AP 7161
ACCESS POINT
INSTALLATION GUIDE
2
AP 7161 Access Point Installation Guide
AP 7161 Access Point Installation Guide
Motorola Solutions reserves the right to make changes to any product to improve reliability, function, or design.
Motorola Solutions does not assume any product liability arising out of, or in connection with, the application or
use of any product, circuit, or application described herein.
No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent,
covering or relating to any combination, system, apparatus, machine, material, method, or process in which
Motorola Solutions products might be used. An implied license exists only for equipment, circuits, and
subsystems contained in Motorola Solutions products.
Service Information
If you have a problem using the equipment, contact your facility’s Technical or Systems Support. If there is a
problem with the equipment, they will contact Motorola Solutions Support at: http://motorolasolutions.com/support.
4
AP 7161 Access Point Installation Guide
Introduction.................................................................................................................................................................................... 5
Document Conventions.................................................................................................................................................................. 6
AP 7161 Hardware.......................................................................................................................................................................... 7
AP 7161 Antenna Assessories................................................................................................................................................. 7
AP 7161 2.4 GHz Antennas ............................................................................................................................................... 7
AP 7161 4.9 GHz and 5 GHz Antennas ............................................................................................................................... 8
AP 7161 Multi Band Antennas .......................................................................................................................................... 8
Outdoor PoE Hardware and Mounting Accessories................................................................................................................. 9
AP 7161 Mounting Accessories............................................................................................................................................... 9
AP 7161 Weatherized Ethernet Accessory............................................................................................................................... 9
Package Contents......................................................................................................................................................................... 10
Hardware Installation Guidelines................................................................................................................................................. 11
Precautions................................................................................................................................................................................... 11
Warnings...................................................................................................................................................................................... 12
Access Point Placement............................................................................................................................................................... 13
AP 7161 Hardware Overview........................................................................................................................................................ 14
AP 7161 Ports and Connections.................................................................................................................................................... 14
AP 7161 Antenna Connectors................................................................................................................................................ 14
AP 7161 Console, GE1/POE and GE2 Ports............................................................................................................................. 16
AP 7161 Grounding Screw..................................................................................................................................................... 17
AP 7161 Factory Reset Hardware Button............................................................................................................................... 18
LED Indicators............................................................................................................................................................................... 18
Two Radio LEDs..................................................................................................................................................................... 19
Three Radio LEDs................................................................................................................................................................... 20
AP 7161 Hardware Mounting and Installation............................................................................................................................. 21
Mounting Bracket Kit............................................................................................................................................................. 21
Extension Arm Kit................................................................................................................................................................... 22
Pole Mounted Installations.................................................................................................................................................... 24
Vertical Pole Mount............................................................................................................................................................... 25
Wall Mounted Installations................................................................................................................................................... 28
AP 7161 Power Options Using Power over Ethernet.................................................................................................................... 31
Basic AP 7161 Configuration........................................................................................................................................................ 32
Antenna Type Configuration...................................................................................................................................................32
Automatic Channel Select Override....................................................................................................................................... 32
Specifications............................................................................................................................................................................... 33
Basic Troubleshooting.................................................................................................................................................................. 36
Regulatory Compliance................................................................................................................................................................ 37
Motorola Solutions Support Center.............................................................................................................................................. 49
AP 7161 Series RoHS Compliance................................................................................................................................................ 50
AP 7161 Access Point Installation Guide
Introduction
Perfect for extending network coverage to outside areas, the AP 7161 brings the latest 802.11n 3x3 Multiple Input
Multiple Output (MIMO) tri-radio design together with rugged outdoor performance. True perimeter security is
provided using either a dedicated dual band sensor or software mode for both 2.4GHz and 5GHz bands to deliver
24x7 rogue detection and termination. The AP 7161 is optimized with Motorola Solutions WiNG 5 intelligence,
extending QoS, security, and mobility services to the access point to support better capacity and performance. The
AP 7161 is ideal for industrial, enterprise campus, video surveillance, public safety, and smartgrid utility
deployments to extend to the outdoors.
Deployments can be managed using the Motorola Solutions WiNG 5 architecture. The WiNG 5 architecture is a
solution designed for 802.11n networking. It leverages the best aspects of independent and dependent
architectures to create a smart network that meets the connectivity, quality, and security needs of each user and
their applications based on the availability of network resources, including wired networks. WiNG 5 is a Third
Generation WLAN solution which incorporates the best of both the first generation Autonomous Access Point
WLAN and the second generation Centralized Controller Based WLAN.
The control plane is now distributed between the access points and the controllers. The network administrator
has the flexibility of directing the data plane either being forwarded directly from the access points, or via the
controllers. By distributing intelligence and control between the wireless controllers and APs, the WiNG 5
network can route directly via the best path, as determined by factors including the user, the location, the
application, and the available wireless and wired resources.
Once adopted by a Motorola Solutions RFS4000, RFS6000, or RFS7000 series controller, the AP 7161 is managed
as an Adaptive AP running the WiNG 5 network management protocol. WiNG 5 networks extend the current
differentiation that Adaptive APs offered to the next level by now having the services and security available at
every point in the network. The traffic flow is optimized to prevent wired congestion, as well as wireless
congestion. Traffic flows dynamically, based on user and application, and finds alternate routes to work around
any possible network choke points. Mixed-media application optimization is the hallmark of WiNG 5 networks.
Extending the indoor network to the outdoors increases the need to guard against unwanted intruders and
attackers, and monitor network performance and availability. In addition to industry standard security for clients
and radio backhaul, the AP 7161 provides true perimeter security using either a dedicated dual band sensor or
software mode in the 2.4GHz and 5Ghz bands. Concurrent around-the-clock dual band Network Assurance sensing
and wireless traffic is provided together with spectrum analysis, eliminating the need for separate devices.
An access point can function as a Wireless Intrusion Protection System (WIPS) sensor and upload sensor mode
operation information to a dedicated WIPS server. WIPS protects your wireless network, mobile devices, and
traffic from attacks and unauthorized access. WIPS provides tools for standards compliance and around-the-clock
802.11a/b/g wireless network security in a distributed environment. WIPS allows administrators to identify and
accurately locate attacks, rogue devices, and network vulnerabilities in real time and permits both a wired and
wireless lockdown of wireless device connections upon acknowledgement of a threat.
6
AP 7161 Access Point Installation Guide
Capacity in video surveillance solutions is critical to the performance of many networks designed to monitor and
provide safety. To assist with the deployment of video surveillance networks where the camera application
resides, the AP 7161 offers band unlocked radio flexibility. The user can choose between 2.4Ghz, 5Ghz and 4.9Ghz
bands for the radio type. The AP 7161 supports 3x3 MIMO technology, reaching a maximum data rate of 300 Mbps
to maintain high performance and better quality of transmission.
The AP 7161 is designed to optimize network availability through preemptive intelligence which dynamically
senses weak or failing signals, securely moves mobile users to alternate APs, and boosts signal power to
automatically fill RF holes and ensure uninterrupted mobile user access.
The AP 7161 band unlocked radios allow flexibility and deployment options for the public safety market. The
powerful radio increases coverage, performance, and obstruction penetration for outdoor use. Receiver sensitivity
is increased proportionally so users have an increased ability to maintain high performance access for mobility
and client devices in the network.
For the latest version of this guide go to: http://supportcentral.motorola.com.
Document Conventions
The following graphical alerts are used in this document to indicate notable situations:
NOTE
Tips, hints, or special requirements that you should take note of.
CAUTION Care is required. Disregarding a caution can result in data loss or equipment
malfunction.
WARNING! Indicates a condition or procedure that could result in personal injury or equipment
damage.
