Dear user!
This guide describes the actions performed during project setup.
If you still need more information, try the following:

•

Use other help files. You can open them using the program menu or by clicking “F1” or Start > Programs >
ABBYY FlexiCapture 10 Stations> Helps.

System Administrator’s Guide: Start > Programs > ABBYY FlexiCapture 10 Servers > Guides >
System Administrator’s Guide.
• Project Setup Guide: Start > Programs > ABBYY FlexiCapture 10 Stations > Guides > Project
Setup Guide.
• A Guide to Creating Machine-Readable Forms: Start > Programs > ABBYY FlexiCapture 10
Stations > Guides > A Guide to Creating Machine-Readable Forms.
• Help files for applications in FlexiLayout Studio 10 and FormDesigner 10 are opened from the
menu of the corresponding application or be pressing F1. You can also click Start > Programs >
ABBYY FlexiCapture 10 Stations > Helps.
For the standalone version, ABBYY FlexiCapture 10 Stations is replaced with ABBYY FlexiCapture
10 in the paths described above.

•

We hope you will enjoy using our product!

© 2011 ABBYY. All rights reserved.

2

Contents
1.

Introduction....................................................................................................................................... 4
1.1. The Purpose of Data Capture ..................................................................................................... 4
1.2. Data Capture Automation .......................................................................................................... 4
1.3. Documents You Can Process in ABBYY FlexiCapture 10......................................................... 5
1.4. ABBYY FlexiCapture 10 Stations ............................................................................................. 5
2. Creating a Project .............................................................................................................................. 5
3. Creating Document Definitions ......................................................................................................... 6
3.1. Creating a Layout ...................................................................................................................... 7
3.1.1.
Definition Objects’ Geometric Marking ............................................................................. 7
3.1.1.1.
Field groups ............................................................................................................... 8
3.1.1.2.
Fields with no marking ............................................................................................... 9
3.1.1.3.
Table marking ............................................................................................................ 9
3.1.1.4.
Fields with multiple regions ....................................................................................... 9
3.1.1.5.
Fields with multiple instances .................................................................................. 10
3.1.1.6.
Excluding a region from recognition ........................................................................ 10
3.1.1.7.
Deleting fields .......................................................................................................... 11
3.1.2.
Static Elements ................................................................................................................ 11
3.1.2.1.
Barcode Specifics ..................................................................................................... 11
3.1.3.
Field Properties ................................................................................................................ 12
3.1.3.1.
General Field Properties ........................................................................................... 12
3.1.3.2.
Data Type ................................................................................................................ 13
3.1.3.3.
Field recognition properties ...................................................................................... 18
3.1.3.4.
Verification settings ................................................................................................. 21
3.1.3.5.
Image Export Parameters ......................................................................................... 22
3.1.3.6.
Rules Check ............................................................................................................. 22
3.1.3.7.
Custom action/script editing ..................................................................................... 23
3.1.4.
Creating a Document Definition for Multi-Page Documents ............................................ 24
3.1.5.
Creating a Document Definition with Annex Pages.......................................................... 27
3.1.6.
Export Settings ................................................................................................................ 28
3.1.6.1.
Exporting to a file .................................................................................................... 28
3.1.6.2.
Exporting to a database ............................................................................................ 29
3.1.6.3.
Exporting to SharePoint ........................................................................................... 30
3.1.6.4.
Exporting images ..................................................................................................... 30
3.1.6.5.
Custom export (script).............................................................................................. 31
3.1.7.
Configuring Recognized Data Presentation ...................................................................... 31
3.1.8.
Testing Document Definitions ......................................................................................... 31
3.1.9.
Editing and Publishing a Document Definition ................................................................ 32
3.2. Creating a FlexiLayout ............................................................................................................ 32
3.2.1.
Classifiers ........................................................................................................................ 33
3.3. Specifics of Non-structured Documents ................................................................................... 33
4. Configuring Project Properties ........................................................................................................ 34
5. Configuring Batch Types ................................................................................................................ 35
5.1. General .................................................................................................................................... 35
5.2. Image Preprocessing ................................................................................................................ 36
5.3. Recognition ............................................................................................................................. 36
5.4. Event Handlers ........................................................................................................................ 36
5.5. Export ..................................................................................................................................... 36
© 2011 ABBYY. All rights reserved.

3

5.6. Workflow ................................................................................................................................ 37
5.6.1.
Standalone ....................................................................................................................... 37
5.6.2.
Distributed ....................................................................................................................... 37
5.7. .Net Assemblies ....................................................................................................................... 37
6. Configuring Image Import ............................................................................................................... 38
7. Uploading a Project to the Server .................................................................................................... 39
8. Keyboard Shortcuts ......................................................................................................................... 39
8.1. Main window .......................................................................................................................... 39
8.2. Document Definition Editor Window ...................................................................................... 41
8.3. Group Verification Window .................................................................................................... 43
8.4. Field Verification Window ...................................................................................................... 43

1. Introduction

1.1. The Purpose of Data Capture
A large variety of documents is used today: in business, production and services. Applications,
questionnaires, invoices, drafts and other documents are essential for any company. Modern information
technology makes paper documents insufficient, and most data is converted to electronic form for storage,
analysis and processing purposes.
The most labour- and time consuming thing about electronic documents was data input. It could only be
entered by hand, which was reasonable with a small amount of information. However, this doesn’t work
well with large document volumes. The speed of manual entry cannot be momentarily increased when the
situation so demands, because manual entry groups are hard to manage, and the costs of changes may
equal those of starting the process anew.
Thus, manual entry is not the optimal way. Its alternative, a simpler and more effective way, is an
automatic data capture system like ABBYY FlexiCapture 10.

1.2. Data Capture Automation
ABBYY FlexiCapture 10 is data capture software for processing structured, semi-structured (FlexiLayout)
and non-structured documents.
Automatic data capture consists of the following stages:
• A pack of pages is scanned using a document scanner first;
• The scanned pages are then automatically bundled into documents;
• The characters are automatically recognized;
• Uncertainly recognized characters are sent to the Operator for checking (verification);
• Confirmed data is finally exported to a file or database, and document images are saved to the
specified folder. Images can be saved in a graphical format or as a searchable PDF file.
ABBYY FlexiCapture 10 is an efficacious data capture automation solution allowing easy control over
work progress and quality.

© 2011 ABBYY. All rights reserved.

4

1.3. Documents You Can Process in ABBYY FlexiCapture 10
ABBYY FlexiCapture 10 is a data capture application supporting different document types.
The following document types can be processed in ABBYY FlexiCapture 10.
•

Structured documents. Documents with dedicated data fields that remain constant in quantity,
position and formatting throughout the document copies are called structured. These forms are
often issued in printed form for filling by hand. In order to identify a structured form and capture
the data, a layout must be created indicating field locations to the program. Layouts are created in
ABBYY FlexiCapture 10 during project setup.

•

Semi-structured documents. Documents with data fields that differ in quantity, position and
formatting from copy to copy are called semi-structured or flexible. Invoices are an example of this
type, because they are often different in the number of items and formatting, for they are issued by
different companies. All invoices include an account number and the amount of payment, but these
are located in different parts of the document. ABBYY FlexiCapture 10 uses FlexiLayouts for
identification of semi-structured documents and data capture. FlexiLayouts are created in ABBYY
FlexiLayout Studio. For information on ABBYY FlexiLayout Studio, see its Help File. Processing
of flexible or semi-structured documents is different from that of structured documents only at
creation and layout matching stages.

•

Non-structured documents. If you need to process non-structured documents with information
presented in free form, for example contracts, letters, orders, diagrams, ABBYY FlexiCapture 10
will also be a solution. Non-structured documents can be automatically identified as supplements to
structured or flexible documents, or by using FlexiLayouts, and then exported to image and
searchable PDF files. Index fields can be captured from non-structured documents automatically
(using FlexiLayouts) or manually. A typical non-structured document processing scenario would be
converting a paper archive to electronic form, with capture of a couple of index fields required for
attribute-based search.

1.4. ABBYY FlexiCapture 10 Stations
Depending on the installation type (standalone or distributed), the system will include different Stations. If
you are using the Standalone version, projects are set up at the Administrator Station. If you are using the
Distributed version, projects are set up at the Project Setup Station and then sent to the Application Server.

2. Creating a Project
A Project includes all the settings necessary for data capture (Document Definitions, Image Import
Profiles, Program Settings), and the documents to be processed.
Documents are merged into batches. The batch formatting type depends on the processing type. For
example, you can merge documents with the same creation date or from the set of documents scanned at
one go. Settings to be used during batch recognition are defined by the batch type. You can create several
batch types with the most commonly used processing settings. In this case, the Operator will only have to
select the necessary batch type. You can also specify the settings for the whole batch. These settings will
be applied to projects with the type set as “Default”. First, the project settings are specified, and then, on
their basis, batch types are formed (project settings are default settings for batch types).
© 2011 ABBYY. All rights reserved.

