dormakaba EAD RMS0002 Module for Time and Attendance Terminal User Manual Integration Manual
Kaba GmbH Module for Time and Attendance Terminal Integration Manual
Integration Manual
Integration Manual for the Kaba HIDiClass RFID Reader Module FCC ID NVI-RMS0002 About this manual Validity This manual describes the MiFare RFID Reader Module into hosts, e.g. KABA B-web 93 00 Addressees This manual is written exclusively for specialists. The descriptions in this manual are intended for personnel trained by the manufacturer. The information in this manual cannot substitute the product training. The contents of this manual is intended for use by the following groups of people: Project manager Project manager who is responsible for the system and entrusted with project planning and realization. Fitter Person specialized in mounting and installation. Person who has an adequate technical training and sufficient experience and who has been authorized by the manufacturer after completing the training on the product. Service technician Specialist for initial set-up and maintenance of the installation. Person who has an adequate technical training and sufficient experience and who has been authorized by the manufacturer after completing the training on the product. Network administrator Realizes the set-up of the device within the network and makes sure that the devices are accessible within the network. Software partner Specialists for connecting the system to the user software by defining operating and booking sequences, programming the customer applications and setting the parameters of the devices. NOTICE! For reasons of device safety, some of the activities might only be carried out by the SERVICE PERSON. Only persons of the groups "Fitter" and "Service technician" have the status of a SERVICE PERSON according to DIN EN 60950-1:2006. Contents and purpose The contents are limited to the assembly and installation of the hardware. ESD (electro static discharge) protective measures CAUTION Danger for electronic components due to electrostatic discharge. Improper handling of printed circuit boards or components can cause damages that lead to complete failures or sporadic errors. During installation and repair of the device, the ESD protective measures must be considered. Please consider the following guidelines before the installation or maintenance of the device: Always carry an ESD antistatic wristband when dealing with electronic components. Connect one part of the wristband with a discharge socket or an unvarnished grounded metal component. This way, static charges are discharged from your body securely and effectively. Only touch the printed circuit boards at the edges. Do not touch the printed circuit board itself or the connector. Place all dismantled components on an anti-static surface or in an anti-static container. Avoid contact between printed circuit boards and your clothing. The wristband only protects the printed circuit boards against electrostatic discharge from the body, but there is still a risk of damage through electrostatic discharge from your clothing. Transport and dispatch dismantled modules only in electrostatically shielded protective bags. Hardware Features Dimensions 100,0 x 50,0 x 10,0 (LxWxH) mm Antenna on board Interface type UART, TTL Reading distance up to 50mm depending on tag Power supply 5 VDC regulated Dimensions: Description The RMs HIDiclass is a RFID Reader/Writer with serial communication interface and one illumination unit for lighting behind a symbol. The illumination module consists of an analog current source, controlled by the Host-System via separate I2C Bus. The RFID carrier frequency is 13,56MHz and the targeted RFID system is HIDiclass (ISO 15693/14443). The carrier frequency is derived from a 27,12 MHz quartz oscillator. Communication from reader to tag is done with ASK (Amplitude Shift Keying), from tag to read with load modulation. Supported RFID data rates are 6.67kbit, 26.69kbit, 106kbit, 212kbit, 424kbit and 848kbit. The Subcarrier frequency is 423.75kHz, 484.28kHz and 847.5kHz. Power is supplied from the Host-System (regulated, current limited 5VDC±5%.) with a maximum current consumption of 550mA. The device is intended to be mounted as a peripheral device via ribbon cable to a Host-system (e.g. KABA B-web 93 00). The RMs HIDiclass includes the HID OEM75 module which has an integrated voltage regulator, Microcontroller and Transceiver. The clock is derived from a 27,12 MHz quartz. The Host-System directly communicates with this HID OEM75 module. Integration into KABA B-web 93 00 Labeling Using a permanently affixed label, the modular transmitter must be labeled with its own FCC identification number, and, if the FCC identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID NVI-RMS0002 or contains FCC ID NVI-RMS0002”. Any similar wording that expresses the same meaning may be used. DECLARATION OF CONFORMITY according to FCC Part 15 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : bowat-cl Create Date : 2011:10:24 10:26:41+02:00 Modify Date : 2012:02:15 12:41:50+01:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2012:02:15 12:41:50+01:00 Producer : Acrobat Distiller 9.0.0 (Windows) Format : application/pdf Title : Microsoft Word - NVI-RMS0002_RMS HIDiClass_03767_Installation Manual_Draft_sf-24-10-2011 Creator : bowat-cl Document ID : uuid:51a2d7a5-0096-4a0f-83ed-41b1f1eab8b1 Instance ID : uuid:6c29fe4e-e142-4b0c-91ec-11850020a852 Page Count : 7EXIF Metadata provided by EXIF.tools