ePrep EPREP-01 ePrep Sample Preparation Workstation User Manual Instruction manual
ePrep Pty Ltd ePrep Sample Preparation Workstation Instruction manual
ePrep >
Contents
- 1. Instruction manual
- 2. Quick start instructions
- 3. Tablet installation procedure
Instruction manual
ePrep Instructions Important Notes IMPORTANT NOTES ePrep is a new approach to sample preparation and the various liquid handling processes that are required in Analytical Chemistry laboratories. Instructions for operation of the ePrep are available through several mechanisms. The mechanism used for specific instructions Please see the instructions that are shipped with the ePrep: Unpackaging Instructions Quick Start Ready Reference Guide Installation Guide (Software installed on the Computer Tablet supplied. Access this Guide from the Home screen – Systems Quick Start. Scroll through the installation instruction screens. Help Topics available throughout the software that are relevant to the part of the Axis software that is being assessed. This Instruction Manual All are also available at www.eprep.com.au/instructions, except the HELP information imbedded in the software. IMPORTANT ICONS USED IN THESE INSTRUCTIONS Important warning notification for user safety. Biohazard potential Information and hints for operation. Correct hardware and software information Cabling information SUPPLIER Eprep Pty Ltd 14/35 Dunlop Rd Mulgrave, Victoria, 3170 AUSTRALIA (e) info@eprep.com.au (w) www.eprep.com.au (p) +61-(0)3-9574 3600 FEEDBACK The ePrep team has designed ePrep to be a flexible platform and along with the help from ePrep family of users we want to continue to expand capabilities of the system. We welcome your suggestions for changes and addition of new capabilities. We also appreciate notification of errors in the ePrep software and operation at: suggestions@eprep.com.au For technical assistance and reporting please use : support@eprep.com.au Call +61 3 9574 3600 Or write Bldg 14, 35 Dunlop Road, Mulgrave, Victoria 3170 Australia To learn of the latest news, capabilities and free software updates for ePrep, please check regularly atwww.eprep.com.au. ePrep Instructions - Pub No. 99-10008-01 Rev 01 (Feb 2017) © Copyright 2017, Eprep Pty Ltd 1 Safety and Preparation for Use 1.1 Intended Use The ePrep is designed to bring automation to every laboratory and offers a paradigm shift in sample preparation techniques for most analytical methods. ePrep is primarily designed for Analytical Laboratory sample preparation and liquid handling operations. It is a stand-alone robotic system for processing liquids for analysis and is intended for offline processing. Summary Program complex Workflows and be operational in a few minutes Change rapidly between workflows, making it convenient to use ePrep whether it is a small number of samples being run or a large number. One ePrep can be fast enough to prepare samples for multiple analytical instruments Flexibility on the type of vials and vial racks that are used is possible through the use of Adapter Plates which are specific to the vials and racks being used. Common sample vials and racks are provided for as well as common analytical instrument autosampler racks. Automated syringe exchange system with up to 12 different syringes and tools selectable during a Workflow Positive displacement syringe based liquid handling (not pipette) leading to accurate control of volume while dispensing. Precise flowrate control and high pressures permitting micro separation, membrane and filtering operation Needle based sealed vial operation to guarantee sample integrity and safety Integrated Workflow use of Accessories for complete sample preparation processes ePrep is a flexible platform that is designed to accommodate new techniques and accessories to expand it’s capabilities ePrep is not intended for medical use. 1.2 Safety Precautions WARNINGS Boxed ePrep weight = 120kg and ePrep instrument =65kg. Precautions must be taken when lifting and carrying. Refer to the Unpacking ePrep instructions for handling details. Do not enter the instrument work space or place any part of your body near moving axes during operation. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Good Laboratory Practice (GLP) should be followed when using the ePrep. Refer: 21CFR58, 21CFR58, Directive 2004/9/EC and specific product GLP Directives. Precautions for safe handling of biological specimens are outlined by the Centers for Disease Control and Prevention, http://www.cdv.gov ePrep is fitted with an Emergency Stop Button found at the front right side of the instrument. Pressing the button will cut off all power to the instrument. To reinstate power, rotate the emergency button 90° clockwise. Only approved accessories and consumables can be used with the instrument. Eprep assumes no liability for the customer’s failure to comply with these requirements. Connection cables to external equipment should be less than 3m in total length, preferred length is 1.8m OTHER SAFE HANDLING INFORMATION ePrep incorporates many features designed to mitigate the risk of injury to personnel. However, it is sensible and good laboratory practice to treat the machine with caution and not allow body parts or loose clothing to come into close contact with the ePrep when it is operating. Besides the risk of injury infringement on the machine is likely to cause the workflow to abort. Use only approved syringes with the ePrep. These syringes must only be used with the specific needle type supplied with the syringe. The RFID tag used to identify the syringe should not be changed or interfered with. When handling syringes and µSPEed cartridges care should be taken to avoid injury from the sharp needle. ePrep has been produced using paints and other coatings that are highly resistant to chemical attack but nothing is impervious. Always clean up spills immediately to prevent staining and other damage to the ePrep system and use in a well ventilated area where aggressive vapors are involved. Emergency stop: is a safety requirement to immediately stop ePrep operation and movement. Ensure the Emergency Stop button on the front right side of the instrument is not obstructed by items placed near to it and is easily accessible. ePrep has a battery back up system in case of interruption to the main power supply. Removing mains power to the instrument will not stop the operation of ePrep and render the machine safe. The only way to know the machine is completely disabled is activation of the Emergency Stop button. Do not use the EPREP in a potentially explosive environment or with potentially explosive chemicals. Operate the EPREP at temperatures between 15 °C and 40 °C only and at a humidity of max. 80 % at a temperature up to 31 °C. Care and maintenance: Do not clean the tablet, or any part of the ePrep instrument using acetone or aggressive solutions. Other than approved drip trays, do not allow any liquid to enter the device. 