Data sheet DS/WM–EN Rev. U
WaterMaster
Electromagnetic flowmeter
Measurement made easy
The perfect fit for all water
industry applications
One solution for all your needs
designed for use in all water and waste water applications,
from sewage plants to distribution networks
State-of-the-art technology
revolutionary data storage enables transmitter interchange
and commissioning without the need for re-configuration
self-calibrating transmitter with ultra-low temperature
coefficient for highest accuracy
Versatile and simple configuration
'Through-the-Glass' (TTG) configuration eliminating the
need to remove the cover
smart key based functionality
'Easy Setup' function
VeriMaster in situ verification software option
enables the customer to perform in situ verification of the
flowmeter system
Unparalleled service ability
fault-finding Help texts on the display
minimized downtime with replaceable electronics cartridges
MID and OIML R49 approved with R49 self-checking
— Type-approved to accuracy Class 1 and Class 2 for any pipe
orientation and bidirectional flows
Type P-approved continuous self-checking of the sensor
and transmitter to ensure the highest accuracy and long
term performance
Innovative sensors for all applications
optimized full-bore series for optimum turndown / low
pressure drop, irrigation applications
full-bore series for general-purpose water metering
applications
reduced-bore series for high turn down applications, for
example, leakage
buriable sensors eliminating the need for costly chamber
construction
HART, PROFIBUS DP and MODBUS
Full system and PLC integration
WaterMaster
Electromagnetic flowmeter
2DS/WM–EN Rev. U
The Company
ABB is an established world force in the design and
manufacture of instrumentation for industrial process control,
flow measurement, gas and liquid analysis and environmental
applications.
As a world leader in process automation technology our
worldwide presence, comprehensive service and
application-oriented know-how make ABB a leading supplier of
flow measurement products.
Introduction
Setting the standard for the Water Industry
The WaterMaster range, available in sizes 10 to 2400 mm
(3/8to 96 in.), is designed specifically for use on the many
diverse applications encountered in the Water and Waste-water
industry. The modular design concept offers flexibility,
cost-saving operation and reliability while providing a long
service life and exceptionally low maintenance.
Integration into ABB asset management systems and use of the
self-monitoring and diagnostic functions increase the plant
availability and reduce downtimes.
VeriMaster – the verification tool
An easy-to-use utility, available through the infra red service port,
it uses the advanced self-calibration and diagnostic capability of
WaterMaster, coupled with fingerprinting technology, to
determine the accuracy status of the WaterMaster flowmeter to
within ±1 % of its original factory calibration. VeriMaster also
supports printing of calibration verification records for regulatory
compliance.
Diagnostic functions
Using its diagnostic functions, the flowmeter monitors both its
own operability and the process. Limit values for the diagnostic
parameters can be set locally. When these limits are exceeded,
an alarm is tripped. In the event of an error,
diagnostic-dependent help text appears on the display and this
considerably simplifies and accelerates the troubleshooting
procedure.
In accordance with NAMUR NE107, alarms and warnings are
classified with the status of 'Maintenance Required', 'Check
Function', 'Failure' and 'Out of Specification'.
Flow performance
Utilizing its advanced filtering methods, the WaterMaster
improves accuracy even under difficult conditions. WaterMaster
has an operating flow range with ±0.4 % accuracy as standard
(±0.2 % optional) in both forward and reverse flow directions.
Easy and quick commissioning
'Fit-and-Flow' data storage inside WaterMaster eliminates the
need to match sensor and transmitter in the field. On initial
installation, the self-configuration sequence automatically
replicates into the transmitter all calibration factors, meter size
and serial numbers, as well as customer site-specific settings,
eliminating the potential for error.
Intuitive, convenient navigation
The 'Easy Setup' function reliably guides unpracticed users
through the menu step by step. The smart key based
functionality makes handling a breeze – it's just like using a cell
phone. During configuration, the permissible range of each
parameter is indicated on the display and invalid entries are
rejected.
Universal transmitter – powerful and flexible
The backlit display can be rotated easily without the need for
tools. The contrast is adjustable and the display
fully-configurable. The character size, number of lines and
display resolution (number of decimal points) can be set as
required. In multiplex mode, several different display options can
be pre-configured and invoked one after the other.
The smart modular design of the transmitter unit enables easy
disassembly without the need to unscrew cables or unplug
connectors. HART is used as the standard communications
protocol. Optionally, the transmitter is available with PROFIBUS
DP or MODBUS communication.
Assured quality
WaterMaster is designed and manufactured in accordance with
international quality procedures (ISO 9001) and all flowmeters
are calibrated on nationally-traceable calibration rigs to provide
the end-user with complete assurance of both quality and
performance of the flowmeter.
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 3
WaterMaster – always the first choice
WaterMaster sets the standard for the water industry. The
specification, features and user benefits offered by this range are
based on ABB's worldwide experience in this industry and they
are all targeted specifically to the industry's requirements.
Submersible and buriable
WaterMaster sensors have a rugged, robust construction to
ensure a long, maintenance-free life under the arduous
conditions experienced in the Water and Waste Industry. The
sensors are, as standard, inherently submersible (IP68, NEMA
6P), thus ensuring suitability for installation in chambers and
metering pits that are susceptible to flooding.
A unique feature of the WaterMaster sensors is that sizes DN40
to DN2400 (11/2to 96 in. NB) are buriable; installation simply
involves excavating to the underground pipe, fitting the sensor,
cabling back to the transmitter and then backfilling the hole.
Overview of the WaterMaster
A wide range of features and user benefits are built into
WaterMaster as standard:
bi-directional flow
unique self-calibrating transmitter (patented) for the
ultimate in stability and repeatability
OIML-type continuous self-checking, with alarms,
ensures both sensor and transmitter accuracy
true electrode and coil impedance measurement
comprehensive simulation mode
universal switch-mode power supply
(options are available for AC and DC supplies)
comprehensive self-diagnostics compliant with
NAMUR NE107
programmable multiple-alarm capability
bus options: HART (4 to 20 mA), PROFIBUS DP (RS485),
MODBUS (RS485)
3 configurable pulse / frequency and alarm outputs
advanced infrared service port supports remote HMI,
HART, cyclic data out and parameter download
VeriMaster in situ verification software available as option
read-only switch and ultra-secure service password for
total security
The WaterMaster family
WaterMaster
Electromagnetic flowmeter
4DS/WM–EN Rev. U
OIML / MID approved
WaterMaster has been type tested and Internationally approved
to the highest accuracy class 1 and 2 for cold and hot potable
water meters – OIML R49-1 (Organisation Internationale de
Métrologie Légale). For full details, OIML R49 is available to
download from www.oiml.org. Its requirements are very similar
to other International standards, such as EN14154 and
ISO4064.
WaterMaster has been assessed by type approval at the
National Measurement Office (NMO) to OIML R49 and passed
to the very highest accuracy designations for sizes DN40 to
DN200 (11/2to 8 in. NB).
The approval is for:
Class 1 and Class 2 accuracy (calibration option)
Environmental class T50 for water temperatures of
0.1 to 50 °C (32.18 to 122 °F)
Electromagnetic Environment E2 (10 V/m)
Any pipe orientation
5 Diameters upstream pipe
0 Diameters downstream pipe
Pressure Loss Class <0.25 bar (3.62 psi)
Integral or remote transmitter (<200 m [<656 ft.] cable)
DN40 to DN200 (11/2to 8 in. NB), bi-directional flow
A major advance in WaterMaster is the self-checking capabilities
that meet and exceed the R49 requirements and is the first
electromagnetic flowmeter to be approved to OIML Type P
permanent self checking during normal operation (not just at
startup) and alarm indication for:
transmitter and sensor status, with an accuracy alarm
program ROM and RAM status
double, independent storage of totalizer values, in both
the sensor and transmitter non-volatile memories
display test
The OIML R49-1 certificate of conformity is available from:
http://www.abb.com/product/seitp330/b42ec2377d3293cd
c12573de003db93b.aspx
WaterMaster is also approved under the EU Measuring
Instruments Directive (MID) 2004/22/EC, that covers putting into
use water flowmeters for certain applications. MID WaterMaster
is secured against tamping and is available as an option, along
with fingerprinting for ABB VeriMaster in situ verification product,
with certificate printout to ±1 % accuracy.
WaterMaster certificates of EC type-examination of a measuring
instrument are available from:
http://www.abb.com/product/seitp330/b42ec2377d3293cd
c12573de003db93b.aspx
Superior control through advanced sensor design
The innovative, patented octagonal sensor design improves flow
profile and reduces up- and down-stream piping requirements
for the most commonly used sizes of 40 to 200 mm (11/2to
8 in.). This optimized full bore meter provides impressive results
in the most difficult of installation requirements.
WaterMaster sensors are also available in reduced-bore
geometries giving the ultimate in low-flow performance with a
very high turn-down range.
The unique design of the reduced-bore sensor conditions the
flow profile in the measuring section so that distortions in the
flow profile, either upstream or downstream, are flattened. The
result is excellent in situ flowmeter performance, even with very
bad hydraulic installation conditions.
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 5
Specification
WaterMaster specification to OIML R49 Class 1
WaterMaster specification to OIML R49 Class 2
Although OIML R49 does not define the flow accuracy below Q1, WaterMaster continues to measure flow at lower flow rates down to
a cutoff velocity of ±5 mm/s (±0.2 in./s). The accuracy between cutoff and Q1 is typically ±0.9 mm/s (±0.04. in./s).
0.1 (0.44) 1.0 (4.4) 10 (44) 100 (440) 1000 (4402)
WaterMaster Class 1
Specification
OIML R49 Class 1
Accuracy Limits
Typical Meter
Performance
±0.2 % ±0.9 mm/s
whichever is the greater
Around Q2 the
performance is
±0.7 mm/s
Flowrate m3/h (GPM)
DN100 (4 in. NB)
Error (%)
0.1 (0.44) 1.0 (4.4) 10 (44) 100 (440) 1000 (4402)
WaterMaster Class 2
Specification
OIML R49 Class 2
Accuracy Limits
Q3
Typical Meter
Performance
±0.4 % ±0.9 mm/s
whichever is the greater
Error (%)
Flowrate m3/h (GPM)
±0.4 %
DN100 (4 in. NB)
WaterMaster
Electromagnetic flowmeter
6DS/WM–EN Rev. U
WaterMaster optimized full-bore meter (FEV) / full-bore meters (FEF, FEW) flow performance – m3/h
Standard Calibration – 0.4 % Class 2 High Accuracy Calibration – 0.2 % Class 1
DN Q4 Q3 Q0.4% Q2 Q1 Q0.2% Q2 Q1
10 3.1 2.5 0.167 0.013 0.008 0.31 0.02 0.012
15 7.88 6.3 0.42 0.032 0.02 0.79 0.05 0.03
20 12.5 10 0.67 0.05 0.032 1.25 0.08 0.05
25 20 16 1.1 0.08 0.05 2 0.13 0.08
32 31.25 25 1.67 0.13 0.08 3 0.20 0.13
40* 50 40 4.2 0.2 0.13 6 0.32 0.2
50* 79 63 4.2 0.32 0.20 7.9 0.5 0.32
65* 125 100 6.7 0.5 0.32 12.5 0.8 0.5
80* 200 160 10.7 0.81 0.51 16 1.3 0.8
100* 313 250 16.7 1.3 0.79 25 2 1.25
125* 313 250 16.7 1.3 0.79 25 2 1.25
150* 788 630 42 3.2 2.0 63 5 3.2
200* 1,250 1,000 67 5.1 3.2 100 8 5
250 2,000 1,600 107 8.1 5.1 160 13 8
300 3,125 2,500 167 12.7 7.9 250 20 12.5
350 5,000 4,000 267 20.3 12.7 400 32 20
400 5,000 4,000 267 20.3 12.7 400 32 20
450 7,875 6,300 420 32 20 630 50 32
500 7,875 6,300 420 32 20 630 50 32
600 12,500 10,000 667 51 32 1000 80 50
700 20,000 16,000 1600 102 64 1600 160 100
750 20,000 16,000 1600 102 64 1600 160 100
30 in (760) 20,000 16,000 1600 102 64 1600 160 100
800 20,000 16,000 1600 102 64 1600 160 100
900 31,250 25,000 2500 160 100 2500 250 156
1000 31,250 25,000 2500 160 100 2500 250 156
42 in 31,250 25,000 2500 160 100 2500 250 156
1100 31,250 25,000 2500 160 100 2500 250 156
1200 50,000 40,000 4000 256 160 4000 400 250
1350 78,750 63,000 6300 403 252 6300 630 394
1400 78,750 63,000 6300 403 252 6300 630 394
1500 78,750 63,000 6300 403 252 6300 630 394
60 in (1500) 78,750 63,000 6300 403 252 6300 630 394
1600 78,750 63,000 6300 403 252 6300 630 394
1650 78,750 63,000 6300 403 252 6300 630 394
1800 125,000 100,000 10000 640 400 10000 1000 625
1950 125,000 100,000 10000 640 400 10000 1000 625
2000 125,000 100,000 10000 640 400 10000 1000 625
2200 200,000 160,000 16000 1024 640 16000 1600 1000
2400 200,000 160,000 16000 1024 640 16000 1600 1000
* OIML R49 Certificate of Conformance to Class 1 and Class 2, with OIML R49 and MID versions available.
Note. OIML R49–1 allow Class 1 only for meters with Q3100 m3/h. Meters outside this range have been tested and conform
to Class 1.