5

Work Batches are used for document processing. Test Batches are used during Document Definition
debugging. The difference between these batch types is that Test Batches make use of the local
(unpublished) Document Definition, while Work Batches use the published Document Definition. You can
access the list of Test Batches right from the Document Definition Editor window.
A Document consists of an image of one or several pages (i.e. single-page and multi-page documents) and
the data captured from them.
Multiple Document Definitions can be included in the project. In this case, documents of different types
will be processed within one project. Thus, you don’t need to presort the documents for processing. You
can combine different document types in one flow. However, if document flows don’t intersect, you can
create separated projects for them.
First, you need to create a project and at least one Document Definition.
To create a new project, either click New… in the Open Project dialog box that appears at program start,
or click File > New Project… on the main menu. Select a folder to save the project to and specify the
name.
To add batches to the project, use the New Batch command of the shortcut menu that appears when you
right-click the batch list. It is possible to load images without creating a batch. In this case, a batch will be
created by the program automatically.
To view the documents that were added to the batch, double left-click the batch name. To return to the
batch list, click Project > Work Batches or press Ctrl+B.

3. Creating Document Definitions
Creating Document Definitions is the main stage of project setup affecting the quality of resulting data
after document processing. To create a Document Definition, do the following:
• Create a layout (layout proper – in the Document Definition Editor or by loading a form built in
ABBYY FormDesigner, and FlexiLayout – by loading a file built in ABBYY FlexiLayout Studio
10);
• Set properties for each field and specify what data is to be found in each field (it increases
recognition quality considerably). Also, specify which fields are to be sent to the Operator for
Verification;
• Set Field Value Check rules. The rules help identify documents with values that don’t meet the
requirements, for example, the field value doesn’t correspond to the values from a particular
database.
• Set the data export method. Data can be exported to a file, a database, to Microsoftтм SharePoint or
according to the script procedure.
When the definition has been created, it must be published. It will then be available for document
processing.
The main actions of creating and editing the Document Definition are carried out in the Document
Definition Editor window that opens after a new definition has been created. To open the Document
Definition Editor, click Project > Document Definitions…, then select the definition name and click
Edit….
© 2011 ABBYY. All rights reserved.

6

To create a new definition, click Projects > Document Definitions... and, in the dialog box that opens,
click New…. The Document Definition Creation Wizard will open. In the Create New Document
Definition window, you can specify the main properties of the definition: the name, comment, language
and style. Then set the text type: select ICR (for hand-printed text) or OCR (for machine-printed text) from
the dropdown list. Later, it will be possible to change the text type for individual fields, and the type
selected at this stage will be used as default.
Next, you need to load or scan the image serving as a prototype for the Document Definition. (If your
document consists of multiple pages, load the first page for now. To learn how to add additional pages,
refer to the «Creating a Document Definition for Multi-Page Documents»). You can scan the page
(preferably not filled in) or load the image from a file. If you are going to process semi-structured
documents, use a FlexiLayout. Select Load FlexiLayout and enter the path to the FlexiLayout file with the
*.afl extension (the file that was created in ABBYY FlexiLayout Studio). If you were creating a flexible
Document Description, this will be the last step.
If you are creating a fixed Document Definition, the next step is as follows. Select field types to be
automatically found on the image. You can set checkmarks and text entry fields. The best results during
automatic search can be achieved if you use text fields with marking and rectangular checkmarks. If entry
fields have no marking, and the checkmarks are to be set against a white background, it is recommended
that you create them manually.
If your form has anchors (static elements of the given form, for example, squares used for identification
and/or matching of a Document Definition), they will be found and automatically marked on the image as
well.

3.1. Creating a Layout
3.1.1.

Definition Objects’ Geometric Marking

When all the steps of creating a Document Definition are complete, the loaded image will appear in the
Document Definition Editor window. The image will have fields of the types you selected at the last step
as well as anchors.
Automatic object selection can be carried out later by clicking
and clicking somewhere in the area of
the element you need to select. The element type and location will be identified automatically.
The Document Definition Editor has a set of easily accessible tools for field and static element marking:
•

Field Regions Mode (

) and

•

Static Element Mode (

).

To create a static element or field manually, you need to select one of these modes by clicking the
corresponding button on the toolbar, and then, clicking and holding the left mouse button, draw a rectangle
around the desired element. You can also hold Shift and left-click somewhere in the object area. In this
case the field or static element region will be defined automatically.
This is the list of tools for creation of different element types:
Fields:

Static Elements:
© 2011 ABBYY. All rights reserved.

7

- text entry field

- anchor

- checkmark

- separator

- checkmark group

- static text

- barcode

- barcode

- picture
- table
- group (of fields)
A barcodes can be either a recognizable field or a static element. Care must be taken when selecting the
mode that depends on the barcode purpose – if information is to be captured from the barcode, mark its
region in Field Regions Mode, and if it is used for definition identification and matching, mark it in Static
Element Mode.
Created fields appear in the list on the Fields tab of the Document Structure window. Names matching
the comments or the field names will be used by default. You can change the field name by selecting it in
the document structure and pressing F2. If you want the field to have the name matching the comments,
select the field, right-click it and, in the shortcut menu, click Get Name from Image…. Then, draw a
rectangle around the necessary text.
Field type can be identified by the icon in the list of fields and the frame color. Static elements are not
displayed in the list.
Objects can be copied (including to other document sections), deleted, and moved, and their size can be
changed. Names of field copies are numbered.
You can also select several objects at a time. To do it, hold Ctrl while selecting. The
used.

tool can also be

3.1.1.1. Field groups
Fields can be combined into groups to make document structure more illustrative or to created repeated
field groups. For example, the city, street and house number fields can be combined into the “Residence
Address”. Then, you can copy the “Residence Address” field group to create the “Work Address” fields.
To combine documents, use the

tool.

If there are repeated field groups in the documents, you can create several instances of the group you have
created. All field properties as well as rules set within the group will work for each instance of the group.
See 3.1.1.5 “Fields with multiple instances”.
You can also copy a field group, but, in this case, copying will result in creating a new independent group.

© 2011 ABBYY. All rights reserved.

8

3.1.1.2. Fields with no marking
There can be fields having no corresponding region on the image. Fields with no marking are marked with
a red asterisk in the list. Such fields can be used to store calculation results for values in recognized fields.
Fields with no marking have all the properties characteristic of their type: they can be sent to the Operator
for Verification, the format check can be executed, and the field values can be exported.
To create a field with no marking, do one of the following:
1. In the Document Definition Editor, click Edit > Create Field and create a field of the required
type. The field will appear in the list and will be marked with an asterisk. In this case, a
document structure field will be created, but not its region on the image.
2. Delete marking of a regular field. Select a field on the image or list and, on the shortcut menu,
click Delete Region. The marking will be deleted, and the field will be marked with a red
asterisk.
To create a region for fields with no marking, click
on the toolbar. If there are fields marked with an
asterisk in the list, the program will prompt you to select a name for one of such fields. This may happen
when you set the list of fields first and define their locations later.

3.1.1.3. Table marking
ABBYY FlexiCapture 10 gives you the possibility of working with tables. The Table fields are used for it.
A range of tools is available for table marking in regular Document Definitions. These tools are used to
draw tables, position lines and columns.
Draw a table region using the

tool. The table header must not be included in this region. Next, mark

the table cells using the
tool to add separators. To create vertical separators, point the cursor to the
table region, then drag the dotted separator to the desired place and left-click to fix it in its place.
Horizontal separators are created using the same method, only holding Alt. You can also initiate an
automatic separator search. To do it, select the table you have just created and use the following commands
of the shortcut menu: Autodetect Vertical Separators and Autodetect Horizontal Separators. To delete
a separator, click

. When you have added the required number of separators, set the columns by

clicking
and clicking in the column region. Each column contains cells of one type: text, checkmarks,
graphic elements or barcodes. The program will prompt you to select the column type when you set it.
When the geometric marking is finished, you will need to set the recognition and verification properties as
well as the data type for each column. Column properties are set exactly like the properties of regular
document fields.

3.1.1.4. Fields with multiple regions
If there are fields with regions consisting of several parts on your form, for example, tables stretching
across multiple pages, you can create fields with multiple regions for processing of such data.
Values from all regions of a field are merged and exported as one field. The line break serves as a
separator here.
© 2011 ABBYY. All rights reserved.

9

To create a field with multiple regions, create one of the field regions, select it, then right-click it, and, on
the shortcut menu, click Continue Region… Then, select a place for the region to continue at. Repeat the
procedure the required number of times.

3.1.1.5. Fields with multiple instances
Your document can include repeated objects – fields or field groups that are present in several instances
and that describe similar objects, for example, the same information about employees or their children, or
invoices. Fields with multiple instances are created for such objects.
Any field, except for a table, can have multiple instances, with their regions located far from each other,
possibly on different pages. Field instances have the same properties, and fields with multiple instances are
exported to separate database files or tables.
Fields with multiple instances can be useful when creating repeated field groups: you create a field group,
and then the necessary number of instances is created.
To create a field with instances, create one instance first, them select it, right-click the field region and, on
the shortcut menu, click New Instance…. Create the necessary number of region instances and move their
images to the required location on the page.

