dormakaba Canada CSC790 Door Lock User Manual Manual

Kaba Ilco Inc. Door Lock Manual

Manual

PK2925-T _11_07 Printed in CanadaKabaIlco Inc.7301 Boul. Décarie Montréal (QC) H4P 2G7Technical Support:1.800.906.4526 Customer Service:T: 1.877.468.3555F: 514.735.6589General Information:www.kabailco.comOnline Consumable Orders:www.keycard.comTo access all of our easy steps,please visit our Support Website: http://connect.kabalodging.comINSTALLATION GUIDEExit Device Operators - Generation E-730 / 630 / 750  / 79E SeriesPK2925-T_11_07E-730 Series 630 Series 750 Series 79E Series
E-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 18Note for Contactless 790 customers: Statement according to FCC part 15.105 This equipment has been tested and found to comply with the  limits  for  a  Class  B  digital  device,  pursuant  to  Part 15 of the FCC Rules. These limits are designed to provide reasonable  protection  against  harmful  interference  in  a residential  installation.  This  equipment  generates,  uses, and can radiate radio frequency energy and, if not installed and  used  in  accordance  with  the  instructions,  may  cause harmful  interference  to  radio  communications.  However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:        receiver. for help. Statement according to FCC part 15.21        void the user’s authority to operate the equipment. Statement according to FCC part 15.19 This  device  complies  with  Part  15  of  the  FCC  Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)  this  device  must  accept  any  interference  received, including interference that may cause undesired operation.
E-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 1731. Re-insert the cylinder plug (Fig. 19)32. While holding the cylinder and plug in place, insert the key33. Turn the key approximately 100º clockwise34. Repeat the steps 1 to 9 to attach the lever handle to the lock  housing. (see Fig. 20)!the latch or deadbolt. Do not use too much force when turning the key as this may damage the unit. To retract the latch, turn the key clockwise until it stops, release the key and turn the lever handle (H). See page 15!Important: Always keep the door open while install-ing and verifying the functionality of the  override. Do not close the door until you are certain that you have installed the unit correctly.!Note: The lever handle must stay in the horizontal position when turning the key (do not try to turn the key while turning the handle) or the override mechanism will not work.Fig. 20Fig. 19Right-handed lockLeft-handed lockHOW TO CHANGE LOCK CYLINDERS (continued)Mechanical Override Models ONLY I CHECKLIST FOR PRECISION EXIT DEVICES 21/22/FL21/FL22  VON DUPRIN 98/99EO-F/9827/9927 EO-F  ** DETEX 10/F10/20/F20E-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 2Each Generation E-730/630/750/79E lockset includes:(A)  Outside lever handle(B)  Outside housing/ Gasket /Adapter plate(C)  Battery holder with 3 AA batteries(D)  Exit Device (Included if ordered with lock operator)Parts inside hardware bag:(E)  4 x Mounting Plate Bushing(F)  2 x Snap Screw Retainer Cup(G)  2 x Washer No.8(H)  2 x Snap Screw Cap(I )  1 x Spanner-head Screw(J)  2 x Mounting Screw (10-24 1/8” Hex)(W)   4 x Flat Washer 1/2 OD X 7/32 ID for Detex Exit Device Only  K/L/M Available for Thin and Thick Doors(K)   2 x Spindle for Precision, Von Duprin and 1 spindle for Detex(L)   2 x Mounting screw (10-24 1/8” Hex)(M )  2 x Mounting Screw (10-24 Pan head Philips)Tools Required:Safety glasses1/4” (6.5mm) drill bit1/2” (13mm) drill bit1” (25mm) drill bit or hole sawDrillAwl or center punchHammer Rubber malletSmall flat screwdriver Philips #2 screwdriverSpanner screwdriver (No 6)1/8” Allen keyAdjustable squareTape measurePencilTapeCleaning supplies (drop cloth, vacuum)©2005 Kaba Ilco, Inc. All trademarks and registered trademarks are the property of their respective owners.AEIBJFHMKDLQCMechanical Override Models ONLY:(N)  Outside Lever Handle(O)  Cylinder Plug(P)   Cylinder (for  630  series  lock  with  cylinders  keyed different ONLY)(Q)  Cylinder CapPONG**   Detex 10 & 20 Series are Panic Hardware only. (Not fire rated)  Detex F10 & F20 Series are Fire Exit Hardware (Fire Rated)WW
