Zebra Technologies AP7532I Birch Internal (3x3 MIMO) User Manual AP 7532 Access Point Installation Guide
Zebra Technologies Corporation Birch Internal (3x3 MIMO) AP 7532 Access Point Installation Guide
Users Manual
MN000878A01B.fm Page 1 Thursday, July 10, 2014 11:18 AM AP-7532 Access Point INSTALLATION GUIDE MN000878A01B.fm Page 2 Thursday, July 10, 2014 11:18 AM AP-7532 Access Point MOTOROLA SOLUTIONS and the Stylized M Logo are registered in the US Patent & Trademark Office. © Motorola Solutions, Inc. 2014. All rights reserved. MN000878A01B.fm Page 3 Thursday, July 10, 2014 11:18 AM Installation Guide 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.1 Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.3 Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.4 AP-7532 Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.4.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.5 AP-7532 Antennas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.0 Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.1 Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.2 Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.3 Access Point Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.4 Power Injector System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.5 Wall Mount Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2.5.1 Wall Mount Procedure - New Installation . . . . . . . . . . . . . . . . . 12 2.5.2 Wall Mount Procedure - Existing Access Point Replacement . . 13 2.6 Suspended Ceiling T-Bar Mount Installation . . . . . . . . . . . . . . . . . . . 14 2.7 LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.0 Basic Access Point Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 4.0 AP-7532 Access Point Specifications . . . . . . . . . . . . . . . . . . . . . . . . 30 4.1 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 4.2 Physical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 4.3 Radio Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 5.0 Regulatory Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5.1 Regulatory Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5.2 Wireless Device Country Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5.2.1 Country Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.2.2 Frequency of Operation - FCC and IC . . . . . . . . . . . . . . . . . . . . . 33 5.3 Health and Safety Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . 34 5.3.1 Warnings for the use of Wireless Devices . . . . . . . . . . . . . . . . . 35 MN000878A01B.fm Page 4 Thursday, July 10, 2014 11:18 AM AP-7532 Access Point 5.3.2 Potentially Hazardous Atmospheres - Fixed Installations . . . . . . 35 5.3.3 Safety in Hospitals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 5.4 RF Exposure Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 5.4.1 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 5.4.2 International . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 5.4.3 EU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 5.4.4 US and Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 5.5 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 5.6 Radio Frequency Interference Requirements - FCC . . . . . . . . . . . . . . . 37 5.6.1 Radio Transmitters - Part 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 5.6.2 Radio Frequency Interference Requirements - Canada . . . . . . . . 37 5.7 CE Marking and European Economic Area (EEA) . . . . . . . . . . . . . . . . . 38 5.8 Statement of Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 5.9 Japan (VCCI) - Voluntary Control Council for Interference . . . . . . . . . 39 5.10 Korea Warning Statement for Class B ITE . . . . . . . . . . . . . . . . . . . . . 39 5.11 Other Countries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 5.12 Waste Electrical and Electronic Equipment (WEEE) . . . . . . . . . . . . . 41 5.13 Turkish WEEE Statement of Compliance . . . . . . . . . . . . . . . . . . . . . . 42 6.0 Motorola Solutions Support Center . . . . . . . . . . . . . . . . . . . . . . . . . . 43 7.0 AP-7532 Access Point China ROHS Compliance . . . . . . . . . . . . . . . 44 MN000878A01B.fm Page 5 Thursday, July 10, 2014 11:18 AM Installation Guide Introduction The AP-7532 external antenna and internal antenna Access Point’s are mid-tier Access Point’s with a relatively small footprint which supports functionality for dependable and efficient network performance.The AP-7532 is a 3x3:3 802.11ac Access Point utilizing one 2.4 GHz 802.11n radio and one 5 GHz 802.11ac radio. The Access Point housing is Plenum-rated (UL2043). The Access Point’s unique WiNG 5 software enables the Access Point to function as either a Standalone Access Point, an Adaptive Access Point, or a Virtual Controller. If new to Motorola Solutions Access Point technology, refer to the WiNG Access Point System Reference Guide to familiarize yourself with Access Point technology and the feature set supported by the WiNG operating system. The guide is available at https://portal.motorolasolutions.com/Support/US-EN/Wireless+Networks. This document is written for the qualified network device installer. 1.1 Document Conventions The following graphical alerts are used in this document to indicate notable situations: NOTE Tips, hints, or special requirements that you should take note of. CAUTION Care is required. Disregarding a caution can result in data loss or equipment malfunction. WARNING! Indicates a condition or procedure that could result in personal injury or equipment damage. MN000878A01B.fm Page 6 Thursday, July 10, 2014 11:18 AM AP-7532 Access Point 1.2 Warnings • • • • Read all installation instructions and site survey reports, and verify correct equipment installation before connecting the AP-7532 Access Point. Remove jewelry and watches before installing this equipment. Verify any device connected to this unit is properly wired and grounded. Verify there is adequate ventilation around the device, and that ambient temperatures meet equipment operation specifications. 1.3 Site Preparation • • • • • • Consult your site survey and network analysis reports to determine specific equipment placement, power drops, and so on. Assign installation responsibility to the appropriate personnel. Identify and document where all installed components are located. Ensure adequate, dust-free ventilation to all installed equipment. Identify and prepare Ethernet and console port connections. Verify cable lengths are within the maximum allowable distances for optimal signal transmission. 1.4 AP-7532 Package Contents An AP-7532 Access Point is available in both external antenna (AP-7532) and internal antenna (AP-7532I) configurations. An AP-7532 ships with the following: • • • AP-7532 Access Point AP-7532 Installation Guide (This Guide) Wall mount screws and mounting bracket 1.4.1 Features An AP-7532 Access Point supports the following feature set: • • • • Two RJ-45 connectors (GE1/POE and Console) Two LED indicators One 2.4 GHz 802.11n radio and one 5 GHz 802.11ac radio 3x3 MIMO, 3 spatial streams The GE1/POE accepts 802.3at or 802.3af compliant power from an external source. NOTE When operating in a Gigabit Ethernet environment, CAT-5e or CAT-6 cable is recommended for Gigabit operation. MN000878A01B.fm Page 7 Thursday, July 10, 2014 11:18 AM Installation Guide 1.5 AP-7532 Antennas An AP-7532 external antenna Access Point supports the following dual band antenna options: Part Number Antenna Type 2.4 GHZ Gain (dBi) 5 GHZ Gain (dBi) Impedance (Ohms) ML-2452-APA2-01 Dipole 3.17 4.6 50 ML-2452-HPA5-036 Dipole 50 ML-2452-APAG2A1-01 Dipole 2.7 1.7 50 ML-2452-PNA5-01R Panel 5.5 50 An AP-7532 internal antenna Access Point supports the following dual band antenna: Part Number BIRCH-INT-ANT Antenna Type Monopole 2.4 GHZ Gain (dBi) 4.13 5 GHZ Gain (dBi) Impedance (Ohms) 5.92 N/A MN000878A01B.fm Page 8 Thursday, July 10, 2014 11:18 AM AP-7532 Access Point Hardware Installation 2.1 Installation Instructions An AP-7532 Access Point mounts either on a wall (with M 3.5 x 0.6 x 23 MM pan head screws and mounting bracket- or equivalent) or on a suspended ceiling T-bar. To prepare for the installation: 1. Match the part number on the purchase order with the part numbers in the packing list and on the case of the Access Point. 