HS-FC200+ Z-Wave Plus Fan Controller OVERVIEW HS-FC200+ is a Z-Wave controllable wired fan controller for use with 3-speed or 4-speed ceiling fans. See WARNING RISK OF FIRE | RISK OF ELECTRICAL SHOCK | RISK OF BURNS DO NOT USE THIS SWITCH TO CONTROL ANYTHING THAT MAY PRESENT A HAZARD WHEN CONTROLLED REMOTELY OR USED IN AN UNATTENDED FASHION. DO NOT USE WITH MEDICAL AND LIFE SUPPORT INSTRUMENTS. INSTALLATION Tools required: 1 Be sure to set your exis�ng ceiling fan to the highest speed before you turn off the power to the circuit. 2 Shut off power to the circuit at the circuit breaker or fuse box. al 3 box but leave the wires connected. 4 There may be up to five wires connected to the exis�ng fan controller. Make note of these wires and label, if necessary, to ensure correct installa�on of HS-FC200+. You will need to match these wires with the corresponding screw terminals on HS-FC200+. Note:LINE, NEUTRAL and LOAD wires are required for every installa�on • LINE (Hot) - Black (connected to power) • NEUTRAL - White (this wire is o�en �ed to other neutral wires and may require a jumper to connect with HS-FC200+) • LOAD - Black (connected to load) • GROUND — Green or Bare • TRAVELER — Red/Other (only used in 3-way circuits) 5 Disconnect the wires from the exis�ng fan controller and a�ach those wires to HS-FC200+ using the screw terminal connectors on the back with the following procedure: 1 Strip 16 mm (5/8”) *. 3 There are two holes on the back of the fan controller near each screw terminal. Insert the stripped wire into one of these holes and �ghten the screw terminal to secure the connec�on. Connec�ons should be snug. *all wires should be 14 AWG or larger rated at 80°C or higher, �ghtening torque should be 12 lbf-in (14kgf-cm), use copper wire only. Carefully install the wired fan controller back into the electrical box and rea�ach the trim plate. 6 Neutral Neutral Ground Ground Ground Load Load Traveler Load Traveler Traveler Load Neutral Line Hot 120VAC HS-FC200+ 60Hz Single Pole circuit COMPATIBILITY Neutral Neutral HS-WA100+ Line Hot 120VAC HS-FC200+ 60Hz 3-way circuit Your new HomeSeer fan controller is designed to work with 3 or 4 speed AC powered ceiling fans that do not have a light with the fan or installa�ons where you have a separate wall switch for the fan and the light. In the event that you have a light with the fan in the same circuit/switch, the light will dim or turn off whenever you set the fan at lower speed than the highest posi�on. HS-FC200+ is a Z-Wave Plus cer�fied and is ready to be used with a variety of home automa�on controllers. The special features of HS-FC200+ are supported using a number of different Z-Wave technologies. HomeSeer systems are designed to support these technologies and will provide the most seamless operation of these features. However, other systems may also provide sa�sfactory results depending on the level of support they provide for these same technologies. If you’re using a non-HomeSeer system, be sure to check our support page (https://homeseer.com/support-home/) for further details. Page 1 HomeSeer | 10 Commerce Park North, Suite 10 | Bedford, NH 03110 | HomeSeer.com | HS-FC200-en-v4 - Z-WAVE INCLUSION/ EXCLUSION Inclusion/Exclusion: Add or remove the device into your network by a Z-Wave cer�fied controller. HS-FC200+ supports the latest S2 security and SmartStart offered by Z-Wave cer�fied controllers. If your controller supports S2 or SmartStart, please refer to the user guide of the controller for detailed instruc�ons on adding or removing devices to/from the network. You should be able to add HS-FC200+ into your network using the unique QR code or the DSK 5 digit pin located on the product or packaging. In addi�on, the device can be added or removed using the following 2-step procedure: 1 Put your Z-Wave controller into inclusion mode. Consult your controller manual if you’re unsure how to do this. HomeSeer users: press “Add Device” on your Z-Tool+ mobile app 2 Tap the paddle of your new HomeSeer fan controller to begin the inclusion process. This will take a few moments to complete. HomeSeer users: Be sure to name the fan controller and assign it to a loca�on using Z-Tool+ when inclusion is done MANUAL RESET - To be used only in the event that the network primary controller is lost or otherwise inoperable. (1) Turn the fan controller on by tapping the top paddle once. (2) (3) Quickly tap the bo�om paddle 3 �mes. (4) If the LED turns off and then on again, the fan controller is reset. If not, repeat manual reset. ASSOCIATION OPERATION Your new HomeSeer fan controller may be operated locally (manually) or remotely using a Zautoma�on system. Local Control: • Press (tap) the top paddle to power the fan. • Press (tap) the bo�om paddle to cut power to the fan. • Press & hold or press & tap the top or bo�om paddle to increase or decrease fan speed. The LED indicators will light to represent fan speed level. Remote Control: • On / Off / Dim control is available remotely. Consult your controller manual for details. HomeSeer users: This fan controller creates 3 devices; a root device, central scene device and control device. The root device may be used to manage Z-Wave se�ngs. The central scene device may be used as a trigger for events. The control device will send on / off / dim commands. ADVANCED FEATURES Your new HomeSeer fan controller includes advanced features that may be accessed with HomeSeer (and