E-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 3Target AudiencePlease read and follow all directions carefully. These instructions are designed for use by maintenance profes-sionals or lock installers who are familiar with common safety practices and competent to perform the steps described. Kaba Ilco is not responsible for damage or malfunction due to incorrect installation, that may arise. II INTRODUCTION AND DISCLAIMERSPlease read and follow all directions carefully.!Important: Carefully inspect windows, doorframe, door, etc. to ensure that the recommended procedures will not cause caused by installation.!Caution: Wear safety glasses when making the holes.!  I CHECKLIST FOR STANDARD EXIT DEVICESEach Generation E-730/630/750/79E lockset includes:(A)  Ouside lever handle(B)  Outside housing(C)  Battery holder with 3 AA batteries(D)  Inside dress plateParts inside hardware bag:(K)  1 x Spindle(I)   1 x Torx-head screw(J)  3 x mounting screws (10-24, 1/8” hex head)Tools Required:Safety glasses1/4” (6.5mm) drill bit1/2” (13mm) drill bit1” (25mm) drill bit or hole sawDrillAwl or center punchHammer Rubber malletSmall flat screwdriverTorx screwdriver (T-15)1/8” Allen keyAdjustable squareTape measurePencilTapeCleaning supplies (drop cloth, vacuum)221           222              223                  Inside Dress PlatesD  Part #  Manufactured By 061-510221  Arrow  S3808/S1808     S1908/S3908     S1708/S3708061-510222   Von Duprin   9875/9975 EO-F,  Precision   1103/ FL1103061-510223   Yale   7100-36Warnings and ConditionsBACIKJDE-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 1622. The cap has a small groove on one edge (to allow ease of removal) this should be facing down. Insert bottom snap of cap (I, see page 11) in handle hole below the cylinder. With a small screwdriver, push top snap of cap down while pushing the cap into place to cover the keyhole (Fig. 15)23. To remove the cap, insert a small flat screwdriver into this groove and gently pry the cap off, being careful not to damage it. (You may want to cover the bottom of the lever to protect the finish from being scratched through the process of removing the cap). (Fig.16)19. With the door open, insert key in cylinder and turn it clockwise  until it stops.20. Let go of the key and turn the lever handle (clockwise for  right-handed and counter-clockwise for left-handed locks). The latch must retract.21. Extend deadbolt and repeat the above operation (turn key clockwise until it stops), latch and deadbolt must retract completely.Test the Mechanical Override Function (continued)! lock is installed on the door:Fig. 16COVER THE KEYHOLE & CYLINDER WITH THE CAP9.HOW TO CHANGE LOCK CYLINDERS10.Fig. 1724. Remove the cap from the lever handle (see step 20, Fig. 16).25. Insert key.26. Turn the key clockwise until it stops. 27. Release key.28. Use a small flat screwdriver to push in the lever catch through  the small hole underneath the lever handle (Fig. 17).29. Pull the lever handle off of the lock housing (be careful not to  lose the cylinder plug).30. Replace the old cylinder with the new one in the lever handle. Only same kind of cylinder with 2 grooves in cross, in the end of the cylinder plug could be used on the E-730/630 Series locks. (Fig. 18)Fig. 18 2 Grooves in crossFig. 15(I)Hole below cylinderBottom snap (First)Top snap (Second)Push (Third)
E-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 1513. Turn the handle clockwise (for a right-handed lock) or counter-clock-wise (for a left-handed lock)14. Release the handle slowly. It should return freely to its horizontal  position. (Fig.11)15. If the handle doesn’t easily return to its original position, the spring washer is probably too tight. Use a rubber mallet to hit the lever carefully against the housing to reduce the tension of the spring washer, until the handle moves freely back to its horizontal position when turned slowly.10. Remove key11.  Insert a small flat screwdriver (tool T, page 11) into the  hole on the underside of the lever handle and push in the lever catch.12. Pull on the lever handle. You should not be able to remove the lever handle. If it comes off of the housing, you did not assemble the lock correctly. Return to steps 2, 3, 4 & 5 and make sure that the lever looks like Fig. 10 and repeat this verification process. (Step 6)!correctly attached to the housing: Fig. 1116. Without using the key, turn the lever handle clockwise (for  Right-handed locks) or counter-clockwise (for Left-handed locks). The  inside drive hub should not rotate when the handle turns. (Fig. 12)17. With the lever handle in the horizontal position, insert the key into the cylinder and turn it clockwise until it stops. (This applies to both Right and Left-handed locks, see Fig.13) 18. Let go of the key, and again turn the lever handle clockwise (for Right-handed locks) or counter-clockwise (for Left-handed locks). Now  the inside drive hub should rotate in the same direction as the lever  handle when it is turned. (Fig. 14)!