AP 7161 Access Point Installation Guide
AP 7161 Hardware
There are currently four AP 7161 access point models:
Model Part Number
Description
AP-7161-66040-US
AP 7161 OUTDOOR DUAL RADIO 802.11N US
AP-7161-66040-WR
AP 7161 OUTDOOR DUAL RADIO 802.11N INTL
AP-7161-66S40-US
AP 7161 OUTDOOR DUAL RADIO 802.11N AP WITH SENSOR US
AP-7161-66S40-WR
AP 7161 OUTDOOR DUAL RADIO 802.11N WITH SENSOR INTL
AP 7161 Antenna Accessories
The AP 7161 antenna suite includes the following optional antenna accessories. The antennas do not ship wth the
AP 7161 models listed in the table above and must be ordered separately.
AP 7161 2.4 GHZ Antennas
Part Number
Band
Gain
Height
(inches)
Antenna Description
ML-2499-HPA8-01
2.4
19.5
Outdoor rated
Type: dipole
Gain: 8dBi@2.4GHz
Connector: N-male
ML-2499-HPA4-01
2.4
9.0
Outdoor rated
Type: dipole
Gain: 4dBi@2.4GHz
Connector: N-male
RAN4054A
2.4
21
Outdoor rated
Type: dipole
Gain: 8dBi@2.4GHz
Connector: N-male
8
AP 7161 Access Point Installation Guide
AP 7161 4.9 GHz and 5 GHz Antennas
Part Number
Band
Height
(inches)
Gain
Description
ML-5299-HPA10-01
4.9-5.8
10
19.5
Indoor and Outdoor rated
Type: dipole
Gain: 10dBi@4.9GHz
Connector: N-male
ML-5299-HPA5-01
5.2-5.8
6.75
Indoor and Outdoor rated
Type: dipole
Gain: 5dBi@5.0GHz
Connector: N-male
ML-5299-FHPA6-01
4.9-5.8
11
Outdoor rated
Type: dipole
Gain: 8dBi@4.9-5.8GHz
Connector: N-male
AP 7161 Multi Band Antenna
Part Number
Band
Gain
Height
(inches)
11
Description
ML-2452-HPAG5A8-01
2.4-5.8
4.5/7.5
Outdoor rated
Type: dipole
Gain: 4.5dBi@2.4GHz,
7.5dBi@5GHz, 5.5dBi@4.9GHz
Connector: N-male
MT-465019/NVD
4.9-5.8
19
Outdoor only rated
Type: panel
ML-2452-PNL9M3-036
2.4-5.8
8/10.7
Indoor and Outdoor rated
Type: panel
ML-2452-VMM3M3-036
2.4-5.8
6 peak
Outdoor rated
Type: vmm
PDM24516-MT1
2.4-5.8
8.3/10.1
Indoor and Outdoor rated
Type: patch
AP 7161 Access Point Installation Guide
Outdoor PoE Hardware and Mounting Accessories
The AP 7161 is a Power over Ethernet (PoE) device. When deployed, the use of an outdoor rated PoE power supply
and mounting bracket may be required. The recommended Motorola Solutions PoE accessories are listed in the
following table. For more information, see AP 7161 Power Options Using Power over Ethernet (PoE) on page 31.
Part Number
Description
AP-PSBIAS-7161-US
Outdoor IP66 802.3AT gigabit Ethernet power injector, 100-240 VAC US
AP-PSBIAS-7161-WW
Outdoor IP66 802.3AT gigabit Ethernet power injector, 100-240 VAC
International
KT-153143-01
Outdoor PoE mounting kit
AP 7161 Mounting Accessories
The AP 7161 has a flexible three piece mounting kit, together with an optional standoff extension arm for pole
mounting. For more information, see AP 7161 Hardware Mounting and Installation on page 21.
Part Number
Description
KT-147407-01
AP 7161 mounting hardware kit
KT-150173-01
AP 7161 12 inch extension arm for mounting kit
AP 7161 Weatherized Ethernet Accessory
One RJ45 weatherized connector plug is included with each AP 7161 access point. If additional plugs are required,
they can be ordered using the part number listed in the following table:
Part Number
KT-153676-01
Description
AP 7161 RJ45 weatherized Ethernet plug
10
AP 7161 Access Point Installation Guide
Package Contents
Carefully remove all protective packing material from around the AP 7161 access point and save the container for
later storage and shipping. Refer to AP 7161 Hardware on page 7 when verifying that all AP 7161 hardware has
been received. Record the serial numbers on the shipping cartons and AP 7161 access points for warranty claims
and reference during software download procedures.
Each AP 7161 model number (see AP 7161 Hardware on page 7) includes the following parts:
• AP 7161 access point
• Weatherproof RJ45 plug kit
• AP 7161 Access Point Installation Guide (this document)
The following items are not included with the AP 7161 access point models but can be ordered from Motorola
Solutions:
• Antenna(s)
• Mounting brackets/kits
• PoE power supply and accessories
• RFS controllers (if required)
The following items are not provided by Motorola Solutions and can be sourced from local hardware suppliers,
partners, or distributors:
• Lightning protection unit
• Cat5E cable to connect power source
• Band clamps, lag bolts, or U-bolts
• Grounding wire
When opening the shipping cartons, inspect the equipment for damaged or missing parts (see AP 7161 Hardware
on page 7). If you find any damaged or missing equipment, contact your distributor, partner, or Motorola Solutions
Support immediately.
For items that are not provided by Motorola Solutions, contact your local hardware suppliers.
AP 7161 Access Point Installation Guide
11
Hardware Installation Guidelines
CAUTION All device wiring must comply with the National Electric Code (NEC) or regulations
and procedures defined by the regulatory bodies of the country or region where the
devices are being deployed. All local building and structure codes must be
observed.
WARNING! Strictly observe the following safety precautions and warnings when installing an AP
7161 access point.
Precautions
Before installing an AP 7161 model access point, verify the following grounding and lightning protection notes:
• The installation professional should be familiar with all grounding requirements and regional codes and ensure
that the access point and mounting asset are properly grounded. The grounding cable for an AP 7161 must be
at a minimum a #10 gauge wire cross section. The cable can be attached to the unit using one of the following
methods:
•
Loosen the grounding screw, insert the grounding cable into the hole below it, and tighten the screw.
•
Loosen the grounding screw, wind the grounding cable around it, and tighten the screw.
•
Attach a ring lug to the grounding cable and secure it to the unit using the grounding screw.
• To properly attach the grounding cable to the access point, refer to AP 7161 Grounding Screw on page 17.
• For Ethernet and lightning protection, it is recommended that a commercially available off-the-shelf Lightning
Protection Unit (LPU) be used on all shielded CAT5E Ethernet connections. The LPU should be rated for outdoor
use.
•
For the best possible protection, each access point requires an LPU be installed adjacent to the access point.
If there is a LAN connection to an indoor network, a second LPU is required at the cable entry point to the
building.
CAUTION Lightning damage is not covered under the conditions of a standard Motorola
Solutions product warranty. When installed correctly, Lightning Protection
Units (LPUs) provide the best protection from the harmful effects of lightning.
Observe all regional and national codes that apply for lightning protection.
• Verify that the deployment environment has a continuous temperature range compatible with the operating
temperature range of the device.
12
AP 7161 Access Point Installation Guide
Warnings
• Read all installation instructions and site survey reports, and verify correct equipment installation before
connecting the access point to its power source.
• Remove jewelry and watches before installing this equipment.
• Verify that the unit is grounded before connecting it to the power source.
• Verify that any device connected to this unit is properly wired and grounded.
• Connect all power cords to a properly wired and grounded electrical circuit. Verify that the electrical circuits
have appropriate overload protection.
• Attach only approved power cords to the device.
• Verify that the power connector and socket are accessible at all times during the operation of the equipment.
• Do not hold any component containing a radio such that it is very close to or touching any exposed parts of the
body, especially the face or eyes, while transmitting.
• Do not work with power circuits in dimly lit spaces.
• Do not install this equipment or work with its power circuits during thunderstorms or other weather conditions
that could cause a power surge.
