Ziehl Abegg SE AMMODBUSW RF Module AM-MODBUS(-W) User Manual
Ziehl-Abegg AG RF Module AM-MODBUS(-W) Users Manual
Contents
- 1. installation instruction
- 2. operating instruction
operating instruction
english AM-MODBUS / AM-MODBUS-W Part.-No. 349045 / 349050 Communication module for ECblue fans Operating Instructions L-BAL-E075-GB 1012 Index 002 Part.-No. 00163334-GB Operating Instructions AM-MODBUS / AM-MODBUS-W – model series Content General notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Structure of the operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 Operational area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3 Transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5 Waste disposal / recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1 Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 Connection of external terminal type A-G-247NW . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3 Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3.1 5.3.2 5.3.3 Networking via MODBUS-RTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS-485 - network design and interface parameter . . . . . . . . . . . . . . . . . . . . . . . . AM-MODBUS-W Wireless Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating by terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1 Hand held terminal type A-G-247NW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2 Establish connection to member . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.3 Menu operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.4 Menu structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 10 Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1 Menu overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 11 Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.1 Connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2 Manufacturer reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.3 Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 14 15 15 L-BAL-E075-GB 1012 Index 002 Part.-No. 00163334-GB 1/15 (for AM-MODBUS-W modules only) Note: The AM-MODBUS-W module is strictly limited for the integration and usage in host devices (fans and converters) of Ziehl-Abegg AG. When the AM-MODBUS-W module will be mounted in a fan or converter of Ziehl-Abegg AG, the FCC/IC label (AM-MODBUS-W inside) has to be stick on the housing of the converter Sticking the FCC/IC label (AM-MODBUS-W inside) on the housing of the fan. Operating Instructions AM-MODBUS / AM-MODBUS-W – model series 5.1 Electrical installation Electrical installation Safety precautions Danger owing to electric current • Work on electric components may only be carried out by trained electricians or by persons instructed in electricity under the supervision of an electrician in accordance with electrical engineering regulations. • It is forbidden to carry out work on electrically live parts. 5.2 Connection of external terminal type A-G-247NW If necessary an external terminal can be connected. This can be e.g. necessary to adapt the presetting during start-up. For information about the current operating condition a terminal can be permanent attached. A-G-247NW + 3,3 V IRDA-RXD IRDA-TXD IRDA-SD (D+) (D-) GND +5V AM-MODBUS GND (D+) (D-) ID GND (D+) (D-) ID fout GND 30.04.2009 v_modul_link_terminal.vsd The connection is made via a 4-strand line at the terminals (D-, D+ and GND). e.g., telephone ex e.g. J-Y (St) Y 2x2x0.6 (or similar), maximum line length ca. 250 m. • Signal “D+” and “D-” (RS 485) • The voltage supply of the terminal is made by the accumulators inserted there or the plug power supply unit. 5.3 5.3.1 Communication Networking via MODBUS-RTU The device comes equipped with a RS-485 interface for networking via a MODBUS. Connection to terminals “D+”, “D-”, “ID” and “GND”. The addressing takes place automatically over the terminals “ID”. Therefore a manual addressing of each member in a network is not necessary anymore. A maximum of 64 members can be directly connected to one another, and another 63 members via a repeater. L-BAL-E075-GB 1012 Index 002 Part.