Zebra Technologies DS6878 Barcode scanner with integrated Bluetooth User Manual Symbol DS6878 Product Reference Guide
Zebra Technologies Corporation Barcode scanner with integrated Bluetooth Symbol DS6878 Product Reference Guide
Contents
- 1. User Manual II
- 2. User Manual III
- 3. User Manual I
User Manual II
Chapter 9 IBM Interface Introduction This chapter provides instructions for programming the cradle to interface with an IBM 468X/469X host computer. Throughout the programming bar code menus, default values are indicated with asterisks (*). * Indicates Default *Disable Convert to Code 39 Feature/Option 9-2 Symbol DS6878 Product Reference Guide Connecting to an IBM 468X/469X Host NOTE See Chapter 4, Radio Communications for information about digital scanner/cradle pairing and wireless communication The digital scanner must be connected to the cradle for the host parameter setting to take effect. When the digital scanner is not connected to a cradle, and a host parameter bar code is scanned, a long low/long high beep sequence sounds. This connection is made directly from the cradle to the host interface. Interface Cable Host Port Connector Figure 9-1 IBM Direct Connection To connect the IBM 46XX interface: 1. Attach the modular connector of the IBM 46XX interface cable to the host port on the bottom of the digital scanner cradle (see Connecting the Cables to the Cradle on page 1-6). 2. Connect the other end of the IBM 46XX interface cable to the appropriate port on the host (typically Port 9). 3. Select the port address by scanning the appropriate bar code from Port Address on page 9-4. 4. To modify any other parameter options, scan the appropriate bar codes in this chapter. NOTE Interface cables vary depending on configuration. The connectors illustrated in Figure 9-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the cradle remain the same. If a power supply is used, disconnect the power supply before changing host cables or the cradle may not recognize the new host. The only required configuration is the port number. Other digital scanner parameters are typically controlled by the IBM system. IBM Interface IBM Parameter Defaults Table 9-1 lists the defaults for IBM host parameters. To change any option, scan the appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 9-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters. Table 9-1 IBM Host Default Table Parameter Default Page Number IBM 468X/469X Host Parameters Port Address None Selected 9-4 Convert Unknown to Code 39 Disable 9-5 Ignore Beep Disable 9-5 Ignore Bar Code Configuration Disable 9-6 9-3 9-4 Symbol DS6878 Product Reference Guide IBM 468X/469X Host Parameters Port Address This parameter sets the IBM 468X/469X port used. NOTE Scanning one of these bar codes enables the RS-485 interface on the digital scanner. * None Selected Hand-held Scanner Emulation (Port 9B)1 Non-IBM Scanner Emulation (Port 5B) Table-top Scanner Emulation (Port 17) NOTE User selection is required to configure this interface and this is the most common selection. IBM Interface 9-5 Convert Unknown to Code 39 Scan a bar code below to enable or disable the conversion of unknown bar code type data to Code 39. Enable Convert Unknown to Code 39 *Disable Convert Unknown to Code 39 Optional IBM Parameters If you configure the digital scanner and find the settings were not saved, or changed, when the system is restarted scan the bar codes that follow to override IBM interface defaults. Scan a bar code below after setting defaults and before configuring the digital scanner. Ignore Beep The host can send a beep request to the digital scanner. When this parameter is enabled, the request is not sent to the attached digital scanner. All directives are still acknowledged to the IBM RS485 host as if it were processed. *Disable Enable 9-6 Symbol DS6878 Product Reference Guide Ignore Bar Code Configuration The host has the ability to enable/disable code types. When this parameter is enabled, the request is not sent to the attached digital scanner. All directives are still acknowledged to the IBM RS485 host as if it were processed. *Disable Enable Chapter 10 Wand Emulation Interface Introduction This chapter provides instructions for programming the cradle to interface with a wand emulation host. This mode is used whenever wand emulation communication is needed. The digital scanner cradle connects either to an external wand decoder or to a decoder integrated in a portable terminal or Point-of-Sale (POS) terminal. In this mode the digital scanner emulates the signal of a digital wand to make it “readable” by a wand decoder. Throughout the programming bar code menus, default values are indicated with asterisks (*). * Indicates Default *Transmit Unknown Characters Feature/Option 10 - 2 Symbol DS6878 Product Reference Guide Connecting Using Wand Emulation NOTE See Chapter 4, Radio Communications for information about digital scanner/cradle pairing and wireless communication The digital scanner must be connected to the cradle for the host parameter setting to take effect. When the digital scanner is not connected to a cradle, and a host parameter bar code is scanned, a long low/long high beep sequence sounds. To perform Wand Emulation, connect the cradle to a portable data terminal, or a controller which collects the wand data and interprets it for the host. Wand Port Interface Cable Mobile Computer Figure 10-1 Wand Emulation Connection To connect the Wand Emulation interface: 1. Attach the modular connector of the Wand Emulation interface cable to the host port on the bottom of the digital scanner cradle (see Connecting the Cradle on page 1-6). 2. Connect the other end of the Wand Emulation interface cable to the wand port on the mobile computer or controller. 3. Select the Wand Emulation host type by scanning the appropriate bar code from Wand Emulation Host Types on page 10-4. 4. To modify any other parameter options, scan the appropriate bar codes in this chapter. NOTE Interface cables vary depending on configuration. The connectors illustrated in Figure 10-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the cradle remain the same. If a power supply is used, disconnect the power supply before changing host cables or the cradle may not recognize the new host. CAUTION Connect the cradle to a 5 volt decoder only. Connecting the cradle to a 12 volt decoder can damage the digital scanner and invalidate the warranty. Wand Emulation Interface 10 - 3 Wand Emulation Parameter Defaults Table 10-1 lists the defaults for Wand Emulation host types. To change any option, scan the appropriate bar code(s) provided in Wand Emulation Host Parameters beginning on page 10-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters. Table 10-1 Wand Emulation Default Table Parameter Default Page Number Wand Emulation Host Parameters Wand Emulation Host Types Symbol OmniLink Interface Controller1 10-4 Leading Margin 80 msec 10-5 Polarity Bar High/Margin Low 10-6 Ignore Unknown Characters Send 10-6 Convert All Bar Codes to Code 39 Disable 10-7 Convert Code 39 to Full ASCII Disable 10-8 1User selection is required to configure this interface and this is the most common selection. 10 - 4 Symbol DS6878 Product Reference Guide Wand Emulation Host Parameters Wand Emulation Host Types Select a Wand Emulation host by scanning one of the bar codes below. Symbol OmniLink Interface Controller1 Symbol PDT Terminal (MSI) Symbol PTC Terminal (Telxon) NOTE 1User selection is required to configure this interface and this is the most common selection. Wand Emulation Interface 10 - 5 Leading Margin (Quiet Zone) Scan a bar code below to select a leading margin duration. A leading margin is the time that precedes the first bar of the scan, (in milliseconds). The minimum allowed value is 80 msec and the maximum is 250 msec. This parameter accommodates older wand decoders which cannot handle short leading margins. NOTE 250 msec is the maximum value that this parameter can attain, however, 200 msec is sufficient. *80 msec 140 msec 200 msec 10 - 6 Symbol DS6878 Product Reference Guide Polarity Scan a bar code below to select the polarity required by the decoder. Polarity determines how the cradle's Wand Emulation interface creates the Digitized Bar code Pattern (DBP). DBP is a digital signal that represents the scanned bar code. Different decoders expect the DBP to be in a certain format. The DBP either has the "highs" represent bars and the "lows" represent spaces (margins), or the "highs" represent spaces (margins) and the "lows" represent bars. *Bar High/Margin Low Bar Low/Margin High Ignore Unknown Characters Unknown characters are characters the host does not recognize. When Send Bar Codes With Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound on the digital scanner. When Do Not Send Bar Codes With Unknown Characters is selected, bar codes containing at least one unknown character are not sent to the host, and the digital scanner emits an error beep. *Send Bar Codes With Unknown Characters Do Not Send Bar Codes With Unknown Characters Wand Emulation Interface 10 - 7 Convert All Bar Codes to Code 39 By default, the Wand Emulation interface sends data to the attached host in the same symbology that was decoded. This can be a problem for customers with older systems that do not recognize newer symbologies (for example, GS1 DataBar). Enabling this parameter ignores the original symbology decoded, and outputs the data as if it were a Code 39 bar code. Any lowercase characters in the original data stream are transmitted as uppercase characters. This also allows ADF rules. If Ignore Unknown Characters is enabled, any characters that do not have a corresponding character in the Code 39 symbology set are replaced by a space. If Ignore Unknown Characters is disabled, if any characters that do not have a corresponding character are encountered, the digital scanner emits an error beep and no data is transmitted. NOTE ADF Note: By default, the Wand Emulation interface does not allow scanned data to be processed by ADF rules. Enabling this parameter has the side effect of allowing the scanned data to be processed by the ADF rules (see Chapter 15, Advanced Data Formatting). Enable Convert to Code 39 for Wand Host *Disable Convert to Code 39 for Wand Host 10 - 8 Symbol DS6878 Product Reference Guide Convert Code 39 to Full ASCII By default, any characters that do not have a corresponding character in the Code 39 symbology set are replaced by a space. If this parameter is enabled, the data sent to the wand interface is encoded in Code 39 Full ASCII. This setting requires that the host be able to interpret Code 39 Full ASCII data. This setting applies only if Convert to Code 39 is also enabled. *Disable Code 39 Full ASCII Conversion Enable Code 39 Full ASCII Conversion Chapter 11 Scanner Emulation Interface This chapter provides instructions for programming the cradle to interface with a digital scanner emulation host. With digital scanner emulation, the cradle connects either to an external decoder or to a decoder integrated in a portable terminal or Point-of-Sale (POS) terminal. Throughout the programming bar code menus, default values are indicated with asterisks (*). * Indicates Default *Parameter Process and Pass-Through Feature/Option 11 - 2 Symbol DS6878 Product Reference Guide Connecting Using Scanner Emulation NOTE See Chapter 4, Radio Communications for information about scanner/cradle pairing and wireless communication The digital scanner must be connected to the cradle for the host parameter setting to take effect. When the digital scanner is not connected to a cradle, and a host parameter bar code is scanned, a long low/long high beep sequence sounds. To perform Scanner Emulation, connect the cradle to a mobile computer, or a controller which collects the data and interprets it for the host. Interface Cable Host Port Connector Figure 11-1 Scanner Emulation Connection To connect the Scanner Emulation interface: 1. Attach the modular connector of the Scanner Emulation interface cable to the host port on the bottom of the digital scanner cradle (see Connecting the Cables to the Cradle on page 1-6). 2. Connect the other end of the Scanner Emulation interface cable to the digital scanner port on the mobile computer or controller. 3. Scan the Scanner Emulation host bar code from Scanner Emulation Host on page 11-3 to enable the Scanner Emulation host interface. 4. To modify any other parameter options, scan the appropriate bar codes in this chapter. NOTE Interface cables vary depending on configuration. The connectors illustrated in Figure 11-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the cradle remain the same. If a power supply is used, disconnect the power supply before changing host cables or the cradle may not recognize the new host. CAUTION Connect the cradle to a 5 volt decoder only. Connecting the cradle to a 12 volt decoder can damage the digital scanner and invalidate the warranty. Scanner Emulation Interface 11 - 3 Scanner Emulation Parameter Defaults Table 11-1 lists the defaults for the Scanner Emulation host. To change any option, scan the appropriate bar code(s) provided in the Scanner Emulation Host Parameters section beginning on page 11-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters. Table 11-1 Scanner Emulation Default Table Parameter Default Page Number Beep Style Beep on Successful Transmit 11-4 Parameter Pass-Through Parameter Process and Pass Through 11-5 Convert Newer Code Types Convert Newer Code Types 11-6 Module Width 20 µs 11-6 Convert All Bar Codes to Code 39 Do Not Convert Bar Codes to Code 39 11-7 Code 39 Full ASCII Conversion Disable 11-7 Transmission Timeout 3 sec 11-8 Ignore Unknown Characters Ignore Unknown Characters 11-9 Leading Margin 2 ms 11-9 Check for Decode LED Check for Decode LED 11-10 1User selection is required to configure this interface and this is the most common selection. Scanner Emulation Host Scan the bar code below to enable the Scanner Emulation host. Undecoded Scanner Emulation Host 11 - 4 Symbol DS6878 Product Reference Guide Scanner Emulation Host Parameters Beep Style The Scanner Emulation host supports three beep styles. • Beep On Successful Transmit: The digital scanner beeps when the attached decoder issues the decode signal to the digital scanner, so the digital scanner and the attached decoder beep at the same time. • Beep At Decode Time: The digital scanner beeps upon decode. This results in a double beep sequence from most decoders, since the digital scanner beeps, and the decoder beeps (at a different frequency) when it successfully decodes the output. • Do Not Beep: Only the attached decoder issues the decode beep. *Beep On Successful Transmit Beep At Decode Time Do Not Beep Scanner Emulation Interface 11 - 5 Parameter Pass-Through The Scanner Emulation host can process parameter bar code messages and send them to the attached decoder. In this way, customers using Symbol compliant decoders can control the behavior of the entire system by scanning the necessary parameters only once. For example, to enable D 2 of 5, scan the D 2 of 5 Enable parameter bar code. The digital scanner and the attached decoder both process the parameter. *Parameter Process and Pass-Through Parameter Process Only 11 - 6 Symbol DS6878 Product Reference Guide Convert Newer Code Types The digital scanner supports a variety of code types that are not decodable by attached decoder systems. To allow compatibility in these environments, the digital scanner converts these code types to more commonly decodable symbologies, as per the following chart. Symbologies not listed on this chart are transmitted normally. Scan this code type: Transmitted as: Code 11 Code 39 Chinese 2 of 5 Code 39 GS1 DataBar (14, Limited, and Expanded) Code 128 Coupon Code Code 128 When decoding these code types with this parameter disabled, the digital scanner issues Convert Error beeps and transmits no data. *Convert Newer Code Types Reject Newer Code Types Module Width The standard module width is 20 µs. For an extremely slow decoder system, select 50 µs Module Width. *20 µs Module Width 50 µs Module Width Scanner Emulation Interface 11 - 7 Convert All Bar Codes to Code 39 Scan the bar code below to enable or disable the conversion of all bar code data to Code 39. *Do Not Convert Bar Codes To Code 39 Convert All To Code 39 Code 39 Full ASCII Conversion By default, any characters that do not have a corresponding character in the Code 39 symbology set are replaced by a space. If this parameter is enabled, the data sent to the Scanner Emulation host is encoded in Code 39 Full ASCII. The host must be able to interpret Code 39 Full ASCII data. This setting applies only if Convert to Code 39 is also enabled. *Disable Convert Code 39 To Full ASCII Enable Convert Code 39 To Full ASCII 11 - 8 Symbol DS6878 Product Reference Guide Transmission Timeout The Scanner Emulation host transmits bar code data to the attached decoder and waits for the decoder to assert the Decode signal, indicating successful transmission. If, after a specified amount of time, the Decode signal is not asserted (indicating that the attached decoder has not successfully received the bar code data), the digital scanner issues transmit error beeps. Scan a bar code below to select the desired transmission timeout. *3 Second Transmission Timeout 4 Second Transmission Timeout 5 Second Transmission Timeout 10 Second Transmission Timeout 30 Second Transmission Timeout Scanner Emulation Interface 11 - 9 Ignore Unknown Characters Unknown characters are characters the decoder does not recognize. When Ignore Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound. When Convert Error on Unknown Characters is selected, bar codes containing at least one unknown character are not sent to the decoder, and a convert error beep sounds. *Ignore Unknown Characters Convert Error On Unknown Characters Leading Margin Scan a bar code below to select a leading margin duration. 