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 7
WaterMaster optimized full-bore meter (FEV) / full-bore meters (FEF, FEW) flow performance – gal/min
WaterMaster reduced-bore meter (FER) flow performance – m3/h (gal/min)
Standard Calibration 0.4 % Class 2 High Accuracy Calibration 0.2 % Class 1
NPS/NB (DN) Q4 Q3 Q0.4% Q2 Q1 Q0.2% Q2 Q1
3/8(10) 13.8 11 0.73 0.06 0.035 1.38 0.09 0.053
1/2(15) 34.7 27.7 1.85 0.14 0.09 3.48 0.22 0.14
3/4(20) 55 44 2.94 0.22 0.14 5.5 0.35 0.22
1 (25) 88 70.4 4.7 0.35 0.22 8.8 0.57 0.35
11/4(32) 137.6 110 7.3 0.57 0.35 13.2 0.88 0.57
11/2(40) 220 176 18.5 0.89 0.56 26.4 1.41 0.88
2 (50) 347 277 18.5 1.41 0.88 34.7 2.22 1.39
21/2(65) 550 440 29.4 2.24 1.40 55.0 3.52 2.20
3 (80) 881 704 47.0 3.58 2.24 70.4 5.64 3.52
4 (100) 1,376 1,101 73.4 5.59 3.49 110 8.81 5.50
5 (125) 1,376 1,101 73.4 5.59 3.49 110 8.81 5.50
6 (150) 3,467 2,774 185 14.1 8.81 277 22.2 13.9
8 (200) 5,504 4,403 294 22.4 14.0 440 35.2 22.0
10 (250) 8,806 7,045 470 35.8 22.4 704 56.4 35.2
12 (300) 13,759 11,007 734 55.9 34.9 1,101 88.1 55.0
14 (350) 22,014 17,611 1,174 89.5 55.9 1,761 141 88.1
16 (400) 22,014 17,611 1,174 89.5 55.9 1,761 141 88.1
18 (450) 34,673 27,738 1,849 141 88.1 2,774 222 139
20 (500) 34,673 27,738 1,849 141 88.1 2,774 222 139
24 (600) 55,036 44,029 2,935 224 140 4,403 352 220
27/28* (700) 88,057 70,446 7,045 451 282 7,045 704 440
29 (750) 88,057 70,446 7,045 451 282 7,045 704 440
30 (760) 88,057 70,446 7,045 451 282 7,045 704 440
32 (800) 88,057 70,446 7,045 451 282 7,045 704 440
36 (900) 137,590 110,072 11,007 704 440 11,007 1,100 688
39/40* (1000) 137,590 110,072 11,007 704 440 11,007 1,100 688
42 (1050) 137,590 110,072 11,007 704 440 11,007 1,100 688
44 (1100) 137,590 110,072 11,007 704 440 11,007 1,100 688
48 (1200) 220,143 176,115 17,611 1,127 704 17,611 1,761 1,101
52 (1350) 346,726 277,381 27,738 1,775 1,110 27,738 2,773 1,733
54 (1400) 346,726 277,381 27,738 1,775 1,110 27,738 2,773 1,733
60 (1500) 346,726 277,381 27,738 1,775 1,110 27,738 2,773 1,733
66 (1600) 346,726 277,381 27,738 1,775 1,110 27,738 2,773 1,733
68 (1650) 346,726 277,381 27,738 1,775 1,110 27,738 2,773 1,733
77 (1800) 550,358 440,287 44,029 2,818 1,761 44,029 4,403 2,752
77 (1950) 550,358 440,287 44,029 2,818 1,761 44,029 4,403 2,752
78 (2000) 550,358 440,287 44,029 2,818 1,761 44,029 4,403 2,752
78 (2000) 550,358 440,287 44,029 2,818 1,761 44,029 4,403 2,752
84 (2200) 880,573 704,459 70,446 4,509 2,818 70,446 7,045 4,403
96 (2400) 880,573 704,459 70,446 4,509 2,818 70,446 7,045 4,403
*Size is dependent on flange specification
Class 2 specification Class 1 specification
Size Q4Q3Q0.4 % Q2Q1
RQ0.2 % Q2Q1
R
mm in. m3/ h (Ugal / min) m3/ h (Ugal / min) m3/ h (Ugal / min) m3/ h (Ugal / min) m3/ h (Ugal / min) m3/ h (Ugal / min) m3/ h (Ugal / min) m3/ h (Ugal / min)
40 11/231 (138) 25 (110) 0.83 (1.05) 0.063 (0.28) 0.04 (0.18) 630 1.7 (7.48) 0.1 (0.44) 0.063 (0.28) 400
50 2 50 (220) 40 (176) 1.0 (4.40) 0.1 (0.44) 0.063 (0.28) 630 2.0 (8.8) 0.16 (0.7) 0.1 (0.44) 400
65 21/279 (347) 63 (277) 1.6 (7.04) 0.16 (0.7) 0.1 (0.44) 630 3.2 (10.56) 0.25 (1.1) 0.16 (0.7) 400
80 3 125 (550) 100 (440) 2.0 (8.80) 0.25 (1.1) 0.16 (0.7) 630 4.0 (17.6) 0.4 (1.76) 0.25 (1.1) 400
100 4 200 (880) 160 (704) 3.2 (10.56) 0.41 (1.8) 0.25 (1.1) 630 6.4 (28) 0.64 (2.8) 0.4 (1.76) 400
125 5 200 (880) 160 (704) 3.2 (10.56) 0.41 (1.8) 0.25 (1.1) 630 6.4 (28) 0.64 (2.8) 0.4 (1.76) 400
150 6 500 (2200) 400 (1760) 8.0 (35.20) 1.0 (4.4) 0.63 (2.77) 630 16 (70.4) 1.6 (7) 1.0 (4.4) 400
200 8 788 (3470) 630 (2770) 13.0 (57.2) 1.6 (7.04) 1.0 (4.4) 630 25 (110) 2.5 (11) 1.6 (7) 400
250 10 1250 (5500) 1000 (4400) 20 (88) 2.5 (11.01) 1.6 (7) 630 40 (176) 4.0 (17.6) 2.5 (11) 400
300 12 2000 (8810) 1600 (7045) 32 (140.8) 4.1 (18.05) 2.5 (11) 630 64 (281.6) 6.4 (28) 4.0 (17.6) 200
350 14 2000 (8810) 1600 (7045) 32 (140.8) 6.4 (28.18) 4.0 (17.6) 400 64 (281.6) 12.8 (56) 8.0 (35.2) 200
375 15 2000 (8810) 1600 (7045) 32 (140.8) 6.4 (28.18) 4.0 (17.6) 400 64 (281.6) 12.8 (56) 8.0 (35.2) 200
400 16 3125 (13760) 2500 (11007) 50 (220) 10 (44) 6.3 (27.7) 400 100 (440) 20 (88) 12.5 (55) 200
450 18 3125 (13760) 2500 (11007) 50 (220) 10 (44) 6.3 (27.7) 400 100 (440) 20 (88) 12.5 (55) 200
500 20 5000 (22014) 4000 (17610) 80 (352) 16 (70.45) 10 (44) 400 160 (70.4) 32 (141) 20 (88) 200
600 24 7875 (34670) 6300 (27740) 126 (554.4) 25.2 (110.9) 15.8 (70) 400 252 (1108) 50.4 (222) 31.5 (138.7) 200
WaterMaster
Electromagnetic flowmeter
8DS/WM–EN Rev. U
Specification – sensor
Functional specification
Pressure limitations
As per flange rating – non approved
PN16 for OIML R49, MID Approved
Pressure equipment directive 97/23/EC
This product is applicable in networks for the supply, distribution and
discharge of water and associated equipment and is therefore
exempt.
Temperature limitations
IP rating
IP68 (NEMA 6) to7m(20ft.)depth
Note. Not sizes DN10 to DN32 (3/8–1
1/4in. NB)
IP67 (NEMA 4X) – DN10 to DN32 (3/8–1
1/4in. NB)
Buriable (sensor only)
FEV, FEF and FEW – DN450 to 2400 (18 to 96 in. NB)
to 5 m (16 ft.) depth
Conductivity
>5µS cm–1
Transmitter mounting
Integral (not FEF) or remote
Electrical connections
20 mm glands
1/2in. NPT
20 mm armored glands
Sensor cable
ABB WaterMaster cable available in two forms –
standard and armored
Maximum length 200 m (660 ft.)
Physical specification
Wetted parts
Electrode material
Stainless steel 316L/316Ti
Super-austenitic steel
Hastelloy®C-22 and Hastelloy C4
(other electrode materials available on request)
Potential equalizing rings
Minimum of 1 recommended
Lining material / potable water approvals
*Size is dependent on flange specification
Lining protection plates
Not required
Installation conditions (recommended)
Pressure loss
Ambient temperature
Remote transmitter
Integral transmitter
–20 to 70 °C (–4 to 158 °F)
–20 to 60 °C (–4 to 140 °F)
Process temperature See table below.
0.1 to 50 °C (32.2 to 122 °F) – OIML R49 T50
Approved
Medium temperature °C (°F)
Code Lining Flange material Minimum Maximum
FEF, FEW3 Hard rubber Carbon steel –10 (14) 90 (194)
Stainless steel –10 (14) 90 (194)
FEW1 PTFE Carbon steel –10 (14) 130 (266)
Stainless steel –25 (–13) 130 (266)
FEW3 PTFE Carbon steel –10 (14) 130 (266)
Stainless steel –10 (14) 130 (266)
FEW3 Elastomer Carbon steel –5 (23) 80 (176)
Stainless steel –5 (23) 80 (176)
FEF, FER Elastomer Carbon steel –6 (21) 70 (158)
FEV Polypropylene –6 (21) 70 (158)
Potable Water Approvals
Code Size Range Liner WRAS WRAS
60°C ACS DVGW NSF
AZ/
NZS
4020
FEW1 DN10 – 32
(3/8–1
1/4in. NB) PTFE 4
FEW3 DN10 – 600
(3/8– 24 in. NB) PTFE
FEW3 DN40 – 2400
(11/2– 96 in. NB) Elastomer 44
FEW3 DN40 – 2400
(11/2– 96 in. NB)
Hard
rubber 44 4
NSF approved
material
FEV DN40 – 200
(11/2– 8 in. NB)
Poly-
propylene 444NSF-61 4
FEF DN250 – 600
(10 – 24 in. NB) Elastomer 444NSF-61 4
FEF DN250 – 600
(10 – 24 in. NB)
Hard
rubber 44 4
NSF approved
material
FER DN40 – 600
(11/2– 24 in. NB) Elastomer 444 4
Straight pipe requirements
Upstream Downstream
FEW/FEF 5xDN 2xDN
FEV 5x DN 0 x DN
FER 0xDN 0xDN
Negligible at Q3 All full bore meters
<0.25 bar (<3.62 psi) at Q3 FEV (DN40 to 200 [11/2to 8 in. NB])
<0.63 bar (<9.13 psi) at Q3 FER (DN40 to 600 [11/2to 24in. NB])
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 9
Non-wetted parts
Flange material
Housing material
Terminal box material
Polycarbonate
Cable gland material
Plastic, brass
Paint specification
Paint coat 70 µm thick RAL 9002 (light grey)
Carbon steel DN20 to DN2400 (3/4to 96 in. NB)
Stainless steel DN10 to DN2400 (3/8to 96 in. NB)
SG iron FEV – DN40 to DN150 [1 1/2to 6 in. NB)
FER – DN40 to DN150 [1 1/2to 6 in. NB)
Carbon steel FEV – DN40 to 200 (11/2to 8 in. NB)
FEW – DN450 to 2400 (18 to 96 in. NB)
Plastic FEF – DN250 to 600 (10 to 24 in. NB)
Aluminium FEW – DN10 to 400 (3/8to 16 in. NB)
WaterMaster
Electromagnetic flowmeter
10 DS/WM–EN Rev. U
Specification – transmitter
Functional specification
Power supply
Supply voltage fluctuations within the specified range have no
effect on accuracy
Digital Outputs (3)
Rating 30 V @ 220 mA, open collector, galvanically isolated *
Maximum output frequency 5250 Hz
1 off dedicated to Alarm / Logic, programmable function
2 off configurable to either Pulse / Frequency or Alarm/Logic function
Current output – HART FEX100 variant
4 to 20 mA or 4 to 12/20 mA, galvanically isolated *
Maximum loop resistance 750
HART protocol Version 5.7 (HART registered)
Signal levels compliant with NAMUR NE 43 (3.8 to 20.5 mA)
Low alarm 3.6 mA, High alarm 21.8 mA
Additional accuracy
RS485 Communications – PROFIBUS FEX100-DP variant
Registered name: FEX100-DP
RS485 (9.6kbps to 1.5Mbps), galvanically isolated
DPV0, DPV1
PA Profile 3.01
Standard idents: 9700, 9740, 9741
FEX100-DP specific ident: 3431
3 Concurrent MS2 master connections
RS485 Communications – MODBUS FEX100-MB variant
MODBUS RTU protocol
RS485 (9.6kbps to 115.2kbps), galvanically isolated
Electrical connections
20 mm glands 1/2in. NPT, 20 mm armored glands
Temperature limitations
* When installed, do not leave galvanically isolated circuits (pulse and
current) floating.
Environmental protection
Humidity: 0 to 100 %
Rating: IP67 (NEMA 4X) to 1m (3.3 ft.) depth
Tamper-proof security
Write access prevented by internal switch combined with
external security seals for MID applications
Languages
English, French, German, Italian, Spanish, Polish
Infrared service port
USB adapter (accessory), USB 1.1. and 2.0 compatible
Driver software for Windows 2000, XP, 7 (32-bit) and Vista
Housing material
Powder-coated aluminium with glass window
Paint specification
Paint coat 70 µm thick RAL 9002 (light grey)
Transmitter vibration testing
Vibration level: 7 m/s2
Frequency range: 20 to 150 Hz
No. of sweeps in 3 orthogonal planes: 20
Undetectable shift in transmitter span or zero performance
Hazardous approvals (HART variant only)
FM & FMc Class 1 Div 2
FET, FEV, FEW and FEF DN700 to 2200 (27/28* to 84 in. NB) only
*Size is dependent on flange specification
ATEX* Zone 2, 21 & 22
IECEx* Zone 2, 21 & 22
*FEW, FEV, FET and FEF 700 (27/28 in. NB) only
Declaration of Conformance
Copies of CE certification will be available on request.
WaterMaster has OIML R49 Certificate of Conformity to accuracy
class 1 and 2 (FEV DN40 to 200 [11/2to 8 in.NB]). Copies of accuracy
certification are available on request.
WaterMaster (FEV DN40 to 200 [11/2to 8 in.NB]) has been type
examined under directive MID 2004/22/EC, Annex MI-001. Copies of
this certificate are available on request.
Mains 85 to 265 V AC @ <7 VA
Low voltage 24 V AC +10 % /–30%@<7VA
DC 24 V ±30 % @ <0.4 A
±0.1 % of reading
Temperature coefficient: typically <±20 ppm/°C
Ambient temperature –20 to 60 °C (–4 to 140 °F)
Temperature
coefficient
Typically <±10 ppm/°C @ Vel 0.5 mls
(FM listing NI/1/2/ABCD/T4,S/II,III/2/FG/T4,
Ta=60C; Type 4X, IP67 – for transmitter and integral mounting
Ta=70C, Type 6P, IP68 – for remote sensor type,
IP67 on DN10 to 32 [3/8to 11/4in.NB])
(FMc listing NI/1/2/ABCD/T4,DIP/II,III/2/FG/T4,
Ta=60C; Type 4X, IP67 – for transmitter and integral mounting
Ta=70C, Type 6P, IP68 – for remote sensor type, IP67 on
DN10 to 32 [3/8to 11/4in.NB])
II3GExnAIICT5Gc
II2DExtbIIIC T100°C Db
TA = –20°C to +60°C (integral transmitter)
TA = –20°C to +70°C (remote sensor)
Ex tb IIIC T100°C Db
Ex nA IIC T5 Gc
TA = –20°C to +60°C (integral transmitter)
TA = –20°C to +70°C (remote sensor)
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 11
Transmitter connections
Transmitter terminal connections overview
This section is intended to give an overview of installation of a flowmeter. For Installation requirements, technical information and
Health and safety precautions – refer to the User Guide OI/FET100–EN.
Sensor cable terminal connections and recommended cable lengths
Cable gland / conduit entry (Remote transmitter shown)
AC / DC Power
Supply Terminal
Power Cable Output Connections
External Earth
Output Connections Sensor Cable
Output
Connections Terminal
Sensor
Cable Terminal
Backplane
Internal Earth
(Alternative PE)
Internal Earth
(Alternative PE)
Test Points for
Output Connections
Sensor cable connections at transmitter terminal block – remote transmitter
See above for cable preparation
requirements before connecting cable
**Drain Wire (Twisted
with screen from
D1/TFE – Orange
and D2 – Yellow)
*Inner wire
**For cathodically-protected systems (or if the transmitter enclosure does not have an earth
screw) connect the drain wire to terminal SCR.
M1
Brown
M2
Red
SCR
Screen
D1/TFE
Orange
D2
Yellow
3
Green
(Sleeve)
S2
Blue
(Screen)
S1
Violet
Screen)
E2
Blue
(*Signal)
Cut cables to 70 mm (2.75 in.) Cut cables to 60 mm (2.35 in.)
E1
Violet
(*Signal)
WaterMaster
Electromagnetic flowmeter
12 DS/WM–EN Rev. U
Power supply connections
AC power supply
DC (and low voltage AC) power supply
AC power supply connections
DC (and low voltage AC) power supply connections
Transmitter Label
External Earth Screw
AC power via a suitable
isolator and fuse
*AC Fuse F1 250 mA Type T
(see table below for suppliers)
>4 mm2(<10 AWG) Copper Wire
Power Supply Indicator LED
**Can be used as a
Protective Earth (PE)
if required by
national standards
Brown
Blue
Green / Yellow
Internal Earth
Screws**
*Fuse Supplier Fuse Part Number
ABB
Bussmann
Wickmann
B20411
BK/ETF 250 mA
19372 K250mA
Power Supply Indicator LED
*DC Fuse F22ATypeT
(see table below for suppliers)
Red
Black
Green / Yellow
Internal Earth
Screws
External Earth
DC (or Low Voltage AC) power
via suitable Isolator and fuse
>4 mm2(<10 AWG) Copper Wire
Transmitter Label (DC)
*Fuse Supplier Fuse Part Number
ABB
Bussmann
Wickmann
B20412
BK/ETF2A
19372 K2A
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 13
Configuration DIP switches
Three configuration DIP switches are mounted on the
transmitter backplane board.
These are factory-set as follows:
Remote transmitter – all OFF
Integral transmitter – SW3 ON
For MID-compliant flowmeters the read-only / MID protection
switch is set to 'ON' to ensure the meter is secure from
tampering.
For HART software versions prior to 01.02.XX, this switch (set
after commissioning) prevents login via the keypad or bus at any
security level.
From HART software version 01.03.XX onwards and for all
PROFIBUS software versions, on MID meters, all
metrological-related parameters are locked and inaccessible at
the Service level. Standard and Advanced user level parameters
can still be modified via the HMI or bus.
Transmitter module identification
Configuration DIP switches
Configuration
DIP Switches
SW3 SW2 SW1
OFF
ON
SW1 – Read-only / MID Protection
SW2 – (Future Product)
SW3 – Internal Sensor Memory
DIP Switch Functions
Note. The communications bus type is HART FEX100 if not
specified on the transmitter module label. An example of the
PROFIBUS FEX100-DP variant transmitter module label is
shown below.
Transmitter module identification
Black Label on AC Converter Module
Red Label on DC
(and Low Voltage AC)
Converter Module
PROFIBUS FEX-100P Label
WaterMaster
Electromagnetic flowmeter
14 DS/WM–EN Rev. U
Output connections
Frequency outputs Alarm outputs
PLC / Datalogger connections
Note. Digital outputs DO1 and DO2 are polarity sensitive.
The common (negative) connection for these outputs is
designated 'COM'.
Electromechanical connections
Telemetry / Electronic counters connections
XX XX XX XX 42 41 51 61
52
62
PLC or Datalogger
COM DO1 DO2
Terminal connection IDs are
HART- / PROFIBUS-variant
dependent
+
123456
123456
XX XX XX XX 42 41 51 61
52
62
DC Supply
Reverse Flow
Output (DO2)
Counter / Totalizer
Forward Flow Output (DO1)
Counter / Totalizer
and/or
COM DO1 DO2
123456
123456
XX XX XX XX 42 41 51 61
52
62
+
+
and/or
COM DO1 DO2
Reverse Flow
Output (DO2)
Counter / Totalizer
Forward Flow Output (DO1)
Counter / Totalizer
Note.
