ZTE 1800-2SW Intelligent Integrated Multi-Services Router User Manual ZXR10 ZSR Intelligent Integrated Multi Service Router Hardware Description

ZTE Corporation Intelligent Integrated Multi-Services Router ZXR10 ZSR Intelligent Integrated Multi Service Router Hardware Description

ZXR10 ZSR Intelligent Integrated Multi-Service Router Hardware Description

ZXR10ZSRV2IntelligentIntegratedMulti-ServiceRouterHardwareDescriptionVersion:2.00.20ZTECORPORATIONNo.55,Hi-techRoadSouth,ShenZhen,P .R.ChinaPostcode:518057Tel:+86-755-26771900Fax:+86-755-26770801URL:http://support.zte.com.cnE-mail:support@zte.com.cn
LEGALINFORMATIONCopyright©2014ZTECORPORATION.Thecontentsofthisdocumentareprotectedbycopyrightlawsandinternationaltreaties.Anyreproductionordistributionofthisdocumentoranyportionofthisdocument,inanyformbyanymeans,withoutthepriorwrittenconsentofZTECORPORATIONisprohibited.Additionally,thecontentsofthisdocumentareprotectedbycontractualcondentialityobligations.Allcompany,brandandproductnamesaretradeorservicemarks,orregisteredtradeorservicemarks,ofZTECORPORATIONoroftheirrespectiveowners.Thisdocumentisprovided“asis”,andallexpress,implied,orstatutorywarranties,representationsorconditionsaredisclaimed,includingwithoutlimitationanyimpliedwarrantyofmerchantability,tnessforaparticularpurpose,titleornon-infringement.ZTECORPORATIONanditslicensorsshallnotbeliablefordamagesresultingfromtheuseoforrelianceontheinformationcontainedherein.ZTECORPORATIONoritslicensorsmayhavecurrentorpendingintellectualpropertyrightsorapplicationscoveringthesubjectmatterofthisdocument.ExceptasexpresslyprovidedinanywrittenlicensebetweenZTECORPORATIONanditslicensee,theuserofthisdocumentshallnotacquireanylicensetothesubjectmatterherein.ZTECORPORATIONreservestherighttoupgradeormaketechnicalchangetothisproductwithoutfurthernotice.UsersmayvisittheZTEtechnicalsupportwebsitehttp://support.zte.com.cntoinquireforrelatedinformation.TheultimaterighttointerpretthisproductresidesinZTECORPORATION.RevisionHistoryRevisionNo.RevisionDateRevisionReasonR1.02015-03-30FirsteditionSerialNumber:SJ-20150204153047-004PublishingDate:2015-03-30(R1.0)SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ContentsAboutThisManual.........................................................................................IChapter1HardwareOverview...................................................................1-1Chapter2ZXR103800-8Chassis..............................................................2-12.1Structure............................................................................................................2-12.1.1OverviewandStructure............................................................................2-12.1.2SlotLayout..............................................................................................2-22.1.3SystemParameters..................................................................................2-32.2PowerSupply.....................................................................................................2-42.2.1ACPowerSupplyModule.........................................................................2-42.2.2DCPowerSupplyModule.........................................................................2-52.3FANModule.......................................................................................................2-6Chapter3ZXR102800-4Chassis..............................................................3-13.1Structure............................................................................................................3-13.1.1OverviewandStructure............................................................................3-13.1.2SlotLayout..............................................................................................3-23.1.3SystemParameters..................................................................................3-33.2PowerSupply.....................................................................................................3-33.2.1ACPowerSupplyModule.........................................................................3-43.2.2DCPowerSupplyModule.........................................................................3-53.3Fan...................................................................................................................3-6Chapter4ZXR101800-2SChassis...........................................................4-14.1Structure............................................................................................................4-14.1.1OverviewandStructure............................................................................4-14.1.2SlotLayout..............................................................................................4-44.1.3SystemParameters..................................................................................4-54.2PowerSupply.....................................................................................................4-6Chapter5ZXR102800-3EChassis...........................................................5-15.1Structure............................................................................................................5-15.1.1OverviewandStructure............................................................................5-15.1.2SlotDeployment.......................................................................................5-35.1.3SystemParameters..................................................................................5-45.2PowerSupplies..................................................................................................5-55.2.1ACPowerModule....................................................................................5-5ISJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
5.2.2DCPowerModule....................................................................................5-6Chapter6ZXR101800-2EChassis...........................................................6-16.1Structure............................................................................................................6-16.1.1OverviewandStructure............................................................................6-16.1.2Slots........................................................................................................6-36.1.3SystemParameters..................................................................................6-46.2PowerSupplies..................................................................................................6-46.2.1ACPowerModule....................................................................................6-56.2.2DCPowerModule....................................................................................6-6Chapter7MPFU..........................................................................................7-17.1RAC-2838-MPFU-A............................................................................................7-17.2RAC-2838-MPFU-B/RAC-2838-MPFU-C.............................................................7-3Chapter8GeneralProcessingBoards.....................................................8-18.1RAC-DPIU-OSU-A1...........................................................................................8-18.2RAC-DPIU-OSU-A2...........................................................................................8-38.3RAC-DPIU-FW-A...............................................................................................8-4Chapter9LineInterfaceBoards...............................................................9-19.1RAC-SPIU-02CE1-75.........................................................................................9-29.2RAC-SPIU-02UE1-75.........................................................................................9-39.3RAC-SPIU-02CE1-120.......................................................................................9-59.4RAC-SPIU-02UE1-120.......................................................................................9-69.5RAC-SPIU-02HS................................................................................................9-89.6RAC-SPIU-04GE................................................................................................9-99.7RAC-PIU-LTE...................................................................................................9-119.8RAC-PIU-01DSLB............................................................................................9-139.9RAC-PIU-04SHDSL.........................................................................................9-159.10RAC-PIU-04HS.............................................................................................9-169.11RAC-PIU-04CE1-75........................................................................................9-189.12RAC-PIU-04CE1-120......................................................................................9-199.13RAC-PIU-04UE1-75.......................................................................................9-219.14RAC-PIU-04UE1-120......................................................................................9-229.15RAC-PIU-16CE1............................................................................................9-239.16RAC-PIU-16CE1-CES....................................................................................9-259.17RAC-PIU-01P12-SFP.....................................................................................9-269.18RAC-PIU-02P3-SFP.......................................................................................9-289.19RAC-PIU-04P3-SFP.......................................................................................9-299.20RAC-PIU-02CP3-SFP.....................................................................................9-31IISJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
9.21RAC-PIU-04CP3-SFP.....................................................................................9-329.22RAC-PIU-04GE-SFP......................................................................................9-349.23RAC-PIU-08GE-SFP......................................................................................9-359.24RAC-PIU-05GE-4E1SFP................................................................................9-369.25RAC-PIU-09GE-8E1SFP................................................................................9-399.26RAC-PIU-08FE1GE-1SFP..............................................................................9-419.27RAC-DPIU-16GE-12SFP4E............................................................................9-439.28RAC-DPIU-01XGE-SFP+................................................................................9-45Chapter10Cables....................................................................................10-110.1PowerCablesandGroundingCables..............................................................10-110.1.1DCPowerCables.................................................................................10-110.1.2ACPowerCables.................................................................................10-310.1.3GroundingCables................................................................................10-410.2SignalCables.................................................................................................10-410.2.1AUXCables.........................................................................................10-410.2.2ConsoleCables....................................................................................10-510.2.3EthernetCables...................................................................................10-610.2.4OpticalFibers.......................................................................................10-710.2.5SHDSLCables.....................................................................................10-910.2.6Synchronous/AsynchronousSerialCable..............................................10-1010.2.7E1TrunkCable...................................................................................10-13AppendixABoardQuickTable(WeightandPowerConsumption)......A-1AppendixBOpticalModulesQuickTable...............................................B-1Figures.............................................................................................................ITables.............................................................................................................VGlossary......................................................................................................XIIIIIISJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Thispageintentionallyleftblank.IVSJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
AboutThisManualPurposeThismanualdescribesthehardwarestructure,components,systemcongurations,performance,physicalparametersandsupportedboardsandcablesoftheZXR10ZSRV2seriesrouters.IntendedAudienceThismanualisintendedfor:lNetworkplanningengineerslEquipmentinstallationengineerslInstallationsupervisionengineersWhatIsinThisManualThismanualcontainsthefollowingchaptersandappendixes.Chapter1,HardwareOverviewDescribesthehardwareoverviewoftheZXR10ZSRV2seriessrouters.Chapter2,ZXR103800-8ChassisDescribesthestructure,components,slots,systempa-rameters,powersupplies,andtheheatdissipationsys-temoftheZXR103800-8chassis.Chapter3,ZXR102800-4ChassisDescribesthestructure,components,slotlayout,systemparameters,powersupplies,andtheheatdissipationsys-temoftheZXR102800-4chassis.Chapter4,ZXR101800-2SChassisDescribesthestructure,components,slotlayout,systemparameters,powersupplies,andtheheatdissipationsys-temoftheZXR101800-2Schassis.Chapter5,ZXR102800-3EChassisDescribesthestructure,slotdeployment,systempa-rameters,powermodules,andfanmodulesofaZXR102800-3Echassis.Chapter6,ZXR101800-2EChassisDescribesthestructure,slotdeployment,systempa-rameters,powermodules,andfanmodulesofaZXR101800-2Echassis.Chapter7,MPFUDescribestheMPFUsupportedbyallZXR10ZSRV2seriesrouters.Chapter8,GeneralProcessingBoardsDescribesgeneralprocessingboardsthattheZXR10ZSRV2seriesrouterssupport.ISJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9,LineInterfaceBoardsDescribesthelineinterfaceboardssupportedbyallZXR10ZSRV2seriesrouters.Chapter10,CablesDescribesthepowercables,protectivegroundingcables,andsignalcablesoftheZXR10ZSRV2seriesrouters.AppendixA,BoardQuickT able(WeightandPowerConsumption)DescribestheweightandpowerconsumptionoftheboardssupportedbytheZXR10ZSRV2seriesrouters.AppendixB,OpticalModulesQuickTableDescribestheinformationoftheopticalmodulessup-portedbytheZXR10ZSRV2seriesrouters.ConventionsThismanualusesthefollowingconventions.ItalicsVariablesincommands.Itmayalsorefertootherrelatedmanualsanddocuments.BoldMenus,menuoptions,functionnames,inputelds,optionbuttonnames,checkboxes,drop-downlists,dialogboxnames,windownames,parameters,andcommands.ConstantwidthTextthatyoutype,programcodes,lenames,directorynames,andfunctionnames.[]Optionalparameters.{}Mandatoryparameters.|Separatesindividualparametersinaseriesofparameters.Warning:indicatesapotentiallyhazardoussituation.Failuretocomplycanresultinseriousinjury,equipmentdamage,orinterruptionofmajorservices.Caution:indicatesapotentiallyhazardoussituation.Failuretocomplycanresultinmoderateinjury,equipmentdamage,orinterruptionofminorservices.Note:providesadditionalinformationaboutacertaintopic.IISJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter1HardwareOverviewForthemajorhardwarecomponentsandmodelsoftheZXR10ZSRV2,refertoT able1-1.Thecomponentsvarywiththenetworkscaleandcapacity.Determinethecongurationaccordingtoyouractualrequirements.Table1-1ComponentModelsComponentModelDescriptionCabinet-Usedasrequired.TheZXR101800-2Sisadesktopproduct,theZXR101800-2EandZXR102800-3Ecanbeinstalledonadesktoporinacabinet,whiletheZXR102800-4andZXR103800-8canbeinstalledinanIEC297standardcabinetorETSIstandardcabinet.ShelfZXR103800-8ChassisZXR102800-4ChassisZXR101800-2SChassisContainschassisstructure,powersupplymodule,fananddustscreenmoduleandLCDmodule.MPFURefertoChapter7MPFU.ContainsMPFU.GeneralprocessingboardsRefertoChapter8GeneralProcessingBoards.GeneralprocessingboardsthattheZXR10ZSRV2seriesrouterssupport.LineInterfaceBoardsRefertoChapter9LineInterfaceBoards.Containslineinterfaceboards.CableRefertoChapter10Cables.Containspowercables,groundingcablesandsignalcables.1-1SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionThispageintentionallyleftblank.1-2SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter2ZXR103800-8ChassisTheZXR10ZSRV2seriesroutersarehighlyexiblebyusingthemodularstructure,andtheboardsandcomponentsarehotswappable.Theentirerouterconsistsofthechassis,backplane,MPFU,lineinterfaceboards,powersupplymodules,andfanmodules.TheZXR103800-8chassisusestheplatemetalstructure.Theboards,powersupplymodules,andfanmodulesareinstalledonthefrontpanel,andthefrontleading-outmode(opticalberinterfaces)isused.ThewidthoftheZXR103800-8chassiscomplieswiththe19-inchstandardandcanbeinstalledinIEC297orETSIstandardcabinets.TableofContentsStructure....................................................................................................................2-1PowerSupply.............................................................................................................2-4FANModule...............................................................................................................2-62.1Structure2.1.1OverviewandStructureTheheightoftheZXR103800-8chassisis3U(1U=1.75in.=44.45mm),andthedimensions(width×height×depth)are17.41in.×5.20in.×7.88in.(442mm×132mm×200mm).ForthemaincomponentsoftheZXR103800-8chassis,seeFigure2-1.Figure2-1MainComponentsontheFrontSideoftheZXR103800-8ChassisForthefrontviewoftheZXR103800-8chassis,seeFigure2-2.2-1SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionFigure2-2FrontViewoftheZXR103800-8Chassis1.Powersupplymodule2.SPIUlineinterfaceboardslots3.PIU/DPIUlineinterfaceboardslots4.Fanmodule5.MPFUslotsForadescriptionofthemaincomponentsoftheZXR103800-8chassis,refertoT able2-1.Table2-1DescriptionoftheMainComponentsoftheZXR103800-8ChassisComponentNameDescriptionBoardareaTheZXR103800-8providesoneslotforthemaincontrolforwardingboardandatmosteightslotsforlineinterfaces.PowersupplymoduleTheZXR103800-8providestwoslotsforpowermodules.Y oucancongureoneortwopowermodules.FanmoduleTheZXR103800-8providesoneverticallyinstalledfanmodule.2.1.2SlotLayoutForafrontviewoftheZXR103800-8chassis,seeFigure2-3.Figure2-3FrontViewoftheZXR103800-8ChassisTheZXR103800-8chassisprovidesnineserviceslotsandboardsarehorizontallyinstalledinthechassis.2-2SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter2ZXR103800-8ChassislTheMPFUisinstalledinslot8.lPIUs/DPIUsandSPIUsareinstalledinslots0to7.TheSPIUslotsareapplicabletoSPIUboards.ThePIUslotsareapplicabletoPIUboards.TheDPIUboardusestwoslots,includingonePIUslotanditsneighboringPIU/DPIUslot.2.1.3SystemParametersForthesystemparametersoftheZXR103800-8,refertoTable2-2.Table2-2SystemParametersoftheZXR103800-8ParameterSpecicationDimensions(width×height×depth)17.41in.×5.20in.×7.88in.(442mm×132mm×200mm)Weight(fullconguration)<25.4lb.(11.5kg)PhysicalparameterMaximumpowerconsumption<240WMemory2GB StoragecapacityFLASH4GBTotalnumberofslots9 SlotNumberofPIUslots8Redundancymode1+1redundancy,supportingACandDCmixedpowersupplyMaximumoutputpower250WRatedinputvoltage-60VDCto-48VDCDCpower(single)Inputvoltagerange-72VDCto-38VDCRedundancymode1+1redundancy,supportingACandDCmixedpowersupplyRatedinputvoltage100VACto240VACInputfrequencyrange50Hzto60HzACpower(single)Ratedoutputpowerpermodule250WHeatdissipationsystemNumberoffanmodules1GroundingresistanceResistanceofjointgrounding<5Ω2-3SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescription2.2PowerSupplyTheZXR10ZSRV2seriesrouterssupport100Vto240V,50Hzto60HzACpowersupplyand-72Vto-38VDCpowersupply.TheZXR103800-8supportsACandDCmixedpowersuppliesoperatingin1+1redundancymode,andthepowersupplymodulesarehotswappable.Apowersupplymoduleprovidesthefollowingfunctions:lInput/outputover/undervoltagealarmandprotection.lOutputovercurrentalarmandprotection.lTemperaturealarmandoverheatingprotection.Caution!Pleasedisconnectallpowersupplybeforeservicing.2.2.1ACPowerSupplyModulePanelForthefrontviewoftheACpowersupplymoduleoftheZXR103800-8,seeFigure2-4.Figure2-4PaneloftheACPowerSupplyModuleIndicatorsForadescriptionoftheZXR103800-8ACpowersupplyindicators,refertoT able2-3.Table2-3IndicatorDescriptionsfortheZXR103800-8ACPowerSupplyModuleIndicatorNumberColorDescriptionRUN1GreenIndicatesthatthepowersupplymoduleoperatesproperly.ALM1RedIndicatesthatthepowersupplymodulehasanalarm.2-4SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter2ZXR103800-8ChassisButtonsThereisonepowerbuttonontheZXR103800-8ACpowersupplymodule.Foradescriptionofthebutton,refertoT able2-4.Table2-4PowerButtonDescriptionfortheZXR103800-8ACPowerSupplyModuleButtonDescriptionON(—)Powersonthepowersupplymodule.OFF(O)Powersoffthepowersupplymodule.TechnicalParametersForthetechnicalparametersoftheACpowerrectieroftheZXR103800-8,refertoTable2-5.Table2-5TechnicalParametersoftheACPowerRectieroftheZXR103800-8ParameterSpecicationDimensions(height×width×depth)3.15in.