Figure 1. Using fields with multiple instances

3.1.1.6. Excluding a region from recognition
You may need to exclude a region from recognition in certain cases, for example, a region with comments
that hinders data capture of a field (Figure 2). To exclude a region from recognition, click
region to exclude with your mouse.
© 2011 ABBYY. All rights reserved.

and draw a

10

Figure 2. Excluding an unrecognizable region

3.1.1.7. Deleting fields
To delete a field, select it and press Delete or click Delete on the shortcut menu. To delete marking only,
leaving the field in the document structure, press Shift+Delete or click Delete Region on the shortcut
menu of the field.

3.1.2.

Static Elements

Static elements are objects that do not provide information for capture. They are used for Document
Definition matching and identification. Anchors are a type of static elements.
To begin working with static elements, switch to the special mode by clicking
static element marking.

, which will display

All static element types can be used to match a Document Definition, but the best results can be achieved
only if the documents have standard anchors – black squares, crosses or angles. They must be set manually
or automatically as a static element of the Anchor type. Their shape must be specified in the Element
Properties window, the General tab.
Static elements of any type can be used as identifiers as well. Analyzing the position and value of the
identifiers, the program finds the document the current page belongs to. If a barcode is used as the
identifier, you can specify its value manually – this helps identify the page quickly and precisely.
To use a static element for Document Definition matching and/or identification, select the corresponding
option in the General tab of the Properties dialog box. To open the Properties dialog box for any element,
click Properties... on the shortcut menu.
Static elements can be used when matching a Document Definition (select Use to match Document
Definition) and/or for Document definition identification (select Use to identify Document Definition).
Anchor: set the anchor type (square, cross, angle or rectangle). For standard anchors, select Use to match
Document Definition. Select Use to identify Document Definition only if the anchor locations are
unique for the current document section.
Static text: if the static text will be used for identification, you can enter the text value. You need to enter
the text value only if the page can’t be identified by its location alone (for example, if the pages are
different only in heading texts, while the location and size of these headings are the same).
Separator: choose to use the separator for document definition identification or matching.
Barcode: if the barcode will be used as an identifier, you can enter the barcode value. On the Recognition
tab, specify the barcode type, its orientation and image processing options.

3.1.2.1.

Barcode Specifics

If a barcode is used as an identifier, it is an anchor barcode and it belongs to static elements. Create it when
you are working with static elements. The Properties dialog box of such barcode has two tabs: General
and Recognition.
© 2011 ABBYY. All rights reserved.

11

If a barcode is used for data capture, it is a field. Create it when you are working with fields. The
Properties dialog box of such barcode has all the tabs of the Field Properties dialog box: General, Data
Type, Recognition, Verification, and Rules. The value of such barcode will be recognized and, if the
settings provide for it, sent to verification and export.

3.1.3.

Field Properties

It is important to set field properties correctly, because they affect the quality of field recognition and
define whether the field values are to be exported and sent to the Operator for verification. Some properties
are important for data recognition. For example, the text field marking property is to be set carefully, so
that the marking that doesn’t disappear during scanning is separated from the characters. It will lead to the
recognition resulting in text only, without unnecessary elements.
Correct field properties lead to better recognition results making the Operators’ work easier. When you set
field properties, document verification can be reduced to minimum.
When you have created a field of a certain type, it will have default properties. Some properties are taken
from the Document Definition (for example, language), others are defined automatically (for example,
marking type). They can be changed in the dialog box that opens when you click Properties on the
shortcut menu of any object. Every field type has its own properties.

3.1.3.1. General Field Properties
The Properties dialog box of every field has the General (Figure 3) tab. The Name and description are
specified on this tab. You can change the name automatically given to the field at the creation stage which
corresponds to the comments that are most close to the field. Caption is the field name as displayed as
data. The field type is displayed on this tab as an icon to the right of the name.
Additionally, the following options can be selected on the General tab:
• Export Field Value – clear this option if you don’t need to export the field value. This may be
necessary, for example, if the field value is used to get the value of the calculated field (see Rules
Checking), and you need to export the final result only.
• Read only – select this option to prohibit any changes by an Operator. You may want do select the
option for fields with values to be calculated automatically (according to rules), for example, for
fields where you plan to save a sum or combination of values of other fields (see Rules Checking).
• Show in data form – clear this option if you don’t want the field to appear on the data form when
viewing documents. If an error occurs in such field, you will be unable to correct it in the
Document Editor window, because the field will not be displayed. Thus, it is recommended to
specify the settings that will not cause any errors in such fields.
• Cannot be blank – select this option if the field is required to be filled in. If the field is empty, a
format error will occur.
• Index field – select this option if you are going to index the field. In this case, the field value will
appear for each document in the list, and the Operator will be able to sort and search for documents
by the value of this field. The index field value can also be used for file naming during export.

© 2011 ABBYY. All rights reserved.

12

Figure 3. The Field Properties dialog box, General tab

3.1.3.2. Data Type
Data Type defines the set of possible field values and the allowed field format. If the value entered in the
field doesn’t correspond to the specified data type, the operator will receive a verification error message.
The text data type usually has a simple area of valid values: the date, time, address, taxpayer’s account
number (INN), and sum. As for the checkmarks, the data type means values the field assumes when the
checkbox is selected or cleared.

3.1.3.2.1.

Data types of the text entry field

It is important to set the data type of the text entry field correctly. This tells the program what data type is
to be found in the field – figures, certain letters, specific characters, date or other. The program allows the
user to flexibly set data types. The user gets a ready set of data types which includes the types used most
often. Besides, the user will be able to create his/her own data types to suit the task at hand.
When you set data types, you can configure the system to check the format of input value as well as set
value restrictions, such as maximum and minimum numbers, time period for the date, and maximum
number of characters for text fields.
The data type is set on the Data Type tab of the Field Properties dialog box (Figure 4).

© 2011 ABBYY. All rights reserved.

13

Select a category from the Content list. In the Details field, the description of one of the data types
(chosen by default, or specified manually earlier) that belong to the category will be displayed.
If the Process value as text option is selected, the values of fields with any content will be processed and
exported as text. The field format check will not be carried out either.
To change the recognition Language or specify a more restricted data type, click the Edit… button
located to the right of the description.
For standard (or general) types (General is selected in Content settings list), you can do the following:
•

For Text – select several recognition languages (the “…” button). You can use the built-in
dictionary and/or custom dictionary. Information in the dictionaries will be taken into
consideration during field recognition then.

•

For Number – select Integer if the value is expected to be an integer number;

•

For Date – select the date component order, choose (not) to show months in words, choose (not)
to show time and day of week;

•

For Address, Name, Code – use a custom dictionary.

Special types (select Special in the Content settings list) contain predefined data types you can choose the
most suitable from. Mind the description on the bottom of the dialog box when making a selection.
You can create your own data type if none in the list suits your needs.
1. To create a new data type, select one of the values in the Contents list on the Data Type tab. You
can select any value in list that would correspond to the purpose of your type. The resulting data
type will be stored in the selected category, although the category itself doesn’t influence the new
type.
2. Click the Edit… button located to the right of the Details field. In the dialog box that opens, select
Special in the Content settings list. Click New….
3. Follow the New Data Type Wizard’s instructions.

© 2011 ABBYY. All rights reserved.

14

Figure 4. Field Properties dialog box, Data Type tab (text entry field)

Automatic processing of the recognized value can be carried out for any data type. Unnecessary spaces
will be deleted, capitalization and spelling corrected. To start automatic processing, click the Edit…
button located to the right of the Replace characters field. In the dialog box that opens, specify the
necessary text processing parameters (Figure 5).

Figure 5. The Autoreplace Settings dialog box

You can also configure the program to check the recognized field value for compliance of the value with
the set conditions (in this case, for date the program will check if the value is within the specified time
© 2011 ABBYY. All rights reserved.

15

period, for text fields, if the value is valid and if it has the required format, etc.). To specify value
restrictions for a field, click the Edit… button located to the right of the Value Check field. (Figure 6).

Figure 6. Value Check Settings dialog box

3.1.3.2.2.

Data types for checkmarks

For checkmarks, you can specify the values assigned to fields at checkmark selection/clearance. It is done
on the Data Type tab (Figure 7).
The following values can be assigned to checkmark fields:
 Yes – if the checkbox is selected, No – if the checkbox is clear;
 1 – if the checkbox is selected, 0 – if the checkbox is clear;
 Checkmark name – if the checkbox is selected, Empty line – if the checkbox is clear;
 User-created values can also be entered by selecting the corresponding option.
Note. If the checkmarks are grouped, they share the same properties which are created for the whole group.
Checkmark values are created in the group properties as well.

© 2011 ABBYY. All rights reserved.

16

Figure 7. Field Properties dialog box, Data Type tab
(checkmark not in the group)

3.1.3.2.3.

Data types for checkmark groups

In the Checkmark Group Properties dialog box, on the Data Type tab, the list of names of checkmarks in
the group will be displayed (Figure 8).
Clear the Allow empty selection option if you want at least one checkmark to be in the group.
If it is possible to select multiple checkmarks in the group, select Allow multiple selection.
You can define the exported values in case no checkmark is selected, or if more than one checkmark is
selected. Select either  or  and click Edit…. In the dialog box that
opens, enter a value in the Exported value field. If the export value is not set, an empty line will be
exported in case no checkmark is selected. In case multiple checkmarks are selected, the values will be
exported separated by commas.
If the Treat validation error as warning option is selected, a warning will be issued instead of an error
message.