Normal alarm / logic output is from DO3 (terminal 61).
DO1 (41) and DO2 (51) can also be configured as
alarms if required but are then NOT available as
frequency / pulse outputs as shown in
Electromechanical connections and
Telemetry /Electronic counters connections,
opposite.
Bell and horn shown for example only. Any suitable
alarm device may be used (for example, lamp, siren,
buzzer etc.).
Note. Relay and timer switch shown for example only.
COM DO3
Terminal connection IDs are
HART- / PROFIBUS- / MODBUS-
variant dependent
XX XX XX XX 42 41 51 61
52
62
+
DC Supply
COM DO1 DO2
Alarm 1
Alarm 2
and/or
Bell
Horn
DO3
XX XX XX XX 42 41 51 61
52
62
+
COM DO1 DO2
DC Supply
Alarm 1
Alarm 2
Relay
Timer Switch
R
and/or
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 15
PLC interface Current output (4 to 20 ma) – HART (FEX100) variant
RS485 communications – PROFIBUS (FEX100-DP) and
MODBUS (FEX100-MB) variants
Test point access
Note.
WaterMaster digital outputs are NPN optocoupled
transistors used as switches.
Maximum allowed voltage at collector is 30 V DC
Maximum allowed current across transistor is
220 mA.
XX XX XX XX 42 41 51 61
52
62
+
Fwd +
PLC
Typically
1k
1W
DC Supply
Rev +
COM
Com
24 V
DO1 DO2
XX XX XX XX 42 41 51 61
52
62
+
DC Supply
PLC
Fwd – Rev – Com
COM DO1 DO2
Current output (4 to 20 mA) – HART (FEX100) variant
Note. A typical DVM probe can access (fit) the PCB's test
holes.
*These 2 test points are connected on the HART FEX100
backplane only (they are present on the PROFIBUS
FEX100-DP / MODBUS FEX100-MB backplane but not
connected)
+–
Refer to IM/WMP for HART-Protocol
communication details
PROFIBUS / MODBUS RS485
A1/B1–In
A2/B2–Out
Screen Clamp
31 32 XX
42
41
51
61
VR
IC+*IC–* Not Used
O/P1
4to20mA
COM
O/P2
O/P3 Alarm Output
Not Used
Frequency
Outputs
WaterMaster
Electromagnetic flowmeter
16 DS/WM–EN Rev. U
Digital communication
The transmitter has the following options for digital
communication.
HART protocol
The unit is registered with HART Communication Foundation.
System integration
WaterMaster can be integrated into control systems and
configuration devices using any Frame application, such as ABB
AssetVision or similar third-party applications. ABB Device Type
Managers (DTMs) for WaterMaster provide a unified structure for
accessing device parameters, configuring and operating the
devices and diagnosing problems. FDT (Field Device Tool)
technology standardizes the communication and configuration
interface between all field devices and host systems.
PROFIBUS DP protocol
PROFIBUS is a manufacturer-independent, open Fieldbus
standard for a wide range of applications in manufacturing,
process and building automation. Manufacturer independence
and openness are ensured by the international standard EN
50170.
All devices are connected in a bus structure ('line') as shown in
below. Up to 32 stations (master or slaves) can be linked to
create one 'segment', although it is recommended not to install
more than 16 devices on a single segment. Each end of a
segment must be terminated by an active bus terminating
resistor. Both bus terminators must always be powered to
ensure fault-free operation, therefore it is strongly recommended
that they are connected to a back-up power supply. The use of
bus amplifiers (repeaters) and segment couplers can be used to
extend the network.
HART protocol
Configuration Directly on the Device
Software Asset Vision Basic (+ HART -DTM)
Transmission Install a HART modem (FSK [Frequency Shift
Keyed]-Modem) for HART-Communication when
connecting to a PC. The HART-Modem converts the
analog 4 to 20 mA signal into a digital output signal
(Bell Standard 202) and connects to the PC using a
USB (or RS232C) connector
Max. signal
amplitude
1.2 mA
Current output load Min. 250, max. = 560
Cable AWG 24 twisted
Max. cable length 1500 m (4921 ft.)
Baud rate 1.200 baud
HART FSK-Modem
or Handheld Terminal
4 mA Current Output
(Multidrop Connection)
4 to 20 mA Current Output
(Single Connection) –
see User Guide IM/WMP
PC connection
(USB or RS232)
Multidrop Connection
Sensor
250 Minimum Load
Single
Connection
HART Connections
at Terminal Block
PROFIBUS DP ID no. 0x3431
Alternative standard ID
no.
0x9701 or 0x9741
Configuration Directly on the device
Software Asset Vision Basic
(+PROFIBUS DP-DTM)
Transmission signal Accuracy to IEC 61158-2
Cable Shielded, twisted cable (accurate to IEC
61158-2, types A or B)
Operational
Level
Master
Level
Engineer Operate
Control
PROFIBUS-DP
DP /
PA Link
PROFIBUS-PA
WaterMaster
FEX100-DP
Slave
Level
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 17
System integration
The GSD file for WaterMasters specifies the device-specific
Ident No. 3431. It conforms to the PROFIBUS standard,
providing a clear and comprehensive description of each
instrument in a precisely defined format.
This enables the system configuration tool to use the information
automatically when configuring a PROFIBUS bus system.
The ABB GSD file (Ident No. 3431) is divided into 2 sections:
General specifications
Identification of the device, together with hardware and
software versions, baud rates supported and the possible
time intervals for monitoring times.
DP slave-related specifications
Information about the user parameter block for
device-specific configuration and modules containing
details of the input and output data that can be
exchanged cyclically with a PROFIBUS master.
The WaterMaster GSD file (ABB_3431.gsd) is available for
download from the ABB website at: www.abb.com/fieldbus
(follow the link for PROFIBUS DP field devices).
MODBUS protocol
MODBUS is an open standard that is owned and administered
by an independent group of device manufacturers called the
Modbus Organization (www.modbus.org).
Using the MODBUS protocol, devices from different
manufacturers exchange information on the same
communications bus without the need for special interface
equipment. WaterMaster FEX100-MB follows the specification
for Modbus Over Serial Line V1.02, using 2-wire TIA/EIA-485
(RS485) physical layer.
Cable Properties
The end-to-end length of the trunk cable must be limited. The
maximum length depends on the Baud rate, the cable (gauge,
capacitance or characteristic impedance), the number of loads
on the daisy chain and the network configuration (2-wire or
4-wire).
For 9600 Baud rate and AWG26 (or wider) gauge, the maximum
length is 1000 m (3280 ft.). Where 4-wire cabling is used as a
2-wire cabling system the maximum length must be divided by
2. The tap cables must be short, never more than 20 m (65.6
ft.). If a multi-port tap is used with n derivations, each one must
have a maximum length of 40 m (131 ft.) divided by n.
The maximum serial data transmission line length for RS485
systems is 1200 m (3937 ft.). The lengths of cable that can be
used are determined by the cable type, typically:
Up to 6 m (19.7 ft.) – standard screened or twisted pair
cable.
Up to 300 m (984 ft.) – twin twisted pair with overall foil
screen and an integral drain wire – for example, Belden
9502 or equivalent.
Up to 1200 m (3937 ft.) – twin twisted pair with separate
foil screens and integral drain wires – for example, Belden
9729 or equivalent.
Category 5 cables may be used for RS485-MODBUS to a
maximum length of 600 m (1968 ft.). For the balanced pairs
used in an RS485-system, a characteristic impedance with
value higher than 100is preferred especially for 19200 and
higher Baud rates.
Master
5
Slave n
Slave 1
Pull
Pull
Down
Line
D0
D1
Common
Balanced Pair
Line
Terminator
Up to 31 slaves
For example, WaterMaster FEX100–MOD
DR
DR
DR
Pull
Up
WaterMaster
Electromagnetic flowmeter
18 DS/WM–EN Rev. U
Installation requirements
This section is intended to give an overview of installation of a
flowmeter. For Installation requirements, technical information
and Health and Safety precautions refer to User Guide
OI/FEF/FEV/FEW–EN.
Unpacking the flowmeter
Care must be taken when lifting the flowmeter to use the lifting
hooks provided or sling under the body of the meter. Never lift
using the terminal connection box of the sensor cable as this will
cause damage and invalidate warranty.
Grounding
The flowmeter sensor must be cross-bonded to the upstream
and downstream pipes and fluid. For technical reasons, this
potential should be identical to the potential of the metering
fluid. For plastic or insulated lined pipelines, the fluid is grounded
by installing a minimum of 1 earthing rings. When there are stray
potentials present in the pipeline, an earthing ring is
recommended on both ends of the meter sensor.
Mounting
The installation conditions shown below must be observed to
achieve the best operational results.
The sensor tube must always be completely full.
The flow direction must correspond to the identification plate.
The device measures the flowrate in both directions. Forward
flow is the factory setting.
The devices must be installed without mechanical tension
(torsion, bending). If required support the pipeline.
The flange seals must be made from a compatible material for
the fluid and fluid temperatures if required.
Seals must not extend into the flow area since possible
turbulence could influence the device accuracy.
Sling Angle <90°
Fluid contact rings
Supports
70 / 130 °C
(158 / 266 °F)
Max.
–2C
(– 4 °F)
Min.
Fit Gaskets
Gaskets Same Size as Pipe
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 19
The pipeline may not exert any unallowable forces and torques
on the device, such as vibration.
The flowmeter must not be submitted to any localized heat
during installation; take care to remember this is a measuring
instrument.
The flowmeter must not be exposed to direct sunlight or provide
for appropriate sun protection where necessary.
The cable to the flowmeter should be installed neatly or within a
conduit, both loose or conduit should have a u shape below the
terminal connection box height to allow any water run off to
avoid any capillary action into the flowmeter sensor.
Electrode axis
Electrode axis should be horizontal if at all possible or no more
than 45° from horizontal.
Upstream and Downstream pipe sections
The metering principle is tolerant of the flow profile.
Wherever possible do not install fittings (for example,
manifolds, valves) directly in front of the flowmeter sensor.
Butterfly valves should be installed so that the valve plate
does not extend into the flowmeter sensor.
Valves or other turn-off components should be installed in
the Downstream pipe section.
Experience has shown that, in most installations, straight
upstream sections 3 x DN long and straight downstream
sections 2 x DN long are normally sufficient. We would
recommend conditions of 5 x DN straight upstream and 2 x DN
straight downstream where possible.
For reduced-bore meters (FER), these straight pipe sections are
often not necessary.
45 ° Max.
5 x DN (FEW, FEF)
0 x DN (FER)
5 x DN (FEV)
2 x DN (FEW, FEF)
0 x DN (FER)
0 x DN (FEV)
WaterMaster
Electromagnetic flowmeter
20 DS/WM–EN Rev. U
Transmitter dimensions
Integral transmitter Remote transmitter
Sensor dimensions
FEW – DN10 to 125 (3/8to 5 in. NB)
Dimensions in mm (in.)
98 (3.8) 202 (8.0)
118 (4.6)
200 (7.9)
Dimensions in mm (in.)
205 (8.0)
179 (7.0)
R3.2 (0.12)
71 (2.8)
98 (3.8)
Dimensions in mm (in.)
DN10 to 125 (3/8to 5 in. NB) (FEW)
G
F
E
77.8 (3.06)
89
(3.5)
104.5 (4.11)
Ø104
(4.1)
78
(3.1)
210
(7.91)
98 (3.86)
D
L
A
C
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 21
Dimensions in mm (in.) Approx. weight in kg (lb)
DN Process connection type D L F C E G A Integral Remote
DN10
(3/8in.)
JIS10K 90 (3.54) 200 (7.87) 268 (10.55) 82 (3.23) 193 (7.6) 148 (5.83) 113 (4.45) 6 (13) 4 (9)
PN10 to 40 90 (3.54)
ASME B16.5 CL150 90 (3.54)
ASME B16.5 CL300 96 (3.78)
DN15
(1/2in.)
PN10 to 40 95 (3.74)
JIS5K 80 (3.15)
JIS10K 95 (3.74)
ASME B16.5 CL300 95 (3.74)
ASME B16.5 CL150 90 (3.54)
DN20
(3/4in.)
PN10 to 40 105 (4.13) 8 (18) 6 (13)
JIS5K 85 (3.35)
JIS10K 100 (3.94)
ASME B16.5 CL300 115 (4.53)
ASME B16.5 CL150 98 (3.86)
DN25
(1 in.)
PN10 to 40 115 (4.53) 200 (7.87) 268 (10.55) 82 (3.23) 193 (7.6) 148 (5.83) 113 (4.45) 9 (20) 7 (15)
JIS5K 95 (3.74)
JIS10K 125 (4.88)
ASME B16.5 CL300 125 (4.88)
ASME B16.5 CL150 108 (4.25)
DN32
(11/4in.)
PN10 to 40 140 (5.51) 275 (10.83) 92 (3.62) 200 (7.87) 155 (6.10) 113 (4.45) 10 (22) 8 (18)
JIS5K 115 (4.53)
JIS10K 135 (5.31)
ASME B16.5 CL300 135 (5.31)
ASME B16.5 CL150 117 (4.61)
DN40
(11/2in.)
PN10 to 40 150 (5.91) 11 (24) 9 (20)
JIS5K 120 (4.72)
JIS10K 140 (5.51)
ASME B16.5 CL300 155 (6.10)
ASME B16.5 CL150 127 (5.00)
DN50
(2 in.)
PN10 to 40 165 (6.5) 281 (11.06) 97 (3.82) 206 (8.11) 161 (6.34) 115 (4.53) 12 (26) 10 (22)
JIS5K 130 (5.12)
JIS10K 155 (6.10)
AS4087 PN16 150 (5.91)
AS4087 PN35 165 (6.50)
ASME B16.5 CL150 152 (5.98)
ASME B16.5 CL300 165 (6.50)
DN65
(21/2in.)
PN10 to 40 185 (7.28) 292 (11.50) 108 (4.25) 217 (8.54) 172 (6.77) 104 (4.09) 13 (29) 11 (24)
JIS5K 155 (6.10)
JIS10K 175 (6.89)
AS4087 PN16 165 (6.50)
AS4087 PN35 185 (7.28)
ASME B16.5 CL150 178 (7.01)
ASME B16.5 CL300 190 (7.48) 15 (33) 13 (29)
DN80
(3 in.)
PN10 to 40 200 (7.87) 292 (11.5) 108 (4.25) 217 (8.54) 172 (6.77) 104 (4.09) 17 (37) 15 (33)
JIS5K 180 (7.09)
JIS10K 185 (7.28)
AS4087 PN16 185 (7.28)
AS4087 PN35 205 (8.07)
ASME B16.5 CL150 190 (7.48)
ASME B16.5 CL300 210 (8.28) 19 (42) 17 (37)
DN100
(4 in.)
PN10 to 16 220 (8.66) 250 (9.84) 314 (12.36) 122 (4.8) 239 (9.41) 194 (7.64) 125 (4.92) 19 (42) 17 (37)
PN25 to 40 235 (9.25) 23 (51) 21 (46)
JIS5K 200 (7.87) 19 (42) 17 (37)
JIS10K 210 (8.27)
AS4087 PN16 215 (8.46)
AS4087 PN35 230 (9.06) 23 (51) 21 (46)
ASME B16.5 CL300 255 (1.04) 30 (66) 28 (62)
ASME B16.5 CL150 229 (9.00) 21 (51) 19 (42)
DN125
(5 in.)
PN10 to 16 250 (9.84) 324 (12.76) 130 (5.12) 249 (9.8) 204 (8.03) 125 (4.92) 22 (48) 20 (44)
PN25 to 40 270 (10.63) 29 (64) 27 (59)
JIS5K 235 (9.25) 22 (48) 20 (44)
JIS10K 250 (9.84)
ASME B16.5 CL150 254 (10.00)
ASME B16.5 CL300 280 (11.02) 35 (77) 33 (73)
DN10 to 125 (3/8to 5 in. NB) (FEW) dimensions / weights
WaterMaster
Electromagnetic flowmeter
22 DS/WM–EN Rev. U
FEW – DN150 to 400 (6 to 16 in. NB)
Dimensions in mm (in.)
DN150 to 400 (6 to 16 in. NB) (FEW)
D
EF
G
C
A
L
89
(3.5)
77.8
(3.06)
Ø104
(4.1)
104.5
(4.11)
98
(3.86)
78
(3.1)
201
(7.91)
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 23
Dimensions in mm (in.) Approx. weight in kg (lb)
DN Process connection type D L F C E G A Integral Remote
DN150
(6 in.)
PN10 to 16 285 (11.22) 300 (11.81) 371 (14.61) 146 (9.88) 296 (11.65) 251 (9.88) 166 (6.54) 33 (73) 31 (68)
PN25 to 40 300 (11.81) 39 (86) 37 (81)
JIS5K 265 (10.43) 33 (73) 31 (68)
JIS10K 280 (11.02)
AS4087 PN16 280 (11.02)
AS4087 PN35 305 (11.81) 39 (86) 37 (81)
ASME B16.5 CL300 320 (12.60) 47 (103) 45 (99)
ASME B16.5 CL150 279 (10.98) 33 (73) 31 (68)
DN200
(8 in.)
