Zebra Technologies WND3100 DartWand Module User Manual UWD 3100 DartWand Software User Guide
Zebra Technologies Corporation DartWand Module UWD 3100 DartWand Software User Guide
User Manual
UWD-3100 DartWand Software User Guide Beta 1.0 1500-0710 CONFIDENTIAL INFORMATION OF Zebra Enterprise Solutions, A ZEBRA TECHNOLOGIES COMPANY UNAUTHORIZED USE IS STRICTLY PROHIBITED. DartWand, DartTags, and Sapphire are trademarks of Zebra Enterprise Solutions, A Zebra Technologies Company. Š Zebra Enterprise Solutions, A Zebra Technologies Company 1988 - 2010. All rights reserved. This document has been made available as part of the license that has been granted to an authorized user of Zebra Enterprise Solutions software. Use of this documentation is subject to the terms and limitations of that license agreement. This documentation describes all functionality that can be licensed for this product. Not all functionality described in this documentation may be available to you depending on your license agreement. If you are not aware of the relevant terms of your license agreement, contact sales at Zebra Enterprise Solutions. This document is protected by copyright and by the licenseeâs agreement to maintain the confidentiality of the content of this document as provided in the license agreement for the software. Liability Disclaimer Zebra Enterprise Solutions takes steps to ensure that its published documentation is correct; however, errors do occur. Zebra Enterprise Solutions reserves the right to correct any such errors and disclaims liability resulting therefrom. Limitation of Liability In no event shall Zebra Enterprise Solutions or any of their licensors be liable to You for any of the following (collectively referred to as "Injuries"): injuries (including death) or damages to persons or to property, or damages of any other kind, direct, indirect, special, exemplary, incidental or consequential, including, but not limited to, loss of use, lost profits, lost revenues, loss of data, replacement costs, debt service or rental payments, or damages owing by You to others, whether arising out of contract, tort, strict liability or otherwise, arising from or relating to the design, use or operation of these online materials, the Software, Documentation, Hardware, or from any Services provided by Zebra Enterprise Solutions (whether or not Zebra Enterprise Solutions or its licensors knew or should have known of the possibility of any such Injuries) even if a remedy set forth herein is found to have failed of its essential purpose. Zebra Enterprise Solutions, A Zebra Technologies Company 1000 Broadway, Suite 150 Oakland CA 94607 USA www.zebra.com/zes Tel: +1 510 267 5000 Fax: +1 510 267 5100 Contents DartWand basics Setting up DartWand Install the DartWand software ................................................................................7 Install the barcode scanner ......................................................................................8 Connect the DartWand hardware...........................................................................8 Start the DartWand software ...................................................................................8 Viewing UWB tag inventory Configuring tags 11 Create a tag list ........................................................................................................13 Enter tag IDs manually ...................................................................................13 Use the Find Tag button to add tag IDs ........................................................13 Scan the tag barcode to add tag IDs ..............................................................13 Scan the box barcode to add tag IDs .............................................................13 Working with files 15 Create and load tag list files ..................................................................................15 Create and load config files ...................................................................................15 Working with tables 17 Troubleshooting 19 Regulatory Information 21 US Regulatory Information ...................................................................................21 Canada Regulatory Information ...........................................................................22 RF Notice ..................................................................................................................22 EU Regulatory Information ...................................................................................22 Specifications Appendix I: Estimated UWB Range 23 25 : UWD-3100 DartWand Software User Guide 1.0 iii 1 DartWand basics Sapphire tags and DartTags are battery powered devices that periodically transmit their unique ID over Ultra Wide Band (UWB) radio frequencies. Sapphire tags support a single transmission rate that is set at the factory, whereas the rate of DartTags is user-configurable. A typical UWD-3100 DartWand system consists of a computer with DartWand software, DartWand USB cable, and an optional barcode scanner. The DartWand can configure the blink rate of DartTags. In addition, the DartWand can display inventory of nearby Sapphire or DartTags that are transmitting UWB. The UWD-3100 DartWand hardware contains low frequency (LF) coils for transmitting configuration commands to DartTags. The range of this magnetic communication is 1 or 2 feet. The UWD-3100 DartWand also contains a UWB receiver that has a range from several inches up to 500 feet, depending on the software range setting and on environmental