aitronic MOBISCAN Barcode and RFID Reader User Manual
aitronic GmbH Barcode and RFID Reader Users Manual
aitronic >
Users Manual
Operating Manual PMS, HTE and MobiScan Family with Standard Program Version 6 Operating Manual PMS, HTE and MobiScan Family with Standard Program Version 6 We do not only deliver our mobile Terminals with Standard Software... we are also developing custom specific • applications for these devices, • PC applications, • hardware and consult you concerning • • • • creation of mobile data capturing concepts, questions coming up with barcodes, hardware problems, PC problems. Please contact: aitronic GmbH Max-Planck-Str. 19 D-33104 Paderborn Phone: Fax: Internet: eMail: +49(0)5254/9969-0 +49(0)5254/9969-40 http://www.aitronic.de info@aitronic.de __________________________________________________________ Copyright aitronic GmbH, 2004 All rights reserved, especially also excerpts for translation, printing, copying or similar processes. Possibility of delivery and technical modification reserved. Contents _________________________________________________________________ 1. Introduction .................................................................... 1-1 2. Warning Hints ................................................................. 2-1 Laser Scanner Module............................................................................... 2-1 Accus......................................................................................................... 2-1 3. Security & Regulatory.................................................... 3-1 4. Care Instructions............................................................ 4-1 Care of the Scanner .................................................................................. 4-1 Dealing with the Devices Markings ............................................................ 4-1 Repairing Screen Damages....................................................................... 4-1 5. Communication/Charging Adapter ............................... 5-1 6. Installation of PC Software MTWIN............................... 6-1 7. Introduction to Operation .............................................. 7-1 Switching on/off ......................................................................................... 7-3 LCD Displays............................................................................................. 7-3 Scanner Handling ...................................................................................... 7-4 Manually Data Entry .................................................................................. 7-5 Deleting Characters................................................................................... 7-5 Deleting Entry Field ................................................................................... 7-5 Select next Entry Field............................................................................... 7-6 Closing Entry and storing the Record ........................................................ 7-6 8. System Functions .......................................................... 8-7 8.1 Cold Start / Initialization.......................................................................... 8-7 8.2 Reset Button ............................................................................................ 8-9 Warm Start .............................................................................................. 8-11 Cold Start / Initialization ........................................................................... 8-11 Calling the Boot Program......................................................................... 8-11 8.3 Battery Low Procedure ......................................................................... 8-12 8.4 Menu System ......................................................................................... 8-13 Calling/leaving the Menu System............................................................. 8-13 Selecting Menus ...................................................................................... 8-13 Selecting Menu Functions ....................................................................... 8-14 ____________________________________________________________________ aitronic 2 _________________________________________________________________ Contents Executing Menu Functions .......................................................................8-14 Returning to Menu System .......................................................................8-14 Menü: 1 APPLICATION............................................................................8-14 Menü: 2 DATA MEMORY.........................................................................8-15 Menü: 3 COMMUNICATION ....................................................................8-15 Sub-Menü: 3 DECT Functions..................................................................8-16 Menü: 4 SETUP .......................................................................................8-17 8.5 Function Barcodes.................................................................................8-18 Commands ...............................................................................................8-18 Program Selection....................................................................................8-19 Standard Barcode Menu ..........................................................................8-20 8.6 Charging the integrated Accumulators ................................................8-26 8.7 Error Messages ......................................................................................8-27 8.8 Error Diagnostics ...................................................................................8-31 9. Software Update ............................................................. 9-1 10. Technical Data ......................................................... 10-1 Mobile Terminals PMS 1200/1500 ...........................................................10-1 Mobile Terminals HTE 1800/1900 and MobiScan-6x/8x...........................10-2 Scanner Modules .....................................................................................10-3 11. Accessories ............................................................. 11-1 Protection cap for PMS ............................................................................11-1 Belt Holster for MobiScan 6x ....................................................................11-1 Redirection Optic for HTE ........................................................................11-1 RS-232 Cable for HTE and MobiScan......................................................11-2 2-Bay Charging Cradle for HTE 1900.......................................................11-2 Cradle MobiScan 6x PTR .........................................................................11-2 2-Bay Cradle MobiScan 6x/8x UDS..........................................................11-3 1-Bay Cradle UDS with RS-232 and LAN Interface..................................11-3 Cradle 1-fach UDS ...................................................................................11-3 Accesspoint for DECT RF Network ..........................................................11-4 12. Recycling Orders ..................................................... 12-1 Battery Order............................................................................................12-1 IT Salvage Devices Order ........................................................................12-1 13. Additional ManualsECHNICAL MANUAL ..................... 13-1 APPLICATION PROGRAMMING MANUAL ..........................................................13-1 CONNECTIVITY & APPLICATIONS ...................................................................13-1 aitronic ___________________________________________________________________ Contents _________________________________________________________________ WINDECT .................................................................................................. 13-1 DECT RF NETWORK ................................................................................. 13-1 14. Standard Program MTSTD ...................................... 14-1 Initialization following Cold Start .............................................................. 14-1 Data Capturing ........................................................................................ 14-2 Displaying Records.................................................................................. 14-3 Modifying/deleting/undeleting a Record................................................... 14-3 Function Keys.......................................................................................... 14-3 Data Transmission................................................................................... 14-4 Erasing the Data Memory ........................................................................ 14-6 Test Barcodes ......................................................................................... 