1 ms Leading Margin *2 ms Leading Margin 3 ms Leading Margin 11 - 10 Symbol DS6878 Product Reference Guide Leading Margin (continued) 5 ms Leading Margin 10 ms Leading Margin Check For Decode LED The attached decoder normally asserts the Decode line to signal to the Scanner Emulation host that it successfully decoded the transmitted bar code. Some decoders, however, do not assert the Decode signal. In this case, the digital scanner emits transmit error beeps to indicate that the bar code was not successfully transmitted. Scan the Ignore Decode LED bar code to disable the Transmit Error beeps. *Check For Decode LED Ignore Decode LED Chapter 12 123Scan2 Introduction 123Scan² is an easy-to-use, PC-based software tool that enables rapid and easy customized setup of Symbol scanners by Motorola. 123Scan² uses a wizard tool to guide users through a streamlined set up process. Settings are saved in a configuration file that can be distributed via e-mail, electronically downloaded via a USB cable, or used to generate a sheet of scannable programming bar codes. Additionally 123Scan² can upgrade scanner firmware, check online to enable support for newly released products, generate a collection of multi-setting bar codes if the number of settings is very large, stage large number of scanners simultaneously, generate reports with asset tracking information and create custom products. Communication with 123Scan2 To communicate with the 123Scan² program which runs on a host computer running a Windows XP SP2 or Windows Vista operating system, use a USB cable to connect the scanner cradle to the host computer (see USB Connection on page 6-2). 123Scan2 Requirements • Host computer with Windows XP SP2 or Windows Vista • Scanner • Cradle • USB cable. 12 - 2 Symbol DS6878 Product Reference Guide For more information on123Scan², go to: http://www.motorola.com/123Scan2 To download 123Scan² software and access the Help file integrated in the utility, go to: http://support.symbol.com/support/product/123Scan2.html Chapter 13 OCR Programming Introduction This chapter describes how to set up the digital scanner for OCR programming. The digital scanner can read 6 to 60 point OCR typeface. It supports font types OCR-A, OCR-B, MICR-E13B, and US Currency Serial Number. OCR is not as secure as a bar code. To decrease OCR misdecodes and speed OCR reading, set an accurate OCR template and character subset, and use a check digit. All OCR fonts are disabled by default. Enabling OCR can slow bar code decoding. Enabling more than one OCR font could also slow OCR decoding and impact OCR decoding accuracy. Throughout the programming bar code menus, asterisks (*) indicate default values. * Indicates Default NOTE *Disable OCR-A Feature/Option Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces are not merging. 13 - 2 Symbol DS6878 Product Reference Guide OCR Parameter Defaults Table 13-1 lists the defaults for OCR parameters. To change any option, scan the appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 13-3. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters. Table 13-1 OCR Programming Default Table Parameter Parameter Number Default Page Number OCR Programming Parameters OCR-A F1h A8h Disable 13-3 OCR-A Variant F1h ACh Full ASCII 13-3 OCR-B F1h A9h Disable 13-5 OCR-B Variant F1h ADh Full ASCII 13-6 MICR E13B F1h AAh Disable 13-9 US Currency F1h ABh Disable 13-10 OCR Orientation F1h AFh 0o 13-10 OCR Lines F1h B3h 13-12 OCR Minimum Characters F1h B1h 13-12 OCR Maximum Characters F1h B2h 100 13-13 OCR Security Level F1h 2Ah 80 13-13 OCR Subset F1h AEh Selected font variant 13-14 OCR Quiet Zone F1h B7h 50 13-14 OCR Bright Illumination F1h BDh Disable 13-15 OCR Template F1h 23h 54R 13-16 OCR Check Digit Modulus F1h B0h 13-25 OCR Check Digit Multiplier F1h BCh 121212121212 13-26 OCR Check Digit Validation F1h B6h None 13-27 OCR Programming 13 - 3 OCR Programming Parameters Enable/Disable OCR-A Parameter # F1h A8h To enable or disable OCR-A, scan one of the following bar codes. Enable OCR-A *Disable OCR-A OCR-A Variant Parameter # F1 ACh Font variant sets a processing algorithm and default character subset for the given font. To choose a variant, scan one of the following bar codes. Selecting the most appropriate font variant optimizes performance and accuracy. OCR-A supports the following variants: • OCR-A Full ASCII !"#$()*+,-./0123456789<>ABCDEFGHIJKLMNOPQRSTUVWXYZ\^ • OCR-A Reserved 1 $*+-./0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ • OCR-A Reserved 2 $*+-./0123456789<>ABCDEFGHIJKLMNOPQRSTUVWXYZ • OCR-A Banking -0123456789<> Special banking characters output as the following representative characters: outputs as f outputs as c outputs as h NOTE Enable OCR-A before setting this parameter. If disabling OCR-A, set the variant to its default (OCR-A Full ASCII). 13 - 4 Symbol DS6878 Product Reference Guide OCR-A Variant (continued) *OCR-A Full ASCII (00h) OCR-A Reserved 1 (01h) OCR-A Reserved 2 (02h) OCR-A Banking (03h) OCR Programming 13 - 5 Enable/Disable OCR-B Parameter # F1h A9h To enable or disable OCR-B, scan one of the following bar codes. Enable OCR-B *Disable OCR-B 13 - 6 Symbol DS6878 Product Reference Guide OCR-B Variant Parameter # F1 ADh OCR-B has the following variants. Selecting the most appropriate font variant affects performance and accuracy. • OCR-B Full ASCII !#$%()*+,-./0123456789<>ABCDEFGHIJKLMNOPQRSTUVWXYZ^|Ñ • OCR-B Banking #+-0123456789<>JNP| • OCR-B Limited +,-./0123456789<>ACENPSTVX • OCR-B Travel Document Version 1 (TD1) 3-Line ID Cards -0123456789BCEINPSXz • OCR-B ISBN 10 or 13-Digit Book Numbers -0123456789>BCEINPSXz • OCR-B Travel Document Version 2 (TD2) 2-Line ID Cards -0123456789 >789 <<789 Alpha or Fill (F) The data validator accepts any alpha or fill character in this position. Template Valid data Valid data Invalid data AAAFF ABCXY LMN>> ABC<5 Required Space ( ) Space When this option appears in the template string, the template accepts a space if present. Optional characters are not allowed as the first character(s) in a field of like characters. Template Valid data Invalid data 99 99 12 34 67891 13 - 20 Symbol DS6878 Product Reference Guide Optional Small Special (.) When this option appears in the template string, the data validator accepts a special character if present. Optional characters are not allowed as the first character(s) in a field of like characters. Small special characters are - , and . Template Valid data Valid data Invalid data AA.99 MN.35 XY98 XYZ12 Other Template Operators These template operators assist in capturing, delimiting, and formatting scanned OCR data. Literal String (" and +) “ Use either of these delimiting characters surrounding characters from the alphanumeric keyboard in Chapter 15, Advanced Data Formatting to define a literal string within a template that must be present in scanned OCR data. There are two characters used to delimit required literal strings; if one of the delimiter characters is present in the desired literal string, use the other delimiter. Template Valid data Invalid data "35+BC" 35+BC AB+22 OCR Programming 13 - 21 New Line (E) To create a template of multiple lines, add E between the template of each single line. Template 999EAAAA Valid data Valid data Invalid data 321 987 XYZW BCAD ZXYW 12 String Extract (C) This operator combined with others defines a string of characters to extract from the scanned data. The string extract is structured as follows: CbPe Where: • C is the string extract operator • b is the string begin delimiter • P is the category (one or more numeric or alpha characters) describing the string representation • e is the string end delimiter Values for b and e can be any scannable character. They are included in the output stream. Template Incoming data Output C>A> XQ3>ABCDE> >ABCDE> ->ATHRUZ>123 >ATHRUZ> 1ABCZXYZ No Output 13 - 22 Symbol DS6878 Product Reference Guide Ignore to End of Field (D) This operator causes all characters after a template to be ignored. Use this as the last character in a template expression. Examples for the template 999D: Template Incoming data Output 999D 123-PED 123 357298 357 193 193 Skip Until (P1) This operator allows skipping over characters until a specific character type or a literal string is detected. It can be used in two ways: P1ct Where: • P1 is the Skip Until operator • c is the type of character that triggers the start of output • t is one or more template characters P1"s"t Where: • P1 is the Skip Until operator • "s" is one or more literal string characters (see Literal String (" and +) on page 13-20) that trigger the start of output • t is one or more template characters OCR Programming 13 - 23 The trigger character or literal string is included in output from a Skip Until operator, and the first character in the template should accommodate this trigger. Template Incoming data Output P1"PN"AA999 123PN9876 PN9876 PN1234 PN1234 X-PN3592 PN3592 Skip Until Not (P0) This operator allows skipping over characters until a specific character type or a literal string is not matched in the output stream. It can be used in two ways: P0ct Where: • P0 is the Skip Until Not operator • c is the type of character that triggers the start of output • t is one or more template characters P0"s"t Where: • P0 is the Skip Until Not operator • "s" is one or more literal string characters (see Literal String (" and +) on page 13-20) that trigger the start of output • t is one or more template characters 13 - 24 Symbol DS6878 Product Reference Guide The trigger character or literal string is not included in output from a Skip Until Not operator. Template Incoming data Output P0A9999 BPN3456 3456 PN1234 PN1234 5341 5341 Template Incoming data Output P0"PN"9999 PN3456 3456 5341 5341 PNPN7654 7654 Repeat Previous (R) This operator allows a template character to repeat one or more times, allowing the capture of variable-length scanned data. The following examples capture two required alpha characters followed by one or more required digits: Template Incoming data Output AA9R AB3 AB3 PN12345 PN12345 32RM52700 No output Scroll Until Match (S) This operator steps through scanned data one character at a time until the data matches the template. Template Incoming data Output S99999 AB3 No Output PN12345 12345 32RM52700 52700 OCR Programming 13 - 25 Template Examples Following are sample templates with descriptions of valid data for each definition. Field Definition Description "M"99977 M followed by three digits and two optional digits. "X"997777"X" X followed by two digits, four optional digits, and an X. 9959775599 Two digits followed by any character, a digit, two optional digits, any two characters, and two digits. A55"-"999"-"99 A letter followed by two characters, a dash, three digits, a dash, and two digits. 33A"."99 Two alphanumeric characters followed by a letter, a period, and two digits. 999992991 Five digits followed by an optional alpha, two digits, and an optional alphanumeric. "PN98" Literal field - PN98 OCR Check Digit Modulus Parameter # F1h B0h This option sets OCR module check digit calculation. The check digit is the last digit (in the rightmost position) in an OCR string and improves the accuracy of the collected data. The check digit is the end product of a calculation made on the incoming data. For check digit calculation, for example Modulus 10, alpha and numeric characters are assigned numeric weights (see OCR Check Digit Multiplier on page 13-26). The calculation is applied to the character weights and the resulting check digit is added to the end of the data. If the incoming data does not match the check digit, the data is considered corrupt. The selected check digit option does not take effect until you set OCR Check Digit Validation. To choose the Check Digit Modulus, such as 10 for modulo 10, scan the following bar code, then scan a three-digit number from 001 to 099 representing the check digit using the numeric keypad in Chapter 15, Advanced Data Formatting. The default is 1. OCR Check Digit 13 - 26 Symbol DS6878 Product Reference Guide OCR Check Digit Multiplier Parameter # F1h BCh This option sets OCR check digit multipliers for the character positions. For check digit validation, each character in scanned data has an equivalent weight used in the check digit calculation. DS9808 OCR ships with the following weight equivalents: 0=0 A = 10 K = 20 U = 30 1=1 B = 11 L = 21 V = 31 2=2 C = 12 M = 22 W = 32 3=3 D = 13 N = 23 X = 33 4=4 E = 14 O = 24 Y = 34 5=5 F = 15 P = 25 Z = 35 6=6 G = 16 Q = 26 Space = 0 7=7 H = 17 R = 27 8=8 I = 18 S = 28 9=9 J = 19 T = 29 All other characters are equivalent to one (1). You can define the multiplier string if it is different from the default. 