© 2011 ABBYY. All rights reserved.

17

Figure 8. Field Properties dialog box, Data Type tab (checkmark groups)

3.1.3.3.

Field recognition properties

ABBYY FlexiCapture 10 allows specifying recognition settings for each field. Field properties defined
correctly on the Recognition tab of the Field Properties dialog box will increase recognition quality and
minimize the possibility of error. The properties differ for various field types. The recognition properties
by field are as follows.

3.1.3.3.1.

Text entry field recognition properties

Select the Don’t recognize (Key from Image field – will be entered manually) option if you don’t want
the field to be recognized, and if the value will be entered manually by an Operator. This may be
necessary, for example, if the field value is unrecognizable due to small intercharacter spacing. In this
case, you don’t need to specify other recognition properties, because this kind of field will not be
recognized. The Operator will be prompted to enter the field value during the field value check.
Now select the text type: ICR (for handprinted text) or OCR (for printed text). If you selected OCR,
choose the printing type from the dropdown list (typographic printer, matrix printer, typewriter, etc.). To
set multiple text types or use a template, select Advanced and click Modify…
Select Marking type from the dropdown list of examples. If the marking disappears during scanning, it is
recommended to choose the type suitable for fixed-pitch text (Gray rectangles). If the marking doesn’t
disappear and is split into character cells, specify the character cell number (it can be defined
© 2011 ABBYY. All rights reserved.

18

automatically). The Simple type is used for fields with no marking, usually for texts printed on typographic
printers.
You can select the Letter case for letters of a particular case to be found. If the field can be filled with
both small and capital letters, choose Auto.
Select either the horizontal or vertical text Orientation.
For a one-line field, select One line. For a field that will always contain one word (i.e. without spaces),
select One word.
Specify the image preprocessing properties. For example, the image can be despeckled with adjustable size
of “garbage” to be deleted. You can also invert the image or remove the texture.
Note. If the Despeckle image option is selected, the size of “rubbish” is defined automatically by default.
To set your own size, select Clear the garbage of specified size only and specify the size.

Figure 9. Field Properties dialog box, Recognition tab (text entry field)

3.1.3.3.2.

Checkmark and checkmark group recognition properties

For the checkmarks to be recognized correctly, specify the Checkmark type by using the dropdown list. If
the checkmark is in a square, select Square; if the checkmark is set against a white background without
any frame (or if the frame disappears during scanning), select Without frame. Select Auto for the
program to define the checkmark type automatically. In this case, the checkmark must be empty, because
the program will define whether there’s a checkmark by comparing the image of this area in the processed
document with that in the form the Document Definition is based on.
© 2011 ABBYY. All rights reserved.

19

You can allow corrections for certain checkmarks – if a checkmark was put incorrectly, the person who did
it can shade the whole checkmark. Completely shaded checkmarks will be deemed void. However, if you
selected the Auto type, you won’t be able to allow corrections.
Image preprocessing can be configured for checkmarks just like for text fields.
If checkmarks are grouped, they will share the same properties. Recognition properties are defined
likewise, but for the whole checkmark group.

Figure 10. Field Properties dialog box, Recognition tab (checkmark field)

3.1.3.3.3.

Barcode recognition properties

The properties of a barcode that is a field are the same as those of a Static Element barcode. In case of a
field barcode, the barcode type, orientation and image despeckle settings are specified. The only difference
is that the field value can be entered by the Operator. To allow this, select Don’t recognize (Key from
Image field – will be entered manually.

3.1.3.3.4.

Image recognition properties

On the Recognition tab of the Image Field Properties window, select Exclude from recognition if the
image area is to be excluded from recognition. This option is only available for the Image field type and is
used for compatibility with FormReader 6.5 templates).

© 2011 ABBYY. All rights reserved.

20

3.1.3.4.

Verification settings

Verification is checking recognized data by an operator. During Document Definition creation, you can
configure the verification settings on the Verification tab of the Field Properties dialog box (Figure 11).
Uncertainly recognized characters will be highlighted by the program and sent to an Operator for checking.
However, it is also possible to configure verification in such a way, that the field will be sent to an
Operator even if there are no uncertain characters, or vice versa, won’t be sent for checking even if there
are uncertainly recognized characters. Choose all (required verification) if you want to be absolutely sure
there is no error in the field value.
Character inclusion in group and field verification can be enabled by selecting the corresponding option(s).
Group verification applies to checkmarks and digits most. Other characters can also be verified in group
verification, if the corresponding option is selected for the field. Checkmark groups can be also sent to
field verification. You can select whether to send field to field verification always or only if it has
highlighted characters or format errors.
You can also use double verification mode where field is verified by two different operators. If merged
verification results match the document is sent to the next stage. Otherwise additional check is carried out.

Figure 11. Field Properties dialog box, Verification tab

© 2011 ABBYY. All rights reserved.

21

3.1.3.5.

Image Export Parameters

In the Image Field Properties, you can specify export parameters, such as the exported file type, quality,
color type and resolution. To do it, go to the Export tab of the Field Properties dialog box (on the field’s
shortcut menu, click Properties…). You can configure the following:
•
•
•

File type (TIFF, JPEG, BMP, JPEG2000, PCX packbits, PNG).
Quality. For TIFF, JPEG and JPEG2000 files, you can choose the exported file quality (best, high,
normal, low).
Color type – color, grayscale, halftone (b&w).

To specify the resolution of the exported image, select Change resolution to and enter your resolution or
select a predefined resolution from the list.

3.1.3.6.

Rules Check

Rules are needed to automatically check recognized data. The rules, along with data types, allow imposing
data restrictions, i.e. defining the conditions the field values must meet. If not, pages with such fields will
be flagged and marked with the corresponding message. Rules are mainly used for Document Integrity
Checks. Rules can also be used to process recognized data – combine several field values or replace
recognized values with values from the database.
Rules Check is a low priority task coming after automatic value correction, checking data for field format
compliance, and data validation (checking if the date falls within the specified period, the numbers, within
the specified interval, etc.).
ABBYY FlexiCapture 10 allows specifying the following Rules:
• Check Sum – checks the sum of several field values. The sum is then compared to the specified
number or value of another field. For example, if your document describes an employee’s salary an
bonus, with an overall income field, you can set a rule that will check if the salary and bonus sum
matches the overall expenditure. A warning message will be issued.
• Compare Fields – compares several field values (including those from different sections). This rule
can be used if your document has several fields with values that must be equal. If the values are not
equal, the Rules Check error will be issued.
• Database Check – entered values are checked by being compared to the values from a certain.
• Merge Fields – merging of several field values. Field values can be separated by dots, spaces or
other separators. For example, it may be more convenient to compile a date from already
recognized fields (Day, Month, Year), separating them with dots, than to recognize it as a whole.
The merging results can be stored in any field of the Document Definition. It is convenient to use
fields with no marking for this purpose (see Fields with no marking).
• Sum in Figures – Sum in Words (Russian) – compares a numerical sum with the same sum written
in words (Russian language only).
• Script – the user describes constraints with the help of a script. The script language is described in
the application help file in detail. As the order of rules to be checked is not specified, a field cannot
© 2011 ABBYY. All rights reserved.

22

be available from two Script rules at a time. It will be available from any number of rules only in
read-only mode.
Rules are specified on the Rules tab of the Field Properties dialog box (Figure 12). The rules can affect the
values of one or multiple fields.
Rule severity can be specified (choose either error or warning). The rule will be flagged red if an error
occurs, and yellow, if a warning is issued.

Figure 12. Field Properties dialog box, Rules tab

3.1.3.7.

Custom action/script editing

It is possible to create a custom script. As opposed to the script action triggered automatically, the userdefined custom action is triggered by the user during field verification or when viewing the document in
the Document Editor. The script is triggered by pressing the … button located to the right of the field
value. The script language is described in the help file of the application.
Custom action is configured on the Custom Action tab (Figure 13). To add or delete fields available in the
custom script, use the Add… and Delete buttons respectively. To open the Script Editor, click Edit…. To
enable the custom action/script, select Enable Custom Action.

© 2011 ABBYY. All rights reserved.

23

Figure 13. Field Properties dialog box, Custom Action tab

3.1.4.

Creating a Document Definition for Multi-Page Documents

ABBYY FlexiCapture 10 allows creating multi-page Document Definition. A definition can consist of a
random number of sections, each of them containing one or multiple pages. Section order, quantity and the
document assembly rules are specified for multi-page Document Definitions.
Document Definition Creation Wizard’s work will result in a simple Document Definition (without
sections) appearing. You can add pages manually. When a page is added, its image will appear in the
image area in the Document Definition Editor window. Fields created on this page will be added to the
general list of fields. In this case, the document will consist of one section with several pages.
You may want to add several pages to one section if the document contains blocks stretching over multiple
pages, repeating blocks or tables that occupy more than one page. The same method is used when loading
a multi-page FlexiLayout (see Creating a FlexiLayout). All fields of the FlexiLayout will have to belong to
the same Document Definition.
You can also add sections to a Document Definition. In the simplest case, one section contains one page.
This may be useful if field sets on the pages are independent. This method is rather transparent: you can
easily see the section the fields belong to, and set your own document assembly structure. For example,
your document has 3 pages, with the 1st and 3rd page occurring once, and the 2nd, 2-5 times. You will have
© 2011 ABBYY. All rights reserved.