2. Verify the contents of the box include the intended AP-7532 Access Point, and the included hardware matches the package contents (see AP-7532 Package Contents on page 6). Part Number Description AP-7532-67040-US AP-7532 dual radio 802.11ac 3x3:3 MIMO Access Point external antenna US version AP-7532-67040-WR AP-7532 dual radio 802.11ac 3x3:3 MIMO Access Point external antenna International version AP-7532-67040-EU AP-7532 dual radio 802.11ac 3x3:3 MIMO Access Point external antenna EU version AP-7532-67030-US AP-7532 dual radio 802.11ac 3x3:3 MIMO Access Point internal antenna US version AP-7532-67030-WR AP-7532 dual radio 802.11ac 3x3:3 MIMO Access Point internal antenna International version AP-7532-67030-EU AP-7532 dual radio 802.11ac 3x3:3 MIMO Access Point internal antenna EU version 3. Review site survey and network analysis reports to determine the location and mounting position for the AP-7532 Access Point. 4. Connect a CAT-5 or better Ethernet cable to a compatible 802.3at or 802.3af power source and run the cable to the installation site. Ensure there is sufficient slack on the cable to perform the installation steps. NOTE When operating in a Gigabit Ethernet environment, CAT-5e or CAT-6 cable is recommended for Gigabit operation. 2.2 Precautions Before installing an AP-7532 Access Point, verify the following: • Your are using the correctly rated power solution for the AP-7532 (either the AP-PSBIAS-2P3-ATR power injector or the PWRS-14000-54R external power supply) • Motorola Solutions recommends you do not to install the AP-7532 in wet or dusty areas. • Verify the environment has a continuous temperature range between -4° F to 104° F/-20° C to 40° C for external antenna Access Points and 32° F to 104° F/0° C to 40° C for internal antenna Access Points. MN000878A01B.fm Page 9 Thursday, July 10, 2014 11:18 AM Installation Guide 2.3 Access Point Placement For optimal performance, install the Access Point away from transformers, heavy-duty motors, fluorescent lights, microwave ovens, refrigerators and other industrial equipment. Signal loss can occur when metal, concrete, walls or floors block transmission. Install the Access Point in an open area or add Access Points as needed to improve coverage. Antenna coverage is analogous to lighting. Users might find an area lit from far away to be not bright enough. An area lit sharply might minimize coverage and create dark areas. Uniform antenna placement in an area (like even placement of a light bulb) provides even, efficient coverage. Install the Access Point at an ideal height of 10 feet from the ground. To maximize the Access Point’s radio coverage area, Motorola Solutions recommends conducting a site survey to define and document radio interference obstacles before installing the Access Point. 2.4 Power Injector System An AP-7532 Access Point can receive power via an Ethernet cable connected to the GE1/POE (LAN) port. When users purchase a WLAN solution, they often need to place Access Points in obscure locations. In the past, a dedicated power source was required for each Access Point in addition to the Ethernet infrastructure. This often required an electrical contractor to install power drops at each Access Point location. The Power Injector merges power and Ethernet into one cable, reducing the burden of installation and allowing optimal Access Point placement in respect to the intended coverage area. CAUTION Using a non-compliant injector, or an injector supporting legacy modes will not allow the AP-7532 to function at optimum performance levels. CAUTION Do not plug the AP-PSBIAS-2P3-ATR Power Injector into the Access Point’s Console port. Connecting the Power Injector into the console port can damage the port and void the AP-7532’s product warranty. The AP-7532’s supported Power Injector (Part No. AP-PSBIAS-2P3-ATR) is a high power POE Injector delivering up to 30 watts. The Access Point can only use a Power Injector when connecting the unit to the Access Point’s GE1/POE port. The Power Injector is separately ordered and not shipped with an existing AP SKU. MN000878A01B.fm Page 10 Thursday, July 10, 2014 11:18 AM 10 AP-7532 Access Point The Motorola Access Point Power Supply (Part No. PWRS-14000-54R) is not included with the Access Point and is orderable separately as an accessory. If the Access Point is provided both POE power and PWRS-14000-54R power concurrently, the Access Point will source power from the PWRS-14000-54R supply only. Disconnecting the AC power from the PWRS-14000-54R causes the Access Point to re-boot before sourcing power from the POE power injector. If the AP is operating using injector supplied power, the AP will not automatically reboot if an AC adapter is connected. The Access Point continues to operate with power supplied from the AC adapter without change to the Access Point operating configuration. If using AC adapter supplied power and a change to the AP’s operating configuration is warranted, the Access Point needs to be manually rebooted by the customer. CAUTION The Access Point supports any standards-based compliant power source (including non-Motorola Solutions power sources). However, using the wrong solution (including a POE system used on a legacy Motorola Solutions Access Point) could either limit functionality or severely damage the Access Point and void the product warranty. A separate Power Injector is required for each AP-7532 Access Point comprising the network. MN000878A01B.fm Page 11 Thursday, July 10, 2014 11:18 AM Installation Guide 11 The Power Injector can be installed free standing, on an even horizontal surface or wall mounted using the power injector’s wall mounting key holes. The following guidelines should be adhered to before cabling the Power Injector to an Ethernet source and an Access Point: • • • Do not block or cover airflow to the Power Injector. Keep the Power Injector away from excessive heat, humidity, vibration and dust. The Power Injector isn’t a repeater, and does not amplify the Ethernet signal. For optimal performance, ensure the Power Injector is placed as close as possible to the data port. CAUTION To avoid problematic performance and restarts, disable POE from a wired switch port connected to an Access Point if mid-span power sourcing equipment (PSE) is used between the two, regardless of the manufacturer of the switch. CAUTION Ensure AC power is supplied to the Power Injector using an AC cable with an appropriate ground connection approved for the country of operation. To install the Power Injector to an Ethernet data source and an Access Point: 1. Connect the Power Injector to an AC outlet (110VAC to 220VAC). 