×1.57in.×6.89in.(80mm×40mm×175mm)Weight0.68kgInputvoltagerange100VACto240VACACinputfrequency50Hzto60HzRatedoutputpower250W2.2.2DCPowerSupplyModulePanelForthefrontviewoftheDCpowersupplymoduleoftheZXR103800-8,seeFigure2-5.Figure2-5PaneloftheDCPowerSupplyModuleIndicatorsForadescriptionoftheZXR103800-8DCpowersupplyindicators,refertoTable2-6.2-5SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionTable2-6IndicatorDescriptionsfortheZXR103800-8DCPowerSupplyModuleIndicatorNumberColorDescriptionRUN1GreenIndicatesthatthepowersupplymoduleoperatesproperly.ALM1RedIndicatesthatthepowersupplymodulehasanalarm.ButtonsThereisonepowerbuttonontheZXR103800-8DCpowersupplymodule.Foradescriptionofthebutton,refertoT able2-7.Table2-7PowerButtonDescriptionfortheZXR103800-8DCPowerSupplyModuleButtonDescriptionON(—)Powersonthepowersupplymodule.OFF(O)Powersoffthepowersupplymodule.TechnicalParametersForthetechnicalparametersoftheDCpowersupplymoduleoftheZXR103800-8,refertoTable2-8.Table2-8TechnicalParametersoftheDCPowerSupplyModuleoftheZXR103800-8ParameterSpecicationDimensions(height×width×depth)3.15in.×1.57in.×6.89in.(80mm×40mm×175mm)Weight1.45lb.(0.52kg)Inputvoltagerange-72VDCto-48VDCMaximumoutputpower250WRatedinputcurrent8.5A2.3FANModuleThereisaverticalfanmoduleintheZXR103800-8chassis,whichconsistsoffourfans.Thecoolairentersthechassisfromitslateralside,owstotheboardsandpowersupplymodules,andthenisblownoutfromtheotherside.Thefanmodulecanautomaticallyadjustthefanspeedaccordingtotheequipmentoperationandsupportsthestatusmonitoringandalarmfunctions.ForthetechnicalspecicationsoftheZXR103800-8fanmodule,refertoTable2-9.2-6SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter2ZXR103800-8ChassisTable2-9ZXR103800-8FanSpecicationsParameterSpecicationSize(W×H×D)40.8mm×125.7mm×186mmWeight0.62kgPowerconsumption45WMaximumwindpressure23mmH2OMaximumwind287CFMMaximumnoise60dBAOperationvoltage12V2-7SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionThispageintentionallyleftblank.2-8SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter3ZXR102800-4ChassisTheZXR10ZSRV2seriesroutersarehighlyexiblebyusingthemodularstructure,andtheboardsandcomponentsarehotswappable.Theentirerouterconsistsofthechassis,backplane,MPFU,lineinterfaceboards,powersupplymodules,andfanmodules.TheZXR102800-4chassisusestheplatemetalstructure.Theboards,powersupplymodules,andfanmodulesareinstalledonthefrontpanel,andthefrontleading-outmode(opticalberinterfaces)isused.ThewidthoftheZXR102800-4chassiscomplieswiththe19-inchstandardandcanbeinstalledinIEC297orETSIstandardcabinets.TableofContentsStructure....................................................................................................................3-1PowerSupply.............................................................................................................3-3Fan............................................................................................................................3-63.1Structure3.1.1OverviewandStructureTheheightoftheZXR102800-4chassisis2U(1U=1.75in.=44.45mm),andthedimensions(width×height×depth)are17.41in.×3.46in.×7.88in.(442mm×88mm×200mm).ForthemaincomponentsoftheZXR102800-4chassis,seeFigure3-1.Figure3-1MainComponentsontheFrontSideoftheZXR102800-4ChassisForthefrontviewoftheZXR102800-4chassis,seeFigure3-2.3-1SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionFigure3-2FrontViewoftheZXR102800-4Chassis1.Powersupplymodule2.SPIUlineinterfaceboardslots3.PIU/DPIUlineinterfaceboardslots4.Fanmodule5.MPFUslotsForadescriptionofthemaincomponentsoftheZXR102800-4chassis,refertoT able3-1.Table3-1DescriptionoftheMainComponentsoftheZXR102800-4ChassisComponentNameDescriptionBoardareaTheZXR102800-4providesoneslotforthemaincontrolforwardingboardandatmostfourslotsforlineinterfaces.PowersupplymoduleTheZXR102800-4providestwoslotsforpowermodules.Youcancongureoneortwopowermodules.FanmoduleTheZXR102800-4providesoneverticallyinstalledfanmodule.3.1.2SlotLayoutForafrontviewoftheZXR102800-4chassis,seeFigure3-3.Figure3-3FrontViewoftheZXR102800-4ChassisTheZXR102800-4chassisprovidesveserviceslotsandboardsarehorizontallyinstalledinthechassis.lTheMPFUisinstalledinslot4.lPIUs/DPIUsandSPIUsareinstalledinslots0to3.TheSPIUslotsareapplicabletoSPIUboards.ThePIUslotsareapplicabletoPIUboards.TheDPIUboardusestwoslots,includingonePIUslotanditsneighboringPIU/DPIUslot.3-2SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter3ZXR102800-4Chassis3.1.3SystemParametersForthesystemparametersoftheZXR102800-4,refertoTable3-2.Table3-2SystemParametersoftheZXR102800-4ParameterSpecicationDimensions(width×height×depth)17.41in.×3.46in.×7.88in.(442mm×88mm×200mm)Weight(fullconguration)<19.0lb.(8.6kg)PhysicalparameterMaximumpowerconsumption<160WMemory2GB StoragecapacityFLASH4GBTotalnumberofslots5 SlotNumberofPIUslots4Redundancymode1+1redundancy,supportingACandDCmixedpowersupplyMaximumoutputpower250WRatedinputvoltage-60VDCto-48VDCDCpower(single)Inputvoltagerange-72VDCto-38VDCRedundancymode1+1redundancy,supportingACandDCmixedpowersupplyRatedinputvoltage100VACto240VACInputfrequencyrange50Hzto60HzACpower(single)Ratedoutputpowerpermodule250WHeatdissipationsystemNumberoffanmodules1GroundingresistanceResistanceofjointgrounding<5Ω3.2PowerSupplyTheZXR10ZSRV2seriesrouterssupport100Vto240V,50Hzto60HzACpowersupplyand-72Vto-38VDCpowersupply.TheZXR102800-4supportsACandDCmixedpowersuppliesoperatingin1+1redundancymode,andthepowersupplymodulesarehotswappable.3-3SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionApowersupplymoduleprovidesthefollowingfunctions:lInput/outputover/undervoltagealarmandprotection.lOutputovercurrentalarmandprotection.lTemperaturealarmandoverheatingprotection.Caution!Pleasedisconnectallpowersupplybeforeservicing.3.2.1ACPowerSupplyModulePanelForthefrontviewoftheACpowersupplymoduleoftheZXR102800-4,seeFigure3-4.Figure3-4PaneloftheACPowerSupplyModuleIndicatorsForadescriptionoftheZXR102800-4ACpowersupplyindicators,refertoT able3-3.Table3-3IndicatorDescriptionsfortheZXR102800-4ACPowerSupplyModuleIndicatorNumberColorDescriptionRUN1GreenIndicatesthatthepowersupplymoduleoperatesproperly.ALM1RedIndicatesthatthepowersupplymodulehasanalarm.ButtonsThereisonepowerbuttonontheZXR102800-4ACpowersupplymodule.Foradescriptionofthebutton,refertoT able3-4.Table3-4PowerButtonDescriptionfortheZXR102800-4ACPowerSupplyModuleButtonDescriptionON(—)Powersonthepowersupplymodule.3-4SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter3ZXR102800-4ChassisButtonDescriptionOFF(O)Powersoffthepowersupplymodule.TechnicalParametersForthetechnicalparametersoftheACpowerrectieroftheZXR102800-4,refertoTable3-5.Table3-5TechnicalParametersoftheACPowerRectieroftheZXR102800-4ParameterSpecicationDimensions(height×width×depth)3.15in.×1.57in.×6.89in.(80mm×40mm×175mm)Weight0.68kgInputvoltagerange100VACto240VACACinputfrequency50Hzto60HzRatedoutputpower250W3.2.2DCPowerSupplyModulePanelForthefrontviewoftheDCpowersupplymoduleoftheZXR102800-4,seeFigure3-5.Figure3-5PaneloftheDCPowerSupplyModuleIndicatorsForadescriptionoftheZXR102800-4DCpowersupplyindicators,refertoTable3-6.Table3-6IndicatorDescriptionsfortheZXR102800-4DCPowerSupplyModuleIndicatorNumberColorDescriptionRUN1GreenIndicatesthatthepowersupplymoduleoperatesproperly.ALM1RedIndicatesthatthepowersupplymodulehasanalarm.3-5SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionButtonsThereisonepowerbuttonontheZXR102800-4DCpowersupplymodule.Foradescriptionofthebutton,refertoT able3-7.Table3-7PowerButtonDescriptionfortheZXR102800-4DCPowerSupplyModuleButtonDescriptionON(—)Powersonthepowersupplymodule.OFF(O)Powersoffthepowersupplymodule.TechnicalParametersForthetechnicalparametersoftheDCpowersupplymoduleoftheZXR102800-4,refertoTable3-8.Table3-8TechnicalParametersoftheDCPowerSupplyModuleoftheZXR102800-4ParameterSpecicationDimensions(height×width×depth)3.15in.×1.57in.×6.89in.(80mm×40mm×175mm)Weight1.45lb.(0.52kg)Inputvoltagerange-72VDCto-38VDCMaximumoutputpower250WRatedinputcurrent8.5A3.3FanThereisaverticalfanmoduleintheZXR102800-4chassis,whichconsistsoftwofans.Thecoolairentersthechassisfromitslateralside,owstotheboardsandpowersupplymodules,andthenisblownoutfromtheotherside.Thefanmodulecanautomaticallyadjustthefanspeedaccordingtotheequipmentoperationandsupportsthestatusmonitoringandalarmfunctions.ForthetechnicalspecicationsoftheZXR102800-4fanmodule,refertoTable3-9.Table3-9ZXR102800-4FanSpecicationsParameterSpecicationSize(W×H×D)40.8mm×81.1mm×186mmWeight0.44kgPowerconsumption30WMaximumwindpressure23mmH2OMaximumwind191CFM3-6SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter3ZXR102800-4ChassisParameterSpecicationMaximumnoise58dBAOperationvoltage12V3-7SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionThispageintentionallyleftblank.3-8SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter4ZXR101800-2SChassisTheZXR10ZSRV2seriesroutersarehighlyexiblebyusingthemodularstructure,andtheboardsandcomponentsarehotswappable.Theentirerouterconsistsofthechassis,backplane,MPFU,lineinterfaceboards,powersupplymodules,andfanmodules.TheZXR101800-2Sisadesktopproduct.ThepowersupplymoduleandMPFUarexedinthechassis.Theserviceboardsareinstalledontherearpanelandtherearleading-outmodeisused.TheZXR101800-2Shastwoextensiontypesconguredwithwirelessmodules:ZXR101800-2S(G)andZXR101800-2S(W).lTheZXR101800-2S(G)hasabuilt-inLTEmodule,whereaSIMcardslotisavailableforsupportingGSM,WCDMA,TD-SCDMA,orLTEnetworks.lTheZXR101800-2S(W)hasabuilt-inWiFimoduleforsupportingtheWiFifunction.TableofContentsStructure....................................................................................................................4-1PowerSupply.............................................................................................................4-64.1Structure4.1.1OverviewandStructureOverviewTheheightoftheZXR101800-2Schassis(excludingtheantenna)is1U(1U=44.45mm),andthedimension(width×height×depth)380mm×43.6mm×200mm.ForadescriptionofthemaincomponentsoftheZXR101800-2S,refertoTable4-1.Table4-1DescriptionsoftheMainComponentsoftheZXR101800-2SComponentNameDescriptionBoardareaTheZXR101800-2Sprovidesamaximumoftwolineinterfacecardslots.MPFUTheMPFUoftheZXR101800-2Sisintegratedintothechassisandcannotberemoved.PowersupplymoduleThepowersupplymoduleoftheZXR101800-2Sisintegratedonthedevice,andcannotberemovedorinstalled.4-1SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionFrontPanelFigure4-1showsthefrontviewoftheZXR101800-2S.Figure4-1ZXR101800-2SFrontViewNote:BothoftheZXR101800-2S(G)andtheZXR101800-2S(W)supportthewirelessfunction.Eachofthemisconguredwithawirelessmoduleandapairofantennas.Ifnowirelessmoduleiscongured,thechassishasnoantenna.Figure4-2showsthepanelviewoftheZXR101800-2S.Figure4-2ZXR101800-2SFrontPanelForadescriptionoftheZXR101800-2Sfrontpanel,refertoT able4-2.Table4-2ZXR101800-2SFrontPanelDescriptionsComponentSilkScreenNameDescriptionUSB1 USBinterfacesUSB2USB2.0interface,usedforstoringinstallationpackagesandotherdata,supporting3GextensionandcommissioningthroughUSB.4-2SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter4ZXR101800-2SChassisComponentSilkScreenNameDescriptionALMAlarmindicator,red.PWRPowersupplyindicator,green.SYSSystemoperationindicator,green.IndicatorsWIFI/WWANWirelessoperationindicator,greenlIfaWiFimoduleiscongured,WIFIisdisplayedontheindicatorlabel.ThisindicatorindicateswhethertheWiFifunctionoperatesproperly.lIfanLTEmoduleiscongured,WWANisdisplayedontheindicatorlabel.ThisindicatorindicateswhethertheLTEfunctionoperatesproperly.RSTResetbutton.WIFIWiFifunctionbutton,whichisavailableonlyonthechassisoftheZXR101800-2S(W).ButtonsWPSWiFiconnectionreestablishmentbutton,whichisavailableonlyonthechassisoftheZXR101800-2S(W).Note:TheZXR101800-2SwithoutanywirelessmoduledoesnothavetheWIFIindicator,WIFIbutton,orWPSbutton.RearPanelFigure4-3showstherearpaneloftheZXR101800-2S.Figure4-3ZXR101800-2SRearPanel4-3SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionNote:BothoftheZXR101800-2S(G)andtheZXR101800-2S(W)supportthewirelessfunction.Eachofthemisconguredwithawirelessmoduleandapairofantennas.Ifnowirelessmoduleiscongured,thechassishasnoantenna.ForadescriptionoftheZXR101800-2Srearpanel,refertoT able4-3.Table4-3ZXR101800-2SRearPanelDescriptionsComponentSilkScreenNameDescriptionANT1–2AntennainterfaceAntennaslot,whereanantennaisinstalledifawirelessmoduleiscongured.OAMNetworkinterface(RJ45)Networkport(10M/100M/1000M)usedforsystemmaintenanceandprogramdownloading.CONMicroUSBinterfaceMicroUSBconsoleinterface.ThefunctionsarethesameasthoseoftheRJ45CON/AUXinterface.EitheroftheMicroUSBconsoleinterfaceortheRJ45CON/AUXinterfaceisused.Thepriorityishigh.CON/AUXSerialport(RJ45)Debuggingportforsystemmanagementandconguration.GE1–4GEelectricalinterface4GEelectricalinterfaces.COMBO,GE5–6Combointerface2electrical/opticalcombointerfaces.SIMCARDSIMcardinterfaceSIMcardinterfaceforsupportingGSM,CDMA2000,WCDMA,TD-SCDMA,orLTEnetworks.LNK/ACTIndicatorLinkstatusindicatorsingreenforthetwoCombointerfaces.4.1.2SlotLayoutForafrontviewoftheZXR101800-2Schassis,seeFigure4-4.Figure4-4FrontViewoftheZXR101800-2SChassisTheZXR101800-2Schassisprovidestwoserviceslotsandboardsarehorizontallyinstalledinthechassis.4-4SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter4ZXR101800-2SChassislBoththepowermoduleandtheMPFUareintegratedintothedevice.Theycannotberemoved.lSPIUsareinstalledinslots0and1.4.1.3SystemParametersForthesystemparametersoftheZXR101800-2S,refertoT able4-4.Table4-4SystemParametersoftheZXR101800-2SParameterSpecicationDimensions(width×height×depth)14.96in.×1.72in.×7.88in.(380mm×43.6mm×200mm)Weight(fullconguration)<6.83lb.(3.10kg)PhysicalparameterMaximumpowerconsumption<55WSupportedfrequencyband2.4G WiFifunctionSupportedsystemstandardIEEE802.11b/g/nMemory2GB StoragecapacityFLASH1GBTotalnumberofslots2 SlotNumberofPIUslots2Maximumoutputpower60WRatedinputvoltage-60VDCto-48VDCDCpower(single)Inputvoltagerange-72VDCto-38VDCRatedinputvoltage100VACto240VACInputfrequencyrange50Hz–60HzACpower(single)Ratedoutputpowerpermodule60WGroundingresistanceResistanceofjointgrounding<5Ω4-5SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescription4.2PowerSupplyFunctionTheZXR10ZSRV2seriesrouterssupport100Vto240V,50Hzto60HzACpowersupplyand-72Vto-38VDCpowersupply.TheZXR101800-2SuseseitheroneACpowersupplyoroneDCpowersupply,andthepowersupplymodulesarenothotswappable.Apowersupplymoduleprovidesthefollowingfunctions:lInput/outputover/undervoltagealarmandprotection.lOutputovercurrentalarmandprotection.lTemperaturealarmandoverheatingprotection.ButtonsThereisonepowerbuttonontheZXR101800-2Spowersupplymodule,seeFigure4-5.Foradescriptionofthebutton,refertoT able4-5.Figure4-5PowerButtonTable4-5PowerButtonDescriptionfortheZXR101800-2SACPowerSupplyModuleButtonDescriptionONPowersonthepowersupplymodule.OFFPowersoffthepowersupplymodule.TechnicalParametersForthetechnicalparametersoftheACpowerrectieroftheZXR101800-2S,refertoT able4-6.Table4-6TechnicalParametersoftheACPowerRectieroftheZXR101800-2SParameterSpecicationInputvoltagerange100VACto240VACACinputfrequency50Hz–60HzRatedoutputpower60WForthetechnicalparametersoftheDCpowerrectieroftheZXR101800-2S,refertoT able4-7.4-6SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter4ZXR101800-2SChassisTable4-7TechnicalParametersoftheDCPowerRectieroftheZXR101800-2SParameterSpecicationInputvoltagerange-72VDCto-38VDCRatedoutputpower60W4-7SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionThispageintentionallyleftblank.4-8SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter5ZXR102800-3EChassisTheZXR10ZSRV2serialroutershaveastructuredesignedbasedonmodularization.Theboardsandcomponentssupportonlinehotswappingandhaveaexibleexpendability.AZXR102800-3Echassisiscomposedofasubrack,abackplane,acontrollingandtransferringunit,lineinterfaceboards,powermodules,andfanmodules.TheZXR102800-3Esubrackhasasheetmetalstructure.WhereinthecontrollingandtransferringunitandfanmodulesarexedonaZXR10ZSRV2router,theserviceboardandpowermodulesareinstalledattheback,cablesareledoutfromtheback,andthreelineinterfaceboardscanbeinstalled.TheentireZXR102800-3Echassishasastandardwidthof19"andcanbeinstalledintoastandardIEC297cabinetoranETSIcabinet.AZXR102800-3E(G)submodelcanbederivedfromaZXR102800-3Echassisbyexpandingthewirelessfunctionmodule.TheZXR102800-3E(G)submodelhasa3GorLTEmoduleinsideandaslotforaSIMcardonthepanel,supportingaGSM,WCDMA,TD-SCDMA,orLTEnetwork.TableofContentsStructure....................................................................................................................5-1PowerSupplies..........................................................................................................5-55.1Structure5.1.1OverviewandStructureOverviewAchassisofaZXR102800-3Erouterhasaheight(withouttheantenna)ofabout1U(1U=44.45mm),andadimensionof442mm×44mm×440mm(width×height×depth).Foritscomponentsanddescriptions,refertoT able5-1.Table5-1MainComponentsofaZXR102800-3EChassisComponentDescriptionControllingandtransferringboardIntegratedontherouterandcannotbepluggedorunplugged.BoardsTheZXR102800-3Echassisprovidesthreeslotsforlineinterfaceboards.PowermodulesTheZXR102800-3Echassisprovidestwoslotsforoneortwopowermodules.5-1SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionFrontPanelThefollowingdescribesthefrontviewandfrontpanelofaZXR102800-3Echassis.lFigure5-1showsthefrontviewofaZXR102800-3Echassis.Figure5-1FrontStructureGraphforaZXR102800-3EChassisNote:TheZXR102800-3E(G)submodeloftheZXR102800-3Echassissupportsthewirelessfunction,withabuilt-inwirelessmoduleandantennas.Ifthewirelessmoduleisnotcongured,thechassisdoesnothaveanantenna.lFigure5-2showsthefrontpanelofaZXR102800-3Echassis.Figure5-2FrontPanelofaZXR102800-3EChassisForadescriptionofthefrontpanel,refertoTable5-2.Table5-2DescriptionsofInterfacesontheFrontPanelofaZXR102800-3EChassisPartTypeDescriptionAntennainterfaceAntennaslot.GEinterface24GEelectricalinterfaces,supportingtherouteswitchingfunction.COMBOinterfacesTwoCombointerfaces.USBinterfacesUSB2.0interfaces,whichareusedtostoreapplicationsandotherdataandsupportcommissioning.Networkinterface(RJ45)Maintenancenetworkinterface(10M/100M/1000M),whichisusedforsystemcontrolandapplicationdownload.5-2SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter5ZXR102800-3EChassisPartTypeDescriptionMicroUSBinterfacesConsoleinterfacesoftheMicroUSBmodel,whichhavethesamefunctionsasthoseoftheCON/AUXinterfacesoftheRJ45modelbutahigherpriority.Selecteitherone.Serialinterface(RJ45)Debuggingserialinterfaces(Console/AUXinterfaces)oftheRJ45model,whichareusedfordevicemanagementandfunctionconguration.InterfaceforaSIMcardInterfacefora3GorLTESIMcard.WIFIfunctionbutton.Buttonforre-establishingaWIFIconnection.ButtonsSystemresetbutton.GreenindicatorsforlinkstatusoftwoCombointerfaces.Redindicatorforsystemfaults.Greenindicatorforsystemoperationstatus.IndicatorsGreenindicatorfortheoperationstatusofthe3GorLTEnetwork.BackPanelFigure5-3showsthebackpanelofaZXR102800-3Echassis.Figure5-3BackPanelofaZXR102800-3EChassis1.SlotforaninterfaceboardoftheSPIUline2.Powermodule3.SlotforaninterfaceboardofthePIU/SPIUline5.1.2SlotDeploymentFigure5-4showsslotsandslotIDsonthebackofaZXR102800-3Echassis.Figure5-4SlotsontheBackofaZXR102800-3EChassis5-3SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionAZXR102800-3Echassishasastructuresuitableforhorizontalinstallation.Threeserviceboardslotsaredesignedforthechassis,whicharenumberedas0-2inorder.Wherein:lSlot0isusedforanSPIUinterfaceboard.lSlot1isusedanSPIUinterfaceboard.lSlot2isusedaPIUorDPIUinterfaceboard.5.1.3SystemParametersForsystemparametersofaZXR102800-3Echassis,refertoT able5-3.Table5-3SystemParametersofaZXR102800-3EChassisItemPhysicalParametersDimension(width×height×depth)17.41in.×1.73in.×17.32in.(442mm×44mm×440mm)Weight(withfullconguration)<19.0lb.