24

to create a separate section for each page, and then set the document structure, i.e. section order and
number of repetitions.
A more complex case is a definition containing several sections that include more than one page each. For
example, it can be a Document Definition consisting of non-flexible section and a multi-page flexible
section, or a Document Definition describing documents consisting of a double-faced page that can repeat
a certain number of times. Assume you have to create a Document Definition with a title page (page A)
and a number of double-faced pages (page order B,C,B,C…). In this case, create the A section containing
one A page and the BC sections containing two pages: B and C. The document structure should be as
follows. The A section has one repetition followed by the BC section that repeats 3-7 times. Pages can also
be repeated within a section. Multiple repetitions should be used wisely so as not to cause misassembly of
the documents.
For Document Definitions consisting of several sections, key fields check can be enabled, in addition to
order and the number of repetitions. In each document section, you will have to define the key fields with
matching values in different sections. For example, you can take the name of a person who fills in the
document, and make it a key field. In this case, the name must be written on every page. You can also use
an identification number of some sort.
During batch processing, the program will attempt to assemble successive pages into documents while
checking assembly rules. Key field values will also be verified. A warning message will appear if key field
values don’t match on pages of one and the same document. It may sometimes happen when document
pages get mixed up during scanning. In this case, you need to change page order, for the document
assembly rules to be met.
To add a page to a section, on the Document Definition Editor menu, click Document Definition > Add
Page… or click Add Page… on the shortcut menu of the image. Load the image of an empty page and
select object types to be marked on the page automatically.
To add a new section, on the Document Definition Editor menu, click Document Definition > Add
Document Section…. The Create New Section Layout window will open, in which you will specify all
the necessary parameters. Follow the on-screen instructions and:
• Specify the section name;
• Load an image of an empty page (scan or load from file);
• Load a FlexiLayout, if necessary;
• Select the types of objects to be marked automatically.
The new section and its fields will appear in the Document Structure window.
To view the resulting document structure when creating a Document Definition, click the Pages tab in the
in the Document structure window on the right side of the Document Definition Editor window. The
document structure will be presented with page thumbnails. On this tab, you can change the number of
sections in the document. To do it, enter a new value (number or range) in the square to the right of the
section name. You can also add annex pages, change page order in sections, and move pages from one
section to another using the drag-and-drop method.

© 2011 ABBYY. All rights reserved.

25

Figure 14. Document structure, Thumbnails view mode

You can also specify the order and number of section repetitions by clicking Document
Definition > Document Definition Properties… in the Document Definition Editor window.
On the Assembly tab (Figure 15), specify the minimum and maximum number of section repetitions in the
document (the default number is 1).
If you want to check the key field values, select Check equality of key fields and then select a key field
for each section. Selection is made by double left-clicking.
In some cases, it may be necessary to disable the sections’ order check, for example, if it is not critical for
document assembly. To do it, select Disable sections order check. The presence of all sections in the
document will be checked anyway, and the sections’ order, will not.

© 2011 ABBYY. All rights reserved.

26

Figure 15. Document Definition properties, Assembly tab

3.1.5.

Creating a Document Definition with Annex Pages

ABBYY FlexiCapture 10 allows creating Document Definitions for documents with annexes.
Annex pages can accompany any document. Separate fields are not required to be searched on these pages,
so you don’t need to match Document Definitions for them. However, they are taken into account during
document assembly. For example, a credit application form (structured document) can be accompanied
with a reference letter written in free form. This reference can be processed as an annex page.
To create a Document Definition with an annex page? Do the following:
• In the Document Structure window on the right side of the Document Definition Editor window,
click the Pages tab and select Enable annex pages in documents. Enter the number (or range) of
annex pages in the square that appears to the right of the section name (Figure 14), or
• In the Document Definition Editor window, click Document Definition > Document Definition
Properties… and open the Assembly tab. Select Enable annex pages. Then, specify the minimum
and maximum number of annex pages (Figure 15).
To save the image of an annex page, enable image saving. To do it, in the Export Settings window, click
Edit and, in the dialog box that opens, click Save document images. Click Image Format Options to
save the image to a graphical format or a searchable PDF.

© 2011 ABBYY. All rights reserved.

27

3.1.6.

Export Settings

To configure saving of data obtained during document processing, you need to configure export for each
Document Definition. There are four export types: to a file of the specified format, to an ODBCcompatible database, to a MS SharePoint library, and custom export (using a script). Export is configured
in the Export Settings dialog box (Document Definition > Export Settings). To add a new export
destination, click Add…. To edit an existing export destination, click Edit…
Aside from settings in the Document Definition, export can be configured at batch and project levels.
Export configured at batch level is used for default batches. These settings will be used by default, when
an Operator starts the export by clicking File>Export To.
New export destinations are added using the Export Destination Wizard. First, you will have to specify the
general settings (the type and acceptance requirements), and then, the settings of the selected type.
You can specify several export destinations for one document definition. An export destination may be or
not be critical. If an error occurs when exporting to a critical destination, the process terminates. If an error
occurs when exporting to a non-critical destination, the process continues, and the document will be
exported. It is thus recommended to have at least one critical export destination, or export errors will
remain unnoticed. You can make an export destination critical in the Export Settings window.
Page images can also be exported – together with data or as a separate export procedure. You can specify
the sensitive information to be redacted for each export destination. To export images together with data,
select Export to image files in the Type dropdown box on the first page of the Export Destination Wizard
dialog box.
Note. If you are using a distributed version, you must specify file paths in UNC format
(\\server_name\share_name[\path]) in the uploaded project for the export to complete correctly. If
relative paths are specified, the export results will only be available using the application interface
(API). If absolute paths are specified in the :\[path] format, the export will terminate with an
error.
If you have specified relative export paths, you can specify the root path in UNC format when
uploading the project to the server. In this case, the relative paths will be formed basing on it.
You can configure the destination in such a way, that only documents without errors, documents with
errors, or all documents will be exported. Use the Documents without errors and Documents with
errors in the Export Settings.
Export can be carried out automatically or at an Operator’s command. If you are using a distributed
version, you need to create an export confirmation queue in the Project Settings to allow the Operator to
start the export. If you are using a standalone version, select Enable auto export in the Export Settings
window.

3.1.6.1.

Exporting to a file

If you want to configure exporting to a file, select Export to data files in the Type field. Specify the
general export settings and click Next.
Enter the folder path for storing exported documents in the Path field or click Browse… to use the folder
tree view.
You can export the documents of one batch to one file, or each document to a separate file (select Create
separate file for each document). You can also choose to create a separate folder for each batch (select
Create separate folder for each batch).
© 2011 ABBYY. All rights reserved.

28

Select Overwrite existing files if you want newer files to overwrite the existing ones with the same name
during export.
Next, specify the file naming options for the exported files. To do it, click File Naming Options… and
select the necessary options.
Click Next to proceed.
Select the file type (CSV, DBF, TXT, XLS, or XML) and adjust additional properties, for example, you
can change text encoding.
Click Next to proceed.
If images are exported together with data, configure the image export parameters (as described in the
Exporting Images section).
Enter a name for the export destination and click Finish.

3.1.6.2.

Exporting to a database

To enable and configure export to a database, select Export to ODBC-compatible Database in the Type
field. Select the necessary options and click Next.
Enter a Connection string or click Setup Connection... and configure the necessary parameters in the
Data Link Properties dialog box. Then select a schema from the dropdown list.
To test connection to the database, click Test Connection.
Then, you will need to define the tables and table columns of the database the Document Description field
values will be exported to. To do it, click Setup Fields Mapping...
In the left part of the Field Mapping dialog box, you will see the document’s sections and fields. Match
the tables and database fields, located in the right part, to them. If the database already includes tables for
document export, select a database table for each section and a table column for each field. The table
column format must correspond to the value of the exported field.
If the database doesn’t have tables for document export, you can enable automatic database table creation
at first export. To do it, click Create Tables Automatically. The program will create tables with the
structure suitable for exporting. Table columns will be matched to document fields.
Field groups, fields with multiple repetitions, document tables, and sections are exported to separate
database tables. The Primary and Foreign keys are used to link the main table to subordinate tables. In the
main table, a primary key is added to each entry. In the subordinate table, each entry has a foreign key that
records the value of the primary key of the corresponding entry in the main table. The primary and foreign
keys are added automatically where required. You only need to specify the field to which the key has to be
exported.
The Show linked columns option is selected by default. If you clear it, the columns with configured
export will not be displayed in the right part of the tree.
Click Next to proceed to image export settings.
You can save images to a database or as files. If you save images as files, configure the image export
parameters as described in the Exporting images section.
Note. If you chose to save images to a database, a BLOB-type table will be created for them. If you
change image export later and choose to save them to a folder, an error will occur during export,
because the text path to the image file will be exported to the BLOB-type field.
© 2011 ABBYY. All rights reserved.

29

Enter a destination name and click Finish.

3.1.6.3.