PN10 340 (13.39) 350 (13.78) 411 (16.18) 170 (6.69) 336 (13.23) 291 (11.46) 200 (7.87) 41 (90) 39 (86)
PN16 340 (13.39)
PN25 360 (14.17) 55 (121) 53 (117)
PN40 375 (14.76) 65 (143) 63 (139)
AS4087 PN16 335 (13.19) 41 (90) 39 (86)
AS4087 PN35 370 (14.57) 65 (143) 63 (139)
JIS5K 320 (12.60) 41 (90) 39 (86)
JIS10K 330 (12.99)
ASME B16.5 CL300 380 (14.96) 72 (158) 70 (154)
ASME B16.5 CL150 345 (13.58) 50 (110) 48 (106)
DN250
(10 in.)
PN10 395 (15.55) 450 (17.72) 426 (16.77) 198 (7.80) 351 (13.82) 306 (12.05) 235 (9.62) 61 (134) 59 (130)
PN16 405 (15.94) 65 (143) 63 (139)
PN25 425 (16.73) 84 (185) 82 (180)
PN40 450 (17.72) 95 (209) 93 (205)
AS4087 PN16 405 (15.94) 65 (143) 63 (139)
AS4087 PN35 430 (16.93) 95 (209) 93 (205)
JIS5K 385 (15.16) 65 (143) 63 (139)
JIS10K 400 (15.75)
ASME B16.5 CL300 445 (17.52) 105 (231) 103 (227)
ASME B16.5 CL150 405 (15.94) 70 (154) 68 (150)
DN300
(12 in.)
PN10 445 (17.52) 500 (19.69) 449 (17.68) 228 (8.98) 374 (14.72) 329 (12.95) 272 (10.71) 74 (163) 72 (158)
PN16 460 (18.11) 80 (176) 78 (172)
PN25 485 (19.09) 100 (220) 98 (216)
JIS5K 430 (16.93) 80 (176) 78 (172)
JIS10K 445 (17.52)
AS4087 PN16 455 (17.91)
AS4087 PN35 490 (19.29) 130 (286) 128 (282)
ASME B16.5 CL300 520 (20.47) 150 (330) 148 (326)
ASME B16.5 CL150 485 (19.09) 105 (231) 103 (227)
PN40 515 (20.28) 600 (23.62) 130 (286) 128 (282)
DN350
(14 in.)
PN10 505 (19.88) 550 (21.65) 464 (18.27) 265 (10.43) 389 (15.31) 344 (13.54) 322 (12.68) 95 (209) 93 (205)
PN16 520 (20.47) 110 (242) 108 (238)
PN25 555 (21.85) 145 (319) 143 (315)
JIS5K 480 (18.90) 95 (209) 93 (205)
JIS10K 490 (19.29)
AS4087 PN16 525 (20.67) 130 (286) 128 (282)
AS4087 PN35 550 (21.65) 185 (407) 183 (403)
ASME B16.5 CL300 585 (23.03) 140 (308) 138 (304)
ASME B16.5 CL150 535 (21.06) 105 (231) 103 (227)
PN40 580 (22.83) 650 (25.59) 195 (429) 193 (425)
DN400
(16 in.)
PN10 565 (22.24) 600 (23.62) 506 (19.92) 265 (10.43) 431 (16.97) 386 (15.20) 322 (12.68) 103 (227) 101 (222)
PN16 580 (22.83) 126 (277) 124 (273)
PN25 620 (24.41) 170 (374) 168 (370)
JIS5K 540 (21.26) 103 (227) 101 (223)
JIS10K 560 (22.05) 116 (255) 114 (251)
AS4087 PN16 580 (22.83) 154 (339) 152 (335)
AS4087 PN35 610 (24.02) 302 (664) 300 (660)
ASME B16.5 CL300 650 (25.59) 265 (583) 263 (578)
ASME B16.5 CL150 600 (23.62) 175 (385) 173 (381)
PN40 660 (25.98) 650 (25.59) 258 (568) 256 (564)
DN150 to 400 (6 to 5 in. NB) (FEW) dimensions / weights
WaterMaster
Electromagnetic flowmeter
24 DS/WM–EN Rev. U
FEW – DN450 to 2400 (18 to 96 in. NB)
Dimensions in mm (in.)
DN450 to 2400 (18 to 96 in. NB) (FEW)
F
E
C
G
89
(3.5)
77.8
(3.06)
104
(4.1)
104.5
(4.11)
98
(3.86)
201
(7.91)
78
(3.1)
A
D
L (1.0D)
L (1.3D)
Dimensions in mm (in.) Approx. weight in kg (lb)
DN Process connection type D L (1.0D) L (1.3D) F C E G A Integral Remote
DN450
(18 in.)
PN10 615 (24.21) N/A 600
(23.62)
514 (20.24) 310 (12.20) 439 (17.28) 394 (15.51) 328 (12.91) 173 (381) 171 (377)
PN16 640 (25.20) 188 (414) 186 (410)
JIS5K 605 (23.82) 165 (364) 163 (359)
JIS10K 620 (24.41) 177 (390) 175 (386)
AS4087 PN16 640 (25.20) 232 (511) 230 (507)
AS4087 PN35 675 (26.57) 328 (723) 326 (718)
ASME B16.5 CL300 710 (27.95) 368 (811) 366 (807)
ASME B16.5 CL150 635 (25.00) 250 (551) 248 (547)
PN25 670 (26.38) N/A 686
(27.01)
245 (540) 243 (536)
PN40 685 (26.97) 315 (694) 313 (690)
DN500
(20 in.)
PN10 670 (26.38) N/A 600
(23.62)
514 (20.24) 310 (12.20) 439 (17.28) 394 (15.51) 367 (14.45) 190 (418) 188 (413)
PN16 715 (28.15) 240 (528) 238 (524)
JIS5K 655 (25.79) 190 (418) 188 (413)
JIS10K 675 (26.57)
AS4087 PN16 705 (27.76) 290 (638) 288 (634)
AS4087 PN35 735 (28.94) 435 (957) 433 (953)
ASME B16.5 CL150 700 (27.56) 300 (660) 298 (656)
ASME B16.5 CL300 775 (30.51) N/A 762 490 (1080) 488 (1076)
PN25 730 (28.74) N/A 700 300 (661) 298 (657)
PN40 755 (29.72) N/A 762 392 (864) 390 (860)
DN600
(24 in.)
PN10 780 (30.71) N/A 800
(31.50)
565 (22.24) 361 (14.21) 490 (19.29) 445 (17.52) 469 (18.46) 284 (626) 282 (622)
PN16 840 (33.07) 318 (700) 316 (695)
PN25 845 (33.27) 460 (1012) 458 (1008)
JIS5K 770 (30.31) 275 (605) 273 (600)
JIS10K 795 (31.30) 306 (673) 304 (668)
AS4087 PN16 825 (32.48) 382 (840) 380 (835)
AS4087 PN35 850 (33.46) 452 (994) 450 (990)
ASME B16.5 CL300 915 (36.02) 550 (1210) 548 (1205)
ASME B16.5 CL150 815 (32.09) 425 (935) 423 (930)
PN40 890 (35.04) N/A 890 600 (1320) 598 (1316)
DN450 to 2400 (18 to 96 in. NB) (FEW) dimensions / weights
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 25
DN700
(28 in.)
JIS 5K 875 (34.45) 700
(27.56)
910
(35.83)
604 (23.77) 403 (15.87) 528 (20.79) 488 (19.21) 444 (17.48) 216 (475) 214 (471)
JIS 10K 905 (35.63) 282 (620) 280 (616)
PN6 860 (33.86) 225 (495) 223 (491)
PN10 895 (35.24) 303 (667) 301 (662)
PN16 910 (35.83) 337 (741) 335 (737)
AWWA C207 CLASS B 927 (36.50) 249 (548) 247 (543)
AWWA C207 CLASS D 927 (36.50) 280 (616) 278 (612)
AS4087 PN16 910 (35.83) 359 (790) 357 (785)
AS2129 TABLE-D 910 (35.83) 263 (579) 261 (574)
AS2129 TABLE-E 910 (35.83) 337 (741) 335 (737)
PN25 960 (37.80) 471 (10.36) 469 (1032)
PN40 995 (39.17) 586 (1289) 584 (1285)
AWWA C207 CLASS E 927 (36.50) 472 (1038) 470 (1034)
AWWA C207 CLASS F 1035 (40.75) 715 (1573) 713 (1569)
AS4087 PN35 935 (36.80) 539 (1186) 537 (1181)
ASME CL150 SERIES A 925 (36.42) 503 (1107) 501 (1102)
ASME CL150 SERIES B 835 (32.87) 323 (711) 321 (706)
ASME CL300 SERIES B 920 (36.22) 631 (1388) 629 (1384)
DN750
(30 in.)
JIS 5K 945 (37.20) 750
(29.52)
990
(38.98)
630 (24.79) 429 (16.89) 554 (21.81) 514 (20.23) 444 (17.48) 251 (552) 249 (548)
JIS 10K 970 (38.19) 327 (719) 325 (715)
AWWA C207 CLASS B 984 (38.74) 273 (601) 271 (596)
AWWA C207 CLASS D 984 (38.74) 344 (757) 342 (752)
AS4087 PN16 995 (39.17) 467 (1027) 465 (1023)
AS2129 TABLE-D 995 (39.17) 340 (748) 338 (744)
AS2129 TABLE-E 995 (39.17) 454 (999) 452 (994)
AWWA C207 CLASS E 984 (38.74) 496 (1091) 494 (1087)
AWWA C207 CLASS F 1092 (43.99) 790 (1738) 788 (1734)
AS4087 PN35 1015 (39.96) 663 (1459) 661 (1454)
ASME CL150 SERIES A 985 (38.78) 544 (1197) 542 (1192)
ASME CL150 SERIES B 885 (34.84) 320 (704) 318 (700)
ASME CL300 SERIES B 990 (38.98) 748 (1646) 746 (1641)
DN800
(32 in.)
JIS 5K 995 (39.17) 800
(31.49)
1040
(40.04)
654 (25.74) 453 (17.83) 578 (22.76) 538 (21.18) 542 (21.34) 280 (616) 278 (612)
JIS 10K 1020 (40.16) 364 (801) 362 (796)
PN6 975 (38.39) 294 (647) 292 (642)
PN10 1015 (39.96) 406 (893) 404 (889)
PN16 1025 (40.35) 469 (1032) 467 (1027)
AWWA C207 CLASS B 1060 (41.73) 328 (722) 326 (717)
AWWA C207 CLASS D 1060 (41.73) 408 (898) 406 (893)
AS4087 PN16 1060 (41.73) 530 (1166) 528 (1162)
AS2129 TABLE-D 1060 (41.73) 386 (849) 384 (845)
AS2129 TABLE-E 1060 (41.73) 519 (1142) 517 (1137)
PN25 1085 (42.72) 615 (1353) 613 (1349)
PN40 1140 (44.88) 866 (1905) 864 (1901)
AWWA C207 CLASS E 1060 (41.73) 634 (1395) 632 (1390)
AWWA C207 CLASS F 1150 (45.28) 897 (1973) 895 (1969)
AS4087 PN35 1060 (41.73) 751 (1652) 749 (1648)
ASME CL150 SERIES A 1060 (41.73) 700 (1540) 698 (1536)
ASME CL150 SERIES B 940 (37.01) 406 (893) 404 (889)
ASME CL300 SERIES B 1055 (41.54) 933 (2053) 931 (2048
DN900
(36 in.)
JIS 5K 1095 (43.11) 900
(35.43)
1170
(46.06)
705 (27.7() 504 (19.84) 629 (24.76) 589 (23.19) 570 (22.44) 369 812) 367 (807)
JIS 10K 1120 (44.09) 445 (979) 443 (975)
PN6 1075 (42.32) 390 (858) 388 (854)
PN10 1115 (43.90) 502 (1104) 500 (1100)
PN16 1125 (44.29) 589 (1296) 587 (1291)
AWWA C207 CLASS B 1168 (45.98) 417 (917) 415 (913)
AWWA C207 CLASS D 1168 (45.98) 493 (1085) 491 (1080)
AWWA C207 CLASS E 1168 (45.98) 827 (1819) 825 (1815)
AWWA C207 CLASS F 1270 (50.00) 1150 (2530) 1148 (2526)
AS4087 PN16 1175 (46.26) 706 (1553) 704 (1549)
AS2129 TABLE-D 1175 (46.26) 514 (1131) 512 (1126)
AS2129 TABLE-E 1175 (46.26) 694 (1527) 692 (1522)
PN25 1185 (46.65) 819 (1802) 817 (1797)
PN40 1250 (49.21) 1158 (2548) 1156 (2543)
AS4087 PN35 1185 (46.65) 1044 (2297) 1042 (2292)
ASME CL150 SERIES A 1170 (46.06) 961 (2114) 959 (2110)
ASME CL150 SERIES B 1055 (41.54) 595 (1309) 593 (1305)
ASME CL300 SERIES B 1170 (46.06) 1147 (2523) 1145 (2519)
Dimensions in mm (in.) Approx. weight in kg (lb)
DN Process connection type D L (1.0D) L (1.3D) F C E G A Integral Remote
DN450 to 2400 (18 to 96 in. NB) (FEW) dimensions / weights (Continued)
WaterMaster
Electromagnetic flowmeter
26 DS/WM–EN Rev. U
Dimensions in mm (in.)
…DN450 to 2400 (18 to 96 in. NB) (FEW)
F
E
C
G
89
(3.5)
77.8
(3.06)
104
(4.1)
104.5
(4.11)
98
(3.86)
201
(7.91)
78
(3.1)
A
D
L (1.0D)
L (1.3D)
Dimensions in mm (in.) Approx. weight in kg (lb)
DN Process connection type D L (1.0D) L (1.3D) F C E G A Integral Remote
DN1000
(40 in.)
JIS 5K 1195 (47.05) 1000
(39.37)
1300
(51.18)
755 (29.71) 554 (21.81) 679 (26.73) 639 (25.16) 624 (24.57) 441 (970) 439 (966)
JIS 10K 1235 (48.62) 572 (1258) 570 (1254)
PN6 1175 (46.26) 466 (1025) 464 (1021)
PN10 1230 (48.43) 674 (1483) 672 (1478)
PN16 1255 (49.41) 879 (1934) 877 (1929)
AWWA C207 CLASS B 1289 (50.75) 503 (1107) 501 (1102)
AWWA C207 CLASS D 1289 (50.75) 659 (1450) 657 (1445)
AWWA C207 CLASS E 1289 (50.75) 1028 (2262) 1026 (2257)
AWWA C207 CLASS F 1378 (54.25) 1367 (3007) 1365 (3003)
AS4087 PN16 1255 (49.41) 831 (1828) 829 (1824)
AS2129 TABLE-D 1255 (49.41) 610 (1342) 608 (1338)
AS2129 TABLE-E 1255 (49.41) 833 (1833) 831 (1028)
PN25 1320 (51.97) 1207 (2655) 1205 (2651)
PN40 1360 (53.54) 1413 (3109) 1411 (3104)
AS4087 PN35 1275 (50.20) 1244 (2737) 1242 (2732)
ASME CL150 SERIES A 1290 (50.79) 1149 (2528) 1147 (2523)
ASME CL300 SERIES A 1240 (48.82) 1349 (2968) 1347 (2963)
ASME CL150 SERIES B 1175 (46.26) 738 (1624) 736 (1619)
ASME CL300 SERIES B 1275 (50.20) 1487 (3271) 1485 (3267)
DN1050
(42 in.)
AWWA C207 CLASS B 1346 (5299) 1050
(41.33)
1365
(53.74)
808 (31.82) 608 (23.92) 733 (28.84) 693 (27.28) 624 (24.57) 564 (1241) 562 (1236)
AWWA C207 CLASS D 1346 (5299) 669 (1472) 667 (1467)
AWWA C207 CLASS E 1346 (5299) 1143 (2515) 1141 (2510)
AWWA C207 CLASS F 1448 (57.01) 1568 (3450) 1566 (3445)
ASME CL150 SERIES B 1225 (48.23) 809 (1780) 807 (1775)
ASME CL150 SERIES A 1345 (52.95) 1289 (2836) 1287 (2831)
ASME CL300 SERIES A 1290 (50.79) 1527 (3359) 1525 (3355)
ASME CL300 SERIES B 1335 (52.56) 1704 (3749) 1702 (3744)
DN1100
(44 in.)