121212121212 (default) 123456789A (for ISBN, Product Add Right to Left. See OCR Check Digit Validation on page 13-27) For example: ISBN Multiplier 10 Product 18 40 12 27 18 Product add 0+ 18+ 0+ 7+ 6+ 40+ 12+ 27+ 18+ 4= 132 ISBN uses modulo 11 for its check digit. In this case, 132 is divisible by 11, so it passes the check digit. To set the check digit multiplier, scan the following bar code, then scan numbers and letters to form the multiplier string from the alphanumeric keyboard in Chapter 15, Advanced Data Formatting. Then scan End of Message in the Chapter 15, Advanced Data Formatting. OCR Check Digit Multiplier OCR Programming 13 - 27 OCR Check Digit Validation Parameter # F1h B6h Use OCR Check Digit Validation to protect against scanning errors by applying a check digit validation scheme. The following is a list of options. None No check digit validation, indicating no check digit is applied. This is the default. *No Check Digit (00h) Product Add Left to Right Each character in the scanned data is assigned a numeric value (see OCR Check Digit Multiplier on page 13-26). Each digit representing a character in the scanned data is multiplied by its corresponding digit in the multiplier, and the sum of these products is computed. The check digit passes if this sum modulo Check Digit Modulus is zero. Example: Scanned data numeric value is 132456 (check digit is 6) Check digit multiplier string is 123456 Digit Multiplier Product Product add 1+ 6+ 6+ 16 16+ 25 25+ 36 36= 90 The Check Digit Modulus is 10. It passes because 90 is divisible by 10 (the remainder is zero). Product Add Left to Right (03h) 13 - 28 Symbol DS6878 Product Reference Guide Product Add Right to Left Each character in the scanned data is assigned a numeric value (see OCR Check Digit Multiplier on page 13-26). The check digit multiplier is reversed in order. Each value representing a character in the scanned data is multiplied by its corresponding digit in the reversed multiplier, resulting in a product for each character in the scanned data. The sum of these products is computed. The check digit passes if this sum modulo Check Digit Modulus is zero. Example: Scanned data numeric value is 132459 (check digit is 9) Check digit multiplier string is 123456 Digit Multiplier Product Product add 6+ 15 15+ 8+ 12 12+ 10 10+ 9= 60 The Check Digit Modulus is 10. It passes because 60 is divisible by 10 (the remainder is 0). Product Add Right to Left (01h) Digit Add Left to Right Each character in the scanned data is assigned a numeric value (see OCR Check Digit Multiplier on page 13-26). Each value representing a character in the scanned data is multiplied by its corresponding digit in the multiplier, resulting in a product for each character in the scanned data. The sum of each individual digit in all of the products is then calculated. The check digit passes if this sum modulo Check Digit Modulus is zero. Example: Scanned data numeric value is 132456 (check digit is 6) Check digit multiplier string is 123456 Digit Multiplier Product Digit add 1+ 6+ 6+ 16 1+6+ 25 2+5+ 36 3+6= 36 The Check Digit Modulus is 12. It passes because 36 is divisible by 12 (the remainder is 0). Digit Add Left to Right (04h) OCR Programming 13 - 29 Digit Add Right to Left Each character in the scanned data is assigned a numeric value (see OCR Check Digit Multiplier on page 13-26). The check digit multiplier is reversed in order. Each value representing a character in the scanned data is multiplied by its corresponding digit in the reversed multiplier, resulting in a product for each character in the scanned data. The sum of each individual digit in all of the products is then calculated. The check digit passes if this sum modulo Check Digit Modulus is zero. Example: Scanned data numeric value is 132456 (check digit is 6) Check digit multiplier string is 123456 Digit Multiplier Product Digit add 6+ 15 1+5+ 8+ 12 1+2+ 10 1+0+ 6= 30 The Check Digit Modulus is 10. It passes because 30 is divisible by 10 (the remainder is 0). Digit Add Right to Left (02h) 13 - 30 Symbol DS6878 Product Reference Guide Product Add Right to Left Simple Remainder Each character in the scanned data is assigned a numeric value (see OCR Check Digit Multiplier on page 13-26). The check digit multiplier is reversed in order. Each value representing a character in the scanned data is multiplied by its corresponding digit in the reversed multiplier, resulting in a product for each character in the scanned data. The sum of these products except for the check digit's product is computed. The check digit passes if this sum modulo Check Digit Modulus is equal to the check digit's product. Example: Scanned data numeric value is 122456 (check digit is 6) Check digit multiplier string is 123456 Digit Multiplier Product Product add 6+ 10 10+ 8+ 12 12+ 10 10= 46 The Check Digit Modulus is 10. It passes because 46 divided by 10 leaves a remainder of 6. Product Add Right to Left Simple Remainder (05h) OCR Programming 13 - 31 Digit Add Right To Left Simple Remainder Each character in the scanned data is assigned a numeric value (see OCR Check Digit Multiplier on page 13-26). The check digit multiplier is reversed in order. Each value representing a character in the scanned data is multiplied by its corresponding digit in the reversed multiplier, resulting in a product for each character in the scanned data. The sum of each individual digit in all of the products except for the check digit's product is then calculated. The check digit passes if this sum modulo Check Digit Modulus is equal to the check digit's product. Example: Scanned data numeric value is 122459 (check digit is 6) Check digit multiplier string is 123456 Digit Multiplier Product Digit add 6+ 10 1+0+ 8+ 12 1+2+ 10 1+0= 19 The Check Digit Modulus is 10. It passes because 19 divided by 10 leaves a remainder of 9. Digit Add Right to Left Simple Remainder (06h) Health Industry - HIBCC43 This is the health industry module 43 check digit standard. Health Industry - HIBCC43 (09h) 13 - 32 Symbol DS6878 Product Reference Guide Chapter 14 Symbologies Introduction This chapter describes symbology features and provides programming bar codes for selecting these features. Before programming, follow the instructions in Chapter 1, Getting Started. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the digital scanner powers down. NOTE Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces do not merge. Select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host. To return all features to default values, scan the Set Default Parameter on page 4-4. Throughout the programming bar code menus, asterisks (*) indicate default values. * Indicates Default *Enable UPC-A (01h) Feature/Option Option Hex Value Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to transmit bar code data without the UPC-A check digit, simply scan the Do Not Transmit UPC-A Check Digit bar code under Transmit UPC-A Check Digit on page 14-14. The digital scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Set Length(s) for D 2 of 5 require scanning several bar codes. See the individual parameter, such as Set Length(s) for D 2 of 5, for this procedure. 14 - 2 Symbol DS6878 Product Reference Guide Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter. Symbology Parameter Defaults Table 14-1 lists the defaults for all symbologies parameters. To change the default values, scan the appropriate bar codes in this guide. These new values replace the standard default values in memory. To recall the default parameter values, scan the Set Default Parameter on page 4-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, and miscellaneous default parameters. Table 14-1 Parameter Defaults Parameter Parameter Number Default Page Number UPC/EAN UPC-A 01h Enable 14-7 UPC-E 02h Enable 14-7 UPC-E1 0Ch Disable 14-8 EAN-8/JAN 8 04h Enable 14-8 EAN-13/JAN 13 03h Enable 14-9 Bookland EAN 53h Disable 14-9 Decode UPC/EAN/JAN Supplementals (2 and 5 digits) 10h Ignore 14-10 User-Programmable Supplementals Supplemental 1: Supplemental 2: F1h 43h F1h 44h UPC/EAN/JAN Supplemental Redundancy 50h 10 14-13 Decode UPC/EAN/JAN Supplemental AIM ID F1h A0h Combined 14-14 Transmit UPC-A Check Digit 28h Enable 14-14 Transmit UPC-E Check Digit 29h Enable 14-15 Transmit UPC-E1 Check Digit 2Ah Enable 14-15 UPC-A Preamble 22h System Character 14-16 UPC-E Preamble 23h System Character 14-17 UPC-E1 Preamble 24h System Character 14-18 Convert UPC-E to A 25h Disable 14-19 14-13 Symbologies 14 - 3 Table 14-1 Parameter Defaults (Continued) Parameter Parameter Number Default Page Number Convert UPC-E1 to A 26h Disable 14-19 EAN-8/JAN-8 Extend 27h Disable 14-20 Bookland ISBN Format F1h 40h ISBN-10 14-21 UCC Coupon Extended Code 55h Enable 14-22 ISSN EAN F1h 69h Disable 14-22 Code 128 08h Enable 14-23 Set Length(s) for Code 128 D1h, D2h Any Length 14-23 GS1-128 (formerly UCC/EAN-128) 0Eh Enable 14-24 ISBT 128 54h Enable 14-25 ISBT Concatenation F1h 41h Disable 14-26 Check ISBT Table F1h 42h Enable 14-27 ISBT Concatenation Redundancy DFh 10 14-27 Code 39 00h Enable 14-28 Trioptic Code 39 0Dh Disable 14-28 Convert Code 39 to Code 32 (Italian Pharmacy Code) 56h Disable 14-29 Code 32 Prefix E7h Disable 14-29 Set Length(s) for Code 39 12h, 13h 2 to 55 14-30 Code 39 Check Digit Verification 30h Disable 14-31 Transmit Code 39 Check Digit 2Bh Disable 14-31 Code 39 Full ASCII Conversion 11h Disable 14-32 Buffer Code 39 71h Disable 14-32 Code 93 09h Disable 14-35 Set Length(s) for Code 93 1Ah, 1Bh 4 to 55 14-35 Code 11 0Ah Disable 14-37 Set Lengths for Code 11 1Ch, 1Dh 4 to 55 14-37 Code 11 Check Digit Verification 34h Disable 14-39 Code 128 Code 39 Code 93 Code 11 14 - 4 Symbol DS6878 Product Reference Guide Table 14-1 Parameter Defaults (Continued) Parameter Transmit Code 11 Check Digit(s) Parameter Number Default Page Number 2Fh Disable 14-40 Interleaved 2 of 5 (ITF) 06h Disable 14-40 Set Lengths for I 2 of 5 16h, 17h 14 14-41 I 2 of 5 Check Digit Verification 31h Disable 14-43 Transmit I 2 of 5 Check Digit 2Ch Disable 14-43 Convert I 2 of 5 to EAN 13 52h Disable 14-44 Discrete 2 of 5 05h Disable 14-44 Set Length(s) for D 2 of 5 14h, 15h 12 14-45 Codabar 07h Disable 14-47 Set Lengths for Codabar 18h, 19h 5 to 55 14-47 CLSI Editing 36h Disable 14-49 NOTIS Editing 37h Disable 14-49 MSI 0Bh Disable 14-50 Set Length(s) for MSI 1Eh, 1Fh 4 to 55 14-50 MSI Check Digits 32h One 14-52 Transmit MSI Check Digit 2Eh Disable 14-52 MSI Check Digit Algorithm 33h Mod 10/Mod 10 14-53 F0h 98h Disable 14-53 Matrix 2 of 5 F1h 6Ah Disable 14-54 Matrix 2 of 5 Lengths F1h 6Bh F1h 6Ch 1 Length - 14 14-55 Matrix 2 of 5 Redundancy F1h 6Dh Disable 14-56 Matrix 2 of 5 Check Digit F1h 6Eh Disable 14-56 Transmit Matrix 2 of 5 Check Digit F1h 6Fh Disable 14-57 Interleaved 2 of 5 (ITF) Discrete 2 of 5 (DTF) Codabar (NW - 7) MSI Chinese 2 of 5 Chinese 2 of 5 Matrix 2 of 5 Symbologies 14 - 5 Table 14-1 Parameter Defaults (Continued) Parameter Parameter Number Default Page Number Korean 3 of 5 Korean 3 of 5 F1h 45h Disable 14-57 Inverse 1D F1h 4Ah Regular 14-58 US Postnet 59h Disable 14-59 US Planet 5Ah Disable 14-59 Transmit US Postal Check Digit 5Fh Enable 14-60 UK Postal 5Bh Disable 14-60 Transmit UK Postal Check Digit 60h Enable 14-61 Japan Postal F0h 22h Disable 14-61 Australian Postal F0h 23h Disable 14-62 Netherlands KIX Code F0h 46h Disable 14-62 USPS 4CB/One Code/Intelligent Mail F1h 50h Disable 14-63 UPU FICS Postal F1h 63h Disable 14-63 GS1 DataBar-14 F0h 52h Disable 14-64 GS1 DataBar Limited F0h 53h Disable 14-64 GS1 DataBar Expanded F0h 54h Disable 14-65 Convert GS1 DataBar to UPC/EAN F0h 8Dh Disable 14-65 Composite CC-C F0h 55h Disable 14-66 Composite CC-A/B F0h 56h Disable 14-66 Composite TLC-39 F0h 73h Disable 14-67 UPC Composite Mode F0h 58h Never Linked 14-67 Composite Beep Mode F0h 8Eh Beep As Each Code Type is Decoded 14-68 GS1-128 Emulation Mode for UCC/EAN Composite Codes F0h ABh Disable 14-68 PDF417 0Fh Enable 14-69 MicroPDF417 E3h Disable 14-69 Postal Codes GS1 DataBar Composite 2D Symbologies 14 - 6 Symbol DS6878 Product Reference Guide Table 14-1 Parameter Defaults (Continued) Parameter Parameter Number Default Page Number Code 128 Emulation 7Bh Disable 14-70 Data Matrix F0h 24h Enable 14-71 Data Matrix Inverse F1h 4Ch Regular 14-71 Maxicode F0h 26h Disable 14-72 QR Code F0h 25h Enable 14-72 QR Inverse F1h 4Bh Regular 14-73 MicroQR F1h 3Dh Enable 14-73 Aztec F1h 3Eh Enable 14-74 Aztec Inverse F1h 4Dh Regular 14-74 Redundancy Level 4Eh 14-75 Security Level 4Dh 14-77 Intercharacter Gap Size F0h 7Dh Normal 14-78 Symbology-Specific Security Levels Report Version 14-78 Macro PDF Flush Macro PDF Buffer 14-79 Abort Macro PDF Entry 14-79 Symbologies 14 - 7 UPC/EAN Enable/Disable UPC-A Parameter # 01h To enable or disable UPC-A, scan the appropriate bar code below. *Enable UPC-A (01h) Disable UPC-A (00h) Enable/Disable UPC-E Parameter # 02h To enable or disable UPC-E, scan the appropriate bar code below. *Enable UPC-E (01h) Disable UPC-E (00h) 14 - 8 Symbol DS6878 Product Reference Guide Enable/Disable UPC-E1 Parameter # 0Ch UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below. NOTE UPC-E1 is not a UCC (Uniform Code Council) approved symbology. Enable UPC-E1 (01h) *Disable UPC-E1 (00h) Enable/Disable EAN-8/JAN-8 Parameter # 04h To enable or disable EAN-8/JAN-8, scan the appropriate bar code below. *Enable EAN-8/JAN-8 (01h) Disable EAN-8/JAN-8 (00h) Symbologies 14 - 9 Enable/Disable EAN-13/JAN-13 Parameter # 03h To enable or disable EAN-13/JAN-13, scan the appropriate bar code below. *Enable EAN-13/JAN-13 (01h) Disable EAN-13/JAN-13 (00h) Enable/Disable Bookland EAN Parameter # 53h To enable or disable Bookland EAN, scan the appropriate bar code below. Enable Bookland EAN (01h) *Disable Bookland EAN (00h) NOTE If you enable Bookland EAN, select a Bookland ISBN Format on page 14-21. Also select either Decode UPC/EAN Supplementals, Autodiscriminate UPC/EAN Supplementals, or Enable 978/979 Supplemental Mode in Decode UPC/EAN/JAN Supplementals on page 14-10. 14 - 10 Symbol DS6878 Product Reference Guide Decode UPC/EAN/JAN Supplementals Parameter # 10h Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN 13+2). The following options are available: • If you select Ignore UPC/EAN with Supplementals, and the digital scanner is presented with a UPC/EAN plus supplemental symbol, the digital scanner decodes UPC/EAN and ignores the supplemental characters. • If you select Decode UPC/EAN with Supplementals, the digital scanner only decodes UPC/EAN symbols with supplemental characters, and ignores symbols without supplementals. • If you select Autodiscriminate UPC/EAN Supplementals, the digital scanner decodes UPC/EAN symbols with supplemental characters immediately. If the symbol does not have a supplemental, the digital scanner must decode the bar code the number of times set via UPC/EAN/JAN Supplemental Redundancy on page 14-13 before transmitting its data to confirm that there is no supplemental. • If you select one of the following Supplemental Mode options, the digital scanner immediately transmits EAN-13 bar codes starting with that prefix that have supplemental characters. If the symbol does not have a supplemental, the digital scanner must decode the bar code the number of times set via UPC/EAN/JAN Supplemental Redundancy on page 14-13 before transmitting its data to confirm that there is no supplemental. The digital scanner transmits UPC/EAN bar codes that do not have that prefix immediately. • Enable 378/379 Supplemental Mode • Enable 978/979 Supplemental Mode NOTE If you select 978/979 Supplemental Mode and are scanning Bookland EAN bar codes, see Enable/Disable Bookland EAN on page 14-9 to enable Bookland EAN, and select a format using Bookland ISBN Format on page 14-21. • Enable 977 Supplemental Mode • Enable 414/419/434/439 Supplemental Mode • Enable 491 Supplemental Mode • Enable Smart Supplemental Mode - applies to EAN-13 bar codes starting with any prefix listed previously. • Supplemental User-Programmable Type 1 - applies to EAN-13 bar codes starting with a 3-digit user-defined prefix. Set this 3-digit prefix using User-Programmable Supplementals on page 14-13. • Supplemental User-Programmable Type 1 and 2 - applies to EAN-13 bar codes starting with either of two 3-digit user-defined prefixes. Set the 3-digit prefixes using User-Programmable Supplementals on page 14-13. • Smart Supplemental Plus User-Programmable 1 - applies to EAN-13 bar codes starting with any prefix listed previously or the user-defined prefix set using User-Programmable Supplementals on page 14-13. • Smart Supplemental Plus User-Programmable 1 and 2 - applies to EAN-13 bar codes starting with any prefix listed previously or one of the two user-defined prefixes set using User-Programmable Supplementals on page 14-13. NOTE To minimize the risk of invalid data transmission, select either to decode or ignore supplemental characters. Symbologies 14 - 11 Decode UPC/EAN/JAN Supplementals (continued) Decode UPC/EAN/JAN Only With Supplementals (01h) *Ignore Supplementals (00h) Autodiscriminate UPC/EAN/JAN Supplementals (02h) Enable 378/379 Supplemental Mode (04h) Enable 978/979 Supplemental Mode (05h) Enable 977 Supplemental Mode (07h) 14 - 12 Symbol DS6878 Product Reference Guide Decode UPC/EAN/JAN Supplementals (continued) Enable 414/419/434/439 Supplemental Mode (06h) Enable 