factors. The DartWand software consists of USB device drivers plus an application for configuring tags and performing UWB inventories. An optional barcode scanner can be used to scan the barcode shipping label on the individual tags, or the barcode label on a box of tags. : UWD-3100 DartWand Software User Guide 1.0 DartWand basics : UWD-3100 DartWand Software User Guide 1.0 2 Setting up DartWand To use DartWand, you need: A computer with one available USB 2.0 port and one of the following operating systems: MicrosoftÂŽ WindowsÂŽ 2000, XP, 7, or Server 2003 A minimum screen resolution of 800 x 600 UWD-3100 DartWand hardware with a USB cable DartWand software installation files Optionally, a barcode scanner capable of decoding 1D and optionally 2D barcodes. The barcode scanner may require an additional USB 2.0 port. One or more DartTags In This Section Install the DartWand software ......................................................................... 7 Install the barcode scanner ............................................................................... 8 Connect the DartWand hardware .................................................................... 8 Start the DartWand software ............................................................................ 8 Install the DartWand software Installing the DartWand software is the first step in setting up DartWand. To install the DartWand software: Copy the folder containing the installation files to a temporary folder on your machine. Run the setup.exe file. Follow the prompts in the DartWand installer. This will also install USB drivers for communication with DartWand hardware. Click Finish. The DartWand installer finalizes the installation and places a DartWand icon on your desktop. : UWD-3100 DartWand Software User Guide 1.0 Setting up DartWand Install the barcode scanner Install the barcode scanner Installing a barcode scanner is optional. To install the barcode scanner: Install the scanner per manufacturerâs instructions. Many USB scanners do not require a driver and you can just plug them in to a USB port on your machine. If needed, configure the barcode scanner to append a carriage return (CR suffix) after each scan. Connect the DartWand hardware Before you connect the DartWand hardware, make sure you have installed the DartWand software. To connect to the DartWand hardware: Connect the DartWand hardware to the computer using the supplied USB cable. Make sure to use a powered USB port. Do not connect to an unpowered USB hub. Start the DartWand software When you have installed both DartWand software and hardware, you can run the software. To start the DartWand software: Double-click the DartWand shortcut on your desktop. : UWD-3100 DartWand Software User Guide 1.0 3 Viewing UWB tag inventory The Inventory tab displays a table view that provides information on all tags transmitting UWB in range of the DartWand. To receive an accurate list, you need to specify the range of the UWB receiver. The minimum setting (1) only shows tags within a few inches of the reader. The maximum setting (25) shows tags transmitting within maximum range; this can be over 500 feet, depending on the environment. For information on the estimated DartWand UWB range, see Appendix I (on page 25). The following table describes the table columns available on the Inventory tab. Column Name Description TagID The unique ID for the tag. This column is displayed in Hex, exactly as it appears on the printed tag label. USB Family Indicates if the tag is a Sapphire tag (1st generation UWB tag) or a DartTag LastSeen The time when the software last received this tag. battery The current battery level. This can be any value from 15 to 0, where 0 is the lowest battery level. Inferred Frequency The computed tag blink rate, in Hz (blinks per second). This value is computed using (Hz) approximately a two-second window. This is an optional field. See also Working with tables (on page 17). Avg Rate (Hz) The computed tag blink rate, in Hz (blinks per second). This value is computed using the total number of blinks received divided by the total time. To clear the tag inventory and restart this calculation, click the Clear button To view a list of tags transmitting UWB in range of the DartWand: In DartWand, on the Inventory tab, from the UWB Range list, select the desired range according to the sensitivity of the UWB receiver. In the Filter field, type a TagID to display only a subset of the tags in the list. You may type part or all of the TagID. The table content refreshes as you type. To clear the filter and display all tags, click the X button next to the Filter field. Click above the table to clear the tag inventory in memory. : UWD-3100 DartWand Software User Guide 1.0 Viewing UWB tag inventory 10 Select AutoRefresh to have the screen update automatically. : UWD-3100 DartWand Software User Guide 1.0 4 Configuring tags When you have started the DartWand software (on page 8), you are ready to configure the tags. To configure a tag: On the Config tab, in the Tag List field, enter one tag per line. For different methods of adding tags to the list, see Create a tag list (on page 13). Under Config Actions: From the Rate list, select a requested UWB blink rate for the tag, or accept the current setting. : UWD-3100 DartWand Software User Guide 1.0 11 Configuring tags Start the DartWand software From the Blink list, select On or OFF to enable or disable UWB blinks, or accept the current setting. Position the tag close to the UWD-3100 DartWand hardware and click Go. The status report adds a record for each tag. The Config tab displays the number of acknowledged tags at the bottom right. The Configuring Tags dialog box indicates the configuration progress. In the Configuring Tags dialog box, do one of the following: If all tags were configured successfully, the dialog box displays a green check mark and the success rate, in percent. In this case, click OK. If one or more tags failed during the configuration, the dialog box turns yellow and displays a list of the tags that failed. In this case, reposition the tags or the DartWand, and then click Retry. When all tags were configured successfully, click OK. In This Section Create a tag list ................................................................................................. 