-No. 00163334-GB 5/15 Operating Instructions AM-MODBUS / AM-MODBUS-W – model series 5.3.2 Electrical installation RS-485 - network design and interface parameter You must ensure correct connection; i.e. "D+" must also be connected on the following devices to "D+". The same applies to "D-". At the rst fan (connected with the terminal for programming), the terminals “GND” and “ID” must be bridged. This guarantees that the software assigns to this fan the address 1. In addition, a "GND" connection must be established, as dissimilar potential (over 10 V!) will lead to the destruction of the RS-485 interface (e.g. lightning). A-G-247NW + 3,3 V IRDA-RXD IRDA-TXD IRDA-SD (D+) (D-) GND +5V AM-MODBUS AM-MODBUS GND (D+) (D-) ID (D+) GND 3...63 (D-) ID fout GND GND (D+) (D-) ID GND (D+) (D-) ID fout GND 30.04.2009 v_modbus_link_autoaddr.vsd Connection example for MODBUS device connection with automatic addressing The data line must be conducted from one device to the next. No other type of wiring is allowed. Always use only two wires of one lead (twisted pair) for the connection. Recommended wire types 1. CAT5 / CAT7 cables 2. J-Y (St) 2x2x0.6 (telephone wire) 3. AWG22 (2x2 twisted pair) When using telephone ex with four cable cores, we recommend the following allocation: “D+” = red “D-” = black “ID” = yellow “GND” = white Information • Pay attention to sufcient distance from powerlines and motor wires (min. 20 cm) • Do not use wire shield • Except the data link “D+”, “D-” the “ID” and the “GND” connection may no further cable cores of the data line be used. • Max. allowed wire length 1000 m (CAT5/7 500 m) Default interface parameter Baud rate Bits Patity Stop bits Handshake 19200 even non Information If any matters are unclear, please contact our V-STE support department for control systems ventilation technology. The information sheet "Network structure of Modbus" R-TIL08_01 contains detailed information about Modbus. L-BAL-E075-GB 1012 Index 002 Part.-No. 00163334-GB 6/15 Operating Instructions AM-MODBUS / AM-MODBUS-W – model series 5.3.3 Electrical installation AM-MODBUS-W Wireless Communication The type A-G-247NW hand-held terminal can communicate wireless with the type AM-MODBUS-W communications module. In a hard-wired system, wireless communication is primarily designed in order to have a second interface for communicating with the device (e.g., for conguration and diagnostics). In the A-G-247NW, for wireless communication with an EC fan type ECblue Basic use the |ECblue Basic (RF)| menu item. Wireless communication is also used by the MODBUS protocol, so it is necessary to assign an address. Wireless and hard-wired communications use the same address. The address can be hard-wire assigned via an RS-485. For pure, wireless communication, it is recommended to assign the address manually. • Switch on the device you want to re-address and establish a connection with address 247. • In “IO Setup”, change the address and then switch this device off again. • Apply the same procedure to the next device. Radio control key (0 - 9999) Different from RS-485 communication, wireless communication also has a radio control key (0 9999). This radio control key is used to encode the messages and ensures that several networks can be operated in mutually overlapping radio ranges. For that reason, every wireless MODBUS network should have its own radio control key if there is another wireless MODBUS network in the vicinity. The factory setting is |9999 | . A radio control key with the value |0 | switches off encoding. The ECblue must be switched off to save the new radio control key. The radio control key must be assigned in the same manner as the assignment of the MODBUS address. The radio control key can be found in the ECblue basic menu in the “Controller Setup” menu item. Technical data for wireless Communication: Radio communication standard: IEEE 802.15.4 Frequency: 2.4 GHz (not licensed wireless band, like WLAN, Bluethooth) 16 wireless channels, default wierless channel 0 Communications range: Short-distance radio, within buildings max. 8 m typically 3 - 5m, free eld to 25 m, generally strongly dependent on interferences Type of communication: Bi-directional, half dublex Application protocol: MODBUS-RTU (max. protocol length 125 Bytes and/or 50 register) Coding: Proprietary through 4-digit number Network structure: Point - to - point or point - to- mulit point - communication L-BAL-E075-GB 1012 Index 002 Part.-No. 00163334-GB 7/15 Operating Instructions AM-MODBUS / AM-MODBUS-W – model series 6.1 Operating by terminal Operating by terminal Hand held terminal type A-G-247NW Operating elements Ecblue-247 7 6 5 IXI 04.05.2009 v_bedien_erkl_a-g-247nw.vsd 1. 2. 3. 4. 5. 6. 7. 8. 9. Switch on terminal Program key and open menu Menu selection, increase value Menu selection, reduce value From each menu directly back to the display for “Speed” Escape = leave menu Select kind of member, set address, switch off program * Display Key not used* * Soft key, function depending on program Display description 2 3 4 5 6 7 8 9 10 11 12 13 04.05.2009 v_display_erkl_A-G-247NW.vsd L-BAL-E075-GB 1012 Index 002 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Numeric display 5 digit Moon-Symbol for set point 2 Current derating active Alarm-Symbol (fault indication) Brake motor or motor heating active Fire-Symbol (heating operation) temperature managment active (power reduction) External switch over direction of rotation active not used STOP-Symbol (enable) Bargraph Fanlevel Text line 3 gures (display unit, etc.) Text line 16 gures (display text menu.) Part.