491 Supplemental Mode (08h) Enable Smart Supplemental Mode (03h) Supplemental User-Programmable Type 1 (09h) Supplemental User-Programmable Type 1 and 2 (0Ah) Smart Supplemental Plus User-Programmable 1 (0Bh) Smart Supplemental Plus User-Programmable 1 and 2 (0Ch) Symbologies 14 - 13 User-Programmable Supplementals Supplemental 1: Parameter # F1h 43h Supplemental 2: Parameter # F1h 44h If you selected a Supplemental User-Programmable option from Decode UPC/EAN/JAN Supplementals on page 14-10, select User-Programmable Supplemental 1 to set the 3-digit prefix. Then select the 3 digits using the numeric bar codes beginning onpage D-1. Select User-Programmable Supplemental 2 to set a second 3-digit prefix. Then select the 3 digits using the numeric bar codes beginning onpage D-1. User-Programmable Supplemental 1 User-Programmable Supplemental 2 UPC/EAN/JAN Supplemental Redundancy Parameter # 50h If you selected Autodiscriminate UPC/EAN/JAN Supplementals, this option adjusts the number of times to decode a symbol without supplementals before transmission. The range is from two to thirty times. Five or above is recommended when decoding a mix of UPC/EAN/JAN symbols with and without supplementals. The default is 10. Scan the bar code below to set a decode redundancy value. Next, scan two numeric bar codes in Appendix D, Numeric Bar Codes. Enter a leading zero for single digit numbers. To correct an error or change a selection, scan Cancel on page D-2. UPC/EAN/JAN Supplemental Redundancy 14 - 14 Symbol DS6878 Product Reference Guide UPC/EAN/JAN Supplemental AIM ID Format Parameter # F1h A0h Select an output format when reporting UPC/EAN/JAN bar codes with supplementals with AIM ID enabled: • Separate - UPC/EAN with supplementals transmit as ]E<0 or 4>]E<1 or 2>[supp data] • Combined - EAN-8 with supplementals transmit as ]E4]E<1 or 2>[supp data] All other UPC/EAN with supplementals transmit as ]E3 Separate (00h) *Combined (01h) Transmit UPC-A Check Digit Parameter # 28h The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-A check digit. It is always verified to guarantee the integrity of the data. *Transmit UPC-A Check Digit (01h) Do Not Transmit UPC-A Check Digit (00h) Symbologies 14 - 15 Transmit UPC-E Check Digit Parameter # 29h The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-E check digit. It is always verified to guarantee the integrity of the data. *Transmit UPC-E Check Digit (01h) Do Not Transmit UPC-E Check Digit (00h) Transmit UPC-E1 Check Digit Parameter # 2Ah The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-E1 check digit. It is always verified to guarantee the integrity of the data. *Transmit UPC-E1 Check Digit (01h) Do Not Transmit UPC-E1 Check Digit (00h) 14 - 16 Symbol DS6878 Product Reference Guide UPC-A Preamble Parameter # 22h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-A preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system. No Preamble () (00h) *System Character ( ) (01h) System Character & Country Code (< COUNTRY CODE> ) (02h) Symbologies 14 - 17 UPC-E Preamble Parameter # 23h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-E preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system. No Preamble () (00h) *System Character ( ) (01h) System Character & Country Code (< COUNTRY CODE> ) (02h) 14 - 18 Symbol DS6878 Product Reference Guide UPC-E1 Preamble Parameter # 24h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-E1 preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system. No Preamble () (00h) *System Character ( ) (01h) System Character & Country Code (< COUNTRY CODE> ) (02h) Symbologies 14 - 19 Convert UPC-E to UPC-A Parameter # 25h Enable this to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). Disable this to transmit UPC-E decoded data as UPC-E data, without conversion. Convert UPC-E to UPC-A (Enable) (01h) *Do Not Convert UPC-E to UPC-A (Disable) (00h) Convert UPC-E1 to UPC-A Parameter # 26h Enable this to convert UPC-E1 decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). Disable this to transmit UPC-E1 decoded data as UPC-E1 data, without conversion. Convert UPC-E1 to UPC-A (Enable) (01h) *Do Not Convert UPC-E1 to UPC-A (Disable) (00h) 14 - 20 Symbol DS6878 Product Reference Guide EAN-8/JAN-8 Extend Parameter # 27h Enable this parameter to add five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols. Disable this to transmit EAN-8 symbols as is. Enable EAN/JAN Zero Extend (01h) *Disable EAN/JAN Zero Extend (00h) Symbologies 14 - 21 Bookland ISBN Format Parameter # F1h 40h If you enabled Bookland EAN using Enable/Disable Bookland EAN on page 14-9, select one of the following formats for Bookland data: • Bookland ISBN-10 - The digital scanner reports Bookland data starting with 978 in traditional 10-digit format with the special Bookland check digit for backward-compatibility. Data starting with 979 is not considered Bookland in this mode. • Bookland ISBN-13 - The digital scanner reports Bookland data (starting with either 978 or 979) as EAN-13 in 13-digit format to meet the 2007 ISBN-13 protocol. *Bookland ISBN-10 (00h) Bookland ISBN-13 (01h) NOTE For Bookland EAN to function properly, first enable Bookland EAN using Enable/Disable Bookland EAN on page 14-9, then select either Decode UPC/EAN Supplementals, Autodiscriminate UPC/EAN Supplementals, or Enable 978/979 Supplemental Mode in Decode UPC/EAN/JAN Supplementals on page 14-10. 14 - 22 Symbol DS6878 Product Reference Guide UCC Coupon Extended Code Parameter # 55h Enable this parameter to decode UPC-A bar codes starting with digit ‘5’, EAN-13 bar codes starting with digit ‘99’, and UPC-A/GS1-128 Coupon Codes. UPCA, EAN-13, and GS1-128 must be enabled to scan all types of Coupon Codes. *Enable UCC Coupon Extended Code (01h) Disable UCC Coupon Extended Code (00h) NOTE See UPC/EAN/JAN Supplemental Redundancy on page 14-13 to control autodiscrimination of the GS1-128 (right half) of a coupon code. ISSN EAN Parameter # F1h 69h To enable or disable ISSN EAN, scan the appropriate bar code below. Enable ISSN EAN (01h) *Disable ISSN EAN (00h) Symbologies 14 - 23 Code 128 Enable/Disable Code 128 Parameter # 08h To enable or disable Code 128, scan the appropriate bar code below. *Enable Code 128 (01h) Disable Code 128 (00h) Set Lengths for Code 128 Parameter # L1 = D1h, L2 = D2h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 128 to any length, one or two discrete lengths, or lengths within a specific range. NOTE When setting lengths for different bar code types, enter a leading zero for single digit numbers. • One Discrete Length - Select this option to decode only Code 128 symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 128 symbols with 14 characters, scan Code 128 - One Discrete Length, then scan 1 followed by 4. To correct an error or change the selection, scan Cancel on page D-2. • Two Discrete Lengths - Select this option to decode only Code 128 symbols containing either of two selected lengths. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 128 symbols containing either 2 or 14 characters, select Code 128 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or change the selection, scan Cancel on page D-2. • Length Within Range - Select this option to decode a Code 128 symbol with a specific length range. Select lengths using numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode Code 128 symbols containing between 4 and 12 characters, first scan Code 128 - Length Within Range. Then scan 0, 4, 1, and 2 (enter a leading zero for single digit numbers). To correct an error or change the selection, scan Cancel on page D-2. • Any Length - Select this option to decode Code 128 symbols containing any number of characters within the digital scanner’s capability. 14 - 24 Symbol DS6878 Product Reference Guide Set Lengths for Code 128 (continued) Code 128 - One Discrete Length Code 128 - Two Discrete Lengths Code 128 - Length Within Range *Code 128 - Any Length Enable/Disable GS1-128 (formerly UCC/EAN-128) Parameter # 0Eh To enable or disable GS1-128, scan the appropriate bar code below. *Enable GS1-128 (01h) Disable GS1-128 (00h) Symbologies 14 - 25 Enable/Disable ISBT 128 Parameter # 54h ISBT 128 is a variant of Code 128 used in the blood bank industry. Scan a bar code below to enable or disable ISBT 128. If necessary, the host must perform concatenation of the ISBT data. *Enable ISBT 128 (01h) Disable ISBT 128 (00h) 14 - 26 Symbol DS6878 Product Reference Guide ISBT Concatenation Parameter # F1h 41h Select an option for concatenating pairs of ISBT code types: • If you select Disable ISBT Concatenation, the digital scanner does not concatenate pairs of ISBT codes it encounters. • If you select Enable ISBT Concatenation, there must be two ISBT codes in order for the digital scanner to decode and perform concatenation. The digital scanner does not decode single ISBT symbols. • If you select Autodiscriminate ISBT Concatenation, the digital scanner decodes and concatenates pairs of ISBT codes immediately. If only a single ISBT symbol is present, the digital scanner must decode the symbol the number of times set via ISBT Concatenation Redundancy on page 14-27 before transmitting its data to confirm that there is no additional ISBT symbol. *Disable ISBT Concatenation (00h) Enable ISBT Concatenation (01h) Autodiscriminate ISBT Concatenation (00h) Symbologies 14 - 27 Check ISBT Table Parameter # F1h 42h The ISBT specification includes a table that lists several types of ISBT bar codes that are commonly used in pairs. If you set ISBT Concatenation to Enable, enable Check ISBT Table to concatenate only those pairs found in this table. Other types of ISBT codes are not concatenated. *Enable Check ISBT Table (01h) Disable Check ISBT Table (00h) ISBT Concatenation Redundancy Parameter # DFh If you set ISBT Concatenation to Autodiscriminate, use this parameter to set the number of times the digital scanner must decode an ISBT symbol before determining that there is no additional symbol. Scan the bar code below, then scan two numeric bar codes in Appendix D, Numeric Bar Codes to set a value between 2 and 20. Enter a leading zero for single digit numbers. To correct an error or change a selection, scan Cancel on page D-2. The default is 10. ISBT Concatenation Redundancy 14 - 28 Symbol DS6878 Product Reference Guide Code 39 Enable/Disable Code 39 Parameter # 00h To enable or disable Code 39, scan the appropriate bar code below. *Enable Code 39 (01h) Disable Code 39 (00h) Enable/Disable Trioptic Code 39 Parameter # 0Dh Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges. Trioptic Code 39 symbols always contain six characters. To enable or disable Trioptic Code 39, scan the appropriate bar code below. Enable Trioptic Code 39 (01h) *Disable Trioptic Code 39 (00h) NOTE You cannot enable Trioptic Code 39 and Code 39 Full ASCII simultaneously. Symbologies 14 - 29 Convert Code 39 to Code 32 Parameter # 56h Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32. NOTE Code 39 must be enabled for this parameter to function. Enable Convert Code 39 to Code 32 (01h) *Disable Convert Code 39 to Code 32 (00h) Code 32 Prefix Parameter # E7h Scan the appropriate bar code below to enable or disable adding the prefix character “A” to all Code 32 bar codes. NOTE Convert Code 39 to Code 32 must be enabled for this parameter to function. Enable Code 32 Prefix (01h) *Disable Code 32 Prefix (00h) 14 - 30 Symbol DS6878 Product Reference Guide Set Lengths for Code 39 Parameter # L1 = 12h, L2 = 13h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 39 to any length, one or two discrete lengths, or lengths within a specific range. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options. NOTE When setting lengths for different bar code types, enter a leading zero for single digit numbers. • One Discrete Length - Select this option to decode only Code 39 symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 39 symbols with 14 characters, scan Code 39 - One Discrete Length, then scan 1 followed by 4. To correct an error or change the selection, scan Cancel on page D-2. • Two Discrete Lengths - Select this option to decode only Code 39 symbols containing either of two selected lengths. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 39 symbols containing either 2 or 14 characters, select Code 39 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or change the selection, scan Cancel on page D-2. • Length Within Range - Select this option to decode a Code 39 symbol with a specific length range. Select lengths using numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 - Length Within Range. Then scan 0, 4, 1, and 2 (enter a leading zero for single digit numbers). To correct an error or change the selection, scan Cancel on page D-2. • Any Length - Select this option to decode Code 39 symbols containing any number of characters within the digital scanner’s capability. Code 39 - One Discrete Length Code 39 - Two Discrete Lengths Code 39 - Length Within Range Code 39 - Any Length Symbologies 14 - 31 Code 39 Check Digit Verification Parameter # 30h Enable this feature to check the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm. Only Code 39 symbols which include a modulo 43 check digit are decoded. Enable this feature if the Code 39 symbols contain a Modulo 43 check digit. Enable Code 39 Check Digit (01h) *Disable Code 39 Check Digit (00h) Transmit Code 39 Check Digit Parameter # 2Bh Scan a bar code below to transmit Code 39 data with or without the check digit. Transmit Code 39 Check Digit (Enable) (01h) *Do Not Transmit Code 39 Check Digit (Disable) (00h) NOTE Code 39 Check Digit Verification must be enabled for this parameter to function. 14 - 32 Symbol DS6878 Product Reference Guide Code 39 Full ASCII Conversion Parameter # 11h Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. To enable or disable Code 39 Full ASCII, scan the appropriate bar code below. Enable Code 39 Full ASCII (01h) *Disable Code 39 Full ASCII (00h) NOTE You cannot enable Trioptic Code 39 and Code 39 Full ASCII simultaneously. Code 39 Full ASCII to Full ASCII Correlation is host-dependent, and is therefore described in the ASCII Character Set Table for the appropriate interface. See the ASCII Character Set for USB on page 6-13 or the ASCII Character Set for RS-232 on page 7-19. Code 39 Buffering - Scan & Store Parameter # 71h This feature allows the digital scanner to accumulate data from multiple Code 39 symbols. Selecting the Scan and Store option (Buffer Code 39) temporarily buffers all Code 39 symbols having a leading space as a first character for later transmission. The leading space is not buffered. Decoding a Code 39 symbol with no leading space transmits in sequence all buffered data in a first-in first-out format, plus the “triggering” symbol. See the following pages for further details. Select Do Not Buffer Code 39 to transmit all decoded Code 39 symbols immediately without storing them in the buffer. Symbologies 14 - 33 Code 39 Buffering - Scan & Store (continued) This feature affects Code 39 only. If selecting Buffer Code 39, we recommend configuring the digital scanner to decode Code 39 symbology only. Buffer Code 39 (Enable) (01h) *Do Not Buffer Code 39 (Disable) (00h) While there is data in the transmission buffer, you cannot select Do Not Buffer Code 39. The buffer holds 200 bytes of information. To disable Code 39 buffering when there is data in the transmission buffer, first force the buffer transmission (see Transmit Buffer on page 14-34) or clear the buffer. Buffer Data To buffer data, enable Code 39 buffering and scan a Code 39 symbol with a space immediately following the start pattern. • Unless the data overflows the transmission buffer, the digital scanner issues a low/high beep to indicate successful decode and buffering. (For overflow conditions, see Overfilling Transmission Buffer on page 14-34.) • The digital scanner adds the decoded data excluding the leading space to the transmission buffer. • No transmission occurs. Clear Transmission Buffer To clear the transmission buffer, scan the Clear Buffer bar code below, which contains only a start character, a dash (minus), and a stop character. • The digital scanner issues a short high/low/high beep. • The digital scanner erases the transmission buffer. • No transmission occurs. Clear Buffer NOTE The Clear Buffer contains only the dash (minus) character. In order to scan this command, set Code 39 lengths to include length 1. 