Z Wave Zfm 80Us 8041_F820 8041 0000 User Manual
2017-05-10
User Manual: Z-Wave Zfm-80Us ZFM-80US 385 docs
Open the PDF directly: View PDF .
Page Count: 2
Single switch (connected with input AC power source for the
load)
External Switch
ZFM-80 provides an option to user that can add an
external switch to control the On/Off function. ZFM-80US
can be placed into the switch box with external wall
switch cover. User can configure the external switch type
through the configuration command
Configuration Command for External
Switch
Advanced function "Conditional trigger
for Fail Safe Installation"
ZFM-80US provides an advanced function "Conditional trigger
for Fail Safe Installation". It can turn on or turn off the relay if
ZFM-80US has not received any Z-Wave commands from a
specified Z-Wave Node ID and within a specified period. For
example: Z-Wave gateway can monitor a Z-Wave device status
and power on equipment if this Z-Wave device is out of service.
Figure 1
Single switch (connected with an external power source for the
load)
Figure 2
Warning
The resistive household appliance connected into the Z-Wave
controlled outlet on this module must not exceed 230Vac 10A or
120Vac 15A.
RELAY (LOAD)
NL
L
N
RELAY (LOAD)
NL
L
N
External switch
External
power source
Load
Load
L'
N'
Introduction:
Thank you for choosing ZFM-80US Z-Wave control product. Our
Z-Wave enabled product allows user to remotely control resistive
household appliance, and make home control easy at low
installation / maintenance cost. You may begin with a few Z-
Wave enabled devices or build up a complete home automation
system with our products.
The ZFM-80US Fixture Switch Module is a Z-Wave enabled
device and fully compatible with any Z-Wave enabled network. It
allows remote On/Off control of specified resistive household
appliance. Each fixture switch module is designed to act as a
repeater, which will re-transmit the RF signal to ensure that the
signal is received by its intended destination by routing the signal
around obstacle and radio dead spots.
Glossary
Key Features:
- High output power
- Remote ON/OFF control via the Z-Wave controller
- Manual ON/OFF control with the front panel push button
- Support External ON/OFF key connects to the module
- Advanced function
Conditional trigger for "Fail Safe Installation"
- Support Network Wide Inclusion (NWI) and Explore Frames
- Screw terminals for wires connection
- Flexible mounting structure - mount inside gang box or any
place
Wireless Control
ZFM-80US/DA065
Z-Wave Fixture Switch Module
USER MANUAL
Device /
Light /
Node
Z-Wave
Network
Inclusion
Exclusion
Network
Wide
Inclusion
(NWI)
Association
Devices, lights and nodes are all terms
to describe an individual Z-Wave device.
These are all interchangeable when
setting up your Z-Wave network.
A collection of Z-Wave devices is controlled
by primary and secondary controllers
operating on the same system.
A Z-Wave network has its own unique ID
code so that controllers not in the network
can not control the system.
Add a Z-Wave device to the network.
Delete a Z-Wave device from the network.
Network Wide Inclusion (NWI) enables
both end-user friendly, Plug and Play like
Z-Wave network installation as well as
professional installation scenario where
the inclusion process in terms of time will
be reduced significantly. NWI is a feature
supported by a new frame type named
Explorer which enables the Z-Wave
protocol to implement Adaptive Source
Routing.
Association is used to organize nodes in
different groups allowing the device to
identify the nodes by a group identifier.
The groups can also be copied to other
devices.
()
RELAY LOAD
NL
Product Overview:
A
B
C
D
E
F
Mount
Status LED
ON/OFF/PROG Push button
External switch (S/W)
Z-Wave controlled output (isolated relay, RL)
AC input (L = terminal for Live lead;
N = terminal for Neutral lead)
A
D
B
C
E
F
Installation:
DANGER! SHOCK HAZARD. Read and understand these
instructions before installing. This device is intended for
installation in accordance with the National Electric code and
local regulations in the United States, or the Canadian Electrical
Code and local regulations in Canada. It is recommended that a
qualified electrician perform this installation.
For indoor use only in a dry location. Retain instructions for future
use.