Exporting to SharePoint

ABBYY FlexiCapture 10 allows exporting document to the Microsoftтм SharePoint library. Each
document will have matching columns with values from document fields. These values can be used for
document search and indexing.
Notes.
1.

To configure export to SharePoint, you must have the Administrator’s rights. However, to carry out
the export itself, the rights of a Contributor will be enough.
2. SharePoint columns that are intended for data storage, must have either the Single line of text or the
Multiple lines of text type.
To configure export to SharePoint, select Export to SharePoint from the Type field. Select the necessary
options and click Next.
Enter the Server URL where SharePoint libraries are stored. Click Connection Settings… to configure
authentication parameters (Windows Authentication is used by default) and proxy parameters, if necessary.
Click Connect to reconnect to the server, if the connection was lost.
Select a SharePoint library from the dropdown list.
Select the document content type in the Content type field (SharePoint 2007 or later). In this case, you
will be able to configure value export to fields corresponding to the current value type. Click Setup Fields
Mapping… and configure the necessary settings in the Field Mapping dialog box.
Click Next.
Configure the image export parameters and, again, click Next.
Enter a destination name and click Finish.

3.1.6.4.

Exporting images

To configure image export, select Export to image files in the Type field. Select the necessary options
and click Next.
Enter the path to a folder for storing exported images in the Path field or click Browse… to use the folder
tree view.
You can export documents from one batch to one file (select Create separate folder for each batch).
Select Overwrite existing files if necessary.
Configure the file naming options. To do it, click File Naming Options… and select the necessary criteria
in the dialog box that opens.
If you need to redact confidential information from exported images, select Redact sensitive data from
images. Then click Select Fields to Redaction… and select the fields to be redacted.
Click Next.
Select the format for storing images in the Type field. Then configure the quality and color type of the
images saved.
© 2011 ABBYY. All rights reserved.

30

If you need to change the initial image resolution in order to reduce file size, select Change resolution to
and enter a resolution.
If you select the PDF format and select the Create searchable PDF option, the document image will be
searched in full-text mode, and the recognized text will be saved in the selected format. In this case, you
will be able to specify the recognition language: you can either choose to keep the language that was used
in the Document Definition, or select one or more languages from the lust (click Select…).
Click Next.
Enter a destination name and click Finish.

3.1.6.5.

Custom export (script)

Using the scripting method, you can create a custom export procedure which will be more flexible than if
you were using standard methods.
To create a custom export procedure, select Custom export (script) in the Type field. Select the necessary
options and click Next.
Select a scripting language (JScript®, VBScript, JScript.Compact, C#.Net, Visual Basic.Net or
JScript.Net) and enter the scripting text in the Script Editor that appears when you click Edit Script…
(for detailed description of the scripting language with examples, see the help file).

3.1.7.

Configuring Recognized Data Presentation

After the data is recognized, the Operator will see it in the document window. The data will be displayed
as a list by default, with captions matching the names of Document Definition fields. However, it is also
possible to change data display and arrange it in a convenient manner or change element headings. Data
presentation can be edited in the bottom right corner of the Document Definition Editor window.
Fields can be moved, renamed and otherwise altered. To add text, click Insert Label Box on the shortcut
menu.
Text font and size for field names and recognized data values can be specified on the Data Form tab of the
Document Definition properties dialog box (Document Definition > Document Definition
Properties…).

3.1.8.

Testing Document Definitions

Before starting mass document input, you need to test the created Document Definitions.
Document Definitions can be tested directly from the Document Definition Editor using the image the
definition was created on. To start testing, click Testing>Run Test.
Testing involves documents added to test batches, because they work with the unpublished version of the
Document Definition. These batches can be accessed from the main window of the program (View>Test
Batches). You can also access test batches from the Document Definition Editor by clicking
Batch>Switch to Test Batch….
Scripting rules can be checked directly from the Script Editor – click Tools>Check Script. This function
can be used to check script activity with different field values.
© 2011 ABBYY. All rights reserved.

31

If rule errors occur during testing, or if invalid field property values are found, edit the Document
Definition to correct these errors. When all errors are corrected, you can publish the Document Definition
and proceed to mass document input.

3.1.9.

Editing and Publishing a Document Definition

After creating a Document Definition and successfully testing it on several images, publish it to make it
accessible for recognition of working batches.
To publish a Document Definition, click Publish in the Document Definitions window (Project >
Document Definitions...).
To go back to editing the Document Definition, select it in the Document Definitions dialog box and click
Edit…. The Document Definition will not be available for editing to other users, and the latest published
version will be used for recognition. Thus, when you edit a Document Definition, you will not be in the
way of Operators’ work. Publish the Document Definition when you are finished editing it, and the new
version will become available to the users. If you don’t want to publish the edited version, you can discard
all changes and return to the latest published version. To do it, click Discard Changes in the Document
Definitions dialog box.
When a new version of the Document Definition is published, it will be used to recognize documents. For
separate documents that were previously recognized, you can change the used Document Definition
version without re-recognition (only if the version changes didn’t involve changing field locations and
recognition properties (export settings, for example, can be changed)). To do it, click Tools > Update to
Latest Version on the main menu.

3.2. Creating a FlexiLayout
Configuring FlexiLayout processing is a more elaborate task. Invoices, orders and other similar documents
are not structured (the location, size, and number of fields are different on different copies), so it is
impossible to create a common layout with fixed field positions. In the case of such documents, fields are
searched after prerecognizing the whole page, and the Document Definitions are created using keywords
and relative field locations (these definitions are called FlexiLayouts). A special program, ABBYY
FlexiLayout Studio 10 was designed to create FlexiLayouts. For more information on FlexiLayout
Creation, see the ABBYY FlexiLayout Studio 10 help file.
The FlexiLayout you created will be exported to an .afl file and then used in ABBYY FlexiCapture 10.
The FlexiLayout will be used as one of the Document Definition sections. Thus, a Document Definition
can include both structured and non-structured sections. FlexiLayouts can consist of multiple pages.
FlexiLayouts can be attached to a Document Definition when creating the latter. To do it, at the second
step of the Document Definition creation (Create New Document Definition Wizard), add the document
image, and then select Load FlexiLayout and enter the path to the .afl file with the FlexiLayout.
You can also load a FlexiLayout from the Document Definition Editor using the Properties dialog box. To
open it, click Properties... on the shortcut menu of a section. Click the FlexiLayout tab and then click
Load.... Select the required .afl file with the FlexiLayout.
When you load a FlexiLayout, all fields and their geometric marking will present on the image.
The number of fields in the Document Description must correspond to the number of fields in the
FlexiLayout. It is not recommended to add or delete fields (except for fields with no area on the image),
the set of recognized fields can be changed only by changing the FlexiLayout itself.
© 2011 ABBYY. All rights reserved.
32

Now you need to specify field properties just like for a structured document. Configure the recognition,
verification, and export properties as well as rules.

3.2.1.

Classifiers

A Classifier is a special ABBYY FlexiLayout Studio project designed for preliminary identification of
separate pages and for labeling them as a certain type (for example, by the FlexiLayout/ FlexiLayout
variant used). Classifiers are used in ABBYY FlexiCapture to classify documents at batch type level (for
Default batches, the classifier will be added at project level).
Classifiers can be used to:
• Speed up the process of selecting a Document Definition. Using a classifier allows choosing a
Document Definition according to classifying signs. You won’t have to go through all Document
Definition to choose the necessary one. An increase in speed will be especially noticeable when
working with large projects containing many Document Definitions.
• To distribute the classifying features in the classifier tree. For example, at the topmost level, you
can select documents sent in by a certain company based on a document section that bears the name
of that company. On the next level, the documents can be classified based on their titles or based o
the number of separators on a particular page.
• To manage the application of third-party FlexiLayouts. FlexiLayouts created by a third-party
developer may not match properly their documents. In this case you can use a classifier to remedy
the situation without contacting the developer.
• To speed up projects that contain Document Definitions in multiple languages. If a classifier is
used, pre-recognition of the documents is performed only twice: when classifying the documents
and when applying the selected Document Definition. Otherwise, pre-recognition has to be done
for each Document Definition language in the project.
For detailed information about classifiers, see the ABBYY FlexiLayout Studio help file.
Classifiers can be added at batch type level or at project level (the latter case is only applicable to batches
of Default type.
To add a classifier, do the following:
• In the main window, click Project > Project Properties… to add classifiers at project level, or
click Project > Batch Types…, and then Edit…) to add a classifier at batch type level;
• In the Batch Type Property dialog box, click the Recognition tab, and then click Load…;
• Select a *.cfl file with a classifier.

3.3. Specifics of Non-structured Documents
If you need to process non-structured documents with information presented in free form, for example,
contracts, letters, orders, appendices, ABBYY FlexiCapture 10 will provide a solution again. Nonstructured documents with text or images, separated by empty pages or pages with a barcode, are
processed and exported to searchable PDF files or files in image formats.
Processing of such documents usually includes converting them to electronic form and organizing their
search based on key field values.

© 2011 ABBYY. All rights reserved.