(8.6kg)PhysicalParametersMaximumpowerconsumption<120WMemory2GB StoragecapacityFlash4GBNumberofslots5 SlotNumberofslotsforlineinterfaceboards3Redundancybackup1+1redundancybackup,supportingbothACandDCpowers.Ratedoutputpower250WRatedinputvoltageFrom-60VDCto-48VDCDCpower(single)RangeofthemaximuminputvoltageFrom-72VDCto-38VDCRedundancybackup1+1redundancybackup,supportingbothACandDCpowers.Ratedinputvoltage100VAC–240VACRangeoftheinputfrequency50Hz–60HzACpower(single)Ratedoutputpower250WGroundingresistanceGroundingresistancewithcommonearthing,whichislowerthan5Ω.5-4SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter5ZXR102800-3EChassis5.2PowerSuppliesZXR10ZSRV2serialrouterssupportavoltagewithintherangeof100V–240V,ACpowerof50Hz–60Hz,andDCpowerfrom-38Vto-72V.The1+1dual-powerredundancymodeandpowersupplyswappingareavailable.Thepowermoduleshavethefollowingfunctions:lAlarmsaregeneratedduetoahighinputoroutputvoltage.lAlarmsaregeneratedduetoahighoutputcurrent.lAlarmsaregeneratedduetoahighorlowtemperature.Caution!TurnoffbothpowersuppliesbeforeinstallingandmaintainingtheZXR10ZSRV2.5.2.1ACPowerModulePanelFigure5-5showsthepaneloftheACpowermoduleofaZXR102800-3Echassis.Figure5-5PaneloftheACPowerModuleIndicatorsForfunctionsoftheindicatorsontheACpowermoduleoftheZXR102800-3Echassis,refertoT able5-4.Table5-4FunctionsoftheIndicatorsonthePaneloftheACPowerModuleoftheZXR102800-3EChassisIndicatorNumberColorDescriptionRUN1GreenThepowermoduleisoperatingproperly.ALM1RedThepowermoduleisoperatingimproperly.ButtonsForfunctionsofthepowerbuttonsontheACpowermoduleoftheZXR102800-3Echassis,refertoT able5-5.5-5SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionTable5-5FunctionsofthePowerButtonsoftheACPowerModuleoftheZXR102800-3EChassisButtonDescriptionON(—)DialthebuttontoONtoturnonthemodule.OFF(O)DialthebuttontoOFFtoturnoffthepower.TechnicalParametersFortechnicalparametersofarectieroftheACpowermoduleoftheZXR102800-3Echassis,refertoTable5-6.Table5-6TechnicalParametersoftheACPoweroftheZXR102800-3EChassisParameterDescriptionDimension(width×height×depth)3.15in.×1.57in.×6.89in.(80mm×40mm×175mm)Weight0.68kgRangeoftheinputvoltage100VAC–240VACInputACfrequency50Hz–60HzRatedoutputpower250W5.2.2DCPowerModulePanelFigure5-6showsthepaneloftheDCpowermoduleofaZXR102800-3Echassis.Figure5-6PaneloftheDCPowerModuleIndicatorsForfunctionsoftheindicatorsontheDCpowermoduleoftheZXR102800-3Echassis,refertoT able5-7.5-6SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter5ZXR102800-3EChassisTable5-7FunctionsoftheIndicatorsonthePaneloftheDCPowerModuleoftheZXR102800-3EChassisIndicatorNumberColorDescriptionRUN1GreenThepowermoduleisoperatingproperly.ALM1RedThepowermoduleisoperatingimproperly.ButtonsForfunctionsofthepowerbuttonsontheDCpowermoduleoftheZXR102800-3Echassis,refertoT able5-8.Table5-8FunctionsofthePowerButtonsoftheDCPowerModuleoftheZXR102800-3EChassisButtonDescriptionON(—)DialthebuttontoONtoturnonthemodule.OFF(O)DialthebuttontoOFFtoturnoffthepower.TechnicalParametersFortechnicalparametersoftheDCpowermoduleoftheZXR102800-3Echassis,refertoTable5-9.Table5-9TechnicalParametersoftheDCPowerModuleoftheZXR102800-3EChassisParameterDescriptionDimension(width×height×depth)3.15in.×1.57in.×6.89in.(80mm×40mm×175mm)Weight0.52kgRangeoftheinputvoltageFrom-72VDCto-38VDCRatedoutputpower250WRatedinputcurrent8.5A5-7SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionThispageintentionallyleftblank.5-8SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter6ZXR101800-2EChassisZXR10ZSRV2seriesroutershaveamodularstructure.Theboardsandcomponentssupporthotswappingandhaveexibleexpandability.AZXR102800-3Echassisiscomposedofasubrack,abackplane,acontrollingandtransferringunit,lineinterfaceboards,powermodules,andfanmodules.AZXR101800-2Esubrackhasasheetmetalstructure.Thecontrollingandtransferringunitandfanmodulesarexedontherouter,serviceboardandpowermodulesareinstalledattheback,cablesareledoutfromtheback,andtwolineinterfaceboardscanbeinstalled.AZXR101800-2Echassishasastandardwidthof19"andcanbeinstalledintoastandardIEC297cabinetoranETSIcabinet.AZXR101800-2E(G)submodelcanbederivedfromaZXR101800-2Echassisbyexpandingthewirelessfunctionmodule.AZXR101800-2E(G)hasa3GorLTEmoduleinsideandaslotforaSIMcardonthepanel,supportingaGSM,WCDMA,TD-SCDMA,orLTEnetwork.TableofContentsStructure....................................................................................................................6-1PowerSupplies..........................................................................................................6-46.1Structure6.1.1OverviewandStructureOverviewAchassisofaZXR101800-2Erouterhasaheight(withouttheantenna)ofabout1U(1U=44.45mm),andadimensionof442mm×44mm×440mm(width×height×depth).Foritscomponentsanddescriptions,refertoT able6-1.Table6-1MainComponentsofaZXR101800-2EChassisComponentDescriptionControllingandtransferringboardThecontrollingandtransferringboardofaZXR101800-2Echassisisintegratedontherouterandcannotbepluggedorunplugged.BoardTheZXR101800-2Echassisprovidestwoslotsforlineinterfaceboards.PowermoduleTheZXR101800-2Echassisprovidestwoslotsforoneortwopowermodules.6-1SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionFrontViewThefollowingdescribesthestructureofaZXR101800-2Echassisanditsfrontpanel.lFigure6-1showsthefrontviewofaZXR101800-2Echassis.Figure6-1FrontViewofaZXR101800-2EChassisNote:TheZXR101800-2E(G)submodeloftheZXR101800-2Echassissupportsthewirelessfunction,withabuilt-inwirelessmoduleandanantenna.Ifthewirelessmoduleisnotcongured,thechassisdoesnothaveanantenna.lFigure6-2showsthefrontpanelofaZXR101800-2Echassis.Figure6-2FrontPanelofaZXR101800-2EChassisForadescriptionofthefrontpanel,refertoTable6-2.Table6-2DescriptionsofInterfacesontheFrontPanelofaZXR101800-2EChassisComponentTypeDescriptionAntennainterfacesAntennaslots.GEinterfaces24GEelectricalinterfaces.COMBOinterfacesTwoCombointerfaces.USBinterfacesUSB2.0interfaces,whichareusedtostoreapplicationsandotherdataandsupportcommissioning.Networkinterfaces(RJ45)Maintenancenetworkinterfaces(10M/100M/1000M),whichareusedtocontrolthesystemanddownloadapplications.6-2SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter6ZXR101800-2EChassisComponentTypeDescriptionMicroUSBinterfacesConsoleinterfacesoftheMicroUSBmodel,whichhavethesamefunctionsasthoseoftheCON/AUXinterfacesoftheRJ45modelbutahigherpriority.Selecteitherone.Serialinterfaces(RJ45)Debuggingserialinterfaces(Console/AUXinterfaces)oftheRJ45model,whichareusedtomanageroutersandcongurefunctions.InterfaceforaSIMcardInterfacefora3GorLTESIMcard.WIFIfunctionbutton.Buttonforre-establishingaWIFIconnection.ButtonsSystemresetbutton.GreenindicatorsforlinkstatusesoftwoCombointerfaces.Redindicatorforsystemfaults.Greenindicatorforsystemoperationstatus.IndicatorsGreenindicatorfortheoperationstatusofa3GorLTEnetwork.BackPanelFigure6-3showsthebackpanelofaZXR101800-2Echassis.Figure6-3BackPanelofaZXR101800-2EChassis1.SlotsforSPIUlineinterfaceboards2.Powermodules6.1.2SlotsFigure6-4showsslotsandslotIDsonthebackofaZXR101800-2Echassis.Figure6-4SlotsontheBackofaZXR101800-2EChassisAZXR101800-2Echassishasastructuresuitableforhorizontalinstallation.Twoserviceboardslotsaredesignedforthechassis,whicharenumberedas0-1inorder.Slots0and1areusedtoinstallSPIUinterfaceboards.6-3SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescription6.1.3SystemParametersForsystemparametersofaZXR101800-2Erouter,refertoTable6-3.Table6-3SystemParametersofaZXR101800-2EChassisItemPhysicalParametersDimension(width×height×depth)17.41in.×1.73in.×17.32in.(442mm×44mm×440mm)Weight(withfullconguration)<19.0lb.(8.6kg)PhysicalParametersMaximumpowerconsumption<80WMemory2GB StoragecapacityFLASH1GBNumberofslots4 SlotNumberofslotsforlineinterfaceboards2Redundancybackup1+1redundancybackup,supportingbothACandDCRatedoutputpower250WRatedinputvoltageFrom-60VDCto-48VDCDCpower(single)RangeofthemaximuminputvoltageFrom-72VDCto-38VDCRedundancybackup1+1redundancybackup,supportingbothACandDCRatedinputvoltage100VAC–240VACRangeoftheinputfrequency50Hz–60HzACpower(single)Ratedoutputpower250WGroundingresistanceGroundingresistancewithcommonearthing,whichislowerthan5Ω6.2PowerSuppliesZXR10ZSRV2serialrouterssupportavoltagewithintherangeof100V–240V,ACpowerof50Hz–60Hz,andDCpowerfrom-38Vto-72V.The1+1dual-powerredundancymodeandpowersupplyswappingareavailable.Thepowermoduleshavethefollowingfunctions:lAlarmsaregeneratedduetoahighorlowinputoroutputvoltage.6-4SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter6ZXR101800-2EChassislAlarmsaregeneratedduetoahighoutputcurrent.lAlarmsaregeneratedduetoahighorlowtemperature.Caution!TurnoffbothpowersuppliesbeforeinstallingandmaintainingtheZXR10ZSRV2.6.2.1ACPowerModulePanelFigure6-5showsthepaneloftheACpowermoduleofaZXR101800-2Echassis.Figure6-5PaneloftheACPowerModuleIndicatorsForfunctionsoftheindicatorsontheACpowermoduleoftheZXR101800-2Echassis,refertoT able6-4.Table6-4FunctionsoftheIndicatorsonthePaneloftheACPowerModuleoftheZXR101800-2EChassisIndicatorNumberColorDescriptionRUN1GreenThepowermoduleisoperatingproperly.ALM1RedThepowermoduleisoperatingimproperly.ButtonsForfunctionsofthepowerbuttonsontheACpowermoduleoftheZXR101800-2Echassis,refertoT able6-5.Table6-5FunctionsofthePowerButtonsoftheACPowerModuleoftheZXR101800-2EChassisButtonDescriptionON(—)DialthebuttontoONtoturnonthemodule.OFF(O)DialthebuttontoOFFtoturnoffthepower.6-5SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionTechnicalParametersFortechnicalparametersoftherectieroftheACpowermoduleoftheZXR101800-2Echassis,refertoTable6-6.Table6-6TechnicalParametersoftheACPoweroftheZXR101800-2EChassisParameterDescriptionDimension(width×height×depth)3.15in.×1.57in.×6.89in.(80mm×40mm×175mm)Weight0.68kgRangeoftheinputvoltage100VAC–240VACInputACfrequency50Hz–60HzRatedoutputpower250W6.2.2DCPowerModulePanelFigure6-6showsthepaneloftheDCpowermoduleofaZXR101800-2Echassis.Figure6-6PaneloftheDCPowerModuleIndicatorsForfunctionsoftheindicatorsontheDCpowermoduleoftheZXR101800-2Echassis,refertoT able6-7.Table6-7FunctionsoftheIndicatorsonthePaneloftheDCPowerModuleoftheZXR101800-2EChassisIndicatorNumberColorDescriptionRUN1GreenThepowermoduleisoperatingproperly.ALM1RedThepowermoduleisoperatingimproperly.ButtonsForfunctionsofthepowerbuttonsontheDCpowermoduleoftheZXR101800-2Echassis,refertoT able6-8.6-6SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter6ZXR101800-2EChassisTable6-8FunctionsofthePowerButtonsoftheDCPowerModuleoftheZXR101800-2EChassisButtonDescriptionON(—)DialthebuttontoONtoturnonthemodule.OFF(O)DialthebuttontoOFFtoturnoffthepower.TechnicalParametersFortechnicalparametersoftheDCpowermoduleoftheZXR101800-2Echassis,refertoTable6-9.Table6-9TechnicalParametersoftheDCPowerModuleoftheZXR101800-2EChassisParameterDescriptionDimension(width×height×depth)3.15in.×1.57in.×6.89in.(80mm×40mm×175mm)Weight0.52kgRangeoftheinputvoltageFrom-72VDCto-38VDCRatedoutputpower250WRatedinputcurrent8.5A6-7SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionThispageintentionallyleftblank.6-8SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter7MPFUTheManagementandPacketForwardingUnit(MPFU)isthecontrolnodeoftherouter.TheMPFUforwardspacketsandmanagesandmaintainstheentiredevice.TheMPFUconsistsofthepacketforwardingmodule,managementandcontrolmodule,clockprocessingmodule,andalarmmonitoringmodule.Itforwardspackets,andmanagesthesystemclocksource,controlplane,systemmaintenanceplaneandenvironmentalmonitoringplane.lThepacketforwardingmoduleclassiesandforwardsthepacketsthatthelineinterfaceboardsreceiveandcontrolsthepackettrafc.lThemanagementandcontrolmoduleprovidesthefollowingfunctions:àProcessesprotocolsandsignalingmessagestocontrolandnotifythesystemstatus.Therouteprotocolcontrollayerandthecongurationandoperationlayerareseparatedtoenhancethecontrollayerstabilityandequipmentmanageability.àConguresandmaintainsthesystemstatus.Itprovidesthesystemdatacongurationandupgradefunctionsandsystemoperationlogs.Itsupportstwotypesofmanagementinterfaces:serialportandRJ45port.lThealarmmonitoringmodulemonitorstheoperationconditionsoftheboards,powersupplymodules,andfanmodulesandgeneratesalarmswhennecessary.Itprovidesauser-friendlyman-machineinterfacethroughtheCLIorSNMPnetworkmanagementsystem.TheMPFUoftheZXR102800-3E,ZXR101800-2EorZXR101800-2Sisintegratedintothechassisandcannotberemoved.TheMPFUboardsoftheZXR102800-4andZXR103800-8canbedividedintothreetypes:RAC-2838-MPFU-A,RAC-2838-MPFU-B,andRAC-2838-MPFU-C.TableofContentsRAC-2838-MPFU-A....................................................................................................7-1RAC-2838-MPFU-B/RAC-2838-MPFU-C...................................................................7-37.1RAC-2838-MPFU-AOverviewRAC-2838-MPFU-AisthetypeAMPFUoftheZXR102800-4andZXR103800-8.TheMPFUprovidesthefollowingfunctions:lSupportshotswappingwithamodularstructure.7-1SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionlSupportsseparationoftheforwardingplaneandcontrolplane.PanelForthepaneloftheRAC-2838-MPFU-A,seeFigure7-1.Figure7-1PaneloftheRAC-2838-MPFU-AInterfacesForadescriptionoftheinterfacesoftheRAC-2838-MPFU-A,refertoT able7-1.Table7-1DescriptionoftheInterfacesoftheRAC-2838-MPFU-AInterfaceTypeSilkScreenNameDescriptionNetworkinterface(RJ45)OAMNetworkport(10M/100M/1000M)usedforsystemmaintenanceandprogramdownloadingCONSOLEDebuggingportforsystemmanagementandcongurationSerialport(RJ45)AUXDebuggingserialportofaPIUandModemconvergenceportUSB1 USBinterfaceUSB2USB2.0interface,whichtransmitstheprogramdataandotherdataGEelectronicinterfaceGE3–6FourGEelectronicinterfacesCOMBOinterfaceCOMBO1/2,GE1–2TwoCOMBOinterfacesIndicatorsForadescriptionoftheLEDindicatorsonthepaneloftheRAC-2838-MPFU-A,refertoTable7-2.Table7-2IndicatorDescriptionsfortheRAC-2838-MPFU-AIndicatorNumberColorDescriptionRUN1GreenTheindicatorislitwhentheboardisoperatingproperly.ALM1RedTheindicatorislitiftheboardisnotoperatingproperly.LINK/ACT2GreenLinkstateindicatorsofCOMBOinterfaces.7-2SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter7MPFUButtonsForadescriptionoftheRSTbuttononthepaneloftheRAC-2838-MPFU-A,refertoT able7-3.Table7-3RSTButtonDescriptionfortheRAC-2838-MPFU-AButtonDescriptionRSTResetstheboard.TechnicalParametersForthetechnicalparametersoftheRAC-2838-MPFU-A,refertoT able7-4.Table7-4TechnicalParametersoftheRAC-2838-MPFU-AParameterSpecicationSilkscreennameRAC-2838-MPFU-ADimensions(H×W×D)11.7in.×1.58in.×6.9in.(296.3mm×40.24mm×175mm)Powerconsumption35WWeight2.38lb.(1.08kg)7.2RAC-2838-MPFU-B/RAC-2838-MPFU-COverviewTheRAC-2838-MPFU-BandRAC-2838-MPFU-CareMPFUboardsoftheZXR102800-4andZXR103800-8.lTheRAC-2838-MPFU-BandRAC-2838-MPFU-CwithdifferentforwardingcapacityareprovidedfortheZXR102800-4andZXR103800-8.lBothofthemsupporthotswappingwithamodularstructure.lBothofthemsupportseparationoftheforwardingplaneandcontrolplane.PanelTheRAC-2838-MPFU-BandRAC-2838-MPFU-Chavethesameoverviewexceptthesilkscreenname.ForanoverviewoftheRAC-2838-MPFU-B/RAC-2838-MPFU-C,seeFigure7-2.Figure7-2RAC-2838-MPFU-BandRAC-2838-MPFU-C7-3SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionInterfacesForadescriptionoftheinterfacesoftheRAC-2838-MPFU-B/RAC-2838-MPFU-C,refertoTable7-5.Table7-5DescriptionoftheInterfacesoftheRAC-2838-MPFU-B/RAC-2838-MPFU-CInterfaceTypeSilkScreenNameDescriptionNetworkinterface(RJ45)OAMNetworkport(10M/100M/1000M)usedforsystemmaintenanceandprogramdownloadingCONSOLEDebuggingportforsystemmanagementandcongurationSerialport(RJ45)AUXDebuggingserialportofaPIUandModemconvergenceportUSB1USBinterfaceUSB2USB2.0interface,whichtransmitstheprogramdataandotherdataGEelectronicinterfaceGE5–6TwoGEelectronicinterfacesCOMBOinterfaceCOMBO1/2,COMBO3/4,GE1–4FourCOMBOinterfacesIndicatorsForadescriptionoftheLEDindicatorsonthepaneloftheRAC-2838-MPFU-B/RAC-2838-MPFU-C,refertoT able7-6.Table7-6DescriptionoftheIndicatorsonthePaneloftheRAC-2838-MPFU-B/RAC-2838-MPFU-CIndicatorNumberColorDescriptionRUN1GreenTheindicatorislitwhentheboardisoperatingproperly.ALM1RedTheindicatorislitiftheboardisnotoperatingproperly.LINK/ACT4GreenLinkstateindicatorsofCOMBOinterfaces.ButtonsForadescriptionoftheRSTbuttononthepaneloftheRAC-2838-MPFU-B/RAC-2838-MPFU-C,refertoT able7-7.Table7-7DescriptionoftheRSTButtononthePaneloftheRAC-2838-MPFU-B/RAC-2838-MPFU-CButtonDescriptionRSTResetstheboard.7-4SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter7MPFUTechnicalParametersForthetechnicalparametersoftheRAC-2838-MPFU-B/RAC-2838-MPFU-C,refertoTable7-8.Table7-8TechnicalParametersoftheRAC-2838-MPFU-B/RAC-2838-MPFU-CParameterSpecicationSilkscreennameRAC-2838-MPFU-B/RAC-2838-MPFU-CDimensions(H×W×D)11.7in.×1.58in.×6.9in.(296.3mm×40.24mm×175mm)Powerconsumption35WWeight2.38lb.(1.08kg)7-5SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionThispageintentionallyleftblank.7-6SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter8GeneralProcessingBoardsGeneralprocessingboardsareinstalledinslotsforfull-heightDPIUinterfacecardsandusedtoclassifyandmonitormessagesfromthemaincontrolboard.TableofContentsRAC-DPIU-OSU-A1...................................................................................................8-1RAC-DPIU-OSU-A2...................................................................................................8-3RAC-DPIU-FW-A........................................................................................................8-48.1RAC-DPIU-OSU-A1OverviewAsthegeneralprocessingboardoftheZXR102800-4andZXR103800-8,anRAC-DPIU-OSU-A1boardisinstalledinaslotforafull-heightDPIUinterfacecardandhasthefollowingfunctions:lClassies,monitors,lters,andtransfersreceivedmessagesdependingonapplications.lProvidesfourlinesofhigh-speedserialinterfacesfortheinternalgigabitEthernetandonelineofelectricalinterfacefortheexternalgigabitEthernet.lGEelectricalinterfacessupport10BASE-T/100BASE-TX/1000BASE-T .PanelForthepaneloftheRAC-DPIU-OSU-A1boardofthegeneralprocessingboard,seeFigure8-1.Figure8-1PanelofanRAC-DPIU-OSU-A1BoardInterfacesForadescriptionofinterfacesontheRAC-DPIU-OSU-A1board,refertoTable8-1.8-1SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionTable8-1DescriptionsofInterfacesontheRAC-DPIU-OSU-A1BoardInterfaceTypeDescriptionNetworkinterface(RJ45)Servicenetworkinterface,a10/100/1000BASE-Telectricalinterface.Serialinterface(RJ45)SerialinterfaceinterconnectedwithaPC.VGAinterface(DB15)X86VGAoutputinterface.USBinterfacesUSB2.0interfacesusedtoinstalltheX86system.IndicatorsTheRAC-DPIU-OSU-A1boardprovidesmultipleLEDindicatorsonitspanel.Fortheirfunctions,refertoTable8-2.Table8-2FunctionsoftheIndicatorsonthePaneloftheRAC-DPIU-OSU-A1BoardIndicatorColorDescriptionALMRedIfthisindicatorissolidonorashing,theboardisfaulty.RUNGreenIndicatesthattheboardisoperatingproperly.ButtonsTheRAC-DPIU-OSU-A1boardprovidestwobuttonsonitspanel.Fortheirfunctions,refertoTable8-3.Table8-3FunctionsoftheButtonsonthePaneloftheRAC-DPIU-OSU-A1BoardButtonDescriptionRSTBoardresetbuttonPWRBoardpowerbuttonTechnicalParametersFortechnicalparametersoftheRAC-DPIU-OSU-A1board,refertoTable8-4.Table8-4TechnicalParametersoftheRAC-DPIU-OSU-A1BoardParameterDescriptionBoardnamesilkscreenRAC-DPIU-OSU-A1Dimension(width×height×depth)7.76in.×1.58in.×6.9in.(197.2mm×40.24mm×175mm)Powerconsumption40WWeight2.71lb.(1.23kg)MemoryDefaultcapacity(byte)4Gor8G(optional)HarddiskDefaultcapacity(byte)500Gor1T(optional)8-2SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter8GeneralProcessingBoards8.2RAC-DPIU-OSU-A2OverviewAsthegeneralprocessingboardoftheZXR102800-4andZXR103800-8,anRAC-DPIU-OSU-A2boardisinstalledinaslotforafull-heightDPIUinterfacecardandhasthefollowingfunctions:lClassies,monitors,lters,andtransfersreceivedmessagesdependingonapplications.lProvidesfourlinesofhigh-speedserialinterfacesfortheinternalgigabitEthernetandonelineofelectricalinterfacefortheexternalgigabitEthernet.lGEelectricalinterfacessupport10BASE-T/100BASE-TX/1000BASE-T .PanelForthepaneloftheRAC-DPIU-OSU-A2boardofthegeneralprocessingboard,seeFigure8-2.Figure8-2PanelofanRAC-DPIU-OSU-A2BoardInterfacesForadescriptionofinterfacesontheRAC-DPIU-OSU-A2board,refertoTable8-5.Table8-5DescriptionofInterfacesontheRAC-DPIU-OSU-A2BoardInterfaceTypeDescriptionNetworkinterface(RJ45)Servicenetworkinterface,a10/100/1000BASE-Telectricalinterface.Serialinterface(RJ45)SerialinterfaceinterconnectedwithaPC.VGAinterface(DB15)X86VGAoutputinterface.USBinterfacesUSB2.0interfacesusedtoinstalltheX86system.IndicatorTheRAC-DPIU-OSU-A2boardprovidesmultipleLEDindicatorsonitspanel.Fortheirfunctions,refertoTable8-6.8-3SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionTable8-6FunctionsoftheIndicatorsonthePaneloftheRAC-DPIU-OSU-A2BoardIndicatorColorDescriptionALMRedIfthisindicatorissolidonorashing,theboardisfaulty.RUNGreenIndicatesthattheboardisoperatingproperly.ButtonTheRAC-DPIU-OSU-A2boardprovidestwobuttonsonitspanel.Fortheirfunctions,refertoTable8-7.Table8-7FunctionsoftheButtonsonthePaneloftheRAC-DPIU-OSU-A2BoardButtonDescriptionRSTBoardresetbuttonPWRBoardpowerbuttonTechnicalParametersFortechnicalparametersoftheRAC-DPIU-OSU-A2board,refertoTable8-8.Table8-8TechnicalParametersoftheRAC-DPIU-OSU-A2BoardParameterDescriptionBoardnamesilkscreenRAC-DPIU-OSU-A2Dimension(width×height×depth)7.76in.×1.58in.×6.9in.(197.2mm×40.24mm×175mm)Powerconsumption40WWeight2.71lb.