JIS 5K 1305 (51.38) 1100
(43.30)
1430
(56.30)
510 (1122) 508 (1118)
JIS 10K 1345 (52.95) 689 (1516) 687 (1511)
AWWA C207 CLASS B 1403 (55.24) 615 (1353) 613 (1349)
AWWA C207 CLASS D 1403 (55.24) 807 (1775) 805 (1771)
AWWA C207 CLASS E 1404 (55.26) 1205 (2651) 1203 (2647)
AWWA C207 CLASS F 1505 (59.25) 1719 (3782) 1717 (3777)
…DN450 to 2400 (18 to 96 in. NB) (FEW) dimensions / weights
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 27
DN1200
(48 in.)
JIS 5K 1420 (55.91) 1200
(47.24)
1560
(61.42)
860 (33.85) 659 (25.94) 784 (30.87) 744 (29.29) 802 (31.57) 651 (1432) 649 (1428)
JIS 10K 1465 (57.68) 967 (2127) 965 (2123)
PN6 1405 (55.31) 710 (1562) 708 (1558)
PN10 1455 (57.28) 1107 (2435) 1105 (2431)
PN16 1485 (58.46) 1363 (2999) 1361 (2994)
AWWA C207 CLASS B 1511 (59.49) 772 (1698) 770 (1694)
AWWA C207 CLASS D 1511 (59.49) 999 (2198) 997 (2193)
AWWA C207 CLASS E 1511 (59.49) 1458 (3208) 1456 (3203)
AWWA C207 CLASS F 1651 (65.00) 2400 (5280) 2398 (5276)
AS4087 PN16 1490 (58.66) 1253 (2757) 1251 (2752)
AS2129 TABLE-D 1490 (58.66) 1023 (2251) 1021 (2246)
AS2129 TABLE-E 1490 (58.66) 1272 (2798) 1270 (2794)
PN25 1530 (60.24) 1559 (3430) 1557 (3425)
PN40 1575 (62.01) 2133 (4693) 2131 (4688)
AS4087 PN35 1530 (60.24) 2115 (4653) 2113 (4649)
ASME CL150 SERIES A 1510 (59.45) 1707 (3755) 1705 (3751)
ASME CL300 SERIES A 1465 (57.68) 2163 (4759) 2161 (4754)
ASME CL150 SERIES B 1390 (54.72) 1085 (2387) 1083 (2383)
ASME CL300 SERIES B 1510 (59.45) 2352 (5174) 2350 (5170)
DN1350
(54 in.)
AWWA C207 CLASS B 1683 (66.26) 1350
(53.15)
1755
(69.09)
955 (37.59) 754 (29.69) 879 (34.61) 839 (33.03) 902 (35.51 981 (2158) 979 (2154)
AWWA C207 CLASS D 1683 (66.26) 1213 (2669) 1211 (2664)
AWWA C207 CLASS E 1683 (66.26) 1942 (4272) 1940 (4268)
DN1400
(56 in.)
PN6 1630 (64.17) 1400
(55.11)
1820
(71.65)
1085 (2387) 1083 (2383)
PN10 1675 (65.94) 1731 (3808) 1729 (3804)
PN16 1685 (66.34) 1770 (3894) 1768 (3890)
ASME CL150 SERIES B 1600 (62.99) 1593 (3505) 1591 (3500)
PN25 1755 (69.09) 2368 (5210) 2366 (5205)
PN40 1795 (70.67) 3086 (6789) 3084 (6785)
ASME CL150 SERIES A 1745 (68.70) 2556 (5623) 2554 (5619)
ASME CL300 SERIES A 1710 (67.32) 3376 (7427) 3374 (7423)
ASME CL300 SERIES B 1765 (69.49) 3758 (8268) 3756 (8263)
DN1500
(60 in.)
JIS 5K 1730 (68.11) 1500
(59.05)
1950
(76.77)
1065 (41.92) 864 (34.02) 989 (38.94) 949 (37.36) 910 (35.83) 1029 (2264) 1027 (2259)
JIS 10K 1795 (70.67) 1504 (3309) 1502 (3304)
ASME CL150 SERIES B 1725 (67.91) 2031 (4468) 2029 (4464)
AWWA C207 CLASS B 1854 (72.99) 1229 (2704) 1227 (2699)
AWWA C207 CLASS D 1854 (72.99) 1514 (3331) 1512 (3326)
AWWA C207 CLASS E 1854 (72.99) 2544 (5597) 2542 (5592)
ASME CL150 SERIES A 1855 (73.03) 3084 (6785) 3082 (6780)
ASME CL300 SERIES A 1810 (71.26) 3875 (8525) 3873 (8521)
ASME CL300 SERIES B 1880 (74.02 4181 (9198) 4179 (9194)
DN1600
(64 in.)
PN6 1830 (72.05) 1600
(62.99)
2080
(81.89)
1066 (41.96) 865 (34.06) 990 (38.98) 950 (37.4) 1000 (39.37) 1434 (3155) 1432 (3150)
PN10 1915 (75.39) 2525 (5555) 2523 (5551)
PN25 1975 (77.76) 3201 (7042) 3199 (7038)
PN16 1930 (75.98) 2768 (6090) 2766 (6085)
PN40 2025 (79.72) 4375 (9625) 4373 (9621)
DN1650
(66 in.)
AWWA C207 CLASS B 2032 (80.00) N/A 2145
(84.45)
1116 (43.94) 915 (36.02) 1040 (40.94) 1000 (39.37) 1000 (39.37) 1504 (3309) 1502 (3304)
AWWA C207 CLASS D 2032 (80.00) 2025 (4455) 2023 (4451)
DN1800
(72 in.)
PN6 2045 (80.51) N/A 2340
(92.13)
1181 (46.50) 980 (38.58) 1105 (43.50) 1065 (41.93) 1100 (43.31) 1853 (4077) 1851 (4072)
PN10 2115 (83.27) 3180 (6996) 3178 (6992)
PN16 2130 (83.86) 3657 (8045) 3655 (8041)
PN25 2195 (86.42) 4422 (9728) 4420 (9724)
AWWA C207 CLASS B 2197 (86.50) 1773 (3901) 1771 (3896)
AWWA C207 CLASS D 2197 (86.50) 2387 (5251) 2385 (5247)
DN1950
(78 in.)
AWWA C207 CLASS B 2362 (92.99) N/A 2535
(99.80)
1291 (50.81) 1090 (42.91) 1215 (47.83) 1175 (46.26) 1180 (46.46) 2309 (5080) 2307 (5075)
AWWA C207 CLASS D 2362 (92.99) 3037 (6681) 3035 (6677)
DN2000
(80 in.)
PN6 2265 (89.17) N/A 2600
(102.36)
2581 (5678) 2579 (5674)
PN10 2325 (91.54) 4254 (9359) 4252 (9354)
PN16 2345 (92.32) 4556 4554
PN25 2425 (95.47) 5896 5894
DN2100
(84 in.)
AWWA C207 CLASS B 2534 (99.76) N/A 2730
(107.48)
1395 (54.91) 1194 (47.01) 1319 (51.93) 1279 (50.35) 1180 (46.46) 2641 (5810) 2639 (5806)
AWWA C207 CLASS D 2534 (99.76) 3487 (7671) 3485 (7667)
DN2200
(88 in.)
PN6 2475 (97.44) N/A 2860
(112.60)
1330 (52.36) 3363 (7399) 3361 (7394)
PN10 2550 (100.39) 5795 5793
DN2400
(96 in.)
PN6 2685 (105.71 N/A 3120
(122.83)
1495 (58.85) 1294 (50.94) 1419 (55.87) 1379 (54.29) 1450 (57.09) 4100 (9020) 4098 (9016)
PN10 2760 (108.66) 6968 6966
Dimensions in mm (in.) Approx. weight in kg (lb)
DN Process connection type D L (1.0D) L (1.3D) F C E G A Integral Remote
…DN450 to 2400 (18 to 96 in. NB) (FEW) dimensions / weights (Continued)
WaterMaster
Electromagnetic flowmeter
28 DS/WM–EN Rev. U
FEV – DN40 to 200 (11/2to 8 in. NB)
Dimensions in mm (in.)
DN40 to 200 (11/2to 8 in. NB) (FEV)
L
D
E
C
G
89
(3.5)
77.8
(3.06)
Ø104
(4.1)
104.5
(4.11)
98
(3.86)
78
(3.1)
201
(7.91)
X
X
F
Dimensions in mm (in.) Approx. weight in kg (lb)
DN Process connection type D L F E G X Integral Remote
DN40
(11/2in.)
EN1092-1 PN10, 16, 25, 40 150 (5.91) 200 (7.87) 260 (10.24) 185 (7.28) 137 (5.39) 30 (1.18) 12.8 (28.16) 11.8 (25.96)
ASME B16.5 CLASS 150
AS2129 TABLE D, E, F
DN50
(2 in.)
EN1092-1 PN10, 16, 25, 40 165 (6.50) 200 (7.87) 261 (10.28) 186 (7.32) 138 (5.43) 38 (1.5) 13.75 (30.25) 12.75 (28.05)
ASME B16.5 CLASS 150
DN80
(3 in.)
EN1092-1 PN10, 16, 25, 40 200 (7.87) 200 (7.87) 280 (11.04) 205.5 (8.09) 157.5 (6.2) 61 (2.4) 17.2 (37.84) 16.2 (35.64)
ASME B16.5 CLASS 150
AS4087 PN16, 21
AS2129 TABLE D, E, F
DN100
(4 in.)
EN1092-1 PN10, 16, 25, 40 225 (8.86) 250 (9.84) 300.5 (11.83) 225.5 (8.88) 177.5 (6.98) 70 (2.76) 19.3 (42.5) 18.3 (40.3)
ASME B16.5 CLASS 150
AS4087 PN16
DN150
(6 in.)
EN1092-1 PN10, 16, 25, 40 300 (11.81) 300 (11.81) 333.5 (13.13) 258.5 (10.18) 210.5 (8.29) 103 (4.06) 35.1 (77.2) 34.1 (75)
ASME B16.5 CLASS 150
AS4087 PN16
DN200
(8 in.)
EN1092-1 PN10, 16 375 (11.76) 350 (13.78) 358.7 (14.12) 283.7 (11.17) 235.7 (9.28) 150 (5.91) 67 (147.4) 66 (145.2)
ASME B16.5 CLASS 150
AS2129 TABLE C, D, E, F
AS4087 PN14, 16, 21
WaterMaster integral / remote FEV – DN40 to 200 (11/2to 8 in.) cast iron sensor dimensions / weights
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 29
Dimensions in mm (in.) Approx. weight in kg (lb)
DN Process connection type D L F C E G X Integral Remote
DN40
(11/2in.)
EN1092-1 PN10, PN40 150 (5.91) 200 (7.87) 260 (10.24) 30.4 (1.20) 185 (7.28) 138 (5.43) 30 (1.18) 12 (27) 11 (24)
ASME B16.5 CLASS 150 127 (5.00)
JIS 10K 140 (5.51)
AS2129 TABLE F 140 (5.51)
AS2129 TABLECDE 135(5.31)
AS4087 PN14 135 (5.31)
DN50
(2 in.)
EN1092-1 PN10, PN16 165 (6.50) 200 (7.87) 270 (10.63) 38.3 (1.51) 195 (7.68) 146 (5.75) 38 (1.50) 13 (29) 12 (27)
ASME B16.5 CLASS 150 152.4 (6.00)
JIS 10K 155 (6.10)
AS4087 PN21 165 (6.50)
AS2129 TABLE F 165 (6.50)
AS2129 TABLECDE 150(5.91)
AS4087 PN14, PN16 150 (5.91)
DN65
(21/2in.)
AS4087 PN14, PN16 165 (6.50) 200 (7.87) 275 (10.83) 45.2 (1.78) 200 (7.87) 152 (5.98) 48 (1.89) 15 (33) 14 (31)
AS2129 TABLECDE 165(6.50)
EN1092-1 PN10 185 (7.28)
EN1092-1 PN16 185 (7.28)
DN80
(3 in.)
EN1092-1 PN10, PN16 200 (7.87) 200 (7.87) 280 (11.02) 51.5 (2.03) 205 (8.07) 156 (6.14) 61 (2.40) 16 (36) 15 (33)
ASME B16.5 CLASS 150 190 (7.48)
JIS 7.5K 211 (8.31)
JIS 10K 185 (7.28)
AS2129 TABLECDE 185(7.28)
AS4087 PN14, PN16 185 (7.28)
AS2129 TABLE F 205 (8.07)
AS4087 PN21 205 (8.07)
DN100
(4 in.)
EN1092-1 PN10, PN16 220 (8.66) 250 (9.84) 320 (12.60) 63.75 (2.51) 245 (9.65) 196.8 (7.75) 70 (2.76) 19 (42) 18 (40)
ASME B16.5 CLASS 150 228.6 (9.00)
JIS 7.5K 238 (9.37)
JIS 10K 210 (8.27)
AS2129 TABLE C D 215 (8.46)
AS4087 PN14, PN16 215 (8.46)
AS2129 TABLE E 215 (8.46)
AS4087 PN21 230 (9.06)
AS2129 TABLE F 230 (9.06)
DN125
(5 in.)
EN1092-1 PN10, PN16 250 (9.84) 250 (9.84) 320 (12.60) 63.75 (2.51) 245 (9.65) 197 (7.76) 70 (2.76) 20 (44) 19 (42)
ASME B16.5 CLASS 150 254 (10.00)
JIS 10K 250 (9.84)
AS2129 TABLECDE 255(10.04)
AS2129 TABLE F 280 (11.02)
DN150
(6 in.)
EN1092 PN10, PN16 285 (11.22) 300 (11.81) 340 (13.39) 84.4 (3.32) 265 (10.43) 217 (8.54) 103 (4.06) 32 (70) 31 (68)
ASME B16.5 CLASS 150 279 (10.98)
JIS 7.5k 290 (11.42)
JIS 10K 280 (11.02)
AS2129 TABLE C D 280 (11.02)
AS4087 PN14, PN16 280 (11.02)
AS2129 TABLE E 280 (11.02)
AS2129 TABLE F 305 (12.01)
AS4087 PN21 305 (12.01)
DN200
(8 in.)
EN1092-1 PN10 340 (13.39) 350 (13.78) 365 (14.37) 109.8 (4.32) 290 (11.42) 243 (9.57) 150 (5.91) 49 (108) 48 (105)
EN1092-1 PN16 340 (13.39)
ASME B16.5 CLASS 150 345 (13.58)
JIS 7.5K 342 (13.46)
JIS 10K 330 (12.99)
AS2129 TABLE C D 335 (13.19)
AS4087 PN14, PN 16 335 (13.19)
AS2129 TABLE E 335 (13.19)
AS2129 TABLE F 370 (14.57)
AS4087 PN21 370 (14.57)
DN40 to 200 (11/2to 8 in. NB) (FEV) dimensions / weights
WaterMaster
Electromagnetic flowmeter
30 DS/WM–EN Rev. U
FER – DN40 to 300 (11/2to 12 in. NB)
Dimensions in mm (in.)
DN40 to 300 (11/2to 12 in. NB) (FER)
L
D
E
C
G
89
(3.5)
77.8
(3.06)
Ø104
(4.1)
104.5
(4.11)
98
(3.86)
78
(3.1)
201
(7.91)
X
X
F
Dimensions in mm (in.) Approx. weight in kg (lb)
DN Process connection type D L F E G X Integral Remote
DN40
(11/2in.)
EN1092-1 PN10, 16, 25, 40 150 (5.91) 200 (7.87) 260 (10.24) 185 (7.28) 137 (5.39) 23.5 (0.93) 13.4 (29.5) 12.4 (27.3)
ASME B16.5 CLASS 150
AS2129 TABLE D, E, F
DN50
(2 in.)
EN1092-1 PN10, 16, 25, 40 165 (6.50) 200 (7.87) 261 (10.28) 186 (7.32) 138 (5.43) 29 (1.14) 14.75 (32.45) 13.75 (30.25)
ASME B16.5 CLASS 150
DN80
(3 in.)
EN1092-1 PN10, 16, 25, 40 200 (7.87) 200 (7.87) 280 (11.04) 205.5 (8.09) 157.5 (6.2) 47 (1.85) 21.2 (46.64) 20.2 (44.4)
ASME B16.5 CLASS 150
AS4087 PN16, 21
AS2129 TABLE D, E, F
DN100
(4 in.)
EN1092-1 PN10, 16, 25, 40 225 (8.86) 250 (9.84) 300.5 (11.83) 225.5 (8.88) 177.5 (6.98) 64 (2.52) 27.3 (60) 26.3 (58)
ASME B16.5 CLASS 150
AS4087 PN16
DN150
(6 in.)
EN1092-1 PN10, 16, 25, 40 300 (11.81) 300 (11.81) 333.5 (13.13) 258.5 (10.18) 210.5 (8.29) 100.2 (3.94) 27.3 (60) 26.3 (58)
ASME B16.5 CLASS 150
AS4087 PN16
DN200
(8 in.)
EN1092-1 PN10, 16 375 (11.76) 350 (13.78) 358.7 (14.12) 283.7 (11.17) 235.7 (9.28) 126.7 (5.00) 68 (150) 67 (147.4)
ASME B16.5 CLASS 150
AS2129 TABLE C, D, E, F
AS4087 PN14, 16, 21
DN40 to 200 (11/2to 8 in.) (FER) cast iron sensor dimensions / weights
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 31
Dimensions in mm (in.) Approx. weight in kg (lb)
DN Process connection type D L F C E G X Integral Remote
DN40
(11/2in.)
