ZTE WF824 Outdoor CPE User Manual WF824

ZTE Corporation Outdoor CPE WF824

User Manual

Confidential and Proprietary Information of ZTE CORPORATION 1    WF824 Let’s go  Getting started with your device.                   ZTE CORPORATION   NO. 55, Hi-tech Road South, ShenZhen, P.R.China   Postcode: 518057
   WF824  Getting  Started Confidential and Proprietary Information of ZTE CORPORATION                                                                                      2 LEGAL INFORMATION  Copyright © 2016 ZTE CORPORATION.  All rights reserved.  No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any means,  electronic  or  mechanical,  including  photocopying  and  microfilm,  without  the  prior  written permission of ZTE Corporation.  The manual is published by ZTE Corporation. We reserve the right to make modifications on print errors or update specifications without prior notice.     Version No.      :    R1.0 Edition Time    :    2016.8.25
WF824 Getting Started  Confidential and Proprietary Information of ZTE CORPORATION                                                                                      3  Getting to Know Your Device Packing list Upon receiving the product, please unpack the product package carefully. Each product is shipped with the following items:   Outdoor CPE Products  Quantity ODU unit  1 Anchor ear  2 48V DC POE Power Adapter    1 Power cord  1 PC Ethernet Cable  1 If you find any of the items is missing, please contact our local distributor immediately.  Unpacking the Equipment All of the required material is provided in your Wireless access terminal Unit Installation Package. Please take the time to unpack the package and check the contents against the following list of material.    LED Indicators LED    Function  Description SYS  System Run Indicator  Fast Blinking – Device is rebooting Slow Blinking – Device is in normal operation       ETH  LAN port status  Solid Green –    LAN port is up Blinking Green – LAN data activity in progress RF (4LEDs)  RF Signal Strength Four Level Signal Strengths Indication. 1st Green LED: -123dBm <= RSRP < -118dBm 2nd Green LED: -118dBm <= RSRP < -114dBm 3rd Green LED: -114dBm <= RSRP < -105dBm 4th Green LED: -105dBm <= RSRP
   WF824  Getting  Started Confidential and Proprietary Information of ZTE CORPORATION                                                                                      4 Connection Scenario For outdoor CPE product, it is suggested that the CPE device be installed in a shaded area to avoid direct sun light exposure and prolong the device life.   To power on the device, the outdoor CPE use a 48V PoE integrated DC power supply adapter. The power adapter  can  operate  in  90-250V  AC  range  and therefore  can  be  used  in  different  countries.  Once  the device is powered up, the user should wait for about 2 minutes before the device becomes operational. For CPE with the SYS LED indicator, a slowly flashing light indicates the system has completed the startup procedure.     To  connect  your  PC,  LAN  switch,  or  other  type of  IP  device  to  the  CPE device,  the user should  use standard  CAT5  Ethernet  cable  and  connect  to  the  LAN  port.  Once  connected,  the  CPE  ETH  LED indicator should come on.           To obtain the best radio signal level and connection quality, the CPE antenna should be directed towards the  best serving cell. To  search for  the  best serving cell direction,  the user can rotate the CPE  slowly and/or tilt the CPE slightly to find the best signal direction. The CPE radio signal strength level can be observed from the RF LEDs mounted on the lower panel as shown below. The more LEDs on, the better the signal strength.