(1.23kg)MemoryDefaultcapacity(byte)4Gor8G(optional)HarddiskDefaultcapacity(byte)500Gor1T(optional)8.3RAC-DPIU-FW-AOverviewAsarewallboardoftheZXR103800-8andZXR102800-4,anRAC-DPIU-FW-Aboardisinstalledinaslotforafull-heightDPIUinterfacecardandhasthefollowingfunctions:lClassies,monitors,lters,andtransfersreceivedmessagesdependingonapplications.lProvidesfourlinesofhigh-speedserialinterfacesfortheinternalgigabitEthernetandonelineofelectricalinterfacefortheexternalgigabitEthernet.lGEelectricalinterfacessupport10BASE-T/100BASE-TX/1000BASE-T .8-4SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter8GeneralProcessingBoardsPanelForthepaneloftheRAC-DPIU-FW-Aboard,seeFigure8-3.Figure8-3PanelofanRAC-DPIU-FW-ABoardInterfacesForadescriptionofinterfacesonaRAC-DPIU-FW-Aboard,refertoT able8-9.Table8-9DescriptionofInterfacesonanRAC-DPIU-FW-ABoardInterfaceTypeDescriptionNetworkinterface(RJ45)Servicenetworkinterface,a10/100/1000BASE-Telectricalinterface.Serialinterface(RJ45)SerialinterfaceinterconnectedwithaPC.VGAinterface(DB15)X86VGAoutputinterface.USBinterfacesUSB2.0interfacesusedtoinstalltheX86system.IndicatorsForfunctionsofLEDindicatorsonthepanelofaRAC-DPIU-FW-Aboard,refertoTable8-10.Table8-10FunctionsofIndicatorsonthePanelofanRAC-DPIU-FW-ABoardIndicatorColorDescriptionALMRedIfthisindicatorissolidonorashing,theboardisfaulty.RUNGreenIndicatesthattheboardisoperatingproperly.ButtonsAnRAC-DPIU-FW-Aboardhastwobuttonsonitspanel.Fortheirfunctions,refertoTable8-11.Table8-11FunctionsofButtonsonthePanelofanRAC-DPIU-FW-ABoardButtonDescriptionRSTBoardresetbutton.PWRBoardpowerbutton.8-5SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionTechnicalParametersFortechnicalparametersofanRAC-DPIU-FW-Aboard,refertoT able8-12.Table8-12TechnicalParametersofanRAC-DPIU-FW-ABoardParameterDescriptionBoardnamesilkscreenRAC-DPIU-FW-ADimension(width×height×depth)7.76in.×1.58in.×6.9in.(197.2mm×40.24mm×175mm)Powerconsumption35WWeight2.31lb.(1.05kg)MemoryDefaultcapacity(byte)4Gor8G(optional)HarddiskDefaultcapacity(byte)2G8-6SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsAlineinterfaceboardisanexternalinterfaceofawire-speedrouterandimplementstheaccessofinterfacesofvariousratesandtypes.Theboardprovidesoneormorehigh-speednetworkinterfaces.TheZXR10ZSRV2providesvariouslineinterfaceboardsandsupportsvariousinterfaceratesandportdensitytomeettherequirementsofdifferentnetworksandservices.ForthetypesoflineinterfaceboardsthattheZXR10ZSRV2seriesrouterssupport,refertoTable9-1.Table9-1LineInterfaceBoardTypesTypeDimensions(Width×Height×Depth)ApplicableDeviceSlotDPIU(full-height)7.76in.×1.58in.×6.9in.(197.2mm×40.24mm×175mm)3800-8,2800-43800-8:combinedslots1and3,orcombinedslots5and72800-4:combinedslots1and3DPIU(full-height)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)3800-8,2800-4,2800-3E3800-8:slot3or72800-4:slot32800-3E:slots2PIU7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)3800-8,2800-4,2800-3E3800-8:slot1,3,5,or72800-4:slot1or32800-3E:slot2SPIU3.86in.×0.79in.×6.9in.(98.1mm×19.92mm×175mm)3800-8,2800-4,1800-2S,2800-3E,1800-2E3800-8:slot0,2,4,or62800-4:slot0or21800-2S:slot0or12800-3E:slot0or11800-2E:slot0or1TheDPIUisafast-speedinterfaceboard,andthePIUandSPIUarecommon-speedinterfaceboards.TheZXR102800-4andZXR103800-8supportthecombinationofdifferenttypesoflineinterfaceboards.TableofContentsRAC-SPIU-02CE1-75.................................................................................................9-2RAC-SPIU-02UE1-75.................................................................................................9-3RAC-SPIU-02CE1-120...............................................................................................9-5RAC-SPIU-02UE1-120...............................................................................................9-6RAC-SPIU-02HS........................................................................................................9-89-1SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionRAC-SPIU-04GE........................................................................................................9-9RAC-PIU-LTE...........................................................................................................9-11RAC-PIU-01DSLB....................................................................................................9-13RAC-PIU-04SHDSL.................................................................................................9-15RAC-PIU-04HS.......................................................................................................9-16RAC-PIU-04CE1-75.................................................................................................9-18RAC-PIU-04CE1-120...............................................................................................9-19RAC-PIU-04UE1-75.................................................................................................9-21RAC-PIU-04UE1-120...............................................................................................9-22RAC-PIU-16CE1......................................................................................................9-23RAC-PIU-16CE1-CES..............................................................................................9-25RAC-PIU-01P12-SFP...............................................................................................9-26RAC-PIU-02P3-SFP.................................................................................................9-28RAC-PIU-04P3-SFP.................................................................................................9-29RAC-PIU-02CP3-SFP..............................................................................................9-31RAC-PIU-04CP3-SFP..............................................................................................9-32RAC-PIU-04GE-SFP................................................................................................9-34RAC-PIU-08GE-SFP................................................................................................9-35RAC-PIU-05GE-4E1SFP..........................................................................................9-36RAC-PIU-09GE-8E1SFP..........................................................................................9-39RAC-PIU-08FE1GE-1SFP........................................................................................9-41RAC-DPIU-16GE-12SFP4E.....................................................................................9-43RAC-DPIU-01XGE-SFP+.........................................................................................9-459.1RAC-SPIU-02CE1-75OverviewRAC-SPIU-02CE1-75boardprovidesthefollowingfunctions:lProvidestwochannelized/unchannelizedE1(75ohm)interfaces.lRestoresthelineclockandprovidingittoanMPFUboardforreference.lSupportstheprocessingofvariousservices,suchasPPPandML-PPP.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-SPIU-02CE1-75board,seeFigure9-1.Figure9-1FrontPaneloftheRAC-SPIU-02CE1-75Board9-2SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsInterfacePropertyTheRAC-SPIU-02CE1-75boardprovidesmicrocoaxialinterfaces,anditonlysupports75ohmnon-balancedE1interfaces.Foradescriptionoftheinterfaceproperties,refertoTable9-2.Table9-2InterfacePropertiesoftheRAC-SPIU-02CE1-75BoardPropertyDescriptionConnectortypeMicrocoaxialOperationalmodeFullduplexAppliedstandardITU-TG.703,G.704SupportedlinkprotocolPPP ,ML-PPP ,HDLC,FRSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-SPIU-02CE1-75board,refertoT able9-3.Table9-3DescriptionoftheIndicatorsonthePaneloftheRAC-SPIU-02CE1-75BoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.LNK1/LNK2GreenTheindicatorislitwhenthelinkisoperatingproperly,andisnotlitwhenthelinkisidle.TechnicalParametersForthetechnicalparametersoftheRAC-SPIU-02CE1-75board,refertoT able9-4.Table9-4TechnicalParametersoftheRAC-SPIU-02CE1-75BoardParameterSpecicationSilkscreennameRAC-SPIU-02CE1-75Dimensions(W×H×D)3.86in.×0.79in.×6.9in.(98.1mm×19.92mm×175mm)Powerconsumption6WWeight0.53lb.(0.24kg)Rate2.048Mbps×29.2RAC-SPIU-02UE1-75OverviewRAC-SPIU-02UE1-75boardprovidesthefollowingfunctions:9-3SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionlProvidestwounchannelizedE1(75ohm)interfaces.lRestoresthelineclockandprovidingittoanMPFUboardforreference.lSupportstheprocessingofvariousservices,suchasPPPandML-PPP.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-SPIU-02UE1-75board,seeFigure9-2.Figure9-2FrontPaneloftheRAC-SPIU-02UE1-75BoardInterfacePropertyTheRAC-SPIU-02UE1-75boardprovidesmicrocoaxialinterfaces,anditonlysupports75ohmnon-balancedE1interfaces.Foradescriptionoftheinterfaceproperties,refertoTable9-5.Table9-5InterfacePropertiesoftheRAC-SPIU-02UE1-75BoardPropertyDescriptionConnectortypeMicrocoaxialOperationalmodeFullduplexAppliedstandardITU-TG.703,G.704SupportedlinkprotocolPPP ,ML-PPP ,HDLC,FRSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-SPIU-02UE1-75board,refertoT able9-6.Table9-6DescriptionoftheIndicatorsonthePaneloftheRAC-SPIU-02UE1-75BoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.LNK1/LNK2GreenTheindicatorislitwhenthelinkisoperatingproperly,andisnotlitwhenthelinkisidle.TechnicalParametersForthetechnicalparametersoftheRAC-SPIU-02UE1-75board,refertoT able9-7.9-4SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsTable9-7TechnicalParametersoftheRAC-SPIU-02UE1-75BoardParameterSpecicationSilkscreennameRAC-SPIU-02UE1-75Dimensions(W×H×D)3.86in.×0.79in.×6.9in.(98.1mm×19.92mm×175mm)Powerconsumption6WWeight0.53lb.(0.24kg)Rate2.048Mbps×29.3RAC-SPIU-02CE1-120OverviewRAC-SPIU-02CE1-120boardprovidesthefollowingfunctions:lProvidestwochannelized/unchannelizedE1(120ohm)interfaces.lRestoresthelineclockandprovidingittoanMPFUboardforreference.lSupportstheprocessingofvariousservices,suchasPPPandML-PPP.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.lSupportsthedelayedpower-onfunction.Whentherouterispoweredon,alltheboardsarestartedup,causingahighpressureonthepowersupply.Thedelayedpower-onfunctioncanreducetheelectriccurrentimpactcausedbytheboardsandprotectcomponentsfromdamageduetotheinstantaneoussurgecurrent.PanelForthepaneloftheRAC-SPIU-02CE1-120board,seeFigure9-3.Figure9-3FrontPaneloftheRAC-SPIU-02CE1-120BoardInterfacePropertyTheRAC-SPIU-02CE1-120boardprovidesRJ48interfaces,anditonlysupports120ohmE1interfaces.Foradescriptionoftheinterfaceproperties,refertoT able9-8.Table9-8InterfacePropertiesoftheRAC-SPIU-02CE1-120BoardPropertyDescriptionConnectortypeRJ489-5SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionPropertyDescriptionOperationalmodeFullduplexAppliedstandardITU-TG.703,G.704SupportedlinkprotocolPPP ,ML-PPP ,HDLC,FRSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-SPIU-02CE1-120board,refertoTable9-9.Table9-9DescriptionoftheIndicatorsonthePaneloftheRAC-SPIU-02CE1-120BoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.LNK1/LNK2GreenTheindicatorislitwhenthelinkisoperatingproperly,andisnotlitwhenthelinkisidle.TechnicalParametersForthetechnicalparametersoftheRAC-SPIU-02CE1-120board,refertoTable9-10.Table9-10TechnicalParametersoftheRAC-SPIU-02CE1-120BoardParameterSpecicationSilkscreennameRAC-SPIU-02CE1-120Dimensions(W×H×D)3.86in.×0.79in.×6.9in.(98.1mm×19.92mm×175mm)Powerconsumption6WWeight0.53lb.(0.24kg)Rate2.048Mbps×29.4RAC-SPIU-02UE1-120OverviewRAC-SPIU-02UE1-120boardprovidesthefollowingfunctions:lProvidestwounchannelizedE1(120ohm)interfaces.lRestoresthelineclockandprovidingittoanMPFUboardforreference.lSupportstheprocessingofvariousservices,suchasPPPandML-PPP.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.lSupportsthedelayedpower-onfunction.9-6SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsPanelForthepaneloftheRAC-SPIU-02UE1-120board,seeFigure9-4.Figure9-4FrontPaneloftheRAC-SPIU-02UE1-120BoardInterfacePropertyTheRAC-SPIU-02UE1-120boardprovidesRJ48interfaces,anditonlysupports120ohmE1interfaces.Foradescriptionoftheinterfaceproperties,refertoTable9-11.Table9-11InterfacePropertiesoftheRAC-SPIU-02UE1-120BoardPropertyDescriptionConnectortypeRJ48OperationalmodeFullduplexAppliedstandardITU-TG.703,G.704SupportedlinkprotocolPPP ,ML-PPP ,HDLC,FRSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-SPIU-02UE1-120board,refertoT able9-12.Table9-12DescriptionoftheIndicatorsonthePaneloftheRAC-SPIU-02UE1-120BoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.LNK1/LNK2GreenTheindicatorislitwhenthelinkisoperatingproperly,andisnotlitwhenthelinkisidle.TechnicalParametersForthetechnicalparametersoftheRAC-SPIU-02UE1-120board,refertoTable9-13.Table9-13TechnicalParametersoftheRAC-SPIU-02UE1-120BoardParameterSpecicationSilkscreennameRAC-SPIU-02UE1-120Dimensions(W×H×D)3.86in.×0.79in.×6.9in.(98.1mm×19.92mm×175mm)Powerconsumption6WWeight0.53lb.(0.24kg)9-7SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionParameterSpecicationRate2.048Mbps×29.5RAC-SPIU-02HSOverviewRAC-SPIU-02HSboardprovidesthefollowingfunctions:lProvides2-wireserialportssupportingasynchronousorsynchronousdatatransmissionmode.àForsynchronousdatatransmissionmode,theportscanbeconnectedtoDTEsorDCEs.ThecircuitsidesupportstheV.24,V.35orX.21interfaces.TheV.24interfacesupportsamaximumrateof115.2Kbps.TheV.35interfacesupportsamaximumrateof4.096Mbps.TheX.21interfacesupportsamaximumrateof48Kbps.àAsynchronousdatatransmissionmodesupportstheRS232interfacethatsupportsamaximumrateof115.2Kbps.lSupportstheprocessingofvariousservices,suchasPPPandHDLC.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-SPIU-02HSboard,seeFigure9-5.Figure9-5FrontPaneloftheRAC-SPIU-02HSBoardInterfacePropertyForadescriptionoftheinterfaceproperties,refertoT able9-14.Table9-14InterfacePropertiesoftheRAC-SPIU-02HSBoardPropertyDescriptionConnectortypeDB50OperationalmodeAsynchronousorsynchronousAppliedstandardV.24,V.35,X.21,orRS232SupportedlinkprotocolPPP,HDLC,andFR9-8SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsPropertyDescriptionSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-SPIU-02HSboard,refertoT able9-15.Table9-15DescriptionoftheIndicatorsonthePaneloftheRAC-SPIU-02HSBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.LNK1/LNK2GreenTheindicatorislitwhenthelinkisoperatingproperly,andisnotlitwhenthelinkisidle.TechnicalParametersForthetechnicalparametersoftheRAC-SPIU-02HSboard,refertoT able9-16.Table9-16TechnicalParametersoftheRAC-SPIU-02HSBoardParameterSpecicationSilkscreennameRAC-SPIU-02HSDimensions(W×H×D)3.86in.×0.79in.×6.9in.(98.1mm×19.92mm×175mm)Powerconsumption7WWeight0.46lb.(0.21kg)RateMultiplerates,upto4.096Mbps.9.6RAC-SPIU-04GEOverviewAnRAC-SPIU-04GEboardhasthefollowingfunctions:lProvidesfourlinesofelectricalinterfacesforgigabitEthernetinterfacecards.lSupportsself-adaptive10/100/1000BASE-T.lSupportshopswappingofboards.lSupportsboardtemperaturedetectionandboardIDread.PanelForthepanelofanRAC-SPIU-04GEboard,seeFigure9-6.9-9SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionFigure9-6FrontPanelofanRAC-SPIU-04GEBoardAttributesofInterfacesAnRAC-SPIU-04GEboardprovideselectricalinterfaces.Forattributesoftheseelectricalinterfaces,refertoTable9-17.Table9-17AttributesofInterfacesonanRAC-SPIU-04GEBoardDescriptionDescriptionInterfaceTypeRJ45WorkingModeFullduplex,andhalfduplexStandardIEEE802.3zGigabitEthernetstandardLinkprotocolEthernetframeNetwortprotocolIPIndicatorsForfunctionsofindicatorsonthepaneloftheRAC-SPIU-04GEboard,refertoT able9-18.Table9-18DescriptionofFunctionsoftheIndicatorsonthePaneloftheRAC-SPIU-04GEBoardIndicatorColorDescriptionElectricalinterfaceindicatorGreenandyellowFourgroupsoflinkstatus/datacommunicationindicatorsforGEelectricalinterfaces:lIfthelinkisproperlyconnected,theindicatorinthetoprightcorneroftheinterfaceturnssoldgreen.lIfdataistransmittedontheboard,theindicatorinthetoprightcorneroftheinterfaceashesyellow.lIfnodataistransmittedandnolinkisconnected,theindicatorturnsoff.TechnicalParametersFortechnicalparametersofanRAC-SPIU-04GEboard,refertoT able9-19.Table9-19TechnicalParametersofanRAC-SPIU-04GEBoardParameterDescriptionBoardnamesilkscreenRAC-SPIU-04GEDimension(width×height×depth)3.86in.×0.79in.×6.9in.(98.1mm×19.92mm×175mm)9-10SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsParameterDescriptionPowerconsumption7WWeight0.22lb.(0.1kg)Rate1GE×49.7RAC-PIU-LTEOverviewTheRAC-PIU-LTEisa3G/LTEinterfaceboardfortheZXR102800-4andZXR103800-8.Itsupports3G/LTEradionetworkaccess.ItcanoperateastheprimaryorsecondarylinkforenterprisestoaccesstheInternettotransferaudio,data,andvideoles.lSupportsTD-LTE,FDD-LTE,TD-SCDMA,WCDMA,andHSPA+.lSupportsthefrequencybandsofmultiplenetworks,including:àGSM/GPRSQuadBand(850,900,1800,and1900)àTD-SCDMAB34,andB39àWCDMAB1,B2,andB5àLTEB38,B39,B40,andB41àLTEFDDB1,B2,B3,B5,andB7àGPSL1lSupportsdifferentnetworkspeedsfordifferentnetworks.àForFDD-LTEandTD-LTE,theboardsupportsnetworkspeedsof100Mbpsand50Mbps.àForTD-SCDMA,theboardsupportsnetworkspeedsof2.8Mbpsand2.2Mbps.àForWCDMADC-HSPA+,theboardsupportsnetworkspeedsof42Mbpsand5.7Mbps.àForWCDMAHSDPA,theboardsupportsnetworkspeedsof21Mbpsand5.76Mbps.lSupportshot-swapping.PanelFigure9-7showsthepaneloftheRAC-PIU-LTEboard.Figure9-7RAC-PIU-LTEBoardPanel9-11SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionInterfaceAttributeTheRAC-PIU-LTEboardtransfersdatathroughtheradiosignalsontheSub-Miniature-A(SMA)interface(whipomnidirectionalantenna).Thepanelhasnootherexternalinterfaces.Note:TheSMAisacommonmodelofantennainterfaces.IndicatorsForadescriptionoftheindicatorsonthepaneloftheRAC-PIU-LTEboard,refertoT able9-20.Table9-20RAC-PIU-LTEBoardIndicatorDescriptionsIndicatorColorDescriptionRUNGreenOperationalstatusindicator.Itisonwhentheboardisoperatingproperly.ALMRedAlarmindicator.Itisoniftheboardhasanalarm.WWANGreenRadionetworkaccessindicator.Itasheswhentheboardtriestoaccessaradionetwork.Itisonwhentheboardaccessestheradionetworksuccessfully.Itisoffiftheboardfailstoaccesstheradionetwork.RSSIGreenSignalstrengthindicator.lRSSI≤-100dbm:Thereisnosignal.Theindicatorisoff.l-99dbm≤RSSI≤-90dbm:Thesignalisweak.Theindicatorashes.lRSSI≥-89dbm:Thesignalisstrong.Theindicatorison.3GGreen3Gsignalindicator.Itisonaftertheboardaccessesa3Gnetwork.LTEGreenLTEsignalindicator.ItisonaftertheboardaccessesanLTEnetwork.TechnicalSpecicationsForadescriptionofthetechnicalspecicationsoftheRAC-PIU-LTEboard,refertoT able9-21.9-12SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsTable9-21RAC-PIU-LTEBoardTechnicalSpecicationsParameterDescriptionsSilkscreennameRAC-PIU-LTEDimensions(Width×Height×Depth)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption7WWeight1.23lb.(0.56kg)9.8RAC-PIU-01DSLBOverviewRAC-PIU-01DSLBboardprovidesthefollowingfunctions:lProvidesoneDSLinterface,whichsupportstheVDSL2/ADSL2+mode.lProvidesoneDSL(B)interface,whichsupportstobeboundwiththeDSLinterface.Forsingle-interfaceaccess,theDSLinterfaceisused.Fordual-interfaceaccess,boththeDSLandDSL(B)interfacesareusedanditisnotallowedtousetheDSL(B)interfaceonly.lSupportstheDyingGaspfunction.Itisapower-downalarmfunction.Whentheinputvoltagecannotmeetthenormaloperationrequirement,theboardgeneratesanalarmwiththelastelectricenergy.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-01DSLBboard,seeFigure9-8.Figure9-8FrontPaneloftheRAC-PIU-01DSLBBoardInterfacePropertyForadescriptionoftheinterfaceproperties,refertoT able9-22.Table9-22InterfacePropertiesoftheRAC-PIU-01DSLBBoardPropertyDescriptionConnectortypeRJ-11interface,whichcanbeconnectedtoaDSLAMthroughacommontelephonecable9-13SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionPropertyDescriptionOperationalmodeVDSL2/ADSL2+modeAppliedstandardVDSL:lITU-TG.993.2(VDSL2)lITU-TG.993.5(G.vector)ADSL:lITU-TG.992.1(G.dmt),AnnexA,B,andClITU-TG.992.2(G.lite),AnnexAandClANSIT1.413lITU-TG.992.3(ADSL2),AnnexA,B,C,L,andMlITU-TG.992.5(ADSL2+),AnnexA,B,C,andMSupportedlinkprotocolATM,PTMSupportednetworkprotocolPPPoEoA,IPoEoAIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-01DSLBboard,refertoTable9-23.Table9-23DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-01DSLBBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedAlarmindicator,whichislitwhentheboardhasanalarm.LNK/ACTGreen,YellowLinkstatus/datatransmissionindicator:lIfthelinkisnormal,theindicatorislitingreen.lIfdataisbeingtransmitted,theindicatorashesinyellow.lIfthereisnodatabeingtransmittedornoconnection,theindicatorisnotlit.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-01DSLBboard,refertoT able9-24.Table9-24TechnicalParametersoftheRAC-PIU-01DSLBBoardParameterSpecicationSilkscreennameRAC-PIU-01DSLBDimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption16WWeight0.88lb.(0.4kg)9-14SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsParameterSpecicationRateInADSL2+fullratemode(ITU-T992.5):Thedownlinkratecanreach24Mbpsandtheuplinkratecanreach1Mbps.InVDSL2mode(ITU-T993.2):Thedownlinkratecanreach100Mbpsandtheuplinkratecanreach50Mbps.9.9RAC-PIU-04SHDSLOverviewRAC-PIU-04SHDSLboardprovidesthefollowingfunctions:lProvidesoneG.SHDSL(SHDSLgroup)interface,whichprovidesfourSHDSLelectricalinterfaces.SymmetricHighbitrateDigitalSubscriberLine(SHDSL)evolvesfromHDSLandcomplieswiththeITU-TG.991.2andG.994.2standards.Onlyonepairoftelephonelinesarerequiredfordatatransmission,whichreducestherequirementoncopperwireresources.SHDSLusestheTC-PAM16/32/64codingmode,whereagreaternumberrepresentsafastertransmissionspeed.Itcanbeusedforaudio,video,anddatatransmission.lSupportstheATMandEFMprotocolencapsulationmodes.