14-7 ____________________________________________________________________ aitronic __________________________________________________________________________ Before working with your device you should study this manual carefully. All informations in this manual are given without any guarantee and may be altered by us without any prejudice. We take care to keep our products errorfree and on the latest technical level. As possible we try to stay compatible to our delivered products. Although we take much care in producing and testing our software it is not possible to guarantee the functionality allways and completely under all thinkable operating conditions. Attention: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. For personal or material damage resulting directly or indirectly from the usage of our devices or software aitronic GmbH cannot take over liability. This manual or parts of it are not allowed by aitronic GmbH to be copied or mailed in any way. Copies of the software may only be used for backup purposes but may be not given to third ones. Trade-marks and trade-names in this manual which are not specially be marked are only therefore not free of any rights. We are willingly to help you with any problems or questions concerning our products. Please consult: aitronic GmbH Max-Planck-Str. 19 D-33104 Paderborn Phone: Fax: Internet: eMail: +49(0)5254/9969-0 +49(0)5254/9969-40 http://www.aitronic.de info@aitronic.de ____________________________________________________________________ aitronic Introduction______________________________________________________________ 1-1 1. Introduction The mobile terminals PMS 1200/1500, HTE 1800/1900 and MobiScan from aitronic are usable in several ways for scanning barcodes and manually data capturing. Different device types and options are available (refer to Technical Manual, chapter 1 Device Types). Depending on the type of the serial interface off- and online network applications can be implemented. For all devices in this manual the designation MT (Mobile Terminal) is used. All PMS 1200/1500 device types in this manual are named PMS, all HTE 1800/1900 device types are named HTE. In general devices with keyboard include all functions of devices without keyboard. In function descriptions which concern only to devices with keyboards a particular reference is made. ____________________________________________________________________ aitronic Warning Hints ____________________________________________________________ 2-1 2. Warning Hints Laser Scanner Module The mobile terminals PMS/HTE/MobiScan are equipped with a low power laser diode for visible light. The wave length is 650 nm and the nominal laser power is 1,2 mW. The laser scanner meets the CDRH/IEC Class II requirements. As with other strong light sources the operator should avoid looking directly into the laser beam. Occasionally irradiation with CDRH/IEC Class II laser light is not known to be injurious. The required security labels are located below the laser light window. Never open the laser module or perform any maintenance work at the module because the laser security specification may be injured. The laser module may only be repaired in the factory. Accus Attention! In case of improper handling of the accus there will be danger of explosion. In case of waste disposal of used accus you should pay attention to the Recycling Orders (look for chapter Recycling Orders/Battery Order). At this point we want to explicitly attention to that we don’t overtake guarantee for damages which are the consequence of wrong dealing with the devices. ____________________________________________________________________ aitronic Security & Regulatory______________________________________________________ 3-1 3. Security & Regulatory This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ____________________________________________________________________ aitronic Care Instructions _________________________________________________________ 4-1 4. Care Instructions Your data capturing device with integrated laser scanner module is a high grade and robust unit consisting of electronic and laser optic devices. An faulty treatment of this device can considerable affect function and efficiency. To guarantee lasting and constant operation you should consider the following care instructions! Care of the Scanner The red scanner screen of your terminal forms and the inner resided scanner module form an optical unit. This screen is provided with a special coating. A damage of this coating i.e. by scratches may lead to problems when scanning barcodes. Because of this a clean and moist cloth should be used when cleaning the screen. Before rough dirt may be removed with a soft brush. Cleaning agents may not be used for the screens care and cleaning. Terminal of the MobiScan family habe an aluminum case. All other scanners from ours have a plastic case. Although both are robust materials for cleaning only a soft cleaning angent should be used. Dealing with the Devices Markings The attached marking labels (warning and security labels) may not be removed on principle. They are the legitimation for the operation with this terminal. Making the terminals data plate or informations on the data plate (i.e. the serial number) unrecognizable should be avoided. Missing information on the data plate may lead to a more difficult identification. This may further lead to problems which couldn’t be solved by telephone. In this case the terminal must be sent in. Further we recommend the attachment of additional information (i.e. department or personal numbers) labels with plastic back. Simple paper back labels aren’t durable enough. In that way sticking parts may smudge the scanner screen. In this case on the one hand the scanner function will be affected, on the other hand a cleaning without ignoring the above instructions woun’t possible because a solvent would be required. Repairing Screen Damages In case of overstress the screen may be loosen. We explicitly attention to that self repairing with short time glue may affect in such strong way that the screen or the casing must be changed. ____________________________________________________________________ aitronic Communication/Charging Adapter ____________________________________________ 5-1 5. Communication/Charging Adapter The Communication/Charging-Adapter deals for connection a mobile terminal to an RS232 port of a PC or other computer. The Communication/Charging-Adapter is equipped with a fast charging device, which also deals for loading the integrated mobile teriminal accus. Starting Operation 1. Switch of your computer. 2. Connect the RS-232 cable to the desired COM port of your PCs. 3. Connect the Communication/Charging-Adapters main plug to a 220 V AC outlet. The ground protection must be connected. The Communication/ ChargingAdapters LED glowes green. 4. Now switch on your computer an start your application program. 5. Connect the mobile terminal to the am Communication/Charging-Adapter. The Communication/Charging-Adapters LED now glows orange. The trickle charging mode is active an the mobile terminal is ready for data communication. ____________________________________________________________________ aitronic Installation of PC Software MTWIN ___________________________________________ 6-1 6. Installation of PC Software MTWIN The PC Software MTWin is used for data exchage with mobile terminals. To install the software execute SETUP.EXE in the directory MTWin of the supplied CD and follow the installation instructions. You also can download MTWIN from our website www.aitronic.de and then Service/Downloads/Communcation Software. ____________________________________________________________________ aitronic System Functions _________________________________________________________ 7-1 7. Introduction to Operation The following table shows the standard key functions of devices with numerical keyboard: Key Function without Shift Key Function with Shift Key Holding down the shift key and inputting a decimal number from 32 to 127 any printable ASCII character can be entered in input fields which allow these kind of input. 