Step 1 WARNING: To reduce the risk of fire or electric shock,
install in a controlled environment relatively free of
contaminants. To avoid fire, shock, or death; turn off
power at circuit breaker or fuse and test that power is off
before wiring!
Step 2 Identifying your wiring application: refer to figure 1
and 2
NOTE: If the wiring in the wall box does not resemble
any of above configurations, c on s ul t a qu al i fi ed
electrician.
Step 3 Connecting wires: refer to figure 1 or 2 and connect
the wires with correct symbols.
Use at less 90 C copper wire only and the stripped
wire end's length must be 9mm. The tightening torque
must be 3.5lb-in. (Make sure all wires are firmly fixed at
all terminals)
CAUTION : Risk of Electric Shock More than one disconnect
switch may be required to de-energize the equipment before
servicing.
S/W
S/W
RL
RL
L
N
External Switch
Parameter
Number
Set External switch type
Definitions
1 (0x01)
Parameter
Value
Disable External switch
Definitions
0 (0x00)
1 (0x01)
2 (0x02)
3 (0x03)
4 (0x04)
Type A:
Tact switch (normal open)
Type B:
Tact switch (normal close)
Type C:
Rocker switch
(short = On; open = Off),
default
Type D:
Rocker switch
(short = Off, open = On)
Example:
Example:
Example:
Example:
External switch
Restoring Factory Defaults
All Configuration Parameters can be restored to their factory
default settings by using your primary controller to reset the
device. (Delete device from the network)
WIRELESS INFORMATION
Wireless range:
This device has an open-air line-of-sight transmission distance of
25m which complies with the Z-Wave standards. Performance
can vary depending on the amount of objects in between Z-Wave
devices such as walls and furniture. Every Z-Wave device set up
in your network will act as a signal repeater allowing devices to
talk to each other and find alternate routes in the case of a
reception dead spot.
Radio frequency limitations:
1. Each wall or object (i.e.: refrigerator, bookshelf, large TV, etc)
can reduce the maximum range of 65 feet by up to 25 to 30%.
2. Plasterboard and wooden walls block less of the radio signal
then concrete, brick or tile walls which will have more of an
effect on signal strength.
3. Wall mounted Z-Wave devices will also suffer a loss of range
if they are housed in metal junction boxes which could also
reduce the range by up to 25 to 30%.
MAINTENANCE
1. Do not expose your ZFM-80US to dust, strong sunlight,
humidity, high temperatures or mechanical shocks.
2. Do not use corrosive or abrasive cleansers on your ZFM-
80US.
3. Keep the unit dust free by wiping it with a soft, dry cloth.
4. Do not disassemble your ZFM-80US, it contains no user-
serviceable parts.
TECHNICAL SPECIFICATIONS
Note: Specifications subject to change without notice due to continuing
product improvement
Certifications
FCC Information
FCC ID : ZGIDA065
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
Warning:
Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user authority
to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of
the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for
help.
Model no.
RF frequency
Input voltage
RF operating
distance
Z-Wave
association group
Output relay
power rating
Dimension
Weight
Storage
Operation
Temperature
Environment
ZFM-80US / DA065
908.42MHz
120Vac or 230Vac
up to 25m (line of sight between the Wireless
Controller and the closest Z-Wave receiver module.)
Support 1 association group;
Each association group contains 5 nodes max.
230Vac 10A max. or 120Vac 15A max.
(Resistive load)
68(L) x 35(W) x 25(H)mm
50g metal mount excluded; 70g metal mount included
o
-25~60 C
o
-5~45 C
Indoor use only
Configuration Command for "Conditional
trigger for Fail Safe Installation"
LED Indication Status:
Basic Operation
The connected device can be turned ON in two ways:
1. Manual control with the push button on the ZFM-80US.
2. Z-Wave remote controller.
Manual ON/OFF function
Z-Wave Remote Control
Include or exclude the Fixture Switch Module from the existing Z-
Wave home control network with your primary controller.
- Refer to your primary controller instructions to process the
inclusion / exclusion setup procedure.
- When prompted by your primary controller, click once on the
PROG button or external switch.
- The primary controller should indicate that the action was
successful. If the controller indicates the action was
unsuccessful, please repeat the procedure.