2. Connect an RJ-45 Ethernet cable between the Power Injector Data & Power Out connector and the Access Point’s GE1/POE port. 3. Connect an RJ-45 Ethernet cable between the network data supply (host) and the Power Injector Data In connector. Ensure the cable length from the Ethernet source (host) to the Power Injector and Access Point does not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The Injector receives power and is ready for device connection and operation as soon as AC power is applied. Refer to the Installation Guide shipped with the Power Injector for a description of the device’s LEDs. 2.5 Wall Mount Instructions A wall mount deployment requires hanging the AP-7532 Access Point with the provided mounting bracket and two screws. The AP-7532 can be mounted on to any plaster, wood or cement wall surface using the provided mounting bracket. The hardware required to install the AP-7532 on a wall consists of: • Two wide-shoulder Phillips pan head self-tapping screws (M3.5 x 0.6 x 23 mm) • Mounting bracket Optional customer provided installation tools include: • Phillips head screw driver, or drill and drill bit MN000878A01B.fm Page 12 Thursday, July 10, 2014 11:18 AM 12 AP-7532 Access Point 2.5.1 Wall Mount Procedure - New Installation This section describes a new AP-7532 installation with no previous Access Point existing on the intended wall surface. 1. Place the mounting bracket against the wall. 2. Mark the screw hole locations depending on the intended deployment orientation of the unit. NOTE When pre-drilling a hole the recommended hole size is 4mm (0.16in.). 3. At each point, drill a hole in the wall and attach the mounting bracket. 4. Place the Access Point on the mounting bracket. 5. Cable the Access Point using either the Power Injector solution (AP-PSBIAS-2P3-ATR) or the approved AP-7532 power supply (PWRS-14000-54R). MN000878A01B.fm Page 13 Thursday, July 10, 2014 11:18 AM Installation Guide 13 For Motorola Power Injector installations: a. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the Power Injector Data & Power Out connector and the Access Point’s GE1/POE port. b. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply (host) and the Power Injector Data In connector. c. Ensure the cable length from the Ethernet source (host) to the Power Injector and Access Point does not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The Power Injector receives power as soon as AC power is applied. For standard power adapter (non Power Injector) and line cord installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the Access Point’s GE1/POE port. b. Verify the power adapter is correctly rated according to the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable into the power connector on the Access Point. e. Attach the power supply line cord to a power supply. 6. Verify the Access Point is receiving power by observing the LEDs are lit or flashing. For more information on AP-7532 LED behavior, see LED Indicators on page 17. 7. The Access Point is ready to configure. CAUTION If not using an AP-PSBIAS-2P3-ATR power injector, ensure only the AP-7532’s designated power supply (PWRS-14000-54R) is used to supply power to the Access Point. Using an incorrectly rated power supply could damage the Access Point and void the product warranty. Do not actually connect to the power source until the cabling portion of the installation is complete. 2.5.2 Wall Mount Procedure - Existing Access Point Replacement An existing AP-7131 or AP-7131N Series Access Point installed on a wall can be replaced by an AP-7532. Simply remove the existing AP-7131 or AP-7131N and install the new provided mounting bracket for AP-7532 directly to the wall. The cabling procedure for such a replacement is as described in the previous section. MN000878A01B.fm Page 14 Thursday, July 10, 2014 11:18 AM 14 AP-7532 Access Point 2.6 Suspended Ceiling T-Bar Mount Instructions Ceiling mount requires holding the AP-7532 up against a T-bar of a suspended ceiling grid and twisting the unit on to the T-bar. If deploying the AP-7532 on a sculpted ceiling T-Bar, the Access Point mounting kit (Part No. KT-135628-01) can optionally be used as well. 1. First install the mounting bracket on the T-bar then attach the mounting bracket using the mounting slots on the Access Point. 2. Cable the Access Point using either the Power Injector solution (AP-PSBIAS-2P3-ATR) or the approved AP-7532 power supply (PWRS-14000-54R). MN000878A01B.fm Page 15 Thursday, July 10, 2014 11:18 AM Installation Guide 15 For Motorola Power Injector installations: a. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply (host) and the Power Injector Data In connector. b. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the Power Injector Data & Power Out connector and the Access Point’s GE1/POE port. c. Ensure the cable length from the Ethernet source (host) to the Power Injector and Access Point does not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The Power Injector receives power as soon as AC power is applied. For standard power adapter (non Power Injector) and line cord installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the Access Point’s GE1/POE port. b. Verify the power adapter is correctly rated according the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable into the power connector on the Access Point. e. Attach the power supply line cord to a power supply. CAUTION 3. If not using an AP-PSBIAS-2P3-ATR power injector, ensure only the AP-7532’s designated power supply (PWRS-14000-54R) is used to supply power to the Access Point. Using an incorrectly rated power supply could damage the Access Point and void the product warranty. Do not actually connect to the power source until the cabling portion of the installation is complete. Verify the unit has power by observing the LEDs. For more information on AP-7532 LED behavior, see LED Indicators on page 17. 4. 5. 6. 7. Align the bottom of the ceiling T-bar with the back of the Access Point. Orient the Access Point chassis by its length and the length of the ceiling T-bar. Rotate the Access Point chassis 45 degrees clockwise. Push the back of the Access Point chassis on to the bottom of the ceiling T-bar. MN000878A01B.fm Page 16 Thursday, July 10, 2014 11:18 AM 16 AP-7532 Access Point 8. Rotate the Access Point chassis 45 degrees counter-clockwise. The clips click as they fasten to the T-bar. 9. The Access Point is ready to configure. MN000878A01B.fm Page 17 Thursday, July 10, 2014 11:18 AM Installation Guide 17 2.7 LED Indicators The AP-7532 LED activity indicators are located on the front of the housing and are visible through the enclosure. MN000878A01B.fm Page 18 Thursday, July 10, 2014 11:18 AM 18 AP-7532 Access Point The LEDs provide a status display indicating error conditions, transmission, and network activity for the 5 GHz 802.11ac (amber) radio and the 2.4 GHz 802.11n (green) radio. Task 5 GHz Activity LED (Amber) 2.4 GHz Activity LED (Green) Unconfigured On Radio On Normal Operation • If this radio band is enabled: Blink at 5 second interval • If this radio band is disabled: Off • If there is activity on this band: Blink interval at 1 time per second • If this radio band is enabled: Blink at 5 second interval • If this radio band is disabled: Off • If there is activity on this band: Blink interval at 1 time per second Firmware Update On Off Locate AP Mode LEDs blink in an alternating green, red and amber pattern using an irregular blink rate. This LED state in no way resembles normal operating conditions. LEDs blink in an alternating green, red and amber pattern using an irregular blink rate. This LED state in no way resembles normal operating conditions MN000878A01B.fm Page 19 Thursday, July 10, 2014 11:18 AM Installation Guide 19 Basic Access Point Configuration Once the AP-7532 is installed and powered on, complete the following steps to get the Access Point up and running and access management functions: 1. The Access Point’s IP address is optimally provided using DHCP. A zero config IP address can also be derived if DHCP resources are unavailable. Using zero config, the last two octets in the IP address are the decimal equivalent of the last two bytes in the Access Point’s hardcoded MAC address. For example: MAC address - 00:C0:23:00:F0:0A Zero-config IP address - 169.254.240.10 To derive the Access Point’s IP address using its MAC address: a. Open the Windows calculator by selecting Start > All Programs > Accessories > Calculator. This menu path may vary slightly depending on your version of Windows. b. With the Calculator displayed, select View > Scientific. Select the Hex radio button. c. Enter a hex byte of the Access Point’s MAC address. For example, F0. d. Select the Dec radio button. The calculator converts F0 into 240. Repeat this process for the last Access Point MAC address octet. 