0...9 Digits 0 - 9 In case of empty entry mask: MENU. OFF In decimal entry fields (quantity field in Standard Program1): decimal point. scan one position backward HOME scan one position forward END SHIFT SHIFT CE CANCEL ENTER By means of the Standard Barcode Menu (refer to page 8-20) the same functions can be performed as with the keyboard. This can be required with devices missing a keyboard (PMS 1200). ____________________________________________________________________ aitronic 7-2 _______________________________________________________ System Functions The following table shows the standard key functions of devices with alphanumerical keyboard: Key Function without Shift Key Function with Shift Key On/Off SHIFT Shift 0...9 Characters 0 - 9 Alpha Character Sonderzeichen Special Character Alpha Character CLR CE Alpha Character DEL CANCEL Alpha Character ↵ ENTER MENU In case of empty entry mask: MENU. In decimal entry fields (quantity field in Standard Program1): decimal point. F1...F8 Function Keys Are not used in the Standard Software but can be used in the application programming. Alpha Character scan one position backward Input Mask: Alpha Character Data memory: HOME scan one position forward Input Mask: Alpha Character Data memory: END aitronic ____________________________________________________________________ System Functions _________________________________________________________ 7-3 Switching on/off The device switches on in case of • hitting the keyboard (devices with numerical keyboard) respectively the power on key (upper left, devices with alphanumerical keyboard), • pressing the scanner switch, • connecting the serial interface to a PC where an application is active which has activated the RTS signal of the serial interface (not with devices with RF module and LAP-EC). In case of inactive signal CTS (this means: no charging/ transmission adapter is connected or on the PC no application is active which has set the serial interfaces signal RTS) and for the duration which is adjusted with configuration parameter Power Off Time no operation is performed (hitting of keyboard/scanner switch or data transmssion with a RF device) the device powers off automatical to economize the integrated accumulators and therefore to guarantee an long operation time. Manually switching off is performed by • holding down key SHIFT and pressing key * in case of using a device with numerical keyboard. After releasing both keys the device switches off itself. pressing the power on key (upper left) in case of using a device with • alphanumerical keyboard. LCD Displays Normally the actual entry mask for article number (Standard Program 1 and 2) and quantity (only Standard Program 1) is shown. Another display content (program message or the a stored record in case of scanning through data memory) keeps staying on LCD until the scanner switch or the keyboard is hit or until the device is switched off. With RF devices (only in case of an actual entry mask) the data net activity is shown on the last LCD position. The symbol ∗ indicates that the device was polled from the RF server with its address (serial no.). The symbol o indicates that the device was polled from the RF server with the login address (000000). Normally this two symbols are changing alternately in case of an logged in device. If only the symbol o is shown the device is not logged in. If a device resides outside the active RF area or the RF server is not active no one of those two symbols are shown. ____________________________________________________________________ aitronic 7-4 _______________________________________________________ System Functions Scanner Handling Testing the Scanner Hold the scanner above a light surface and press the trigger. Now you should se the red laser beam on the surface and with the PMS 1500 the LED 'Scanning' should be on. Scanning Barcodes Hold the scanner in front of a barcode and press the trigger. Notice the fol-lowing operating tips: • Vary the scanner position in that way that the laser beam sweeps the middle of the barcode and overlaps it at both sides. • The larger the barcode, the farther away you should hold the scanner. • Hold the scanner closer for barcodes which are printed with a higher density. • Hold the scanner not in a right angle to the barcode. In this position light can bounce back into the scanner and influence the decoding perfor-mance or even prevent decoding at all. When the scanner has read the barcode • you will hear the 'Decode Beep' (standard configuration: short double beep), • with the PMS 1500 the LED 'Good Read' will turn on for a short time (standard configuration: 3 seconds), • and the laser beam will be switched off. If you follow these instructions and fail to scan read section "If nothing functions" below. What does the different beeps mean? Listen to the 'Decode Beep' (standard configuration: short double beep). This means that the barcode has been decoded successfully. A long error beep means that the selected function respectively the read barcode is not valid. If nothing functions If you follow previous instructions and fail to scan: • Ensure that the accumulators are charged. • Make sure that the MT is configured for the barcode type which should be read. • Make sure that the barcodes are not demaged or dirty. Check the barc-ode print quality. If you have performed these checks and the barcode still cannot be decoded contact your authorized distributor. aitronic ____________________________________________________________________ System Functions _________________________________________________________ 7-5 What should be notice with laser light devices The laser scanners use a low-powerlaser diode for visible laser light. As wiht any bright light source the user should avoid staring directly into the laser beam. Momentary exposure to a CDRH Class II laser is not known to be harmful. The required safety labels are placed below the laser light window and above the trigger switch. Manually Data Entry Enter article number and quantity manual with keys 0…9 The cursor points to the next entry position. Use key C (respectiveley CLR in case of devices with alphanumeric keyboard) to delete the character left beside the cursor. Use key + to close the entry of the article number and to go to the quanity entry field. Use key * (respectiveley MENU in case of devices with alphanumeric keyboard) to enter the point in case of decimal entries. Pressing key + when the cursor resides in the quanity entry field the article number and the quantity will be stored into data memory and the empty entry mask is shown again. Deleting Characters By pressing key C (respectiveley CLR in case of devices with alphanumeric keyboard) the character left beside the cursor is deleted. In case of empty entry field the cursor jumps to the previous entry field. Single digits of a scanned barcode can't be deleted. In this case there is only the option to delete the entire entry field. Deleting Entry Field Devices with numerical Keyboard By holding down key SHIFT and pressing key C the entire entry field in which the cursor resides is deleted. Devices with alphanumerical Keyboard Press key DEL instead of SHIFT C ____________________________________________________________________ aitronic 7-6 _______________________________________________________ System Functions Select next Entry Field If there has been at least one digit entered in the article number field and there is a quantity field available (Standard Program 1) this may be selected by pressing key +. Closing Entry and storing the Record If there has been at least one digit entered in the last entry field the whole entry is closed by pressing key +. Storing of the record is performed if • the configuration parameter Data Destination Memory is set, or the configuration parameter Data Destination SIO is set but the RS-232 • signal DTR is not active. The record is transmitted to the serial interface if the configuration parame-ter Data Destination SIO is set and the RS-232 signal DTR is active. After storing respectively transmitting the record to the serial interface the next empty entry mask is shown. aitronic ____________________________________________________________________ System Functions _________________________________________________________ 8-7 8. System Functions 8.1 Cold Start / Initialization Enable Function Barcodes Ö€$X1@ä Initialization (Cold Start) Ö€öö$$$$$+ä ATTENTION:Stored data will be lost and the device will be initialized completely. Disable Function Barcodes Ö€$X0<ä At first power up of the PMS/HTE after a software update or after loss of the RAM voltage the initialization takes place with the execution of the following steps: • • • • • • • • Boot program start and initialization. Indication of hardware type with a distinct count of clicks: 2 clicks: PMS 1200, 3 clicks: PMS 1500, HTE 1800/1900, MobiScan, Test of keyboard/display interface in case of devices with keyboard, Output of a long beep, RAM Check, is indicated by a distinct count (depends on the size of data memory) of short beeps: 2 short beeps: 32 K data memory, 8 short beeps: 128 K data memory, 32 short beeps: 512 K data memory. Flash ROM Check. In case of errorfree checksums of all 4 Flash ROM Banks the operating system is started and initialized. Otherwise the device remains in the boot program and the required software update must be loaded. Display of the Device Information. − Device name and size of data memory, − Application program name and version (AP), − Operating System name and version (OS), − Decoding Software name and version (DS), − Boot Program name and version (BP), − Library name and version (LB). ____________________________________________________________________ aitronic 8-8 • • • _______________________________________________________ System Functions − Keyboard Controller name and version (KC). Loading of user configuration. Optional input of a password up to 15 digits (only devices with keybard; with devices without keyboard the password must be entered via the appropriate menu function). The password must be confirmed by entering it a second time. Only in case of confirmity the