WF824 Getting Started  Confidential and Proprietary Information of ZTE CORPORATION                                                                                      5  Installing Outdoor Unit Mounting Bracket:       Header Connection:
   WF824  Getting  Started Confidential and Proprietary Information of ZTE CORPORATION                                                                                      6 Connecting to Your Device WF824 is a user-friendly wireless access terminal, and very easy to configure and setup. Subscribers can just connect the device to their computer or home switch/router and the device is ready to provide Internet Services. WEB Login It is a preferred to setup the CPE using a Web browser from a local PC connected to device LAN port. The user should ensure that the connected PC is able to acquired IP address via DHCP from the device.   After IP connectivity is established between the PC and CPE device the user may launch a Web browser and  specify http://10.1.1.1 in  the  address bar.  A window will pop up  requesting to  enter a  password. Input the default  user login password and  then  click the  “Log in” button.  After successful  log on,  the default  home  page  of  the  WEB  GUI  interface  will  appear.  Note  that  the  default  user  password  is “user123”. The admin password is protected and only available to the network operator.  Device Status   Once the user is logged in, the following window device status window will be prompted for viewing. It contains both the wireless link information, networking, and device information configured for the device.   The  wireless  info  provides  detailed  information  about  the  radio  connection  and  the  user  can  use  this information  to  determine  the  receiving  signal  strength  and  transmit  power  of  the  device. Click  the “Advanced” button to get more configuration options.
WF824 Getting Started  Confidential and Proprietary Information of ZTE CORPORATION                                                                                      7  LAN Configuration  The LAN setting allows user to specify the DHCP server setting for the LAN devices, including the pool address, IP and MAC binging, and whether DHCP server should be enabled.   User  is  advised  to  leave  the  default  setting  unchanged  for  quick  configuration  and  smooth  device operation.   UPnP Setting
   WF824  Getting  Started Confidential and Proprietary Information of ZTE CORPORATION                                                                                      8 Forwards: Configure Port forwarding for UPnP. Click the trash sign to delete individual entry. UPnP Service: Allows applications to automatically identification port forwarding. Maintenance  Firmware Upgrade over HTTP:   Click on the Browser button to select the firmware file to be uploaded to the device. Click the Upgrade button to begin the upgrade process. Upgrade must not be interrupted. Load Factory Defaults: Once the upgraded is complete, the factory setting will be restored to the CPE device. User may need to reconfigure the device in order to get the device operational. Device Reset In case the user forgets the login password, user can also contact the operator.
WF824 Getting Started  Confidential and Proprietary Information of ZTE CORPORATION                                                                                      9  Warning and Notice To the Owner • Some  electronic  devices  are  susceptible  to  electromagnetic  interference  sent  by  your  device  if inadequately shielded, such as the electronic system of vehicles. Please consult the manufacturer of your device before using if necessary. • Operating your device may interfere with medical devices like hearing aids and pacemakers. Please always keep them more than 20 centimeters away from such medical devices when they are turned on. Turn your device off if necessary. Consult a physician or the manufacturer of the medical device before using your device. • Be  aware  of  the  usage  limitation  when  using  your  device  at  places  such  as  oil  warehouses  or chemical factories, where there are explosive gases or explosive products being processed. Turn off your device if required. • The use of electronic transmitting devices is forbidden in aircrafts, at petrol stations and in hospitals. Please observe and obey all warning signs and switch off your device in these conditions. • Do  not  touch  the  inner  antenna  area  if  not  necessary.  Otherwise  it  will  affect  your  device’s performance. • Store your device out of the reach of little children. Your device may cause injury if used as a toy. • Do not touch the metallic parts of your device so as to avoid a burn, when your device is working. Using Your Device • Please use original accessories or accessories that are authorized. Using any unauthorized accessories may  affect  your  device’s  performance,  and  violate  related  national  regulations  about  telecom terminals. • Avoid  using  your  device  near  or  inside  metallic  structures  or  establishments  that  can  emit electromagnetic waves. Otherwise it may influence signal reception. • Your device is not waterproof. Please keep it dry and store in a shady and cool place. • Do not use your device immediately after a sudden temperature change. In such case, it will produce dew inside and outside your device, so don’t use it until it becomes dry. • Handle your device carefully. Do not drop, bend or strike it. Otherwise your device will be damaged. • No dismantling by non-professionals and only qualified technicians can undertake repair work. • Operating temperature range of -40 ~ +60 and humidity range of 5% ~ 95% are recommended.