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-04SHDSLboard,seeFigure9-9.Figure9-9FrontPaneloftheRAC-PIU-04SHDSLboardInterfacePropertiesForadescriptionoftheinterfaceproperties,refertoT able9-25.Table9-25InterfacePropertiesoftheRAC-PIU-04SHDSLBoardPropertyDescriptionConnectortypeRJ45interface,connectedtofourRJ11interfacesatthepeerendOperationalmodeFullduplexAppliedstandardITU-TG.991.29-15SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionPropertyDescriptionSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-04SHDSLboard,refertoT able9-26.Table9-26DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04SHDSLBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.LNK/ACTGreen,YellowLinkstatus/datatransmissionindicator:lIfthelinkisnormal,theindicatorislitingreen.lIfdataisbeingtransmitted,theindicatorashesinyellow.lIfthereisnodatabeingtransmittedornoconnection,theindicatorisnotlit.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-04SHDSLboard,refertoT able9-27.Table9-27TechnicalParametersoftheRAC-PIU-04SHDSLBoardParameterSpecicationSilkscreennameRAC-PIU-04SHDSLDimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption10WWeight1.19lb.(0.54kg)Rate5.696Mbit/s/pair9.10RAC-PIU-04HSOverviewRAC-PIU-04HSboardprovidesthefollowingfunctions:lProvides4-wireserialportssupportingasynchronousorsynchronousdatatransmissionmode.àForsynchronousdatatransmissionmode,theportscanbeconnectedtoDTEsorDCEs.ThecircuitsidesupportstheV.24,V.35,orX.21interfaces.TheV.24interfacesupportsamaximumrateof115.2Kbps.TheV.35interfacesupports9-16SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsamaximumrateof4.096Mbps.TheX.21interfacesupportsamaximumrateof48Kbps.àAsynchronousdatatransmissionmodesupportstheRS232interfacethatsupportsamaximumrateof115.2Kbps.lSupportstheprocessingofvariousservices,suchasPPPandHDLC.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-04HSboard,seeFigure9-10.Figure9-10FrontPaneloftheRAC-PIU-04HSBoardInterfacePropertyForadescriptionoftheinterfaceproperties,refertoT able9-28.Table9-28InterfacePropertiesoftheRAC-PIU-04HSBoardPropertyDescriptionConnectortypeDB50OperationalmodeAsynchronousorsynchronousAppliedstandardV.24,V.35,X.21orRS232SupportedlinkprotocolPPP,HDLCorFRSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-04HSboard,refertoTable9-29.Table9-29DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04HSBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.LNK1–LNK4GreenTheindicatorislitwhenthelinkisoperatingproperly,andisnotlitwhenthelinkisidle.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-04HSboard,refertoTable9-30.9-17SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionTable9-30TechnicalParametersoftheRAC-PIU-04HSBoardParameterSpecicationSilkscreennameRAC-PIU-04HSDimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption10WWeight1.19lb.(0.54kg)Rate1200bps–4.096Mbps×49.11RAC-PIU-04CE1-75OverviewRAC-PIU-04CE1-75boardprovidesthefollowingfunctions:lProvidesfourchannelized/unchannelizedE1(75ohm)interfaces.lRestoresthelineclockandprovidingittoanMPFUboardforreference.lSupportstheprocessingofvariousservices,suchasPPPandML-PPP.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-04CE1-75board,seeFigure9-11.Figure9-11FrontPaneloftheRAC-PIU-04CE1-75BoardInterfacePropertyTheRAC-PIU-04CE1-75boardprovidesmicrocoaxialinterfaces,anditonlysupports75ohmnon-balancedE1interfaces.Foradescriptionoftheinterfaceproperties,refertoTable9-31.Table9-31InterfacePropertiesoftheRAC-PIU-04CE1-75BoardPropertyDescriptionConnectortypeMicrocoaxialOperationalmodeFullduplexAppliedstandardITU-TG.703,G.704SupportedlinkprotocolPPP ,ML-PPP ,HDLC,FR9-18SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsPropertyDescriptionSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-04CE1-75board,refertoT able9-32.Table9-32DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04CE1-75BoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.LNK1–LNK4GreenTheindicatorislitwhenthelinkisoperatingproperly,andisnotlitwhenthelinkisidle.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-04CE1-75board,refertoT able9-33.Table9-33TechnicalParametersoftheRAC-PIU-04CE1-75BoardParameterSpecicationSilkscreennameRAC-PIU-04CE1-75Dimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption11WWeight1.19lb.(0.54kg)Rate2.048Mbps×49.12RAC-PIU-04CE1-120OverviewRAC-PIU-04CE1-120boardprovidesthefollowingfunctions:lProvidesfourchannelized/unchannelizedE1(120ohm)interfaces.lRestoresthelineclockandprovidingittoanMPFUboardforreference.lSupportstheprocessingofvariousservices,suchasPPPandML-PPP.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.lSupportsthedelayedpower-onfunction.PanelForthepaneloftheRAC-PIU-04CE1-120board,seeFigure9-12.9-19SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionFigure9-12FrontPaneloftheRAC-PIU-04CE1-120BoardInterfacePropertyTheRAC-PIU-04CE1-120boardprovidesRJ48interfaces,anditonlysupports120ohmE1interfaces.Foradescriptionoftheinterfaceproperties,refertoTable9-34.Table9-34InterfacePropertiesoftheRAC-PIU-04CE1-120BoardPropertyDescriptionConnectortypeRJ48OperationalmodeFullduplexAppliedstandardITU-TG.703,G.704SupportedlinkprotocolPPP ,ML-PPP ,HDLC,FRSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-04CE1-120board,refertoTable9-35.Table9-35DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04CE1-120BoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.LNK1–LNK4GreenTheindicatorislitwhenthelinkisoperatingproperly,andisnotlitwhenthelinkisidle.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-04CE1-120board,refertoT able9-36.Table9-36TechnicalParametersoftheRAC-PIU-04CE1-120BoardParameterSpecicationSilkscreennameRAC-PIU-04CE1-120Dimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption11WWeight1.19lb.(0.54kg)Rate2.048Mbps×49-20SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoards9.13RAC-PIU-04UE1-75OverviewRAC-PIU-04UE1-75boardprovidesthefollowingfunctions:lProvidesfourunchannelizedE1(75ohm)interfaces.lRestoresthelineclockandprovidingittoanMPFUboardforreference.lSupportstheprocessingofvariousservices,suchasPPPandML-PPP.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-04UE1-75board,seeFigure9-13.Figure9-13FrontPaneloftheRAC-PIU-04UE1-75BoardInterfacePropertyTheRAC-PIU-04UE1-75boardprovidesmicrocoaxialinterfaces,anditonlysupports75ohmnon-balancedE1interfaces.Foradescriptionoftheinterfaceproperties,refertoTable9-37.Table9-37InterfacePropertiesoftheRAC-PIU-04UE1-75BoardPropertyDescriptionConnectortypeMicrocoaxialOperationalmodeFullduplexAppliedstandardITU-TG.703,G.704SupportedlinkprotocolPPP ,ML-PPP ,HDLC,FRSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-04UE1-75board,refertoT able9-38.Table9-38DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04UE1-75BoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.9-21SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionIndicatorColorDescriptionLNK1–LNK4GreenTheindicatorislitwhenthelinkisoperatingproperly,andisnotlitwhenthelinkisidle.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-04UE1-75board,refertoT able9-39.Table9-39TechnicalParametersoftheRAC-PIU-04UE1-75BoardParameterSpecicationSilkscreennameRAC-PIU-04UE1-75Dimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption11WWeight1.19lb.(0.54kg)Rate2.048Mbps×49.14RAC-PIU-04UE1-120OverviewRAC-PIU-04UE1-120boardprovidesthefollowingfunctions:lProvidesfourunchannelizedE1(120ohm)interfaces.lRestoresthelineclockandprovidingittoanMPFUboardforreference.lSupportstheprocessingofvariousservices,suchasPPPandML-PPP.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.lSupportsthedelayedpower-onfunction.PanelForthepaneloftheRAC-PIU-04UE1-120board,seeFigure9-14.Figure9-14FrontPaneloftheRAC-PIU-04UE1-120BoardInterfacePropertyTheRAC-PIU-04UE1-120boardprovidesRJ48interfaces,anditonlysupports120ohmE1interfaces.Foradescriptionoftheinterfaceproperties,refertoTable9-40.9-22SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsTable9-40InterfacePropertiesoftheRAC-PIU-04UE1-120BoardPropertyDescriptionConnectortypeRJ48OperationalmodeFullduplexAppliedstandardITU-TG.703,G.704SupportedlinkprotocolPPP ,ML-PPP ,HDLC,FRSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-04UE1-120board,refertoTable9-41.Table9-41DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04UE1-120BoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.LNK1–LNK4GreenTheindicatorislitwhenthelinkisoperatingproperly,andisnotlitwhenthelinkisidle.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-04UE1-120board,refertoT able9-42.Table9-42TechnicalParametersoftheRAC-PIU-04UE1-120BoardParameterSpecicationSilkscreennameRAC-PIU-04UE1-120Dimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption11WWeight1.19lb.(0.54kg)Rate2.048Mbps×49.15RAC-PIU-16CE1OverviewRAC-PIU-16CE1boardprovidesthefollowingfunctions:lProvides16channelized/unchannelizedE1interfaces.lSupportstheprocessingofvariousservices,suchasPPPandML-PPP.lSupportshotswapping.9-23SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionlSupportsboardinformationqueryandtemperaturemonitoring.lSupportsthe75Ωor120Ωconguration.TheboardprovidesjumpersX6,X9,andX10toconguretheinterfaceresistanceto75Ωor120Ω.Bydefault,theinterfaceresistanceis75Ω.Fortheinterfaceresistanceconguration,refertothefollowingtable.Jumper75Ω120ΩX62-3:ON1-2:ONX9andX10ONOFFCaution!Thejumpercongurationcanbeperformedbyprofessionalsonly.PanelForthepaneloftheRAC-PIU-16CE1board,seeFigure9-15.Figure9-15FrontPaneloftheRAC-PIU-16CE1BoardInterfacePropertiesFortheinterfacepropertiesoftheRAC-PIU-16CE1board,refertoTable9-43.Table9-43InterfacePropertiesoftheRAC-PIU-16CE1BoardPropertyDescriptionConnectortypeDB50OperationalmodeFullduplexAppliedstandardITU-TG.703,G.704SupportedlinkprotocolPPP ,ML-PPP ,HDLC,FRSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-16CE1board,refertoT able9-44.9-24SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsTable9-44DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-16CE1BoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-16CE1board,refertoT able9-45.Table9-45TechnicalParametersoftheRAC-PIU-16CE1BoardParameterSpecicationSilkscreennameRAC-PIU-16CE1Dimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption16WWeight1.19lb.(0.54kg)Rate2.048Mbps×169.16RAC-PIU-16CE1-CESOverviewRAC-PIU-16CE1-CESboardprovidesthefollowingfunctions:lProvides16channelized/unchannelizedE1interfaces.lSupportstheprocessingofvariousservices,suchasTDM,PPPandML-PPP.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.lSupportsthe75Ωor120Ωconguration.PanelForthepaneloftheRAC-PIU-16CE1-CESboard,seeFigure9-16.Figure9-16FrontPaneloftheRAC-PIU-16CE1-CESBoardInterfacePropertiesFortheinterfacepropertiesoftheRAC-PIU-16CE1-CESboard,refertoT able9-46.9-25SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionTable9-46InterfacePropertiesoftheRAC-PIU-16CE1-CESBoardPropertyDescriptionConnectortypeDB50OperationalmodeFullduplexAppliedstandardITU-TG.703,G.704SupportedlinkprotocolTDMIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-16CE1-CESboard,refertoTable9-47.Table9-47DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-16CE1-CESBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-16CE1-CESboard,refertoTable9-48.Table9-48TechnicalParametersoftheRAC-PIU-16CE1-CESBoardParameterSpecicationSilkscreennameRAC-PIU-16CE1-CESDimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption16WWeight1.19lb.(0.54kg)Rate2.048Mbps×169.17RAC-PIU-01P12-SFPOverviewRAC-PIU-01P12-SFPboardprovidesthefollowingfunctions:lSupports1-wireOC-12/STM-4POSapplications.lSupportstheprocessingofvariousservices,suchasPPPandHDLC.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-01P12-SFPboard,seeFigure9-17.9-26SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsFigure9-17FrontPaneloftheRAC-PIU-01P12-SFPBoardInterfacePropertyTheRAC-PIU-01P12-SFPboardusesSFPopticalmodules.Foradescriptionoftheinterfaceproperties,refertoT able9-49.Table9-49InterfacePropertiesoftheRAC-PIU-01P12-SFPBoardPropertyDescriptionConnectortypeLC-typeSFPopticalmoduleinterfaceOperationalmodeFullduplexAppliedstandardSONETGR-253-CORE/ITU-TG.707SupportedlinkprotocolPPP ,HDLC,FR,POSGROUPSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-01P12-SFPboard,refertoTable9-50.Table9-50DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-01P12-SFPBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.LNK/ACTGreen/YellowLinkstatus/datatransmissionindicator:lIfthelinkisnormal,theindicatorislitingreen.lIfdataisbeingtransmitted,theindicatorashesinyellow.lIfthereisnodatabeingtransmittedornoconnection,theindicatorisnotlit.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-01P12-SFPboard,refertoT able9-51.Table9-51TechnicalParametersoftheRAC-PIU-01P12-SFPBoardParameterSpecicationSilkscreennameRAC-PIU-01P12-SFPDimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption16W9-27SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionParameterSpecicationWeight1.19lb.(0.54kg)Rate622.08Mbps9.18RAC-PIU-02P3-SFPOverviewRAC-PIU-02P3-SFPboardprovidesthefollowingfunctions:lSupports2-wireOC-3/STM-1POSapplications.lSupportstheprocessingofvariousservices,suchasPPPandHDLC.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-02P3-SFPboard,seeFigure9-18.Figure9-18FrontPaneloftheRAC-PIU-02P3-SFPBoardInterfacePropertyTheRAC-PIU-02P3-SFPboardusesSFPopticalmodules.Foradescriptionoftheinterfaceproperties,refertoT able9-52.Table9-52InterfacePropertiesoftheRAC-PIU-02P3-SFPBoardPropertyDescriptionConnectortypeLC-typeSFPopticalmoduleinterfaceOperationalmodeFullduplexAppliedstandardSONETGR-253-CORE/ITU-TG.707SupportedlinkprotocolPPP ,HDLC,FR,POSGROUPSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-02P3-SFPboard,refertoT able9-53.9-28SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsTable9-53DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-02P3-SFPBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.LNK/ACTGreen/YellowLinkstatus/datatransmissionindicator:lIfthelinkisnormal,theindicatorislitingreen.lIfdataisbeingtransmitted,theindicatorashesinyellow.lIfthereisnodatabeingtransmittedornoconnection,theindicatorisnotlit.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-02P3-SFPboard,refertoT able9-54.Table9-54TechnicalParametersoftheRAC-PIU-02P3-SFPBoardParameterSpecicationSilkscreennameRAC-PIU-02P3-SFPDimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption16.5WWeight1.19lb.(0.54kg)Rate155.52Mbps×29.19RAC-PIU-04P3-SFPOverviewRAC-PIU-04P3-SFPboardprovidesthefollowingfunctions:lProvidesfourOC-3/STM-1interfacestoimplementPOSapplications.lSupportstheprocessingofvariousservices,suchasPPPandHDLC.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-04P3-SFPboard,seeFigure9-19.Figure9-19FrontPaneloftheRAC-PIU-04P3-SFPBoard9-29SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionInterfacePropertiesTheRAC-PIU-04P3-SFPboardusesSFPopticalmodules.Foradescriptionoftheinterfaceproperties,refertoT able9-55.Table9-55InterfacePropertiesoftheRAC-PIU-04P3-SFPBoardPropertyDescriptionConnectortypeLC-typeSFPopticalmoduleinterfaceOperationalmodeFullduplexAppliedstandardSONETGR-253-CORE/ITU-TG.707SupportedlinkprotocolPPP ,HDLC,FR,POSGROUPSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-04P3-SFPboard,refertoT able9-56.Table9-56DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04P3-SFPBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.LNK/ACTGreen/YellowLinkstatus/datatransmissionindicator:lIfthelinkisnormal,theindicatorislitingreen.lIfdataisbeingtransmitted,theindicatorashesinyellow.lIfthereisnodatabeingtransmittedornoconnection,theindicatorisnotlit.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-04P3-SFPboard,refertoT able9-57.Table9-57TechnicalParametersoftheRAC-PIU-04P3-SFPBoardParameterSpecicationSilkscreennameRAC-PIU-04P3-SFPDimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption18WWeight1.19lb.(0.54kg)Rate155.52Mbps×49-30SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoards9.20RAC-PIU-02CP3-SFPOverviewRAC-PIU-02CP3-SFPboardprovidesthefollowingfunctions:lSupports2-wirechannelizedOC-3/STM-1POSapplications.lRestorestheopticalchanneldataclockandprovidingittoanMPFUboardforrefer-ence.lSupportstheprocessingofvariousservices,suchasPPPandHDLC.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-02CP3-SFPboard,seeFigure9-20.Figure9-20FrontPaneloftheRAC-PIU-02CP3-SFPBoardInterfacePropertyTheRAC-PIU-02CP3-SFPboardusesSFPopticalmodules.Foradescriptionoftheinterfaceproperties,refertoT able9-58.Table9-58InterfacePropertiesoftheRAC-PIU-02CP3-SFPBoardPropertyDescriptionConnectortypeLC-typeSFPopticalmoduleinterfaceOperationalmodeFullduplexAppliedstandardSONETGR-253-CORE/ITU-TG.707SupportedlinkprotocolPPP ,HDLC,FR,MPPPSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-02CP3-SFPboard,refertoTable9-59.Table9-59DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-02CP3-SFPBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.9-31SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionIndicatorColorDescriptionLNK/ACTGreen/YellowLinkstatus/datatransmissionindicator:lIfthelinkisnormal,theindicatorislitingreen.lIfdataisbeingtransmitted,theindicatorashesinyellow.lIfthereisnodatabeingtransmittedornoconnection,theindicatorisnotlit.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-02CP3-SFPboard,refertoT able9-60.Table9-60TechnicalParametersoftheRAC-PIU-02CP3-SFPBoardParameterSpecicationSilkscreennameRAC-PIU-02CP3-SFPDimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption16.5WWeight1.19lb.(0.54kg)Rate155.52Mbps×29.21RAC-PIU-04CP3-SFPOverviewRAC-PIU-04CP3-SFPboardprovidesthefollowingfunctions:lProvidesfourchannelizedOC3/STM-1interfacestoimplementPacketOverSONET/SDHapplications.lRestorestheopticalchanneldataclockandprovidesittoanMPFUboardforreference.lSupportstheprocessingofvariousservices,suchasPPPandHDLC.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-04CP3-SFPboard,seeFigure9-21.Figure9-21FrontPaneloftheRAC-PIU-04CP3-SFPBoard9-32SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsInterfacePropertiesTheRAC-PIU-04CP3-SFPboardusesSFPopticalmodules.Foradescriptionoftheinterfaceproperties,refertoT able9-61.Table9-61InterfacePropertiesoftheRAC-PIU-04CP3-SFPBoardPropertyDescriptionConnectortypeLC-typeSFPopticalmoduleinterfaceOperationalmodeFullduplexAppliedstandardSONETGR-253-CORE/ITU-TG.707SupportedlinkprotocolPPP ,HDLC,FR,MPPPSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-04CP3-SFPboard,refertoTable9-62.Table9-62DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04CP3-SFPBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.LNK/ACTGreen/YellowLinkstatus/datatransmissionindicator:lIfthelinkisnormal,theindicatorislitingreen.lIfdataisbeingtransmitted,theindicatorashesinyellow.lIfthereisnodatabeingtransmittedornoconnection,theindicatorisnotlit.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-04CP3-SFPboard,refertoT able9-63.Table9-63TechnicalParametersoftheRAC-PIU-04CP3-SFPBoardParameterSpecicationSilkscreennameRAC-PIU-04CP3-SFPDimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption18WWeight1.19lb.(0.54kg)Rate155.52Mbps×49-33SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescription9.22RAC-PIU-04GE-SFPOverviewRAC-PIU-04GE-SFPboardprovidesthefollowingfunctions:lProvidesfourGEopticalinterfaceswhichsupport1000BASE-X.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-04GE-SFPboard,seeFigure9-22.Figure9-22FrontPaneloftheRAC-PIU-04GE-SFPBoardInterfacePropertiesTheRAC-PIU-04GE-SFPboardusesSFPopticalmodules.Foradescriptionoftheinterfaceproperties,refertoT able9-64.Table9-64InterfacePropertiesoftheRAC-PIU-04GE-SFPBoardPropertyDescriptionConnectortypeLC-typeSFPopticalmoduleinterfaceOperationalmodeFullduplexAppliedstandardIEEE802.3zGigabitEthernetstandardSupportedlinkprotocolEthernetFrameSupportednetworkprotocolEthernetIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-04GE-SFPboard,refertoT able9-65.Table9-65DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04GE-SFPBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.9-34SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsIndicatorColorDescriptionLNK/ACTGreen/YellowLinkstatus/datatransmissionindicator:lIfthelinkisnormal,theindicatorislitingreen.lIfdataisbeingtransmitted,theindicatorashesinyellow.lIfthereisnodatabeingtransmittedornoconnection,theindicatorisnotlit.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-04GE-SFPboard,refertoT able9-66.Table9-66TechnicalParametersoftheRAC-PIU-04GE-SFPBoardParameterSpecicationSilkscreennameRAC-PIU-04GE-SFPDimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption13WWeight1.19lb.(0.54kg)Rate1GE×49.23RAC-PIU-08GE-SFPOverviewRAC-PIU-08GE-SFPboardprovidesthefollowingfunctions:lProvideseightGEopticalinterfaceswhichsupport1000BASE-X.