- Once the Fixture Switch Module is part of the network, the
same basic procedure is used to add the Fixture Switch
Module to groups or scenes. Refer to the primary controller's
instructions for details.
Support Association Command Class
ZFM-80US support one association group, this association
group contains 5 nodes max.
It is used to report the relay on/off status to specify nodes with
ZFM-80US predefined association group once the relay state
has been changed.
All On/All Off functions
Depending upon your primary controller, the Fixture Switch
Module can be set to respond to ALL ON and ALL OFF
commands up to four different ways. Some controllers may not
be able to change the response from its default setting. Please
refer to your controller's instructions for information on whether
or not it supports the configuration function and if so, how to
change this settings.
The four possible responses are:
- It will respond to ALL ON and the ALL OFF commands
(default).
- It will not respond to ALL ON and ALL OFF commands.
- It will respond to the ALL OFF command but will not respond
to the ALL ON command.
- It will respond to the ALL ON command but will not respond to
the ALL OFF command.
Turn the resistive household appliance On/Off by pressing the
button at front or external switch.
(Press the external switch to turn the resistive household
appliance on if it is in off stage and vice versa)
Parameter
Number
Set timeout period
Configure Node ID
number for Z-Wave
command source
Set relay output status if
timeout period has been
reached
Definitions
2 (0x02)
3 (0x03)
4 (0x04)
Parameter value range
0 ~ 240 (minutes)
(default value is 0
[function disabled])
1 ~ 232 (Node ID number)
(default value is 0
[function disabled])
1 = turn on relay
0 = turn off relay
(default value is 0)
Operations
LED flashes slowly
within 2 seconds then
stay on if external
switch stay in active
stage.
LED light up.
LED flashes slowly
within 2 seconds then
stay on.
LED flashes 2 times
then stay on.
LED flashes 6 times
rapidly then stay on.
Device already exist
in network
ZFM-80US
power on
Press
PROG button /
Press
external switch
(Learning mode)
Receive
command /
Send command
or data
Error
Device does NOT exist
in network
LED flashes slowly within
2 seconds then stay on if
external switch stay in
active stage.
LED flashes slowly within
4 minutes then stay on if
external switch stay in
inactive stage.
LED flashes slowly within
2 seconds then stay on.
N/A
N/A
LED Indication Status
-
-
-
-
BW8330
TM
(Z-URC 550)
BW8380
(ZRC- 100)
IC information
IC : 9548A-DA065
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2)this device must accept any interference, including
interference that may cause undesired operation of the
device.
This device complies with RSS-310 of Industry Canada.
Operation is subject to the condition that this device does not
cause harmful interference.
WARNINGS
Do not dispose of electrical appliances as unsorted municipal
waste, use separate collection facilities. Contact your local
government for information regarding the collection systems
available.
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
DID NOT QUALIFY FOR INSTRUMENT OF MEDICAL AND
LIFE SUPPORT EQUIPMENT
Z-Wave Fixture Switch Module never got qualified certificate to
supply power for medical instrument or any life support
equipment.
There is no user serviceable parts in the
Fixture Switch Module.
Please contact a qualified electrician to install this product. Do
not modify the fixture switch module in any way.
WARRANTY
ONE-YEAR LIMITED WARRANTY: Remotec warrants this
product to be free from defects in materials and workmanship
under normal use and service for a period of one year from the
original date of purchase from the distributor or dealer.
REMOTEC shall not be liable for:
- Damages caused by defective devices for indirect, incidental,
special, consequential or punitive damages, including, inter
alia, loss of profits, savings, data, loss of benefits, claims by
third parties and any property damage or personal injuries
arising from or related to the use of the device.
- Service trips to provide instruction on product use.
- Shipping costs for replacement products.
This warranty is limited to the repair or replacement of this
product only, if the purchase date cannot be substantiated, the
warranty period will begin on the date of manufacture as
indicated on this product. All warranty claims must be made to
Remotec appointed distributors or dealers during the applicable
warranty period. This warranty gives you specific legal right and
you may also have other rights which vary in each country.
F820-8041-0000Printed in China