2. Point the Web browser to the Access Point’s IP address. The following login screen displays: MN000878A01B.fm Page 20 Thursday, July 10, 2014 11:18 AM 20 AP-7532 Access Point 3. Enter the default username admin in the Username field. 4. Enter the default password motorola in the Password field. 5. Click the Login button to load the management interface. NOTE When logging in for the first time, you’re prompted to change the password to enhance device security in subsequent logins. NOTE If you get disconnected when running the wizard, you can connect again with the Access Point’s actual IP address (once obtained) and resume the wizard. 6. If this is the first time the management interface has been accessed, the Initial Setup Wizard automatically displays. MN000878A01B.fm Page 21 Thursday, July 10, 2014 11:18 AM Installation Guide NOTE 21 The Initial Setup Wizard displays the same pages and content for each Access Point type supported. The only difference being the number of radios configurable by Access Point type, as an AP7131 Access Point can support up to three radios, AP6522, AP6532, AP6562, AP8132 and AP7161 Access Points support two radios and AP6511 and AP6521 Access Points support a single radio. The Introduction screen displays the various actions that can be performed using the wizard under the Function Highlight field. Use the Choose One type to Setup the Access Point field options to select the type of wizard to run. The Typical Setup is the recommended wizard. This wizard uses the default parameters for most of the configuration parameters and sets up a working network with the least amount of manual configuration. The Advanced Setup wizard is for administrators who prefer more control over the different configuration parameters. A few more configuration screens are available for customization when the Advanced Setup wizard is used. The first page of the Initial Setup Wizard displays the Navigation Panel and Function Highlights for the configuration activities comprising the Access Point's initial setup. This page also displays options to select the typical or advanced mode for the wizard. The Navigation Panel for the Typical Setup Wizard displays the basic configuration options. A green checkmark to the left of an item in the Navigation Panel defines the task as having its minimum required configuration set correctly. A red X defines a task as still requiring at least one parameter be defined correctly. MN000878A01B.fm Page 22 Thursday, July 10, 2014 11:18 AM 22 AP-7532 Access Point 7. Select Save/Commit within each page to save the updates made to that page's configuration. Select Next to proceed to the next page listed in the Navigation Panel without saving your updates. NOTE While you can navigate to any page in the navigation panel, you cannot complete the Initial AP Setup Wizard until each task in the Navigation Panel has a green checkmark. For the purposes of this guide, use the Typical Setup (Recommended) option to simplify the process of getting the Access Point up and running quickly with a minimum number of changes to the Access Point’s default configuration. For information on using the Access Point’s Advanced Setup option, refer to the WiNG Access Point System Reference Guide to familiarize yourself with the feature set supported by the WiNG operating system. The guide is available at https://portal.motorolasolutions.com/Support/US-EN/Wireless+Networks. To configure the Access Point using the Typical Setup Wizard: 8. Select Typical Setup from the Choose One type to Setup the Access Point field on the Initial Setup Wizard. 9. The Typical Setup Wizard displays the Access Point Settings screen to define the Access Point's Standalone versus Virtual Controller AP functionality. This screen also enables selection of the country of operation for the Access Point. NOTE The professional installer should refer to the Motorola Solutions WiNG Access Point System Reference Guide available at https://portal.motorolasolutions.com/Support/US-EN/Wireless+Networks for detailed information on how to set the Access Point’s transmit power, antenna gain and channel in respect to the delployment country’s unique regulatory requirements. MN000878A01B.fm Page 23 Thursday, July 10, 2014 11:18 AM Installation Guide 23 10. Select an Access Point Type from the following options: • Virtual Controller AP - When more than one Access Point is deployed, a single Access Point can function as a Virtual Controller AP. Up to 24 Access Points can be connected to, and managed by, a single Virtual Controller AP of the same Access Point type. These connected Access Points must be the same type as the Virtual Controller AP. • Standalone AP - Select this option to deploy this Access Point as an autonomous fat Access Point. A Standalone AP isn't managed by a Virtual Controller AP, or adopted by a controller. NOTE If wanting to adopt the Access Point to a controller or service platform, use the controller or service platform’s resident UI to connect to the Access Point, provision its configuration and administrate the Access Point’s configuration. NOTE If designating the Access Point as a Standalone AP, Motorola Solutions recommends the Access Point’s UI be used exclusively to define its device configuration, and not the CLI. The CLI provides the ability to define more than one profile and the UI does not. Consequently, the two interfaces cannot be used collectively to manage profiles without an administrator encountering problems. 11. Select the Country Code of the country where the Access Point is deployed. Selecting a proper country is a critical task while configuring the Access Point, as it defines the correct channels of operation and ensures compliance to the regulations of the selected country. This field is only available for the Typical Setup Wizard. 12. Select Next to set the Access Point’s network mode. MN000878A01B.fm Page 24 Thursday, July 10, 2014 11:18 AM 24 AP-7532 Access Point 13. The Typical Setup Wizard displays the Network Topology screen to define how the Access Point handles network traffic. 14. Select an Access Point Mode from the available options. • Router Mode -In Router Mode, the Access Point routes traffic between the local network (LAN) and the Internet or external network (WAN). Router mode is recommended in a deployment supported by just a single Access Point. • Bridge Mode - In Bridge Mode, the Access Point depends on an external router for routing LAN and WAN traffic. Routing is generally used on one device, whereas bridging is typically used in a larger density network. Select Bridge Mode when deploying this Access Point with numerous peer Access Points supporting clients on both the 2.4GHz and 5GHz radio bands. NOTE When Bridge Mode is selected, WAN configuration cannot be performed and the Typical Setup Wizard does not display the WAN configuration screen. MN000878A01B.fm Page 25 Thursday, July 10, 2014 11:18 AM Installation Guide 25 15. Select Next. The Typical Setup Wizard displays the LAN Configuration screen to set the Access Point's LAN interface configuration. 