Zephyrlock 2254 RFID System Locker Lock User Manual

Zephyrlock,LLC RFID System Locker Lock

Manual

Download: Zephyrlock 2254 RFID System Locker Lock User Manual
Mirror Download [FCC.gov]Zephyrlock 2254 RFID System Locker Lock User Manual
Document ID1154644
Application IDvAfYzVWoIdgQmxZfcZeK/w==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize10.61kB (132585 bits)
Date Submitted2009-08-17 00:00:00
Date Available2009-10-01 00:00:00
Creation Date2009-08-10 11:35:14
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2009-08-17 16:26:32
Document TitleMicrosoft Word - User Manual-.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: Owner

FCC ID: XLY-2254
ATTACHMENT E.
- User Manual -
HCT CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-RF09-0734
1/1
USER GUIDE
RF&KEYPAD INTEGRATED
LOCKER LOCK
(model :2254)
This manual is for the operation of locker lock by Keypad only.
For operation by RF key, please refer to our 2254 User Guide.
Version 1.0.0
-1-
Table of Contents
1. Understanding 2254 Locker Lock ........................................... 3
1.1 What is 2254 Locker Locks? .............................................................................. 3
1.2
Operation Card Types and Functions................................................................. 3
1.3 Locker Operation System ................................................................................... 4
2. Type of Lock Operation ........................................................... 5
2.1 Free Selection (Day Use)...................................................................................... 5
2.2 Fixed Mode (Pre-Assigned Mode) ....................................................................... 5
3. Operation of the Lock .............................................................. 6
3.1 Fixed Selection Mode ......................................................................................... 6
3.2 Free Selection Mode........................................................................................... 6
4. Lock Setting and Emergency open ....................................... 7
4.1 Lock Setting .......................................................................................................... 7
5. Indication Instruction................................................................ 8
Version 1.0.0
-2-
1. Understanding 2254 Locker Lock
1.1 What is 2254 Locker Locks?
2254 locker locks are the locker lock operated by either13,56 Mhz RF keys or
Digital keypads.
1.2 Operation Card Types and Functions
‹ Key Card
‹ Owner Card
Delete Master card registration in the lock
: Delete Master card registration in the lock
Register New Master card in the lock.
‹ Master Card
: Each of the following function can be set.
① Alarm Off
② Alarm Off, User card delete & registration, and
Locker open.
③ Alarm Off and Locker open.
‹ Set – up
Card
: ① Set the Time of the lock when battery is replaced.
② Master Card registrations
‹ User Card
: Two types of User Cards can be set by Locker
Management System.
① User card for Fixed Mode
② User Card for Free Selection
‹ Clear Card
: Delete the User information in the memory of the lock (Owner,
Master, and User)
Version 1.0.0
-3-
1.3 Locker Operation System
Locker Operation System (LOS) is consisted of PC based locker management
program and RF Card reader, and enable the operator to issue User card, check lock
status and to produce the statistical report.
System requirements
: Microsoft Windows XP
Serial port (or Serial to USB cable) for RF card reader
Interface
Version 1.0.0
-4-
2. Type of Lock Operation
2254/2255 locker locks are designed to work for the various operation requirements
by simple set up process. Following operation modes can be programmed before or
after lock installation.
2.1 Free Selection (Day Use)
- User can select any empty locker.
- LED lamp is blinked to represent locker is in use.
- Programmable to use multiple locks with
one User card.
- Programmable for Time based operation
2.2 Fixed Mode (Pre-Assigned Mode)
- Locker assigned to each User card in advance.
- Programmable to use multiple assigned lockers
with one card
(max. 5 lockers in current program).
- Programmable for multiple user mode
per a locker (max. 9 users in a locker).
Version 1.0.0
-5-
User
User
User
User
User
3. Operation of the Lock
3.1 Fixed Selection Mode
1)Default Pass Code :1234
2)Open: “ZEPHYR” button + “4 digit pass code”+ “ZEPHYR” button
3)Close: Automatic after several seconds
4)Change Pass Code: “ZEPHYR” button + old pass code + “ZEPHYR” button
+ new pass code + “ZEPHYR” button + new pass code + “ZEPHYR” button
Note: Passwords can be changed only when the lock is under unlocked
situation.
5) If user wants to the RF key instead of Digital key, the digital key stored in the
lock needs to be erased by Master Card (key), and new user RF key(card) can
be used.
This
3.2 Free Selection Mode
1)Close: “ZEPHYR” button + self-selected 4 digit code + “ZEPHYR” button
2)Open: “ZEPHYR” button + the same 4 digit code + “ZEPHYR” button.
Bolt stays open
Note: After it is unlocked, any 4 digit password can be used to lock it.
In any case, lock will automatically open after 8 hours, however this time can be
changed.
Version 1.0.0
-6-
4. Lock Setting and Emergency open
4.1 Lock Setting
1)
Press “Zephyr” button, and put the Key card and the programmed Set up
card to the front lock body in turn.
Note : If the lock was already set to any operation mode, and you intend
to change this operation mode, please erase any User information
stored in the memory of the lock by using Clear Card.
2)
The GREEN LED indicator will illuminate followed by melody.
3)
The lock will stay as it was (i.e, there is no latch movement). Lock will retain
code on both Free selection and Fixed Selection mode.
4.2 Emergency Open
1)
In case User forget his(her) password, Operator can open the lock by Master
Card.
2) Once Master card is used to open the lock, the lock reverts to default
position
(i.e. lock will stay open for Free Selection, and default code of 1234 for Fixed
Selection mode.).
Version 1.0.0
-7-
5. Indication Instruction
1)
All the pass code is 4 digit(0-9).
2)
“ZEPHYR” button: wake up button,the keypad or RFID does not respond
before you press “ZEPHYR” button.
3)
Open/Close:GREEN LED on for 0.2 second, one beep sound for 0.2 second.
4)
Successful programming:Melody.
5)
Indicate for mistake:RED LED flashes 3 times,
6)
Low voltage:RED LED blinks 5 times, and beep sounds 5 times.
7)
Incorrect pass code or input is beyond 5 digits: see #5, power off,need to
3 beep sounds
press “ZEPHYR” button to wake up the keypad.
8)
When the input is incomplete,after 5 seconds, see #5,power off .
You need to press “ZEPHYR” button again to wake up the keypad.
Version 1.0.0
-8-
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this
equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be
installed and operated with minimum 20 cm between the radiator and your body. This transmitter must not be collocated or operating
in conjunction with any other antenna or transmitter unless authorized to do so by the FCC.
IC Warning
Operation of this device is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2009:08:17 16:26:32-07:00
Create Date                     : 2009:08:10 11:35:14+09:00
Metadata Date                   : 2009:08:17 16:26:32-07:00
Format                          : application/pdf
Title                           : Microsoft Word - User Manual-.doc
Creator                         : Owner
Document ID                     : uuid:e755386c-7744-44b1-8a09-bff2319f1962
Instance ID                     : uuid:c32e5b52-1e2b-4398-8c97-5bd759dd639c
Has XFA                         : No
Page Count                      : 10
Author                          : Owner
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XLY-2254

Navigation menu