1.3 Sample Hazards When working with laboratory chemicals and biological fluids good safe laboratory practices must be followed. It is expected that ePrep is operated by personnel who are skilled already in safe laboratory practices. When using infectious, radioactive, toxic and other solutions which may pose health risks, please observe the safety precautions laid down for your country. Precautions for safe handling of biological specimens are outlined by the Centers for Disease Control and Prevention, http://www.cdv.gov 1.4 Regulatory Certifications INSTRUMENT INSTRUCTIONS Part Number: 01-01000-01 Name: ePrep Sample Preparation Workstation Model Number: GL950X Made in Australia REGULATORY CONFORMANCE ePrep will be certified to a range of regulatory requirements. Check back towww.eprep.com.au/conformance for the latest approvals. Conformité Européenne (CE) EMC compliance for Europe Federal Communication Commision (FCC) EMC compliance for North America FCC ID: 2AJWG-EPREP-01 Contains FCC ID: T9JRN41-3, IC ID: 6514A-RN413 Industry Canada (IC) EMC compliance IC ID: 21989-EPREP01 Regulatory Compliance Mark (RCM) EMC compliance for Australia, AS/NZS 4417.1 RF (Radio Frequency) Exposure compliance distance: 5cm (from Foot) / 20cm (from back panel) RF (Radio Fréquence) Distance de conformité de l'exposition: 5cm (du Pied) / 20cm ( À partir du panneau arrière) Safety Notifications ePrep is to be used indoors only. Not to be disposed of in landfill garbage. Instrument contains sealed lead battery. This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme à la règlementation Canadienne relative aux flux RSS exemptés de licence. L'opération est soumise aux deux conditions suivantes: (1) Cet appareil ne doit pas provoquer d'interférence; et (2) Cet appareil doit accepter toute interférence, y compris les interférences susceptibles de provoquer un fonctionnement indésirable de l'appareil. 1.5 Service and Repair Contact ePrep via www.eprep.com.au/support or your local ePrep service/distributor for guidance on repairs that can be carried out by the user and repairs that require trained service personnel to carry out the work. 1.6 Information for the User Changes or modifications not approved by ePrep could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 2 Introduction to ePrep 2.1 Specifications INSTRUMENT Part Number 01-01000-01 Description ePrep Sample Preparation Work Station Model Number GL950X DIMENSIONS Instrument Dimensions (LxWxH) 1370mm x 694mm x743mm Required Bench Space 1113mm x 603mm Weight 65kg MECHANICAL SPECIFICATIONS Max travel (X,Y,Z) 945, 365, 200mm Positional accuracy ±0.5mm Positional repeatability ±0.5mm Max speed (X,Y,Z) 600, 300, 100mm/sec Plunger specifications 10.16mm lead, min speed=0.155mm/s, max speed= 170mm/s, Max force = 50N ENVIRONMENT Laboratory Sealed vials, cover not required. Suggest well ventilated and climate controlled environment. If using toxic materials take appropriate safety precautions. Solvent Compitibility Painted surfaces have chemical solvent resistance. Powercoat Interpon Polyester/Epoxy blend - Medium Ketones and Low Acid Voltage 24V, 221W, 9.2A DC Power Pack; 100-240 Volt AC input; Requires IEC C13 power cable, nation specific. Operating range 10 - 35 deg C, 0-80% relative humidity Storage range 5 - 40 deg C, 0-80% relative humidity Operating noise Typical 80dB Altitude ≤2000m Pollution degree PRODUCT SUPPORT Maintenance interval 12 months Spare parts availability 7 years from product obsolescence DECK AND TOOL SPECIFICATIONS Tool Rack Capacity 12 Tools Vial Rack Adapter Plates Interchangeable Adapter Plates available for most sample and autosampler racks (see available Adapter Plates and Tools) Vial Rack Adaptor Plate Positions 16 positions @ 55mm x 330mm, plate size matches vial rack size, eg. Sulepco 50 x 1.5mL autosampler vial rack uses 110mm x 330mm adaptor plate Accessories Adapter Plate Positions 8 positions @ 55mm x 220mm, plate size matches accessory, eg. 10 position reagent station uses 110mm x 220mm adaptor plate COMPATIBLE RACKS, ADATOR PLATES AND TOOLS Software Compatibility Only predefined Tools, Racks and Rack Adapter Plates available. Software predefined for simple Workflow creation. Available Adapter Plates for Sample Racks (ordered separately) BelArtSci Large for 90x13mm, 60x16mm, 40x20mm, 24x25mm and 21x30mm Vials BelArtSci Small for 42x13mm, 30x16mm, 20x20mm, 12x25mm and 6x30mm Vials Supelco 96x6-8mm, 50x11-12mm, 48x15-16mm, 90x17mm, 36x22mm, 50x29mm 96 well microtiter plate Available Adapter Plates for Autosampler Racks Agilent 7683GC, 7693GC, 1100LC, 1120LC, 7693HS Shimadzu AOC20iGC, AOC20sGC, SIL20aLC, Sil30aLC Thermo 3000, Triplus Waters 171plus, WISP Robotic Tool Change ePrep uses syringes and tools with Xchange mechanism for unattended tool change during a Workflow. Available syringes with Xchange Gas Tight Syringes with needles: 100µL, 1mL, 10mL (Supplied) Gas Tight µSPEed Endurance Syringes: 100µL, 500µL and 1mL (Optional for SPE) Available Gripper with Xchange(Optional) Gripper for 2mL to 20mL vials (Optional) IDENTIFICATION TECHNOLOGY Tool Identification RFID with magnet check specific for each tool with stored history. Scanned on setup Rack Identification RFID specific for each rack type. Scanned on setup Vial Identification (Optional) NOTE: Gripper is required for barcode scanning 1&2D Barcode Scanner readable formats include: 1D Symbology's: Code 128, UCC/EAN-128 (GS1-128), AIM 128, EAN-8, EAN13, ISSN, ISBN, UPC-E, UPC-A, Interleaved 2 of 5, ITF-6, ITF-14, Matrix 2 of 5, Industrial 25, Standard 25, Code 39, Codeabar, Code 93, Code 11, Plessey, MSI-Plessey, RSS-14, RSS-Limited, RSS-Expand 2D Symbology's: PDF417, Data Matrix, QR Code WASHING OF SYRINGES AND NEEDLES Wash Station Deck mounted syringe Wash Station. Pump driven with active waste removal. External solvent and waste reservoirs (not supplied) Drip Tray Drain System Drain solvent pumped to waste receptacle. SOFTWARE and CONNECTIVITY Tablet Controller Microsoft Surface Pro (Supplied) Operating System Windows 10 Touch Screen, (English Only) Connectivity Tablet to Instrument USB or Bluetooth Operational Software EPREP Axis Software (English Only) designed for rapid Workflow development Software Updates Free Software and Firmware updates available through Axis software via internet connection Connection ports 3 x Serial comms (RS232) (to be used with shielded cable) 4 x Digital Output (12V, 500mA max, refer ULN2003AD spec sheet) (to be used with shielded cable) 4 x Digital Input (typical 5V @ 5mA, refer TLP291-4 spec sheet) (to be used with shielded cable) 4 x Relay (both NO and NC contacts available per relay, 10A, 250VAC, 30VDC, refer JW1FSN-DC12V spec sheet) Note: ALL PORTS ARE FOR CONNECTION TO SELV CIRCUIT ONLY Status indicator Multicolour status indicator LED showing idle, busy, pause, warning and error states COMPLIANCE Workflow Development History: User, Date/Time Creation, Edits, Saves Data Logged Date/Time, Output ID, Workflow ID, Process User Access Multilevel rights controlled by user login Data Input and Output Report formats in TXT and PDF Compliance CE, FCC, IC, RCM, RoHS, Safety EN 61010, EMC 61326 ACCESSORIES Available Accessories (Optional) Shaker, Direct Detector Interface, Solvent Manifold, µSPEed Cartridge Rack. PACKAGING Recyclable, shock resistant 2.2 Instrument Overview Designed a to bring automation to every laboratory the ePrep Sample Preparation Workstation offers a paradigm shift in sample preparation techniques for most analytical methods. Summary Programming with complex Workflows operational in just minutes Rapid change between workflows for the preparation of analytical samples to feed multiple instruments Adaptor plates allow interchangeably of a variety of common sample and autosampler racks on the instrument deck Automated syringe exchange system with up to 12 different syringes and tools selectable during a Workflow Precise syringe based liquid handling (not pipette) High control of volume and flowrate dispensing Pressure dispensing permitting micro separation, membrane and filtering operation Sealed vial operation to guarantee sample integrity and safety Integrated Workflow use of Accessories for complete sample preparation processes Rotating Foot enabling unique operational function. 