• Verify there is adequate ventilation around the device, and that ambient temperatures meet equipment
operation specifications.
• Avoid contact with overhead power lines.
• Take precautions to avoid injury from falling tools and equipment. Crews should wear hard hats in and around
the installation work site.
• Be aware of vehicular traffic in and around the installation work site.
• Do not operate a portable transmitter near unshielded blasting caps or in an environment where explosives are
present unless the transmitter is especially certified for such use.
• Refer to your site survey and network analysis reports to determine specific requirements for each deployment.
• Assign installation responsibility to the appropriate personnel.
• Identify and document where all installed components are located.
• Identify and prepare Ethernet and console port connections.
• Verify that cable lengths are within the maximum allowable distances for optimal signal transmission.
CAUTION The maximum length allowed for PoE cables is 100 meters.
AP 7161 Access Point Installation Guide
13
Access Point Placement
Observe the following recommended guidelines to help ensure a successful network deployment:
• Identify all pieces of the mounting bracket and mounting extension arm hardware and ancillary hardware (see
AP 7161 Hardware on page 7).
• Mount the device with the black gore vent down.
• Mounting height for network devices should not exceed 30 to 35 feet. Mounting height should vary to
accommodate the topography of the deployment area, foliage, and other obstructions.
• When mounting an access point, keep the antennas away from any metal obstructions. Utilize the extension
arm (KT-150173-01) if neccesary.
• Line of Sight (LoS) guidelines should be given special consideration whenever devices will not be installed in a
straight line, such as deploying devices on alternating sides of a roadway.
14
AP 7161 Access Point Installation Guide
AP 7161 Hardware Overview
AP 7161 models can be purchased in a two or three radio configuration (see AP 7161 Hardware on page 7). Each
model has two band unlocked radios that can operate across the 2.4GHz, 4.9GHz, and 5GHz bands, subject to
country regulatory approval and outdoor/band use.
An AP 7161 must be installed by trained professionals familiar with RF planning and regulatory limits defined by
the regulatory bodies of the country where the devices are being deployed. All common precautions for grounding
and Electrostatic Discharge (ESD) protection should be observed during deployment and installation. AP 7161
access points must be installed such that no harmful interference results from device operation.
AP 7161 Ports and Connections
The AP 7161 access point has the following port designations:
• Antenna ports R1-A, B and C, R2-A, B and C, and R3-A and B
• Console port
• GE1/POE - LAN port
• GE2 - WAN port
The following sections describe the ports and connections for the AP 7161.
AP 7161 Antenna Connectors
AP 7161 two radio models (AP-7161-66040-US and AP-7161-66040-WR) are configured with six N type connectors
to support two active WLAN data radios.
When mounting antennas to ports R1-A, R1-B, and R1-C, ensure that you have selected the appropriate band for
the configured radio that uses ports R1-A, R1-B, and R1-C. In this instance, R1 ports relate to the software
configured radio 1 settings.
AP 7161 Access Point Installation Guide
15
When mounting antennas to connectors marked R2-A, R2-B and R2-C, these antenna ports relate to the software
settings of radio 2. Care must be taken to provide the correct antenna for the operating band of each port.
AP 7161 three radio models (AP-7161-66S40-US and AP-7161-66S40-WR) are configured with eight N type
connectors to support two active WLAN data radios and a dedicated sensor radio as the third.
As with two radio models, the rules for ports R1-A, R1-B and R1-C and R2-A, R2-B and R2-C apply. R3-A and R3-B
are the ports reserved for the sensor radio, and an appropriate multi band antenna should be mounted to the unit
for sensor operation.
NOTE
The sensor radio does not function as a WLAN data radio.
WARNING!
Antenna ports where no antenna is mounted must be properly terminated using an
approved IP67 terminator.
16
AP 7161 Access Point Installation Guide
AP 7161 Console, GE1/POE and GE2 Ports
The AP 7161 has Ethernet ports for external console, GE1/POE, and GE2 connections.To gain access to the ports
you will need to remove the protective caps.
The Ethernet cable from the PoE device (if used) connects to the GE1/POE port on the unit.
AP 7161 Access Point Installation Guide
17
The GE2 port on the unit can be used if a second data connection for an external device (e.g. surveillance camera)
is required. Ensure the GE2 WAN port has been configured to permit an attached external device during the
configuration process.
When making connections using these ports, a properly rated RJ45 connector is required. One weatherproof RJ45
plug kit is provided with each access point. When connecting cables to the AP 7161 Ethernet ports, follow the
instructions in the connector packaging and tighten the connectors to create a weatherproof seal. Shielded cables
are required.
AP 7161 Grounding Screw
The grounding screw is located to the right of the GE1/POE port and above the GND symbol.
WARNING! The grounding cable for an AP 7161 must be at a minimum a #10 gauge wire cross
section.
The grounding cable can be attached to the unit using one of three recommended methods. Using an 8mm socket
and driver:
• Loosen the grounding screw and insert the grounding cable into the hole below it. Tighten the grounding screw
to 30 inch pounds (lbf-in).
• Loosen the grounding screw and wind the grounding cable around the screw. Tighten the grounding screw to 30
inch pounds (lbf-in).
• Attach a ring lug to the grounding cable and remove the grounding screw to attach the ring lug to the access
point. Secure it to the unit by reinserting the grounding screw. Tighten the grounding screw to 30 inch pounds
(lbf-in).
18
AP 7161 Access Point Installation Guide
AP 7161 Factory Reset Hardware Button
An AP 7161 can be physically reset using the factory reset hardware button. The button is located inside the reset
port on the bottom of the unit.
NOTE
This option is not supported by all AP 7161 software releases. Refer to the release
notes for the appropriate software.
The reset button is only enabled for a ten second interval as the unit boots up. It can be accessed by removing the
cover screw using a ratchet driver and a #2 Phillips head adapter. Push the button to reset the access point.
Confirm that the reset cycle was completed and replace the cover screw.
To perform an external hardware reset and restore the access point default settings:
1.
Using a #2 phillips screwdriver, remove the cover screw from the external reset port.
2.
Gently press and hold the reset button.
3.
If any of LEDs 2 through 6 are active, it indicates that the unit has booted successfully and the operational
software is running.
LED Indicators
The AP 7161 access point has six LEDs on the top of the access point housing.
The access point utilizes two different colored lights below each LED. Only one light displays within an LED at any
given time. Every light within each LED is exercised during startup to allow the user to see if an LED is not
functioning. The LEDs turn on and off while rotating in a circular pattern. Since two LEDs feed each light pipe, the
pattern is from left to right (LEDs 1 through 6), then right to left (LEDs 6 through 1).
AP 7161 Access Point Installation Guide
19
The top housing LEDs have the following display patterns and functionality:
Two Radio LEDs
A two radio model access point (P/N AP-7161-66040-US and AP-7161-66040-WR) has the following unique LED
behavior:
LED 1
(Sensor)
Not Used
LED 2
(2.4 GHz)
LED 3
(5 GHz)
Blinking
Emerald
indicates
802.11b/g/n
activity.
Solid Emerald
indicates a radio
is present but
not configured.
LED 4
(GE2/WAN)
LED 5
(GE1/LAN)
Blinking Amber
indicates
802.11a/n
activity.
LED Off
indicates the
port is not
connected.
LED Off
indicates the
port is not
connected.
Solid Amber
indicates a radio
is present but
not configured.
Blinking Green
indicates
normal
operation.
Blinking Green
indicates
normal
operation.
Rapidly blinking
Yellow
indicates a port
error.
Rapidly blinking
Yellow
indicates a port
error.
LED 6
(System)
Solid Red
indicates
diagnostic mode.
Blinking Red at 1
second interval
indicates POST
failure.
Solid White
following
diagnostic
mode indicates
booting.
Blinking Red and
White at 1
second interval
indicates “no
adoption”.
Solid White
indicates normal
operation.