password is stored. If there is no password used both inputs can be skipped with key +. The password is used by the operating system to protect the distinct menu functions. RF communication devices now perform an automatic login into the RF net in case of configuration parameter 'Auto Login' set (is set in the Standard Program). In case of configuration parameter 'Manual Login' set the login must be performed via the appropriate menu function. aitronic ____________________________________________________________________ System Functions _________________________________________________________ 8-9 8.2 Reset Button ATTENTION Don't press the reset button during the device programmes a Flash ROM sector (i.e. at software update or when saving the User Configuration). Otherwise the Flash ROM sector will be destroyed and the software must be loaded new. In case of sector 1 (contains the boot program) the Flash ROM must be changed. By means of the reset button a warm start can be performed, • a cold start can be performed, • • the boot program can be called. In this way the device can be resetted. This function is only required when the device not reacts when the keyboard is hit or when it receives a SIO command. Two pages ahead this three functions are described detailed. To get to the reset button of Mobile Terminals from type PMS 1200/1500 with RS-232- or IR-Interface the • handle grip cap must be removed. of Mobile Terminals from type MobiScan-60 the casing lid on the right side • must be removed. With all other Mobile Terminals the reset button can be pressed by means of a thin tool (i.e. bowed up paper clip) through a little hole in the housing. The pictures on the next page show the position of the reset button at the different Mobile Terminals types. ____________________________________________________________________ aitronic 8-10 _______________________________________________________ System Functions aitronic ____________________________________________________________________ System Functions _________________________________________________________ 8-11 Warm Start • • • • Switch device on, press reset button only one time, wait until device powers off, switch device on. Device works as it was powered off and on again. Cold Start / Initialization • • • • • Switch device on, press reset button, wait until device powers off, switch device on and press reset button once more during "For Cold Start press RESET..." is displayed (is displayed about 3 seconds), switch device on. Calling the Boot Program • • • • • • Perform a cold start (as described above), Press reset button once more within the RAM test phase. If the User Configuration was active "Saving Default Konfiguration..." is shown and the Default Configuration is activated. If the User Configuration was active "Saving User Konfiguration..." is shown and the User Configuration is activated. The device programmes the serial interface with the selected parameters, remains in the boot program and is ready to load software. The configuration for the boot program which was selected in this way is stored into Flash ROM and is conserved for a new start of the boot program. If the default configuration is active a star is displayed at the end of the boot program name. ____________________________________________________________________ aitronic 8-12 _______________________________________________________ System Functions 8.3 Battery Low Procedure In order to continue operation for a distinct time after the battery low level is reached the first time (either about 3 minutes without switching on the scanner or switching on the scanner about 25 times), the following 3-Phase-Procedure was implemented: Phase 0 Normal operation, supply volage above battery low level, internal Battery Low Counter = 0. If the battery low level is reached the first time − the message "Battery gets low, Close Operation!" is displayed, − the internal Battery Low Counter is set to 25, − a change to Phase 1 happens. Phase 1 Each 7 seconds respectively each time switching on the scanner the Battery Low Counter is incremented if the supply voltage further stays beyond the battery low level. If the Battery Low Counter reaches the value 50 "Charge Battery!!" is displayed, a change to Phase 2 happens and the device is switched off. or the Battery Low Counter is decremented if the supply voltage is above the battery low level. A change to Phase 0 happens if the Battery Low Counter reaches the value 0. Phase 2 Each 7 seconds respectively each time switching on the scanner the Battery Low Counter is decremented if the supply voltage is above the battery low level. A change to Phase 0 happens if the Battery Low Counter reaches the value 0. or if the supply voltage one more time reaches the battery low level the Battery Low Counter is set to the value 565, "Charge Battery!!" is displayed and the device is switched off. aitronic ____________________________________________________________________ System Functions _________________________________________________________ 8-13 8.4 Menu System The menu system consists of 4 singel menus and has the following structure: 1 APPLICATION Not available! DATA Data Data Del. MEMORY Records Mem./Byte Data Mem. COMMUNICATION SIO Parameter Hndshk/Prot. Timeouts PROT/AutoLogin PROT.-Monitor DECT Functions DECT-IPUI DECT-RFPI DECT-RSS/RLQ DECT-Cfg.prog. DECT-Cfg.snd. LAP Monitor DECT-SubsOnAir SETUP SW-Version Seriennr. Datum/Uhrzeit Password Initialisieren In case of an entered password the menu items marked grey can be executed only by entering this password. Calling/leaving the Menu System Devices with numerical Keyboards The menu system is called with key * and also left in this way. Calling the menu system is only possible in case of empty entry mask. When entering the menu system the menu item which was selected when leaving the menu system the last time is displayed. Devices with alphanumerical Keyboards Press key MENU instead of key *. Selecting Menus Selecting the next menu is done by holding down key SHIFT and pressing key. Leaving menu 4 menu 1 is selected. Selecting the previous menu is done by holding down key SHIFT and pressing key. Leaving menu 1 menu 4 is selected. In each menu the last menu item keeps selected. The desired menu can also be selected directly by holding down key SHIFT and pressing key 1…4. ____________________________________________________________________ aitronic 8-14 _______________________________________________________ System Functions Selecting Menu Functions The next menu item is selected with key . Leaving the last menu item the first menu item of the next menu is selected. The previous menu item is selected with key . Leaving the first menu item the last menu item of the previous menu is selected. The desired menu item can also be selected directly with keys 1...9. If the desired menu item is not available the last menu item of the actual menu is selected. Executing Menu Functions The actual menu function is executed with key +. Returning to Menu System After execution of menu functions which don't leave the menu system respectively which lead to other display outputs an exit from the the menu system can be performed by • pressing key +, C (only if this key isn't used for other functions) or SHIFT C when using devices with numerical keyboard. • pressing key +, CLR (only if this key isn't used for other functions) or DEL when using devices with alphanumerical keyboard. Menü: 1 APPLICATION Not available! This menu is normally not available. But it may be configured by means of PC programs MTWIN 2.0 whereby all of the system menu functions can be used (refer to TECHNICAL MANUAL). aitronic ____________________________________________________________________ System Functions _________________________________________________________ 8-15 Menü: 2 DATA MEMORY 1 Data Records Displaying the amount fo stored and deleted records. The appropriate function keys return back to the menu system. 2 Data Mem./Byte Displaying the amount of occupied and free data memory in byte. The appropriate function keys return back to the menu system. 3 Del. Data Mem. After confirming the question "Delete Data Memory?" with function key + the data memory is deleted and the first input mask of the selected program is displayed. Any other key returns back to the menu system. Menü: 3 COMMUNICATION 1 SIO Parameter Displaying the adjusted baudrate and parity bit. The appropriate function keys return back to the menu system. 2 Hndshk/Prot. Displaying the adjusted SIO handshake respectively protocol. The appropriate function keys return back to the menu system. 3 Timeouts Displaying the adjusted timeout(s) depending on the SIO handshake respectively protocol. The appropriate function keys return back to the menu system. 4 DECT Functions Calling sub menu ‚DECT Functions’. ____________________________________________________________________ aitronic 8-16 _______________________________________________________ System Functions Sub-Menü: 3 DECT Functions 1 DECT-IPUI Displaying the IPUI (International Portable User Identification) of the integrated DECT module. 