Zebra Technologies TW5 2x2 802.11n PCIe MODULE User Manual MN000030A01 RevisionA Updates
Zebra Technologies Corporation 2x2 802.11n PCIe MODULE MN000030A01 RevisionA Updates
User Manual
TS-524 management VLANs Antenna configuration Transmit power settings* Operating frequencies* Data rates Standards Medium Pass through phone port Uplink UTP LAN Ethernet port Wireless Interface 2 x IEEE 802.3 10/100/1000MB auto-sensing RJ-45 Telnet, SSH, HTTPS, Serial Console 802.1 Q tagged VLANS, access or trunk Two internal omni-directional, 1x2 or 2x2 MIMO operation 3dBi peak @ 2.4GHz 1dBm to 20dBm, in 1dBm increments 2.4GHz: 2400 to 2483.5MHz 5GHz: 5150 to 5250MHz, 5725 to 5850MHz 802.11b: 1,2,5.5, 11Mbps 802.11g: 6, 9, 12,18, 24, 36, 48, 54Mbps 802.11a: 6, 9, 12,18, 24, 36, 48, 54Mbps 802.11n: MCS 0 to 15 up to 300Mbps 802.11a, 802.11b, 802.11g, 802.11n draft 2.0, 802.11i, 802.11-2007 DSSS, OFDM, MIMO Filtered RJ11 port 1 x RJ11 UTP, VDSL2 2 x IEEE 802.3 10/100MB auto-sensing via RJ-45 Single radio; 802.11a/b/g/n; 2.4GHz or 5GHz TS-524 and TW-5xx Specifications TS-524 uplink ports 1 x RJ21 for PBX connection, 1 x RJ21 for downstream VDSL2 (3) If installing a filter on a bathroom phone, use the unterminated filter. Remove the bathroom wall plate and terminate the filter in the wall box using wire beans. The terminated filter has a clipped RJ11 connector. This is purposely done to comply with EN60950 requirements. Use a small flat blade screwdriver to lift the tab if attempting to remove the filter. (4) 4. Connect the supplied 10cm cable between the TW-51x bottom mounted RJ11 jack and the existing RJ11 jack. 5. Hook the bottom tabs on the mounting adapter to the TW-51x. Rotate and snap the TW-51x onto the adapter. CAUTION Do not over tighten. 3. Tighten the screws until the mounting adapter is securely attached. 1. Loosen the screws on the existing wall plate to create a gap of 6mm (1/4 in). 2. Attach the mounting adapter using the keyhole slots. Installing the TW-51x WallPlate Introduction The Motorola TW-51x Series Wired/Wireless WallPlate is designed for multi-tenant buildings such as hotels, healthcare facilities, apartments, and dormitory housing. The TW-51x is designed to leverage the in-building telephone wiring to deploy Ethernet and wireless LAN networks without the effort and expense of re-wiring with structured cabling. This installation guide applies to TS-524 (P/N TS-0524-WR), TW-511 (P/N TW-0511-60010-US, -EU, -WR), and TW-510 (P/N TW-0510-WR). Document Conventions TS-524 UTP ports * Operating frequencies and transmit power settings depend on national regulatory limits. (2) The TW-5x Wallplate features a built-in Plain Old Telephone Setvice (POTS) and Line Power filter for the desk phone. Install an in-line filter on all other phone jacks that will have a phone connected. 192.168.1.3 Default IP Address config password admincountry-code hostname interface vlan1 ip-address 192.168.1.1/24 wlan Guest exit int dsl1-24 no shutdown int radio1-24.1 channel 6 power 18 wlan Guest no shutdown exit Enter the following commands: Username: admin Password: motorola (5) Log in to the system using Telnet, SSH, HTTP, or Serial Console using the default username and password: Speed: 19200 Data Bits: 8 Parity: None Stop Bit: 1 Flow Control: None Serial Console Connection The following will enable all ports and configure one wireless LAN: Network Configuration (TS-524) TS-524 Switch and TW-5xx WallPlate Installation Guide NOTE Tips, hints, or special requirements that you should take note of. CAUTION Care is required. Disregarding a caution can result in data loss or equipment malfunction. WARNING! Indicates a condition or procedure that could result in personal injury or equipment damage. The following graphical alerts are used in this document to indicate notable situations: Warnings • This equipment should only be installed by qualified professional installers. • Read all installation instructions and site survey reports, and verify correct equipment installation before installing this equipment. • Remove jewelry and watches before installing this equipment. • Verify proper wiring and grounding for each installation location . • Verify there is adequate ventilation around the device, and that ambient temperatures meet equipment operation specifications (0° to 40° Celsius / 32° to 104° Fahrenheit). (1) Installing In-line Filters (6) This device is approved under Motorola Solutions, Inc. This guide applies to Model Numbers: TS-524, TW-510, and TW-511. All Motorola devices are designed to be compliant with rules and regulations in locations where they are sold and will be labeled as required. Local language translations are available at the following website: http://www.motorolasolutions.com/support. Any changes or modifications to Motorola Solutions equipment, not expressly approved by Motorola Solutions, could void the user's authority to operate the equipment. When Motorola Solutions devices are professionally installed, the Radio Frequency Output Power will not exceed the maximum allowable limit for the