2.3 Packing List - Base Product Packing list for Part No.01-01000-01, ePrep Sample Preparation Workstation, GX950X INSTRUMENT ePrep Instrument 24volt power pack Surface Pro Tablet with ePrep Axis software USB Type B shielded cable (ePrep to Tablet connection) Underdeck drip tray Note: Country specific IEC C13 Power Cable for power pack not supplied INSTALLATION TOOLS 3 x Screws for Rear Deck Plates 1 x Calibration Probe ADAPTER PLATES 1 x Wash Station deck plate with installed wash station and tubing 1 x Rear/Right deck plate 3 x Accessories Area Adapter Plates 7 x Adapter Plate for BelArt 3x7 Rack - also used for calibration 1 x Adapter Plate & RFID Tag for Supelco 5x10 Rack RACKS 1 x BelArt 3x7 Rack & RFID Tag for 30mL vials 1 x Supelco 5x10 for 1.5mL vials VIALS 100 x 1.5mL autosampler vials/caps 10 x 30mL vials/caps for with cap/septa SYRINGES 1 x 100µL Syringe, 80mm needle 1 x 1mL Syringe, 80mm needle 1 x 10mL Syringe, 80mm needle SPARES 2 x Septa Piercer 2 x 100µL Needles 2 x 1mL Needles 2 x 10mL Needles Quick Start Instructions Wall Chart 10 2.4 Instrument Serial Number Instrument details including Serial Number can be located on the instrument identification panel on the back of the instrument. Please quote the serial number if logging a service call. Serial Number is used as the Username for Website Login. 2.5 Handling and Unpacking ePrep Handling Precautions Precautions must be taken when lifting and carrying the instrument. Unpacking Boxed ePrep weight > 120kg Use folklift only ePrep instrument is approximately 75kg. Minimum 2 person lift Placing on Bench EPREP instrument is heavy, approx. 75kg Minimum 2 person lift to avoid injury Lift by bending legs, maintain a straight back Use a pallet trolley or other suitable wheeled device, do not carry Trolley instrument to installation location Ensure bench is suitable to support instrument weight Lift instrument , 2 person lift, use recommended lift - see diagram. Lift Points Box Unpacking Instructions Initially the Front and Back panels should be removed as shown below. Comprehensive instructions for unpacking the ePrep will be found inside the box fixed to the shipping container. Alternatively the comprehensive instructions may be found at : www.eprep.com.au/instructions The stainless stell drip tray which is to prevent leakage during use and needs to be installed in the base of the ePrep is located in the lid of the cardboard packaging. 11 Remove Nylon Strapping 1. Nylon Strapping 2. Base Panel Remove front and back panels, then side panels followed by the Accessories Box Remove Drip Tray from the front panel. Remove the support pieces in the number order shown. 12 Finally remove the fianl support pieces to enable the ePrep to be removed from the packaing base. 2.6 Options and Accessories Check at www.eprep.com.au for the latest listing of options and accessories. 13 3 Description of ePrep Features 3.0 Description of Features 3.1 XYZ Axis The X, Y and Z axes are stepper motor driven with continuous position monitoring. As an axis moves the actual position is detected and this actual position is compared with the expected position. At machine start the actual position for each axis has to be established in the software. A software routine moves each axes a few centimeters in either direction to establish the position. Occasionally, when an axis is already at its full extension of travel at machine start up the axis carriage will be heard impacting the its travel limits before reversing direction. Note . this noise maybe alarming but is normal and does not damage the machine. When power is removed from the machine (flat battery or Emergency Stop activated) the axis may be moved manually. 3.2 P-Drive The P-Drive is the heart of the ePrep system with an array of actuators, motors and sensors incorporated. The P-Drive incorporates a separate microprocessor for controlling and monitoring the various functions. Communication between the P-Drive processor and the main Board in the ePrep is via a series of wires and connections across the Z-Y- X axes internconnects. Xchange coupling that automatically connects and disconnects to the syringe barrel and to the syringe plunger. Stepper Motor and encoder to precisely drive the syringe plunger and detect high back pressures and automatically adjust the flowrate. IR sensor that rapidly scans for the presence of vials. Septum piercer. The syringe needle is not used to pierce septa because of the risk of bending the syringe needle. First the piercer punctures the septa and the syringe needle goes through the bore of the piercer into the vial. On withdrawal from a septa, the piercer first retracts leaving the needle in the vial and then the needle is withdrawn, wiping the syringe needle on the inside of the septa. Rotating foot with vertical movement. This rotates to guide the syringe needle into the septa piercer. The foot through which the piercer and syringe needle pass is movable and separately controllable in the Z- plane. It is required to push vials as the syringe needle is withdrawn through the septa, otherwise they would stay attached. At the back of the P-drive is located an RFID reader to detect and receive data on the syringes and tools that are on the Tool Rack. On the opposite of the Foot to the needle piercer and fork is an additional RFID reader to sense and read RFID tags on the Vial Racks and Vial Rack Adapter Plates. Barcode Reader (optional). In conjunction with the Vial Gripper that picks up vials and rotates them. Reads 2D and 3D barcodes. 14 3.3 Senor Foot The sensor foot at the bottom of the P-Drive is a mechanical switch that precisely detects the P-Drive foot touching an external feature. The Sensor Foot is used for the following functions : For safety purposes to detect incorrectly positioned objects or personnel coming into contact. Activation of the Sensor Foot during operation immediately stops all motion of the machine in the same way as the Emergency Stop. A continuous RED indication will be given by the annunciator on the X-axis. At ePrep installation all axes are moved to a range of locations and the Sensor Foot is touched against features on the ePrep deck. The data from this precise calibration process is used in the firmware of the machine to move the move the axes and components of the ePrep to very of the whole platform at ePrep installation. Detects the presence and height of vials by touching the vials. To calibrate the rotation of the foot at the beginning or a workflow. The Sensor Foot rotates against the side of the P-Drive housing. 3.4 Tablet and ePrep Axis Software The ePrep is supplied with a Microsoft Surface Pro tablet computer. Preloaded on this computer is the ePrep Axis software which manages all elements of the monitoring and control of the ePrep. The intensive data communication between the Tablet and the ePrep can be done by Bluetooth connection.. The ePrep has been designed and tested for operation on this computer. Installing the ePrep Axis software onto an alternative computer or different version of operating system is not approved. Axis Software Overview Conventional laboratory automation is designed to define processes by programming specific movements at a very low level. The difference with the ePrep Axis software is programming a workflow is done by selecting standard tasks that are already fully defined in the software and then adjusting parameters. As a high level program it is much easier and faster to create a workflow. For information on operating the ePrep Axis software see the following guides : Quick Start Ready Reference Guide Installation Guide (Software installed on the Computer Tablet supplied. Access this Guide from the Home screen – Systems Quick Start. Scroll through the installation instruction screens. Help Topics available throughout the software that are relevant to the part of the Axis software that is being assessed. This Instruction Manual 15 3.5 Wash Station Installation of the Wash Station is described in the Quick Start Instructions and the “Installation Guide” that is installed on the