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-08GE-SFPboard,seeFigure9-23.Figure9-23FrontPaneloftheRAC-PIU-08GE-SFPBoardInterfacePropertiesTheRAC-PIU-08GE-SFPboardusesSFPopticalmodules.Foradescriptionoftheinterfaceproperties,refertoT able9-67.9-35SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionTable9-67InterfacePropertiesoftheRAC-PIU-08GE-SFPBoardPropertyDescriptionConnectortypeLC-typeSFPopticalmoduleinterfaceOperationalmodeFullduplexAppliedstandardIEEE802.3zGigabitEthernetstandardSupportedlinkprotocolEthernetFrameSupportednetworkprotocolEthernetIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-08GE-SFPboard,refertoT able9-68.Table9-68DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-08GE-SFPBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.LNKGreenLinkstatus/datatransmissionindicator:lIfthelinkisnormal,theindicatorislitingreen.lIfdataisbeingtransmitted,theindicatorashesinyellow.lIfthereisnodatabeingtransmittedornoconnection,theindicatorisnotlit.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-08GE-SFPboard,refertoT able9-69.Table9-69TechnicalParametersoftheRAC-PIU-08GE-SFPBoardParameterSpecicationSilkscreennameRAC-PIU-08GE-SFPDimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption15WWeight1.19lb.(0.54kg)Rate1GE×89.24RAC-PIU-05GE-4E1SFPOverviewRAC-PIU-05GE-4E1SFPboardprovidesthefollowingfunctions:9-36SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardslProvidesfourGEelectricalinterfacesandoneGEopticalinterface.lTheGEelectricalinterfacessupport10BASE-T/100BASE-TX/1000BASE-TXandtheGEopticalinterfacesupports1000BASE-X.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-05GE-4E1SFPboard,seeFigure9-24.Figure9-24FrontPaneloftheRAC-PIU-05GE-4E1SFPBoardInterfacePropertiesTheRAC-PIU-05GE-4E1SFPboardprovideselectricalandopticalinterfaces(GE1–GE5),whicharenotdistinguishedbysilkscreenname.Theycanbedistinguishedbytheinterfaceoverviewandindicators.ForadescriptionoftheGEelectricalinterfacepropertiesoftheRAC-PIU-05GE-4E1SFPboard,refertoTable9-70.Table9-70GEElectricalInterfacePropertiesoftheRAC-PIU-05GE-4E1SFPBoardPropertyDescriptionConnectortypeRJ-45OperationalmodeFullduplex,HalfduplexAppliedstandardIEEE802.3zGigabitEthernetstandardSupportedframeformatEthernetframeSupportednetworkprotocolIPTheRAC-PIU-05GE-4E1SFPboardusesSFPopticalmodules.Foradescriptionoftheopticalinterfaceproperties,refertoTable9-71.Table9-71OpticalInterfacePropertiesoftheRAC-PIU-05GE-4E1SFPBoardPropertyDescriptionConnectortypeLC-typeSFPopticalmoduleinterfaceOperationalmodeFullduplexAppliedstandardIEEE802.3zGigabitEthernetstandardSupportedframeformatEthernetframe9-37SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionPropertyDescriptionSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-05GE-4E1SFPPboard,refertoTable9-72.Table9-72DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-05GE-4E1SFPBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.ElectricalportindicatorGreen/YellowLinkstatus/datatransmissionindicatorsforfourGEelectricalinterfaces:lIfthelinkisnormal,therightgreenindicatorislit.lIfdataisbeingtransmitted,theleftyellowindicatorashes.lIfthereisnodatabeingtransmittedornoconnection,theindicatorsarenotlit.LNK/ACTGreen/YellowLinkstatus/datatransmissionindicatorsfortheGEopticalinterface:lIfthelinkisnormal,theindicatorislitingreen.lIfdataisbeingtransmitted,theindicatorashesinyellow.lIfthereisnodatabeingtransmittedornoconnection,theindicatorisnotlit.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-05GE-4E1SFPboard,refertoT able9-73.Table9-73TechnicalParametersoftheRAC-PIU-05GE-4E1SFPBoardParameterSpecicationSilkscreennameRAC-PIU-05GE-4E1SFPDimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption11WWeight0.88lb.(0.4kg)Rate1GE×59-38SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoards9.25RAC-PIU-09GE-8E1SFPOverviewRAC-PIU-09GE-8E1SFPboardprovidesthefollowingfunctions:lProvideseightGEelectricalinterfacesandoneGEopticalinterface.lTheGEelectricalinterfacessupport10BASE-T/100BASE-TX/1000BASE-TXandtheGEopticalinterfacesupports1000BASE-X.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-09GE-8E1SFPboard,seeFigure9-25.Figure9-25FrontPaneloftheRAC-PIU-09GE-8E1SFPBoardInterfacePropertiesTheRAC-PIU-09GE-8E1SFPboardprovideselectricalandopticalinterfaces(GE1–GE9),whicharenotdistinguishedbysilkscreenname.Theycanbedistinguishedbytheinterfaceoverviewandindicators.ForadescriptionoftheGEelectricalinterfacepropertiesoftheRAC-PIU-09GE-8E1SFPboard,refertoTable9-74.Table9-74GEElectricalInterfacePropertiesoftheRAC-PIU-09GE-8E1SFPBoardPropertyDescriptionConnectortypeRJ45OperationalmodeFullduplex,HalfduplexAppliedstandardIEEE802.3zGigabitEthernetstandardSupportedframeformatEthernetframeSupportednetworkprotocolIPTheRAC-PIU-09GE-8E1SFPboardusesSFPopticalmodules.Foradescriptionoftheopticalinterfaceproperties,refertoTable9-75.Table9-75OpticalInterfacePropertiesoftheRAC-PIU-09GE-8E1SFPBoardPropertyDescriptionConnectortypeLC-typeSFPopticalmoduleinterface9-39SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionPropertyDescriptionOperationalmodeFullduplexAppliedstandardIEEE802.3zGigabitEthernetstandardSupportedframeformatEthernetframeSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-09GE-8E1SFPboard,refertoT able9-76.Table9-76DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-09GE-8E1SFPBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.ElectricalportindicatorGreen/YellowLinkstatus/datatransmissionindicatorsforfourGEelectricalinterfaces:lIfthelinkisnormal,therightgreenindicatorislit.lIfdataisbeingtransmitted,theleftyellowindicatorashes.lIfthereisnodatabeingtransmittedornoconnection,theindicatorsarenotlit.LNK/ACTGreen/YellowLinkstatus/datatransmissionindicatorsfortheGEopticalinterface:lIfthelinkisnormal,theindicatorislitingreen.lIfdataisbeingtransmitted,theindicatorashesinyellow.lIfthereisnodatabeingtransmittedornoconnection,theindicatorisnotlit.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-09GE-8E1SFPboard,refertoT able9-77.Table9-77TechnicalParametersoftheRAC-PIU-09GE-8E1SFPBoardParameterSpecicationSilkscreennameRAC-PIU-09GE-8E1SFPDimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption12WWeight1.19lb.(0.54kg)Rate1GE×99-40SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoards9.26RAC-PIU-08FE1GE-1SFPOverviewRAC-PIU-08FE1GE-1SFPboardprovidesthefollowingfunctions:lProvideseightFEelectricalinterfacesandoneGEopticalinterface.lTheFEelectricalinterfacessupport100BASE-TXandtheGEopticalinterfacesup-ports1000BASE-X.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-PIU-08FE1GE-1SFPboard,seeFigure9-26.Figure9-26FrontPaneloftheRAC-PIU-08FE1GE-1SFPBoardInterfacePropertiesTheRAC-PIU-08FE1GE-1SFPboardprovideselectricalandopticalinterfaces(FE1–FE8,GE1),whicharedistinguishedbysilkscreenname.Theycanbealsodistinguishedbytheinterfaceoverviewandindicators.ForadescriptionoftheFEelectricalinterfacepropertiesoftheRAC-PIU-08FE1GE-1SFPboard,refertoTable9-78.Table9-78GEElectricalInterfacePropertiesoftheRAC-PIU-08FE1GE-1SFPBoardPropertyDescriptionConnectortypeRJ45OperationalmodeFullduplex,HalfduplexAppliedstandardIEEE802.3uFastEthernetstandardSupportedframeformatEthernetframeSupportednetworkprotocolIPTheRAC-PIU-08FE1GE-1SFPboardusesSFPopticalmodules.Foradescriptionoftheopticalinterfaceproperties,refertoTable9-79.Table9-79OpticalInterfacePropertiesoftheRAC-PIU-08FE1GE-1SFPBoardPropertyDescriptionConnectortypeLC-typeSFPopticalmoduleinterface9-41SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionPropertyDescriptionOperationalmodeFullduplexAppliedstandardIEEE802.3zGigabitEthernetstandardSupportedframeformatEthernetframeSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-PIU-08FE1GE-1SFPboard,refertoT able9-80.Table9-80DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-08FE1GE-1SFPBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.ElectricalportindicatorGreen/YellowLinkstatus/datatransmissionindicatorsforfourGEelectricalinterfaces:lIfthelinkisnormal,therightgreenindicatorislit.lIfdataisbeingtransmitted,theleftyellowindicatorashes.lIfthereisnodatabeingtransmittedornoconnection,theindicatorsarenotlit.LNK/ACTGreen/YellowLinkstatus/datatransmissionindicatorsfortheGEopticalinterface:lIfthelinkisnormal,theindicatorislitingreen.lIfdataisbeingtransmitted,theindicatorashesinyellow.lIfthereisnodatabeingtransmittedornoconnection,theindicatorisnotlit.TechnicalParametersForthetechnicalparametersoftheRAC-PIU-08FE1GE-1SFPboard,refertoTable9-81.Table9-81TechnicalParametersoftheRAC-PIU-08FE1GE-1SFPBoardParameterSpecicationSilkscreennameRAC-PIU-08FE1GE-1SFPDimensions(W×H×D)7.76in.×0.79in.×6.9in.(197.2mm×19.92mm×175mm)Powerconsumption11WWeight1.19lb.(0.54kg)Rate1GE×1,1FE×89-42SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoards9.27RAC-DPIU-16GE-12SFP4EOverviewRAC-DPIU-16GE-12SFP4Eboardprovidesthefollowingfunctions:lProvidesfourGEelectricalinterfacesandtwelveGEopticalinterface.lTheGEelectricalinterfacessupport10BASE-T/100BASE-TX/1000BASE-TandtheGEopticalinterfacessupport1000BASE-X/100BASE-FX.lSupportshotswapping.lSupportsboardinformationqueryandtemperaturemonitoring.PanelForthepaneloftheRAC-DPIU-16GE-12SFP4Eboard,seeFigure9-27.Figure9-27FrontPaneloftheRAC-DPIU-16GE-12SFP4EBoardInterfacePropertiesTheRAC-DPIU-16GE-12SFP4Eboardprovideselectricalandopticalinterfaces(GE1–GE16),whicharenotdistinguishedbysilkscreenname.Theycanbedistinguishedbytheinterfaceoverviewandindicators.ForadescriptionoftheGEelectricalinterfacepropertiesoftheRAC-DPIU-16GE-12SFP4Eboard,refertoTable9-82.Table9-82GEElectricalInterfacePropertiesoftheRAC-DPIU-16GE-12SFP4EBoardPropertyDescriptionConnectortypeRJ45OperationalmodeFullduplex,HalfduplexAppliedstandardIEEE802.3zGigabitEthernetstandardSupportedframeformatEthernetframeSupportednetworkprotocolIPTheRAC-DPIU-16GE-12SFP4EboardusesSFPopticalmodules.Foradescriptionoftheopticalinterfaceproperties,refertoTable9-83.9-43SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionTable9-83OpticalInterfacePropertiesoftheRAC-DPIU-16GE-12SFP4EBoardPropertyDescriptionConnectortypeLC-typeSFPopticalmoduleinterfaceOperationalmodeFullduplexAppliedstandardIEEE802.3zGigabitEthernetstandardSupportedframeformatEthernetframeSupportednetworkprotocolIPIndicatorsForadescriptionoftheindicatorsoftheRAC-DPIU-16GE-12SFP4Eboard,refertoTable9-84.Table9-84DescriptionoftheIndicatorsonthePaneloftheRAC-DPIU-16GE-12SFP4EBoardIndicatorColorDescriptionRUNGreenTheindicatorislitwhentheboardisoperatingproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.ElectricalportindicatorGreen/YellowLinkstatus/datatransmissionindicatorsforfourGEelectricalinterfaces:lIfthelinkisnormal,therightgreenindicatorislit.lIfdataisbeingtransmitted,theleftyellowindicatorashes.lIfthereisnodatabeingtransmittedornoconnection,theindicatorsarenotlit.LNK/ACTGreen/YellowLinkstatus/datatransmissionindicatorsfor12GEopticalinterfaces:lIfthelinkisnormal,theindicatorislitingreen.lIfdataisbeingtransmitted,theindicatorashesinyellow.lIfthereisnodatabeingtransmittedornoconnection,theindicatorisnotlit.TechnicalParametersForthetechnicalparametersoftheRAC-DPIU-16GE-12SFP4Eboard,refertoTable9-85.Table9-85TechnicalParametersoftheRAC-DPIU-16GE-12SFP4EBoardParameterSpecicationSilkscreennameRAC-DPIU-16GE-12SFP4EDimensions(W×H×D)7.76in.×1.58in.×6.9in.(197.2mm×40.24mm×175mm)Powerconsumption36WWeight0.6kg9-44SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter9LineInterfaceBoardsParameterSpecicationRate1GE×169.28RAC-DPIU-01XGE-SFP+OverviewThesilkscreennameofthe1-portXGEinterfaceboardisRAC-DPIU-01XGE-SFP+,whichsupports10GEapplications.Itprovidesthefollowingfunctions:lProvidesone10GELAN/WANSFP+opticalinterface,whichsupports10GLAN/10GWAN.lSupportspowerramponcontrolandhotswappinglSupportstemperaturemeasurementandboardIDreading.PanelForthepaneloftheRAC-DPIU-01XGE-SFP+board,seeFigure9-28.Figure9-28FrontPaneloftheRAC-DPIU-01XGE-SFP+BoardInterfacePropertyTheRAC-DPIU-01XGE-SFP+boardusesSFP+opticalmodules.Foradescriptionoftheinterfaceproperties,refertoT able9-86.Table9-86InterfacePropertiesoftheRAC-DPIU-01XGE-SFP+BoardPropertyDescriptionConnectortypeLCOpticalinterfacepropertyDeterminedbytheattributesoftheselectedSFP+opticalmoduleOperationalmodeFullduplexAppliedstandardIEEE802.3aeSupportedlinkprotocolEthernetframe/SONET/SDHSupportednetworkprotocolIP9-45SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionIndicatorsOnthepaneloftheRAC-DPIU-01XGE-SFP+board,therearetwoboardoperationindicators(RUNandALM)andoneportoperationindicators(LNK/ACT ,green/yellow).Foradescriptionoftheindicators,refertoT able9-87.Table9-87DescriptionoftheIndicatorsonthePaneloftheRAC-DPIU-01XGE-SFP+BoardIndicatorColorDescriptionRUNGreenTheindicatorashesoncepersecondiftheboardoperatesproperly.ALMRedTheindicatorislitiftheboardproducesanalarm.LNK/ACTGreen/YellowOpticalportoperationindicator.Thegreenindicatorislitiftheportisinlinkupstatus,andtheyellowindicatorashesifthereistrafc.TechnicalParametersForthetechnicalparametersoftheRAC-DPIU-01XGE-SFP+board,refertoT able9-88.Table9-88TechnicalParametersoftheRAC-DPIU-01XGE-SFP+BoardParameterSpecicationSilkscreennameRAC-DPIU-01XGE-SFP+Dimensions(H×W×D)0.78in.×7.77in.×6.9in(19.92mm×197.2mm×175mm)Powerconsumption16WWeight0.68kgRate10G×19-46SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter10CablesForcablescommonlyusedbytheZXR10ZSRV2router,refertoT able10-1.Table10-1CommonCablesoftheZXR10ZSRV2RouterClassicationCableTypeFunctionDCpowercableUsedwhenDCpowerissuppliedtoadevice.ACpowercableUsedwhenACpowerissuppliedtoadevice.PowercablesandgroundingcablesGroundingcableConnectsacabinet,chassis,orcabinetdoortothegroundtoguaranteesafepowersupply.AUXcableConnectstheAUXportofadevicetoaModemfortransmittingdevicecongurationdata.ConsolecableConnectstheConsoleportofadevicetotheserialportofthecontrolconsolefortransmittingdevicecongurationdata.EthernetcableUsedforEthernetcommunicationbetweendevicesorbetweenadeviceandaterminal.OpticalberUsedforhigh-speedcommunicationbetweendevices.SHDSLcableTransmitsmultipletypesofsignals,includingvoice,data,andvideosignals.Synchronous/Asyn-chronousserialcableTransmitssynchronous/asynchronoussignals.SignalcablesE1trunkcableTransmitsE1trunksignals.TableofContentsPowerCablesandGroundingCables.......................................................................10-1SignalCables...........................................................................................................10-410.1PowerCablesandGroundingCables10.1.1DCPowerCablesADCpowercableoftheZXR10ZSRV2isablack/bluere-retardantPVCinsulatedcable,seeFigure10-1.10-1SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionFigure10-1DCPowerCable1.D-type3-corestraightsolderconnector(hole+pin+hole,withprotectiveedges)2.12AWGbluemulti-strandheat-resistantcable3.12AWGblackUL1015cable4.Pre-insulatedtubeterminal10-2SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter10CablesFortherelationshipbetweenDCpowercablecorewiresandpinpositions,refertoTable10-2.Table10-2CoreWiresofaDCPowerCableEndAColorEndBTagA1BlackB2-48VRTNA3BlueB1-48VCaution!DCpowercablesoftheZXR10ZSRV2arededicatedcables.Itisforbiddentousethemforotherpurposes.10.1.2ACPowerCablesFortheoverviewofanACpowercableoftheZXR10ZSRV2,seeFigure10-2.Figure10-2ACPowerCable1.10Ainternationalstandard3-pinflatmaleplug2.3×0.75mm2powercable(with3Ccertification)3.10AinternationalstandardT-shapedfemaleplugForthemodelsandspecicationsoftheACpowercablesoftheZXR10ZSRV2,refertoTable10-3.Table10-3TechnicalParametersofanACPowerCableItemDescription10Ainternationalstandard3-pinatmaleplug Terminalmodel10AinternationalstandardT-shapedfemaleplugCablemodel3×0.0012sq.in.(0.75mm2),with3Ccertication10-3SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescription10.1.3GroundingCablesGroundingcablesconnectacabinet,chassis,orcabinetdoortothegroundtoguaranteesafepowersupply.Agroundingcableisayellowgreencopper-corecable,seeFigure10-3Figure10-3OverviewofaProtectiveGroundingCable10.2SignalCables10.2.1AUXCablesTheAUXcableisan8-coreshieldedcable.OneendofthecableisanRJ45connectorconnectingtotheMPUAUXinterface.Theotherendconnectstothecomputerserialport.ForanAUXcableconnectedtotheDB9port,seeFigure10-4.Figure10-4AUXCable(DB9)1.D-type9-corestraightplasticinjectionmold(hole)2.CAT5enetworkcable3.8P8CstraightcablecrimpshieldedplugFortherelationshipbetweenAUXcable(DB9)corewiresandpinpositions,refertoT able10-4.Table10-4CoreWiresofanAUXCableRJ45PinPCBAUXSignalSignalDirectionDB9PinPCDB9(Hole)SignalModemDB-9(Pin)PinModemDB-9(Pin)Signal1CTS←7RTS8CTS2DTR→6DSR4DTR3TXD→2RXD3TXD4DCD←1DCD1DCD5GND—5GND5GND6RXD←3TXD2RXD10-4SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter10CablesRJ45PinPCBAUXSignalSignalDirectionDB9PinPCDB9(Hole)SignalModemDB-9(Pin)PinModemDB-9(Pin)Signal7DSR←4DTR6DSR8RTS→8CTS7RTS10.2.2ConsoleCablesConnectingtheZXR10ZSRV2consoleporttotheconsoleserialport,theconsolecabletransmitsdevicecongurationdata.Theconsolecommunicationcableisan8-coreshieldedcable.OneendofthecableisanRJ45connectorconnectingtotheMPUconsoleport.Theotherendconnectstotheserverserialport.Fortheoverviewoftheconsolecable,seeFigure10-5.Figure10-5ConsoleCableStructure1.D-type9-coreplasticinjectionmoldedcableplug(hole)2.Label/self-coveringwinderlaserprint(typeII)3.HorizontaltwistedpairSBVVP-2×24.8P8CstraightcablesolderconnectorFortherelationshipbetweenconsolecablecorewiresandpinpositions,refertoTable10-5.Table10-5CoreWiresofaConsoleCableRJ45PinPCBCONSOLESignalSignalDirectionDB9PinPCDB9(Hole)Signal1Nosignalincaseofthreewires←7RTS2Nosignalincaseofthreewires→6DSR3TXD→2RXD4GND←1DCD10-5SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionRJ45PinPCBCONSOLESignalSignalDirectionDB9PinPCDB9(Hole)Signal5GND—5GND6RXD←3TXD7DSR←4DTR8RTS→8CTS10.2.3EthernetCablesTherearetwotypesofEthernetcables,crossovercablesandstraight-throughcables.Straight-throughEthernetcablesareusedinthefollowingcases:lEthernetconnectionbetweenZXR10ZSRV2andalineconcentrator.lEthernetconnectionbetweenZXR10ZSRV2andanEthernetswitch.lEthernetconnectionbetweenacomputerandalineconcentrator.lEthernetconnectionbetweenacomputerandanEthernetswitch.CrossoverEthernetcablesareusedinthefollowingcases:lEthernetconnectionbetweentwoZXR10ZSRV2devices.lEthernetconnectionbetweenZXR10ZSRV2andacomputerEthernetcard.lEthernetconnectionbetweentwolineconcentrators.lEthernetconnectionbetweenalineconcentratorandanEthernetswitch.lEthernetconnectionbetweentwoEthernetswitches.lEthernetcardconnectionbetweentwocomputers.AnEthernetcableconsistsofRJ45connectorsandaneight-wiretwistedpaircable.ForanoverviewoftheEthernetcable,seeFigure10-6.Figure10-6Ethernetcable1.Ethernetcableconnector2.StandardshieldedEthernetcable3.CablelabelForthewiringsequenceofthestraight-throughEthernetcable,refertoTable10-6.10-6SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter10CablesTable10-6WiringSequenceoftheStraight-ThroughEthernetCableColorEndAEndBColorWhite/orange11White/orangeOrange22OrangeWhite/green33White/greenBlue44BlueWhite/blue55White/blueGreen66GreenWhite/brown77White/brownBrown88BrownForthewiringsequenceofthecross-overEthernetcable,refertoT