EN1092-1 PN10, 16, 25, 40 150 (5.91) 200 (7.87) 260 (10.24) 30.4 (1.20) 185 (7.28) 138 (5.43) 23.5 (0.93) 13 (29) 11 (24)
ASME B16.5 CLASS 150 127 (5.00)
JIS 10K 140 (5.51)
AS2129 TABLECDE 135(5.31)
AS2129 TABLE F 140 (5.51)
AS4087 PN14 135 (5.31)
DN50
(2 in.)
EN1092-1 PN10, 16, 25, 40 165 (6.50) 200 (7.87) 270 (10.63) 38.3 (1.51) 195 (7.68) 146 (5.75) 29 (1.14) 14 (31) 12 (27)
ASME B16.5 CLASS 150 152.4 (6.00)
JIS 10K 155 (6.10)
AS4087 PN21 165 (6.50)
AS2129 TABLE F 165 (6.50)
AS2129 TABLECDE 150(5.91)
AS4087 PN14, PN16 150 (5.91)
DN65
(21/2in.)
EN1092-1 PN10, 16, 25, 40 185 (7.28) 200 (7.87) 275 (10.83) 45.2 (1.78) 200 (7.87) 152 (5.98) 37 (1.46) 15 (33) 13 (29)
ASME B16.5 CLASS 150 178 (7.00)
JIS10K 175 (6.89)
AS2129 TABLECDE 165(6.50)
AS2129 TABLE F 185 (7.28)
AS4087 PN14, 16 165 (6.50)
AS4087 PN21 185 (7.28)
DN80
(3 in.)
EN1092-1 PN10, 16, 25, 40 200 (7.87) 200 (7.87) 280 (11.02) 51.5 (2.03) 205 (8.07) 156 (6.14) 47 (1.85) 20 (44) 18 (40)
ASME B16.5 CLASS 150 190 (7.48)
JIS 10K 185 (7.28)
AS2129 TABLECDE 185(7.28)
AS4087 PN14, 16 185 (7.28)
AS2129 TABLE F 205 (8.07)
AS4087 PN21 205 (8.07)
DN100
(4 in.)
EN1092-1 PN10, 16 220 (8.66) 250 (9.84) 320 (12.60) 63.75 (2.51) 245 (9.65) 196.8 (7.75) 64 (2.52) 27 (59) 25 (55)
EN1092-1 PN25, 40 235 (9.25)
ASME B16.5 CLASS 150 228.6 (9.00)
JIS 7.5K 238 (9.37)
JIS 10K 210 (8.27)
AS2129 TABLE C D 215 (8.46)
AS4087 PN14, 16 215 (8.46)
AS4087 PN21 230 (9.06)
DN125
(5 in.)
EN1092-1 PN10, 16 250 (9.84) 250 (9.84) 320 (12.60) 63.75 (2.51) 245 (9.65) 197 (7.76) 64 (2.52) 27 (59) 25 (55)
EN1092-1 PN25, 40 270 (10.63)
ASME B16.5 CLASS 150 254 (10.00)
JIS 10K 250 (9.84)
AS2129 TABLE C D 255 (10.04)
DN150
(6 in.)
EN1092 PN10, 16 285 (11.22) 300 (11.81) 340 (13.39) 84.4 (3.32) 265 (10.43) 217 (8.54) 100.2 (3.94) 33 (72) 31 (68)
EN1092 PN25, 40 300 (11.81)
ASME B16.5 CLASS 150 279 (10.98)
JIS 7.5k 290 (11.42)
JIS 10K 280 (11.02)
AS2129 TABLE C D 280 (11.02)
AS4087 PN14, 16 280 (11.02)
AS4087 PN21 305 (12.01)
DN200
(8 in.)
EN1092-1 PN10, 16 340 (13.39) 350 (13.78) 365 (14.37) 109.8 (4.32) 290 (11.42) 243 (9.57) 126.7 (4.99) 50 (110) 48 (106)
EN1092-1 PN25, 40 360 (14.17)
ASME B16.5 CLASS 150 345 (13.58)
JIS 7.5K 342 (13.46)
JIS 10K 330 (12.99)
AS2129 TABLE C D 335 (13.19)
AS4087 PN14, 16 335 (13.19)
AS4087 PN21 370 (14.57)
DN250
(10 in.)
EN1092-1 PN10 395 (15.55) 450 (17.72) 389 (15.31) 136.8 (5.39) 313 (12.33) 268 (10.55) 153.5 (6.04) 77 (169) 75 (165)
EN1092-1 PN16 405 (15.94)
EN1092-1 PN25 425 (16.73)
ASME B16.5 CLASS 150 405 (15.94)
JIS 7.5K 400 (15.75)
JIS 10K 400 (15.75)
AS2129 TABLE C D 405 (15.94)
AS4087 PN14, 16 405 (15.94)
AS4087 PN21 430 (16.93)
DN300
(12 in.)
EN1092-1 PN10 445 (17.52) 500 (19.69) 414 (16.30) 162.2 (6.39) 338.6 (13.33) 294 (1157) 203.5 (8.01) 114 (251) 112 (247)
EN1092-1 PN16 460 (18.11)
EN1092-1 PN25 485 (19.09)
ASME B16.5 CLASS 150 485 (19.09)
JIS 10K 445 (17.52)
AS2129 TABLE C D 455 (17.91)
AS4087 PN14, 16 455 (17.91)
AS4087 PN21 490 (19.29)
DN40 to 300 (11/2to 12 in. NB) (FER) dimensions / weights
WaterMaster
Electromagnetic flowmeter
32 DS/WM–EN Rev. U
FER – DN350 to 600 (14 to 24 in. NB) remote sensor
Dimensions in mm (in.)
DN350 to 600 (14 to 24 in. NB) (FER) remote sensor
X
86 (3.4)
Ø104
(4.1)
G
C
L
A
D
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 33
Dimensions in mm (in.) Approx. weight in kg (lb)
DN Process connection type D L F C E G A X Remote
DN350 (14 in.) EN1092-1 PN10 505 (19.88) 550 (21.65) 472 (18.58) 231 (9.09) 402 (15.83) 325 (12.80) 376 (14.80) 340 (13.39) 100 (220)
EN1092-1 PN16 520 (20.47)
EN1092-1 PN25 555 (21.85)
EN1092-1 PN40 580 (22.83)
JIS 5K 480 (18.90)
JIS 10K 490 (19.29)
AS2129 TABLECDE 525(20.67)
AS2129 TABLE F 550 (21.65)
AS4087 PN14, PN16 525 (20.67)
AS4087 PN21 550 (21.65)
DN400 (16 in.) EN1092-1 PN10 565 (22.24) 600 (23.62) 502 (19.76) 257.5 (10.14) 432 (17.01) 355 (13.98) 420 (16.54) 390 (15.35) 115 (253)
EN1092-1 PN16 580 (22.83)
EN1092-1 PN25 620 (24.41)
EN1092-1 PN40 660 (25.98)
JIS 5K 540 (21.26)
JIS 10K 560 (22.05)
AS2129 TABLECDE 580(22.83)
AS2129 TABLE F 610 (24.02)
AS4087 PN14, PN16 580 (22.83)
AS4087 PN21 610 (24.02)
DN450 (18 in.) EN1092-1 PN10 615 (24.21) 700 (27.56) 537 (21.14) 285 (11.22) 467 (18.39) 390 (15.35) 480 (18.90) 440 (17.32) 160 (352)
EN1092-1 PN16 640 (25.20)
EN1092-1 PN25 670 (26.38)
EN1092-1 PN40 685 (26.97)
JIS 5K 605 (23.82)
JIS 10K 620 (24.41)
AS2129 TABLECDE 640(25.20)
AS2129 TABLE F 675 (26.57)
AS4087 PN14, PN16 640 (25.20)
AS4087 PN21 675 (26.57)
DN500 (20 in.) EN1092-1 PN10 670 (26.38) 770 (30.31) 557 (21.93) 317.5 (12.50) 487 (19.17) 410 (16.14) 520 (20.47) 490 (19.29) 217 (477)
EN1092-1 PN16 715 (28.15)
EN1092-1 PN25 730 (28.74)
EN1092-1 PN40 755 (29.72)
JIS 5K 655 (25.79)
JIS 10K 675 (26.57)
AS2129 TABLECDE 705(27.76)
AS2129 TABLE F 735 (28.94)
AS4087 PN14, PN16 705 (27.76)
AS4087 PN21 735 (28.94)
DN600 (24 in.) EN1092-1 PN10 780 (30.71) 920 (36.22) 602 (23.70) 345 (13.58) 532 (20.94) 455 (17.91) 610 (24.02) 591 (23.27) 315 (693)
EN1092-1 PN16 840 (33.07)
EN1092-1 PN25 845 (33.27)
EN1092-1 PN40 890 (35.04)
JIS 5K 770 (30.31)
JIS 10K 795 (31.30)
AS2129 TABLECDE 825(32.48)
AS2129 TABLE F 850 (33.46)
AS4087 PN14, PN16 825 (32.48)
AS4087 PN21 850 (33.46)
DN350 to 600 (14 to 24 in. NB) (FER) remote sensor dimensions / weights
WaterMaster
Electromagnetic flowmeter
34 DS/WM–EN Rev. U
FEF – DN250 to 600 (10 to 24 in. NB)
Dimensions in mm (in.)
*Dimension C = centre line to base of flowmeter body
DN250 to 600 (10 to 24 in. NB) (FEF)
X
86 (3.4)
Ø104
(4.1)
G
C
L
A
D
*Base
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 35
Dimensions in mm (in.)
DN Process connection type D L C G A X Approx. weight in kg (lb)
DN250
(10 in.)
ASME B16.5 CLASS 150 405 (15.94) 450 (17.72) 215 (8.46) 301 (11.85) 300 (11.81) 250 (9.84) 88 (194)
ASME B16.5 CLASS 300 445 (17.52) 490 (19.29)
EN1092 -1 PN10 395 (15.55) 450 (17.72)
EN1092 – 1 PN16 405 (15.94)
EN1092 – 1 PN25 425 (16.73) 490 (19.29)
EN1092 – 1 PN40 450 (17.72)
JIS 5K 385 (15.16) 450 (17.72)
JIS 10K 400 (15.75)
AS4087 PN14, PN16 405 (15.94)
AS2129 TABLE C D
AS2129 TABLE E
AS4087 PN21 430 (16.93)
AS2129 TABLE F
DN300
(12 in.)
ASME B16.5 CLASS 150 485 (19.09) 500 (19.69) 231 (9.09) 317 (12.48) 352 (13.86) 300 (11.81) 128 (282)
ASME B16.5 CLASS 300 520 (20.47) 540 (21.26)
EN1092 – 1 PN10 445 (17.52) 500 (19.69)
EN1092 – 1 PN16 460 (18.11) 500 (19.69)
EN1092 – 1 PN25 485 (19.09) 540 (21.26)
EN1092 – 1 PN40 515 (20.28) 540 (21.26)
JIS 5K 430 (16.93) 500 (19.69)
JIS 10K 445 (17.52) 500 (19.69)
AS4087 PN14, PN16 455 (17.91) 500 (19.69)
AS2129 TABLE TABLE C D 455 (17.91) 500 (19.69)
AS2129 TABLE E 455 (17.91) 500 (19.69)
AS4087 PN21 490 (19.29) 500 (19.69)
AS2129 TABLE F 490 (19.29) 500 (19.69)
DN350
(14 in.)
ASME B16.5 CLASS 150 535 (21.06) 550 (21.65) 257.5 (10.14) 346 (13.62) 376 (14.80) 350 (13.78) 100 (220)
ASME B16.5 CLASS 300 585 (23.03) 570 (22.44)
EN1092 – 1 PN10 505 (19.88) 550 (21.65)
EN1092 – 1 PN16 520 (20.47) 550 (21.65)
EN1092 – 1 PN25 555 (21.85) 570 (22.44)
EN1092 – 1 PN40 580 (22.83) 570 (22.44)
JIS 5K 480 (18.90) 550 (21.65)
JIS 7.5K 530 (20.87) 550 (21.65)
JIS 10K 490 (19.29) 550 (21.65)
AS4087 PN14, PN16 525 (20.67) 550 (21.65)
AS2129 TABLECDE 525(20.67) 550 (21.65)
AS4087 PN21 550 (21.65) 550 (21.65)
AS2129 TABLE F 550 (21.65) 550 (21.65)
AS4087 PN35 550 (21.65) 570 (22.44)
AS2129 TABLE H 550 (21.65) 570 (22.44)
DN375
(15 in.)
AS4087 PN14, PN16 550 (21.65) 550 (21.65) 257.5 (10.14) 346 (13.62) 376 (14.80) 350 (13.78) 115 (253)
AS2129 TABLE C 550 (21.65) 550 (21.65)
AS4087 PN35 580 (22.83) 570 (22.44)
DN400
(16 in.)
ASME B16.5 CLASS 150 600 (23.62) 600 (23.62) 285 (11.22) 371 (14.61) 420 (16.54) 400 (15.75) 115 (253)
ASME B16.5 CLASS 300 650 (25.59) 620 (24.41)
EN1092 – 1 PN10 565 (22.24) 600 (23.62)
EN1092 – 1 PN16 580 (22.83) 600 (23.62)
EN1092 – 1 PN25 620 (24.41) 620 (24.41)
EN1092 – 1 PN40 660 (25.98) 620 (24.41)
JIS 5K 540 (21.26) 600 (23.62)
JIS 7.5K 582 (22.91) 600 (23.62)
JIS 10K 560 (22.05) 600 (23.62)
AS4087 PN14, PN16 580 (22.83) 600 (23.62)
AS2129 TABLECDE 580(22.83) 600 (23.62)
AS4087 PN21 610 (24.02) 600 (23.62)
AS2129 TABLE F 610 (24.02) 600 (23.62)
AS4087 PN35 610 (24.02) 620 (24.41)
AS2129 TABLE H 610 (24.02) 620 (24.41)
DN250 to 600 (10 to 24 in. NB) (FEF) dimensions / weights
WaterMaster
Electromagnetic flowmeter
36 DS/WM–EN Rev. U
Dimensions in mm (in.)
*Dimension C = centre line to base of flowmeter body
…DN250 to 600 (10 to 24 in. NB) (FEF)
X
86 (3.4)
Ø104
(4.1)
G
C
L
A
D
*Base
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 37
Dimensions in mm (in.)
DN Process connection type D L C G A X Approx. weight in kg (lb)
DN450
(18 in.)
ASME B16.5 CLASS 150 635 (25.00) 700 (27.56) 317.5 (12.50) 402 (15.83) 480 (18.90) 450 (17.72) 160 (352)
ASME B16.5 CLASS 300 710 (27.95)
EN1092 – 1 PN10 615 (24.21)
EN1092 – 1 PN16 640 (25.20)
EN1092 – 1 PN25 670 (26.38)
EN1092 – 1 PN40 685 (26.97)
JIS 5K 605 (23.82)
JIS 7.5K 652 (25.67)
JIS 10K 620 (24.41)
AS4087 PN14, PN16 640 (25.20)
AS2129 TABLE C D 640 (25.20)
AS2129 TABLE E 640 (25.20)
AS4087 PN21 675 (26.57)
AS2129 TABLE F 675 (26.57)
AS4087 PN35 675 (26.57)
AS2129 TABLE H 675 (26.57)
DN500
(20 in.)
ASME B16.5 CLASS 150 700 (27.56) 770 (30.31) 345 (13.58) 429 (16.89) 520 (20.47) 500 (19.69) 217 (455)
ASME B16.5 CLASS 300 775 (30.51)
EN1092 – 1 PN10 670 (26.38)
EN1092 – 1 PN16 715 (28.15)
EN1092 – 1 PN25 730 (28.74)
EN1092 – 1 PN40 755 (29.72)
JIS 5K 655 (25.79)
JIS 7.5K 706 (27.80)
JIS 10K 675 (26.57)
AS4087 PN 14, PN16 705 (27.76)
AS2129 TABLECDE 705(27.76)
AS4087 PN21 735 (28.94)
AS2129 TABLE F 735 (28.94)
AS4087 PN35 735 (28.94)
AS2129 TABLE H 735 (28.94)
DN600
(24 in.)