   WF824  Getting  Started Confidential and Proprietary Information of ZTE CORPORATION                                                                                     10Limited Warranty • This warranty does not apply to defects or errors in the Product caused by: i. Reasonable abrasion. ii. End  User’s  failure  to  follow  ZTE’s  installation,  operation  or  maintenance  instructions  or procedures. iii. End User’s mishandling, misuse, negligence, or improper installation, disassembly, storage, servicing or operation of the Product. iv. Modifications or repairs not made by ZTE or a ZTE-certified individual. v. Power failures, surges, fire, flood, accidents, actions of third parties or other events outside ZTE’s reasonable control. vi. Usage of third-party device, or usage in conjunction with third-party products provided that such defects are due to the combined usage. vii. Any other cause beyond the range of normal usage intended for the Product. End User shall have no right to reject or return the Product, or receive a refund for the Product from ZTE under the above-mentioned situations. • This warranty is End User’s sole remedy and ZTE’s sole liability for defective or nonconforming items, and is in lieu of all other warranties, expressed, implied or statutory, including but not limited to the implied  warranties of  merchantability and  fitness for  a  particular purpose, unless otherwise required under the mandatory provisions of the law. Limitation of Liability • ZTE shall not be liable for any loss of profits or indirect, special, incidental or consequential damages resulting from or arising out of or in connection with using of this product, whether or not ZTE had been  advised,  knew  or  should  have  known  of  the  possibility of  such damages,  including,  but  not limited to lost profits, interruption of business, cost of capital, cost of substitute facilities or product, or any downtime cost. FAQ and Troubleshooting Problem  Suggested Solution My  PC  cannot  connect  to the CPE.   • Re-plug the PC Ethernet cable and check if the PC LAN connection is up or showing activity.   • Check if the PoE power adapter LED is on. If it is not, check the power cord and make sure it is connected properly. Also verify that the AC power supply is available.   • If the PC LAN shows no activity and PoE adapter LED is off but the power cord and ETH cable are connected properly and there is AC  supply,  then  it  is  likely  the  PoE  adapter  is  damaged.  Please
WF824 Getting Started  Confidential and Proprietary Information of ZTE CORPORATION                                                                                     11 contact distributor to obtain replacement part.   My  PC  cannot  acquire  IP from the CPE. • First check if the Network card is up and working properly. Then check the PC Network card configuration and make sure the DHCP is enabled. • To  release  and  renew  the  correct  IP  address,  please  unplug  the Ethernet cable from PC and wait for about 5 seconds, then connect it again.   • If the problem persists, please contact the operator or distributor for further diagnosis. My CPE networking is not working properly.    • You  may  want  to  check  if  the  wireless  connection  is  up  and running  properly.  You  can  do  this  by  login  the  WEB  GUI  and check the Interface Info page. • You may want to perform a factory reset and see if the problem is being corrected. You can do this by log into the WEB GUI using “user”  password  and  perform  restore  the  unit  to  default  factory setting.   • If the problem cannot be corrected by factory reset, please contact the operator or distributor. I forgot the login password and like to reset the unit to factory default.    • User can also contact the operator.  Federal Communication Commission Interference Statement  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant  to  Part  15  of  the  FCC  Rules.    These  limits  are  designed  to  provide  reasonable protection  against  harmful  interference  in  a  residential  installation.  This  equipment  generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,  may  cause harmful  interference to  radio communications.    However,  there  is  no guarantee  that  interference  will  not  occur  in  a  particular  installation.    If  this  equipment  does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:  Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver.
   WF824  Getting  Started Confidential and Proprietary Information of ZTE CORPORATION                                                                                     12Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.  FCC Caution:  Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This  transmitter must not be co-located or  operating in conjunction with any other antenna or transmitter.  Radiation Exposure Statement: This  equipment  complies  with  FCC  radiation  exposure  limits  set  forth  for  an  uncontrolled environment.  This  equipment  should  be  installed  and  operated  with  minimum  distance  20cm between the radiator & your body.  For more assistance, please: •  Send E-mail to mobile@zte.com.cn •  Visit http://www.ztedevice.com •  Call Service Hotline: +86–755–26779999(May generate long distance call charges) •  US Customer Support: +1–877–387-6771

Navigation menu