33

As a rule, key fields (for example, a contract number) are searched using a FlexiLayout created in ABBYY
FlexiLayout Studio.
If automatic key field search is impossible, the values can be entered by an Operator. To allow it, create a
Document Definition with one field (or several, if necessary) and, in the Recognition Properties of the
field(s), select Don’t recognize (Key from Image field – will be entered manually). The Operator will
be prompted to enter the key field value manually when verification is started.
To store documents, you need to configure the export. Key field values can be exported to files or a
database, and document images can be saved in the desired format. To export images, on the Image tab of
the Export Settings dialog box, click Save Document Images and configure the image saving parameters.
You can save document images to graphic files or searchable PDF documents.
Consider page assembly into documents carefully. In the case of non-structured documents, it may be hard
to define which document a page refers to. It is recommended to separate documents with empty pages or
pages with barcodes to allow automatic assembly of non-structured documents. Then, when adding images
to a batch (from a scanner, file, or during Import Profile creation), select For images separated by and,
from the dropdown list, choose either blank pages or pages with barcode, depending on the pages used
as separators. Pages will be assembled into documents automatically – pages will be added to the current
document until a separator page is encountered.

4. Configuring Project Properties
Project properties can be configured in the Project Properties window. To open it, click Project >
Project Properties…
The Project Properties window has seven tabs. The General tab describes general project properties – the
name, description, and other. The Stage type tab allows you to set up the processing of events at different
processing stages and their appearance.
The rest of the tabs are identical to those in the Batch Type properties window (see Configuring Batch
Types) and describe the properties of Default-type batches.
The General tab allows configuring the following project properties:
• Name;
• Description;
• Export root path — path to a folder, from which relative file export paths will stem after a project
has been uploaded to the server. The path is specified in UNC format.
You can also view the project file name and its location in the folder tree (or for projects on the
Application Server, its GUID.
The rest of the tabs are identical to those in the Batch Type properties window and are used to configure
the Default batch type.
When configuring project properties, you can specify the order list of the Document Definitions used. As
opposed to the batch types, this operation is carried out from the Document Definitions window (Project
> Document Definitions…).
FlexiLayouts are matched in the same order they are listed in this window (top to bottom). To change the
order of a document, use the Up and Down buttons.
As a rule, the recognition process consists of consecutive matching of all added FlexiLayouts and checking
their quality, after which best one is selected. To speed up Document Definition matching, select Use first
© 2011 ABBYY. All rights reserved.
34

acceptable flexible layout. In this case, if a FlexiLayout is matched, the rest won’t be considered. This
option may be useful when you have many different FlexiLayouts as it will decrease the overall
recognition time.
A Document Definition can be temporarily disabled. To do it, clear the Enabled option in the list of
Document Definitions. To enable the Document Definition, select this option.

5. Configuring Batch Types
ABBYY FlexiCapture 10 supports document processing in batches: a batch is created before processing,
and document images are added to the batch to be processed together. Batches can be created
automatically or manually during image import (from a scanner or image file). Batch processing settings
are configured in the Batch type properties. You can create several batch types with the most commonly
used processing settings. In this case, the Operator will only have to specify the batch type.
Batch types define the following document processing parameters:
• Image preprocessing method;
• List and matching order of the Document Definitions, and the Classifier used;
• Batch integrity check;
• Default settings for manual export;
• Export settings for unrecognized documents;
• Batch processing.
Batch types also define the list of batch registration parameters, i.e. textual information characterizing a
given batch.
Batch types are created within projects. To view the list of batch types, click Project > Batch Types… on
the main menu.
To create a new batch type, click New…. Then, configure the necessary parameters in the Create New
Batch Type window.
To edit a batch type, select it and click Edit…. The Batch Type Property dialog box will open.
Batch type settings are divided into six groups with a separate tab for each of them. Each group also has a
corresponding stage during batch type creation.
Note: If there are several independent workflows and Document Definitions for which monitoring and
collecting statistics should be performed separately, it is recommended that different projects should be
created. Otherwise, it is recommended that different batch types should be created within a project.

5.1. General
The general properties are as follows:
• Name;
• Description;
• Registration parameters. The registration parameters are textual properties allowing identification
of a given text. The scan date, the Scanning Operator’s name or other information can be used as
such properties. The registration parameters are specified when creating a batch of the selected
type. Registration parameters can be either required or optional.
© 2011 ABBYY. All rights reserved.

35

5.2. Image Preprocessing
The following document creation and image processing parameters can be configured for a batch type:
• Create new document. A new document can be created automatically when Document Definition
is matched, for every image file, or for image files separated by blank pages or pages with a
barcode (of certain type or value). If the separator pages are not to be processed, they can be
deleted by selecting Delete separator pages.
• Image Processing. The following image processing parameters can be specified:
 Despeckle images;
 Convert color and gray images to black and white;
 Rotate images by (90º (counter)clockwise or 180º (upside down);
 Use black separators to correct skew;
 Use black squares to correct skew;
These settings will be used by default when an Operator adds documents to a batch of this type without
using import profiles.

5.3. Recognition
The following recognition parameters can be configured:
• Document Definitions. You can use all Document Definitions in the project, or select the ones to
be used for the current batch type. If you use a list of Document Definitions, you can specify their
matching order for the batch type: the definitions will be matched in the same order in which they
are presented on the list (top to bottom). To change the order of Document Definitions, use the Up
and Down buttons.
• FlexiLayout. As a rule, all loaded Document Definitions are matched consecutively. Then,
matching quality is checked, and the one with the best quality is chosen. To speed up Document
Definition matching, select Use first acceptable flexible layout. In this case, if a FlexiLayout is
matched, the rest won’t be considered.
• Classification Tree. A classifier can be loaded for batch type or project to select FlexiLayouts. To
select a classifier, click Load… and, in the dialog box that opens, select a classifier file. To detach
the classifier, click Detach.
• Delete blank pages during recognition – select this option if you want blank pages to be deleted.

5.4. Event Handlers
You may create your own scripts that will perform an action for an event. Simply select an event in the list
and click the Edit Script… button. In the dialog box that opens, type the code of the script and debug it.
Select File > Save or press Ctrl+S to save the script.
The script will be disabled by default. To enable the script, select the option to the left of its name.

5.5. Export
The export parameters of recognized documents are specified for Document Definitions. For a batch type,
you can specify the export parameters of unrecognized documents. To export the images of unrecognized
© 2011 ABBYY. All rights reserved.

36

documents (i.e. those for which no matching Document Definitions have been found), select the Export
unrecognized documents option and specify the export parameters.
You can also set up the program to delete documents upon export. Simply specify how long documents
should be stored after export.

5.6. Workflow
5.6.1.

Standalone

The following workflow parameters can be configured for the Standalone version:
• Automatic batch export, if there are only few uncertainly recognized characters. For the batches to
be exported automatically, select Export batch automatically if there are no errors or
warnings, and percentage of uncertain symbols is equal or less than and enter the maximum
allowed percent of uncertainly recognized characters for the export to be carried out automatically.
• Document deletion after export. To delete documents after export automatically, click Delete
processed documents after export.

5.6.2.

Distributed

The following workflow parameters can be configured for the Distributed version:
• Automatic processing. In this mode, no human involvement is required and all operations are
automatic: documents are imported, recognized, and exported. If an error occurs, failed documents
are placed into the Exceptions queue.
• Regular processing. In this mode, you can select the processing stages to be used and allow or
prohibit the use of Web stations at certain stages. You can also specify the following processing
parameters:
 Process whole batches. By default, jobs are created using a certain number of documents from
one batch. If you select this option, however, each job will include an entire batch.
 Skip verification and data verification if percentage of characters need verification is
equal or less than. If you select this option, documents for which good recognition quality has
been achieved, will not be included into verification jobs. Documents will skip verification if
they contain no characters to verify or if the number of unreliably recognized characters is
lower than the value you specified.
• Extended processing. In this mode, you can not only set up pre-defined processing stages, but also
create new ones and change the order of the stages. You can specify various parameters for a stage,
including the conditions when a document must be placed into a certain stage or routed. These
conditions can be specified by logical rules or by scripts.

5.7. .Net Assemblies
If required, you can connect .Net assemblies to a project. Simply click the Add… button and provide the
path to the assembly.

© 2011 ABBYY. All rights reserved.