country of operation. Antennas: Use only the supplied or an approved replacement antenna. Unauthorized antennas, modifications, or attachments could cause damage and may violate regulations. Radio Modules The TW-511 contains an approved radio module. This module is identified below: Motorola Solutions, Inc. 802.11 a/b/g/n WLAN, Type: TW-5 Wireless Device Country Approvals (TW-511 only) Regulatory markings, subject to certification, are applied to the device signifying the radio(s) is/are approved for use in the following countries: United States, Canada, Japan, China, S. Korea, Australia, and Europe. Please refer to the Declaration of Conformity (DoC) for details of other country markings. This is available at http://www.motorolasolutions.com/doc. Note: Europe includes, Austria, Belgium, Bulgaria, Czech Republic, Cyprus, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovak Republic, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Regulatory Information interface dsl1-24 line-power write memory To enable line power, enter the following commands into the CLI: Line power should be enabled after the filters and TW-51x WallPlate have been installed. Line power is safe for use with telephony equipment but it will ring the phones if the filters are not installed first. Enabling Line Power MOTOROLA SOLUTIONS INC. 1303 E. ALGONQUIN ROAD SCHAUMBURG, IL 60196 http://www.motorolasolutions.com MN000030A01 July 2013 Revision A Wireless devices transmit radio frequency energy and may affect medical electrical equipment. When installed adjacent to other equipment, it is advised to verify that the adjacent equipment is not adversely affected. Pacemakers Pacemaker manufacturers recommended that a minimum of 15cm (6 inches) be maintained between a handheld wireless device and a pacemaker to avoid potential interference with the pacemaker. These recommendations are consistent with independent research and recommendations by Wireless Technology Research. Persons with Pacemakers: • Should ALWAYS keep the device more than 15cm (6 inches) from their pacemaker when turned ON. • Should not carry the device in a breast pocket. • Should use the ear furthest from the pacemaker to minimize the potential for interference. • If you have any reason to suspect that interference is taking place, turn OFF your device. (8) Safety in Hospitals TW-510 and TW-511 Wallplates When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1. Do not use this product near water, for example, near a bath tub, wash bowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool. 2. Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning. 3. Do not use the telephone to report a gas leak in the vicinity of the leak. Warnings for Use of Wireless Devices Please observe all warning notices with regard to the usage of wireless devices. Potentially Hazardous Atmospheres - Fixed Installations You are reminded of the need to observe restrictions on the use of radio devices in fuel depots, chemical plants etc. and areas where the air contains chemicals or particles (such as grain, dust, or metal powders). Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g.,use of power strips). Product designed to be used below 2000 meters altitude. TS-524 Only WARNING: For installation only in a Restricted Access Location by trained service personnel. WARNING: Equipment must be connected to an earthed mains socket-outlet. WARNING: To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. WARNING: Voltages present which are above TNV-3 (POTS) limits. A cover must be installed over the punch down blocks with a HV (High Voltage) warning label (supplied). WARNING: The maximum operating ambient temperature is 40 degrees Celcius. When installing the Switch in an equipment rack, consider the following potential hazards: Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than the room ambient. Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer's maximum rated ambient temperature (Tmra). (7) General Safety Warnings Industry Canada Statement: Caution: The device for the band 5150-5250 MHz is only for indoor usage to reduce potential for harmful interference to co-Channel mobile satellite systems. High power radars are allocated as primary users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars could cause interference and/or damage to LE-LAN devices. Avertissement: Le dispositive fonctionnant dans la bande 5150-5250 MHz est réservé uniquement pour une utilisation à l'intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux. Les utilisateurs de radars de haute puissance sont désignés utilisateurs principaux (c.