13 12 : UWD-3100 DartWand Software User Guide 1.0 Configuring tags Create a tag list Create a tag list You can add tags to the tag list by: Typing (on page 13) Sending an LF broadcast message by clicking the Find Tags button (on page 13) Scanning a tag barcode (on page 13) or box barcode (on page 13) Enter tag IDs manually You can manually add tags to the tag list by entering the individual tag IDs. To enter tagIDs manually: On Config tab, click Type one or more tag IDs exactly as shown on the tag label, including any leading zeros, putting each tag on a separate line. to clear the tag list. Use the Find Tag button to add tag IDs You can use the Find Tag button to add tag IDs to the list. When you click this button, DartWand sends a low frequency (LF) broadcast message that detects which tags are in LF range. To add tag IDs by using the Find Tag button: Position the tags close to the UWD-3100 hardware. On the Config tab, click Find Tags. The UWB Tag Scan dialog box opens. When the DartWand software has detected all tags in range, the UWB Tag dialog box closes and the tags appear in the Tag List field. Scan the tag barcode to add tag IDs You can configure several tags at once by scanning their barcode. To add tagIDs by scanning the tag barcode: Click the Config tab. Use the barcode scanner to scan the 2D barcode on the tag. The tag ID should appear in the Tag List field. Repeat Step 2 for up to 100 tags. Scan the box barcode to add tag IDs ZES typically ships boxes that contain 20 tags. Each box comes with a large 2D barcode shipping label that contains a list of every individual tag ID. Scanning this barcode quickly adds all 20 tags to the tag list. To add tag IDs by scanning the box barcode: Click the Config tab. Use the barcode scanner to scan the large 2D barcode on the box label. : UWD-3100 DartWand Software User Guide 1.0 13 Configuring tags Create a tag list 14 : UWD-3100 DartWand Software User Guide 1.0 5 Working with files You can use the DartWand software to create tag list files (on page 15) and configuration files (on page 15) as a record of received and configured tags. In This Section Create and load tag list files............................................................................ 15 Create and load config files ............................................................................ 15 Create and load tag list files You can use the DartWand software to create and load tag list files. Each tag list file contains a list of tag IDs, with one tag ID per line. This is helpful if you have a group of tags you usually configure together. The file ensures consistency because it eliminates the need for scanning each individual tag ID. To create a tag list file: On the Config tab, click the Save icon In the Save Tag List dialog box, type a filename and click Save. above the Tag List field. ZES recommends using a descriptive name for Tag List files, such as Forklift Tag List.txt. Alternatively, you can use a text editor such as Notepad to create a Tag List file. To do so, enter one tag ID per line; then save the file with the extension .tl. To load a tag list file: On the Config tab, click the Open icon In the Open dialog box, browse to and select the file you want to open. Click Open. above the Tag List field. Create and load config files You can use the DartWand software to create new and load previously created config files. Each config file contains a pair of Blink Rate and Blink Enabled configuration settings for tag programing, such as a Blink Rate = 0.5 Hz and Blink = ON. Keeping all setting information in a config file reduces the risk of entering or maintaining incorrect settings. : UWD-3100 DartWand Software User Guide 1.0 15 Working with files Create and load config files To create a config file: On the Config tab, in the Config Actions area, click the Save icon In the Save dialog box, type a file name and click Save. ZES recommends using a descriptive name for this file, such as Forklift Tag Config.cfg. To load a config file: On the Config tab, in the Config Actions area, click the Open icon In the Open dialog box, browse to and select the file you want to open. Click Open. 16 : UWD-3100 DartWand Software User Guide 1.0 6 Working with tables Both tabs in the DartWand software user interface include a table: The Inventory table on the Inventory tab displays all tags in the UWB receive range. The Status table on the Config tab displays the status of the tags recently programmed. The following table describes how you can use and configure these tables. Task Copy the table content to the clipboard Instructions 1. Clear the Auto Refresh check box (Inventory tab only). 2. Right-click the table and select one of the following: ⢠Copy Table: Copies the entire table content to the clipboard ⢠Copy Selection: Copies the selected rows to the clipboard ⢠Copy Cell: Copies the value of the last cell clicked Save the table content to file 3. Paste the copied data into any application, such as Microsoft Windows Excel. 