2 DECT-RFPI Displaying the 6 entered RFPI (Radio Fixed Part Identification) of the integrated DECT module, as well as the status (0=inactive, 1=active) right below on the LCD. The base stations RFPI, to which an active connection existst, is marked with *. When pressing key ENTER the next RFPI will be displayed. After pressing key C resp. CLR the actual entry may be modified. With SHIFT C resp. DEL the function will be leaved. 3 DECT-RSS/RLQ Displaying the Radio Signal Strength and the Radio Link Quality of the active DECT connection. This function may be used to „measure out“ the area in which the DECT communication should take place ,. 4 DECT-Cfg.prog. Programming the loaded Konfiguration into the DECT module. 5 DECT-Cfg.snd. Sending the loaded DECT module configuration via the serial interface. 6 LAP Monitor Displaying the amount of the sent/received LAP-EC protocol data blocks as well as the repeated data blocks. 7 DECT-SubsOnAir Calliing the DECT Subscription on Air procedure. With this procedure a connection to next reachable base station which RFPI is entered and activated will be established automatical. aitronic ____________________________________________________________________ System Functions _________________________________________________________ 8-17 Menü: 4 SETUP 1 SW Version Displaying the device information on the LCD. The device information consists of three displays and is scrolled forward by function key +. With devices missing a keyboard the scrolling happens automatical. 2 Serial Number Displaying the 6 digit serial number which is permanently stored in FlashROM. The appropriate function keys return back to the menu system. 3 Date/Time Conitinous displaying of date and time. By pressing key C (respectively pressing key CLR when using devices with alphanumerical keyboard) date/time can be modified. The appropriate function keys return back to the menu system. 4 Password Displaying the password. By pressing key C (respectively pressing key CLR when using devices with alphanumerical keyboard) the password can be modified. To confirm this input the password must be entered a second time. The appropriate function keys return back to the menu system. 5 Initialize After confirming the question "Exec. Boot Prog/Initialize?" with key + the boot program is called (→ software update). Any other key returns back to the menu system. This command can only be executed in case of empty or transmitted data memory. After calling the boot program initialization of the device takes place (→ cold start) even if there was no software update loaded. ____________________________________________________________________ aitronic 8-18 _______________________________________________________ System Functions 8.5 Function Barcodes Commands Show Software Version Öü$I5ä Displaying the device information. With a PMS scrolling can be stopped with the scanner switch. Transmit Data Öü$D&ä Transmits data via the serial interface (as SIO command D). Set Data Transmission Lock Öü$F1pä Setting the Data Transmission Lock (as SIO com-mand T1). Reset Data Transmission Lock Öü$F0lä Resetting the Data Transmission Lock (as SIO command T0). Enable Function Barcodes _____________________________________________ Öü$X1?ä aitronic ____________________________________________________________________ System Functions _________________________________________________________ 8-19 Program Selection The selection of another program is only allowed in case of empty data memory! The selection of application programs 1 - 10 requires a special application pro-gram which provides this function. Standard Program 1 Article Number/Quantity Standard Program 2 Article Number Öü$A0]ä Öü$AA:ä Appl.-Prog. 1 Appl.-Prog. 6 Öü$A1aä Öü$A6uä Appl.-Prog. 2 Appl.-Prog.7 Öü$A2eä Öü$A7yä Appl.-Prog. 3 Appl.-Prog. 8 Öü$A3iä Öü$A8}ä Appl.-Prog. 4 Appl.-Prog. 9 Öü$A4mä Öü$A9ä Appl.-Prog. 5 Appl.-Prog. 10 Öü$A5qä Öü$A:…ä ____________________________________________________________________ aitronic 8-20 _______________________________________________________ System Functions Standard Barcode Menu Öüö1Lä Öü$Zhä Öüö2Oä Öü$KAXä Öüö3Rä Öü$KEhä Öüö4Uä Öü$KUAä Öüö5Xä Öü$KIxä SHIFT SHIFT Öüö6[ä Öüö7^ä Öüö8aä Öü$H2ä Öüö9dä Öü%A†ä Öüö0Iä Öü$MAä SHIFT C aitronic ____________________________________________________________________ System Functions _________________________________________________________ 8-21 Function Keys Öü$0Qä Öü$5`ä Öü$1Tä Öü$6cä Öü$2Wä Öü$7fä Öü$3Zä Öü$8iä Öü$4]ä Öü$9lä SHIFT 0 SHIFT 1 SHIFT 2 SHIFT 3 SHIFT 4 SHIFT 5 SHIFT 6 SHIFT 7 SHIFT 8 SHIFT 9 ____________________________________________________________________ aitronic 8-22 _______________________________________________________ System Functions Alpha Characters Öüö032!ä Öüö042%ä Öüö033&ä Öüö043*ä Öüö034+ä Öüö044/ä Öüö0350ä Öüö0454ä Öüö0365ä Öüö0469ä Öüö037:ä Öüö047>ä Öüö038?ä Öüö058Gä Öüö039Dä Öüö059Lä Öüö040‚ä Öüö060#ä Öüö041öä Öüö061(ä Space aitronic ____________________________________________________________________ System Functions _________________________________________________________ 8-23 Öüö062-ä Öüö0736ä Öüö0632ä Öüö074;ä Öüö0647ä Öüö075@ä Öüö065<ä Öüö076Eä Öüö066Aä Öüö077Jä Öüö067Fä Öüö078Oä Öüö068Kä Öüö079Tä Öüö069Pä Öüö080+ä Öüö070'ä Öüö0810ä Öüö071,ä Öüö0825ä Öüö0721ä Öüö083:ä ____________________________________________________________________ aitronic 8-24 _______________________________________________________ System Functions Öüö084?ä Öüö095Hä Öüö085Dä Öüö096Mä Öüö086Iä Öüö097Rä Öüö087Nä Öüö098Wä Öüö088Sä Öüö099\ä Öüö089Xä Öüö100uä Öüö090/ä Öüö101zä Öüö0914ä Öüö102üä Öüö0929ä Öüö103„ä Öüö093>ä Öüö104"ä Öüö094Cä Öüö105'ä aitronic ____________________________________________________________________ System Functions _________________________________________________________ 8-25 Öüö106,ä Öüö1175ä Öüö1071ä Öüö118:ä Öüö1086ä Öüö119?ä Öüö109;ä Öüö120}ä Öüö110yä Öüö121‚ä Öüö111~ä Öüö122öä Öüö112ƒä Öüö123%ä Öüö113!ä Öüö124*ä Öüö114&ä Öüö125/ä Öüö115+ä Öüö1264ä Öüö1160ä ____________________________________________________________________ aitronic 8-26 _______________________________________________________ System Functions 8.6 Charging the integrated Accumulators The integrated accus should be charged periodical (in case of intensive usage at least once a day). If the accu capacity runs empty because the accus were not charged the device displays the message "Battery gets low, Close Operation!". After this message about 25 barcodes can be still read respectively the device can be operated with still for about 3 minutes. Then the device displays the message "Charge Battery!!!" and switches off automatical. Detailed informationen concerning special charging devices refer to the TECHNICAL MANUAL FOR MOBILE TERMINALS OF PMS, HTE AND MOBISCAN SERIES. aitronic ____________________________________________________________________ System Functions _________________________________________________________ 8-27 8.7 Error Messages Error Message Battery gets low Close Operation! Charge Battery!!! BP: MTBOT vvv Err nn, load SW! Description Cause respectively Help The current procedure should The accus only contain a remaining capacity. The first be closed and the MT should time this message is be connected to mains by displayed with a 5 seconds means of the long pulsing beep sequence. Charging/Transmission Adpater Within this duration the Goodbecause after this error Read-LED is switched on. message only about 25 During the following operation barcodes can be scanned this message is displayed respectively there is only a with a shorter beep sequence remainding operation time of every 7 seconds respectively about 3 minutes before the after each scan. device displays the error message "Charge Battery" and then powers off. The accus doesn't supply the required voltage. Connect MT with Charging/Transmission Adapter to mains. An error was detected during Flash-ROM-Check. The error code nn contains the number(s) of the erroneous banks (bitmapped). Perhaps a software update was broken or a Software Module is missing. Help: Execute software update once more. In case of error code Bit 4 = 1 a boot program checksum error was detected. In this case the boot program must be loaded once more. BP Version < 5.0 required! An attempt was made to load an operating system version < 5.0. At first load the required boot program version, then repeat the operating system software update.. Data Memory contains Data! A function that requires the data memory cannot be executed because data are stored. Transmit data and execute desired function once again. Data Memory full! Data memory is full. Transmit data and delete data memory. Error Message Description Cause respectively Help ____________________________________________________________________ aitronic 8-28 _______________________________________________________ System Functions Receive Timeout! When receiving data (i.e. software update) there was a delay longer than Rx Timeout (configruation parameter). Check Computer and Charging/Transmission Adapter. Perhaps enlarge Rx Timeout (configruation parameter). Execute desired function once again. Function not implemented! Selected