16. Set the following DHCP and Static IP Address/Subnet information for the LAN interface: • Use DHCP - Select the checkbox to enable an automatic network address configuration using the Access Point’s DHCP server. • Static IP Address/Subnet - Enter an IP Address and a subnet for the Access Point's LAN interface. If Use DHCP is selected, this field is not available. When selecting this option, define the following DHCP Server and Domain Name Server (DNS) resources, as those fields will become enabled on the bottom portion of the screen. • Use on-board DHCP server to assign IP addresses to wireless clients - Select the checkbox to enable the Access Point’s DHCP server to provide IP and DNS information to clients on the LAN interface. • Range - Enter a starting and ending IP Address range for client assignments on the LAN interface. Avoid assigning IP addresses from x.x.x.1 - x.x.x.10 and x.x.x.255, as they are often reserved for standard network services. This is a required parameter. • Default Gateway - Define a default gateway address for use with the default gateway. This is a required parameter. MN000878A01B.fm Page 26 Thursday, July 10, 2014 11:18 AM 26 AP-7532 Access Point • DNS Forwarding - Select this option to allow a DNS server to translate domain names into IP addresses. If this option is not selected, a primary and secondary DNS resource must be specified. DNS forwarding is useful when a request for a domain name is made but the DNS server, responsible for converting the name into its corresponding IP address, cannot locate the matching IP address. • Primary DNS - Enter an IP Address for the main Domain Name Server providing DNS services for the Access Point's LAN interface. • Secondary DNS - Enter an IP Address for the backup Domain Name Server providing DNS services for the Access Point's LAN interface. 17. Select Next. The Typical Setup Wizard displays the Wireless LAN Setup screen to set the Access Point’s Wireless LAN interface configuration. 18. Set the following WLAN1 Configuration parameters: • SSID - Configure the SSID for the WLAN. • WLAN Type - Configure the encryption and authentication to use with this WLAN. • No Authentication and No Encryption - Configures a network without any authentication. This option also configures the network without encryption. This means that any data transmitted through the network is in plain text. Any device between end points can see the information transmitted. This is the least secure of all network configurations. • Captive Portal Authentication and No Encryption - Configures a network that uses a RADIUS server to authenticate users before allowing them on to the network. Once on the network, no encryption is used for the data being transmitted through the network. Select this option to use a Web page (either internally or externally hosted) to authenticate users before access is granted to the network. • PSK authentication, WPA2 encryption - Configures a network that uses PSK authentication and WPA2 encryption. Select this option to implement a pre-shared key that must be correctly shared between the Access Point and requesting clients using this WLAN. MN000878A01B.fm Page 27 Thursday, July 10, 2014 11:18 AM Installation Guide 27 19. Select Next. The Typical Setup Wizard displays the RADIUS Server Configuration screen if required. Otherwise, the Typical Setup Wizard displays the Summary and Commit screen. 20. Use the Radius Server Configuration screen to configure the users for the onboard RADIUS server. Use the screen to add, modify and remove RADIUS users. MN000878A01B.fm Page 28 Thursday, July 10, 2014 11:18 AM 28 AP-7532 Access Point 21. Select Add User to display the dialog to enter user information to add to the RADIUS server user database. 22. Enter the following user information: • Username - Provide a user name used to authenticate the user. • Password - Provide a password used to authenticate the user. • Confirm Password - Confirm the password by entering the same password as entered in the Password field. • Description - Provide a description to identify the user created in the RADIUS server database. 23. To create the entry in the RADIUS server database and add another user, select Create. To create the entry in the RADIUS server database and close the Add User dialog, select Create & Close. 24. Select Modify User on the RADIUS Server Configuration screen to modify information for an existing user from the RADIUS database. Highlight the user entry then select Modify User. NOTE The Username cannot be modified with this dialog. 25. Select Delete User on the RADIUS Server Configuration screen to remove information for an existing user from the RADIUS database. Highlight the user entry and select Delete User. 26. Select Confirm on the dialog displayed. The entry for the user is removed from the RADIUS database. 27. To dismiss the dialog without adding, modifying or removing entries in the RADIUS server database, select Cancel. MN000878A01B.fm Page 29 Thursday, July 10, 2014 11:18 AM Installation Guide 29 28. Select Next. The Typical Setup Wizard displays the Summary and Commit screen to summarize the screens (pages) and settings updated using the Typical Setup Wizard. No user intervention or additional settings are required. Its an additional means of validating the Access Point’s updated configuration before it’s deployed. However, if a screen displays settings not intended as part of the initial configuration, then any screen can be selected again from within the Navigation Panel and its settings modified accordingly. If the configuration displays as intended, select Save/Commit to implement these settings to the Access Point’s configuration. If additional changes are warranted based on the summary, either select the target page from the Navigational Panel, or use the Back and Next buttons to scroll to the target screen. MN000878A01B.fm Page 30 Thursday, July 10, 2014 11:18 AM 30 AP-7532 Access Point AP-7532 Access Point Specifications 4.1 Electrical Characteristics An AP-7532 Access Point has the following electrical characteristics: Operating Current & Voltage 12VDC, 1.25A (AUX input voltage) 12VDC PWRS-14000-54R power supply 48VDC, 0.375A (POE) 802.3at AP-PSBIAS-2P3-ATR Power Injector 4.2 Physical Characteristics An AP-7532 Access Point has the following physical characteristics: Dimensions 7.1 in. L x 6.5 in. W x 1.6 in. H 180 mm L x 165 mm W x 41 mm H Housing Plenum-rated housing (UL2043) Weight 1.8 lbs/0.82 kg Operating Temperature External antennas: -4° F to 104° F/-20° C to 40° C Internal antennas: 32° F to 104° F/0° C to 40° C Storage Temperature -40° F to 158° F/-40° C to 70° C Operating Humidity 85% RH non-condensing Operating Altitude (maximum) 8,000 ft @ 28C Storage Altitude (maximum) 30,000 ft @ 12C Electrostatic Discharge External antennas: 12KV air, 6 KV contact Internal antenna: 15KV air, 8KV contact MN000878A01B.fm Page 31 Thursday, July 10, 2014 11:18 AM Installation Guide 31 4.3 Radio Characteristics The AP-7532 Access Point has the following radio characteristics: Data Rates Supported 802.11b/g: 1,2,5.5,11,6,9,12,18,24,36,48 and 54 Mbps 802.11a: 6,9,12,18,24,36,48, and 54 Mbps 802.11n: MCS 0-23 up to 450 Mbps 802.11ac: MCS 0-9 up to 1.3 Gbps Wireless Medium Direct Sequence Spread Spectrum (DSSS) Orthogonal Frequency Division Multiplexing (OFDM) Spatial multiplexing (MIMO) Network Standards IEEE 802.11a/b/g/n/ac 802.11d and 802.11i WPA2 WMM and WMM-UAPSD Transmit Power Adjustment 1dB increments MN000878A01B.fm Page 32 Thursday, July 10, 2014 11:18 AM 32 AP-7532 Access Point Regulatory Information 5.1 Regulatory Information This device is approved under Motorola Solutions, Inc. This guide applies to the following Model Numbers: AP-7532, AP-7532I. All Motorola Solutions devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Local language translations are available at the following website: https://portal.motorolasolutions.com/Support/US-EN/Wireless+Networks Any changes or modifications to Motorola Solutions equipment, not expressly approved by Motorola Solutions, could void the user's authority to operate the equipment. Motorola Solutions devices are professionally installed, the Radio Frequency Output Power will not exceed the maximum allowable limit for the country of operation. Antennas: Use only the supplied or an approved replacement antenna. Unauthorized antennas, modifications, or attachments could cause damage and may violate regulations. This device is only to be used with a Motorola Solutions Wireless Switch. Declared maximum operating temperature: 40°C. 5.2 Wireless Device Country Approvals Regulatory markings, subject to certification, are applied to the device signifying the radio(s) is/are approved for use in the following countries: United States, Canada, Japan, China, S. Korea, Australia, and Europe 1 Please refer to the Declaration of Conformity (DoC) for details of other country markings. This is available at: http://www.motorolasolutions.com/doc Note: For 2.4GHz or 5GHz Products: Europe includes, Austria, Belgium, Bulgaria, Czech Republic, Cyprus, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovak Republic, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Operation of the device without regulatory approval is illegal. MN000878A01B.fm Page 33 Thursday, July 10, 2014 11:18 AM Installation Guide 33 5.2.1 Country Selection Select only the country in which you are using the device. Any other selection will make the operation of this device illegal. Some Access Points are specifically designed to operate in certain countries (Example; -US for the United States, -EU for the European Union). Country Roaming This device incorporates the International Roaming feature (IEEE802.11d) which will ensure the product operates on the correct channels for the particular country of use. 5.2.2 Frequency of Operation – FCC and IC 5 GHz Only Industry Canada Statement: Caution: The device for the band 5150-5250 MHz is only for indoor usage to reduce potential for harmful interference to co-Channel mobile satellite systems. High power radars are allocated as primary users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars could cause interference and/or damage to LE-LAN devices. Avertissement: Le dispositif fonctionnant dans la bande 5150-5250 MHz est réservé uniquement pour une utilisation à l'intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux. Les utilisateurs de radars de haute puissance sont désignés utilisateurs principaux (c.-à-d., qu'ils ont la priorité) pour les bands 5250-5350 MHz et 5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL. 2.4 GHz Only The available channels for 802.11bg operation in the US are Channels 1 to 11. The range of channels is limited by firmware. Indoor Use This device was designed for Indoor use. MN000878A01B.fm Page 34 Thursday, July 10, 2014 11:18 AM 34 AP-7532 Access Point 5.3 Health and Safety Recommendations Ergonomic Recommendations Caution: In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below. Consult with your local Health & Safety Manager to ensure that you are adhering to your company's safety programs to prevent employee injury. • • • • • • • • • • • Reduce or eliminate repetitive motion Maintain a natural position Reduce or eliminate excessive force Keep objects that are used frequently within easy reach Perform tasks at correct heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedures Vehicle Installation RF signals may affect improperly installed or inadequately shielded electronic systems in motor vehicles (including safety systems). Check with the manufacturer or its representative regarding your vehicle. You should also consult the manufacturer of any equipment that has been added to your vehicle. An air bag inflates with great force. DO NOT place objects, including either installed or portable wireless equipment, in the area over the air bag or in the air bag deployment area. If in-vehicle wireless equipment is improperly installed and the air bag inflates, serious injury could result. Position your device within easy reach. Be able to access your device without removing your eyes from the road. Note: Connection to an alert device that will cause a vehicle horn to sound or lights to flash, on receipt of a call on public roads, is not permitted. IMPORTANT Before installing or using, check state and local laws regarding windshield mounting and use of equipment. For Safe installation • Do not put your phone in a location that obstructs the drivers vision or interferes with the operation of the Vehicle. • Do not cover an airbag. MN000878A01B.fm Page 35 Thursday, July 10, 2014 11:18 AM Installation Guide 35 Safety on the Road Do not take notes or use the device while driving. Jotting down a "to do" list or flipping through your address book takes attention away from your primary responsibility, driving safely. When driving a car, driving is your first responsibility - Give full attention to driving. Check the laws and regulations on the use of wireless devices in the areas where you drive. Always obey them. 5.3.1 Warnings for the use of Wireless Devices Please observe all warning notices with regard to the usage of wireless devices. 5.3.2 Potentially Hazardous Atmospheres – Fixed Installations You are reminded of the need to observe restrictions on the use of radio devices in fuel depots, chemical plants etc. and areas where the air contains chemicals or particles (such as grain, dust, or metal powders). 5.3.3 Safety in Hospitals Wireless devices transmit radio frequency energy and may affect medical electrical equipment. When installed adjacent to other equipment, it is advised to verify that the adjacent equipment is not adversely affected. Pacemakers Pacemaker manufacturers recommended that a minimum of 15cm (6 inches) be maintained between a handheld wireless device and a pacemaker to avoid potential interference with the pacemaker. These recommendations are consistent with independent research and recommendations by Wireless Technology Research. Persons with Pacemakers: • Should ALWAYS keep the device more than 15cm (6 inches) from their pacemaker when turned ON. • Should not carry the device in a breast pocket. • Should use the ear furthest from the pacemaker to minimize the potential for interference. • If you have any reason to suspect that interference is taking place, turn OFF your device. Other Medical Devices Please consult your physician or the manufacturer of the medical device, to determine if the operation of your wireless product may interfere with the medical device. MN000878A01B.fm Page 36 Thursday, July 10, 2014 11:18 AM 36 AP-7532 Access Point 5.4 RF Exposure Guidelines 5.4.1 Safety Information Reducing RF Exposure - Use Properly Only operate the device in accordance with the instructions supplied. 5.4.2 International The device complies with internationally recognized standards covering human exposure to electromagnetic fields from radio devices. For information on “International” human exposure to electromagnetic fields refer to the Motorola Solutions Declaration of Conformity (DoC) at: http://www.motorolasolutions.com/doc For further information on the safety of RF energy from wireless devices - see http://responsibility.motorolasolutions.com/index.php/downloads/ located under Wireless Communications and Health 5.4.3 EU Remote and Standalone Antenna Configurations To comply with EU RF exposure requirements, antennas that are mounted externally at remote locations or operating near users at stand-alone desktop of similar configurations must operate with a minimum separation distance of 25cm from all persons. 