-No. 00163334-GB 8/15 Operating Instructions AM-MODBUS / AM-MODBUS-W – model series 6.2 Operating by terminal Establish connection to member The connection to the member is made by a connecting cable or wirelessly by means of radio. First select the kind of member with the keys ▼ + ▲ and conrm it with the P-key. Setting kind of member Main menu IXI ECblue Basic (RS485) ECblue fan with built in communication module type AM-MODBUS. Communication via cable. ECblue Basic (RF) ECblue fan with built in communication module type AM-MODBUS. Communication wireless. ECblue Premium (RS485) ECblue fan with built in Premium Module. Communication via cable. ECblue Premium (RF) ECblue fan with built in Premium Module. Communication wireless. ECblue Addressing Activation of the automatic addressing. ECblue Filetransfer File exchange via USB (PC ↔ Terminal). Conrm address Network Key IXI For communication wireless: Set network key an conrm withP-key. 9999 Device ID IXI The device address (Device-ID) of the members is factory set to the highest available MODBUS address: 247 Set address an conrm with P-key in order to make rst connection. 247 ECblue-247 IXI Successful connection. Controller Setup ECblue-246 Controller Setup IXI If no connection comes, settings cannot be stored. In the display the two symbols for alarm and antenna appear. Cause: wrong address, no connection via wire and/or radio. L-BAL-E075-GB 1012 Index 002 Part.-No. 00163334-GB 9/15 Operating Instructions AM-MODBUS / AM-MODBUS-W – model series 6.3 Operating by terminal Menu operation Switch over between menue “Speed” and “Start” (rst menue group) by key for Escape |Esc | . Speed Start Start By pushing the P- key one reaches the menu item “Start”. ↑ |ESC | ↓ Return to the menu group “Start” using key |Esc | . PIN input ▲▼ 6.4 One moves up and down within the menu group using the arrow keys. Menu structure ▼ ▲ Start ↑ |ESC | ↓ ▼ ▲ Info ↑ |ESC | ↓ ▼ ▲ Setting ↑ |ESC | ↓ Controller Setup ↑ |ESC | ↓ ▼ ▲ Motor Setup ↑ |ESC | ↓ PIN input Speed Set Intern1 Controlmode Rated Speed ▲▼ ▲▼ ▲▼ ▲▼ ▲▼ Reset Set Intern1 Set Intern2 Limit MotorRatedCurr. Selection of the menu group (e.g. Setting) to the right through the ▼-key, to the left through the ▼key. You can go to the menu items in the menu groups (e.g. Set Intern1) by using the P -key. Use the arrow keys to move up and down within the menu group. The menu groups consist of one area for the user (user menu) and one area for installation (service). The service area can be protected against unauthorized access by using a PIN. To make adjustments, press the P -key after selecting the menu item. If the previously set value starts to ash, it can be adjusted with the ▼ + ▲ keys and then saved with the P -key. To exit the menu without making any changes, use the “Esc” key, i.e., the originally set values remain. L-BAL-E075-GB 1012 Index 002 Part.-No. 00163334-GB 10/15 Operating Instructions AM-MODBUS / AM-MODBUS-W – model series 7.1 Programming Programming Menu overview Parameter Factory setting User Setting Start PIN input ----- Reset OFF ECblue Firmware Info Speed 0 rpm Motor current 0.0 A Output power 0.0 % Set Intern1 0 rpm Setting PIN 0010: Opening service menu (Controller Setup, IO Setup, Motorsetup), for programmed access level <2 PIN 1234: Opening user menu (Setting) for programmed access level <1 PIN 3698: Assumption of the communication parameters (Address, Com Baudrate, Com. Mode) PIN 9095: load factory setting (only parameters for current access level) 1800 rpm Setting in control mode |4 | active. By inputs “D1” and “E1” switch over to “Set Intern2” or “Set Intern3” possible. Display for active setting: Set Intern1 * Set Intern2 1800 rpm Setting in control mode |5 | active or in control mode |4 | , if activated by inputs “D1” or “E1”. Display for active setting: Set Intern2 * Set Intern3 1800 rpm Setting in control mode |6 | active or in control mode |4 | , if activated by inputs “D1” or “E1”. Display for active setting: Set Intern3 * Min. Speed 0 rpm Max. Speed 1800 rpm Set Intern1 Controller Setup Controlmode |0 | |0 | : Control by “E1” (0 - 10 V / PWM) |1 | : Bus control: control register2 (speed value) |2 | : Bus control: control register2 Fractional 0-32767 = 0 – 100% |3 | : Bus control: control register2 Fractional 0-100 = 0 – 100% |4 | : Constant speed “Set Intern1” with switch-over possibility to “Set Intern2” or “Set Intern3” |5 | : Constant speed “Set Intern2” |6 | : Constant speed “Set Intern3” Limit 75 % LED Mode |ON| Accesslevel |2 | Network Key 9999 L-BAL-E075-GB 1012 Index 002 Function only actively if function |3D | for “D1” or “E1” assigned. |ON | : Status LED in ECblue active (operating conditions are indicated by ash code). |OFF| : Status LED not active. |0 | : No setting without PIN (F PIN input). |1 | : “Setting” free, without PIN alterable, PIN 0010 for “Controller Setup”, “IO Setup”, “Motorsetup”. |2 | : All settings without PIN possible. Network key 0 - 9999 0 = no protection Part.