* This test can only be performed when the lock  Fig. 13Fig. 14inside drive hub rotates fig. 12inside drive hub does not moveVERIFY THE ATTACHMENT OF THE LEVER HANDLE6. TEST THE MECHANICAL OVERRIDE FUNCTION8.TEST THE MOVEMENT OF THE LEVER HANDLE(without the key in cylinder)7.the manufacturer’s instructions. **  Detex 10 & 20 Series are Panic Hardware only (Not Fire Rated) Detex F10 & F20 Series are Fire Exit Hardware (Fire Rated)Drill from both sides of the door to prevent unsightly damage. Refer to template for drill sizes and depths.!1   Prepare the DoorMark the desired handle height on the edge of the door. Consult the exit device manufacturer’s instructions for the correct backset. The paper templates are designed for a backset of 2 34” has a different backset. If the door has no bevel, fold the template along the solid lines. Align the fold with the edge of the door, and mark the holes for the lock. Repeat on other side.If the door has a 3º bevel, fold and align the dashed line marked “H” with the higher-beveled edge of the door, and mark the lock holes on that side of the door. Repeat on the side with the lower-beveled edge, using the dashed line marked “L”.Mounting Hole Profile (See Fig.1.1) for:For each of the four (4) type A holes, drill a 1/4” (6.5mm) diameter hole through the door (from both sides, see note below). Enlarge the hole on the outside of the door to a diameter of 1/2” (12.5mm), to a depth of 11/8” (28.5mm). For the two (2) type B holes, drill a 1/2” (12.5mm) diameter hole through the door (from both sides, see note below).Remove the template, then drill the holes for the E-730/630/750/79E lock  (spindle  and  mounting  screws).  For  each  of  the  three  (3) E-730/630/750/79E  lock  mounting  screws,  drill  a  1/4”  (6.5mm) diameter  hole  through  the  door  (from  both  sides,  see  note  below). Enlarge  the  hole  on  the  outside  of  the  door  to  a  diameter  of  1/2” (12.5mm), to a depth of 5/8” (16mm) to receive the screw posts on the E-730/630/750/79E lock. Counter-sink the holes on the inside of the door to receive the heads of the mounting screws, as indicated on the template.Drill the  holes in the door required  for the exit device according to the  manufacturer’s instructions. III INSTALL THE E-730/630/750/79E LOCK AND THE EXIT DEVICEE-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 4Respect all applicable building codes regarding the the positioning of the panic bar.!Standard Mounting Hole Profile5 ”ø12”ø14”ø14”OutsideFig. 1.2Fig. 1.1InsideDoorMounting Hole Profile for:Type A 4 holes requiredType B 2 holes required3 holes requiredø12”OutsideInsideDoorø12”OutsideInsideDoorType BType A1 1”2  Install the Mortise (if applicable)
4   Install the Standard Exit Device and StrikeFollow the manufacturer’s  instructions  to install the  exit  device and an appropriate  strike.  The  Kaba  dress  plate  is  installed  between  the  exit device and the door to conceal the E-730/630/750/79E lock mounting screws. Refer to page 3 for the part number and correct orientation of the available dress plates. Outdoor GasketNotchE-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 5 III INSTALL THE E-730/630/750/79E LOCK AND THE EXIT DEVICEInstall the gasket on the outside housing prior to assembly, aligning the notch in the gasket with the location of the battery compartment.3   Install the Standard Exit Devices E-730/630/750/79E Outside HousingInsert the slotted end of the spindle (K) into the outside lever hub until it locks, at the correct angle for the exit device (see figure). The spindle can be removed by pulling on it, and re-inserted if oriented incorrectly. Place the outside housing on the door and fasten it using the three 10-24, 1/8” hex head mounting screws (J).Spindle Position Yale  ArrowPrecisionKJE-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 14Countersink in TOP PositionCountersink in BOTTOM PositionHit the lever carefully with a rubber mallet to loosen the spring washer. (you may want to cover the lever handle with a cloth or other material to protect the finish of the metal)9. Remove the key. The lock will look as shown in Fig.10.Gently check the rotation of the lever handle. It should easily rotate approximately 45º. Troubleshooting:Right-handed Lock: Turn the lever handle clockwise without forcing it. If it stops at approximately 15º, it was not assembled correctly as shown in step 4 (Fig. 6 & 7). Do not try to force it to turn. Release the lever handle. Insert the small screwdriver (T, page 11) into the small hole on the underside of the lever handle and push in the lever catch.  