5.4.4 US and Canada Co-located statement To comply with FCC RF exposure compliance requirements, the antenna used for this transmitter must not be co-located or operating in conjunction with any other transmitter/antenna except those already approved in this filling. To satisfy US and Canadian RF exposure requirements, a transmitting device must operate with a minimum separation distance of 25cm or more from a person's body. Pour satisfaire aux exigences Américaines et Canadiennes d'exposition aux radiofréquences, un dispositif de transmission doit fonctionner avec une distance de séparation minimale de 25cm ou plus de corps d'une personne. Radiation Exposure Statement This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 25cm between the radiator and your body. NOTE IMPORTANTE: (Pour l'utilisation de dispositifs mobiles) Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 25cm de distance entre la source de rayonnement et votre corps. MN000878A01B.fm Page 37 Thursday, July 10, 2014 11:18 AM Installation Guide 37 Remote and Standalone Antenna Configurations To comply with FCC RF exposure requirements, Antennas that are mounted externally must be professionally installed at a fixed location and operate with a minimum distance of 25cm from all persons. To comply with FCC Antenna requirements, the Antenna must be adjusted such that the RF emission lobes are below 30 degrees elevation. 5.5 Power Supply This device must be powered from a 802.3af or 802.3at compliant power source which has been certified by the appropriate agencies, or by a Motorola approved UL LISTED ITE (IEC/EN 60950-1, LPS/SELV) power supply with electrical ratings: Output 12 Vdc, min 1.25 A or 48 Vdc min 0.375 A (POE), with a recommended ambient temperature greater than 40 degrees C. Use of alternative power supply will invalidate any approvals given to this unit and may be dangerous. 5.6 Radio Frequency Interference Requirements—FCC This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • • • • Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/TV technician for help. 5.6.1 Radio Transmitters (Part 15) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 5.6.2 Radio Frequency Interference Requirements - Canada CAN ICES-3 (B)/NMB-3(B) Radio Transmitters For RLAN Devices: The use of 5 GHz RLAN’s, for use in Canada, have the following restrictions: • Restricted Band 5.60 – 5.65 GHz MN000878A01B.fm Page 38 Thursday, July 10, 2014 11:18 AM 38 AP-7532 Access Point This device complies with RSS 210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Label Marking: The Term "IC:" before the radio certification only signifies that Industry Canada technical specifications were met In accordance with the regulations of Industry Canada, this radio transmitter can operate with an antenna of a type and a maximum gain (or lower) approved for the transmitter by Industry Canada. With the aim of reducing the risk of radio interference to other users, the chosen antenna type and its gain should be selected so that the equivalent isotropically radiated power (e.i.r.p.) does not exceed the intensity necessary for the establishment of a satisfactory connection. Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectriqueà l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire àl'établissement d'une communication satisfaisante. In compliance with respective local regulatory law, Motorola Solutions AP software provides professional installers the option to configure the antenna type and antenna gain for approved antennas. This radio transmitter (AP-7532, AP-7532I) has been approved by Industry Canada to operate with the antenna types listed below and having a maximum gain allowable and the impedance required for each type of antenna. The antenna types not included in this list, or whose gain is higher than the maximum gain indicates, are strictly prohibited for the operation of the transmitter. Refer to AP-7532 Antennas on page 7 for a listing of the 2.4 GHz and 5 GHz antennas initially approved for use with AP-7532 and AP7532I Access Points. Le présent émetteur radio (AP-7532, AP-7532I) a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur. 5.7 CE Marking and European Economic Area (EEA) WARNING: This is a Class B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. The use of 2.4GHz RLAN’s, for use through the EEA, have the following restrictions: • Maximum radiated transmit power of 100 mW EIRP in the frequency range 2.400 -2.4835 GHz. MN000878A01B.fm Page 39 Thursday, July 10, 2014 11:18 AM Installation Guide 39 5.8 Statement of Compliance Motorola hereby, declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A Declaration of Conformity may be obtained from http://www.motorolasolutions.com/doc. 5.9 Japan (VCCI) - Voluntary Control Council for Interference Class B ITE 5.10 Korea Warning Statement for Class B ITE 5.11 Other Countries Australia Use of 5GHz RLAN’s in Australia is restricted in the following band 5.50 – 5.65GHz. Brazil Declarações Regulamentares para AP-7532 - Brasil Nota: A marca de certificação se aplica ao Transceptor, modelo AP-7532. Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário. Para maiores informações sobre ANATEL consulte o site: www.anatel.gov.br Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário. Este produto está homologado pela Anatel, de acordo com os procedimentos regulamentados pela Resolução n°242/2000 e atende aos requisitos técnicos aplicados, incluindo os limites de exposição da Taxa de Absorção Específica referente a campos elétricos, magnéticos e eletromagnéticos de radiofrequência, de acordo com as Resoluções n° 303/2002 e 533/2009. Este dispositivo está em conformidade com as diretrizes de exposição à radiofrequência quando posicionado pelo menos 25 centímetros de distância do corpo. Para maiores informações, consulte o site da Anatel MN000878A01B.fm Page 40 Thursday, July 10, 2014 11:18 AM 40 AP-7532 Access Point Chile Este equipo cumple con la Resolución No 403 de 2008, de la Subsecretaria de telecomunicaciones, relativa a radiaciones electromagnéticas. China Mexico Restrict Frequency Range to: 2.450 – 2.4835 GHz. S. Korea Taiwan 在 5.25-5.35 秭赫頻帶內操作之無線資訊傳輸設備,限於室內使用 Thailand MN000878A01B.fm Page 41 Thursday, July 10, 2014 11:18 AM Installation Guide 41 5.12 Waste Electrical and Electronic Equipment (WEEE) English: For EU Customers: All products at the end of their life must be returned to Motorola Solutions for recycling. For information on how to return product, please go to: http://www.motorolasolutions.com/recycling/weee. Français: Clients de l'Union Européenne: Tous les produits en fin de cycle de vie doivent être retournés à Motorola Solutions pour recyclage. Pour de plus amples informations sur le retour de produits, consultez : http://www.motorolasolutions.com/recycling/weee. Español: Para clientes en la Unión Europea: todos los productos deberán entregarse a Motorola Solutions al final de su ciclo de vida para que sean reciclados. Si desea más información sobre cómo devolver un producto, visite: http://www.motorolasolutions.com/recycling/weee. Б :З ЕС: С я я я Mлрлолиa Sлисрелкп .