14 - 34 Symbol DS6878 Product Reference Guide Transmit Buffer There are two methods to transmit the Code 39 buffer. 1. Scan the Transmit Buffer bar code below, which includes only a start character, a plus (+), and a stop character. 2. The digital scanner transmits and clears the buffer. • The digital scanner issues a low/high beep. Transmit Buffer 3. Scan a Code 39 bar code with a leading character other than a space. • The digital scanner appends new decode data to buffered data. • The digital scanner transmits and clears the buffer. • The digital scanner signals that it transmitted the buffer with a low/high beep. • The digital scanner transmits and clears the buffer. NOTE The Transmit Buffer contains only a plus (+) character. In order to scan this command, set Code 39 lengths to include length 1. Overfilling Transmission Buffer The Code 39 buffer holds 200 characters. If the symbol just read overflows the transmission buffer: • The digital scanner indicates that it rejected the symbol by issuing three long, high beeps. • No transmission occurs. The data in the buffer is not affected. Attempt to Transmit an Empty Buffer If you scan the Transmit Buffer symbol and the Code 39 buffer is empty: • A short low/high/low beep signals that the buffer is empty. • No transmission occurs. • The buffer remains empty. Symbologies 14 - 35 Code 93 Enable/Disable Code 93 Parameter # 09h To enable or disable Code 93, scan the appropriate bar code below. Enable Code 93 (01h) *Disable Code 93 (00h) Set Lengths for Code 93 Parameter # L1 = 1Ah, L2 = 1Bh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 93 to any length, one or two discrete lengths, or lengths within a specific range. • One Discrete Length - Select this option to decode only Code 93 symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 93 symbols with 14 characters, scan Code 93 - One Discrete Length, then scan 1 followed by 4. To correct an error or to change the selection, scan Cancel on page D-2. • Two Discrete Lengths - Select this option to decode only Code 93 symbols containing either of two selected lengths. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 93 symbols containing either 2 or 14 characters, select Code 93 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or to change the selection, scan Cancel on page D-2. • Length Within Range - Select this option to decode a Code 93 symbol with a specific length range. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode Code 93 symbols containing between 4 and 12 characters, first scan Code 93 - Length Within Range. Then scan 0, 4, 1, and 2 (enter a leading zero for single digit numbers). To correct an error or change the selection, scan Cancel on page D-2. • Any Length - Scan this option to decode Code 93 symbols containing any number of characters within the digital scanner’s capability. 14 - 36 Symbol DS6878 Product Reference Guide Set Lengths for Code 93 (continued) Code 93 - One Discrete Length Code 93 - Two Discrete Lengths Code 93 - Length Within Range Code 93 - Any Length Symbologies 14 - 37 Code 11 Code 11 Parameter # 0Ah To enable or disable Code 11, scan the appropriate bar code below. Enable Code 11 (01h) *Disable Code 11 (00h) Set Lengths for Code 11 Parameter # L1 = 1Ch, L2 = 1Dh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 11 to any length, one or two discrete lengths, or lengths within a specific range. • One Discrete Length - Select this option to decode only Code 11 symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 11 symbols with 14 characters, scan Code 11 - One Discrete Length, then scan 1 followed by 4. To correct an error or to change the selection, scan Cancel on page D-2. • Two Discrete Lengths - Select this option to decode only Code 11 symbols containing either of two selected lengths. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 11 symbols containing either 2 or 14 characters, select Code 11 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or to change the selection, scan Cancel on page D-2. • Length Within Range - Select this option to decode a Code 11 symbol with a specific length range. Select lengths using numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode Code 11 symbols containing between 4 and 12 characters, first scan Code 11 - Length Within Range. Then scan 0, 4, 1, and 2 (enter a leading zero for single digit numbers). To correct an error or change the selection, scan Cancel on page D-2. • Any Length - Scan this option to decode Code 11 symbols containing any number of characters within the digital scanner’s capability. 14 - 38 Symbol DS6878 Product Reference Guide Set Lengths for Code 11 (continued) Code 11 - One Discrete Length Code 11 - Two Discrete Lengths Code 11 - Length Within Range Code 11 - Any Length Symbologies 14 - 39 Code 11 Check Digit Verification Parameter # 34h This feature allows the digital scanner to check the integrity of all Code 11 symbols to verify that the data complies with the specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 bar code. The options are to check for one check digit, check for two check digits, or disable the feature. To enable this feature, scan the bar code below corresponding to the number of check digits encoded in the Code 11 symbols. *Disable (00h) One Check Digit (01h) Two Check Digits (02h) 14 - 40 Symbol DS6878 Product Reference Guide Transmit Code 11 Check Digits Parameter # 2Fh This feature selects whether or not to transmit the Code 11 check digit(s). Transmit Code 11 Check Digit(s) (Enable) (01h) *Do Not Transmit Code 11 Check Digit(s) (Disable) (00h) NOTE Code 11 Check Digit Verification must be enabled for this parameter to function. Interleaved 2 of 5 (ITF) Enable/Disable Interleaved 2 of 5 Parameter # 06h To enable or disable Interleaved 2 of 5, scan the appropriate bar code below, and select an Interleaved 2 of 5 length from the following pages. Enable Interleaved 2 of 5 (01h) *Disable Interleaved 2 of 5 (00h) Symbologies 14 - 41 Set Lengths for Interleaved 2 of 5 Parameter # L1 = 16h, L2 = 17h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for I 2 of 5 to any length, one or two discrete lengths, or lengths within a specific range. The range for Interleaved 2 of 5 lengths is 0 - 55. • One Discrete Length - Select this option to decode only I 2 of 5 symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only I 2 of 5 symbols with 14 characters, scan I 2 of 5 - One Discrete Length, then scan 1 followed by 4. To correct an error or to change the selection, scan Cancel on page D-2. • Two Discrete Lengths - Select this option to decode only I 2 of 5 symbols containing either of two selected lengths. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only I 2 of 5 symbols containing either 2 or 14 characters, select I 2 of 5 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or to change the selection, scan Cancel on page D-2. • Length Within Range - Select this option to decode an I 2 of 5 symbol with a specific length range. Select lengths using numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode I 2 of 5 symbols containing between 4 and 12 characters, first scan I 2 of 5 - Length Within Range. Then scan 0, 4, 1, and 2 (enter a leading zero for single digit numbers). To correct an error or change the selection, scan Cancel on page D-2. • Any Length - Scan this option to decode I 2 of 5 symbols containing any number of characters within the digital scanner’s capability. NOTE Due to the construction of the I 2 of 5 symbology, it is possible for a scan line covering only a portion of the code to transmit as a complete scan, yielding less data than is encoded in the bar code. To prevent this, select specific lengths (I 2 of 5 - One Discrete Length, Two Discrete Lengths) for I 2 of 5 applications. 14 - 42 Symbol DS6878 Product Reference Guide Set Lengths for Interleaved 2 of 5 (continued) I 2 of 5 - One Discrete Length I 2 of 5 - Two Discrete Lengths I 2 of 5 - Length Within Range I 2 of 5 - Any Length Symbologies 14 - 43 I 2 of 5 Check Digit Verification Parameter # 31h Enable this feature to check the integrity of all I 2 of 5 symbols to verify the data complies with either the specified Uniform Symbology Specification (USS), or the Optical Product Code Council (OPCC) check digit algorithm. *Disable (00h) USS Check Digit (01h) OPCC Check Digit (02h) Transmit I 2 of 5 Check Digit Parameter # 2Ch Scan the appropriate bar code below to transmit I 2 of 5 data with or without the check digit. Transmit I 2 of 5 Check Digit (Enable) (01h) *Do Not Transmit I 2 of 5 Check Digit (Disable) (00h) 14 - 44 Symbol DS6878 Product Reference Guide Convert I 2 of 5 to EAN-13 Parameter # 52h Enable this parameter to convert 14-character I 2 of 5 codes to EAN-13, and transmit to the host as EAN-13. To accomplish this, the I 2 of 5 code must be enabled, and the code must have a leading zero and a valid EAN-13 check digit. Convert I 2 of 5 to EAN-13 (Enable) (01h) *Do Not Convert I 2 of 5 to EAN-13 (Disable) (00h) Discrete 2 of 5 (DTF) Enable/Disable Discrete 2 of 5 Parameter # 05h To enable or disable Discrete 2 of 5, scan the appropriate bar code below. Enable Discrete 2 of 5 (01h) *Disable Discrete 2 of 5 (00h) Symbologies 14 - 45 Set Lengths for Discrete 2 of 5 Parameter # L1 = 14h, L2 = 15h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for D 2 of 5 to any length, one or two discrete lengths, or lengths within a specific range. The range for Discrete 2 of 5 lengths is 0 - 55. • One Discrete Length - Select this option to decode only D 2 of 5 symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only D 2 of 5 symbols with 14 characters, scan D 2 of 5 - One Discrete Length, then scan 1 followed by 4. To correct an error or to change the selection, scan Cancel on page D-2. • Two Discrete Lengths - Select this option to decode only D 2 of 5 symbols containing either of two selected lengths. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only D 2 of 5 symbols containing either 2 or 14 characters, select D 2 of 5 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or to change the selection, scan Cancel on page D-2. • Length Within Range - Select this option to decode a D 2 of 5 symbol with a specific length range. Select lengths using numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode D 2 of 5 symbols containing between 4 and 12 characters, first scan D 2 of 5 - Length Within Range. Then scan 0, 4, 1, and 2 (enter a leading zero for single digit numbers). To correct an error or change the selection, scan Cancel on page D-2. • Any Length - Scan this option to decode D 2 of 5 symbols containing any number of characters within the digital scanner’s capability. NOTE Due to the construction of the D 2 of 5 symbology, it is possible for a scan line covering only a portion of the code to transmit as a complete scan, yielding less data than is encoded in the bar code. To prevent this, select specific lengths (D 2 of 5 - One Discrete Length, Two Discrete Lengths) for D 2 of 5 applications. 14 - 46 Symbol DS6878 Product Reference Guide Set Lengths for Discrete 2 of 5 (continued) D 2 of 5 - One Discrete Length D 2 of 5 - Two Discrete Lengths D 2 of 5 - Length Within Range D 2 of 5 - Any Length Symbologies 14 - 47 Codabar (NW - 7) Enable/Disable Codabar Parameter # 07h To enable or disable Codabar, scan the appropriate bar code below. Enable Codabar (01h) *Disable Codabar (00h) Set Lengths for Codabar Parameter # L1 = 18h, L2 = 19h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Codabar to any length, one or two discrete lengths, or lengths within a specific range. • One Discrete Length - Select this option to decode only Codabar symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Codabar symbols with 14 characters, scan Codabar - One Discrete Length, then scan 1 followed by 4. To correct an error or to change the selection, scan Cancel on page D-2. • Two Discrete Lengths - Select this option to decode only Codabar symbols containing either of two selected lengths. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Codabar symbols containing either 2 or 14 characters, select Codabar - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or to change the selection, scan Cancel on page D-2. • Length Within Range - Select this option to decode a Codabar symbol with a specific length range. Select lengths using numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode Codabar symbols containing between 4 and 12 characters, first scan Codabar - Length Within Range. Then scan 0, 4, 1, and 2 (enter a leading zero for single digit numbers). To correct an error or change the selection, scan Cancel on page D-2. • Any Length - Scan this option to decode Codabar symbols containing any number of characters within the digital scanner’s capability. 14 - 48 Symbol DS6878 Product Reference Guide Set Lengths for Codabar (continued) Codabar - One Discrete Length Codabar - Two Discrete Lengths Codabar - Length Within Range Codabar - Any Length Symbologies 14 - 49 CLSI Editing Parameter # 36h Enable this parameter to strip the start and stop characters and insert a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Enable this feature if the host system requires this data format. Symbol length does not include start and stop characters. NOTE Enable CLSI Editing (01h) *Disable CLSI Editing (00h) NOTIS Editing Parameter # 37h Enable this parameter to strip the start and stop characters from a decoded Codabar symbol. Enable this feature if the host system requires this data format. Enable NOTIS Editing (01h) *Disable NOTIS Editing (00h) 14 - 50 Symbol DS6878 Product Reference Guide MSI Enable/Disable MSI Parameter # 0Bh To enable or disable MSI, scan the appropriate bar code below. Enable MSI (01h) *Disable MSI (00h) Set Lengths for MSI Parameter # L1 = 1Eh, L2 = 1Fh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for MSI to any length, one or two discrete lengths, or lengths within a specific range. • One Discrete Length - Select this option to decode only MSI symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only MSI symbols with 14 characters, scan MSI - One Discrete Length, then scan 1 followed by 4. To correct an error or to change the selection, scan Cancel on page D-2. • Two Discrete Lengths - Select this option to decode only MSI symbols containing either of two selected lengths. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only MSI symbols containing either 2 or 14 characters, select MSI - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or to change the selection, scan Cancel on page D-2. • Length Within Range - Select this option to decode a MSI symbol with a specific length range. Select lengths using numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode MSI symbols containing between 4 and 12 characters, first scan MSI - Length Within Range. Then scan 0, 4, 1, and 2 (enter a leading zero for single digit numbers). To correct an error or change the selection, scan Cancel on page D-2. • Any Length - Scan this option to decode MSI symbols containing any number of characters within the digital scanner’s capability. Symbologies 14 - 51 Set Lengths for MSI (continued) NOTE Due to the construction of the MSI symbology, it is possible for a scan line covering only a portion of the code to transmit as a complete scan, yielding less data than is encoded in the bar code. To prevent this, select specific lengths (MSI - One Discrete Length, Two Discrete Lengths) for MSI applications. MSI - One Discrete Length MSI - Two Discrete Lengths MSI - Length Within Range MSI - Any Length 14 - 52 Symbol DS6878 Product Reference Guide MSI Check Digits Parameter # 32h With MSI symbols, one check digit is mandatory and always verified by the reader. The second check digit is optional. If the MSI codes include two check digits, scan the Two MSI Check Digits bar code to enable verification of the second check digit. See MSI Check Digit Algorithm on page 14-53 for the selection of second digit algorithms. *One MSI Check Digit (00h) Two MSI Check Digits (01h) Transmit MSI Check Digit(s) Parameter # 2Eh Scan a bar code below to transmit MSI data with or without the check digit. Transmit MSI Check Digit(s) (Enable) (01h *Do Not Transmit MSI Check Digit(s) (Disable) (00h) Symbologies 14 - 53 MSI Check Digit Algorithm Parameter # 33h Two algorithms are possible for the verification of the second MSI check digit. Select the bar code below corresponding to the algorithm used to encode the check digit. MOD 10/MOD 11 (00h) *MOD 10/MOD 10 (01h) Chinese 2 of 5 Enable/Disable Chinese 2 of 5 Parameter # F0h 98h To enable or disable Chinese 2 of 5, scan the appropriate bar code below. Enable Chinese 2 of 5 (01h) *Disable Chinese 2 of 5 (00h) 14 - 54 Symbol DS6878 Product Reference Guide Matrix 2 of 5 Enable/Disable Matrix 2 of 5 Parameter # F1h 6Ah To enable or disable Matrix 2 of 5, scan the appropriate bar code below. Enable Matrix 2 of 5 (01h) *Disable Matrix 2 of 5 (00h) Symbologies 14 - 55 Set Lengths for Matrix 2 of 5 Parameter # L1 = F1h 6Bh, L2 = F1h 6Ch The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Matrix 2 of 5 to any length, one or two discrete lengths, or lengths within a specific range. • One Discrete Length - Select this option to decode only Matrix 2 of 5 symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Matrix 2 of 5 symbols with 14 characters, scan Matrix 2 of 5 - One Discrete Length, then scan 1 followed by 4. To correct an error or to change the selection, scan Cancel on page D-2. • Two Discrete Lengths - Select this option to decode only Matrix 2 of 5 symbols containing either of two selected lengths. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Matrix 2 of 5 symbols containing either 2 or 14 characters, select Matrix 2 of 5 Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or to change the selection, scan Cancel on page D-2. • Length Within Range - Select this option to decode a Matrix 2 of 5 symbol with a specific length range. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode Matrix 2 of 5 symbols containing between 4 and 12 characters, first scan Matrix 2 of 5 - Length Within Range. Then scan 0, 4, 1, and 2 (enter a leading zero for single digit numbers). To correct an error or change the selection, scan Cancel on page D-2. • Any Length - Scan this option to decode Matrix 2 of 5 symbols containing any number of characters within the digital scanner’s capability. *Matrix 2 of 5 - One Discrete Length Matrix 2 of 5 - Two Discrete Lengths Matrix 2 of 5 - Length Within Range Matrix 2 of 5 - Any Length 14 - 56 Symbol DS6878 Product Reference Guide Matrix 2 of 5 Redundancy Parameter # F1h 6Dh To enable or disable Matrix 2 of 5 redundancy, scan the appropriate bar code below. Enable Matrix 2 of 5 Redundancy (01h) *Disable Matrix 2 of 5 Redundancy (00h) Matrix 2 of 5 Check Digit Parameter # F1h 6Eh The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the Matrix 2 of 5 check digit. Enable Matrix 2 of 5 Check Digit (01h) *Disable Matrix 2 of 5 Check Digit (00h) Symbologies 14 - 57 Transmit Matrix 2 of 5 Check Digit Parameter # F1h 6Fh Scan a bar code below to transmit Matrix 2 of 5 data with or without the check digit. Transmit Matrix 2 of 5 Check Digit (01h) *Do Not Transmit Matrix 2 of 5 Check Digit (00h) Korean 3 of 5 Enable/Disable Korean 3 of 5 Parameter # F1h 45h To enable or disable Korean 3 of 5, scan the appropriate bar code below. NOTE The length for Korean 3 of 5 is fixed at 6. Enable Korean 3 of 5 (01h) *Disable Korean 3 of 5 (00h) 14 - 58 Symbol DS6878 Product Reference Guide Inverse 1D Parameter # F1h 4Ah This parameter sets the 1D inverse decoder setting. Options are: • Regular Only - the digital scanner decodes regular 1D bar codes only. • Inverse Only - the digital scanner decodes inverse 1D bar codes only. • Inverse Autodetect - the digital scanner decodes both regular and inverse 1D bar codes. *Regular (00h) Inverse Only (01h) Inverse Autodetect (02h) Symbologies 14 - 59 Postal Codes US Postnet Parameter # 59h To enable or disable US Postnet, scan the appropriate bar code below. Enable US Postnet (01h) *Disable US Postnet (00h) US Planet Parameter # 5Ah To enable or disable US Planet, scan the appropriate bar code below. Enable US Planet (01h) *Disable US Planet (00h) 14 - 60 Symbol DS6878 Product Reference Guide Transmit US Postal Check Digit Parameter # 5Fh Select whether to transmit US Postal data, which includes both US Postnet and US Planet, with or without the check digit. *Transmit US Postal Check Digit (01h) Do Not Transmit US Postal Check Digit (00h) UK Postal Parameter # 5Bh To enable or disable UK Postal, scan the appropriate bar code below. Enable UK Postal (01h) *Disable UK Postal (00h) Symbologies 14 - 61 Transmit UK Postal Check Digit Parameter # 60h Select whether to transmit UK Postal data with or without the check digit. *Transmit UK Postal Check Digit (01h) Do Not Transmit UK Postal Check Digit (00h) Japan Postal Parameter # F0h, 22h To enable or disable Japan Postal, scan the appropriate bar code below. Enable Japan Postal (01h) *Disable Japan Postal (00h) 14 - 62 Symbol DS6878 Product Reference Guide Australian Postal Parameter # F0h, 23h To enable or disable Australian Postal, scan the appropriate bar code below. Enable Australian Postal (01h) *Disable Australian Postal (00h) Netherlands KIX Code Parameter # F0h, 46h To enable or disable Netherlands KIX Code, scan the appropriate bar code below. Enable Netherlands KIX Code (01h) *Disable Netherlands KIX Code (00h) Symbologies 14 - 63 USPS 4CB/One Code/Intelligent Mail Parameter # F1h 50h To enable or disable USPS 4CB/One Code/Intelligent Mail, scan the appropriate bar code below. Enable USPS 4CB/One Code/Intelligent Mail (01h) *Disable USPS 4CB/One Code/Intelligent Mail (00h) UPU FICS Postal Parameter # F1h 63h To enable or disable UPU FICS Postal, scan the appropriate bar code below. Enable UPU FICS Postal (01h) *Disable UPU FICS Postal (00h) 14 - 64 Symbol DS6878 Product Reference Guide GS1 DataBar The variants of GS1 DataBar are DataBar-14, DataBar Expanded, and DataBar Limited. The limited and expanded versions have stacked variants. Scan the appropriate bar codes to enable or disable each variant of GS1 DataBar. GS1 DataBar-14 Parameter # F0h 52h. Enable GS1 DataBar-14 (01h) *Disable GS1 DataBar 14 (00h) GS1 DataBar Limited Parameter # F0h 53h. Enable GS1 DataBar Limited (01h) *Disable GS1 DataBar Limited (00h) Symbologies 14 - 65 GS1 DataBar Expanded Parameter # F0h 54h. Enable GS1 DataBar Expanded (01h) *Disable GS1 DataBar Expanded (00h) Convert GS1 DataBar to UPC/EAN Parameter # F0h, 8Dh This parameter only applies to GS1 DataBar-14 and GS1 DataBar Limited symbols not decoded as part of a Composite symbol. Enable this to strip the leading '010' from DataBar-14 and DataBar Limited symbols encoding a single zero as the first digit, and report the bar code as EAN-13. For bar codes beginning with two or more zeros but not six zeros, this parameter strips the leading '0100' and reports the bar code as UPC-A. The UPC-A Preamble parameter that transmits the system character and country code applies to converted bar codes. Note that neither the system character nor the check digit can be stripped. Enable Convert GS1 DataBar to UPC/EAN (01h) *Disable Convert GS1 DataBar to UPC/EAN (00h) 14 - 66 Symbol DS6878 Product Reference Guide Composite Composite CC-C Parameter # F0h 55h Scan a bar code below to enable or disable Composite bar codes of type CC-C. Enable CC-C (01h) *Disable CC-C (00h) Composite CC-A/B Parameter # F0h 56h Scan a bar code below to enable or disable Composite bar codes of type CC-A/B. Enable CC-A/B (01h) *Disable CC-A/B (00h) Symbologies 14 - 67 Composite TLC-39 Parameter # F0h 73h Scan a bar code below to enable or disable Composite bar codes of type TLC-39. Enable TLC39 (01h) *Disable TLC39 (00h) UPC Composite Mode Parameter # F0h 58h Select an option for linking UPC symbols with a 2D symbol during transmission as if they were one symbol: • Select UPC Never Linked to transmit UPC bar codes regardless of whether a 2D symbol is detected. • Select UPC Always Linked to transmit UPC bar codes and the 2D portion. If 2D is not present, the UPC bar code does not transmit. • If you select Autodiscriminate UPC Composites, the digital scanner determines if there is a 2D portion, then transmits the UPC, as well as the 2D portion if present. *UPC Never Linked (00h) UPC Always Linked (01h) Autodiscriminate UPC Composites (02h) 14 - 68 Symbol DS6878 Product Reference Guide Composite Beep Mode Parameter # F0h, 8Eh To select the number of decode beeps when a composite bar code is decoded, scan the appropriate bar code. Single Beep after both are decoded (00h) *Beep as each code type is decoded (01h) Double Beep after both are decoded (02h) GS1-128 Emulation Mode for UCC/EAN Composite Codes Parameter # F0h, ABh Select whether to enable or disable this mode. Enable GS1-128 Emulation Mode for UCC/EAN Composite Codes (01h) *Disable GS1-128 Emulation Mode for UCC/EAN Composite Codes (00h) Symbologies 14 - 69 2D Symbologies Enable/Disable PDF417 Parameter # 0Fh To enable or disable PDF417, scan the appropriate bar code below. *Enable PDF417 (01h) Disable PDF417 (00h) Enable/Disable MicroPDF417 Parameter # E3h To enable or disable MicroPDF417, scan the appropriate bar code below. Enable MicroPDF417 (01h) *Disable MicroPDF417 (00h) 14 - 70 Symbol DS6878 Product Reference Guide Code 128 Emulation Parameter # 7Bh Enable this parameter to transmit data from certain MicroPDF417 symbols as Code 128. AIM Code ID Character (01h) on page 4-34 must be enabled for this parameter to work. Enable Code 128 Emulation to transmit these MicroPDF417 symbols with one of the following prefixes: ]C1 if the first codeword is 903-905 ]C2 if the first codeword is 908 or 909 ]C0 if the first codeword is 910 or 911 Disable Code 128 Emulation to transmit these MicroPDF417 symbols with one of the following prefixes: ]L3 if the first codeword is 903-905 ]L4 if the first codeword is 908 or 909 ]L5 if the first codeword is 910 or 911 Scan a bar code below to enable or disable Code 128 Emulation. NOTE Linked MicroPDF codewords 906, 907, 912, 914, and 915 are not supported. Use GS1 Composites instead. Enable Code 128 Emulation (01h) *Disable Code 128 Emulation (00h) Symbologies 14 - 71 Data Matrix Parameter # F0h, 24h To enable or disable Data Matrix, scan the appropriate bar code below. *Enable Data Matrix (01h) Disable Data Matrix (00h) Data Matrix Inverse Parameter # F1h 4Ch This parameter sets the Data Matrix inverse decoder setting. Options are: • Regular Only - the digital scanner decodes regular Data Matrix bar codes only. • Inverse Only - the digital scanner decodes inverse Data Matrix bar codes only. • Inverse Autodetect - the digital scanner decodes both regular and inverse Data Matrix bar codes. *Regular (00h) Inverse Only (01h) Inverse Autodetect (02h) 14 - 72 Symbol DS6878 Product Reference Guide Maxicode Parameter # F0h, 26h To enable or disable Maxicode, scan the appropriate bar code below. Enable Maxicode (01h) *Disable Maxicode (00h) QR Code Parameter # F0h,25h To enable or disable QR Code, scan the appropriate bar code below. *Enable QR Code (01h) Disable QR Code (00h) Symbologies 14 - 73 QR Inverse Parameter # F1h 4Bh This parameter sets the QR inverse decoder setting. Options are: • Regular Only - the digital scanner decodes regular QR bar codes only. • Inverse Only - the digital scanner decodes inverse QR bar codes only. • Inverse Autodetect - the digital scanner decodes both regular and inverse QR bar codes. *Regular (00h) Inverse Only (01h) Inverse Autodetect (02h) MicroQR Parameter # F1h 3Dh To enable or disable MicroQR, scan the appropriate bar code below. *Enable MicroQR (01h) Disable MicroQR (00h) 14 - 74 Symbol DS6878 Product Reference Guide Aztec Parameter # F1h 3Eh To enable or disable Aztec, scan the appropriate bar code below. *Enable Aztec (01h) Disable Aztec (00h) Aztec Inverse Parameter # F1h 4Dh This parameter sets the Aztec inverse decoder setting. Options are: • Regular Only - the digital scanner decodes regular Aztec bar codes only. • Inverse Only - the digital scanner decodes inverse Aztec bar codes only. • Inverse Autodetect - the digital scanner decodes both regular and inverse Aztec bar codes. *Regular (00h) Inverse Only (01h) Inverse Autodetect (02h) Symbologies 14 - 75 Redundancy Level Parameter # 4Eh The digital scanner offers four levels of decode redundancy. Select higher redundancy levels for decreasing levels of bar code quality. As redundancy levels increase, the digital scanner’s aggressiveness decreases. Select the redundancy level appropriate for the bar code quality. Redundancy Level 1 The following code types must be successfully read twice before being decoded: Table 14-2 Redundancy Level 1 Codes Code Type Code Length Codabar 8 characters or less MSI 4 characters or less D 2 of 5 8 characters or less I 2 of 5 8 characters or less Redundancy Level 2 The following code types must be successfully read twice before being decoded: Table 14-3 Redundancy Level 2 Codes Code Type All Code Length All Redundancy Level 3 Code types other than the following must be successfully read twice before being decoded. The following codes must be read three times: Table 14-4 Redundancy Level 3 Codes Code Type Code Length MSI 4 characters or less D 2 of 5 8 characters or less I 2 of 5 8 characters or less Codabar 8 characters or less 14 - 76 Symbol DS6878 Product Reference Guide Redundancy Level 4 The following code types must be successfully read three times before being decoded: Table 14-5 Redundancy Level 4 Codes Code Type Code Length All All *Redundancy Level 1 (01h) Redundancy Level 2 (02h) Redundancy Level 3 (03h) Redundancy Level 4 (04h) Symbologies 14 - 77 Security Level Parameter # 4Dh The digital scanner offers four levels of decode security for delta bar codes, which include the Code 128 family, UPC/EAN, and Code 93. Select increasing levels of security for decreasing levels of bar code quality. There is an inverse relationship between security and digital scanner aggressiveness, so choose only that level of security necessary for any given application. • Security Level 0: This setting allows the digital scanner to operate in its most aggressive state, while providing sufficient security in decoding most “in-spec” bar codes. • Security Level 1: This default setting eliminates most misdecodes. • Security Level 2: Select this option if Security level 1 fails to eliminate misdecodes. • Security Level 3: If you selected Security Level 2 and misdecodes still occur, select this security level. Be advised, selecting this option is an extreme measure against mis-decoding severely out of spec bar codes. Selecting this level of security significantly impairs the decoding ability of the digital scanner. If you need this level of security, try to improve the quality of the bar codes. *Security Level 0 (00h) Security Level 1 (01h) Security Level 2 (02h) Security Level 3 (03h) 14 - 78 Symbol DS6878 Product Reference Guide Intercharacter Gap Size Parameter # F0h, 7Dh The Code 39 and Codabar symbologies have an intercharacter gap that is typically quite small. Due to various bar code-printing technologies, this gap can grow larger than the maximum size allowed, preventing the digital scanner from decoding the symbol. If this problem occurs, scan the Large Intercharacter Gaps parameter to tolerate these out-of-specification bar codes. *Normal Intercharacter Gaps (06h) Large Intercharacter Gaps (0Ah) Report Version Scan the bar code below to report the version