Re-do steps 2, 3, 4 & 5.Left-handed Lock: Turn the lever handle counter-clockwise without forc-ing. The drive hub (Fig.12 page15) should not rotate when the lever handle is turned. If it does, it was not assembled correctly as shown in step 4 (Fig. 6 & 7). Release the lever handle. Insert the small screw-driver (T, page 11) into the small hole on the underside of the lever handle and push in the lever catch. Re-do steps 2, 3, 4 & 5. right-handed lockleft-handed lockFig. 10!If it is not possible to turn the key counter-clockwise  to complete this step, the spring washer (D, see page 14) may be too tense:ATTACHING THE LEVER HANDLE TO THE LOCK 5. 7. Fit the lever handle onto the drive tube. It should rest approximately 1/16” from the body of the housing. (See Fig. 8)If it can’t be pushed that close to the housing, the lever catch is  probably not pushed in. Push it in. If the lever catch is stuck, the override shaft is in the wrong position.  The two small indents on the cross of the override shaft must be  vertically aligned as in fig. 28. Press the lever firmly against the housing while turning the key  counterclockwise (this applies to both right-handed and  left-handed locks) until it is in the horizontal position. (Fig. 9) right-handed lockleft-handed lockFig. 8Fig. 9right-handed lockleft-handed lock
E-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 133.  Insert the cylinder into the lever handle (see Fig.3)4. Put the cylinder plug into the lever (see Fig.4) 5. Making sure that the cylinder plug does not fall out, insert the key  into the cylinder. The key will be horizontal. (See Fig. 5). Fig. 3Fig. 5Fig. 4!PREPARING THE LEVER HANDLE AND  CYLINDER FOR INSTALLATION3.6. Right-handed Lever handle: Turn the key aprroximately 90º to 100º  clockwise so that it is in the vertical position and the countersink is in  the top position. (See Fig. 6)Left-handed lever handle: Turn the key approximately 90º to 100º  clockwise so that it is in the vertical position and the countersink is  in the bottom position. (See Fig. 7)Troubleshooting:If you have assembled the lever and housing with the key in the wrong position, the key will get stuck. To remove the key, turn it so that it is in the vertical position and insert a small flat screwdriver Catch in (see page15 Fig.2). Remove key. If it is still stuck, turn the in again with the small screwdriver. Remove key.!The key and the countersink must be in the positions shown   or the lever and the override mechanism will not work.Fig. 6countersink in the top positionFig. 7countersink in the bottom positionSTEPS TO ATTACH THE LEVER HANDLE TO  THE LOCK HOUSING *NOTE: 4.E-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 6Mounting for:     and  4   Install the Outside Housing and the Precision 21/22/FL21/FL22; Von Duprin 98/99EO-F/9827/9927 EO-F; ** Detex 10/F10/20/F20 Exit Device and StrikeInsert the slotted end of the spindle (E) into the outside lever hub until it locks.Ensure spindle is oriented as shown (Fig.A). The spindle can be removed by pulling on it and re-inserted if oriented incorrectly. Place the Outside Housing/Gasket/Adapter  Plate  Assembly  on  the  door  and  secure  this assembly to the Exit Device Chassis by using 6 mounting screws (J,L,M).First, fasten the mounting screws (J) into the posts of the Adapter Plate. Next,  insert 2 Mounting Plate Bushings (E) into the holes located at the bottom of the Adapter Plate. For Detex Exit Device ONLY use 4 flat wash-ers (W). Secure this section of the assembly to the Exit Device Chassis by using the proper type of Mounting Screws (L).Secure the top of the Adapter plate to the door by using the 2 Pan Head Mounting Screws (M) and the Mounting Plate Bushings (E). To secure the top portion of the Adapter plate, first pre-assemble the Pan Head Mounting Screws (M) with the Washer (G) and then the Snap Screw Retainer (F). Fasten the Pan Head Mounting Screws (M) to the Mounting Plate Bushing (E), then install the Snap Screw Cap (H). Follow the manufacture’s instruc-tion to complete the installation of exit device and the appropriate strike.**  Detex 10 & 20 Series are Panic Hardware only (Not Fire Rated) Detex F10 & F20 Series are Fire Exit Hardware (Fire Rated)Spindle PositionFig. AMLHGFJWWKEE