ASME B16.5 CLASS 150 815 (32.09) 920 (36.22) 387.5 (15.25) 472 (18.58) 610 (24.02) 600 (23.62) 315 (693)
ASME B16.5 CLASS 300 915 (36.02)
EN1092 – 1 PN10 780 (30.71)
EN1092 – 1 PN16 840 (33.07)
EN1092 – 1 PN25 845 (33.27)
EN1092 – 1 PN40 890 (35.04)
JIS 5K 770 (30.31)
JIS 7.5K 810 (31.89)
JIS 10K 795 (31.30)
AS4087 PN14, PN16 825 (32.48)
AS2129 TABLE C D 825 (32.48)
AS2129 TABLE E 825 (32.48)
AS4087 PN21 850 (33.46)
AS2129 TABLE F 850 (33.46)
AS4087 PN35 850 (33.46)
AS2129 TABLE H 850 (33.46)
…DN250 to 600 (10 to 24 in. NB) (FEF) dimensions / weights
WaterMaster
Electromagnetic flowmeter
38 DS/WM–EN Rev. U
Ordering information
Electromagnetic flowmeter WaterMaster – FEW11, FEW12 and FEW18
Product coding field number 1 … 5 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27
Options
Flowmeter system – full bore,
integral mount (DN10 to DN32 only) FEW11
X XXX XXXX XX X XXXXXXXXXXXFlowmeter system – full bore, remote mount FEW12
Full bore sensor only – for use with WaterMaster
transmitter / remote FEW18
Design
Non-hazardous areas
Hazardous areas
1
5
Bore diameter
DN10 (3/8in.)
DN15 (1/2in.)
DN20 (3/4in.)
DN25 (1 in.)
DN32 (11/4in.)
010
015
020
025
032
Liner material
PTFE – DN10 to 32 (3/8to 11/4in. NB) A
Electrode design
Standard
Other
1
9
Measuring electrodes material
Hastelloy®C-4 (2.4610) D
Grounding accessories
Not required
One potential equalizing ring (stainless steel)
Two potential equalizing rings (stainless steel)
Other
0
3
4
9
Process connection type (refer to pages 21 and 20)
ASME B16.5 B class 150
ASME B16.5 B class 300
ISO / EN PN40
DIN PN40
Other
A1
A3
S4
D4
Z9
Process connection material
Carbon steel flanges – DN20 to 32 (3/4to 11/4in. NB)
Stainless steel flange 1.4571 (316 Ti) – DN10 to 15 (3/8to 1/2in. NB)
Other
B
D
Z
Usage certifications
Standard (without PED)
Other
1
9
Calibration type
Class 2 calibration – standard accuracy 0.4 %
Class 1 calibration – high accuracy 0.2 %
Extended range, class 1 calibration – high accuracy 0.2 %
Extended range, class 2 calibration – standard accuracy 0.4 %
A
B
N
P
Temperature range installation / ambient temperature range
Standard design / –20 … 60 °C (–4 … 140 °F) 1
Nameplate
Adhesive A
Signal cable length and type
Without signal cable
5 m (15 ft.) cable
10 m (30 ft.) cable
20 m (60 ft.) cable
30 m (100 ft.) cable
50 m (165 ft.) cable
80 m (260 ft.) cable
100 m (325 ft.) cable
150 m (490 ft.) cable
Special length or cable type
0
1
2
3
4
5
6
7
8
9
Explosion protection certification
General purpose (non-Ex design)
FM Class 1 Div. 2
usFMc Class 1 Div. 2
ATEX / IECEx Zone 2, 21 & 22
A
G
P
M
Continued on next page…
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 39
Protection class transmitter / protection class sensor
IP67 (NEMA 4X) / IP67 (NEMA 4X) – cable not fitted and potted to sensor
IP67 (NEMA 4X) / IP67 (NEMA 4X) – cable fitted and potted to sensor
1
7
Cable conduits*
M20 x 1.5 (plastic)
NPT 1/2in. (blanked when cable not fitted)
M20 SWA (armored)
M20 SWA sensor, M20 x 1.5 (plastic) power / output
Without
A
B
D
F
Y
Power supply
Without
100... 230 V AC, 50 Hz
24VACor24VDC,50Hz
100... 230 V AC, 60 Hz
24VACor24VDC,60Hz
0
1
2
3
4
Input and output signal type
HART + 20 mA + pulse + contact output
PROFIBUS DP RS485 physical layer + pulse + contact output (general-purpose design only)
MODBUS RTU RS485 physical layer + pulse + contact output (general-purpose design only)
Without
A
G
M
Y
Configuration type / diagnostics type
Not required
Factory default/ standard
0
1
Options**
Accessories
Configuration lead AC
Documentation language
German
Italian
Spanish
French
English
M1
M2
M3
M4
M5 (default)
Chinese
Swedish
Finnish
Portuguese
Danish
Norwegian
M6
M7
M8
MA
MF
MN
Verification type
Without fingerprint
VeriMaster
V0
V3
Potable water approval
WRAS cold water approval
Without
CWA
CWY
Power supply frequency (FEW 18 only)
50 Hz
60 Hz
F5
F6
Number of testpoints (FEW 10 to 32 only)
1 Point
3 Points
T1
T3
* For FM or FMC Approved versions, NPT only permitted.
** Add codes for options.
Product coding field number 1 … 5 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27
Options
Flowmeter system – full bore,
integral mount (DN10 to DN32 only) FEW11
X XXX XXXX XX X XXXXXXXXXXXFlowmeter system – full bore, remote mount FEW12
Full bore sensor only – for use with WaterMaster
transmitter / remote FEW18
WaterMaster
Electromagnetic flowmeter
40 DS/WM–EN Rev. U
Electromagnetic flowmeter WaterMaster FEV11, FEV12 and FEV18
Product coding field number 1 … 5 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27
Options
Flowmeter system, optimized full bore, integral mount FEV11
X XXX XXXX XX X XXXXXXXXXXX
Flowmeter system, optimized full bore, remote mount FEV12
Optimized full bore sensor only, for use with WaterMaster
transmitter / remote FEV18
Design
Non-hazardous areas
Hazardous areas
1
5
Bore diameter
DN40 (11/2in.)
DN50 (2 in.)
DN65 (21/2in.)
DN80 (3 in.)
DN100 (4 in.)
DN125 (5 in.)
DN150 (6 in.)
DN200 (8 in.)
040
050
065
080
100
125
150
200
Liner material
Polypropylene – DN40 to 200 (11/2to 8 in. NB) V
Electrode design
Standard 1
Measuring electrodes material
Stainless steel 316
Hastelloy®C-22
Super-austenitic steel
S
C
U
Grounding accessories
Standard
One potential equalizing ring (stainless steel)
Two potential equalizing rings (stainless steel)
1
3
4
Process connection type (refer to pages 29 and 28)
Flanges ASME B16.5 class 150
Flanges AS 4087 PN21 (DN50 [2 in. NB])
Flanges AS 4087 PN16 (DN50 [2 in. NB])
Flanges AS 4087 PN14
Flanges AS 2129 Table F
Flanges AS 2129 Table E
Flanges AS 2129 Table D
Flanges AS 2129 Table C
Flanges JIS G5527 7.5K (³ DN100 [4 in. NB])
Flanges JIS B2220 10K
ISO/EN PN10
ISO / EN PN16 (DN50 [2 in. NB])
ISO / EN PN40 (DN40 [11/2in. NB] only) 16 bar rated
A1
E0
E1
E2
E3
E4
E5
E6
J0
J1
S1
S2
S4
Process connection material
Carbon steel flanges B
Usage certifications
Standard 1
Calibration type
Class 2 Calibration – standard accuracy 0.4 %
Class 1 Calibration – high accuracy 0.2 %
Extended range, class 1 calibration – high accuracy 0.2 %
Extended range, class 2 calibration – standard accuracy 0.4 %
A
B
N
P
Continued on next page…
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 41
Temperature range installation / ambient temperature range
Standard design / –20 … 60 °C (–4 … 140 °F) 1
Nameplate
Adhesive A
Signal cable length and type*
Without signal cable
5 m (15 ft.) cable
10 m (30 ft.) cable
20 m (60 ft.) cable
30 m (100 ft.) cable
50 m (165 ft.) cable
80 m (260 ft.) cable
100 m (325 ft.) cable
150 m (490 ft.) cable
Special length > 150 m (> 490 ft.)
0
1
2
3
4
5
6
7
8
9
Explosion protection certification
General purpose (non-Ex design)
FM Class 1 Div. 2
usFMc Class 1 Div. 2
ATEX / IECEx Zone 2, 21 & 22
A
G
P
M
Protection class transmitter / protection class sensor
IP67 (NEMA 4X) / IP67 (NEMA 4X) – integral
IP67 (NEMA 4X) / IP68 (NEMA 6P) – cable not fitted and not potted
IP67 (NEMA 4X) / IP68 (NEMA 6P) – cable fitted and potted
1
2
3
Cable conduits *
M20 x 1.5 (plastic)
NPT 1/2in. (blanked when cable not fitted)
M20 SWA (armored)
M20 SWA sensor, M20 x 1.5 (plastic) power / output
Without
A
B
D
F
Y
Power supply
Without
100... 230 V AC, 50 Hz
24VACor24VDC,50Hz
100... 230 V AC, 60 Hz
24VACor24VDC,60Hz
Others
0
1
2
3
4
9
Input and output signal type
HART + 20 mA + pulse + contact output
PROFIBUS DP RS485 physical layer + pulse + contact output (general-purpose design only)
MODBUS RTU RS485 physical layer + pulse + contact output (general-purpose design only)
Without
A
G
M
Y
Configuration type / diagnostics type
Without
Factory defaults / standard diagnostics
0
1
Continued on next page…
* The type of signal cable supplied (standard or armored) depends on the type of cable conduit (variant digit number 24) ordered.
For FM or FMC Approved versions, NPT only permitted.
Product coding field number 1 … 5 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27
Options
Flowmeter system, optimized full bore, integral mount FEV11
X XXX XXXX XX X XXXXXXXXXXX
Flowmeter system, optimized full bore, remote mount FEV12
Optimized full bore sensor only, for use with WaterMaster
transmitter / remote FEV18
WaterMaster
Electromagnetic flowmeter
42 DS/WM–EN Rev. U
Options**
Accessories
Configuration lead AC
Documentation language
German
Italian
Spanish
French
English
M1
M2
M3
M4
M5 (default)
Chinese
Swedish
Finnish
Portuguese
Danish
Norwegian
M6
M7
M8
MA
MF
MN
Other usage certifications
Measuring Instruments Directive (MID)
OIML R49 Calibration
CM1
CM2
Verification type
Without fingerprint
VeriMaster
V0
V3
Potable water approval
WRAS cold water approval
NSF 61 meter approval
DVGW
ACS
Without
CWA
CWC
CWD
CWF
CWY
Power supply frequency (sensor FEV18 only)
50 Hz
60 Hz
F5
F6
Number of testpoints
1 Point
3 Points
T1
T3
**Add codes for options.
Product coding field number 1 … 5 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27
Options
Flowmeter system, optimized full bore, integral mount FEV11
X XXX XXXX XX X XXXXXXXXXXX
Flowmeter system, optimized full bore, remote mount FEV12
Optimized full bore sensor only, for use with WaterMaster
transmitter / remote FEV18
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 43
Electromagnetic flowmeter WaterMaster FEF12 and FEF18
Product coding field number 1 … 5 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27
Options
Flowmeter system, full bore, remote mount FEF12 X XXX XXXX XX X XXXXXXXXXXX
Full bore sensor only, for use with WaterMaster transmitter / remote FEF18
Design
Non-hazardous areas
Hazardous areas (DN700 [27 in. NB])
1
5
Bore diameter
DN250 (10 in.)
DN300 (12 in.)
DN350 (14 in.)
DN375 (15 in.)
DN400 (16 in.)
DN450 (18 in.)
DN500 (20 in.)
DN600 (24 in.)
Others
250
300
350
375
400
450
500
600
999
Liner material
Elastomer – DN250 to 600 (10 to 24 in. NB)
Hard rubber – DN250 to 600 (10 to 24 in. NB)
Other
K
H
Z
Electrode design
Standard
Others
1
9
Measuring electrodes material
Stainless steel 316
Hastelloy®C-22
Super-austenitic steel (DN250 to 600 [10 to 24 in. NB])
Others
S
C
U
Z
Grounding accessories
Standard
One potential equalizing ring (stainless steel)
Two potential equalizing rings (stainless steel)
Others
1
3
4
9
Process connection type (refer to pages 35 to 33)
Flanges ASME B16.5 class 150
Flanges ASME B16.5 class 300
Flanges AWWA C207 class B
Flanges AWWA C207 class D
Flanges AS 4087 PN21
Flanges AS 4087 PN16
Flanges AS 4087 PN14
Flanges AS 2129 Table F
Flanges AS 2129 Table E
Flanges AS 2129 Table D
Flanges AS 2129 Table C
Flanges AS 2129 Table H
Flanges AS 4087 PN35
Flanges JIS G5527 7.5K
Flanges JIS B2220 10K
Flanges JIS B2220 5K
Flanges ISO / EN PN6
Flanges ISO / EN PN10
Flanges ISO / EN PN16
Flanges ISO / EN PN25
Flanges ISO / EN PN40
Others
Note. DN80 to 200 (3 to 10 in. NB) available only with PN16
A1
A3
C1
C2
E0
E1
E2
E3
E4
E5
E6
E7
E8
J0
J1
J2
S0
S1
S2
S3
S4
Z9
Process connection material
Carbon steel flanges
Others
B
Z
Usage certifications
Standard 1
Calibration type
Class 2 calibration – standard accuracy 0.4 %
Class 1 calibration – high accuracy 0.2 %
Extended range, class 1 calibration – high accuracy 0.2 %
Extended range, class 2 calibration – standard accuracy 0.4 %
A
B
N
P
Continued on next page …
WaterMaster
Electromagnetic flowmeter
44 DS/WM–EN Rev. U
Temperature range installation / ambient temperature range
Standard design / –20 … 60 °C (–4 … 140 °F) 1
Nameplate
Adhesive A
Signal cable length and type*
Without signal cable
5 m (15 ft.) cable
10 m (30 ft.) cable
20 m (60 ft.) cable
30 m (100 ft.) cable
50 m (165 ft.) cable
80 m (260 ft.) cable
100 m (325 ft.) cable
150 m (490 ft.) cable
Special Length > 150 m (> 490 ft.) (and / or armored cable)
0
1
2
3
4
5
6
7
8
9
Explosion protection certification
General purpose (non-Ex design) A
Protection class transmitter / protection class sensor
IP67 (NEMA 4X) / IP68 (NEMA 6P) – cable not fitted and not potted
IP67 (NEMA 4X) / IP68 (NEMA 6P) – cable fitted and potted
2
3
Cable conduits**
M20 x 1.5 (plastic)
NPT 1/2in. (blanked when cable not fitted)
M20 SWA (armored)
M20 SWA sensor, M20 x 1.5 (plastic) power / output
Without
A
B
D
F
Y
Power supply
Without
100... 230 V AC (50 Hz)
24VACor24VDC(50Hz)
100... 230 V AC (60 Hz)
24VACor24VDC(60Hz)
0
1
2
3
4
Input and output signal type
HART + 20 mA + pulse + contact output
PROFIBUS DP RS485 physical layer + pulse + contact output (general-purpose design only)
MODBUS RTU RS485 physical layer + pulse + contact output (general-purpose design only)
Without
A
G
M
Y
Configuration type / diagnostics type
Without
Factory defaults / standard diagnostics
0
1
Options***
Accessories
Configuration lead AC
Documentation language
German
Italian
Spanish
French
English
M1
M2
M3
M4
M5 (default)
Chinese
Swedish
Finnish
Portuguese
Danish
Norwegian
M6
M7
M8
MA
MF
MN
Verification type
Without fingerprint
VeriMaster
V0
V3
Potable water approvals
WRAS cold water approval
NSF 61 meter approval
DVGW
ACS
WRAS 60 °C (140 °F) water approval
Without
CWA
CWC
CWD
CWF
CWK
CWY
Power supply frequency (sensor FEF 18 only)
50 Hz
60 Hz
F5
F6
Number of testpoints
1 Point
3 Points
T1
T3
*Size is dependent on flange specification
**The type of signal cable supplied (standard or armored) depends on the type of cable conduit (variant digit number 24) ordered – for FM or FMC Approved versions, NPT only permitted.
***Add codes for options.
Product coding field number 1 … 5 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27
Options
Flowmeter system, full bore, remote mount FEF12 X XXX XXXX XX X XXXXXXXXXXX
Full bore sensor only, for use with WaterMaster transmitter / remote FEF18
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 45
Electromagnetic flowmeter WaterMaster – FEW31, FEW32 and FEW38
Product coding field number 1 … 5 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27
Options
Flowmeter system – full bore, integral mount FEW31
X XXX XXXX XX X XXXXXXXXXXX
Flowmeter system – full bore, remote mount FEW32
Full bore sensor only – for use with WaterMaster
transmitter / remote FEW38
Design
Non-hazardous areas
Hazardous areas
1
5
Bore diameter
DN10 (3/8in.)
DN15 (1/2in.)
DN20 (3/4in.)
DN25 (1 in.)
DN32 (11/4in.)
DN40 (11/2in.)
DN50 (2 in.)
DN65 (21/2in.)
DN80 (3 in.)
DN100 (4 in.)
DN125 (5 in.)
DN150 (6 in.)
DN200 (8 in.)
DN250 (10 in.)
DN300 (12 in.)
DN350 (14 in.)
DN400 (16 in.)
DN450 (18 in.)