able10-7.Table10-7WiringSequenceoftheCross-OverEthernetCableColorEndAEndBColorWhite/orange13White/greenOrange26GreenWhite/green31White/orangeBlue44BlueWhite/blue55White/blueGreen62OrangeWhite/brown77White/brownBrown88BrownForthetechnicalparametersoftheEthernetcable,refertoTable10-8.Table10-8TechnicalParametersoftheEthernetCableCableconnector8P8CstraightcablecrimpconnectorModelE5088-001023TechnicalparameterRatedcurrent:1.5A,ratedvoltage:125V,connectedtoASG24-28#gaugeroundwires10.2.4OpticalFibersOverviewTheopticalberisacommunicationmediumthatusesabundleofthinglassrodstotransmitthemodulatedlight.Therearetwotypesofopticalbers,single-modeoptical10-7SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionbersandmultimodeopticalbers.Theusermayselectoneinaccordancewiththeparticularsituation.lMultimodeopticalber:Transmitssignalsbyusingmultiplemodesoflight(forshort-distancetransmission).lSingle-modeopticalber:Transmitssignalsbyusingasinglemodeoflight(forlong-distancetransmission).Eachopticalberiscomposedofthebercore,claddinglayer,bufferlayer,strengtheninglayer,andtheouterjacket.Forthephysicalcross-sectionalareaofabercable,seeFigure10-7.Figure10-7OpticalFiberCross-sectionalAreaThebercoreistheopticaltransmissioncomponentlocatedatthecore.Itismadeofsiliconorglass.Thechemicalcompositionsofabercorearepartiallydifferentfromthoseofthecladdinglayer,sothatthelightenteringataspeciedangleisreectedcontinuouslybythebercoreandcladdinglayer.Therefore,lightremainsinthebercoreduringthewholetransmissionprocess.OpticalFiberConnectorsSelectionofopticalberconnectorsdependsontheoperatingenvironmentanddevices.TheZXR10ZSRV2routerusesthefollowingtypesofopticalberconnectors:lLCconnectorlSCconnectorlFCconnectorConnectorsatthetwoendsoftheopticalbercanbeofthesametypeordifferenttypes.Fortheconnectorpairingandusage,refertoTable10-9.Table10-9OpticalFiberConnectorPairingandUsageDevice-endConnectortypeOpposite-endConnectortypeCableTypeCableUsageLCFCSingle-modeindooropticalberConnectionbetweenadeviceinterfacelinecardandODF10-8SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter10CablesDevice-endConnectortypeOpposite-endConnectortypeCableTypeCableUsageLCLCSingle-modeindooropticalberConnectionbetweeninterfacelinecardsLCSCMultimodeindooropticalberConnectionbetweeninterfacelinecardsLCSCSingle-modeindooropticalberConnectionbetweenaninterfacelinecardandothertypesofdevicesLCLCMultimodeindooropticalberConnectionbetweenaninterfacelinecardandothertypesofdevicesInterfaceboardsoftheZXR10ZSRV2mainlyuseLC-typeconnectors,seeFigure10-8.Figure10-8LC-typeFiberConnector10.2.5SHDSLCablesAnSHDSLcableisaneight-coreCAT5e100-ohmnon-shieldedtwistedpaircable.OneendisconnectedtooneRJ45connector,andtheotherendisconnectedtofourRJ11connectors.TheSHDSLcablescanbeusedfortransmittingmultipletypesofsignals,includingvoice,data,andvideosignals.ForanoverviewoftheSHDSLcable,seeFigure10-9.Figure10-9SHDSLCable1.RJ45connector2.Eight-coreCAT5e100-ohmnon-shieldedtwistedpaircable3.RJ11connector10-9SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionAnSHDSLcableprovidesfourports(twowiresforeachport)attheRJ11connectorside.ForthewiringsequenceoftheSHDSLcable,refertoTable10-10.Table10-10WiringSequenceoftheSHDSLCablePinNumberatEndAColorPinNumberatEndBLabel4(Line0A)White/green35(Line0B)Green4B1port11(Line1A)White/orange32(Line1B)Orange4B2port23(Line2A)White/blue36(Line2B)Blue4B3port37(Line3A)White/brown38(Line3B)Brown4B4port4ForthetechnicalparametersoftheSHDSLcable,refertoTable10-11.Table10-11TechnicalParametersoftheSHDSLCableParameterSpecicationImpedance100ohmsCabletypeSymmetricCAT5etwistedpaircableWiregauge(innerconductor)24AWGCore810.2.6Synchronous/AsynchronousSerialCableTheZXR10ZSRV2seriesroutersusesynchronousorasynchronousserialcablestotransmitsynchronousorasynchronoussignals.Theserialcablescanbedividedintothefollowingtypes:lV.35/V.24DTEcable(RA-DTE-DB50-DB25):ADB25maleconnectorisusedatthenetworkend.lV.35/V.24DCEcable(RA-DCE-DB50-DB25):ADB25femaleconnectorisusedatthenetworkend.lV.35/V.24DTEcable(RA-DTE-DB50-34pole):A34polemaleconnectorisusedatthenetworkend.lV.35/V.24DCEcable(RA-DCE-DB50-34pole):A34polefemaleconnectorisusedatthenetworkend.ForanoverviewoftheV.35/V.24DTEcable(RA-DTE-DB50-DB25),seeFigure10-10.10-10SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter10CablesFigure10-10V.35/V.24DTECable(RA-DTE-DB50-DB25)1.Device-endconnectorDB502.Network-endconnectorDB25(male)ForanoverviewoftheV.35/V.24DCEcable(RA-DCE-DB50-DB25),seeFigure10-11.Figure10-11V.35/V.24DCECable(RA-DCE-DB50-DB25)1.Device-endconnectorDB502.Network-endconnectorDB25(female)ForanoverviewoftheV.35/V.24DTEcable(RA-DTE-DB50-34pole),seeFigure10-12.10-11SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionFigure10-12V.35/V.24DTECable(RA-DTE-DB50-34pole)1.Device-endconnectorDB502.Network-endconnector34pole(male)ForanoverviewoftheV.35/V.24DCEcable(RA-DCE-DB50-34pole),seeFigure10-13.Figure10-13V.35/V.24DCECable(RA-DCE-DB50-34pole)1.Device-endconnectorDB502.Network-endconnector34pole(female)Foradescriptionofthesynchronous/asynchronousserialcabletypes,refertoT able10-12.10-12SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter10CablesTable10-12Synchronous/AsynchronousSerialCableTypesSynchronous/AsynchronousSerialCableDevice-EndConnectorNetwork-EndConnectorV.35/V.24DTEcable(RA-DTE-DB50-DB25)DB50DB25maleconnectorV.35/V.24DCEcable(RA-DCE-DB50-DB25)DB50DB25femaleconnectorV.35/V.24DTEcable(RA-DTE-DB50-34pole)DB5034polemaleconnectorV.35/V.24DCEcable(RA-DCE-DB50-34pole)DB5034polefemaleconnector10.2.7E1TrunkCableOverviewTheE1trunkcablesthattheRAC-PIU-16CE1andRAC-PIU-16CE1-CESboardsoftheZXR10ZSRV2seriesroutersusecanbedividedintothefollowingtypes:l75ΩunbalancedcoaxialcableIftheinterfaceresistanceoftheRAC-PIU-16CE1orRAC-PIU-16CE1-CESboardisconguredto75Ω,the75ΩunbalancedcoaxialcableisusedastheE1trunkcable.l120Ωbalancedtwisted-paircableIftheinterfaceresistanceoftheRAC-PIU-16CE1orRAC-PIU-16CE1-CESboardisconguredto120Ω,the120Ωbalancedtwisted-paircableisusedastheE1trunkcable.FortheE1trunkcableconnections,refertoTable10-13.Table10-13E1TrunkCableConnectionsSynchronous/Asyn-chronousSerialCableDevice-EndConnectorNetwork-EndConnector75ΩunbalancedcoaxialcableDB50Sixteencoaxialcablesintwogroups,connectedtotheconnectorsasrequired120Ωbalancedtwisted-paircableDB50Sixteentwisted-paircablesintwogroups,connectedtotheconnectorsasrequired75ΩUnbalancedCoaxialCableForanoverviewofthe75Ωunbalancedcoaxialcable,seeFigure10-14.10-13SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionFigure10-1475ΩUnbalancedCoaxialCable1.Device-endDB50connector2.8-coremicro-coaxialA3.8-coremicro-coaxialB4.Pin1atendA5.Pin25atendA6.Pin50atendA7.Pin26atendAForthecorrespondencerelationshipsbetweentheend-Apinsandtheend-B1coresofthe75Ωunbalancedcoaxialcable,refertoTable10-14.Table10-14CorrespondenceRelationshipsBetweentheEnd-APinsandEnd-B1Coresofthe75ΩUnbalancedCoaxialCablePinatEndAEndB1(Eight-CoreMicro-CoaxialA)Signal25A-1coreR1+50A-1shieldR1–24A-2coreT1+49A-2shieldT1–23A-3coreR2+48A-3shieldR2–22A-4coreT2+47A-4shieldT2–21A-5coreR3+46A-5shieldR3–20A-6coreT3+45A-6shieldT3–10-14SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter10CablesPinatEndAEndB1(Eight-CoreMicro-CoaxialA)Signal19A-7coreR4+44A-7shieldR4–18A-8coreT4+43A-8shieldT4–Forthecorrespondencerelationshipsbetweentheend-Apinsandtheend-B2coresofthe75Ωunbalancedcoaxialcable,refertoTable10-15.Table10-15CorrespondenceRelationshipsBetweentheEnd-APinsandEnd-B2Coresofthe75ΩUnbalancedCoaxialCablePinatEndAEndB2(Eight-CoreMicro-CoaxialB)Signal17B-1coreR5+42B-1shieldR5–16B-2coreT5+41B-2shieldT5–15B-3coreR6+40B-3shieldR6–14B-4coreT6+39B-4shieldT6–13B-5coreR7+38B-5shieldR7–12B-6coreT7+37B-6shieldT7–11B-7coreR8+36B-7shieldR8–10B-8coreT8+35B-8shieldT8–120ΩBalancedTwisted-PairCableForanoverviewofthe120Ωbalancedtwisted-paircable,seeFigure10-15.10-15SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionFigure10-15120ΩBalancedTwisted-PairCable1.Device-endconnectorDB502.8-coremicro-coaxialA3.8-coremicro-coaxialB4.Pin1atendA5.Pin25atendA6.Pin50atendA7.Pin26atendAForthecorrespondencerelationshipsbetweentheend-Apinsandtheend-B1coresofthe120Ωbalancedtwisted-paircable,refertoT able10-16.Table10-16CorrespondenceRelationshipsBetweentheEnd-APinsandEnd-B1Coresofthe120ΩBalancedTwisted-PairCablePinatEndAEndB1(16-CoreCableA)Signal25BlueR1+50WhiteTwistedpairR1–24OrangeT1+49WhiteTwistedpairT1–23GreenR2+48WhiteTwistedpairR2–22BrownT2+47WhiteTwistedpairT2–21GreyR3+46WhiteTwistedpairR3–20BlueT3+45RedTwistedpairT3–19OrangeR4+44RedTwistedpairR4–10-16SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
Chapter10CablesPinatEndAEndB1(16-CoreCableA)Signal18GreenT4+43RedTwistedpairT4–Forthecorrespondencerelationshipsbetweentheend-Apinsandtheend-B2coresofthe120Ωbalancedtwisted-paircable,refertoT able10-17.Table10-17CorrespondenceRelationshipsBetweentheEnd-APinsandEnd-B2Coresofthe120ΩBalancedTwisted-PairCablePinatEndAEndB2(16-CoreCableB)Signal17BlueR5+42WhiteTwistedpairR5–16OrangeT5+41WhiteTwistedpairT5–15GreenR6+40WhiteTwistedpairR6–14BrownT6+39WhiteTwistedpairT6–13GreyR7+38WhiteTwistedpairR7–12BlueT7+37RedTwistedpairT7–11OrangeR8+36RedTwistedpairR8–10GreenT8+35RedTwistedpairT8–10-17SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionThispageintentionallyleftblank.10-18SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
AppendixABoardQuickTable(WeightandPowerConsumption)FortheweightandpowerconsumptionoftheboardssupportedbytheZXR10ZSRV2seriesrouters,refertoTableA-1.TableA-1BoardWeightandPowerConsumptionoftheZXR10ZSRV2SeriesRoutersBoardTypeSilkScreenNameWeightPowerConsumptionRAC-2838-MPFU-A2.38lb.(1.08kg)35WRAC-2838-MPFU-B2.38lb.(1.08kg)35WMPFURAC-2838-MPFU-C2.38lb.(1.08kg)35WRAE-DPIU-OSU-A12.71lb.(1.23kg)40WRAE-DPIU-OSU-A22.71lb.(1.23kg)40WGeneralprocessingboardRAE-DPIU-FW-A2.31lb.(1.05kg)35WRAC-SPIU-02CE1-750.53lb.(0.24kg)6WRAC-SPIU-02CE1-1200.53lb.(0.24kg)6WRAC-SPIU-02UE1-750.53lb.(0.24kg)6WRAC-SPIU-02UE1-1200.53lb.(0.24kg)6WRAC-SPIU-02HS0.46lb.(0.21kg)7WRAC-SPIU-04GE0.22lb.(0.1kg)7WRAC-PIU-LTE1.23lb.(0.56kg)7WRAC-PIU-01DSLB0.88lb.(0.4kg)16WRAC-PIU-04SHDSL1.19lb.(0.54kg)10WRAC-PIU-04HS1.19lb.(0.54kg)10WRAC-PIU-04CE1-751.19lb.(0.54kg)11WRAC-PIU-04CE1-1201.19lb.(0.54kg)11WRAC-PIU-04UE1-751.19lb.(0.54kg)11WRAC-PIU-04UE1-1201.19lb.(0.54kg)11WRAC-PIU-16CE11.19lb.(0.54kg)16WRAC-PIU-16CE1-CES1.19lb.(0.54kg)16WRAC-PIU-01P12-SFP1.19lb.(0.54kg)16WPIUA-1SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionBoardTypeSilkScreenNameWeightPowerConsumptionRAC-PIU-02P3-SFP1.19lb.(0.54kg)16.5WRAC-PIU-04P3-SFP1.19lb.(0.54kg)18WRAC-PIU-02CP3-SFP1.19lb.(0.54kg)16.5WRAC-PIU-04CP3-SFP1.19lb.(0.54kg)18WRAC-PIU-04GE-SFP1.19lb.(0.54kg)13WRAC-PIU-08GE-SFP1.19lb.(0.54kg)15WRAC-PIU-05GE-4E1SFP0.88lb.(0.4kg)11WRAC-PIU-09GE-8E1SFP1.19lb.(0.54kg)12WRAC-PIU-08FE1GE-1SFP1.19lb.(0.54kg)11WRAC-DPIU-16GE-12SFP4E1.32lb.(0.6kg)36WRAC-DPIU-01XGE-SFP+1.50lb.(0.68kg)16WA-2SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
AppendixBOpticalModulesQuickTableOverviewZXR10ZSRV2routersusetheSFPopticalmodules,refertoT ableB-1.TableB-1SFPOpticalModulesTypeExampleSFP(SmallForm-factorPluggable)IndicatorsAnopticalmodulealwayshastheACTandLNKindicators.Forindicatordescriptions,refertoT ableB-2.TableB-2OpticalModuleIndicatorDescriptionsIndicatorColorDescriptionACTGreenTransmissionstatusindicatorofanopticalport.Whendataisbeingtransmitted,thisindicatorashes.LNKGreenPhysicalconnectionstatusindicatorofanopticalport.Ifthephysicalconnectionoftheopticalportisnormal,thisindicatorison.Otherwise,thisindicatorisoff.SFPAttributesFortheattributesofan155MSFPopticalmodule,refertoT ableB-3.TableB-3155MSFPAttributesAttributeParametersTransmissiondistance(km)2154080100Centralwavelength(nm)13101310131015501310Referencewavelengthrange(nm)1260~15701261~13601263~13601480~15801480~1580Transmittingopticalpowerrange(dBm)-19~-14-15~-8-5~0-5~00~5B-1SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionAttributeParametersReceivingsensitivity(dBm)-30-28-34-34-34Overloadopticalpower(dBm)-10-8-10-10-10FibertypeMultimodeSinglemodeSinglemodeSinglemodeSinglemodeInterfacetypeLC-SFPLC-SFPLC-SFPLC-SFPLC-SFPFortheattributesofan622MSFPopticalmodule,refertoT ableB-4.TableB-4622MSFPAttributesAttributeParametersTransmissiondistance(km)154080Centralwavelength(nm)131013101550Referencewavelengthrange(nm)1274~13561280~13351480~1580Transmittingopticalpowerrange(dBm)-15~-8-3~2-3~2Receivingsensitivity(dBm)-28-28-28Overloadopticalpower(dBm)-8-8-8FibertypeSinglemodeSinglemodeSinglemodeInterfacetypeLC-SFPLC-SFPLC-SFPFortheattributesofan1.25GSFPopticalmodule,refertoT ableB-5.TableB-51.25GSFPAttributesAttributeParametersTransmissiondistance(km)0.510404080120Centralwavelength(nm)85013101310155015501550Referencewavelengthrange(nm)770~8601260~13601260~13601480~15801480~15801480~1580B-2SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
AppendixBOpticalModulesQuickT ableAttributeParametersTransmittingopticalpowerrange(dBm)-9.5~-3-11.5~-3-4.5~5-5~0-2~50~5Receivingsensitivity(dBm)-17-19-22-22-22-30Overloadopticalpower(dBm)0-3-5-3-5-9FibertypeMultimodeSinglemodeSinglemodeSinglemodeSinglemodeSinglemodeInterfacetypeLC-SFPLC-SFPLC-SFPLC-SFPLC-SFPLC-SFPB-3SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionThispageintentionallyleftblank.B-4SJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
FiguresFigure2-1MainComponentsontheFrontSideoftheZXR103800-8Chassis...........2-1Figure2-2FrontViewoftheZXR103800-8Chassis.................................................2-2Figure2-3FrontViewoftheZXR103800-8Chassis.................................................2-2Figure2-4PaneloftheACPowerSupplyModule.....................................................2-4Figure2-5PaneloftheDCPowerSupplyModule....................................................2-5Figure3-1MainComponentsontheFrontSideoftheZXR102800-4Chassis...........3-1Figure3-2FrontViewoftheZXR102800-4Chassis.................................................3-2Figure3-3FrontViewoftheZXR102800-4Chassis.................................................3-2Figure3-4PaneloftheACPowerSupplyModule.....................................................3-4Figure3-5PaneloftheDCPowerSupplyModule....................................................3-5Figure4-1ZXR101800-2SFrontView.....................................................................4-2Figure4-2ZXR101800-2SFrontPanel....................................................................4-2Figure4-3ZXR101800-2SRearPanel....................................................................4-3Figure4-4FrontViewoftheZXR101800-2SChassis..............................................4-4Figure4-5PowerButton...........................................................................................4-6Figure5-1FrontStructureGraphforaZXR102800-3EChassis...............................5-2Figure5-2FrontPanelofaZXR102800-3EChassis................................................5-2Figure5-3BackPanelofaZXR102800-3EChassis................................................5-3Figure5-4SlotsontheBackofaZXR102800-3EChassis.......................................5-3Figure5-5PaneloftheACPowerModule................................................................5-5Figure5-6PaneloftheDCPowerModule................................................................5-6Figure6-1FrontViewofaZXR101800-2EChassis.................................................6-2Figure6-2FrontPanelofaZXR101800-2EChassis................................................6-2Figure6-3BackPanelofaZXR101800-2EChassis................................................6-3Figure6-4SlotsontheBackofaZXR101800-2EChassis.......................................6-3Figure6-5PaneloftheACPowerModule................................................................6-5Figure6-6PaneloftheDCPowerModule................................................................6-6Figure7-1PaneloftheRAC-2838-MPFU-A.............................................................7-2Figure7-2RAC-2838-MPFU-BandRAC-2838-MPFU-C..........................................7-3Figure8-1PanelofanRAC-DPIU-OSU-A1Board....................................................8-1Figure8-2PanelofanRAC-DPIU-OSU-A2Board....................................................8-3Figure8-3PanelofanRAC-DPIU-FW-ABoard........................................................8-5ISJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionFigure9-1FrontPaneloftheRAC-SPIU-02CE1-75Board.......................................9-2Figure9-2FrontPaneloftheRAC-SPIU-02UE1-75Board.......................................9-4Figure9-3FrontPaneloftheRAC-SPIU-02CE1-120Board.....................................9-5Figure9-4FrontPaneloftheRAC-SPIU-02UE1-120Board.....................................9-7Figure9-5FrontPaneloftheRAC-SPIU-02HSBoard..............................................9-8Figure9-6FrontPanelofanRAC-SPIU-04GEBoard.............................................9-10Figure9-7RAC-PIU-LTEBoardPanel....................................................................9-11Figure9-8FrontPaneloftheRAC-PIU-01DSLBBoard..........................................9-13Figure9-9FrontPaneloftheRAC-PIU-04SHDSLboard........................................9-15Figure9-10FrontPaneloftheRAC-PIU-04HSBoard.............................................9-17Figure9-11FrontPaneloftheRAC-PIU-04CE1-75Board......................................9-18Figure9-12FrontPaneloftheRAC-PIU-04CE1-120Board....................................9-20Figure9-13FrontPaneloftheRAC-PIU-04UE1-75Board......................................9-21Figure9-14FrontPaneloftheRAC-PIU-04UE1-120Board....................................9-22Figure9-15FrontPaneloftheRAC-PIU-16CE1Board...........................................9-24Figure9-16FrontPaneloftheRAC-PIU-16CE1-CESBoard..................................9-25Figure9-17FrontPaneloftheRAC-PIU-01P12-SFPBoard...................................9-27Figure9-18FrontPaneloftheRAC-PIU-02P3-SFPBoard.....................................9-28Figure9-19FrontPaneloftheRAC-PIU-04P3-SFPBoard.....................................9-29Figure9-20FrontPaneloftheRAC-PIU-02CP3-SFPBoard...................................9-31Figure9-21FrontPaneloftheRAC-PIU-04CP3-SFPBoard...................................9-32Figure9-22FrontPaneloftheRAC-PIU-04GE-SFPBoard.....................................9-34Figure9-23FrontPaneloftheRAC-PIU-08GE-SFPBoard.....................................9-35Figure9-24FrontPaneloftheRAC-PIU-05GE-4E1SFPBoard..............................9-37Figure9-25FrontPaneloftheRAC-PIU-09GE-8E1SFPBoard..............................9-39Figure9-26FrontPaneloftheRAC-PIU-08FE1GE-1SFPBoard............................9-41Figure9-27FrontPaneloftheRAC-DPIU-16GE-12SFP4EBoard..........................9-43Figure9-28FrontPaneloftheRAC-DPIU-01XGE-SFP+Board...............................9-45Figure10-1DCPowerCable..................................................................................10-2Figure10-2ACPowerCable..................................................................................10-3Figure10-3OverviewofaProtectiveGroundingCable...........................................10-4Figure10-4AUXCable(DB9).................................................................................10-4Figure10-5ConsoleCableStructure......................................................................10-5Figure10-6Ethernetcable......................................................................................10-6Figure10-7OpticalFiberCross-sectionalArea.......................................................10-8IISJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
FiguresFigure10-8LC-typeFiberConnector......................................................................10-9Figure10-9SHDSLCable......................................................................................10-9Figure10-10V.35/V.24DTECable(RA-DTE-DB50-DB25)...................................10-11Figure10-11V.35/V.24DCECable(RA-DCE-DB50-DB25)...................................10-11Figure10-12V.35/V.24DTECable(RA-DTE-DB50-34pole).................................10-12Figure10-13V.35/V.24DCECable(RA-DCE-DB50-34pole).................................10-12Figure10-1475ΩUnbalancedCoaxialCable......................................................10-14Figure10-15120ΩBalancedTwisted-PairCable.................................................10-16IIISJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
FiguresThispageintentionallyleftblank.IVSJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