-à-d., qu'ils ont la priorité) pour les bands 5250-5350 MHz et 5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL 2.4 GHz Only The available channels for 802.11 b/g operation in the US are Channels 1 to 11. The range of channels is limited by firmware. Health and Safety Recommendations Country Selection Select only the country in which you are using the device. Any other selection will make the operation of this device illegal. The US version of the Access Point will operate only if US country code is selected. The US version will be sold / used in the US protectorates: American Samoa, Guam, Northern Marianas, Puerto Rico, US Virgin Islands. Frequency of Operation - FCC and IC 5 GHz Only The use in the UNII (Unlicensed National Information Infrastructure) band 1 (5150-5250 MHz) is restricted to Indoor Use Only; any other use will make the operation of this device illegal. Operation of the device without regulatory approval is illegal. (10) WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. The use of 2.4GHz RLAN's, for use through the EEA, have the following restrictions: • Maximum radiated transmit power of 100 mW EIRP in the frequency range 2.400 -2.4835 GHz. • Italy requires a user license for outside usage. Statement of Compliance for Wireless Devices (TW-511 Only) Motorola hereby declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A Declaration of Conformity may be obtained from http://www.motorolasolutions.com/doc Statement of Compliance for Non-Wireless Devices (TS-524 and TW-510) Motorola hereby declares that this device is in compliance with all the applicable Directives, 2004/108/EC and 2006/95/EC. A Declaration of Conformity may be obtained from http://www.motorolasolutions.com/doc Marking and European Economic Area (EEA) Label Marking: The Term "IC:" before the radio certification only signifies that Industry Canada technical specifications were met. Radio Frequency Interference Requirements - Canada This Class A digital apparatus complies with Canadian ICES-003. Radio Transmitters - (TW-511 Only) For RLAN Devices: The use of 5 GHz RLAN's, for use in Canada, have the following restrictions: • Restricted Band 5.60 - 5.65 GHz L'utilisation de RLAN de 5 GHz, pour utilisation au Canada est soumise aux restrictions suivantes: • Bande Restreinte de 5,60 à 5,65 GHz This device complies with RSS 210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Ce dispositif est conforme à la norme CNR-210 d'Industrie Canada applicable aux appareils radio exempts de licence. Son fonctionnement est sujet aux deux conditions suivantes: (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Radio Transmitters (Part 15) - (TW-511 Only) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The use of 5 GHz WLAN's, for use in the US , have the following restrictions • Notched Band 5.60 - 5.65 GHz (9) Safety Information Reducing RF Exposure - Use Properly Only operate this device in accordance with the instructions supplied. International (TW-511 Only) The device complies with internationally recognized standards covering human exposure to electromagnetic fields from radio devices. For information on "International" human exposure to electromagnetic fields refer to the Motorola Declaration of Conformity (DoC) at http://www.motorolasolutions.com/doc For further information on the safety of RF energy from wireless devices - see http://responsibility.motorolasolutions.com/index.php/ourapproach/wirelesscommhealth EU (TW-511 Only) Remote and Standalone Antenna Configurations To comply with EU RF exposure requirements, antennas that are mounted externally at remote locations or operating near users at stand-alone desktop of similar configurations must operate with a minimum separation distance of 20 cm from all persons. US and Canada (TW-511 Only) Co-located statement To comply with FCC RF exposure compliance requirement, the antenna used for this transmitter must not be co-located or operating in conjunction with any other transmitter/antenna except those already approved in this filling. Remote and Standalone Antenna Confiugrations To comply with FCC RF exposure requirements, antennas that are mounted externally at remote locations or operating near users at stand-alone desktop of similar configurations must operate with a minimum separation distance of 20 cm from all persons. Radio Frequency Interference Requirements - FCC Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. RF Exposure Guidelines (TW-511 Only) Other Medical Devices Please consult your physician or the manufacturer of the medical device, to determine if the operation of your wireless product may interfere with the medical device. Turkish WEEE Statement of Compliance (12) Slovenski: Za kupce v EU: vsi izdelki se morajo po poteku življenjske dobe vrniti podjetju Motorola za reciklažo. Za informacije o vra?ilu izdelka obiš?ite: http://www.motorola.com/recycling/weee. Dansk: Til kunder i EU: Alle produkter skal returneres til Motorola til recirkulering, når de er udtjent. Læs oplysningerne om returnering af produkter på: http://www.motorola.com/recycling/weee. Suomi: Asiakkaat Euroopan unionin alueella: Kaikki tuotteet on palautettava kierrätettäväksi Motorola-yhtiöön, kun tuotetta ei enää käytetä. Lisätietoja tuotteen palauttamisesta on osoitteessa http://www.motorola.com/ recycling/weee. Svenska: För kunder inom EU: Alla produkter som uppnått sin livslängd måste returneras till Motorola för återvinning. Information om hur du returnerar produkten finns på