1. Clear the Auto Refresh check box (Inventory tab only). 2. Click the Save icon 3. In the Save Status Report dialog box, provide the following information: above the table. ⢠File name: The name of the report ⢠Save as type: The file type, which can be plain text with tab delimiter between values (.txt), rich text (.rtf), HTML, or comma separated values (.csv) 4. Hide a table column Click Save. Do one of the following: ⢠Right-click a column header and clear the check mark from the column name. ⢠Press Ctrl and click the header of the column to be hidden. Show a table column Right-click a column header and select the column to show. Move a table column Drag a column header to the new position. Resize a table column 1. Move the pointer over the border between two columns so it changes to 2. Click and drag the border as required. Sort by a table column Click a column header to sort the table by this table. An arrow appears next to the column header. To reverse the sort order, click the column header again. : UWD-3100 DartWand Software User Guide 1.0 17 Working with tables 18 : UWD-3100 DartWand Software User Guide 1.0 7 Troubleshooting The following table suggests solutions to the most common problems. Problem The DartWand Installer does not complete or displays an error message. The Connect dialog box opens, displaying the following message: "The DartWand software is not communicating with the UWB Configurator. Please verify the device is connected via a USB port then click 'Connect'." Suggested Solution Make sure the USB driver is installed properly. To manually install the USB driver: 1. Open the folder containing the original DartWand software installer. 2. Open the Driver subfolder. 3. Double-click the CP210x_VCP_Win2K_XP_S2K3.exe file to run the driver installer. 1. Make sure a USB cable properly connects the DartWand hardware to the computer. 2. In the Connect dialog box, click Connect. 3. If this does not work, do the following: ⢠Click the Gear icon ⢠From the drop-down list, select the mapped COM port. ⢠Click Connect again. If this still does not work, try re-installing the DartWand drivers. Retry errors occur during tag configuration. On the Inventory tab, increase the UWB range. If the UWB range is set too low, DartWand does not detect UWB responses. See also Viewing UWB tag inventory (on page 9). : UWD-3100 DartWand Software User Guide 1.0 19 8 Regulatory Information This section provides the following regulatory information: US Regulatory Information (on page 21) Canada Regulatory Information (on page 22) RF Notice (on page 22) EU Regulatory Information (on page 22) In This Section US Regulatory Information............................................................................. 21 Canada Regulatory Information .................................................................... 22 RF Notice ........................................................................................................... 22 EU Regulatory Information ............................................................................ 22 US Regulatory Information This device complies with FCC Part 15C. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference which may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. : UWD-3100 DartWand Software User Guide 1.0 21 Regulatory Information Canada Regulatory Information Canada Regulatory Information This device complies with ICES-003, RS-220, and RSS-GEN for indoor use only. Operation is subject to the following two conditions: This device may not cause harmful interference this device must accept any interference which may cause undesired operation RF Notice Any changes or modifications to Zebra Enterprise Solutions (ZES) equipment not expressly approved by ZES could void the userâs authority to operate the equipment. EU Regulatory Information Model WND-3100 is approved for use in the following countries. AT BE BG CY CZ DK EE FI FR DE GR HU IE IT LV LT LU MT NL PL PT RO SK SI ES SE GB IS LI NO CH Important Notice: This RF device is intended for indoor and outdoor use in all EU and EFTA countries. 22 : UWD-3100 DartWand Software User Guide 1.0 9 Specifications Frequency Range: 6.35 â 6.75 GHz Antenna Gain: 9.5dBi USB Interface: USB 2.0 Environmental/Physical Operating Temperature: -40°C to 70°C (-40°F to 158°F) Environmental: IP54 Length: 5.26 in. Width: 3.24 in. Height: 1.57 in. Weight: 0.36 Lbs Power: 5V @ 0.25A : UWD-3100 DartWand Software User Guide 1.0 23 Appendix I: Estimated UWB Range Pr el im in ar The following figure shows the estimated DartWand UWB range based on the UWB Range setting. : UWD-3100 DartWand Software User Guide 1.0 25
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Create Date : 2010:07:28 14:04:22-07:00 Creator Tool : Acrobat PDFMaker 8.1 for Word Modify Date : 2010:08:05 14:00:11-07:00 Metadata Date : 2010:08:05 14:00:11-07:00 Producer : Acrobat Distiller 8.2.3 (Windows) Format : application/pdf Creator : Zebra Enterprise Solutions Title : UWD-3100 DartWand Software User Guide Subject : v1.0 Document ID : uuid:59455db4-8f1b-48a5-bebd-75ef3d3c9769 Instance ID : uuid:a73cbf9a-fbe4-4545-8ef7-2341b108559c Company : Author-it Software Corporation Ltd. Comments : Copyright © 1996-2007 Author-it Software Corporation Ltd., all rights reserved. Has XFA : No Page Count : 25 Page Layout : OneColumn Author : Zebra Enterprise Solutions Keywords : v1.0EXIF Metadata provided by EXIF.tools