function is not implemented in used device type. Selected function cannot be executed (i.e. switching LCD ilumination on/off with PMS 1200). Handshake Timeout! The RS-232 Handshake (XON/XOFF respectively RTS/CTS) was missing for a duration longer than programmed under HndShk Timeout (configuration parameter). The connected computer (application) is not active anymore, doesn't handle the handshake correct, produces to long time delays or the Charging/Transmission-Adapter is erroneous. Try to enlarge HndShk Timeout (configuration parameter). Invalid AP Version! An attempt was made to load an application which was compiled for another operating system version. At first load the required operating system version, then repeat the loading of the application. Invalid DS Version! An attempt was made to load a Decoding Software version which was compiled for another operating system version. At first load the required operating system version, then repeat the loading of the Decoding Software . No connection! Missing RS-232 signal CTS. The connected computer (application) is not active anymore or the Charging/ Transmission Adapter is erroneous. Mask Buffer Overflow! The mask buffer got overflowed. Error in the application program. When buffering input masks there must also be precautions of removing mask numbers from the mask buffer again. Error Message Description Cause respectively Help aitronic ____________________________________________________________________ System Functions _________________________________________________________ 8-29 Not possible with S/N:000000! The device resides in Test Mode (serial no. '000000' ). The executed function requires a serial no. different from '000000' (i.e. LAP-EC). Program serial no. and execute desired function once more. No OS loaded! An attempt was made to start a non existing operating system. Load operating system and application. Par.Overr.Fram. Error! A character with erroneous parity or stop bit was received via the serial interface. Check SIO parameter and set it to the correct values. Start aborted procedure once more. Protocol abort! S-File Checksum Error! S-File Format Error! Transmission Timeout! XModem or LSV-2 protocol was aborted. Start aborted procedure once more. Error in S-File-Checksum detected. Check S-File and execute software update once more. Erroneous S-File fomat. Check S-File and execute software update once more. While communicating via LAP-EC the transmission buffer was full for a duration longer than the time defined by Tx Timeout/LAP-EC (configuration parameter). The application which communicates with MT produces to long time delays while receiving data. Try to enlarge Tx Timeout/ LAP-EC (configuration parameter) or solve the problem in the application. LAP-EC: Blkcnt Error, press + Fatal error while communicating via LAP-EC in the operating system. The MT must be manual (menu function) logged in again. Start PC software again. The block counters will be resetted in that way. LAP-EC: Block Counter Error! Fatal error while communicating via LAP-EC in the boot program. Perform cold start of the MT. Start PC software again. The block counters will be resetted in that way. LAP-EC: No Communikation! RF net not active respectively MT resides outside of the RF area. Refer to explanation (1). Check NARF and RF module of MT and start PC software respectively return with MT back to the active RF area. LAP-EC not active! Selected function requires LAP-EC. Activate LAP-EC and execute desired function once more. ____________________________________________________________________ aitronic 8-30 _______________________________________________________ System Functions Error Message Description Cause respectively Help LAP-EC: Not logged in! MT not logged in. Refer to explanation (1). Check initialization file on the PC and start PC software again, the RF Scanner will be logged in again. Line Buffer Overflow! The line buffer for the serial interface has got overflowed because there were more than 255 charcters received without a CR. The application which communicates with MT sends more than 255 characters without a CR. Explanations (1) These error messages are not displayed with the Standard Program but can be activated in a special application by means of the corresponding configuration parameter. aitronic ____________________________________________________________________ System Functions _________________________________________________________ 8-31 8.8 Error Diagnostics The following table should help with errors that are not indicated by an error message but appearing as unexpected behaviour of the MT. Symptom Barcodes are read badly Cause respectively Help • • • Screen at the front of the device (PMS) has become dirty or scratched, Barcode printed badly, dirty or scratched. Too much barcode types activated. Activate only those barcode types which are required. Serial communication is erroneous Serial interface parameters (baudrate, parity at MT or PC side or both) are not selected correct . Serial communication doesn't work at all With Charging/Communication Adapter (RS-232) • Charging/Transmission Adapter not connected to mains, • Connector of Charging/Transmission Adapter not connected completely to the device, • Charging/Transmission Adapter not connected correctely to the PC, • Serial interface of MT or PC erroneous. With Infrared Cradle • Device not pushed completely into the Cradle, • Cradle not connected correctely to the PC, • Infrared interface of MT or Cradle dirty or erroneous, • Serial interface of the PCs erroneous. With RF or RS-485-Cradle or INAP and LAP-EC • NARF respectively. NAC not switched on or not connected correctly, • LAP-EC and/or concerning application on PC not active, • Device is not logged in (at the right bottom of LCD only the symbol o is shown), • Device resides outside the RF area (at the right bottom of LCD neither o nor * is shown), ____________________________________________________________________ aitronic 9-2 _________________________________________________________ Software Update For a software update the following steps must be performed: • Connect device via charging/transmission-adapter to the desired COM to the PC. • Start program MTCON on the PC. • If COM2 should be used this must be selected under Options/Serial Interfaces. • Read the two following function barcodes: • • • Enable Function Codes Load default Configuration Öü$X1?ä Öüö*/öööösä Load desired S-File with function Functions/Software Update/S-File. If the required boot program version isn't already loaded (refer to table on previous page) load boot program MTBOT.S with function Functions/Soft-ware Update/S-File. When the boot program prompts ready load standard software MTSTDxxx.S with function Functions/Soft-ware Update/S-File. Although the standard software MTSTD is configurable concerning hard- and software (exception: MTSTD can't be configured for the PSC Scanner with serial LCD interface, with this device the special S-File must be loaded) for the different device and communication types S-files are available. The nomenclature of the Sfiles conforms to the following sheme: MTSTDgp.S SIO Protocol no SIO Protocol, LAP-EC/RF, LAP-EC/RS-485-Cradle, LAP-EC/INAP. Device Type PMS 1200, PMS 1500 and hardware compatible devices, PSC Scanner with serial LCD interface. The underline '_' is only used if there are more parameters different from the underline before the file extension. aitronic ____________________________________________________________________ Software Update__________________________________________________________ 9-3 Examples: MTSTD.S Standard Software for PMS 1200/1500 and compatible devices without SIO Protocol for software update with MTCON or terminal emulation program. MTSTD_G.S Standard-Software für PMS 1200/1500 and compatible devices for connection to a RS485-Network. A software update must be performed with MTCON or a terminal emulation program. The boot program (from v4.4) runs the software update with the actual parameters (SIO parameter, protocol), so that it is possible to load software update via LAP-EC. When the boot program is called it stores the actual parameters in Flash-ROM, so that even after breaking off a software update a new run with these parameters is possible. If it is not possible to run the software update with the actual parameters the boot program can be set to the standard parameters if the reset button is pressed during the RAM test after cold start. ____________________________________________________________________ aitronic Technical Data ___________________________________________________________ 10-1 10. Technical Data Mobile Terminals PMS 1200/1500 Keyboard [Rows x Columns] LC Display [Lines x Character] Data Memory (RAM) Program Memory (Flash ROM) Serial Interface Real Time Clock Power Supply Audio Signal Barcode Formats Parametrization Programming Measures LxBxH [mm] Weight Environmental Temperature. Storing Relative Humidity PMS 1200 PMS 1500 4x4 2x16 with background illumination 128 K 512 K 128 K for System Software and Application Program RS-232, 300 - 19200 Bd RS-485, 300 - 19200 Bd Face-to-Face Infrared with IR Cradle, 300 - 9600 Bd connectable RF transceiver module, carrier frequency 433 or 434 MHz, active area up to 200 m (depending on environment), 4800 Bd, weight 50 g, length 60 mm day of week, date and time with seconds resolution 5 NiCd cells 1.2 V, 600 mAH, quick chargable beeper, configurable volume EAN/UPC, CODE 39, CODE 128, Code 2 of 5 int/std/matrix, Codabar, CODE 93, Code 11 with barcode menu or PC software MTWIN (v2.0 and higher). free application programming with C Development Tool MTC 100x70x170 100x70x185 340 g 400 g 5 - 50º C -40 - 70º C 5 - 95%, not condensing ____________________________________________________________________ aitronic 10-2 __________________________________________________________ Technical Data Mobile Terminals HTE 1800/1900 and MobiScan-6x/8x HTE 1800 Keyboard [Rows x Columns] LC Display [Lines x Character] Data Memory (RAM) Program Memory (Flash-ROM) Serial Interface Real Time Clock Power Supply Audio Signal Barcode Formats Parametrization Programming Measures LxBxH [mm] Weight Environmental Temperature. Storing Relative Humidity Housing Material Protection Class HTE 1900 MobiScan-6x 7x4 + 2 2x16 without background illumination 4x20 with background illumination 128 K 512 K 2x16 with background illumin. 