E Series® Data Comm
PRODUCT DESCRIPTION
Data Comm is an accessory card that plugs into the PCMCIA data card (rear most) slot on the E Series‘ defibrillator/monltor and provides case
data storage and upload services. Data is transmitted to remote data management systems, such as RescueNet’ ePCR, via the lEEE 802.11b/g
(WiFl) protocol. The Data Comm card is operational when the E Series is in a clinical operating mode and configured to record data to the
PCMCIA data and. Data storage and transmission stops when the CARD FULL message is displayed on the E Series screen.
GEI'I’ING STARTED
The Data Comm card provides storage oi aii E Series data currently written to the PCMCIA data card (based on unit configuration) with the
exception of audio data. data may be retrieved or erased manualiy by the user when the a Series system is in system Utilities Mode (see
Appendix B or the Series Operators Guide, P/N ease-1210431).
When the Data Comm card ls Installed’in the E Series, the following E Series Configuration options will automatimlly be set as shown below (see
the E Series Configuration Guide, P/N 9650410101):
REPORT MEMORV CARD ERRORS YES
CARD OlPACITV MESSAGE ENABLED YES
ERASE CARD PROMVT AT PWR OFF VES (if the ALLOW CARD ERASE option is set to YES)
REMOVE CARD PROMPT AT PWR OFF N0
Communication with the Data Comm card is established by the receiving data management system (such as Rescueuet ePCR). See the
appropriate receiving system documentation for instructions on establishing the connection between the
Data Comm card and the receiving system.
The Data Comm card ls compatible with E Series units with software version 7.42.000 or higher.
SYMBOLS USED
Attention, consult accompany documenu.
Follow operator instructions.
Manufacturer.
Catalogue Number
Serial Number
@E£®fi
(((-))) Nonlonixing electromagnetic radiaiion.
Return to a collection site intended for waste electrical and electronic equipment (WEEE). Do not dispose ofin unsorted trash.
fif-
WARNINGS
The Data Comm card is not a hot-swappable device. The E Series should be powered down and AC power removed prlor to removing
and/or inserting the card.
The Data Comm card will stop recording data when the CARD FULL message is displayed on the E Series
Up to 16MB of data may be stored In temporary memory before the CARD FULL message is displayed. Erasing the temporary memory is
recommended after each case in order to prevent Interruption of data storage and transmlssion during subsequent uses. Note: As a rule
of thumb, the E Series stores approximately 4ME of data for each liuur of operation (when audio recording is not activated) lf configured
to store all physiological data.
The Data Comm card will stop transmitting data to external systems when the CARD FULL message is displayed on the 5 Series.
0 Transmission of audio recordlng data, m a remote data management system, Is not supported.
9652-000975-01 Rev, A 01011 ZOLL Medlcal Corporation. All right reserved. 1
- Do not immerse the Data Comm card in liquids ’ ': \
- Do not subject the Data Comm card to extreme temperatures
- Do not use alcohol or ketones on the Data Comm card as these fluids may damage the device.
0 The Data Comm card uses one or more radio transmitters for communicating with remote data management systems, While this card has
demonstrated EMC compliance when used as designed with the E Series, there Is no guarantee that interference will not occur In a
particular Installation Transmissions from these radios may interfere with other electronic medical equipment used within the ambulance
Before using the Data Comm card for the first time, ensure that the performance of other patient care devices is not compromised by
Interference from Data Comm radio transmissions
- The card Is a non-seMceabIe/repairable item. Please contact ZOLL‘ Medical Corporation for assistance. (See the E Series Operator’s Guide
for current contact information)
leI'ALLA'HON
The existing rubber cover, PCMCIA data cards and modem cards must be removed (see figure 1 below). The Data Comm card is then Installed in
the rear most card slot on the E Series when facing the front of die device (see figure 2 below). The new rubber cover Is then fit down over the
top ol the Data Comm until it is firmly In place. Two screws, with washers, are used to secure the rubber cover to the top of the E Series.
ll 1r*—5CREWS
~—-——rlAslieas
ll V——-scliews
MMODEM BRACKET @ CWER
fl ‘ _ r Data Com
Figure 1 Figure 2
COMPLIANCE INFORMATION
The Data Comm card generates, uses, and can radiate radio frequency energy and, if not Installed and used in accordance with fliese
instructions, may cause harmful interference to radio communications, While this card has demonsuated EMC compliance when used as
dfiigned with the E Series, there is no guarantee that Interference will not occur in a particular installation. If this device does cause harmful
interference to radio reception, you are encouraged to relocate the E Series away from the radio,
This device has been teswd and found to oomply with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (1) this device must accept any interference received, Including interference that may cause
undesired operation iofiiie radio function).
This device has been tested and found to comply wiili ass no or Industry 3. Science Canada. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation (of the radio function).
ZOLL, E Series, and RescueNet are registered trademarks of ZOLL Medial Corporation.
9652-000975-01 Rev. A ©2011 ZDLL Medical Corporation. All rights reserved. 2

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : 
Create Date                     : 2011:05:12 10:46:52-04:00
Modify Date                     : 2011:09:15 08:52:35-04:00
Subject                         : Image
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : 
Description                     : Image
Title                           : 
Creator Tool                    : Canon iR5050
Metadata Date                   : 2011:09:15 08:52:35-04:00
Producer                        : Canon iR5050
Document ID                     : uuid:45edd8f5-a7cc-4ca4-951f-f1db58fddb8f
Instance ID                     : uuid:4a7645de-e435-4a0c-b7d9-917dd71bb0b1
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZKP-DMC001

Navigation menu