WARNING! If LED 6 remains blinking Red for longer than 10 minutes, cycle the power to the
unit. If the condition persists, contact the Motorola Solutions support center.
20
AP 7161 Access Point Installation Guide
Three Radio LEDs
A three radio model access point with sensor (P/N AP-7161-66S40-US and AP-7161-66S40-WR) has the following
unique LED behavior:
LED 1
(Sensor)
Blinking
Emerald and
Amber at 2
second interval
indicates a radio
is present but
not connected to
a server.
Solid Amber
indicates a radio
is present and
connected to a
server.
LED 2
(2.4 GHz)
Blinking
Emerald
indicates
802.11b/g/n
activity.
Solid Emerald
indicates a radio
is present but
not configured.
LED 3
(5 GHz)
LED 4
(GE2/WAN)
LED 5
(GE1/LAN)
Blinking Amber
indicates
802.11a/n
activity.
LED Off
indicates the
port is not
connected.
LED Off
indicates the
port is not
connected.
Solid Amber
indicates a radio
is present but
not configured.
Blinking Green
indicates
normal
operation.
Blinking Green
indicates
normal
operation.
Rapidly blinking
Yellow
indicates a port
error.
Rapidly blinking
Yellow
indicates a port
error.
LED 6
(System)
Solid Red
indicates
diagnostic mode.
Blinking Red at
1 second interval
indicates POST
failure.
Solid White
following
diagnostic
mode indicates
booting.
Blinking Red and
White at 1
second interval
indicates “no
adoption”.
Solid White
indicates normal
operation.
AP 7161 Access Point Installation Guide
21
AP 7161 Hardware Mounting and Installation
It is recommended to use the AP 7161 mounting bracket kit (KT-147407-01) for most deployments. When a
standoff distance is required for a pole mounted or wall mounted installation, use the extension arm kit
(KT-150173-01).
The following sections detail the installation procedure for deploying an AP 7161 access point:
Mounting Bracket Kit
The AP 7161 mounting bracket kit (KT-147407-01) includes the Access Point Bracket (left), Angle Adapter Bracket
(center), and Pole Mount Bracket (right) sections:
The Access Point Bracket and the Angle Adapter Bracket can be adjusted to rotate (plus or minus 15 degrees) and
tilt (up to 45 degrees) during installation to orient the unit for optimal positioning.
The following ancillary hardware to assemble the mounting bracket sections is included in the kit:
Description
Quantity
M6 serrated hex flanged screws
1/2 inch hex head nut
1/2 inch x 3/4 inch hex head bolt
22
AP 7161 Access Point Installation Guide
A torque wrench or ratchet with a 10mm adapter, or an adjustable wrench can be used to assemble the mounting
brackets. A finished assembly of the mounting bracket kit is shown below. Assembly during deployment may
differ to achieve the required angle and rotation for optimal positioning.
Extension Arm Kit
When mounting an AP 7161 on poles more than 3 inches in diameter, use the extension arm kit (KT-150173-01) to
provide a minimum standoff distance of twelve inches to avoid interference with the antennas.
AP 7161 Access Point Installation Guide
23
The extension arm kit can also be used in combination with the any of the brackets from the mounting bracket kit:
The following ancillary hardware to attach the extension arm to the mounting bracket kit sections is included in
the extension arm kit:
Description
Quantity
1/2 inch hex head nut
1/2 inch x 3/4 inch hex head bolt
24
AP 7161 Access Point Installation Guide
Pole Mounted Installations
The mounting hardware kit and extension arm can be used in various combinations to properly install the AP 7161
on a pole. For poles of up to 3 inches in diameter, attach the pole mount bracket of the mounting hardware kit at
the desired position on the pole using band clamps up to 3/4 inch width, or a 1/2 inch x 4 inch wide U-bolt and
nuts. For poles greater than 3 inches in diameter, attach the pole mount bracket using band clamps.
CAUTION Always mount the AP 7161 with the black gore vent facing down.
NOTE
The U-bolt and band clamps are not included in the mounting bracket kit.
NOTE
Use of the extension arm is recommended for installations on poles greater than 3
inches in diameter.
AP 7161 Access Point Installation Guide
25
Vertical Pole Mount
Use the following procedures for vertical pole mount installations. Use of the extension arm is recommended
when mounting the access point to poles greater than 3 inches is diameter.
For poles up to 3 inches in diameter when using a U-bolt:
1.
Thread the two inner nuts onto the U-bolt. Place the U-bolt at the desired mounting location.
2.
Place the pole mount bracket section on the U bolt. Adjust the inner nuts until the pole mount bracket section is
against the pole and the U-bolt can be secured tightly to the pole.
3.
Place the angle adapter bracket section on the U-bolt with the open slot connections on the bottom and align it
with the pole mount section.
4.
Put the two outer nuts on the U-bolt to attach the angle adapter bracket section to the pole mount bracket
section.
5.
Tighten all nuts to 300 inch pounds (lbf-in).
6.
Position the access point bracket section so that the bottom of the section with the straight (not bevel cut) side
is oriented toward the bottom side of the AP with the gore vent. Using a torque wrench or a ratchet and a
10mm socket, or an adjustable wrench, attach (but don’t tighten) the access point bracket section to the AP
7161 with the with four M6 hex flange screws.
7.
Insert two M6 hex flange screws into the bottom holes on the sides of the access point bracket section.
8.
With the access point positioned so that the gore vent is facing down, insert the two M6 hex flange screws in
the bottom holes on the sides of the access point bracket section into the open slot connections on the bottom
of the angle adapter bracket section.
9.
Rotate the access point bracket section upward and align the top holes on the sides with the top holes on the
angle adapter bracket section. Insert two M6 hex flange screws into the top holes on the angle adapter bracket
section.
10. Use
a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, to finish attaching the access
point bracket section to the angle adapter bracket section with the M6 hex flange screws in the open slot
26
AP 7161 Access Point Installation Guide
connections and the top holes on the angle adapter bracket section. Do not tighten the screws until all rotation
and tilt adjustments are complete.
11. To
adjust the position of the access point, rotate the access point bracket section (plus or minus 15 degrees)
and tilt the angle adapter bracket section (up to 45 degrees).
12. Tighten
all hex flange screws to 60 inch pounds (lbf-in).
For mounting with band clamps:
1.
Attach the pole mount bracket section at the desired mounting location using band clamps.
2.
With the angle adapter bracket section positioned so that the open connector slots are on the bottom, attach
the angle adapter bracket section to the pole mount bracket section using two 1/2 inch bolts and nuts. Tighten
the nuts to 300 inch pounds (lbf-in).
3.
Position the access point bracket section so that the bottom of the section with the straight (not bevel cut)
sides is oriented toward the bottom side of the AP with the gore vent. Using a torque wrench or a ratchet and a
10mm socket, or an adjustable wrench, attach (but don’t tighten) the access point bracket section to the AP
7161 with the with four M6 hex flange screws.
AP 7161 Access Point Installation Guide
27
4.
Insert two M6 hex flange screws into the bottom holes on the sides of the access point bracket section.
5.
With the access point positioned so that the gore vent is facing down, insert the two M6 hex flange screws in
the bottom holes on the sides of the access point bracket section into the open slot connections on the bottom
of the angle adapter bracket section.
6.
Rotate the access point bracket section upward and align the top holes on the sides with the top holes on the
angle adapter bracket section. Insert two M6 hex flange screws into the top holes on the angle adapter bracket
section.
7.
Use a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, to finish attaching the access
point bracket section to the angle adapter bracket section with the M6 hex flange screws in the open slot
connections and the top holes on the angle adapter bracket section. Do not tighten the screws until all rotation
and tilt adjustments are complete.
8.
To adjust the position of the access point, rotate the access point bracket section (plus or minus 15 degrees)
and tilt the angle adapter bracket section (up to 45 degrees).
9.
Tighten all hex flange screws to 60 inch pounds (lbf-in).