DN500 (20 in.)
DN600 (24 in.)
DN700 (28 in.)
DN750 (29 in.)
DN760 (30 in.)
DN800 (32 in.)
DN900 (36 in.)
DN1000 (40 in.)
DN1050 (42 in.)
DN1100 (44 in.)
DN1200 (48 in.)
DN1350 (54 in.)
DN1400 (56 in.)
DN1500 (60 in.)
DN1600 (64 in.)
DN1650 (66 in.)
DN1800 (72 in.)
DN1950 (78 in.)
DN2000 (80 in.)
DN2100 (84 in.)
DN2200 (88 in.)
DN2400 (96 in.)
Others
010
015
020
025
032
040
050
065
080
100
125
150
200
250
300
350
400
450
500
600
700
750
760
800
900
001
051
101
201
351
401
501
601
651
801
951
002
102
202
402
999
Liner material
PTFE – DN10 to 600 (3/8to 24 in. NB)
Hard rubber – DN40 to 2400 (11/2to 96 in. NB)
Elastomer – DN40 to 2400 (11/2to 96 in. NB)
A
H
K
Electrode design
Standard
Other
1
9
Measuring electrodes material
Hastelloy®C-4 (2.4610)
Stainless steel 316Ti/316L
Hastelloy C-22
D
S
C
Grounding accessories
Not required
Standard
One potential equalizing ring (stainless steel)
Two potential equalizing rings (stainless steel)
0
1
3
4
Continued on next page…
WaterMaster
Electromagnetic flowmeter
46 DS/WM–EN Rev. U
Process connection type (refer to pages 21 to 26)
Flanges ASME B16.47 series B / B16.5 Class 150
Flanges ASME B16.47 series B / B16.5 Class 300
Flanges ASME B16.47 series A Class 150
Flanges ASME B16.47 series A Class 300
Flanges AWWA C207 Class B
Flanges AWWA C207 Class D
Flanges AWWA C207 Class E
Flanges AWWA C207 Class F
Flanges JIS 10K
Flanges JIS 5K
Flanges AS 4087 PN 16
Flanges AS 2129 Table E
Flanges AS 2129 Table D
Flanges AS 4087 PN 35
ISO 7005, DIN, EN 1092-1 PN6
ISO 7005, DIN, EN 1092-1 PN10
ISO 7005, DIN, EN 1092-1 PN16
ISO 7005, DIN, EN 1092-1 PN25
ISO 7005, DIN, EN 1092-1 PN40
A1
A3
B1
B3
C1
C2
C3
C4
J1
J2
E1
E4
E5
E8
S0
S1
S2
S3
S4
Process connection material
Carbon steel flanges
Stainless steel flange
B
D
Usage certifications
Standard (without PED) 1
Calibration type
Class 2 calibration – standard accuracy 0.4 %
Class 1 calibration – high accuracy 0.2 %
A
B
Temperature range installation / ambient temperature range
Standard design/ –20 … 60 °C (–4 … 140 °F) 1
Nameplate
Adhesive A
Signal cable length and type
Without signal cable
5 m (15 ft.) cable
10 m (30 ft.) cable
20 m (60 ft.) cable
30 m (100 ft.) cable
50 m (165 ft.) cable
80 m (260 ft.) cable
100 m (325 ft.) cable
150 m (490 ft.) cable
Special length or cable type
0
1
2
3
4
5
6
7
8
9
Explosion protection certification*
General purpose (non-Ex design)
FM Class 1 Div. 2
usFMc Class 1 Div. 2
ATEX / IECEx Zone 2, 21 & 22
A
G
P
M
Continued on next page…
Product coding field number 1 … 5 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27
Options
Flowmeter system – full bore, integral mount FEW31
X XXX XXXX XX X XXXXXXXXXXX
Flowmeter system – full bore, remote mount FEW32
Full bore sensor only – for use with WaterMaster
transmitter / remote FEW38
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 47
Protection class transmitter / protection class sensor
IP67 (NEMA 4X) / IP67 (NEMA 4X) – cable not fitted and not potted to sensor
IP 67 (NEMA 4x) / IP68 (NEMA 6P) – cable not fitted and not potted to sensor
IP 67 (NEMA 4x) / IP68 (NEMA 6P) – cable fitted and potted to sensor
1
2
3
Cable conduits **
M20 x 1.5 (plastic)
NPT 1/2in. (blanked when cable not fitted)
M20 SWA (armored)
M20 SWA sensor, M20 x 1.5 (plastic) power / output
Without
A
B
D
F
Y
Power supply
Without
108.. 230 V AC, 50 Hz
24VACor24VDC,50Hz
100 ... 230 V AC, 60 Hz
24VACor24VDC,60Hz
0
1
2
3
4
Input and output signal type
HART + 20 mA + pulse + contact output
PROFIBUS DP RS485 physical layer + pulse + contact output (general-purpose design only)
MODBUS RTU RS485 physical layer + pulse + contact output (general-purpose design only)
Without
A
G
M
Y
Configuration type / diagnostics type
Not required
Factory default / Standard
0
1
Options***
Accessories
Configuration lead AC
Documentation language
German
Italian
Spanish
French
English
M1
M2
M3
M4
M5 (default)
Chinese
Swedish
Finnish
Portuguese
Danish
Norwegian
M6
M7
M8
MA
MF
MN
Lay length
ISO length – DN10 to 600 (3/8to 24 in.) and 1.25D DN1800 to 2400 (72 to 96 in.)
1.3D DN700 to 2400 (28 to 96 in.) – see dimensional pages 25, 26, 27
1.0D DN700 to 1600 (28 to 64 in.) – see dimensional pages 25, 26, 27
JB
JK
JH
Verification type
Without fingerprint
VeriMaster
V0
V3
Potable water approval
WRAS cold water approval
DVGW
WRAS 60 °C (140 °F) water approval
NSF material approval
Without
CWA
CWD
CWK
CWM
CWY
Power supply frequency (sensor FEW38 only)
50 Hz
60 Hz
F5
F6
* FM approval in process. FEF product still available with full FM approval
** The type of signal cable supplied (standard or armored) depends on the type of cable conduit (variant digit number 24) ordered. For FM or FMC Approved versions, NPT only permitted.
*** Add codes for options.
Product coding field number 1 … 5 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27
Options
Flowmeter system – full bore, integral mount FEW31
X XXX XXXX XX X XXXXXXXXXXX
Flowmeter system – full bore, remote mount FEW32
Full bore sensor only – for use with WaterMaster
transmitter / remote FEW38
WaterMaster
Electromagnetic flowmeter
48 DS/WM–EN Rev. U
WaterMaster FER reduced-bore sensor flowmeter series
Product coding field number 1 … 6 7…9 10 11 12 13 14,15 16 17 18 19 20 21 22 23 24 25 26 27
Options
WaterMaster system. Reduced-bore sensor with remote mounted
transmitter FER121
XXX X XXXXXXXXXXXXXXXXXWaterMaster system. Reduced-bore sensor with integral transmitter FER111
WaterMaster reduced-bore sensor only, remote mount, without
transmitter FER181
Bore diameter
DN 40 (11/2in.)
DN 50 (2 in.)
DN 65 (21/2in.)
DN 80 (3 in.)
DN 100 (4 in.)
DN 125 (5 in.)
DN 150 (6 in.)
DN 200 (8 in.)
DN 250 (10 in.)
DN 300 (12 in.)
DN 350 (14 in.)
DN 375 (15 in.)
DN 400 (16 in.)
DN 450 (18 in.)
DN 500 (20 in.)
DN 600 (24 in.)
040
050
065
080
100
125
150
200
250
300
350
375
400
450
500
600
Liner material
Elastomer – DN40 to 600 (11/2to 24 in. NB) K
Electrode design
Standard 1
Measuring electrodes material
Stainless steel 316
Super austenitic steel (1.4529)
S
U
Grounding
accessories
1 x Stainless steel equalizing ring
2 x Stainless steel equalizing rings
3
4
Process connection type (refer to pages 30 and 30)
Flanges ANSI / ASME B16.5 / 16.47 series B Class 150
Flanges AWWA C207 Class E
Flanges JIS 7.5K
Flanges JIS 10K
Flanges AS 4087 PN 21
Flanges AS 4087 PN 16
Flanges AS 4087 PN 14
Flanges AS 2129 Table F
Flanges AS 2129 Table E
Flanges AS 2129 Table D
Flanges AS 2129 Table C
ISO 7005 PN 10 EN 1092-1
ISO 7005 PN 16 EN 1092-1
ISO 7005 PN 40 EN 1092-1
(40 / 50 / 80 / 100 / 150 … 300)
(40/50/80)
(100 / 150 … 300)
(40 / 50 / 80 / 100 / 150 … 300)
(50 / 80 / 100 / 150 … 600)
(50 / 80 / 100 / 150 … 350 / 450 … 600)
(40 / 50 / 80 / 100 / 150 … 600)
(40 / 50 / 80 / 100 / 150 … 600)
(40 / 50 / 80 / 100 / 125 / 150 … 600)
(40 / 50 / 80 / 100 / 150 … 300)
(40 / 50 / 80 / 100 / 150 … 300)
(40 … 600)
(40 … 600)
(40)
A1
C3
J0
J1
E0
E1
E2
E3
E4
E5
E6
S1
S2
S4
Process connection material
Carbon steel B
Usage certifications
Standard 1
Continued on next page…
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 49
See previous page
Calibration type
Class 2 calibration – standard accuracy 0.4 %
Class 1 calibration – high accuracy 0.2
Extended range, class 1 calibration – high accuracy 0.2 %
Extended range, class 2 calibration – standard accuracy 0.4 %
A
B
N
P
Installation temperature range / ambient temperature range
Standard design –20 … 60 °C (–4 … 140 °F) 1
Name plate
Adhesive label A
Signal cable length and type
Without signal cable
5 m (16.4 ft)
10 m (32.8 ft)
20 m (65.6 ft)
30 m (98.4 ft)
50 m (164.0 ft)
80 m (262.5 ft)
100 m (325 ft)
150 m (490 ft)
Others
0
1
2
3
4
5
6
7
8
9
Explosion protection certification
General purpose
(non-Ex design)
A
Protection class transmitter / protection class sensor
IP67 (NEMA 4X) / IP68 (NEMA 6P) – cable not fitted and not potted
IP67 (NEMA 4X) / IP68 (NEMA 6P) – cable fitted and potted
2
3
Cable conduits*
M20 x 1.5
NPT 1/2in (blanked when cable not fitted)
M20 SWA armored (FEV121 and FEV181 only)
M20 SWA sensor, output and power connector (FEV121 and FEV181 only)
A
B
D
F
Power supply
Without (FEV18 only)
100... 230 V AC, 50 Hz
24VACor24VDC,50Hz
100... 230 V AC, 60 Hz
24VACor24VDC,60Hz
0
1
2
3
4
Input and output signal type
HART + 20 mA + pulse + contact output
PROFIBUS DP RS485 physical layer + pulse + contact output (FEV111 and FEV121 only)
MODBUS RTU RS485 physical layer + pulse + contact output (FEV111 and FEV121 only)
Without (FEV181 only)
A
G
M
Y
Configuration type / diagnostics type
Without (FEV18 only)
Factory defaults / standard diagnostics (FEV11 and FEV12 only)
0
1
Options**
Documentation language
German
Italian
Spanish
French
English
M1
M2
M3
M4
M5 (default)
Chinese
Portuguese
Russian
Danish
M6
MA
MB
MF
Verification type
Without fingerprint
VeriMaster
V0
V3
Potable water approval
WRAS cold water approval
DVGW
ACS
CWA
CWD
CWF
Power supply frequency (sensor FER18 only)
50 Hz
60 Hz
F5
F6
* The type of signal cable supplied (standard or armored) depends on the type of cable conduit (variant digit number 24) ordered.
For FM or FMC Approved versions, NPT only permitted.
**Add codes for options.
Product coding field number 1 … 6 7…9 10 11 12 13 14,15 16 17 18 19 20 21 22 23 24 25 26 27
Options
WaterMaster system. Reduced-bore sensor with remote mounted
transmitter FER121
XXX X XXXXXXXXXXXXXXXXXWaterMaster system. Reduced-bore sensor with integral transmitter FER111
WaterMaster reduced-bore sensor only, remote mount, without
transmitter FER181
WaterMaster
Electromagnetic flowmeter
50 DS/WM–EN Rev. U
Electromagnetic flowmeter transmitter for WaterMaster FET10 and FET12
Product coding field number 1 … 5 678910 11 12 13 14 15
Options
Transmitter module FET10
XXXXXXXXX
Remote transmitter FET12
Design
Non-hazardous area
Hazardous area
1
5
Temperature range installation / ambient temperature range
Standard design / –20 … 60 °C (–4 … 140 °F) 1
Nameplate
Adhesive A
Signal cable length
Without signal cable 0
Explosion protection
Without (transmitter only)
FM Class 1 Div. 2
usFMc Class 1 Div. 2
ATEX / IECEx Zone 2, 21 & 22
Y
G
P
M
Protection class transmitter / protection class sensor
IP67 (NEMA 4X) / IP67 (NEMA 4X) 1
Cable conduits
M20 x 1.5 (plastic)
NPT 1/2in. (blanked when cable not fitted)
M20 SWA (armored)
M20 SWA sensor, M20 x 1.5 (plastic) power / output
Without
A
B
D
F
Y
Power supply
100... 230 V AC
24VACor24VDC
1
2
Input and output
HART + 20 mA + pulse + contact output
PROFIBUS DP RS485 physical layer + pulse + contact output (general-purpose design only)
MODBUS RTU RS485 physical layer + pulse + contact output (general-purpose design only)
A
G
M
Configuration type / diagnostics type
Factory defaults / standard diagnostics 1
Options**
Accessories
Configuration lead AC
Documentation
German
Italian
Spanish
French
English
M1
M2
M3
M4
M5 (default)
Chinese
Swedish
Finnish
Portuguese
Danish
Norwegian
M6
M7
M8
MA
MF
MN
Other usage
Measuring Instruments Directive (MID) CM1
*The transmitter converter module Input and Output Signal Type must match the transmitter backplane output configuration (HART or PROFIBUS) – see OI/FET100-EN.
**Add codes for options.
WaterMaster
Electromagnetic flowmeter
DS/WM–EN Rev. U 51
Common accessories Acknowledgements
Microsoft is a registered trademark of Microsoft Corporation in
the United States and/or other countries
Modbus is a registered trademark of the Modbus-IDA
organization
HART is a registered trademark of the HART Communication
Foundation
Accessory Item Number
WaterMaster AC Fuse F1 Type T 250 mA A/S TR5 B20411
WaterMaster DC Fuse F2 TypeT2AA/STR5 B20412
WaterMaster Infra Red Comms Pack MJBX9932
WaterMaster Backplane PCB Board (STD) WATX2505
WaterMaster Sensor PCB Board WATX2506
WaterMaster Comms Cable WEBC2500
Signal cable for remote WaterMaster transmitter
5 m (15 ft.)
10 m (30 ft.)
20 m (60 ft.)
30 m (100 ft.)
50 m (165 ft.)
80 m (260 ft.)
100 m (325 ft.)
150 m (490 ft.)
500 m (1650 ft.)
STT4500/05
STT4500/10
STT4500/20
STT4500/30
STT4500/50
STT4500/80
STT4500/100
STT4500/150
STT4500/500
Armored signal cable for remote WaterMaster transmitter
5 m (15 ft.)
10 m (30 ft.)
20 m (60 ft.)
30 m (100 ft.)
50 m (165 ft.)
80 m (260 ft.)
100 m (325 ft.)
150 m (490 ft.)
500 m (1650 ft.)
STT4501/05
STT4501/10
STT4501/20
STT4501/30
STT4501/50
STT4501/80
STT4501/100
STT4501/150
STT4501/500
Contact us
DS/WM–EN Rev. U 10.2013
ABB Limited
Process Automation
Oldends Lane
Stonehouse
Gloucestershire GL10 3TA
UK
Tel: +44 1453 826 661
Fax: +44 1453 829 671
ABB Inc.
Process Automation
125 E. County Line Road
Warminster
PA 18974
USA
Tel: +1 215 674 6000
Fax: +1 215 674 7183
ABB Engineering (Shanghai) Ltd.
Process Automation
No. 5, Lane 369, Chuangye Road
201319, Shanghai,
P.R. China
Phone: +86 (0) 21 6105 6666
Fax: +86 (0) 21 6105 6992
Mail:china.instrumentation@cn.abb.com
www.abb.com
Note
We reserve the right to make technical changes or
modify the contents of this document without prior
notice. With regard to purchase orders, the agreed
particulars shall prevail. ABB does not accept any
responsibility whatsoever for potential errors or
possible lack of information in this document.
We reserve all rights in this document and in the
subject matter and illustrations contained therein.
Any reproduction, disclosure to third parties or
utilization of its contents in whole or in parts – is
forbidden without prior written consent of ABB.
Copyright© 2013 ABB
All rights reserved
3KXF211101R1001
Sales
Service
Software

Navigation menu