of software installed in the digital scanner. Report Software Version Symbologies 14 - 79 Macro PDF Features Macro PDF is a special feature for concatenating multiple PDF symbols into one file. The scanner can decode symbols that are encoded with this feature, and can store more than 64 Kb of decoded data stored in up to 50 MacroPDF symbols. CAUTION When printing, keep each Macro PDF sequence separate, as each sequence has unique identifiers. Do not mix bar codes from several Macro PDF sequences, even if they encode the same data. When scanning Macro PDF sequences, scan the entire Macro PDF sequence without interruption. If, when scanning a mixed sequence, the digital scanner emits two long low beeps (Low/Low) this indicates an inconsistent file ID or inconsistent symbology error. Flush Macro Buffer This flushes the buffer of all decoded Macro PDF data stored to that point, transmits it to the host device, and aborts from Macro PDF mode. Flush Macro PDF Buffer Abort Macro PDF Entry This clears all currently-stored Macro PDF data in the buffer without transmission and aborts from Macro PDF mode. Abort Macro PDF Entry 14 - 80 Symbol DS6878 Product Reference Guide Chapter 15 Advanced Data Formatting Introduction Advanced Data Formatting (ADF) is a means of customizing data before transmission to the host device. Scan data can be edited to suit particular requirements. To implement ADF, scan a related series of bar codes, which begin on page 15-8, which allows programming the digital scanner with Advanced Data Formatting (ADF) Rules. Avoid using ADF formatting with bar codes containing more than 60 characters. To add a prefix or suffix value for such bar codes, use Prefix/Suffix Values on page 5-34. Using ADF with longer bar codes transmits the bar code in segments of length 252 or less (depending on the host selected), and applies the rule to each segment Rules: Criteria Linked to Actions ADF uses rules to customize data. These rules perform detailed actions when the data meets certain criteria. One rule may consist of single or multiple criteria applied to single or multiple actions. For instance, a data formatting rule could be: Criteria: When scan data is Code 39, length 12, and data at the start position is the string “129”, Actions: pad all sends with zeros to length 8, send all data up to X, send a space. Scanning a Code 39 bar code of 1299X1559828 transmits the following: 00001299 . If you scan a Code 39 bar code of 1299X15598, this rule is ignored because the bar code did not meet the length criteria. The rule specifies the editing conditions and requirements before data transmission occurs. 15 - 2 Symbol DS6878 Product Reference Guide Using ADF Bar Codes When programming a rule, make sure the rule is logically correct. Plan ahead before scanning. To program each data formatting rule: • Start the Rule. Scan the Begin New Rule bar code on page 15-8. • Specify Criteria. Scan the bar codes for all pertinent criteria. Criteria can include code type (e.g., Code 128), code length, or data that contains a specific character string (e.g., the digits “129”). See Criteria on page 15-11. • Select Actions. Scan all actions related to, or affecting, these criteria. The actions of a rule specify how to format the data for transmission. See Actions on page 15-24. • Save the Rule. Scan the Save Rule bar code on page 15-8. This places the rule in the “top” position in the rule buffer. • To correct any errors, see Erase on page 15-9 to erase criteria, actions, and entire rules. ADF Bar Code Menu Example This section provides an example of how to enter and use ADF rules for scan data. An auto parts distribution center wants to encode manufacturer ID, part number, and destination code into their own Code 128 bar codes. The distribution center also has products that carry UPC bar codes, placed there by the manufacturer. The Code 128 bar codes have the following format: MMMMMPPPPPDD Where: M = Manufacturer ID P = Part Number D = Destination Code The distribution center uses a PC with dedicated control characters for manufacturer ID , part number , and destination code . At this center the UPC data is treated as manufacturer ID code. The following rules need to be entered: When scanning data of code type Code 128, send the next 5 characters, send the manufacturer ID key , send the next 5 characters, send the part number key , send the next 2 characters, send the destination code key . When scanning data of code type UPC/EAN, send all data, send the manufacturer ID key . To enter these rules, see the following steps. Advanced Data Formatting 15 - 3 Rule 1: The Code 128 Scanning Rule Step Bar Code On Page Beep Indication Begin New Rule 15-8 High High Code 128 15-11 High High Send next 5 characters 15-25 High High Send 15-45 High High Send next 5 characters 15-25 High High Send 15-45 High High Send next 2 characters 15-24 High High Send 15-44 High High Save Rule 15-8 High Low High Low Rule 2: The UPC Scanning Rule Step Bar Code On Page Beep Indication Begin New Rule 15-8 High High UPC/EAN 15-13 High High Send all remaining data 15-24 High High Send 15-45 High High Save Rule 15-8 High Low High Low To correct any errors made while entering this rule, scan the Quit Entering Rules bar code on page 15-9. If you already saved the rule, scan the Erase Previously Saved Rule bar code on page 15-9. Alternate Rule Sets You can group ADF rules into one of four alternate sets which you can turn on and off when needed. This is useful to format the same message in different ways. For example, a Code 128 bar code contains the following information: Class (2 digits), Stock Number (8) digits, Price (5 digits) The bar code might look like this: 245671243701500 where: Class = 24 Stock Number = 56712437 Price = 01500 Ordinarily, data is sent as follows: 24 (class key) 56712437 (stock key) 01500 (enter key) But, when there is a sale, send only the following: 24 (class key) 56712437 (stock key) 15 - 4 Symbol DS6878 Product Reference Guide and the cashier keys the price manually. To implement this, first enter an ADF rule that applies to the normal situation, such as: Scan Rule Belongs to Set 1. When scanning a bar code of length 15, send the next 2 characters, send the class key, send the next 8 characters, send the stock key, send the data that remains, send the Enter key. The “sale” rule may look like this: Scan Rule Belongs to Set 2. When scanning a bar code of length 15, send the next 2 characters, send the class key, send the next 8 characters, send the stock key. To switch between the two sets of rules, program a “switching rule” that specifies what type of bar code to scan to switch between the rule sets. For example, in the case of the “sale” rule above, the rule programmer wants the cashier to scan the bar code “M” before a sale. To do this, a rule can be entered as follows: When scanning a bar code of length 1 that begins with “M”, select rule set number 1. Program another rule to switch back. When scanning a bar code of length 1 that begins with “N”, turn off rule set number 1. Or include the switching back to normal rules in the “sale” rule: When scanning a bar code of length 15, send the next 2 characters, send the class key, send the next 8 characters, send the stock key, turn off rule set 1. For optimal results, scan the Disable All Rule Sets bar code on page 15-10 after programming a rule belonging to an alternate rule set. In addition to enabling and disabling rule sets within the rules, enable or disable them by scanning the appropriate bar codes on page 15-10. Rules Hierarchy (in Bar Codes) The order of programming individual rules is important.Program the most general rule first. All programmed rules are stored in a buffer. As they are programmed, they are stored at the “top” of a rules list. If you create three rules, the list is configured as follows: Third Rule Second Rule First Rule When you scan data, the rules list is checked from top to bottom to determine if the criteria matches (and therefore, if the actions occur). Input is modified into the data format specified by the first matching set of criteria it finds. Be sure to program the most general rule first. For example, if the THIRD rule states: When scanning a bar code of any length, send all data, then send the ENTER key. And the SECOND rule states: When scanning a Code 128 bar code of length 12, send the first four characters, then send the ENTER key, then send all remaining data. and you scan a Code 128 bar code of length 12, the THIRD rule applies, and the SECOND rule appears to not function. Advanced Data Formatting 15 - 5 Note that using the standard data editing functions also creates ADF rules. Scan options are entered as ADF rules, and the hierarchy mentioned above also applies to them. For the digital scanner, this applies to prefix/suffix programming in the parameter Scan Data Transmission Format on page 5-35. These rules reside in the same “rule list” as ADF Rules, so the order you create them is also important. Default Rules Every unit has a default rule to send all scan data. Units with custom software may have one or more default rules burned in. The rules hierarchy checks user programmable rules first, then the default rules. Disable default rules by entering the following general rule in the user programmable buffer: When receiving scan data, send all data. Since this rule always applies, ADF never applies the default rules. 15 - 6 Symbol DS6878 Product Reference Guide ADF Bar Codes Table 15-1 lists the bar codes available through ADF. Table 15-1 ADF Bar Codes Parameter Page Number Special Commands 15-8 Pause Duration 15-8 Begin New Rule 15-8 Save Rule 15-8 Erase 15-9 Quit Entering Rules 15-9 Disable Rule Set 15-10 Criteria 15-11 Code Types 15-11 Code Lengths 15-15 1 Character - 6 Characters 15-15 7 Characters - 13 Characters 15-16 14 Characters - 20 Characters 15-17 21 Characters - 27 Characters 15-18 28 Characters - 30 Characters 15-19 Specific String at Start 15-19 Specific String, Any Location 15-20 Any Message OK 15-20 Numeric Keypad 15-21 Rule Belongs To Set 15-23 Actions Send Data 15-24 15-24 Send Data Up To Character 15-24 Send Next Character 15-24 Send All Data That Remains 15-24 Send Next 2 Characters - Send Next 20 Characters 15-24 Move Cursor 15-28 Advanced Data Formatting 15 - 7 Table 15-1 ADF Bar Codes (Continued) Parameter Page Number Send Pause 15-28 Skip Ahead 15-29 Skip Back 15-30 Send Preset Value 15-32 Remove All Spaces 15-32 Crunch All Spaces 15-32 Stop Space Removal 15-32 Remove Leading Zeros 15-33 Stop Zero Removal 15-33 Pad Data with Spaces 15-34 Pad Data with Zeros 15-38 Beeps 15-43 Control Characters 15-43 Keyboard Characters 15-48 Send ALT Characters 15-61 Send Keypad Characters 15-67 Send Function Key 15-72 Send F1 Key - Send F24 Key 15-72 Send PF1 Key - Send PF30 Key 15-75 Send Right Control Key 15-79 Send Graphic User Interface (GUI) Characters 15-80 Send GUI 0 - Send GUI 9 15-80 Send GUI A - Send GUI Z 15-81 Turn On/Off Rule Sets 15-85 Alphanumeric Keyboard 15-87 Space - ` 15-87 0-9 15-91 A-Z 15-92 Cancel 15-96 15 - 8 Symbol DS6878 Product Reference Guide Table 15-1 ADF Bar Codes (Continued) Page Number Parameter End of Message 15-96 a-z 15-96 {-~ 15-100 Special Commands Pause Duration Use this parameter, along with Send Pause on page 15-28, to insert a pause in the data transmission. Set the pause by scanning a two-digit number (i.e., two bar codes) from Appendix D, Numeric Bar Codes in 0.1 second intervals. For example, scanning bar codes 0 and 1 inserts a 0.1 second pause; 0 and 5 inserts a 0.5 second delay. To correct an error or change a selection, scan Cancel on page D-3. Pause Duration Begin New Rule Scan the bar code below to start entering a new rule Begin New Rule Save Rule Scan the bar code below to save the rule. Save Rule Advanced Data Formatting 15 - 9 Erase Use these bar codes to erase criteria, actions, or rules. Erase Criteria And Start Again Erase Actions And Start Again Erase Previously Saved Rule Erase All Rules Quit Entering Rules Scan the bar code below to quit entering rules. Quit Entering Rules 15 - 10 Symbol DS6878 Product Reference Guide Disable Rule Set Use these bar codes to disable rule sets. Disable Rule Set 1 Disable Rule Set 2 Disable Rule Set 3 Disable Rule Set 4 Disable All Rule Sets Advanced Data Formatting 15 - 11 Criteria Code Types Scan the bar codes for all code to be affected by the rule. Scan the codes in succession, prior to selecting other criteria. To select all code types, do not scan any code type. Code 39 Codabar GS1 DataBar-14 GS1 DataBar Limited GS1 DataBar Expanded Code 128 D 2 OF 5 15 - 12 Symbol DS6878 Product Reference Guide Code Types (continued) IATA 2 OF 5 I 2 OF 5 Code 93 UPC-A UPC-E EAN-8 EAN-13 Advanced Data Formatting 15 - 13 Code Types (continued) MSI GS1-128 UPC-E1 Bookland EAN Trioptic Code 39 Code 11 Code 32 15 - 14 Symbol DS6878 Product Reference Guide Code Types (continued) ISBT 128 Coupon Code TLC 39 UPC/EAN Composites GS1 DataBar and EAN128 Composites NOTE When selecting composite bar codes, enable AIM IDs if parsing UPC or EAN composite data, or data from an application that uses symbol separators. Advanced Data Formatting 15 - 15 Code Lengths Scan these bar codes to define the number of characters the selected code type must contain. Select one length per rule only. Do not select any code length to select code types of any length. 1 Character 2 Characters 3 Characters 4 Characters 5 Characters 6 Characters 15 - 16 Symbol DS6878 Product Reference Guide Code Lengths (continued) 7 Characters 8 Characters 9 Characters 10 Characters 11 Characters 12 Characters 13 Characters Advanced Data Formatting 15 - 17 Code Lengths (continued) 14 Characters 15 Characters 16 Characters 17 Characters 18 Characters 19 Characters 20 Characters 15 - 18 Symbol DS6878 Product Reference Guide Code Lengths (continued) 21 Characters 22 Characters 23 Characters 24 Characters 25 Characters 26 Characters 27 Characters Advanced Data Formatting 15 - 19 Code Lengths (continued) 28 Characters 29 Characters 30 Characters Message Containing A Specific Data String Use this feature to select whether the formatting affects data that begins with a specific character or data string, or contains a specific character or data string. There are 4 features: • Specific String at Start • Specific String, Any Location • Any Message OK • Rule Belongs to Set Specific String at Start 1. Scan the following bar code. 2. Scan the bar codes representing the desired character or characters (up to a total of 8) using the Alphanumeric Keyboard on page 15-87. 3. Scan End of Message bar code on page 15-96. Specific String At Start 15 - 20 Symbol DS6878 Product Reference Guide Specific String, Any Location 1. Scan the following bar code. 2. Enter a location by scanning a two-digit number representing the position (use a leading “zero” if necessary) using the Numeric Keypad on page 15-21. 3. Scan the bar codes representing the desired character or characters (up to a total of 8) using the Alphanumeric Keyboard on page 15-87. 4. Scan End of Message bar code on page 15-96. Specific String Any Location Any Message OK Do not scan any bar code to format all selected code types, regardless of information contained. Advanced Data Formatting 15 - 21 Numeric Keypad Do not confuse bar codes on this page with those on the alphanumeric keyboard. 