To use the extension arm with the mounting hardware kit:
1.
Attach the pole mount section at the desired mounting location using a U-bolt or band clamps.
2.
Complete the steps for assembling and positioning the mounting bracket sections for poles less than or greater
than 3 inches outlined above.
3.
Using a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, attach the extension arm to
the access point bracket section with four M6 hex flange screws. Tighten the hex flange screws to 60 inch
pounds (lbf-in).
4.
With the access point positioned so that the gore vent is facing down, attach the extension arm to the access
point with four M6 hex flange screws. Tighten the hex flange screws to 60 inch pounds (lbf-in).
28
AP 7161 Access Point Installation Guide
Examples for using the extension arm alone, or with the mounting bracket kit for a pole mount installation are
shown below:
Wall Mounted Installations
For wall mounted installations, use only the access point bracket and angle adjust bracket sections.
CAUTION Always mount the AP 7161 with the black gore vent facing down.
1.
NOTE
The U-bolt and band clamps are not included in the mounting bracket kit.
NOTE
The lag bolts are not included in the mounting bracket kit.
With the open slot connections facing down, attach the angle adjust bracket section at the desired mounting
location using four #10/32 lag bolts.
AP 7161 Access Point Installation Guide
2.
29
Using a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, attach (but don’t tighten) the
access point bracket section to the AP 7161 with four M6 hex flange screws and insert two M6 hex flange
screws into the bottom holes on the sides of the access point bracket section.
3.
With the access point positioned so that the gore vent is facing down, insert the two M6 hex flange screws in
the bottom holes on the sides of the access point bracket section into the open slot connections on the bottom
of the angle adapter bracket section.
4.
Rotate the access point bracket section upward and align the top holes on the sides with the top holes on the
angle adapter bracket section. Insert two M6 hex flange screws into the top holes on the angle adapter bracket
section.
5.
Use a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, to finish attaching the angle
adapter bracket section to the access point bracket section with the four M6 hex flange screws in the open slot
connections and the top holes on the angle adapter bracket section. Do not tighten the screws until all rotation
and tilt adjustments are complete
6.
To adjust the position of the access point, rotate the access point bracket section (plus or minus 15 degrees)
and tilt the angle adapter bracket section (up to 45 degrees).
7.
Tighten all hex flange screws to 60 inch pounds (lbf-in).
30
AP 7161 Access Point Installation Guide
To use only the extension arm:
1.
Using four #10/32 lag bolts, attach the extension arm at the desired mounting location.
2.
Using a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, attach the mounting extension
arm to the access point with four M6 hex flange screws. Tighten the hex flange screws to 60 inch pounds
(lbf-in).
To use the extension arm with the mounting hardware kit:
1.
With the open slot connections facing down, attach the angle adjust bracket section at the desired mounting
location using four #10/32 lag bolts.
2.
Complete the steps for assembling and positioning the angle adapter bracket and access point bracket sections
outlined above.
3.
With the access point positioned so that the gore vent is facing down, attach the extension arm to the access
point bracket section of the assembled mounting bracket already in position using four M6 hex flange screws.
Tighten the hex flange screws to 60 inch pounds (lbf-in).
4.
Using a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, attach the extension arm to
the access point with four M6 hex flange screws. Tighten the hex flange screws to 60 inch pounds (lbf-in).
AP 7161 Access Point Installation Guide
31
AP 7161 Power Options Using Power over Ethernet (PoE)
Power over Ethernet (PoE) is the power source for an AP 7161 access point. For optimal performance, an AP 7161
can be powered by the following Motorola Solutions injectors and RFS controllers that support 802.AT PoE.
For installations requiring an outdoor PoE injector, the following Motorola Solutions options are recommended:
• AP-PSBIAS-7161-US
• AP-PSBIAS-7161-WW
The AP-PSBIAS-7161 is a 1-Port 802.3at PoE Gigabit Ethernet injector. The injector is IP66 rated for outdoor
deployments when used with the weatherproof kit supplied.
There are two power cord options for the AP-PSBIAS-7161 models. The AP-PSBIAS-7161-US comes equipped with
a cable with a standard three prong power plug. This plug can be removed by the installer if required when
connecting to an AC source. The AP-PSBIAS-7161-WW comes equipped with a cable with open leads. Mounting
kits are not supplied (see Outdoor PoE Hardware and Mounting Accessories on page 9 for mounting kit part
numbers).
NOTE
Product installation and mounting instructions are provided with the outdoor power
injector. Refer to the AP-PSBIAS-7161 Install Guide.
If located within 100 meters of the controller and a PoE port is available, the AP 7161 access point can also be
connected directly to one of the following Motorola Solutions controllers:
• RFS4000
• RFS6000
• RFS7000
• NX9000
A standard CAT5E cable can be used to provide the connection to the AP 7161. The GE1/POE port on the AP 7161
is where the standard CAT5E cable will connect to the access point and use of the weatherproof RJ45 plug kit that
comes with the unit will maintain a weatherproof seal for outdoor installation at the ethernet port.
If a CAT5E cable is used to connect the access point to an RFS controller through a building egress, a suitable
lightning protection system should be considered. A professional installer should be consulted to identify an
appropriate system.
CAUTION When using controllers, the total power limits for the AP 7161 must be considered.
The two radio configuration draws less power than a three radio configuration. If
sufficient power is not available, the AP 7161 software will disable the third radio
and throttle back performance on all radio and Ethernet interfaces.
32
AP 7161 Access Point Installation Guide
Basic AP 7161 Configuration
For information on how use a Motorola Solutions RFS Series controller to manage an AP 7161 access point, refer
to the Motorola Solutions WiNG 5 Access Point System Reference Guide at http://supportcentral.motorola.com.
NOTE
Only a trained installation professional should configure the AP 7161.
For FCC and ETSI requirements, set the 2.4GHz radio gain to 8 dBi and set the
5GHz radio gain to 10 dBi.
The configuration steps below apply to radio1, radio2 and, optionally, radio3.
Access Point Location Configuration
Select outdoor or indoor placement of the transmitting antennas
ap71xx-XXXXXX (config-device-xx-xx-xx-xx-xx-xx-if-radio1)#placement outdoor
Note all indoor-only bands are disabled by the software
OR
ap71xx-XXXXXX (config-device-xx-xx-xx-xx-xx-xx-if-radio1)#placement indoor
Note all outdoor-only bands are disabled by the software
Antenna Configuration
For the AP 7161 to operate properly, the antenna type and antenna gain must be configured. Select
antenna type with following command:
ap71xx-XXXXXX (config-device-xx-xx-xx-xx-xx-xx-if-radio1)#service antenna-type ap7161-dipole
Select antenna gain with following command:
ap71xx-XXXXXX (config-device-xx-xx-xx-xx-xx-xx-if-radio1)# antenna-gain
These changes can also be made in the device profile configuration file.
Radio Channel and Power Configuration
ap71xx-XXXXXX (config-device-xx-xx-xx-xx-xx-xx-if-radio2)#channel
ap71xx-XXXXXX (config-device-xx-xx-xx-xx-xx-xx-if-radio2)#power
Only channels and power settings available in your regulatory domain and configuration will be allowed.
Automatic Channel Select Override
Under certain conditions (e.g. the presence of a 40 MHz channel intolerant client or a legacy device on the
extension channel), a radio which has been configured for 40 MHz channel operation may automatically select the
20 MHz channel. To override or restore automatic channel selection, use the following commands:
ap71xx-XXXXXX (config-device-xx-xx-xx-xx-xx-xx-if-radio1)#service ignore-ch-width-mgmt
ap71xx-XXXXXX (config-device-xx-xx-xx-xx-xx-xx-if-radio1)#no service ignore-ch-width-mgmt
This change can also be made in the device profile configuration file.