E-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 7Three AA batteries  should already  be installed in  the battery  holder (C). Insert the battery holder into the outside housing and secure it using the  6-32 X 3/8” spanner drive screw (F).* For Mechanical Override Models refer to page 11.6  Install the BatteriesIf the lock makes a continuous buzzing noise or the red the battery holder for ten seconds, then reinsert it. !Assemble  the  lever  on  the  outside  housing,  in  the  horizontal  rest  position appropriate to the handing of the door as shown. Simply push the lever onto the tube until  it clicks in place. If more force is required to engage the handle, use a rubber mallet. Test the attach-ment of the handle by pulling smartly on it.The lever is field reversible. If the handing is incorrect, insert a small pick or flat screwdriver in the hole in the hub as shown. Gently pry back the spring clip inside the hub, and remove the handle.AB5   Install the Outside LeverAccess Holecutaway viewE-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 122. Push in the lever catch firmly. (see Fig. 2)PREPARING THE OUTSIDE HOUSING FOR THE INSTALLATION OF THE LEVER HANDLE1. Insert the cylinder(D) or equivalent tool into the override shaft and  turn it 90º clockwise so that the two small indents on the cross are  now vertically in line. (Fig.1)(C)(A)(B)(D)Fig. 1 Fig. 2lever catch1. 2. UPON UNPACKING, THE E-730/630/750/79E LOCK HOUSING WITH MECHANICAL OVERRIDE SHOULD LOOK LIKE THE DIAGRAM BELOW WITH:  (A) The small indents on the cross of the override shaft in line horizontally   (B) The nylon washer and the spring washer on the drive tube    (C) The lever catch in the out position   (D) Cylinder and 2 keys for 630 K/C included in the hardware bag!Important: Assemble the lever, cylinder and lock  components before
E-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 11 VIII INSTALLATION OF THE MECHANICAL OVERRIDE ON 730/630/750/79EParts and Tools ListTools Required:(U)  Cylinder (provided with lock) or equivalent    (T)  Small flat scewdriver (less that 1/8”)(A)  Lock housing(B)  Inside drive hub(C)  Nylon washer(D)  Spring washer(E)  Drive tube(F)  Lever catch(G)  Countersink (H)  Lever handle(I)   Cap(J)  Cylinder (K)  Cylinder plug (L)  Override shaftDiagram of lock:Facing view of drive tube: (E)Back(A)(H)(E)(B)(D)(F)(I)(J)(K)(E)(L)(F)(G)(C)E-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 8 IV TEST THE OPERATION OF THE E-730/750/79E LOCK Activate the panic bar. The latch bolt or rod retracts fully. Turn the outside lever downward. The latch bolt or rod does not retract.If  the  latch  bolt  or  rod  retracts,  verify  that  the  batteries  are properly installed.If the lever feels tight (hard to turn, or does not return easily to its horizontal rest position), check the spindle length vs. the door thickness (the spindle may be too long). Check that the slotted end of the spindle is inserted in the lock housing hub, not the exit device.Test  the  lock’s  response  to  keycards:  a  Test  keycard,  a  Grand  Master keycard, and an Emergency keycard. Insert keycards as shown below, with the magnetic stripe facing toward the door and to the left. For 79E, present cards to reader.1  Panic Bar2  Outside LeverA   Test the Lock Before ProgrammingNormal Entry: Use the Test keycard with the reader. The red and green LEDs each flash once and then the green LED flashes for four seconds. Turn the outside lever downward while the green LED is flashing. The latch or rod retracts fully. Release the lever, then turn it again. The latch or first inserting the keycard.B   Lock ProgrammingProgram the lock with its room number or Common Area number (exit devices  are  usually  programmed  as  common  areas,  see  Reference Manual).Use the Grand Master keycard with the reader. The green LED flashes. Turn the outside lever downward while the green LED is flashing. The latch or rod retracts fully and the LED stops flashing after 4 seconds. Release the lever, then turn it again. The latch or rod must not retract again without first inserting the keycard.C   Emergency Keycard AccessUse the Emergency keycard with the reader. The green LED flashes for 4  seconds.  Then,  turn  the  outside  lever  downward.  The  latch  or  rod retracts fully.While  standing  outside the room, close  the  door  and  ensure  that  it is  properly latched. Open the door using the Grand Master keycard using the same procedure.Caution! Perform the following procedures in order, with the door OPEN unless otherwise indicated.!3  Electronics and Card Reader V  PROGRAM THE E-730/750/79E LOCK Program the lock using the FDU and the E-730/750/79E communication cable (see Reference Manual). If this is not a new installation, but a replacement of a single lock, or a group of locks in a property already equipped with the Solitaire system, transfer the security  information from a neighbouring lock to the new lock by using the Reset Addresses function (see Reference Manual). In the case of a replacement lock, resetting the addresses will ensure that all past lost and stolen keycards remain cancelled in the new lock, and will set the addresses for the Section, Floor, Group, Zone and Area sub-master level so that staff keycards in use at the property will have the same pattern of access to the door as before. This step makes the lock replacement transparent, so that the new lock accepts and rejects the same keycards as the old lock.Front