other) systems, be sure to check our support page (h�ps://homeseer.com/support-home/) for detailed informa�on regarding features and integra�ons with other smart hubs and controllers. S2 Security / SmartStart: S2 security is an advanced encription technology. SmartStart is a pre-provisioning technology that provides easier inclusion with compatible controllers*. The DSK can be found on the front metal yoke of the device. *Check our support page (h�ps://homeseer.com/support-home/) for a list of compa�ble controllers. SPECIFICATIONS NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifica�ons or changes to this equipment. Such modifica�ons or changes could Power Requirements 120VAC / 60 Hz void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital Max Load Fan Motor 2.5 Amps (300 Wa�s) device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protec�on against harmful interference in a residen�al installa�on. This equipment generates uses Frequency 908.4 / 916 MHz and can radiate radio frequency energy and, if not installed and used in accordance with the Z-Wave Range 132 �. (open air) instruc�ons, may cause harmful interference to radio communica�ons. However, there is no guarantee that interference will not occur in a par�cular installa�on. If this equipment does cause UL (US, Canada), FCC/IC, Z-Wave Plus Cer�fica�ons harmful interference to radio or television recep�on, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separa�on between the equipment and receiver. HomeSeer warrants to the original purchaser that this product, for the -Connect the equipment into an outlet on a circuit different from that to which the receiver is warranty period, will be free from material defects and workmanship. This connected. warranty is subject to proper installa�on and opera�on of the product. -Consult the dealer or an experienced radio/TV technician for help HomeSeer’s sole obliga�on, under this warranty, is to repair, replace or IC statements: correct any defect that was present at the �me of delivery. This warranty This device complies with Part 15 of the FCC Rules and with RSS of Industry Canada. Opera�on is does not extend to consequen�al or incidental damage to other products subject to the following two condi�ons: that may be used with this product. Warranty claims must be submi�ed in (1) This device may not cause harmful interference, and wri�ng directly to HomeSeer at HomeSeer.com. Warranty period: limited 1 (2) this device must accept any interference received, including interference that may cause year from date of purchase. undesired opera�on. WARRANTY FCC statements: This device complies with part 15 of the FCC rules. Opera�on is subject to the following two condi�ons: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired opera�on. Page 2 Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploita�on est autorisée aux deux condi�ons suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'u�lisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscep�ble d'en comprome�re le fonc�onnement. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. HomeSeer | 10 Commerce Park North, Suite 10 | Bedford, NH 03110 | HomeSeer.com | HS-FC200-en-v4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.6-c067 79.157747, 2015/03/30-23:40:42 Producer : Adobe PDF library 15.00 Creator Tool : Adobe Illustrator CC 2015 (Windows) Create Date : 2018:06:04 13:38:39-07:00 Modify Date : 2018:06:04 13:38:39-07:00 Metadata Date : 2018:06:04 13:38:39-07:00 Thumbnail Width : 256 Thumbnail Height : 248 Thumbnail Format : JPEG Thumbnail Image : (Binary data 25275 bytes, use -b option to extract) Document ID : xmp.did:a1f26012-c2af-3b48-ad23-91859aa5498a Instance ID : uuid:ed1887db-0a8a-44a5-a3cf-16ef398d26d0 Rendition Class : proof:pdf Original Document ID : uuid:63528CDF-63DE-4F57-B51D-1D9AFC8D43D0 Derived From Instance ID : uuid:a5fc387b-5151-4072-87dc-9335523cfc83 Derived From Document ID : xmp.did:d1a6064a-f7bb-0540-9071-6045254d319d Derived From Original Document ID: uuid:63528CDF-63DE-4F57-B51D-1D9AFC8D43D0 Derived From Rendition Class : proof:pdf History Action : saved, saved History Instance ID : xmp.iid:09f7dc07-4cc4-3548-9c91-99e3347880f2, xmp.iid:a1f26012-c2af-3b48-ad23-91859aa5498a History When : 2018:03:26 13:17:07-07:00, 2018:06:04 13:38:29-07:00 History Software Agent : Adobe Illustrator CC 2015 (Windows), Adobe Illustrator CC 2015 (Windows) History Changed : /, / Format : application/pdf Creator : Mark Title : HS FC200 Manual Market Cert v1 N Pages : 1 Has Visible Transparency : False Has Visible Overprint : False Max Page Size W : 215.900000 Max Page Size H : 279.400000 Max Page Size Unit : Millimeters Font Name : Calibri-Bold, Calibri, MyriadPro-Regular Font Family : Calibri, Calibri, Myriad Pro Font Face : Bold, Regular, Regular Font Type : Open Type, Open Type, Open Type Font Version : Version 6.21, Version 6.21, Version 2.103;PS 2.000;hotconv 1.0.68;makeotf.lib2.5.35818 Font Composite : False, False, False Font File Name : calibrib.ttf, calibri.ttf, MyriadPro-Regular.otf Plate Names : Cyan, Magenta, Yellow, Black Swatch Group Name : Default Swatch Group Swatch Group Type : 0 Swatch Colorant Swatch Name : PANTONE Cool Gray 10 C Swatch Colorant Type : SPOT Swatch Colorant Tint : 100.000000 Swatch Colorant Mode : Lab Swatch Colorant L : 42.745098 Swatch Colorant A : 0 Swatch Colorant B : -3 Page Count : 2 Author : MarkEXIF Metadata provided by EXIF.tools