AP 7161 Access Point Installation Guide
Specifications
Hardware Specifications
Operating Voltage
36-57 VDC
Operating Current
Not to exceed 750 mA@48 VDC
Power In (PoE)
PoE support inbound power - 802.3AT on GE1/POE port
Ethernet Ports
2 Gigabit Ethernet ports
Dimensions (unit) mounted
28.1cm W x 21.8cx H x 9.4cm D (11.1" W x 8.6" H x 3.7" D)
Weight (Unit)
6.4 lbs / 2.9 Kg
Mounting
Adaptable mounting kit for pole and wall deployments with optional extension arm accessory
LED
6 top mounted weatherized LEDs with multifunction read
Uplink
2 Gigabit Ethernet Ports (GE1/POE, GE2) autosensing
Antenna Connectors
Outdoor rated N-Type connectors
Console Port
Outdoor rated RJ45 console port
Hardware Reset
External hardware reset button
Multi Band Security Sensor
Outdoor 24x7 Wireless Intrusion Prevention System (IPS)/Assurance Sensor
(SKU AP-7161-66S40-US, AP-7161-66S40-WR)
33
34
AP 7161 Access Point Installation Guide
Environmental Specifications
Operating Temperature
-40 to +70 degrees celsius
Storage Temperature
-40 to +85 degrees celsius
Operating Humidity
5-95 percent
Operating Altitude
8,000 feet
Storage Altitude
30,000 feet
Electrostatic Discharge
EN61000-4-2. Air +/-15kV, Contact +/-8kV
Enclosure
Outdoor IP67 rated, corrosion resistant enclosure
ASTM B117 salt, fog, and rust resistance
Wind Ratings
150 mph * (unit bracket measurement)
Operational Shock
IEC60721-3-4, Class 4M3, MIL STD 810F
Operational Vibration
IEC60721-3-4, Class 4M3
Radio Specifications
Network Standards
IEEE 802.11 a/b/g/n, 802.11e, 802.11i, WPA2, WMM, and WMM-UAPSD
Supported Data Rates
802.11b/g:1, 2, 5.5, 11, 6, 9, 12, 18, 24, 36, 48 and 54 Mbps
802.11a: 6, 9, 12, 18, 24, 36, 48 and 54 Mbps
802.11n: MCS 0-15 up to 300 Mbps
802.11n Support
3x3 MIMO with 2 spatial streams
20MHz and 40MHz channels supported
300Mbps data rates per radio
Packet aggregation (AMSDU,AMPDU)
Reduced interframe spacing
802.11 b/g/n
Operating frequency 2.4 - 2.483 GHz
Maximum EIRP 32 dBm*
802.11 a/n
Operating frequency 4.940 GHz - 4.990 GHz and 5.25 GHz - 5.35 GHz and 5.470 GHz - 5.825 GHz
Maximum EIRP 34 dBm*
*Maximum EIRP may vary based on local standards for the area of deployment.
AP 7161 Access Point Installation Guide
Networking and Software Specifications
Security
Stateful Firewall, IP filtering, NAT, 802.1X, 802.11i WPA2, WPA
24x7 Dual band sensor capabilities * (subject to software license keys and sensor radio SKU)
Advanced forensics
Connectivity troubleshooting
Wireless Intrusion Prevention
LiveRF
Quality of Service (QoS)
WMM, WMM-UAPSD, 802.1p, Diffserv and TOS
Routing
Layer 3 routing, 802.1q/p, DynDNS, DHCP server/client, BOOTP Client, PPPoE and LLDP
Approvals
Radio*
FCC Title 47, part 15, part 90; EN 301 489-17
EN 301 893, v1.5.1 DFS;EN 300 328
Industry Canada; China SRRC
Australia/New Zealand
Safety*
UL 60950-1, -22; CSA C22.2 No.60950-1-07, -22
CB-IEC 60950 -1, 22; EN 60950-1:2006+ A11:2009
RoHS/WEEE/CMM; CE
* For more country specific regulatory information, please contact Motorola Solutions or your
authorized partner.
Warranty
• One (1) year on AP 7161 hardware (accessories not included)
• (30) day on accessories
• (90) day on software
35
36
AP 7161 Access Point Installation Guide
Basic Troubleshooting
Basic troubleshooting recommendations for the AP 7161 access point are listed in the following table:
Indication
LEDs are not lit
Response
No power to device:
• Verify 802.3at compatible source is connected via PoE
• Verify AC source to PoE injector
• Unit was configured with LEDs disabled
No Ethernet connectivity to this unit
No Ethernet connectivity to this unit
No wireless connectivity to this unit
No wireless connectivity to this unit
AP 7161 Access Point Installation Guide
37
Regulatory Compliance
This device is approved under the Symbol Technologies, Inc. brand. Symbol Technologies, Inc. is a wholly owned
subsidiary of Motorola Solutions, Inc. (collectively “Motorola”).
All Motorola Solutions devices are designed to be compliant with rules and regulations in locations they are sold
and will be labeled as required. Any changes or modifications to Motorola Solutions equipment, not expressly
approved by Motorola Solutions, could void the user's authority to operate the equipment.
Local language translations are available at the following website:
http://supportcentral.motorola.com
Motorola Solutions devices are professionally installed, the Radio Frequency Output Power will not exceed the
maximum allowable limit for the country of operation.
Antennas: Use only the supplied or an approved replacement antennas. Unauthorized antennas, modifications, or
attachments could cause damage and may violate regulations.
FCC Approval Statement
Federal Communications Commission
Office of Engineering and Technology
Laboratory Division
Interim Plans to Approve UNII Devices Operating in the 5470 - 5725 MHz Band with Radar Detection
and DFS Capabilities
The FCC, NTIA, FAA and industry are working to resolve interference to Terminal Doppler Weather Radar (TDWR)
systems used near airports that has occurred from some outdoor wireless systems operating in the 5470 MHz –
5725 MHz band. These wireless devices are subject to Section 15.407 of our rules and when operating as a
master device they are required to implement radar detection and DFS functions. We are continuing our work to
develop long-term equipment authorization test procedures that will ensure that the devices comply with our rules
that include protecting the TDWR operations. In the interim, the Commission will now allow certification of
wireless master devices with radar detection function and with DFS capability, if they meet the following
conditions:
1. Devices will not transmit on channels which overlap the 5600 – 5650 MHz band.1
2. Devices intended for outdoor use will be further restricted, as follows:
•
Devices must be professionally installed when operating in the 5470 – 5725 MHz band.2
•
Grantees must provide owners, operators and all such installers with specific instructions in their user’s
manual on requirements to avoid interference to TDWRs and information that meets the following
instructions:
• Any installation of either a master or a client device within 35 km of a TDWR location shall be separated
by at least 30 MHz (center-to-center) from the TDWR operating frequency 3, 4, and 5.
38
AP 7161 Access Point Installation Guide
1 The devices subject to the requirements in this KDB can select the initial channel for operation to avoid TDWRs
and apply the Uniform Channel Spreading requirements (see FCC 06-96 in ET Docket 03-122 released June 30,
2006) on the remaining available frequency band of operation. All the other test procedures including the test
radar patterns remain the same at the present time. A revision to the measurement procedure with modification
to the Uniform Channel Spreading requirement and other changes will be released in the future. The
Commission will also address the issue of any field upgrade option at that time.
2 The grantee must identify the specific expertise and the training required by the installers for installing these
types of devices.
3 In some instances it is possible that a device may be within 35 km of multiple TDWRs. In this case the device
must ensure that it avoids operation within 30 MHz for each of the TDWRs. This requirement applies even if the
master is outside the 35 km radius but communicates with outdoor clients which may be within the 35 km
radius of the TDWRs.
4 The requirement for ensuring 30 MHz frequency separation is based on the best information available to date. If
interference is not eliminated, a distance limitation based on line-of-sight from TDWR will need to be used. In
addition, devices with bandwidths greater than 20 MHz may require greater frequency separation.