-No. 00163334-GB 11/15 Operating Instructions AM-MODBUS / AM-MODBUS-W – model series Parameter Factory setting User Setting IO Setup D1 Function |1D | D1 Inverting |OFF| E1 Function |1E | E1 Inverting E1 Min. |OFF| E1 max. 100 % |2K | K1 Inverting |OFF| Watchdog Time 0 sec Watchdog Mode |OFF| : without function |1D | : Enable ON / OFF |3D | : Limit ON / OFF |5D | : Constant speed “Set Intern2” for controlmode |5| (priority when simul- taneous activation of “Set Intern3”). |6D | : Constant speed “Set Intern3”for controlmode |6 | |11D| : Setting max. Speed ON / OFF |13D| : Switch over direction of rotation |1E | 0 - 10 V external Setpoint works at settings higher |1E | as digital input ( |1D | ... |13D | FD1 function) Adjustment input signal and output characteristic with function |1E | 0% K1 Function Programming |1K | Operating indication |2K | Fault indication |4K | Limit (Speed > Set Intern3 at output power > 0%) |17K | Bus control MODBUS communication watchdog denes a behavior in case of a communication failure. If the device receives no message in a time window the device will execute the selected function (F Watchdog Mode). Functions executed when watchdog time outs: 0: no function (Default) 1: fault triggering 2: constant speed Set Intern1 |0 | 3: fault + Set Intern1 Bus Address Com. Baud rate Com. Mode Parameter Default interface parameter Changes become only effective after PIN input 3698 or interruption the line voltage for ECblue. 247 19200 8E1 Factory setting User Setting Motor Setup Rated Speed 1800 rpm * MotorRatedCurr. 2.5 A * Rampup time 10 sec * Rampdown time 10 sec * Rolling direct. Suppression1 OFF Range1 min. ----- Range1 max. ----- *These settings are shown for informational purposes and must only be changed after consultation with Ziehl-Abegg and entering a password. R* Suppression2 OFF Range2 min. ----- Range2 max. ----- Suppression3 OFF Range3 min. ----- Range3 max. ----- L-BAL-E075-GB 1012 Index 002 Part.-No. 00163334-GB 12/15 Operating Instructions AM-MODBUS / AM-MODBUS-W – model series OTM Diagnostic 00 IGBT temperature 23.6 °C Inside Temperature 23.6 °C MCU temperature 23.6 °C Motor temperature 23.6 °C E1 Input 0% DC Voltage 409 V Line voltage û 330 V Status messages Fault messages Accesslevel |2 | L-BAL-E075-GB 1012 Index 002 Part.-No. 00163334-GB 13/15 Programming Operating Instructions AM-MODBUS / AM-MODBUS-W – model series 8.1 Enclosure Enclosure Connection diagram AM-MODBUS GND (D+) (D-) ID GND (D+) (D-) ID fout GND n = f x 60 GND Data Data Addressing RS-485 GND Data Data Addressing RS-485 L-BAL-E075-GB 1012 Index 002 Part.-No. 00163334-GB 14/15 MOSI09K0 30.04.2009 Operating Instructions AM-MODBUS / AM-MODBUS-W – model series 8.2 Enclosure Manufacturer reference Our products are manufactured in accordance with the relevant international regulations. If you have any questions concerning the use of our products or plan special uses, please contact: Ziehl-Abegg AG Heinz-Ziehl-Straße 74653 Künzelsau Telephone: +49 (0) 7940 16-0 Telefax: +49 (0) 7940 16-504 info@ziehl-abegg.de http://www.ziehl-abegg.de 8.3 Service information If you have any technical questions while commissioning or regarding malfunctions, please contact our V-STE support department for control systems - ventilation technology. Our worldwide contacts are available in our subsidiaries for deliveries outside of Germany. F www.ziehl-abegg.com. If you make returns for inspections or repairs we need certain information in order to facilitate focused trouble shooting and fast repair. Please use our repair tickets for this. It is provided to you after you have consulted our support department. In addition, you can download it from our homepage. Download - Ventilation Technology - Topic: Control Engineering - Document type: General documents. L-BAL-E075-GB 1012 Index 002 Part.-No. 00163334-GB 15/15
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Author : Verwendete Zähler: Modify Date : 2012:08:24 09:06:47+02:00 Subject : Keywords : j:, Bookmark-Zähler, ("titel") Create Date : 2010:05:21 14:36:32+02:00 PXC Viewer Info : PDF-XChange Viewer;2.5.205.0;Aug 14 2012;17:23:22;D:20120824090647+02'00' Page Count : 16 XMP Toolkit : XMP Core 4.1.1 Creator Tool : WebX Systems - UltraXML Metadata Date : 2010:05:21 14:41:59+02:00 Format : application/pdf Title : a bis e: Kapitelzähler ("titel") Creator : Verwendete Zähler: Description : Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:2e124587-5217-47a6-9a0f-39f4d9133157 Instance ID : uuid:1dd12351-8b45-4499-b1b1-de528e5b9931EXIF Metadata provided by EXIF.tools