Zoll Medical RDC001 802.11 a/b/g/n embedded TCP/IP stack Wifi CF card with DFS User Manual UserManual

Zoll Medical Corp 802.11 a/b/g/n embedded TCP/IP stack Wifi CF card with DFS UserManual

User Manual

Download: Zoll Medical RDC001 802.11 a/b/g/n embedded TCP/IP stack Wifi CF card with DFS User Manual UserManual
Mirror Download [FCC.gov]Zoll Medical RDC001 802.11 a/b/g/n embedded TCP/IP stack Wifi CF card with DFS User Manual UserManual
Document ID1666081
Application ID8jR49WYZqHV7vWGO1h/rpw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize20.57kB (257095 bits)
Date Submitted2012-03-30 00:00:00
Date Available2012-08-01 00:00:00
Creation Date2012-03-23 17:25:08
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2012-03-23 17:26:09
Document TitleMicrosoft Word - UserManual
Document CreatorPScript5.dll Version 5.2.2
Document Author: KELLY

Z-RS-DC001 Manual
List
1. Introduction
1.1 Features
1.2 Specification
2. Installation Procedure
2.1 Open the device management
2.2 Install the driver
3. Application Software Installation and Data Transfer
3.1 Install RSeries WifiConfigure.exe
3.2 Data Transfer
1. Introduction:
Thanks for purchasing Zoll’s dual band 802.11 a/b/g/n embedded TCP/IP stack
Wifi CF card, R Series Data Comm. The Wifi CF card provides a Wifi interface only
to the CF interface of Zoll’s R Series Defibrillator. Because the CF card has a fully
self‐contained CF‐to‐Wifi functionality, it won’t use the processor bandwidth of
the Defibrillator to do data transfer.
1.1 Features:
1.30dBi/1.97dBi Embedded PCB printed Antenna @ 2.4GHz/5GHz
Compliant to 802.11 a/b/g/ and single stream 802.11n
2.4/5 GHz, 802.11n RF transceiver
Fully Self‐contained CF‐to‐wireless functionality – does not require any host
processor bandwidth
Support the data rate up to 65Mbps
Support WPA/WPA2‐PSK/WEP (64 and 128 bits) and TKIP mode of security in
infrastructure mode
Terminates TCP and UDP connections
Support Windows XP/7
Support CF Interface
1.2 Specification:
Standard: 802.11 a/b/g/n
Interface: CF Interface
Bandwidth: 2.412 ~ 2.462 GHz @ 2.4GHz band and 5.180 ~ 5.825GHz @ 5GHz
band
Modulation: OFDM with BPSK, QPSK, 16QAM, 64QAM, BPSK, QPSK, CCK
Data Rate: 65/58.5/52/39/26/19.5/13/6/5/54/48/36/24/12/9/6/11/5.5/2/1
Mbps
Security: WPA/WPA2‐PSK/WEP (64 and 128 bits) and TKIP mode
Antenna: 1.30dBi/1.97dBi Embedded PCB printed Antenna @ 2.4GHz/5GHz
OS: Windows XP and Windows 7
LDE Indicator: Power on/off
TX power: 9dBm @ 802.11a, 14dBm @ 802.11b, 11dBm @ 802.11g, 10dBm
@ 802.11n, 8dBm @ 802.11a/an
Sensitivity: ‐70dBm @ 802.11a, ‐75dBm @ 802.11b, ‐70dBm @ 802.11g,
‐69dBm @ 802.11n, ‐67 dBm @ 802.11an
Dimension: 60.5 x 41.7 x 6.45/5 mm
Temperature: 0 ‐ 55°C
Humidity: 20% ‐ 95%
Certification: FCC, IC
2. Installation Procedure
Note1: Please notify if the desktop or laptop PC include the PCMCIA interface or CF
interface.
Note2: Please notify if the CF card is installed in the desktop or laptop PC.
2.1 Open the device manager
a. Press right button and select “Management” to the Computer Management.
b. Select the device management to open it, which is showed as follows:
2.2 Install the driver
a. Press the left button on the PCMCIA interface to show all PCMICA devices.
b. Press the right button on the “Ambicom_Holdings –Inc
dual_Band_Wifi_CF_card” and select “Modify Driver”.
c. Please refer the figure 1 to figure 12 and follow the instruction of the Wizard to
complete the driver installation.
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11
Figure 12
Application Software and Data Transfer
3.1 Install RSeries WifiConfigure.exe
a. The PC has to be installed .Net 3.5 framework before run WifiConfigure.exe
b. Copy the WifiConfigure.exe in the CD to your PC.
3.2 Data Transfer
a. Please refer the figure 13 to fill the setting
b. Select DHCP or Static
c. If you select Static, you have to key in the IP address in “Local IP Address”
d. Check “Use DNS” and fill the IP address of DNS server to the “Primary
DNS” and “Secondary DNS”
e. In Wifi Radio of Wifi Setting, select “b/g/n (2.4GHz)” or “a/n (5GHz)
f. Enter a SSID you want to join in “Network Profile 1”.
g. Enter the Server IP and Server port in Defib History Transfer.
h. Enter the port number of the Upload Server
i. In network connection, select “Network Profile 1” to connect the upload
server via “Network Profile 1”.
j. If the connection is OK, the “File Transfer” will enable without any symbol.
k. Press the “File Transfer” to upload file.
Figure 13
Federal Communication Commission Interference Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to operate this
equipment.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Operations in the 5.15-5.25GHz band are restricted to indoor usage only.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated
with minimum distance 20cm between the radiator & your body.
This device is intended only for OEM integrators under the following conditions:
1) The antenna must be installed such that 20 cm is maintained between the
antenna and users, and
2) The transmitter module may not be co-located with any other transmitter
or antenna.
As long as 2 conditions above are met, further transmitter test will not be
required. However, the OEM integrator is still responsible for testing their
end-product for any additional compliance requirements required with this
module installed
IMPORTANT NOTE: In the event that these conditions can not be met (for
example certain laptop configurations or co-location with another transmitter),
then the FCC authorization is no longer considered valid and the FCC ID can
not be used on the final product. In these circumstances, the OEM integrator
will be responsible for re-evaluating the end product (including the transmitter)
and obtaining a separate FCC authorization.
End Product Labeling
This transmitter module is authorized only for use in device where the antenna
may be installed such that 20 cm may be maintained between the antenna and
users. The final end product must be labeled in a visible area with the following:
“Contains FCC ID: ZKP-RDC001. The grantee's FCC ID can be used only when
all FCC compliance requirements are met.
Manual Information To the End User
The OEM integrator has to be aware not to provide information to the end user
regarding how to install or remove this RF module in the user’s manual of the
end product which integrates this module.
The end user manual shall include all required regulatory information/warning as
show in this manual.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract
XMP Toolkit                     : 3.1-701
Format                          : application/pdf
Title                           : Microsoft Word - UserManual
Creator                         : KELLY
Create Date                     : 2012:03:23 17:25:08+08:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2012:03:23 17:26:09+08:00
Metadata Date                   : 2012:03:23 17:26:09+08:00
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Document ID                     : uuid:f58eed7b-bf5c-4b86-8e71-87dce561fd62
Instance ID                     : uuid:eef91380-22b3-45d0-aa54-3206d832894f
Page Count                      : 13
Author                          : KELLY
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZKP-RDC001

Navigation menu