Computer Tablet. The Wash Station is designed for washing syringe needles to prevent cross contamination and also as a means to empty syringes to waste. Parameters for washing are controlled through the Axis Software. These parameters are available to be defined either in a specific Wash Task in a Workflow or during set up of the Syringe/Tool parameters for a Task such as Aliquoting, Dilution etc. There are two concentric chambers in the Wash Station. The inner small inside diameter tube (Xmm ID) has water or other solvent pumped upwards through the tube. With the syringe needle inserted into this tube there is a high velocity of liquid over the outside of the needle for more effective cleaning. The Wash station can be used to just clean the outside of the needle or wash the inside of the needle and syringe barrel by pumping the solvent into the syringe during washing. This option and other functions for washing are selected when setting the syringe parameters as a Workflow is created in the Axis software. As solvent is pumped up through the inner tube it overflows into the outer cavity which is then pumped to a waste receptacle. When a syringe is being purged of any remaining liquid from an operation, the liquid is disposed of directly into the outer cavity of the Wash Station. Two peristaltic pumps are used in the Wash Station. One pumps the Wash Fluid from the reservoir to the Wash Station and the other pumps the waste from the outer chamber to a Waste bottle. 3.6 Tool Station 12 stations for syringes and other tools that can be coupled to the P-drive via the ePrep Xchange coupling system. Each station is designed to hold the syringe/tool in the correct position for engagement by the Xchange coupling system. On the far left side of the Tool Rack is a Locking Station that the P-drive returns and connects at the completion of a workflow (after disconnecting all tools). The Locking Station is also one of the reference points used to calibrate the ePrep at installation. The correct coupling and decoupling of syringes and tools is the most dimensionally critical aspect of ePrep operation and that the calibration routine checks and corrects for critical position parameters. 3.7 Battery Backup System ePrep is equipped with a 24V DC sealed Lead Acid battery back up system. The system detects the loss of Mains Power and automatically connects to the Battery Back Up. A fully charged Back Up battery provides approximately 20 minutes of uninterrupted operation of the ePrep following failure or removal of the Mains Power supply. If depletion of the Back Up Battery is detected while operating under battery power, the workflow will be terminated, the syringe/tool being used will be returned to the Tool Rack and the P-Drive will return and lock onto the Park station. At resumption of Mains Power the ePrep will automatically switch back to Mains Power and if a WorkFlow is in progress will continue the operation. The Back UP Battery will also be recharged. CAUTION Even with the removal of mains power supply and switching the ePrep OFF at Mains Power, the ePrep will not be disabled and is still capable of moving. There are three ways for an operator to completely disable ePrep from any motion : Activate the Emergency Stop Trigger the Sensor Foot Power switch on the left side rear of the ePrep switched to OFF. Note removing the power cable or switching OFF the Mains power does not disable ePrep as the Back Up Battery will still be active. 16 3.8 Software Updates In the interests of continual improvement, ePrep will be regularly making available free software upgrades. These upgrades will add additional capabilities to ePrep as well as rectifying identified bugs in the software. After ensuring the Computer Tablet has access to the internet click on Home – Service – Software Updates. (should use pictures of the keys here) The software will guide you through the updates available and how to download and install them. Checking for updates can etither be done through the computer tablet. 3.9 Power Supply Note : the ePrep uses a separate 24V DC 221W, 9.2A DC power pack power supply. Input 100V to 240V AC input. The Country Specific Mains Power cable is not supplied with the ePrep. Use a standard Country Specific IEC C13 cable. Note : Ensure the Emergency Stop button on the front right side corner is deactivated by turning the button clockwise. 3.10 Syringes and Tools ePrep syringes and tools are fitted with Radio Frequency Identification (RFID) tags. The code programmed onto each RFID tag is specific to the syringe and is used to positively identify that the correct syringe has been used in a workflow. The capability also tracks and records which syringe has been used for specific sample and the history of the syringe. Only syringes specifically designed for the ePrep may be used on the system with a correctly programmed RFID tag. For the ePrep to correctly pick up a syringe/tool from the tool rack, the device must be correctly positioned. The plunger must be fully down with the Tool retainer Clip sprung fully forward and covering the fully depressed syringe/tool plunger.3shown in the diagram (Fig XX) and pushed all the way back onto the holder. A magnet in the tag holds the syringe back in the correct position. The syringe needle cannot be significantly bent and it must be located in within the Vee in the needle holder. There is also a magnet in the holder to hold the needle in position once it has been located correctly by the operator or the ePrep when it returns a syringe/tool to the rack 3.12 Adapter Plates, Vial Racks and Vials WARNING The ePrep is not quite clairvoyant in knowing the exact location of vials that it must extract and deposit samples. The position of the vials must be precisely defined in the software. The ePrep software has been designed to make it as simple as possible for the operator to accurately define the location of vials in the workflow on the deck. It has also been defined to identify errors in placement of resources on the deck of the ePrep. This is made possible by identifying all racks used on the ePrep with an RFID tag specific to 17 the rack. From the RFID tag on the vial rack or Rack Adapter Plate, the ePrep will identify that a defined rack is present on the deck, even if it is in an incorrect location as defined by the operator. It will also sense and identify if there are vials present or not present and will not try and aspirate from or dispense into locations where a vial is not present. For this level of simplicity and error proofing of ePrep operation it is essential that a few basic guidlelines are followed : 1. A correctly programmed RFID tag must be attached to either the Rack or the Adapter Plate. 2. If the RFID tag is fixed to the Adapter Plate the user needs to ensure that the Vial Rack used matches the defined Adapter Plate. 