http://www.motorola.com/recycling/weee. Magyar: Az EU-ban vásárlóknak: Minden tönkrement terméket a Motorola vállalathoz kell eljuttatni újrahasznosítás céljából. A termék visszajuttatásának módjával kapcsolatos tudnivalókért látogasson el a http:/ /www.motorola.com/recycling/weee weboldalra. (11) Eesti: EL klientidele: kõik tooted tuleb nende eluea lõppedes tagastada taaskasutamise eesmärgil Motorola'ile. Lisainformatsiooni saamiseks toote tagastamise kohta külastage palun aadressi: http://www.motorola.com/ recycling/weee. Français: Clients de l'Union Européenne: Tous les produits en fin de cycle de vie doivent être retournés à Motorola pour recyclage. Pour de plus amples informations sur le retour de produits, consultez : http:// www.motorola.com/recycling/weee. Español: Para clientes en la Unión Europea: todos los productos deberán entregarse a Motorola al final de su ciclo de vida para que sean reciclados. Si desea más información sobre cómo devolver un producto, visite: http:/ /www.motorola.com/recycling/weee. Bulgarish: За клиенти от ЕС: След края на полезния им живот всички продукти трябва да се връщат на Motorola за рециклиране. За информация относно връщането на продукти, моля отидете на адрес: http://www.motorola.com/recycling/weee. Deutsch: Für Kunden innerhalb der EU: Alle Produkte müssen am Ende ihrer Lebensdauer zum Recycling an Motorola zurückgesandt werden. Informationen zur Rücksendung von Produkten finden Sie unter http:// www.motorola.com/recycling/weee. Italiano: per i clienti dell'UE: tutti i prodotti che sono giunti al termine del rispettivo ciclo di vita devono essere restituiti a Motorola al fine di consentirne il riciclaggio. Per informazioni sulle modalità di restituzione, visitare il seguente sito Web: http://www.motorola.com/recycling/weee. Português: Para clientes da UE: todos os produtos no fim de vida devem ser devolvidos à Motorola para reciclagem. Para obter informações sobre como devolver o produto, visite: http://www.motorola.com/ recycling/weee. Nederlands: Voor klanten in de EU: alle producten dienen aan het einde van hun levensduur naar Motorola te worden teruggezonden voor recycling. Raadpleeg http://www.motorola.com/recycling/weee voor meer informatie over het terugzenden van producten. Polski: Klienci z obszaru Unii Europejskiej: Produkty wycofane z eksploatacji nale¿y zwróciæ do firmy Motorola w celu ich utylizacji. Informacje na temat zwrotu produktów znajduj¹ siê na stronie internetowej http:// www.motorola.com/recycling/weee. English: For EU Customers: All products at the end of their life must be returned to Motorola for recycling. For information on how to return product, please go to: http://www.motorola.com/recycling/weee. Waste Electrical and Electronic Equipment (WEEE) (14) Website: http://www.motorolasolutions.com Telephone (International): +1-631-738-5200 Telephone (North America): 1-800-722-6234 Obtain additional information by contacting Motorola Solutions at: General Information http://supportcentral.motorolasolutions.com/support/product/manuals.do Manuals provides information and online assistance including developer tools, software downloads, product manuals and online repair requests. http://supportcentral.motorolasolutions.com/ The Motorola Solutions Support Central Web site, located at: Customer Support Web Sites Motorola Solutions responds to calls by e-mail, telephone, or fax within the time limits set forth in support agreements. If you purchased your product from a Motorola Solutions business partner, contact that business partner for support. • Software type and version number • Model number or product name • Serial number of the unit When contacting Motorola Solutions support, please provide the following information: Contact information is available at: http://www.motorolasolutions.com/support. If you have a problem with your equipment, contact support for your region. Motorola Solutions Support Center (13) Other Countries Australia Use of 5 GHz RLAN's in Australia is restricted in the following band 5.50 - 5.65GHz. Brazil Declarações Regulamentares para TW-511 - Brazil Nota: A marca de certificação se aplica ao Transceptor, modelo TW-511. Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário. Para maiores informações sobre ANATEL consulte o site: www.anatel.gov.br Mexico Mexico Restrict Frequency Range to: 2.450 - 2.4835 GHz. La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada. Chinese Warning Statement for Class A ITE Japan (VCCI) - Voluntary Control Council for Interference
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : rxb468 Create Date : 2003:05:06 15:03:59Z Modify Date : 2013:07:04 17:48:57+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : FrameMaker 9.0 Metadata Date : 2013:07:04 17:48:57+08:00 Producer : Acrobat Distiller 9.0.0 (Windows) Format : application/pdf Title : MN000030A01_RevisionA_Updates.fm Creator : rxb468 Document ID : uuid:a5b22037-efa4-4af5-b72e-c29cb1f7c78d Instance ID : uuid:c3a94bfa-0ae9-42cc-a9d8-ae134d99f8c6 Page Mode : UseNone Page Count : 2EXIF Metadata provided by EXIF.tools