•
•
EFFICIENCY
RATING
CERTIFIED

•
•

When paired with a
York heat pump

Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at

•
•
•
•
•
•

www.ahridirectory.org
•

WARRANTY
Lifetime limited warranty on both heat exchangers to the original purchaser; a 20-year limited warranty from original installation date to
subsequent purchaser.
10-year warranty on the heat exchanger in commercial applications.
Standard 5-year limited Parts warranty.
Extended 10-year limited parts warranty when product is registered online within 90 days of purchase for replacement or closing for new home construction.

•
•

•
•

Modulating heating operation includes:
- Modulating gas valve, inducer and circulating blower
- Modulating operation from 100% to 35% input in 100
increments with nearly constant temperature rise.
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
ECM variable speed drive for cooling SEER enhancement,
improved comfort with optional airflow delay profiles, and
continuous fan options for IAQ performance.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement application.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
Airflow leakage less than 1% of nominal airflow for
ductblaster conditions.
Solid removable bottom panel allows easy conversion.
Hi-tech tubular aluminized steel primary heat exchanger with
stainless steel tube/aluminum fin secondary heat exchanger
for outstanding efficiency.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation, burner, and blower operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Insulated blower compartment for thermal and acoustic
performance.
1/4 turn knobs provided for easy independent door removal.
Internal condensate trap design (patent pending) provides
condensate management options, easy visual operation
check, and is self priming to prevent nuisance problems.
These models may be connected as part of a communicating
control system using a 4-wire connection bus.
The York YP9C modulating ECM furnace is part of a “Hybrid
Comfort System” when paired with a York Heat Pump.

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

538513- YTG-A-0809
LEFT SIDE

RIGHT SIDE

FRONT

Combustion Air Inlet
Condensate Drain
(Downflow)

Combustion Air Inlet

Gas Pipe
Entry

2” Vent
Connection
Outlet

Gas Pipe
Entry

Electrical
Entry

Condensate Drain
(Downflow)

Electrical
Entry

Condensate
Drain

33”

Thermostat
Wiring

2” Vent
Connection
Outlet
23”

Condensate
Drain
Thermostat
Wiring

Optional Return Air
Cutout (Either side)

14”
1”

28.5”
30.25”

A

1.5”

.56”
23.8”

2” Vent
Connection
Outlet

Combustion
Air Inlet

B

.56”

3”

.56”

B
C

24.25”

20”

RETURN END

SUPPLY END

Cabinet and Duct Dimensions
Models

Nominal CFM

Cabinet Size

YP9C060B12MP12C
YP9C080B12MP12C
YP9C080C16MP12C
YP9C100C16MP12C
YP9C100C20MP12C
YP9C120D20MP12C

1200
1200
1600
1600
2000
2000

B
B
C
C
C
D

Cabinet Dimensions (Inches)
A
17 1/2
17 1/2
21
21
21
24 1/2

B
16 3/8
16 3/8
19 7/8
19 7/8
19 7/8
23 3/8

C
13 1/4
14 3/4
16 1/2
18 1/4
18 1/4
21 3/4

Air Temp.
Rise Max Input

Air Temp.
Rise Min Input

7.0
7.5
10.0
10.0
12.0
12.0

°F
40-70
40-70
40-70
40-70
45-75
45-75

°F
20-50
20-50
20-50
20-50
25-55
25-55

Blower
Wheel Size

Max
Over-Current
Protect

Min. wire Size
(awg) @ 75 ft
one way

Approximate
Operating Weights

11 x 8
11 x 8
11 x 10
11 x 10
11 x 11
11 x 11

15
15
15
15
20
20

14
14
14
14
12
12

Ratings & Physical / Electrical Data
Models

Input
Max/Min

Output
Max/Min

AFUE

Nominal
Airflow

YP9C060B12MP12C
YP9C080B12MP12C
YP9C080C16MP12C
YP9C100C16MP12C
YP9C100C20MP12C
YP9C120D20MP12C

MBH
60/21
80/28
80/28
100/35
100/35
120/42

MBH
58/20
77/27
78/27
97/34
97/34
116/40

%
97.5
97.5
97.7
97.7
97.7
98.0

CFM
1200
1200
1600
1600
2000
2000

Models

Max. Outlet
Air Temp

YP9C060B12MP12C
YP9C080B12MP12C
YP9C080C16MP12C
YP9C100C16MP112C
YP9C100C20MP12C
YP9C120D20MP12C

°F
170
175
175
175
180
180

Blower
HP
1/2
1/2
3/4
3/4
1
1

Amps
4.8
4.8
7.5
7.5
14.5
14.5

Total
Unit
Amps

Lbs
113
119
134
140
143
152

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.

2

Johnson Controls Unitary Products

538513- YTG-A-0809

FILTER PERFORMANCE

Sidewall Vent Termination Kit -

The airflow capacity data published in the “Blower Performance” table represents blower performance WITHOUT filters.

S1-1HT0901 (3")
S1-1HT0902 (2")

All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace.

For use on sidewall, two-pipe installations only. Provide a more
attractive termination for locations where the terminal is visable
on the side of the home.

NOTE: Single side return above 1800 CFM is approved as long
as the filter velocity does not exceed filter manufacturer’s recommendation and a transition is used to allow use of a 20 x 25
filter.
Recommended Filter Sizes
CFM

Cabinet
Size

Side
(in)

Bottom
(in)

1200

B

16 x 25

16 x 25

Condensate Neutralizer Kit 1NK0301
Neutralizer cartridge has a 1/2" plastic tube fittings for installation in the drain line. Calcium carbonate refill media is also
available from the Source 1 Parts (p/n 026-30228-000).
Side Return Filter Racks -

1600

C

16 x 25

20 x 25

1SR0200 - All Models
1SR0402 - All Models
1SF0101 - All Models

2000

C

(2) 16 x 25

20 x 25

Bottom Return Filter Racks -

2000

D

(2) 16 x 25

22 x 25

1BR0517 or 1BR0617 - For 17-1/2” cabinets
1BR0521 or 1BR0621 - For 21” cabinets
1BR0524 or 1BR0624 - For 24-1/2” cabinets

NOTES:
1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters.
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one return with a transition to allow use of a 20x25 filter.

Combustible Floor Base Kit -

Unit Clearances to Combustibles
Upflow

Application

Downflow

Horizontal
0"

Top

1"

0"

Vent

0"

0"

0"

Rear

0"

0"

0"

Side

0"

0"

1"

0"

0"

Front

1

1BR05xx series are galvanized steel filter racks. 1BR06xx are
pre-painted steel filter racks to match the appearance of the furnace cabinet.

0"
2

Floor

Combustible

Combustible

Closet

Yes

Yes

Yes

Line Contact

No

No

Yes

Combustible

1. Line contact only permitted between lines formed by the intersection of the
rear panel and side panel (top in horizontal position) of the furnace jacket
and building joists, studs or framing.
2. For combustible floors only when used with special sub-base.
All furnaces approved for alcove and attic installation.

ACCESSORIES
Propane (LP) Conversion Kit 1NP0681 - All Models
This accessory conversion kit may be used to convert natural
gas (N) units for propane (LP) operation.
Do not use Conversion Kit S1-1NP0680 with these models, as
the control/gas valve combination have been updated, and that
kit S1-1NP0680 will not function correctly with these models.

For installation of these furnaces in downflow applications
directly onto combustible flooring material, These kits are
required to prevent potential overheating situations. These kits
are also required in any applications where the furnace in
installed in a downflow configuration without an evaporator coil,
where the combustible floor base kit provides access for combustible airflow.
1CB0517 - For 17-1/2” cabinets
1CB0521 - For 21” cabinets
1CB0524 - For 24-1/2” cabinets
EAC Transition Kits For installation of EAC accessories with these furnaces to provide easy transition of return airflow through the EAC to get the
proper sealing and reduced airflow leakage.
1TK1001 - For all models using side return
1TK1017 - For 17-1/2” cabinets using bottom return
1TK1021 - For 21” cabinets using bottom return
1TK1024 - For 24-1/2” cabinets using bottom return
High Altitude - No high altitude kits are required.
Thermostats - Compatible thermostat controls are available
through accessory sourcing. For optimum performance and
installation, refer to the UPGNET “Low Voltage Wiring Diagram”
document to select and apply controls.

Concentric Vent Termination S1-1CT0302 (2")
S1-1CT0303 (3")
For use through rooftop, sidewall. Allows combustion air to
enter and exhaust to exit through single common hole. Eliminates unslightly elbows for a cleaner installation.
Johnson Controls Unitary Products

3

Blower Performance CFM - Any Position
High / Low Speed Cooling CFM
060B12*C

080B12*C

Jumper Settings

Hi Cool

Lo Cool

Hi Cool

Lo Cool

COOL Jumper

ADJ Jumper

1305

850

1290

840

H

B

1100

715

1090

710

MH

B

1065

690

1015

660

H

A

1000

650

1000

650

MH

A

960

625

960

625

H

C

760

495

760

495

ML

B

900

585

900

585

MH

C

660

430

660

430

L

B

690

450

680

445

ML

A

600

400

600

400

L

A

620

400

620

400

ML

C

550

400

540

400

L

C

High / Low Speed Cooling CFM
080C16*C

100C16*C

Jumper Settings

Hi Cool

Lo Cool

Hi Cool

Lo Cool

COOL Jumper

ADJ Jumper

1670

1085

1655

1075

H

B

1295

840

1275

820

MH

B

1385

900

1345

875

H

A

1175

765

1160

755

MH

A

1245

810

1210

785

H

C

995

645

1000

650

ML

B

1055

685

1045

680

MH

C

935

605

955

620

L

B

905

590

910

590

ML

A

850

550

870

565

L

A

815

530

815

530

ML

C

765

500

785

510

L

C

High / Low Speed Cooling CFM
100C20*C

120D20*C

Jumper Settings

Hi Cool

Lo Cool

Hi Cool

Lo Cool

COOL Jumper

ADJ Jumper

2215

1440

2180

1415

H

B

1765

1145

1760

1140

MH

B

1820

1180

1800

1170

H

A

1605

1040

1595

1035

MH

A

1635

1060

1620

1050

H

C

1270

825

1255

815

ML

B

1445

940

1435

935

MH

C

1055

685

1050

680

L

B

1155

750

1160

755

ML

A

960

620

960

615

L

A

1040

675

1035

670

ML

C

860

560

840

545

L

C

All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0”
to 0.6” w.c. static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than
1.0” w.c. external static pressure is not recommended.
NOTE: At some settings, LOW COOL airflow may be lower that what is required to operate an airflow switch on certain models of electronic air cleaners. Consult the instructions for the electronic air cleaner for further details.

Subject to change without notice. Published in U.S.A.
Copyright © 2009 by Johnson Controls, Inc. All rights reserved.

Johnson Controls Unitary Products
5005 York Drive
Norman, OK 73069

538513- YTG-A-0809
Supersedes: 410821-YTG-C-0409



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : csardom
Create Date                     : 2009:11:02 07:37:57-06:00
Modify Date                     : 2009:11:02 09:29:45-06:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Title                           : 538510- UTG-A-0809.fm
Creator                         : csardom
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2009:11:02 09:29:45-06:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:013bb852-ceb2-4d17-9652-595591c8a820
Instance ID                     : uuid:6b148015-b41e-461c-ba72-3f1ff3fd180c
Page Layout                     : OneColumn
Page Mode                       : UseThumbs
Page Count                      : 4
EXIF Metadata provided by EXIF.tools

Navigation menu