3. Do not be tempted to use a vial rack with an adapter plate that appears to be right size. Check before use. 4. Before starting a workflow the ePrep software prompts the operator to check that the graphic on the Computer Tablet screen matches the racks and tools that are on the ePrep deck. Be in the habit of always doing this. The consequences of incorrect definition of racks and vial positions are : 1. Incorrect processing of samples and loss of precious samples 2. Damage to the syringe needle and septa piercer 3. Termination of the workflow due to the head crashing into some element on the ePrep deck The sensor (bumper) in the foot of the P-Drive of the ePrep is used for a multitude of functions in the operation of the ePrep. will detect collisions. The task of defining vial positions accurately is made easy for the operator by using vial racks whose coordinates have been mapped by ePrep and are included in the parameters supplied by ePrep. It just needs to be ensured by the user that the correct vial rack has been used and it is being used with the correct Vial Rack Adapter plate for that specific vial rack. If there is a vial and rack combination that is required to be used and it is not currently available in the ePrep software, please contact ePrep at www.eprep.com.au to determine if a new rack can be defined in the software with a suitable adapter plate. To make the task easier, either the Vial Rack Adapter plate or the vial rack itself are fitted with a specific RFID tag. The ePrep reads the RFID tag at the beginning of a process to confirm the correct vials and racks are in the position specified by the user. If the scan detects that a rack is in an incorrect position or is not present the process will be stopped until the user corrects the error. As the ePrep processes a series of vials in a particular rack it will sense if there is a vial missing from where it was defined to be. The software default is to continue onto the next vial in the series and leave the output vial associated with the missing vial and move onto the next process in the workflow. 18 4 Installation 4.1 Quick Start - Commissioning Process The following guide is a step process for the initial set up of the ePrep. See detailed instructions under Quick Start - Installation and Commissioning. STEP #1 - ePrep LOCATION Place ePrep on a clean flat surface with no obstruction to the axis movement. The instrument should be located for simple access to the connectors and emergency stop button. Adjust ePrep feet to level instrument if required. STEP #2 - START TABLET SOFTWARE Power up the Computer Tablet and open the ePrep software via ePrep App icon shown above. Further installation instructions can be found on the Tablet. STEP #3 - PREPARE ePrep DECK See detailed instructions under: Quick Start - Installation and Commissioning STEP #4 - CABLE and POWERUP ePrep See detailed instructions under: Quick Start - Installation and Commissioning STEP #5 - RUN CALIBRATION See detailed instructions under: Quick Start - Installation and Commissioning 19 STEP #6 - INSTALL TOOLS, RACKS and VIALS See detailed instructions under: Quick Start - Installation and Commissioning 4.2 Quick Start - Installation and Commissioning Detailed installation instructions can be found in the PDF attached. Ensure the instruction sequence is followed. Instructions can also be found on the Tablet Software. Installation Procedure - Feb 2017.pdf (1.79MB) 4.3 Workflow Setup WORKFLOW ELEMENTS Please fined enlarged images attached WORKFLOW PARAMETERS 20 Please fined enlarged images attached SAVING A WORKFLOW Please fined enlarged images attached Slide2(700).jpg (212KB) Slide1.JPG (4.37MB) Slide12.JPG (4.17MB) 4.4 Example Workflows Explained 4.4.1 Sequential vs Batch Processing SEQUENTIAL WORKFLOW PROCSSING A series of task is known as a Task Group. Task Groups can be made up of more than one Task to maximise efficiency. For simple Workflows, single task processing completes all the processing of one vial before moving to the next vial. This is typically more time consuming as syringes will be washed between individual tasks to eliminate carry-over. The following EXAMPLE produces 4 output tubes with sample, internal standard and diluent performed sequentially. 21 Workflow Setup BATCH WORKFLOW PROCESSING A quicker and more efficient Workflow is achieved by carrying out a Task on all defined vials before moving to the next task/task series. The following EXAMPLE produces 4 output tubes with sample, internal standard and diluent, each added in a batch processes. Workflow Setup 22 23 4.4.2 µSPEed cartridges Tasks for processing µSPEed cartridges are defined in the ePrep software. Most µSPEed Workflows would also include preparation steps such as addition of internal standard and diluent. The EXAMPLE below demonstrates activation, condition, load and elution of a series of 4 samples using µSPEed cartridges. Workflow Setup 24 4.4.3 Calibration Standards Prep has the ability to create calibration standards by automatically incrementing aliquots of standard concentrate into a series of vials each made up to a standard volume. The following EXAMPLE produces a series of 6 calibration standards from 10µL to 60µL of concentrate, internal standard addition and made up to 1500µL. Workflow Setup 25 5 ePrep Operation 5.1 Introduction to Operation 5.1.1 Instrument Light Status LED Status Indicator Instrument Status No power to the instrument. Check mains, powerpack and emergancy stop button Solid Blue Eprep ready for use Flashing Blue Workflow completed successfully Green Workflow running System will remain green until completion or interruption of workflow Flashing Purple Workflow aborted by user. Check software for options. Orange Workflow paused by user Software provides user ability to continue workflow or abort workflow Red Sensor foot or instrument error Check for obstructions to the rotating foot. Typically items placed on the deck or different height vial placed in a rack along with vials of a lower height. Faults with instrument hardware. See trouble shooting information. White Mains power disconnected. Eprep running on battery power. Battery life approximately 20min 5.1.2 Planning a Workflow 26 5.1.2.1 Sequential vs Batch Processing Sequential Tasks Sequential or serial processing is when Tasks to complete a full workflow on a the first sample are finished before starting the same Tasks on the second sample. Sequential processing is normally slower that batch processing as it typically requires tool changing and syringe washing between Task. However for some applications Sequential processing may be required due to kinetics or post sample processing requiring completion of one sample before proceeding to the next. Batch Tasks Batch processing is where the same Task is preformed on all samples before proceeding onto the next sample. Batch processing is the fasted way to process a group of samples as it eliminates the tool change and washing steps between samples. A Workflow may include both Sequential and Batch Tasks. Sequential and Batch task are identified within a Workflow by grouping Task. A series of grouped Task will be done sequentially. 5.2 Hardware 5.2.1 Syringes 5.2.1.1 Syringe Selection Syringe Selection When selecting a syringe for a Workflow Task, the following tables provide volume ranges for 100µL, 1mL and 10mL syringes. The mimimum dispensed volume has been calculated at 2% of the syringe volume. However, at small dispensed volumes, liquid droplet formation at the tip of the needle must be considered. It is recommended that the needle tip is dipped into the output vial solution to minimise droplet for small volume dispensing. Dispensed Volume Range Selection for ePrep Syringes 27 Dispensed Volume Range Selection for ePrep µSPEed Syringes Maximum Pressure Available using ePrep Plunger Drive Precision and Accuracy: A high level of precision and accuracy can be expacted when the correct syringe is used with ePrep. The plunger drive motor has over 1000 steps per syringe volume. The drive is also capable of very accurate plunger position and speed during dispensing. Carry-over Sample carryover must be carefully considered in a Workflow. ePrep has set default automated wash setting into Workflow Tasks. However the wash settings for different compound classes, that vary in viscosity and stickiness for example, may require changes to these wash settings. Note: Reserpine is often used to check for carryover in LC-MS systems. Priming of Syringe Priming of the syringe can have an effect on both the carryover and precision but over priming can waste reagent and increase the time to complete a workflow. ePrep has set default automated priming into Workflow Tasks. However for sticky or low viscosity liquids priming parmater may need to changes to ensure air bubbles don't form in the syringe barrel. . 