• Procedures for the installers and the operators on how to register the devices in the industry-sponsored
database with the appropriate information regarding the location and operation of the device and installer
information is included.6
• Devices must meet all of the other requirements specified in Section 15.407, and it is prohibited to include
configuration controls (e.g. country code settings or other options to modify DFS functions) to change the
frequency of operations to any frequency other than those specified on the grant of certification for US
operation.7
• All applications for equipment authorization must clearly show compliance with all of the technical
requirements under worst case parameters, under user or operator control, based on frame rates, listen/talk
ratios and user data transfer conditions.
All the devices subject to the DFS requirements must be submitted to the Commission’s Laboratory Division for
pre-grant testing and equipment authorization.8 The applicant must ensure that all equipment authorization
applications subject to this interim procedure include appropriate attestations that the device has no option to
change the DFS parameters and that transmissions are disabled at least in the 5600 – 5650 MHz band. The
application must include the user’s manual with the appropriate installation and operations requirements for the
installers and operators.
We are continuing to evaluate additional measures that may need to be taken to further ensure against
interference caused by 5 GHz outdoor wireless systems located near airports. While manufacturers have an
obligation to ensure that their equipment complies with FCC rules, and must take steps to ensure their devices are
unlikely to cause harmful interference, Section 15.5 of the Commission’s rules also places an obligation on users
of devices to avoid causing interference and to correct any interference that may occur.
AP 7161 Access Point Installation Guide
39
We encourage the manufacturers to include information for the users, including the operators and installers, to
ensure that they understand that it is incumbent on them to cooperate with manufacturers to implement any
changes necessary to facilitate compliance.
5 Devices may be optionally designed not to transmit on channels which overlap 5570 – 5680 MHz instead of
requiring installers to perform site-by-site adjustments. In that case it is still required that the devices should be
installed professionally and the procedures for registering the device in the industry database should be included
in the Users Manual.
6 A voluntary WISPA sponsored database has been developed that allows operators and installers to register the
location information of the UNII devices operating outdoors in the 5470 – 5725 MHz band within 35 km of any
TDWR location (see http://www.spectrumbridge.com/udia/home.aspx). This database may be used by
government agencies in order to expedite resolution of any interference to TDWRs.
7 For example, device software must not have any country code options or software configuration settings which
allow an end user to modify the DFS operation or impact the performance of DFS. See KDB 594280.
8 The TCBs are not permitted to approve transmitters with radar detection capabilities. See KDB 628591.
9 The manufacturers may consider taking steps providing clear instructions to operators and installers of devices
as to the need to comply with rules for use of the band, guidance on registration of devices and any other
processes that are designed to avoid interference. They may use methods that include, but are not limited to,
instructions in manuals, notification on product web pages and service bulletins issued for products in the field.
TDWR Location Information
STATE CITY
LONGITUDE
LATITUDE
FREQUENCY
TERRAIN
ELEVATION
(MSL) [ft]
ANTENNA
HEIGHT
ABOVE
TERRAIN [ft]
GA
ATLANTA
W 084 15 44
N 33 38 48
5615 MHz
962
113
IL
MCCOOK
W 087 51 31
N 41 47 50
5615 MHz
646
97
IL
CRESTWOOD
W 087 43 47
N 41 39 05
645 MHz
663
113
IN
INDIANAPOLIS
W 086 26 08
N 39 38 14
5605 MHz
751
97
KS
WICHITA
W 097 26 48
N 37 30 26
5603 MHz
1270
80
KY
COVINGTON
W 084 34 48
N 38 53 53
5610 MHz
942
97
40
AP 7161 Access Point Installation Guide
STATE
CITY
LONGITUDE
LATITUDE
FREQUENCY
TERRAIN
ELEVATION
(MSL) [ft]
ANTENNA
HEIGHT
ABOVE
TERRAIN [ft]
KY
LOUISVILLE
W 085 36 38
N 38 02 45
5646 MHz
617
113
LA
NEW ORLEANS
W 090 24 11
N 30 01 18
5645 MHz
97
MA
BOSTON
W 070 56 01
N 42 09 30
5610 MHz
151
113
MD
BRANDYWINE
W 076 50 42
N 38 41 43
5635 MHz
233
113
MD
BENFIELD
W 076 37 48
N 39 05 23
5645 MHz
184
113
MD
CLINTON
W 076 57 43
N 38 45 32
5615 MHz
249
97
MI
DETROIT
W 083 30 54
N 42 06 40
5615 MHz
656
113
MN
MINNEAPOLIS
W 092 55 58
N 44 52 17
5610 MHz
1040
80
MO
KANSAS CITY
W 094 44 31
N 39 29 55
5605 MHz
1040
64
MO
SAINT LOUIS
W 090 29 21
N 38 48 20
5610 MHz
551
97
MS
DESOTO COUNTY
W 089 59 33
N 34 53 45
5610 MHz
371
113
NC
CHARLOTTE
W 080 53 06
N 35 20 14
5608 MHz
757
113
NC
RALEIGH
DURHAM
W 078 41 50
N 36 00 07
5647 MHz
400
113
NJ
WOODBRIDGE
W 074 16 13
N 40 35 37
5620 MHz
19
113
NJ
PENNSAUKEN
W 075 04 12
N 39 56 57
5610 MHz
39
113
NV
LAS VEGAS
W 115 00 26
N 36 08 37
5645 MHz
1995
64
NY
FLOYD BENNETT
FIELD
W 073 52 49
N 40 35 20
5647 MHz
97
OH
DAYTON
W 084 07 23
N 40 01 19
5640 MHz
922
97
OH
CLEVELAND
W 082 00 28
N 41 17 23
5645 MHz
817
113
OH
COLUMBUS
W 082 42 55
N 40 00 20
5605 MHz
1037
113
OK
AERO. CTR
TDWR #1
W 097 37 31
N 35 24 19
5610 MHz
1285
80
AP 7161 Access Point Installation Guide
41
STATE CITY
LONGITUDE
LATITUDE
FREQUENCY
TERRAIN
ELEVATION
(MSL) [ft]
ANTENNA
HEIGHT
ABOVE
TERRAIN [ft]
OK
AERO. CTR
TDWR #2
W 097 37 43
N 35 23 34
5620 MHz
1293
97
OK
TULSA
W 095 49 34
N 36 04 14
5605 MHz
712
113
OK
OKLAHOMA CITY
W 097 30 36
N 35 16 34
5603 MHz
1195
64
PA
HANOVER
W 080 29 10
N 40 30 05
5615 MHz
1266
113
PR
SAN JUAN
W 066 10 46
N 18 28 26
5610 MHz
59
113
TN
NASHVILLE
W 086 39 42
N 35 58 47
5605 MHz
722
97
TX
HOUSTON
INTERCONTL
W 095 34 01
N 30 03 54
5605 MHz
154
97
TX
PEARLAND
W 095 14 30
N 29 30 59
5645 MHz
36
80
TX
DALLAS LOVE
FIELD
W 096 58 06
N 32 55 33
5608 MHz
541
80
TX
LEWISDALE
DFW
W 096 55 05
N 33 03 53
5640 MHz
554
31
UT
SALT LAKE CITY
W 111 55 47
N 40 58 02
5610 MHz
4219
80
VA
LEESBURG
W 077 31 46
N 39 05 02
5605 MHz
361
113
WI
MILWAUKEE
W 088 02 47
N 42 49 10
5603 MHz
820
97113
Wireless Country Approvals
Regulatory markings are applied to the device signifying the radio(s) are approved for use in the following
countries: United States, Canada, Australia, and Europe.
Please refer to the Declaration of Conformity (DoC) for details of other country markings. This is available at:
http://www.motorola.com/doc.
Note 1: For 2.4 GHz Products: Europe includes, Austria, Belgium, Bulgaria, Czech Republic, Cyprus, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovak Republic, Slovenia, Spain, Sweden,
Switzerland and the United Kingdom.
Operation of the device without regulatory approval is illegal.