15 - 22 Symbol DS6878 Product Reference Guide Numeric Keypad (continued) Cancel Advanced Data Formatting 15 - 23 Rule Belongs To Set Select the set to which a rule belongs. There are four possible rule sets. See Alternate Rule Sets on page 15-3 for more information about rule sets. Rule Belongs To Set 1 Rule Belongs To Set 2 Rule Belongs To Set 3 Rule Belongs To Set 4 15 - 24 Symbol DS6878 Product Reference Guide Actions Select how to format the data for transmission. Send Data Send all data that remains, send all data up to a specific character selected from the Alphanumeric Keyboard on page 15-87, or send the next X characters. Note that only bar codes for Send Next 1 to 20 appear here, and can be scanned multiple times to send values greater then 20. For instance, to send the next 28 characters, scan Send Next 20 Characters, then Send Next 8 Characters. Send Data Up To Character Send All Data That Remains Send Next Character Send Next 2 Characters Send Next 3 Characters Send Next 4 Characters Advanced Data Formatting 15 - 25 Send Data (continued) Send Next 5 Characters Send Next 6 Characters Send Next 7 Characters Send Next 8 Characters Send Next 9 Characters Send Next 10 Characters Send Next 11 Characters 15 - 26 Symbol DS6878 Product Reference Guide Send Data (continued) Send Next 12 Characters Send Next 13 Characters Send Next 14 Characters Send Next 15 Characters Send Next 16 Characters Send Next 17 Characters Send Next 18 Characters Advanced Data Formatting 15 - 27 Send Data (continued) Send Next 19 Characters Send Next 20 Characters Setup Field(s) Table 15-2 Setup Field(s) Definitions Parameter Description Page Move Cursor To a Character Scan the Move Cursor To Character on page 15-28, then any printable ASCII character from the Alphanumeric Keyboard on page 15-87. This moves the cursor to the position after the matching character. If the character is not there, the rule fails and ADF tries the next rule. 15-28 Move Cursor to Start of Data Scan this bar code to move the cursor to the beginning of the data. 15-28 Move Cursor Past a Character This action moves the cursor past all sequential occurrences of a selected character. For example, if the selected character is ‘A’, then the cursor moves past ‘A’, ‘AA’, ‘AAA’, etc. Scan the Move Cursor Past Character on page 15-28, then select a character from the Alphanumeric Keyboard on page 15-87. If the character is not there, the cursor does not move (i.e., has no effect). 15-28 Skip Ahead “N” Characters Scan one of these bar codes to select the number of positions ahead to move the cursor. 15-29 Skip Back “N” Characters Scan one of these bar codes to select the number of positions back to move the cursor. 15-30 Send Preset Value Send Values 1 through 6 by scanning the appropriate bar code. Set these values using the prefix/suffix values in Table 7-4 on page 7-19. Value 1 = Scan Suffix Value 2 = Scan Prefix Values 3-6 are not applicable 15-30 Move Cursor 15 - 28 Symbol DS6878 Product Reference Guide Move Cursor Scan a bar code below to move the cursor in relation to a specified character. Then enter a character by scanning a bar code from the Alphanumeric Keyboard on page 15-87. NOTE If there is no match and the rule fails, the next rule is checked. Move Cursor To Character Move Cursor To Start Move Cursor Past Character Send Pause Scan the bar code below to insert a pause in the transmission of data. See Pause Duration on page 15-8 to set the length of this pause. Send Pause Advanced Data Formatting 15 - 29 Skip Ahead Use the following bar codes to skip ahead characters. Skip Ahead 1 Character Skip Ahead 2 Characters Skip Ahead 3 Characters Skip Ahead 4 Characters Skip Ahead 5 Characters Skip Ahead 6 Characters Skip Ahead 7 Characters 15 - 30 Symbol DS6878 Product Reference Guide Skip Ahead (continued) Skip Ahead 8 Characters Skip Ahead 9 Characters Skip Ahead 10 Characters Skip Back Use the following bar codes to skip back characters. Skip Back 1 Character Skip Back 2 Characters Skip Back 3 Characters Advanced Data Formatting 15 - 31 Skip Back (continued) Skip Back 4 Characters Skip Back 5 Characters Skip Back 6 Characters Skip Back 7 Characters Skip Back 8 Characters Skip Back 9 Characters Skip Back 10 Characters 15 - 32 Symbol DS6878 Product Reference Guide Send Preset Value Use these bar codes to send preset values. See Prefix/Suffix Values on page 5-34 to set these values. Send Prefix Send Suffix Modify Data Modify data as described below. The following actions work for all send commands that follow it within a rule. Programming pad zeros to length 6, send next 3 characters, stop padding, send next 5 characters, adds three zeros to the first send, and the next send is unaffected by the padding. These options do not apply to the Send Keystroke or Send Preset Value options. Remove All Spaces To remove all spaces in the send commands that follow, scan the bar code below. Remove All Spaces Crunch All Spaces To leave one space between words, scan the bar code below. This also removes all leading and trailing spaces. Crunch All Spaces Stop Space Removal Scan the bar code below to disable space removal. Stop Space Removal Advanced Data Formatting 15 - 33 Remove Leading Zeros Scan the bar code below to remove all leading zeros. Remove Leading Zeros Stop Zero Removal Scan the bar code below to disable the removal of zeros. Stop Zero Removal 15 - 34 Symbol DS6878 Product Reference Guide Pad Data with Spaces To pad data to the left, scan the bar code containing the desired number of spaces. Use Send commands to activate this parameter. Pad Spaces To Length 1 Pad Spaces To Length 2 Pad Spaces To Length 3 Pad Spaces To Length 4 Pad Spaces To Length 5 Pad Spaces To Length 6 Pad Spaces To Length 7 Advanced Data Formatting 15 - 35 Pad Data with Spaces (continued) Pad Spaces To Length 8 Pad Spaces To Length 9 Pad Spaces To Length 10 Pad Spaces To Length 11 Pad Spaces To Length 12 Pad Spaces To Length 13 Pad Spaces To Length 14 15 - 36 Symbol DS6878 Product Reference Guide Pad Data with Spaces (continued) Pad Spaces To Length 15 Pad Spaces To Length 16 Pad Spaces To Length 17 Pad Spaces To Length 18 Pad Spaces To Length 19 Pad Spaces To Length 20 Pad Spaces To Length 21 Advanced Data Formatting 15 - 37 Pad Data with Spaces (continued) Pad Spaces To Length 22 Pad Spaces To Length 23 Pad Spaces To Length 24 Pad Spaces To Length 25 Pad Spaces To Length 26 Pad Spaces To Length 27 Pad Spaces To Length 28 15 - 38 Symbol DS6878 Product Reference Guide Pad Data with Spaces (continued) Pad Spaces To Length 29 Pad Spaces To Length 30 Stop Pad Spaces Pad Data with Zeros To pad data to the left, scan the bar code containing the desired number of zeros. Use Send commands to activate this parameter. Pad Zeros To Length 1 Pad Zeros To Length 2 Pad Zeros To Length 3 Advanced Data Formatting 15 - 39 Pad Data with Zeros (continued) Pad Zeros To Length 4 Pad Zeros To Length 5 Pad Zeros To Length 6 Pad Zeros To Length 7 Pad Zeros To Length 8 Pad Zeros To Length 9 Pad Zeros To Length 10 15 - 40 Symbol DS6878 Product Reference Guide Pad Data with Zeros (continued) Pad Zeros To Length 11 Pad Zeros To Length 12 Pad Zeros To Length 13 Pad Zeros To Length 14 Pad Zeros To Length 15 Pad Zeros To Length 16 Pad Zeros To Length 17 Advanced Data Formatting 15 - 41 Pad Data with Zeros (continued) Pad Zeros To Length 18 Pad Zeros To Length 19 Pad Zeros To Length 20 Pad Zeros To Length 21 Pad Zeros To Length 22 Pad Zeros To Length 23 Pad Zeros To Length 24 15 - 42 Symbol DS6878 Product Reference Guide Pad Data with Zeros (continued) Pad Zeros To Length 25 Pad Zeros To Length 26 Pad Zeros To Length 27 Pad Zeros To Length 28 Pad Zeros To Length 29 Pad Zeros To Length 30 Stop Pad Zeros Advanced Data Formatting 15 - 43 Beeps Select a beep sequence for each ADF rule. Beep Once Beep Twice Beep Three Times Send Keystroke (Control Characters and Keyboard Characters) Control Characters Scan a Send bar code for the keystroke to send. Send Control 2 Send Control A Send Control B 15 - 44 Symbol DS6878 Product Reference Guide Control Characters (continued) Send Control C Send Control D Send Control E Send Control F Send Control G Send Control H Send Control I Advanced Data Formatting 15 - 45 Control Characters (continued) Send Control J Send Control K Send Control L Send Control M Send Control N Send Control O Send Control P 15 - 46 Symbol DS6878 Product Reference Guide Control Characters (continued) Send Control Q Send Control R Send Control S Send Control T Send Control U Send Control V Send Control W Advanced Data Formatting 15 - 47 Control Characters (continued) Send Control X Send Control Y Send Control Z Send Control [ Send Control \ Send Control ] 15 - 48 Symbol DS6878 Product Reference Guide Control Characters (continued) Send Control 6 Send Control - Keyboard Characters Scan a Send bar code for the keyboard characters to send. Send Space Send ! Send “ Send # Advanced Data Formatting 15 - 49 Keyboard Characters (continued) Send $ Send % Send & Send ‘ Send ( Send ) Send * 15 - 50 Symbol DS6878 Product Reference Guide Keyboard Characters (continued) Send + Send , Send - Send . Send / Send 0 Send 1 Advanced Data Formatting 15 - 51 Keyboard Characters (continued) Send 2 Send 3 Send 4 Send 5 Send 6 Send 7 Send 8 15 - 52 Symbol DS6878 Product Reference Guide Keyboard Characters (continued) Send 9 Send : Send ; Send < Send = Send > Send ? Advanced Data Formatting 15 - 53 Keyboard Characters (continued) Send @ Send A Send B Send C Send D Send E Send F 15 - 54 Symbol DS6878 Product Reference Guide Keyboard Characters (continued) Send G Send H Send I Send J Send K Send L Send M Advanced Data Formatting 15 - 55 Keyboard Characters (continued) Send N Send O Send P Send Q Send R Send S Send T 15 - 56 Symbol DS6878 Product Reference Guide Keyboard Characters (continued) Send U Send V Send W Send X Send Y Send Z Send [ Advanced Data Formatting 15 - 57 Keyboard Characters (continued) Send \ Send ] Send ^ Send _ Send ` Send a Send b 15 - 58 Symbol DS6878 Product Reference Guide Keyboard Characters (continued) Send c Send d Send e Send f Send g Send h Send i Advanced Data Formatting 15 - 59 Keyboard Characters (continued) Send j Send k Send l Send m Send n Send o Send p 15 - 60 Symbol DS6878 Product Reference Guide Keyboard Characters (continued) Send q Send r Send s Send t Send u Send v Send w Advanced Data Formatting 15 - 61 Keyboard Characters (continued) Send x Send y Send z Send { Send | Send } Send ~ Send ALT Characters 15 - 62 Symbol DS6878 Product Reference Guide Send Alt 2 Send Alt A Send Alt B Send Alt C Send Alt D Send Alt E Send Alt F Advanced Data Formatting 15 - 63 Send ALT Characters (continued) Send Alt G Send Alt H Send Alt I Send Alt J Send Alt K Send Alt L Send Alt M 15 - 64 Symbol DS6878 Product Reference Guide Send ALT Characters (continued) Send Alt N Send Alt O Send Alt P Send Alt Q Send Alt R Send Alt S Send Alt T Advanced Data Formatting 15 - 65 Send ALT Characters (continued) Send Alt U Send Alt V Send Alt W Send Alt X Send Alt Y Send Alt Z Send Alt [ 15 - 66 Symbol DS6878 Product Reference Guide Send ALT Characters (continued) Send Alt \ Send Alt ] Advanced Data Formatting 15 - 67 Send Keypad Characters Send Keypad * Send Keypad + Send Keypad - Send Keypad . Send Keypad / Send Keypad 0 Send Keypad 1 15 - 68 Symbol DS6878 Product Reference Guide Send Keypad Characters (continued) Send Keypad 2 Send Keypad 3 Send Keypad 4 Send Keypad 5 Send Keypad 6 Send Keypad 7 Send Keypad 8 Advanced Data Formatting 15 - 69 Send Keypad Characters (continued) Send Keypad 9 Send Keypad Enter Send Keypad Numlock Send Break Key Send Delete Key Send Page Up Key Send End Key 15 - 70 Symbol DS6878 Product Reference Guide Send Keypad Characters (continued) Send Page Down Key Send Pause Key Send Scroll Lock Key Send Backspace Key Send Tab Key Send Print Screen Key Send Insert Key Advanced Data Formatting 15 - 71 Send Keypad Characters (continued) Send Home Key Send Enter Key Send Escape Key Send Up Arrow Key Send Down Arrow Key Send Left Arrow Key Send Right Arrow Key 15 - 72 Symbol DS6878 Product Reference Guide Send Function Key Send F1 Key Send F2 Key Send F3 Key Send F4 Key Send F5 Key Send F6 Key Send F7 Key Advanced Data Formatting 15 - 73 Send Function Key (continued) Send F8 Key Send F9 Key Send F10 Key Send F11 Key Send F12 Key Send F13 Key Send F14 Key 15 - 74 Symbol DS6878 Product Reference Guide Send Function Key (continued) Send F15 Key Send F16 Key Send F17 Key Send F18 Key Send F19 Key Send F20 Key Send F21 Key Advanced Data Formatting 15 - 75 Send Function Key (continued) Send F22 Key Send F23 Key Send F24 Key Send PF1 Key Send PF2 Key Send PF3 Key Send PF4 Key 15 - 76 Symbol DS6878 Product Reference Guide Send Function Key (continued) Send PF5 Key Send PF6 Key Send PF7 Key Send PF8 Key Send PF9 Key Send PF10 Key Send PF11 Key Advanced Data Formatting 15 - 77 Send Function Key (continued) Send PF12 Key Send PF13 Key Send PF14 Key Send PF15 Key Send PF16 Key Send PF17 Key Send PF18 Key 15 - 78 Symbol DS6878 Product Reference Guide Send Function Key (continued) Send PF19 Key Send PF20 Key Send PF21 Key Send PF22 Key Send PF23 Key Send PF24 Key Send PF25 Key Advanced Data Formatting 15 - 79 Send Function Key (continued) Send PF26 Key Send PF27 Key Send PF28 Key Send PF29 Key Send PF30 Key Send Right Control Key The “Send Right Control Key” action will send a tap (press and release) of the Right Control Key. Send Right Control Key 15 - 80 Symbol DS6878 Product Reference Guide Send Graphic User Interface (GUI) Characters The Send Graphic User Interface Character actions taps the specified key while holding the System Dependent Graphic User Interface (GUI) Key. The definition of the Graphic User Interface key depends on the attached system. Send GUI 0 Send GUI 1 Send GUI 2 Send GUI 3 Send GUI 4 Send GUI 5 Advanced Data Formatting 15 - 81 Send Graphic User Interface (GUI) Characters (continued) Send GUI 6 Send GUI 7 Send GUI 8 Send GUI 9 Send GUI A Send GUI B Send GUI C 15 - 82 Symbol DS6878 Product Reference Guide Send Graphic User Interface (GUI) Characters (continued) Send GUI D Send GUI E Send GUI F Send GUI G Send GUI H Send GUI I Send GUI J Advanced Data Formatting 15 - 83 Send Graphic User Interface (GUI) Characters (continued) Send GUI K Send GUI L Send GUI M Send GUI N Send GUI O Send GUI P Send GUI Q 15 - 84 Symbol DS6878 Product Reference Guide Send Graphic User Interface (GUI) Characters (continued) Send GUI R Send GUI S Send GUI T Send GUI U Send GUI V Send GUI W Send GUI X Advanced Data Formatting 15 - 85 Send Graphic User Interface (GUI) Characters (continued) Send GUI Y Send GUI Z Turn On/Off Rule Sets Use these bar codes to turn rule sets on and off. Turn On Rule Set 1 Turn On Rule Set 2 Turn On Rule Set 3 Turn On Rule Set 4 15 - 86 Symbol DS6878 Product Reference Guide Turn On/Off Rule Sets (continued) Use these bar codes to turn rule sets on and off. Turn Off Rule Set 1 Turn Off Rule Set 2 Turn Off Rule Set 3 Turn Off Rule Set 4 Advanced Data Formatting 15 - 87 Alphanumeric Keyboard Space (Single Quote) (Dash) 15 - 88 Symbol DS6878 Product Reference Guide Alphanumeric Keyboard (continued) (Comma) “ ‘ Advanced Data Formatting 15 - 89 Alphanumeric Keyboard (continued) 15 - 90 Symbol DS6878 Product Reference Guide Alphanumeric Keyboard (continued) (Underscore) Advanced Data Formatting 15 - 91 Alphanumeric Keyboard (continued) NOTEDo not confuse the numeric bar codes below with those on the numeric keypad. 15 - 92 Symbol DS6878 Product Reference Guide Alphanumeric Keyboard (continued) Advanced Data Formatting 15 - 93 Alphanumeric Keyboard (continued) 15 - 94 Symbol DS6878 Product Reference Guide Alphanumeric Keyboard (continued) Advanced Data Formatting 15 - 95 Alphanumeric Keyboard (continued) 15 - 96 Symbol DS6878 Product Reference Guide Alphanumeric Keyboard (continued) Cancel End of Message Advanced Data Formatting 15 - 97 Alphanumeric Keyboard (continued) 15 - 98 Symbol DS6878 Product Reference Guide Alphanumeric Keyboard (continued) Advanced Data Formatting 15 - 99 Alphanumeric Keyboard (continued) 15 - 100Symbol DS6878 Product Reference Guide Alphanumeric Keyboard (continued)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2010:02:26 11:11:42Z Creator : FrameMaker 8.0 Modify Date : 2010:02:26 13:17:56-05:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : FrameMaker 8.0 Metadata Date : 2010:02:26 13:17:56-05:00 Producer : Acrobat Distiller 9.0.0 (Windows) Format : application/pdf Title : Symbol DS6878 Product Reference Guide Document ID : uuid:3fbe028a-6e02-4005-9cd2-7d9676aac81b Instance ID : uuid:9954faa3-ba27-4b1f-8675-ed972d68cc26 Page Mode : UseOutlines Page Count : 238EXIF Metadata provided by EXIF.tools