28 5.2.1.2 Default Syringe Parameters Maximum Value Auto & Default Aspirate Flowrate (µL/sec) (µL/sec) 50 300 Aspirate Pause (sec) 360 Dispense Flowrate (µL/sec) 300 100 Dispense Pause (sec) 360 Wash Volume (µL) 100 30 Wash Aspirate Flowrate (µL/sec) 1000 20 Wash Aspirate Pause (sec) 360 Wash Dispense Flowrate (µL/sec) 300 300 Wash Dispense Pause (sec) 360 Wash Cycles 100 Wash Air Purge (µL) 10 10 Rinse Time (sec) 360 Prime Volume (µL) 10 15 Prime Aspirate Flowrate (µL/sec) 300 10 Prime Aspirate Pause (sec) 360 Prime Dispense Flowrate (µL/sec) 300 300 Prime Dispense Pause (sec) 360 Prime Cycles 100 Aspirate Flowrate (µL/sec) 1 50 700 Aspirate Pause (sec) 360 Dispense Flowrate (µL/sec) 700 210 Dispense Pause (sec) 360 Wash Volume (µL) 700 100 Wash Aspirate Flowrate (µL/sec) 1000 50 Wash Aspirate Pause (sec) 360 Wash Dispense Flowrate (µL/sec) 700 500 Tool Parameter Minimum Value 100µL Syringe 1mL Syringe 29 Wash Dispense Pause (sec) 360 Wash Cycles 100 Wash Air Purge (µL) 1000 Rinse Time (sec) 360 Prime Volume (µL) 1000 100 Prime Aspirate Flowrate (µL/sec) 700 15 Prime Aspirate Pause (sec) 360 Prime Dispense Flowrate (µL/sec) 700 500 Prime Dispense Pause (sec) 360 Prime Cycles 100 Aspirate Flowrate (µL/sec) 1 150 1000 Aspirate Pause (sec) 360 Dispense Flowrate (µL/sec) 1000 500 Dispense Pause (sec) 360 Wash Volume (µL) 5000 800 Wash Aspirate Flowrate (µL/sec) 1000 150 Wash Aspirate Pause (sec) 360 Wash Dispense Flowrate (µL/sec) 1000 500 Wash Dispense Pause (sec) 360 Wash Cycles 100 Wash Air Purge (µL) 5000 500 Rinse Time (sec) 360 Prime Volume (µL) 5000 1000 Prime Aspirate Flowrate (µL/sec) 1000 70 Prime Aspirate Pause (sec) 360 Prime Dispense Flowrate (µL/sec) 1000 500 Prime Dispense Pause (sec) 360 Prime Cycles 100 10mL Syringe 5.3 Software 30 5.3.1 Overview ePrep Axis Software is designed to quickly create, save and run laboratory sample preparation workflows. Workflow Elements A Workflow consists of four elements; 1) The Task Function 2) Syringe or Tool to perform the fuction 3) Input Vial/Tubes and 4) Output Vial/Tube. Selction of these parameters is shown below. Task ePrep have preprogrammed Task functions to simplify programming of the instrument. Tasks have been designed to mimic common laboratory processes. Tasks are given names related to the laboratory process they replace. Eprep have defined defult parameters for each task which should be suitable for most applications. However the user can modifiy these parameters if required. User cannot create a Task Tools ePrep Tools include syringes, grippers and specific function tools. Tools are predefined in the ePrep software and therefore only Registered or Predefined Tools can be used with ePrep. ePrep uses RFID to identify and record a tool useage of a Tool.. User cannot create a Tool class. Adaptor Plates, Racks and Vials Adaptor Plates and Racks classes are predefined in the ePrep software. Only Registered Adaptor Plate/Racks can be used with ePrep. Inpu/Output vial positions within a rack can be defined in the sofwtare. User cannot create an Adaptor Plate/Rack class. 31 5.3.1.1 Main Menu and Icons Main Menu Options Options to create a new Workflow, Edit a saved Workflow and Run a saved Workflow. Options to Register Racks, Tools and Accessories in the software database. This area is particularly useful when adding previously unregistered assets to the ePrep/ Enables ePrep scanning and user definition of Tools, Racks and Accessory assets for Workflow integration. Options for instrument calibration, software operational settings, user administration and operation/workflow reports Icons Exit software or Return to previous menu depending on the screen context . Contextual help information available throughout the software. Enables user login and options to change user details such as password. Indicates Tablet USB connection to ePrep. When connected USB is established icon will display USB icon. When communication is not established icon will display a cross. Battery charge level indicator. Will display power icon when tablet is connected to mains. It is recommended that during running of an ePrep Workflow that the tablet is connected to the mains Information about installed Software and Firmware versions. This information is important for communication Faults and Software Bug. System also uses this information for automatic software/firmware updates. 5.3.2 Workflow 32 5.3.2.1 Tasks ePrep has been preprogrammed with a series of Tasks designed to mimic typical laboratory sample preparation processes. The following table provides a summary of available Tasks their function and use in a sample preparation Workflow. Task Function and Use µSPEed Wash Washes series of µSPEed cartridges using a single wash vial (vial group). Wash task is used for Activation, Condition and Washing of cartrdiges. µSPEed Load Loads a series of µSPEed cartridges using a series of input vials. Task includes load needle wash and also enables collection of loading sample µSPEed Elute Elutes a series of µSPEed cartridges using a single eluant input vial (vial group) to a series of ouput vials. Aliquote Sample Adds Sample from a series of input vials to a series of output vials. Aliquote Sample Supernatant Adds Supernatant Sample at a nominated depth from a series of input vials to a series of output vials. Add Internal Standard Adds Internal Standard from a single input vial (or vial group) to a series of output vials. Add Surrogate Adds Surrogate Standard from a single input vial (or vial group) to a series of output vials. Add Diluent Adds dilute solution from a single input vial (or vial group) to a series of output vials. Allows syringe mixing Add Reagent Adds a reagent from a single input vial (or vial group) to a series of output vials. Add Reagent and React Adds a reagent from a single input vial (or vial group) to a series of output vials and provides a counter for timing reaction time after reagent is added. Serial Dispense Adds sample/standard from a single input vial (or vial group) with a set starting volume to the first output vial, incrementing the volume for subsequent output vials. Makeup to Volume Used in conjuction with "Serial Dispense", it adds diluent from a single vial (or vial group) to make up to a set volume in the Serial Dispense output vials. Syringe Mix Enables syringe mixing of series of vials. 33 5.3.2.1.1 µSPEed Wash Task Summary Washes series of µSPEed cartridges from an input tube(s) to waste. Wash task can be used for Activation, Condition and Washing of cartridges. Processing Typical Use Used for activation, conditioning and washing µSPEed cartridges though the Workflow Tool Settings and Options Setting Options Volume Increments (µL) Volume inciments (µL) Tool Wash Method Default Syringe wash is to remove carryover. Auto is a predefined syringe wash procedure for a Task. Parameters typically include wash on solution change, before and after syringe park in tool cassette. Always Will wash the syringe after each Workflow step. It also washes before and after syringe pickup from tool cassette. Typically used for Task that include syringe mixing, needle dipping and kinetically sensitive operations. After Pickup Wash of the syringe is limited to after pickup only. Typically used for Tasks where cross contamination is not an issue such as dispensing of the same reagent. Will also improve Workflow times. Never Tyically used for repeated Workflows where a syringe is used to aliquote the same and there is no chance of cross contanimation pre, during and post run. Wash Washing of barrel and needle to eliminate carry over from previous aliquote. Rinse