37

6. Configuring Image Import
In the Distributed version, images are imported in a special application – Scanning Station. However,
Verification Operators and Senior Verification Operators can also add images to batches. Images can also
be automatically imported from Hot Folders.
Import profiles allow specifying the import and image processing parameters. In the Distributed version,
import profiles are generally used to process Hot Folders, because Verification Operators add images to
correct assembly errors, and not to process streaming documents. In the Standalone version, an Operator
can also use import profiles to quickly import images using one button.
To add an import profile, click Project > Image Import Profiles… on the main menu of the program. In
the dialog box that opens, you can create new import profiles, and edit, delete and copy the existing ones
(Figure 16).
To create a new import profiles, start the Import Profile Wizard by clicking New…
First, choose the image source. You can either choose to get an image from a scanner or a Hot Folder (the
folder in which new images will be searched). If you want to add images from a Hot Folder, make sure you
have the necessary rights to open it and write to it. If you choose a scanner as the image source, make sure
it is connected properly.
Creating an import profile using a scanner
1. Select Scanner as the image source and click Next.
2. Configure the scanning and image processing options. Select the method of interacting with the
scanner from the Style of settings dialog dropdown list: select FlexiCapture scanning settings to
use the dialog box from ABBYY FlexiCapture or System scanning settings to use the dialog box
from the scanner driver. Click Next.
3. Configure the document assembly and image preprocessing settings. For example, you can choose
to despeckle images (if the image quality may be low or the image may contain rubbish), convert
them to black and white, rotate, and disable skew correction. Click Next when you are finished.
4. Now you can change the default import profile name and add a comment.
Creating an import profile using a Hot Folder
1. Select Hot Folder as the image source and enter the path. You can choose a POP3- or FTP-server,
mailbox or local or network folder as a Hot Folder. Then click Next.
2. Configure the image loading options. You can select Check Hot Folder every and enter the time
interval between image checks. In Batch Settings, select one of the options to define the batch or
batches the new images will be added to. In the Number of files to add dropdown list, select of the
values to define the number of files to be added to the specified or newly created batch. Click Next.
3. Configure the document assembly and image preprocessing settings, just like if you were creating
an import profile using a scanner. Click Next when you are finished.
4. The Import Profile Wizard will prompt you to configure Hot Folder purge options: successfully
imported images as well as images with import errors can be deleted or retained/moved. Click Next
when you are finished.
5. Now you can change the default import profile name and add a comment.
© 2011 ABBYY. All rights reserved.

38

Figure 16. Image Import Profiles dialog box

Automatic Hot Folder checking is initiated as follows:
• In Standalone version – by selecting Automatically check Hot Folders in the Image Import
Profiles window.
• In Distributed version – for individual projects, using the Processing Server Monitor, in the Hot
Folders section.

7. Uploading a Project to the Server
In the Standalone version of the system, Operators can start working with a project as soon as it is
configured. In the Distributed version, the created project must be uploaded to the Application Server. To
do it, click File > Upload Project to Server… and, in the dialog box that opens, enter the Application
Server address in the http:// format. Only the Application Server Administrator can upload
the project to the server.
When the project has been uploaded to the server, you must assign roles to Operators using the
Administration and Monitoring Console. If Hot Folders are used in the project, enable them using the
Processing Server Monitor. For detailed information on administering the system, see the
Administrator’s Guide.

8. Keyboard Shortcuts
8.1. Main window
New Project…

Ctrl+Shift+N

Open Project…

Ctrl+Shift+O

Save

Ctrl+S

New Batch…

Ctrl+N
© 2011 ABBYY. All rights reserved.

39

Load Images…

Ctrl+O

Scan Images…

Ctrl+K

Import Images

Ctrl+I

Export

Ctrl+U

Export Data to Files…

Alt+Shift+S

Export to Database…

Alt+Shift+D

Undo

Ctrl+Z

Redo

Ctrl+Y

Cut

Ctrl+X

Copy

Ctrl+C

Paste

Ctrl+V

Delete

Del

Select All

Ctrl+A

Find…

Ctrl+F

Find Next

F3

Go to Next Document

Ctrl+D

Go to Previous Document

Ctrl+Shift+D

Despeckle Image

Ctrl+Alt+K

Invert Image

Ctrl+Alt+V

Rotate Image 90º clockwise

Ctrl+W

Rotate Image 90º counterclockwise

Ctrl+Shift+W

Test Batches

Ctrl+Shift+B

Batches

Ctrl+B

Details

Alt+1

Thumbnails

Alt+2

Full Screen

F11

Refresh

F5

Properties…

Alt+Enter

Document Editor: Image Mode

Ctrl+1

Document Editor: Data Mode

Ctrl+2

Zoom In

Ctrl +Num+

Zoom Out

Ctrl+Num–

Thumbnails: Increase Size

Ctrl+Shift+Num+

Thumbnails: Decrease Size

Ctrl+Shift+Num–
© 2011 ABBYY. All rights reserved.

40

Analyze

Ctrl+E

Match Document Definition…

Alt+Shift+E

Recognize

Ctrl+R

Run Verification

F7

Next Item to Verify

F4

Previous Item to Verify

Shift+F4

Next Assembly Error

F9

Previous Assembly Error

Shift+F9

Next Uncertain Character

F8

Previous Uncertain Character

Shift+F8

Next Rule Error

F6

Previous Rule Error

Shift+F6

Document Definitions…

Ctrl+T

Batch Types…

Ctrl+Shift+T

Image Import Profiles

Ctrl+Shift+I

Update to Latest Version

Alt+Shift+U

Re-analyze

Ctrl+Alt+E

Re-recognize

Ctrl+Alt+R

Re-check Rules

Ctrl+F6

Check Batch Integrity

Ctrl+Shift+E

Help Topics

F1

Exit

Alt+F4

8.2. Document Definition Editor Window
Add Page…

Ctrl+P

Add Document Section…

Ctrl+Alt+S

Document Definition Properties

Ctrl+T

Save

Ctrl+S

Undo

Ctrl+Z

Redo

Ctrl+Y

Cut

Ctrl+X

Copy

Ctrl+C

Paste

Ctrl+V
© 2011 ABBYY. All rights reserved.

41

Delete

Del

Delete Region

Shift+Del

Select All

Ctrl+A

Select by Type

Ctrl+Shift+A

Group

Ctrl+G

Ungroup

Ctrl+Shift+G

Copy Text from Image

Ctrl+Alt+C

Create Field: Text

Alt+Shift+T

Create Field: Checkmark

Alt+Shift+C

Create Field: Checkmark Group

Alt+Shift+M

Create Field: Barcode

Alt+Shift+B

Create Field: Picture

Alt+Shift+P

Create Field: Table

Alt+Shift+L

Create Field: Group

Alt+Shift+G

Despeckle Image

Ctrl+Alt+K

Invert Image

Ctrl+Alt+V

Rotate Image 90º Clockwise

Ctrl+W

Rotate Image 90º Counterclockwise

Ctrl+Shift+W

Data Form

Alt+F2

Properties

Alt+Enter

Static Elements

Ctrl+1

Field Regions

Ctrl+2

Show Document Structure

Alt+F1

Fields

Alt+1

Pages

Alt+2

Zoom In

Ctrl+Num+

Zoom Out

Ctrl+Num–

Run Test

Ctrl+R

Autodetect Objects

Ctrl+D

Check Document Layout

F9

Match Section

Ctrl+E

Help Topics

F1

Close

Alt+F4
© 2011 ABBYY. All rights reserved.

42

8.3. Group Verification Window
Confirm All

Enter

Postpone All

Ctrl+Enter

Toggle

Space

Next Page

Page Down

Previous Page

Page Up

Undo

Ctrl+Z

Redo

Ctrl+Y

Select All

Ctrl+A

Show Character Image

F2

Full Screen

F11

Show Field Image

Ctrl+I

Show Field Image: On Top

Alt+1

Show Field Image: On Bottom

Alt+2

Image Scale: Zoom In

Ctrl+Num+

Image Scale: Zoom Out

Ctrl+Num–

Help Topics

F1

Exit

Alt+F4

8.4. Field Verification Window
Confirm Field

Enter

Postpone Field

Ctrl+Enter

Next Uncertain Character

F4

Previous Uncertain Character

Shift+F4

Next Field

Page Down

Previous Field

Page Up

Undo

Ctrl+Z

Redo

Ctrl+Y

Cut

Ctrl+X

Copy

Ctrl+C

Paste

Ctrl+V

Delete

Del
© 2011 ABBYY. All rights reserved.

43

Delete All

Alt+Del

Select All

Ctrl+A

Insert Line Break

Shift+Enter

Merge Characters

Ctrl+M

Analogous Fields

Alt+F3

Show Character Image

F2

Full Screen

F11

Recognized Text

Alt+F1

Character Image Cutting

Alt+F2

Show Field Image

Ctrl+I

Show Field Image: On Top

Alt+1

Show Field Image: On Bottom

Alt+2

Image Scale: Zoom In

Ctrl+Num+

Image Scale: Zoom Out

Ctrl+Num–

Help Topics

F1

Exit

Alt+F4

© 2011 ABBYY. All rights reserved.

44



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Author                          : © 2011 ABBYY. All rights reserved.
Comments                        : 
Company                         : ABBYY
Create Date                     : 2012:04:22 16:38:31+04:00
Modify Date                     : 2012:04:22 16:43:07+04:00
Source Modified                 : D:20120422123611
Subject                         : ABBYY FlexiCapture 10
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2012:04:22 16:43:07+04:00
Creator Tool                    : Acrobat PDFMaker 10.1 for Word
Document ID                     : uuid:7b0943d1-b710-41be-9fa9-bc36ce84161f
Instance ID                     : uuid:986657a7-9e4f-4793-b428-67d52d6e55d2
Format                          : application/pdf
Title                           : Project Setup Guide
Description                     : ABBYY FlexiCapture 10
Creator                         : © 2011 ABBYY. All rights reserved.
Producer                        : Adobe PDF Library 10.0
Keywords                        : 
Headline                        : ABBYY FlexiCapture 10
Page Layout                     : OneColumn
Page Count                      : 44
EXIF Metadata provided by EXIF.tools

Navigation menu