42
AP 7161 Access Point Installation Guide
Health and Safety Recommendations
The Federal Communications Commission (FCC) with its action in ET Docket 96-8 has adopted a safety standard
for human exposure to radio frequency (RF) electromagnetic energy emitted by FCC certified equipment. Motorola
Solutions products meet the uncontrolled environmental limits found in OET-65 and ANSI C95.1, 1991. Proper
operation of this radio according to the instructions found in this manual will result in user exposure that is
substantially below the FCC recommended limits.
Warnings for the Use of Wireless Devices
Please observe all warning notices with regard to the usage of wireless devices.
Potentially Hazardous Atmospheres
You are reminded of the need to observe restrictions on the use of radio devices in fuel depots, chemical plants
etc. and areas where the air contains chemicals or particles (such as grain, dust, or metal powders).
Safety in Hospitals
Wireless devices transmit radio frequency energy and may affect medical electrical equipment. When installed
adjacent to other equipment, it is advised to verify that the adjacent equipment is not adversely affected.
RF Exposure Guidelines
Safety Information
The device complies with internationally recognized standards covering human exposure to electromagnetic fields
from radio devices.
Reduce RF Exposure - Use Properly
Only operate the device in accordance with the instructions supplied.
Remote and Standalone Antenna Configurations
To comply with FCC RF exposure requirements, antennas that are mounted externally at remote locations or
operating near users at stand-alone desktop of similar configurations must operate with a minimum separation
distance of 28 cm from all persons.
Power Supply
Use only a power-over Ethernet 802.3at compliant solution. The required power rating is 25.5 Watts.
Wireless Devices - Countries
Country Selection
Select only the country in which you are using the device. Any other selection will make the operation of this
device illegal.
AP 7161 Access Point Installation Guide
43
Operation in the US
The available channels for 802.11 b/g operation in the US are Channels 1 to 11. The range of channels is limited
by firmware.
The FCC requires that the FCC ID label be placed on the outside of the device. If the device is placed in a
protective enclosure that requires tools to access, a permanent label with FCC ID must be placed on the exterior of
the protective enclosure
Radio Frequency Interference Requirements - FCC
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Radio Transmitters (Part 15)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Radio Frequency Interference Requirements - Canada
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Devices using the 5.470 – 5.725 GHz band shall not be capable of transmitting in the 5.60-5.65 GHz band in
Canada, make sure that Canada is the country selected during setup to ensure compliance.
Radio Transmitters
This device complies with RSS 210 of Industry & Science Canada. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference
received, including interference that may cause undesired operation.
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the
equivalent isotropically radiated power (EIRP) is not more than that permitted for successful communication.
44
AP 7161 Access Point Installation Guide
This device has been designed to operate with the antennas listed in this guide, and having a maximum gain of 8
dBi (2.4 GHz) and 10 dBi (5 GHz) for radios one and two. Antennas not included in this list, or having a gain greater
than 8 dBi (2.4 GHz) and 10 dBi (5 GHz) for radios one and two, are prohibited for use with this device. This device
has been designed to operate with the antennas listed in this guide, and having a maximum gain of 4.5 dBi (2.4
GHz) and 7.5 dBi (5 GHz) for radio three. Antennas not included in this list, or having a gain greater than 4.5 dBi
(2.4 GHz) and 7.5 dBi (5 GHz) for radio three, are strictly prohibited for use with this device. The required antenna
impedance is 50 ohms.
Label Marking: The Term "IC:" before the radio certification signifies that Industry Canada technical specifications
were met.
This device has been designed to operate with the antennas listed in the Enterprise Wireless LAN Antenna
Specification Guide. Refer to the guide at http://supportcentral.motorola.com.
CE Marking and European Economic Area (EEA)
The use of 2.4 GHz RLAN’s, for use through the EEA, have the following restrictions:
• Maximum radiated transmit power of 100 mW EIRP in the frequency range 2.400 -2.4835 GHz
• France outside usage, the equipment is restricted to 2.400-2.45 GHz frequency range.
• Italy requires a user license for outside usage
Statement of Compliance
Motorola Solutions hereby declares that this device is in compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC. A Declaration of Conformity may be obtained from
http://www.motorola.com/doc.
Other Countries
Australia
Use of 5 GHz RLAN’s in Australia is restricted in the following band: 5.50 – 5.65 GHz.
Brazil
Regulatory Declarations for AP 7161 - BRAZIL
Note: The certification mark applied to the AP 7161 is for Restrict Radiation Equipment. This equipment operates
on a secondary basis and does not have the right for protection against harmful interference from other users
including same equipment types. Also this equipment must not cause interference to systems operating on a
primary basis.
For more information consult the website www.anatel.gov.br
AP 7161 Access Point Installation Guide
45
Declarações Regulamentares para AP 7161 - Brasil
Nota: A marca de certificação se aplica ao Transceptor, modelo AP 7161. Este equipamento opera em caráter
secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo,
e não pode causar interferência a sistemas operando em caráter primário. Para maiores informações sobre
ANATEL consulte o site: www.anatel.gov.br
Chile
Este equipo cumple con la Resolución No 403 de 2008, de la Subsecretaria de telecomunicaciones, relativa a
radiaciones electromagnéticas.
This device complies with the Resolution Not 403 of 2008, of the Undersecretary of telecommunications, relating
to electromagnetic radiation.
Mexico
Restrict Frequency Range to: 2.450 – 2.4835 GHz.
Taiwan
NOTICE!
According to: Administrative Regulations on Low Power Radio Waves Radiated Devices
Article 12
Without permission granted by the DGT, any company, enterprise, or user is not allowed to change frequency,
enhance transmitting power or alter original characteristic as well as performance to a approved low power
radio-frequency devices.
Article 14
The low power radio-frequency devices shall not influence aircraft security and interfere with legal
communications; If found, the user shall cease operating immediately until no interference is achieved. The said
legal communications means radio communications are operated in compliance with the Telecommunications Act.
The low power radio-frequency devices must be susceptible with the interference from legal communications or
ISM radio wave radiated devices.
46
AP 7161 Access Point Installation Guide
Wireless device operates in the frequency band of 5.25-5.35 GHz, limited for indoor use only.
在 5.25-5.35 秭赫頻帶內操作之無線資訊傳輸設備,限於室內使用
AP 7161 Ace ess Point I nsta II ation Guide
1[
47
Waste Electrical and Electronic WEEE
English: For
EU Customers: All products at the end or their tile must be returned to Motorola
for recycling. For information on how to return product,please go to:
http://www.symbol.com/erwironmental_compliance.
Bulgallsh: 3a Kll"C>rrH OT EC: CnoA pa• Ha nonc3""" MM >K«OOT BCOIY K" npoAYKT" Tp•6ua
Aa ce BPbiJiaT Ha Motorola 3a pe[IHKilMpaHe. 3a l1Hr:j)OpMa[ll1OTHOCHO BPbiJiaHeTO Ha
npOAYKTI1, MOnSOT>1AeTe Ha aApec:http://www.symbot.com/weeetink.
tei1fna: Pro
zakazniky z EU:Vsechny produkty je nutne po skoncenf jejich zivotnosti vralit
spotecnosti Motorola k recyktaci. tnformace o zpusobu vraceni produktu najdete na
webove strance: http://www.symbot.com/cnvironmcntat_compitanco.
Danek: Tit kunder iEU: A tte produkter skat relurnereslit Motorolalit recirkutering, nar
de er
udtjent. L
Source Exif Data:
File Type : PDF
File Type Extension : pdf
MIME Type : application/pdf
PDF Version : 1.5
Linearized : No
Page Count : 52
Language : en-US
Tagged PDF : Yes
Title : AP 7161 Access Point Installation Guide
Author : rxb468
Creator : Microsoft® Word 2010
Create Date : 2012:11:19 10:23:58-05:00
Modify Date : 2012:11:19 10:23:58-05:00
Producer : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools