HS-FC200+ Z-Wave Plus Fan Controller

OVERVIEW

HS-FC200+ is a Z-Wave controllable wired fan controller for use with 3-speed or 4-speed ceiling fans. See

WARNING RISK OF FIRE | RISK OF ELECTRICAL SHOCK | RISK OF BURNS
DO NOT USE THIS SWITCH TO CONTROL ANYTHING THAT MAY PRESENT A HAZARD WHEN CONTROLLED REMOTELY OR USED IN AN
UNATTENDED FASHION. DO NOT USE WITH MEDICAL AND LIFE SUPPORT INSTRUMENTS.

INSTALLATION
Tools required:
1

Be sure to set your exis�ng ceiling fan to the highest speed before you turn off the power to the circuit.

2

Shut off power to the circuit at the circuit breaker or fuse box.
al

3
box but leave the wires connected.
4

There may be up to five wires connected to the exis�ng fan controller. Make note of these wires and label, if necessary, to
ensure correct installa�on of HS-FC200+. You will need to match these wires with the corresponding screw terminals on
HS-FC200+. Note:LINE, NEUTRAL and LOAD wires are required for every installa�on
• LINE (Hot) - Black (connected to power)
• NEUTRAL - White (this wire is o�en �ed to other neutral wires and may require a jumper to connect with HS-FC200+)
• LOAD - Black (connected to load)
• GROUND — Green or Bare
• TRAVELER — Red/Other (only used in 3-way circuits)

5

Disconnect the wires from the exis�ng fan controller and a�ach those wires to HS-FC200+ using the screw terminal connectors
on the back with the following procedure:
1 Strip 16 mm (5/8”)
*.
3 There are two holes on the back of the fan controller near each screw terminal. Insert the stripped wire into one of these
holes and �ghten the screw terminal to secure the connec�on. Connec�ons should be snug.
*all wires should be 14 AWG or larger rated at 80°C or higher, �ghtening torque should be 12 lbf-in (14kgf-cm),
use copper wire only.
Carefully install the wired fan controller back into the electrical box and rea�ach the trim plate.

6

Neutral

Neutral
Ground

Ground

Ground
Load

Load
Traveler

Load

Traveler

Traveler

Load

Neutral
Line Hot
120VAC
HS-FC200+
60Hz
Single Pole circuit

COMPATIBILITY

Neutral

Neutral

HS-WA100+

Line Hot
120VAC
HS-FC200+
60Hz

3-way circuit

Your new HomeSeer fan controller is designed to work with 3 or 4 speed AC powered ceiling fans that do not have a light with the fan
or installa�ons where you have a separate wall switch for the fan and the light. In the event that you have a light with the fan in the
same circuit/switch, the light will dim or turn off whenever you set the fan at lower speed than the highest posi�on. HS-FC200+ is a
Z-Wave Plus cer�fied and is ready to be used with a variety of home automa�on controllers. The special features of HS-FC200+ are
supported using a number of different Z-Wave technologies. HomeSeer systems are designed to support these technologies and will
provide the most seamless operation of these features. However, other systems may also provide sa�sfactory results depending on the
level of support they provide for these same technologies. If you’re using a non-HomeSeer system, be sure to check our support page
(https://homeseer.com/support-home/) for further details.
Page 1

HomeSeer | 10 Commerce Park North, Suite 10 | Bedford, NH 03110 | HomeSeer.com | HS-FC200-en-v4
-

Z-WAVE INCLUSION/ EXCLUSION

Inclusion/Exclusion: Add or remove the device into your network by a Z-Wave cer�fied controller. HS-FC200+ supports the latest S2
security and SmartStart offered by Z-Wave cer�fied controllers. If your controller supports S2 or SmartStart, please refer to the user
guide of the controller for detailed instruc�ons on adding or removing devices to/from the network. You should be able to add
HS-FC200+ into your network using the unique QR code or the DSK 5 digit pin located on the product or packaging. In addi�on, the
device can be added or removed using the following 2-step procedure:
1 Put your Z-Wave controller into inclusion mode. Consult your controller manual if you’re unsure how to do this.
HomeSeer users: press “Add Device” on your Z-Tool+ mobile app
2 Tap the paddle of your new HomeSeer fan controller to begin the inclusion process. This will take a few moments to complete.
HomeSeer users: Be sure to name the fan controller and assign it to a loca�on using Z-Tool+ when inclusion is done
MANUAL RESET - To be used only in the event that the network primary controller is lost or otherwise inoperable.
(1) Turn the fan controller on by tapping the top paddle once. (2)
(3) Quickly tap the bo�om
paddle 3 �mes. (4) If the LED turns off and then on again, the fan controller is reset. If not, repeat manual reset.

ASSOCIATION OPERATION

Your new HomeSeer fan controller may be operated locally (manually) or remotely using a Zautoma�on system.
Local Control:
• Press (tap) the top paddle to power the fan.
• Press (tap) the bo�om paddle to cut power to the fan.
• Press & hold or press & tap the top or bo�om paddle to increase or decrease fan speed. The LED indicators will
light to represent fan speed level.
Remote Control:
• On / Off / Dim control is available remotely. Consult your controller manual for details.
HomeSeer users: This fan controller creates 3 devices; a root device, central scene device and control device. The
root device may be used to manage Z-Wave se�ngs. The central scene device may be used as a trigger for events.
The control device will send on / off / dim commands.

ADVANCED FEATURES

Your new HomeSeer fan controller includes advanced features that may be accessed with HomeSeer (and other) systems,
be sure to check our support page (h�ps://homeseer.com/support-home/) for detailed informa�on regarding features and
integra�ons with other smart hubs and controllers.

S2 Security / SmartStart: S2 security is an advanced encription technology. SmartStart is a pre-provisioning technology that
provides easier inclusion with compatible controllers*. The DSK can be found on the front metal yoke of the device.
*Check our support page (h�ps://homeseer.com/support-home/) for a list of compa�ble controllers.

SPECIFICATIONS

NOTE: The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifica�ons or changes to this equipment. Such modifica�ons or changes could
Power
Requirements
120VAC / 60 Hz
void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
Max Load
Fan Motor
2.5 Amps (300 Wa�s)
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protec�on against harmful interference in a residen�al installa�on. This equipment generates uses
Frequency
908.4 / 916 MHz
and can radiate radio frequency energy and, if not installed and used in accordance with the
Z-Wave
Range
132 �. (open air)
instruc�ons, may cause harmful interference to radio communica�ons. However, there is no
guarantee that interference will not occur in a par�cular installa�on. If this equipment does cause
UL
(US,
Canada),
FCC/IC,
Z-Wave
Plus
Cer�fica�ons
harmful interference to radio or television recep�on, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separa�on between the equipment and receiver.
HomeSeer warrants to the original purchaser that this product, for the
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
warranty period, will be free from material defects and workmanship. This connected.
warranty is subject to proper installa�on and opera�on of the product.
-Consult the dealer or an experienced radio/TV technician for help
HomeSeer’s sole obliga�on, under this warranty, is to repair, replace or
IC statements:
correct any defect that was present at the �me of delivery. This warranty
This device complies with Part 15 of the FCC Rules and with RSS of Industry Canada. Opera�on is
does not extend to consequen�al or incidental damage to other products
subject to the following two condi�ons:
that may be used with this product. Warranty claims must be submi�ed in (1) This device may not cause harmful interference, and
wri�ng directly to HomeSeer at HomeSeer.com. Warranty period: limited 1 (2) this device must accept any interference received, including interference that may cause
year from date of purchase.
undesired opera�on.

WARRANTY

FCC statements:

This device complies with part 15 of the FCC rules. Opera�on is subject
to the following two condi�ons: (1) this device may not cause harmful
interference, and (2) this device must accept any interference
received, including interference that may cause undesired opera�on.

Page 2

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploita�on est autorisée aux deux condi�ons suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'u�lisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
suscep�ble d'en comprome�re le fonc�onnement.
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est
conforme à la norme NMB-003 du Canada.

HomeSeer | 10 Commerce Park North, Suite 10 | Bedford, NH 03110 | HomeSeer.com | HS-FC200-en-v4



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c067 79.157747, 2015/03/30-23:40:42
Producer                        : Adobe PDF library 15.00
Creator Tool                    : Adobe Illustrator CC 2015 (Windows)
Create Date                     : 2018:06:04 13:38:39-07:00
Modify Date                     : 2018:06:04 13:38:39-07:00
Metadata Date                   : 2018:06:04 13:38:39-07:00
Thumbnail Width                 : 256
Thumbnail Height                : 248
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 25275 bytes, use -b option to extract)
Document ID                     : xmp.did:a1f26012-c2af-3b48-ad23-91859aa5498a
Instance ID                     : uuid:ed1887db-0a8a-44a5-a3cf-16ef398d26d0
Rendition Class                 : proof:pdf
Original Document ID            : uuid:63528CDF-63DE-4F57-B51D-1D9AFC8D43D0
Derived From Instance ID        : uuid:a5fc387b-5151-4072-87dc-9335523cfc83
Derived From Document ID        : xmp.did:d1a6064a-f7bb-0540-9071-6045254d319d
Derived From Original Document ID: uuid:63528CDF-63DE-4F57-B51D-1D9AFC8D43D0
Derived From Rendition Class    : proof:pdf
History Action                  : saved, saved
History Instance ID             : xmp.iid:09f7dc07-4cc4-3548-9c91-99e3347880f2, xmp.iid:a1f26012-c2af-3b48-ad23-91859aa5498a
History When                    : 2018:03:26 13:17:07-07:00, 2018:06:04 13:38:29-07:00
History Software Agent          : Adobe Illustrator CC 2015 (Windows), Adobe Illustrator CC 2015 (Windows)
History Changed                 : /, /
Format                          : application/pdf
Creator                         : Mark
Title                           : HS FC200 Manual Market Cert v1
N Pages                         : 1
Has Visible Transparency        : False
Has Visible Overprint           : False
Max Page Size W                 : 215.900000
Max Page Size H                 : 279.400000
Max Page Size Unit              : Millimeters
Font Name                       : Calibri-Bold, Calibri, MyriadPro-Regular
Font Family                     : Calibri, Calibri, Myriad Pro
Font Face                       : Bold, Regular, Regular
Font Type                       : Open Type, Open Type, Open Type
Font Version                    : Version 6.21, Version 6.21, Version 2.103;PS 2.000;hotconv 1.0.68;makeotf.lib2.5.35818
Font Composite                  : False, False, False
Font File Name                  : calibrib.ttf, calibri.ttf, MyriadPro-Regular.otf
Plate Names                     : Cyan, Magenta, Yellow, Black
Swatch Group Name               : Default Swatch Group
Swatch Group Type               : 0
Swatch Colorant Swatch Name     : PANTONE Cool Gray 10 C
Swatch Colorant Type            : SPOT
Swatch Colorant Tint            : 100.000000
Swatch Colorant Mode            : Lab
Swatch Colorant L               : 42.745098
Swatch Colorant A               : 0
Swatch Colorant B               : -3
Page Count                      : 2
Author                          : Mark
EXIF Metadata provided by EXIF.tools

Navigation menu