E-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 9 VI OPERATING THE EMERGENCY OVERRIDE If the card reader fails, the E-730/630/750/79E lock can be opened using the FDU (Front Desk Unit). The lock must have been initialized by a valid FDU from the hotel where it is installed (i.e. with the correct internal and external hotel codes), before the electronic override can be used. There are two possible security levels:   IF  an  FDU  with  a  software  version  lower  than  6.5  overrides the lock, the lock audit records only the date and time.High security: IF an FDU with version 6.5 or higher software overrides the lock, the lock audit records the FDU number, the Authorization keycard number, the date and the time.Hardware Required: Minimum Authorization Keycard Required:  Programming Authorization (PA)Steps to activate the E-730/630/750/79E electronic override:1.  Insert  the  communication  cable  into  the  lock.  Wait  2  seconds,  then  connect the cable to serial port A of the FDU.2. Press any key to activate the FDU, then swipe a PA or higher keycard through the FDU. If the green LED on the lock flashes once, disconnect the cable from Serial Port A, wait 2 seconds, and reconnect the cable.  Main Menu:   1 = Keycard   2 = Reset  ?3. Enter 4 to select the Programming Menu, then  press < >.   Program   1 = A lock   2 = Another FDU  ?4. Wait 2 seconds. Enter 1 to select the Lock option, and press < >.   Enter Function   1 = Program Addresses   2 = Reset Addresses  ?5. Enter 6 to select the Override/Reset Time option, then press < >.  Ready to Override   or Reset Time   Strike a key,   or C to quit.6. Wait 2 seconds, then press any key on the FDU to activate the electronic override. The green LED on the lock should light. The following message should appear on the FDU screen immediately or within 2 seconds. Communication Successful   Press any key to continue.8.  Open  the  door.  You  have  only  4  seconds  after  this  message appears to open the door.9. Remove the communication cable from the lock.Some messages on the screen may differ depending on the FDU version, but the menu choices are the same.Front Desk Unit (FDU)FDU to Lock communication cableIf the lock will not respond to any keycard (including the Emergency keycard), there are three options that should be attempted to open the door. In order, they are:     Initialization keycard in the lock, then use the Emergency keycard.2. Use the electronic override feature (requires FDU and communication cable).E-730/630/750/79E SERIES INSTALLATION GUIDE • PK2925-T_11_07Page 10 VII TEST THE OPERATION OF THE 630 LOCK Activate the panic bar. The latch bolt or rod retracts fully. Turn the outside lever downward. The latch bolt or rod does not retract.If  the  latch  bolt  or  rod  retracts,  verify  that  the  batteries  are properly installed.If the lever feels tight (hard to turn, or does not return easily to its horizontal rest position), check the spindle length vs. the door thickness (the spindle may be too long). Check that the slotted end of the spindle is inserted in the lock housing hub, not the exit device.1  Panic Bar2  Outside LeverA  ProgrammingProgram the lock with at least one user, using the Oracode Maintenance Unit. Generate a valid code for this user. (Recommendation: generate a code that starts a day before today and finishes at least one day after installation/testing date, in order to avoid check-in/check-out time  periods)B  Code entry and accessEnter the user code to validate complete lock operation. Verify that the green LED flashes at each key pressed and a longer green LED flashes at the end of the code entry. Turn the outside lever. Make sure the latch bolt  retracts fully. Release the lever, wait for the lock to return to the locked mode (default settings is 5 seconds after unlocking), and then turn the lever again. The latch bolt must not retract after the lock has 15 sec.) after unlocking, without first entering a valid user code.Caution! Perform the following procedures in order, with the door OPEN unless otherwise indicated.!3  Electronic

Navigation menu