TablesTable1-1ComponentModels...................................................................................1-1Table2-1DescriptionoftheMainComponentsoftheZXR103800-8Chassis...........2-2Table2-2SystemParametersoftheZXR103800-8.................................................2-3Table2-3IndicatorDescriptionsfortheZXR103800-8ACPowerSupplyModule.....................................................................................................2-4Table2-4PowerButtonDescriptionfortheZXR103800-8ACPowerSupplyModule.....................................................................................................2-5Table2-5TechnicalParametersoftheACPowerRectieroftheZXR103800-8.....................................................................................................2-5Table2-6IndicatorDescriptionsfortheZXR103800-8DCPowerSupplyModule.....................................................................................................2-6Table2-7PowerButtonDescriptionfortheZXR103800-8DCPowerSupplyModule.....................................................................................................2-6Table2-8T echnicalParametersoftheDCPowerSupplyModuleoftheZXR103800-8.....................................................................................................2-6Table2-9ZXR103800-8FanSpecications.............................................................2-7Table3-1DescriptionoftheMainComponentsoftheZXR102800-4Chassis...........3-2Table3-2SystemParametersoftheZXR102800-4.................................................3-3Table3-3IndicatorDescriptionsfortheZXR102800-4ACPowerSupplyModule.....................................................................................................3-4Table3-4PowerButtonDescriptionfortheZXR102800-4ACPowerSupplyModule.....................................................................................................3-4Table3-5TechnicalParametersoftheACPowerRectieroftheZXR102800-4.....................................................................................................3-5Table3-6IndicatorDescriptionsfortheZXR102800-4DCPowerSupplyModule.....................................................................................................3-5Table3-7PowerButtonDescriptionfortheZXR102800-4DCPowerSupplyModule.....................................................................................................3-6Table3-8T echnicalParametersoftheDCPowerSupplyModuleoftheZXR102800-4.....................................................................................................3-6Table3-9ZXR102800-4FanSpecications.............................................................3-6Table4-1DescriptionsoftheMainComponentsoftheZXR101800-2S...................4-1Table4-2ZXR101800-2SFrontPanelDescriptions.................................................4-2Table4-3ZXR101800-2SRearPanelDescriptions..................................................4-4VSJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionTable4-4SystemParametersoftheZXR101800-2S...............................................4-5Table4-5PowerButtonDescriptionfortheZXR101800-2SACPowerSupplyModule.....................................................................................................4-6Table4-6TechnicalParametersoftheACPowerRectieroftheZXR101800-2S...................................................................................................4-6Table4-7TechnicalParametersoftheDCPowerRectieroftheZXR101800-2S...................................................................................................4-7Table5-1MainComponentsofaZXR102800-3EChassis.......................................5-1Table5-2DescriptionsofInterfacesontheFrontPanelofaZXR102800-3EChassis....................................................................................................5-2Table5-3SystemParametersofaZXR102800-3EChassis.....................................5-4Table5-4FunctionsoftheIndicatorsonthePaneloftheACPowerModuleoftheZXR102800-3EChassis..........................................................................5-5Table5-5FunctionsofthePowerButtonsoftheACPowerModuleoftheZXR102800-3EChassis......................................................................................5-6Table5-6TechnicalParametersoftheACPoweroftheZXR102800-3EChassis....................................................................................................5-6Table5-7FunctionsoftheIndicatorsonthePaneloftheDCPowerModuleoftheZXR102800-3EChassis..........................................................................5-7Table5-8FunctionsofthePowerButtonsoftheDCPowerModuleoftheZXR102800-3EChassis......................................................................................5-7Table5-9T echnicalParametersoftheDCPowerModuleoftheZXR102800-3EChassis....................................................................................................5-7Table6-1MainComponentsofaZXR101800-2EChassis.......................................6-1Table6-2DescriptionsofInterfacesontheFrontPanelofaZXR101800-2EChassis....................................................................................................6-2Table6-3SystemParametersofaZXR101800-2EChassis.....................................6-4Table6-4FunctionsoftheIndicatorsonthePaneloftheACPowerModuleoftheZXR101800-2EChassis..........................................................................6-5Table6-5FunctionsofthePowerButtonsoftheACPowerModuleoftheZXR101800-2EChassis......................................................................................6-5Table6-6TechnicalParametersoftheACPoweroftheZXR101800-2EChassis....................................................................................................6-6Table6-7FunctionsoftheIndicatorsonthePaneloftheDCPowerModuleoftheZXR101800-2EChassis..........................................................................6-6Table6-8FunctionsofthePowerButtonsoftheDCPowerModuleoftheZXR101800-2EChassis......................................................................................6-7Table6-9T echnicalParametersoftheDCPowerModuleoftheZXR101800-2EChassis....................................................................................................6-7VISJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
TablesTable7-1DescriptionoftheInterfacesoftheRAC-2838-MPFU-A............................7-2Table7-2IndicatorDescriptionsfortheRAC-2838-MPFU-A.....................................7-2Table7-3RSTButtonDescriptionfortheRAC-2838-MPFU-A..................................7-3Table7-4TechnicalParametersoftheRAC-2838-MPFU-A......................................7-3Table7-5DescriptionoftheInterfacesoftheRAC-2838-MPFU-B/RAC-2838-MPFU-C.................................................7-4Table7-6DescriptionoftheIndicatorsonthePaneloftheRAC-2838-MPFU-B/RAC-2838-MPFU-C.................................................7-4Table7-7DescriptionoftheRSTButtononthePaneloftheRAC-2838-MPFU-B/RAC-2838-MPFU-C.................................................7-4Table7-8TechnicalParametersoftheRAC-2838-MPFU-B/RAC-2838-MPFU-C.................................................7-5Table8-1DescriptionsofInterfacesontheRAC-DPIU-OSU-A1Board.....................8-2Table8-2FunctionsoftheIndicatorsonthePaneloftheRAC-DPIU-OSU-A1Board.......................................................................................................8-2Table8-3FunctionsoftheButtonsonthePaneloftheRAC-DPIU-OSU-A1Board.......................................................................................................8-2Table8-4TechnicalParametersoftheRAC-DPIU-OSU-A1Board............................8-2Table8-5DescriptionofInterfacesontheRAC-DPIU-OSU-A2Board.......................8-3Table8-6FunctionsoftheIndicatorsonthePaneloftheRAC-DPIU-OSU-A2Board.......................................................................................................8-4Table8-7FunctionsoftheButtonsonthePaneloftheRAC-DPIU-OSU-A2Board.......................................................................................................8-4Table8-8TechnicalParametersoftheRAC-DPIU-OSU-A2Board............................8-4Table8-9DescriptionofInterfacesonanRAC-DPIU-FW-ABoard............................8-5Table8-10FunctionsofIndicatorsonthePanelofanRAC-DPIU-FW-ABoard.......................................................................................................8-5Table8-11FunctionsofButtonsonthePanelofanRAC-DPIU-FW-ABoard............8-5Table8-12TechnicalParametersofanRAC-DPIU-FW-ABoard...............................8-6Table9-1LineInterfaceBoardTypes........................................................................9-1Table9-2InterfacePropertiesoftheRAC-SPIU-02CE1-75Board............................9-3Table9-3DescriptionoftheIndicatorsonthePaneloftheRAC-SPIU-02CE1-75Board.......................................................................................................9-3Table9-4TechnicalParametersoftheRAC-SPIU-02CE1-75Board.........................9-3Table9-5InterfacePropertiesoftheRAC-SPIU-02UE1-75Board............................9-4Table9-6DescriptionoftheIndicatorsonthePaneloftheRAC-SPIU-02UE1-75Board.......................................................................................................9-4Table9-7TechnicalParametersoftheRAC-SPIU-02UE1-75Board.........................9-5VIISJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionTable9-8InterfacePropertiesoftheRAC-SPIU-02CE1-120Board..........................9-5Table9-9DescriptionoftheIndicatorsonthePaneloftheRAC-SPIU-02CE1-120Board.......................................................................................................9-6Table9-10TechnicalParametersoftheRAC-SPIU-02CE1-120Board.....................9-6Table9-11InterfacePropertiesoftheRAC-SPIU-02UE1-120Board.........................9-7Table9-12DescriptionoftheIndicatorsonthePaneloftheRAC-SPIU-02UE1-120Board.......................................................................................................9-7Table9-13TechnicalParametersoftheRAC-SPIU-02UE1-120Board.....................9-7Table9-14InterfacePropertiesoftheRAC-SPIU-02HSBoard.................................9-8Table9-15DescriptionoftheIndicatorsonthePaneloftheRAC-SPIU-02HSBoard.......................................................................................................9-9Table9-16TechnicalParametersoftheRAC-SPIU-02HSBoard..............................9-9Table9-17AttributesofInterfacesonanRAC-SPIU-04GEBoard...........................9-10Table9-18DescriptionofFunctionsoftheIndicatorsonthePaneloftheRAC-SPIU-04GEBoard.........................................................................9-10Table9-19TechnicalParametersofanRAC-SPIU-04GEBoard.............................9-10Table9-20RAC-PIU-LTEBoardIndicatorDescriptions...........................................9-12Table9-21RAC-PIU-LTEBoardTechnicalSpecications.......................................9-13Table9-22InterfacePropertiesoftheRAC-PIU-01DSLBBoard..............................9-13Table9-23DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-01DSLBBoard.....................................................................................................9-14Table9-24TechnicalParametersoftheRAC-PIU-01DSLBBoard..........................9-14Table9-25InterfacePropertiesoftheRAC-PIU-04SHDSLBoard...........................9-15Table9-26DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04SHDSLBoard.....................................................................................................9-16Table9-27TechnicalParametersoftheRAC-PIU-04SHDSLBoard........................9-16Table9-28InterfacePropertiesoftheRAC-PIU-04HSBoard..................................9-17Table9-29DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04HSBoard.....................................................................................................9-17Table9-30TechnicalParametersoftheRAC-PIU-04HSBoard...............................9-18Table9-31InterfacePropertiesoftheRAC-PIU-04CE1-75Board...........................9-18Table9-32DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04CE1-75Board.....................................................................................................9-19Table9-33TechnicalParametersoftheRAC-PIU-04CE1-75Board........................9-19Table9-34InterfacePropertiesoftheRAC-PIU-04CE1-120Board.........................9-20Table9-35DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04CE1-120Board.....................................................................................................9-20VIIISJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
TablesTable9-36TechnicalParametersoftheRAC-PIU-04CE1-120Board......................9-20Table9-37InterfacePropertiesoftheRAC-PIU-04UE1-75Board...........................9-21Table9-38DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04UE1-75Board.....................................................................................................9-21Table9-39TechnicalParametersoftheRAC-PIU-04UE1-75Board........................9-22Table9-40InterfacePropertiesoftheRAC-PIU-04UE1-120Board.........................9-23Table9-41DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04UE1-120Board.....................................................................................................9-23Table9-42TechnicalParametersoftheRAC-PIU-04UE1-120Board......................9-23Table9-43InterfacePropertiesoftheRAC-PIU-16CE1Board................................9-24Table9-44DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-16CE1Board.....................................................................................................9-25Table9-45TechnicalParametersoftheRAC-PIU-16CE1Board.............................9-25Table9-46InterfacePropertiesoftheRAC-PIU-16CE1-CESBoard.......................9-26Table9-47DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-16CE1-CESBoard.....................................................................................................9-26Table9-48TechnicalParametersoftheRAC-PIU-16CE1-CESBoard....................9-26Table9-49InterfacePropertiesoftheRAC-PIU-01P12-SFPBoard........................9-27Table9-50DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-01P12-SFPBoard.....................................................................................................9-27Table9-51TechnicalParametersoftheRAC-PIU-01P12-SFPBoard.....................9-27Table9-52InterfacePropertiesoftheRAC-PIU-02P3-SFPBoard..........................9-28Table9-53DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-02P3-SFPBoard.....................................................................................................9-29Table9-54TechnicalParametersoftheRAC-PIU-02P3-SFPBoard.......................9-29Table9-55InterfacePropertiesoftheRAC-PIU-04P3-SFPBoard..........................9-30Table9-56DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04P3-SFPBoard.....................................................................................................9-30Table9-57TechnicalParametersoftheRAC-PIU-04P3-SFPBoard.......................9-30Table9-58InterfacePropertiesoftheRAC-PIU-02CP3-SFPBoard........................9-31Table9-59DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-02CP3-SFPBoard.....................................................................................................9-31Table9-60TechnicalParametersoftheRAC-PIU-02CP3-SFPBoard.....................9-32Table9-61InterfacePropertiesoftheRAC-PIU-04CP3-SFPBoard........................9-33Table9-62DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04CP3-SFPBoard.....................................................................................................9-33Table9-63TechnicalParametersoftheRAC-PIU-04CP3-SFPBoard.....................9-33IXSJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionTable9-64InterfacePropertiesoftheRAC-PIU-04GE-SFPBoard..........................9-34Table9-65DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-04GE-SFPBoard.....................................................................................................9-34Table9-66TechnicalParametersoftheRAC-PIU-04GE-SFPBoard.......................9-35Table9-67InterfacePropertiesoftheRAC-PIU-08GE-SFPBoard..........................9-36Table9-68DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-08GE-SFPBoard.....................................................................................................9-36Table9-69TechnicalParametersoftheRAC-PIU-08GE-SFPBoard.......................9-36Table9-70GEElectricalInterfacePropertiesoftheRAC-PIU-05GE-4E1SFPBoard.....................................................................................................9-37Table9-71OpticalInterfacePropertiesoftheRAC-PIU-05GE-4E1SFPBoard.....................................................................................................9-37Table9-72DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-05GE-4E1SFPBoard.............................................................9-38Table9-73TechnicalParametersoftheRAC-PIU-05GE-4E1SFPBoard................9-38Table9-74GEElectricalInterfacePropertiesoftheRAC-PIU-09GE-8E1SFPBoard.....................................................................................................9-39Table9-75OpticalInterfacePropertiesoftheRAC-PIU-09GE-8E1SFPBoard.....................................................................................................9-39Table9-76DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-09GE-8E1SFPBoard.............................................................9-40Table9-77TechnicalParametersoftheRAC-PIU-09GE-8E1SFPBoard................9-40Table9-78GEElectricalInterfacePropertiesoftheRAC-PIU-08FE1GE-1SFPBoard.....................................................................................................9-41Table9-79OpticalInterfacePropertiesoftheRAC-PIU-08FE1GE-1SFPBoard.....................................................................................................9-41Table9-80DescriptionoftheIndicatorsonthePaneloftheRAC-PIU-08FE1GE-1SFPBoard...........................................................9-42Table9-81TechnicalParametersoftheRAC-PIU-08FE1GE-1SFPBoard..............9-42Table9-82GEElectricalInterfacePropertiesoftheRAC-DPIU-16GE-12SFP4EBoard.....................................................................................................9-43Table9-83OpticalInterfacePropertiesoftheRAC-DPIU-16GE-12SFP4EBoard.....................................................................................................9-44Table9-84DescriptionoftheIndicatorsonthePaneloftheRAC-DPIU-16GE-12SFP4EBoard.........................................................9-44Table9-85TechnicalParametersoftheRAC-DPIU-16GE-12SFP4EBoard............9-44Table9-86InterfacePropertiesoftheRAC-DPIU-01XGE-SFP+Board...................9-45Table9-87DescriptionoftheIndicatorsonthePaneloftheRAC-DPIU-01XGE-SFP+Board.............................................................9-46XSJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
TablesTable9-88TechnicalParametersoftheRAC-DPIU-01XGE-SFP+Board................9-46Table10-1CommonCablesoftheZXR10ZSRV2Router.....................................10-1Table10-2CoreWiresofaDCPowerCable..........................................................10-3Table10-3TechnicalParametersofanACPowerCable........................................10-3Table10-4CoreWiresofanAUXCable.................................................................10-4Table10-5CoreWiresofaConsoleCable.............................................................10-5Table10-6WiringSequenceoftheStraight-ThroughEthernetCable.....................10-7Table10-7WiringSequenceoftheCross-OverEthernetCable..............................10-7Table10-8TechnicalParametersoftheEthernetCable.........................................10-7Table10-9OpticalFiberConnectorPairingandUsage...........................................10-8Table10-10WiringSequenceoftheSHDSLCable...............................................10-10Table10-11TechnicalParametersoftheSHDSLCable........................................10-10Table10-12Synchronous/AsynchronousSerialCableTypes...............................10-13Table10-13E1TrunkCableConnections.............................................................10-13Table10-14CorrespondenceRelationshipsBetweentheEnd-APinsandEnd-B1Coresofthe75ΩUnbalancedCoaxialCable......................................10-14Table10-15CorrespondenceRelationshipsBetweentheEnd-APinsandEnd-B2Coresofthe75ΩUnbalancedCoaxialCable......................................10-15Table10-16CorrespondenceRelationshipsBetweentheEnd-APinsandEnd-B1Coresofthe120ΩBalancedTwisted-PairCable.................................10-16Table10-17CorrespondenceRelationshipsBetweentheEnd-APinsandEnd-B2Coresofthe120ΩBalancedTwisted-PairCable.................................10-17TableA-1BoardWeightandPowerConsumptionoftheZXR10ZSRV2SeriesRouters....................................................................................................A-1TableB-1SFPOpticalModules................................................................................B-1TableB-2OpticalModuleIndicatorDescriptions.......................................................B-1TableB-3155MSFPAttributes................................................................................B-1TableB-4622MSFPAttributes................................................................................B-2TableB-51.25GSFPAttributes...............................................................................B-2XISJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
TablesThispageintentionallyleftblank.XIISJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
GlossaryATM-AsynchronousTransferModeCLI-CommandLineInterfaceDCE-DataCircuit-terminatingEquipmentDSL-DigitalSubscriberLineDSLAM-DigitalSubscriberLineAccessMultiplexerDTE-DataT erminalEquipmentEFM-EthernetintheFirstMileETSI-EuropeanT elecommunicationsStandardsInstituteFR-FrameRelayHDLC-High-levelDataLinkControlIEC-InternationalElectrotechnicalCommissionIEEE-InstituteofElectricalandElectronicsEngineersIP-InternetProtocolITU-T-InternationalTelecommunicationUnion-T elecommunicationStandardizationSectorML-PPP-Multilink-PointtoPointProtocolODF-OpticalDistributionFramePOS-PacketOverSONET/SDHXIIISJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential
ZXR10ZSRV2HardwareDescriptionPPP-PointtoPointProtocolRSSI-ReceivedSignalStrengthIndicatorSDH-SynchronousDigitalHierarchySHDSL-Single-pairHighDigitalSubscriberLineSNMP-SimpleNetworkManagementProtocolSONET-SynchronousOpticalNetworkTDM-TimeDivisionMultiplexingXIVSJ-20150204153047-004|2015-03-30(R1.0)ZTEProprietaryandCondential