З я я : дррм://ууу.mлрлолиaплисрелкп.cлm/обcycиекг/уббб. Deutsch: Für Kunden innerhalb der EU: Alle Produkte müssen am Ende ihrer Lebensdauer zum Recycling an Motorola Solutions zurückgesandt werden. Informationen zur Rücksendung von Produkten finden Sie unter http://www.motorolasolutions.com/recycling/weee. Italiano: per i clienti dell'UE: tutti i prodotti che sono giunti al termine del rispettivo ciclo di vita devono essere restituiti a Motorola Solutions al fine di consentirne il riciclaggio. Per informazioni sulle modalità di restituzione, visitare il seguente sito Web: http://www.motorolasolutions.com/recycling/weee. Português: Para clientes da UE: todos os produtos no fim de vida devem ser devolvidos à Motorola Solutions para reciclagem. Para obter informações sobre como devolver o produto, visite: http://www.motorolasolutions.com/recycling/weee. Nederlands: Voor klanten in de EU: alle producten dienen aan het einde van hun levensduur naar Motorola Solutions te worden teruggezonden voor recycling. Raadpleeg http://www.motorolasolutions.com/recycling/weee voor meer informatie over het terugzenden van producten. Polski: Klienci z obszaru Unii Europejskiej: Produkty wycofane z eksploatacji nale¿y zwróciæ do firmy Motorola Solutions w celu ich utylizacji. Informacje na temat zwrotu produktów znajduj¹ siê na stronie internetowej http://www.motorolasolutions.com/recycling/weee. Čeština: Pro zákazníky z EU: Všechny produkty je nutné po skonèení jejich životnosti vrátit spoleènosti Motorola Solutions k recyklaci. Informace o zpùsobu vrácení produktu najdete na webové stránce: http://www.motorolasolutions.com/recycling/weee. Eesti: EL klientidele: kõik tooted tuleb nende eluea lõppedes tagastada taaskasutamise eesmärgil Motorola Solutions'ile. Lisainformatsiooni saamiseks toote tagastamise kohta külastage palun aadressi: http://www.motorolasolutions.com/recycling/weee. Magyar: Az EU-ban vásárlóknak: Minden tönkrement terméket a Motorola Solutions vállalathoz kell eljuttatni újrahasznosítás céljából. A termék visszajuttatásának módjával kapcsolatos tudnivalókért látogasson el a http://www.motorolasolutions.com/recycling/weee weboldalra. Svenska: För kunder inom EU: Alla produkter som uppnått sin livslängd måste returneras till Motorola Solutions för återvinning. Information om hur du returnerar produkten finns på http://www.motorolasolutions.com/recycling/weee. Suomi: Asiakkaat Euroopan unionin alueella: Kaikki tuotteet on palautettava kierrätettäväksi Motorola Solutions-yhtiöön, kun tuotetta ei enää käytetä. Lisätietoja tuotteen palauttamisesta on osoitteessa http://www.motorolasolutions.com/recycling/weee. MN000878A01B.fm Page 42 Thursday, July 10, 2014 11:18 AM 42 AP-7532 Access Point Dansk: Til kunder i EU: Alle produkter skal returneres til Motorola Solutions til recirkulering, når de er udtjent. Læs oplysningerne om returnering af produkter på: http://www.motorolasolutions.com/recycling/weee. Ε ην ά: Γ α π Ε.Ε.: Ό α α π ο α, ο ο α ου , π π α π φο α Motorola Solutions γ α α α . Γα π π οφο χ π οφ π ο ο , π φ υ http://www.motorolasolutions.com/recycling/weee ο ∆ α υο. Malti: Għal klijenti fl-UE: il-prodotti kollha li jkunu waslu fl-aħħar tal-ħajja ta' l-użu tagħhom, iridu jiġu rritornati għand Motorola Solutions għar-riċiklaġġ. Għal aktar tagħrif dwar kif għandek tirritorna l-prodott, jekk jogħġbok żur: http://www.motorolasolutions.com/recycling/weee. Românesc: Pentru clienţii din UE: Toate produsele, la sfârşitul duratei lor de funcţionare, trebuie returnate la Motorola Solutions pentru reciclare. Pentru informaţii despre returnarea produsului, accesaţi: http://www.motorolasolutions.com/recycling/weee. Slovenski: Za kupce v EU: vsi izdelki se morajo po poteku življenjske dobe vrniti podjetju Motorola Solutions za reciklažo. Za informacije o vračilu izdelka obiščite: http://www.motorolasolutions.com/recycling/weee. Slovenčina: Pre zákazníkov z krajín EU: Všetky výrobky musia byť po uplynutí doby ich životnosti vrátené spoločnosti Motorola Solutions na recykláciu. Bližšie informácie o vrátení výrobkov nájdete na: http://www.motorolasolutions.com/recycling/weee. Lietuvių: ES vartotojams: visi gaminiai, pasibaigus jų eksploatacijos laikui, turi būti grąžinti utilizuoti į kompaniją „Motorola Solutions“. Daugiau informacijos, kaip grąžinti gaminį, rasite: http://www.motorolasolutions.com/recycling/weee. Latviešu: ES klientiem: visi produkti pēc to kalpošanas mūža beigām ir jānogādā atpakaļ Motorola Solutions otrreizējai pārstrādei. Lai iegūtu informāciju par produktu nogādāšanu Motorola, lūdzu, skatiet: http://www.motorolasolutions.com/recycling/weee. Türkçe: AB Müşterileri için: Kullanım süresi dolan tüm ürünler geri dönüştürme için Motorola Solutions'ya iade edilmelidir. Ürünlerin nasıl iade edileceği hakkında bilgi için lütfen şu adresi ziyaret edin: http://www.motorolasolutions.com/recycling/weee. 5.13 TURKISH WEEE Statement of Compliance EEE Yönetmeliğine Uygundur MN000878A01B.fm Page 43 Thursday, July 10, 2014 11:18 AM Installation Guide 43 Motorola Solutions Support Center If you have a problem with your equipment, contact support for your region. Contact information is available at: https://portal.motorolasolutions.com/Support/US-EN When contacting Motorola Solutions support, please provide the following information: • Serial number of the unit • Model number or product name • Software type and version number Motorola Solutions responds to calls by e-mail, telephone, or fax within the time limits set forth in support agreements. If you purchased your product from a Motorola Solutions business partner, contact that business partner for support. Customer Support Web Sites The Motorola Solutions Support Central Web site, located at https://portal.motorolasolutions.com/Support/US-EN. provides information and online assistance including developer tools, software downloads, product manuals and online repair requests. Manuals https://portal.motorolasolutions.com/Support/US-EN/Wireless+Networks. General Information Obtain additional information by contacting Motorola Solutions at: Telephone (North America): 1-800-722-6234 Telephone (International): +1-631-738-5200 Website: http://www.motorolasolutions.com MN000878A01B.fm Page 44 Thursday, July 10, 2014 11:18 AM 44 AP-7532 Access Point AP-7532 Access Point China ROHS Compliance 有毒有害物质或元素 部件名称 (Parts) 金属部件 (Metal Parts) 电路模块 (Circuit Modules) 电缆及电缆组件 (Cables and Cable Assemblies) 塑料和聚合物部件 (Plastic and Polymeric Parts) 光学和光学组件 (Optics and Optical Components) 电池 (Batteries) 15 多溴二苯 醚 (PBDE) 铅 (Pb) 汞 (Hg) 镉 (Cd) 多溴联 苯 (PBB) 六价铬 (Cr6+) O:表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ/T11363-2006 标准规定的限量要求以 下。 X:表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ/T11363-2006 标准规定的限量 要求。 对销售之日的所售产品,本表表示,公司供应链的电子信息产品可能包含这些物质。注意:在所售产品 中可能会也可能不会含有所有所列的部件。 This table was created to comply with China RoHS requirements for Motorola Solutions‘ AP-7532 and AP-7532I Access Points. MN000878A01B.fm Page 45 Thursday, July 10, 2014 11:18 AM Installation Guide 45 MN000878A01B.fm Page 46 Thursday, July 10, 2014 11:18 AM 46 AP-7532 Access Point MN000878A01B.fm Page 47 Thursday, July 10, 2014 11:18 AM Installation Guide 47 MN000878A01B.fm Page 48 Thursday, July 10, 2014 11:18 AM Motorola Solutions, Inc. 1301 E. Algonquin Rd. Schaumburg, IL 60196-1078, U.S.A. http://www.motorolasolutions.com MOTOROLA, MOTO, MOTOROLA SOLUTIONS and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings, LLC and are used under license. All other trademarks are the property of their respective owners. © 2014 Motorola Solutions, Inc. All Rights Reserved. MN000878A01 Revision B July 2014
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Author : Motorola Solutions, Inc. Create Date : 2014:07:10 11:18:55-04:00 Modify Date : 2014:07:11 19:02:46+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2014:07:11 19:02:46+08:00 Format : application/pdf Title : AP-7532 Access Point Installation Guide Creator : Motorola Solutions, Inc. Producer : Acrobat Distiller 11.0 (Windows) Document ID : uuid:5727c9b9-d6a3-43ee-8363-f8f52073d78a Instance ID : uuid:ef036779-e9f1-42cf-aeae-e6e408c9ed30 Page Count : 48EXIF Metadata provided by EXIF.tools