128 K for System Software and Application Program RS-232, 300 - 19200 Bd RS-485, 300 - 19200 Bd Infrared up to a distance to about 50 cm with INAP, 19200 Bd Only HTE 1900 with NiMH-Accus: RF transceiver module, carrier frequency 433 or 434 MHz, active area up to 200 m (depending on environment), 4800 Bd. day of week, date and time with seconds resolution 3 NiMH cells 1.2 V, 580 mAH, quick chargable changable 9 V block battery beeper, configurable volume EAN/UPC, CODE 39, CODE 128, Code 2 aus 5 int/std/matrix, Codabar, CODE 93, Code 11 with barcode menu or PC software MTWIN (v2.0 and higher). free application programming with C Development Tool MTC 156x76x35 156x76x160 220x60x35 295 g 380 g 5 - 50º C 450 g -40 - 70º C 5 - 95%, not condensing ABS no restriction Aluminium IP 65 aitronic ____________________________________________________________________ Technical Data ___________________________________________________________ 10-3 Scanner Modules Mobile Terminals Resolution 5,0 mil/0,13 mm 6,0 mil/0,15 mm 7,5 mil/0,19 mm 10 mil/0,25 mm 100% UPC 20 mil/0,51 mm 30 mil/0,76 mm 40 mil/1,02 mm 55 mil/1,40 mm Scan Distance Laser Power Printing Contrast Scan Rate Scan Angle max. Pitch max. Scew Laser Diode Wave Lenght Sun Light Halogen Light Flourec. Light PSC1) Standard Optic Symbol SE 900 PMS 1200/1500 HTE 1800/1900 Symbol SE 923 HTE 1800/1900, MobiScan-6x/8x Depth of Field 5,7 - 6,4 cm 5,7 - 6,4 cm 4,5 - 15 cm 4,1 - 18 cm 4,7 - 25 cm 0 - 16 cm 4,5 - 15 cm 4,1 - 18 cm 4,7 - 25 cm 0 - 16 cm 0 - 51 cm 0 - 64 cm 0 - 51 cm 0 - 64 cm 0,94 mW ±0,06 mW min. 20 % 36 (±3) Scans/s bis 60º ±60º ±65º 650 nm 0,94 mW ±0,06 mW min. 20 % 36 (±3) Scans/s bis 60º ±60º ±65º 650 nm 8 - 13 cm 5 - 20 cm 2.5 - 25 cm 0 - 36 cm 13 - 76 cm min. 50 % 35 Scans/s ±55º ±65º 670 nm Immunity against environmental light 107640 Lux 4844 Lux 107640 Lux 4844 Lux 1) The technical data of the other types are contained in the appropriate PSC data sheets. 2) The laser beam of this module can picture a narrow ellipses instead of a horizontal line. There can also be a picture of a small dot near the laser beam line. These phenomens don't prejudice the scanning performance at all. ____________________________________________________________________ aitronic Accessories _____________________________________________________________ 11-1 11. Accessories Protection cap for PMS Rubber protection cap to soften beats onto the PMS Belt Holster for MobiScan 6x The belt holster made of leather makes it possible carrying the MobiScan at the belt, i.e. when both hands must be free for working. Redirection Optic for HTE The mirror optic for the laser scanner makes it possible to scan horziontal oriented barcodes in an ergonomic way (i.e. out of order lists). ____________________________________________________________________ aitronic 11-2 ____________________________________________________________ Accessories RS-232 Cable for HTE and MobiScan Steckverbindung: zum Scanner: HCL Interconnectron zum Computer: SubD 9 pol. 2-Bay Charging Cradle for HTE 1900 Fast Charging Cradle for HTE 1900 Max. charging time 1,5 h Interface: RS-232, RS-485, LAN (Ethernet) Cradle MobiScan 6x PTR Communication/Charging Cradle for MobiScan 6x Max. charging time 1,5 h Interface: RS-232, LAN (Ethernet) aitronic ____________________________________________________________________ Accessories _____________________________________________________________ 11-3 2-Bay Cradle MobiScan 6x/8x UDS Charging Cradle with two UDS connectors Charging Time: 1,5 h Interface: RS-232, RS-485, LAN (Ethernet) 1-Bay Cradle UDS with RS-232 and LAN Interface Charging Cradle with UDS connector Charging Time: 1,5 h Interface: RS-232, LAN (Ethernet) Cradle 1-fach UDS Charging Cradle with UDS connectors Charging Time: 1,5 h Accesspoint for DECT RF Network ____________________________________________________________________ aitronic 11-4 ____________________________________________________________ Accessories RF Module: Interfaces: MD-32 RS-232, LAN Connection up to 16 mobile terminals per each Accesspoint possible aitronic ____________________________________________________________________ Recycling Orders _________________________________________________________ 12-1 12. Recycling Orders Battery Order Following the 'Verordnung über die Rücknahme und Entsorgung gebrauchter Batterien und Akkumulatoren’ (shortcut: Batterieverordnung - BattV) BGBl I page 658 from 27.3.1998 manufacturers and distributors only may put batteries and accumulators containing poisonous material into circulation if they ensure that the consumer may return it back after usage. This Battery Order is also valid for salvage devices which contain fixed installed batteries and accumulators. In the same manner the consumer is bound to recycle used batteries and accumulators following this Battery Order. The complete (german) Battery Order may be inspected under Internet address http://www.umweltrecht.de/recht/abfall/bat.htm Our home page contains a corresponding link. Therefore we offer a feeless returning back service (free to the door) for used batteries and accumulators coming from our devices and also for complete salvage devices coming from us which contain fixed installed batteries and accumulators to our clients. IT Salvage Devices Order At the time this manual was printed only a draft of the ‘Verordnung über die Entsorgung von Geräten der Informations-, Büro- und Kommunikationstechnik’ (ITAltgeräte-Verordnung - ITV) which was passed from the Bundeskabinett at 19.5.1998. Following this draft manufacturers and importers must take back salvage IT devices to recycle it. The draft of the IT Salvage Devices Order may be inspected under Internet address http://www.nordschwarzwald.ihk.de/umwelt/un-na2-98.htm Our home page contains a corresponding link. We offer to our clients already now a feeless returning back service (free to the door) for salvage devices which come from our production. ____________________________________________________________________ aitronic Additional Manuals ________________________________________________________ 13-1 13. Additional ManualsECHNICAL MANUAL for Mobile Terminals of PMS, HTE, and MobiScan Series, Single Connection Components, Network Components and Accu Charging Devices Manual for device administrators and service purposes. APPLICATION PROGRAMMING MANUAL for Mobile Terminals of PMS, HTE, and MobiScan Series This manual is included in the standard delivery package of MTC (C-DevelopmentKit for MTs) and deals as a reference for MT application programmer. CONNECTIVITY & APPLICATIONS with Mobile Terminals of PMS, HTE, and MobiScan Series, Single Connection Components, Network Components and Accu Charging Devices This manual contains an overview about Mobile Terminals of PMS, HTE and MobiScan Series, about the single connection components Communication/ Charging Adapter and IR Cradle, about network components NAC, NARF, IR Cradle, INAP, NA-485 and about accu charging devices and shows the application of these devices. Another chapter contains applications examples. WINDECT FileExchLib, ODBCLib, COMLib, PortServ Windows-Software-Paket für den Betrieb eines DECTFunknetzwerkes mit den mobilen Terminals der PMS-, HTE-, MobiScan- und PocketScan-Reihe This manual documents the functionality and parametrization of the WinDECT Software. DECT RF NETWORK Concept & Installation for mobile Terminals of PMS, HTE, MobiScan and PocketScan Family This manual introduces the concept of the RF Networ and contains instructions for the installation of it. ____________________________________________________________________ aitronic Standard Program MTSTD__________________________________________________ 14-1 14. Standard Program MTSTD Initialization following Cold Start After the device performed cold start datum and time will be displayed: Date ww tt.mm.jj Time hh:mm:ss With key + resp. ENTER datum/time can be overtaken. Changing date/time can be done by pressing key C (devices with numerical keyboard) resp. CLR (devices with alphanumerical keyboard). After entering date/time a password map be entered. Set Password _______________ Entry is optional an may be stepped over with + resp. ENTER. An entered password must be confirmed : Confirm Password _______________ After confirming the entered password the entry mask for data capturing will be shown. ____________________________________________________________________ aitronic 14-2 _________________________________________________ Standard Program MTSTD Data Capturing After entering date/time and password the Standard Program mask is shown. Standard Program 2 deals to capture article numbers and quantities. ________________ _______ _______ When the cursor resides in the empty article number field an article number can be read by pressing the trigger switch. The scanned article number is shown on the LCD with quantity "1". The symbol ∗ at the last position on the LCD shows that an article number was scanned just now. When pressing the trigger switch or any key again this symbol vanishes. The cursor resides under the "1" in the quantity field, so that this could be overwritten by the following entry. The record may be stored into data memory by pressing key + or by the scanning the next article number. Standard Programm 2 deals to capture article numbers. ________________ _______________ When the article number field ist empty an article number can be scanned. The scanned article number will be shown on the LCD an is stored into data memory. The article number keeps staying on the display, the cursor is switched off and symbol ∗ at the last position on the LCD shows that an article number was scanned just now. By pressing the trigger switch the next time the empty input mask with the cursor at the first position is shown again. The keys 0...9 deal for manually data entry. In case of devices with numerical keyboard the entry of alphanumerical characters can be done by entering the decimal ASCII Code by means of the SHIFT key or with the Standard Barcode Menu. aitronic ____________________________________________________________________ Standard Program MTSTD__________________________________________________ 14-3 Displaying Records With the keys and record by record can be scanned forward and backward through data memory. By holding down key SHIFT and pressing key Taste ora jump to the beginning respectively to the end of data can be performed. In case of devices with alphanumerical keyboard key ormust pressed before this function can be executed. The selected record ist shown and the cursro is switched off. When the trigger switch or any key is pressed the actual input mask is shown again.. Modifying/deleting/undeleting a Record Devices with numerical Keyboard The actual input mask must be empty for this functions. Display the record you want to change, delete or undelete (as described in previous section). Press key SHIFT and hold it down. Press key C as often until the desired function: "Change Record?", "Delete Record?" or "Undelete Record?" is displayed in line 2 of the LCD. Release both keys. If you now confirm with key +, the displayed function is executed. Each other key breaks the function. Deleted records are displayed with the symbol # at the last cursor position of the LCD. Geräte with alphanumerical Keyboard Press key DEL instead of keys SHFIT C. By pressing key + the displayed function will be performed. Each other key lead to cancelling the function. Deleted records are shown with symbol # at the last LCD position, in case of selected configuration parameter Show deleted Record. Function Keys Functions are performed by holding down key SHIFT and pressing the appropriate key 0 to 9. ____________________________________________________________________ aitronic 14-4 _________________________________________________ Standard Program MTSTD Data Transmission Data transmission can be done with MTWIN or a client specific application. With Charging/Communication Adapter or Infrared Cradle (offline) Connect the charging/communication adapter or the infrared cradle to the appropriate interface (default for MTWIN is COM1) of the PC and start MTWIN on the PC. With RS-485 Cradle or LAP-EC (offline) Connect the RS-485-Cradle (resp. the RS-485 network) to the appropriate interface (COM1 or COM2) of the PC and start PRONET on the PC. With RF Modue and LAP-EC (online) Connect the RF base station (accesspoint) to the appropriate interface (COM1 or COM2) of the PC and start PRONET on the PC (refer to PRONET MANUAL). With Charging/Communication Adapter (RS-232) or Infrared Cradle The data transmission may be performed in several ways: • Manual data transmission with the appropriate function codes or the appropriate menu function. • Calling the data via the serial interface from PC program MTWIN or from a client specific application. • In case of configuration parameter Start Data Transmission: PowerOn+ CTS or SIO Command set after switching on the terminal via interface line DTR "Ready for Data Transmission" will be show on the LCD. At the beginning of data transmission "Data Transmission active..." will be shown an the captured data are transmitted.The end of data transmission will be shown with "Data Transmission completed" angezeigt. If the terminal is connected to the serial interface during data capturing and therefor switched on all the time, the captured data may be called using the appropriate SIO command. ATTENTION: In case of infrared data transmission a finally error rate can’t be prevented (below 1 promille). Therefor when using an infrared cradle the XModemprotocol muss be used for data transmission! aitronic ____________________________________________________________________ Standard Program MTSTD__________________________________________________ 14-5 With RF Communication or RS-485 Network and LAP-EC In case of active LAP-EC the captured data are first stored in data memory. The data transmission is then performed in background to the PC. An established data connection between terminal and PC is required. This data connection is active when the terminal is logged in and right below on the LCD the symbol o is shown. When using an RS-485 cradle the terminal must be put into the cradle. After the data transmission is successful performed the data transmission lock should be set by SIO command T1 ("Data transmitted" will be shown). In this condition the data memory may be cleared by SIO command CLRMEM or by holding down key SHIFT and pressing key C (resp. key DEL in case of alphanumerical keyboard). The transmitted data have the following format: %%STX-ssssss/rrrrr/tt.mm.jjjj/hh:mm:ss%%ETX-cccc rrrrr ssssss tt.mm.jjjj hh:mm:ss cccc Amount of the following data records, Devices serial number (refer to data plate), Date of data transmission, Time of data transmission, 16-Bit checksum in hex format. The checksum is calculated starting with "%STX" up to "%%ETX-" included by adding all printable ASCII characters (hex codes $20 up to $7E included). ____________________________________________________________________ aitronic 14-6 _________________________________________________ Standard Program MTSTD Erasing the Data Memory To clear the data memory manually the "Data transmitted". Condition is required. This condition is reached after a succesful data transmission and/or by setting the data transmission lock by SIO command T1. Devices with numerical Keyboard By holding down key SHIFT and pressing key C "Delete Data Memory?" will be shown. After confirming with key + data memory will be cleared. All other key will cancel this function. Devices with alphanumerical Keyboard Press key DEL instead of key SHIFT C. aitronic ____________________________________________________________________ Standard Program MTSTD__________________________________________________ 14-7 Test Barcodes Code 39 *CODE-39P* CODE-39 *01234A* 01234 __________________________________________________________________________ UPC 1 2 __________________________________________________________________________ EAN 2 __________________________________________________________________________ Code 2/5 int. ÄNdz&ä 4567890 Ä!-8CNYdpä 01223344556677 ____________________________________________________________________ aitronic 14-8 _________________________________________________ Standard Program MTSTD Code 2/5 std. <01236> 0123 <1234565> 123456 __________________________________________________________________________ Code 128 ÖCode-128:ä Code-128 Öabc-ABC-123_ä abc-ABC-123 aitronic ____________________________________________________________________
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2005:01:19 16:08:37Z Modify Date : 2005:01:19 17:10:42+01:00 Page Count : 63 Creation Date : 2005:01:19 16:08:37Z Mod Date : 2005:01:19 17:10:42+01:00 Producer : Acrobat Distiller 5.0 (Windows) Author : FKP Metadata Date : 2005:01:19 17:10:42+01:00 Creator : FKP Title : Microsoft Word - Operating Manual PMS, HTE und MobiScan v6, english.doc Has XFA : NoEXIF Metadata provided by EXIF.tools