Needle Rinses the outside of the needle only. Typically used when adding reagent or standard and the needle is dipped during dispense. Will eliminate carryover. Auto Wash See Default Table Syringe volume used for washing cycles. It is better to do a large number of small volume washes. Related to dilution factors. Tool Wash Aspiration Flowrate (µL/sec) See Default Table Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples Tool Wash Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Tool Wash Cycles See Default Table Number of wash cycles. Prime Method 34 Auto Tool Wash Volume (µL) Prime Type Prime Settings Description Type increment volume Tool Wash Settings Wash Type Selections Auto Syringe prime is designed to remove airbubbles and ensure syringe is completely filled with the selected solution prior to aspiration. Auto is a predefined prime procedure for a Task and Syringe. It typically includes a prime step if the syringe has before all task aspirations if the syringe has not been prviously primed with the selected solution. Always Enables priming before every Task volume aspiration Never Removes priming process from the Task. To Tube Priming dispense to selected tube/vial To Waste Priming dispense to waste wash station Auto To Tube Prime Volume (µL) Syringe volume set for priming. It is better to do a large number of small volume washes. Related to dilution factors. Prime Aspiration Flowrate (µL/sec) Prime aspiration flowrate should be slow enough to ensure cavitation does not occur Prime Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution. A longer pause is required for larger syringe volumes and high viscosity liquids. Prime Dispense Flowrate (µL/sec) Prime dispense flowrate should be as fast as possible to assist air bubble removal Prime Dispense Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Tool Wash Cycles Number of times plunger is cycled for the wash process 5.3.2.1.2 µSPEed Load Task Summary Loads µSPEed cartridges with sample from a series of input tubes. It includes load, needle wash and also enables collection of loading sample Processing Typical Use Specific function for loading µSPEed cartridges which includes flushing of needle and the ability to collect unretained analytes. Tool Settings and Options Setting Options Volume Increments (µL) Volume inciments (µL) Default Selections Description Type increment volume 5.3.2.1.3 µSPEed Elute Task Summary Elutes a series of µSPEed cartridges from an eluant input tube(s) to a series of ouput tubes. Processing Typical Use µSPEed cartridges elution process includes the ability to nominate output vials Tool Settings and Options Setting Options Volume Increments (µL) Volume inciments (µL) Default Description Type increment volume Rense needles between dispenses (sec) zero Timed needle rinse between dispenses. Typically used if needle is dipped in solution on output vial dispense. Volume to over aspirate (%) zero Over aspiration function to counter system backlash. Draws the plunger past the selected volume by slected %, then dispenses the over aspiration amount back into input vial before dispensing the selected volume into the output vial. Aspirate Needle Position Bottom of the vial Position of the needle during aspiration measured as mm below the septum cap. Used if vial contains sedimant or requires access to supernatent layer. Dispense Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Pre Aspirate Air Gap (µL) zero Aspiration of an air gap over the liquid. Often used to dipense all liquid from the syringe and needle to minimise carryover or avoid prolonged contact with corrosive solvents. Aspirate Flowrate (µL/sec) See Default Table Aspiration flowrate can be varied to compensate for liquid viscosity or process requirements. Plunger drive has a finite velocity and force capability so flowrate range and accuracy is dependent on syringe volume. Aspirate Pause (sec) See Default Table Timed pause after plunger aspiration before dispensing. Pause should be increased with high aspirating plunger speeds or high viscosity liquids are used so liquid head can catch up with the plunger for full volume fill. Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Dispense Pause (sec) See Default Table Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. This results in greater accuracy and reproducibilty. A loner pause is required for larger syringe volumes Settings 35 Selections Tool Wash Method Always Will wash the syringe after each Workflow step. It also washes before and after syringe pickup from tool cassette. Typically used for Task that include syringe mixing, needle dipping and kinetically sensitive operations. After Pickup Wash of the syringe is limited to after pickup only. Typically used for Tasks where cross contamination is not an issue such as dispensing of the same reagent. Will also improve Workflow times. Never Tyically used for repeated Workflows where a syringe is used to aliquote the same and there is no chance of cross contanimation pre, during and post run. Wash Washing of barrel and needle to eliminate carry over from previous aliquote. Rinse Needle Rinses the outside of the needle only. Typically used when adding reagent or standard and the needle is dipped during dispense. Will eliminate carryover. Wash Tool Wash Volume (µL) See Default Table Syringe volume used for washing cycles. It is better to do a large number of small volume washes. Related to dilution factors. Tool Wash Aspiration Flowrate (µL/sec) See Default Table Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples Tool Wash Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Tool Wash Cycles See Default Table Number of wash cycles. Prime Type Prime Method Prime Settings Syringe wash is to remove carryover. Auto is a predefined syringe wash procedure for a Task. Parameters typically include wash on solution change, before and after syringe park in tool cassette. Auto Tool Wash Settings Wash Type Auto Auto Syringe prime is designed to remove airbubbles and ensure syringe is completely filled with the selected solution prior to aspiration. Auto is a predefined prime procedure for a Task and Syringe. It typically includes a prime step if the syringe has before all task aspirations if the syringe has not been prviously primed with the selected solution. Always Enables priming before every Task volume aspiration Never Removes priming process from the Task. To Tube Priming dispense to selected tube/vial To Waste Priming dispense to waste wash station Auto To Tube Prime Volume (µL) Syringe volume set for priming. It is better to do a large number of small volume washes. Related to dilution factors. Prime Aspiration Flowrate (µL/sec) Prime aspiration flowrate should be slow enough to ensure cavitation does not occur Prime Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution. A longer pause is required for larger syringe volumes and high viscosity liquids. Prime Dispense Flowrate (µL/sec) Prime dispense flowrate should be as fast as possible to assist air bubble removal Prime Dispense Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Tool Wash Cycles Number of times plunger is cycled for the wash process 5.3.2.1.4 Aliquot Sample Task Summary Adds Sample from a series of input tubes to a series of output tubes. Processing Function is specifically designed to aliquot a sample from a single input tube/vial to a single output tube/vial. Typical Use Adding sample from an input vial to output. Tool Settings and Options Setting Options Volume Increments (µL) Volume inciments (µL) 36 Default Selections Description Type increment volume Rense needles between dispenses (sec) zero Timed needle rinse between dispenses. Typically used if needle is dipped in solution on output vial dispense. Volume to over aspirate (%) zero Over aspiration function to counter system backlash. Draws the plunger past the selected volume by slected %, then dispenses the over aspiration amount back into input vial before dispensing the selected volume into the output vial. Aspirate Needle Position Bottom of the vial Position of the needle during aspiration measured as mm below the septum cap. Used if vial contains sedimant or requires access to supernatent layer. Dispense Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Pre Aspirate Air Gap (µL) zero Aspiration of an air gap over the liquid. Often used to dipense all liquid from the syringe and needle to minimise carryover or avoid prolonged contact with corrosive solvents. Aspirate Flowrate (µL/sec) See Default Table Aspiration flowrate can be varied to compensate for liquid viscosity or process requirements. Plunger drive has a finite velocity and force capability so flowrate range and accuracy is dependent on syringe volume. Aspirate Pause (sec) See Default Table Timed pause after plunger aspiration before dispensing. Pause should be increased with high aspirating plunger speeds or high viscosity liquids are used so liquid head can catch up with the plunger for full volume fill. Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Dispense Pause (sec) See Default Table Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. This results in greater accuracy and reproducibilty. A loner pause is required for larger syringe volumes Dispense Settings Tool Wash Method Will wash the syringe after each Workflow step. It also washes before and after syringe pickup from tool cassette. Typically used for Task that include syringe mixing, needle dipping and kinetically sensitive operations. After Pickup Wash of the syringe is limited to after pickup only. Typically used for Tasks where cross contamination is not an issue such as dispensing of the same reagent. Will also improve Workflow times. Never Tyically used for repeated Workflows where a syringe is used to aliquote the same and there is no chance of cross contanimation pre, during and post run. Wash Washing of barrel and needle to eliminate carry over from previous aliquote. Rinse Needle Rinses the outside of the needle only. Typically used when adding reagent or standard and the needle is dipped during dispense. Will eliminate carryover. Wash See Default Table Syringe volume used for washing cycles. It is better to do a large number of small volume washes. Related to dilution factors. Tool Wash Aspiration Flowrate (µL/sec) See Default Table Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples Tool Wash Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Tool Wash Cycles See Default Table Number of wash cycles. Prime Method 37 Always Tool Wash Volume (µL) Prime Type Prime Settings Syringe wash is to remove carryover. Auto is a predefined syringe wash procedure for a Task. Parameters typically include wash on solution change, before and after syringe park in tool cassette. Auto Tool Wash Settings Wash Type Auto Auto Syringe prime is designed to remove airbubbles and ensure syringe is completely filled with the selected solution prior to aspiration. Auto is a predefined prime procedure for a Task and Syringe. It typically includes a prime step if the syringe has before all task aspirations if the syringe has not been prviously primed with the selected solution. Always Enables priming before every Task volume aspiration Never Removes priming process from the Task. To Tube Priming dispense to selected tube/vial To Waste Priming dispense to waste wash station Auto To Tube Prime Volume (µL) Syringe volume set for priming. It is better to do a large number of small volume washes. Related to dilution factors. Prime Aspiration Flowrate (µL/sec) Prime aspiration flowrate should be slow enough to ensure cavitation does not occur Prime Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution. A longer pause is required for larger syringe volumes and high viscosity liquids. Prime Dispense Flowrate (µL/sec) Prime dispense flowrate should be as fast as possible to assist air bubble removal Prime Dispense Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Tool Wash Cycles Number of times plunger is cycled for the wash process Syringe Mix Enables mixing of the sample using the current syringe once the task volume hads been dispensed Syringe Mix Volume (µL) Syringe volume set for mxing cycles. It is better to do a large number of large volume washes. Syringe Mix Needle Position Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Below the septa Syringe Mix Aspirate Flowrate (µL/sec) Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples. Syringe Mix Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Syringe Mix Dispense Flowrate (µL/sec) Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Syringe Mix Settings Number of times plunger is cycled for the mixing process Syringe Mix Cycles 5.3.2.1.5 Aliquot Supernatant Task Summary Adds Supernatant Sample at a nominated depth from a series of input tubes to a series of output tubes. Processing Typical Use Enables needle depth to be selected for an input vial/tube to remove the supernatant to an output vial. Tool Settings and Options Setting Options Starting Dispense Volume (µL) Sarting Volume (µL) Type start volume Volume Increments (µL) Volume inciments (µL) Type increment volume Dispense Settings 38 Default Selections Description Rense needles between dispenses (sec) zero Timed needle rinse between dispenses. Typically used if needle is dipped in solution on output vial dispense. Volume to over aspirate (%) zero Over aspiration function to counter system backlash. Draws the plunger past the selected volume by slected %, then dispenses the over aspiration amount back into input vial before dispensing the selected volume into the output vial. Aspirate Needle Position Bottom of the vial Position of the needle during aspiration measured as mm below the septum cap. Used if vial contains sedimant or requires access to supernatent layer. Dispense Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Pre Aspirate Air Gap (µL) zero Aspiration of an air gap over the liquid. Often used to dipense all liquid from the syringe and needle to minimise carryover or avoid prolonged contact with corrosive solvents. Aspirate Flowrate (µL/sec) See Default Table Aspiration flowrate can be varied to compensate for liquid viscosity or process requirements. Plunger drive has a finite velocity and force capability so flowrate range and accuracy is dependent on syringe volume. Aspirate Pause (sec) See Default Table Timed pause after plunger aspiration before dispensing. Pause should be increased with high aspirating plunger speeds or high viscosity liquids are used so liquid head can catch up with the plunger for full volume fill. Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Dispense Pause (sec) Tool Wash Method Syringe wash is to remove carryover. Auto is a predefined syringe wash procedure for a Task. Parameters typically include wash on solution change, before and after syringe park in tool cassette. Always Will wash the syringe after each Workflow step. It also washes before and after syringe pickup from tool cassette. Typically used for Task that include syringe mixing, needle dipping and kinetically sensitive operations. After Pickup Wash of the syringe is limited to after pickup only. Typically used for Tasks where cross contamination is not an issue such as dispensing of the same reagent. Will also improve Workflow times. Never Tyically used for repeated Workflows where a syringe is used to aliquote the same and there is no chance of cross contanimation pre, during and post run. Wash Washing of barrel and needle to eliminate carry over from previous aliquote. Rinse Needle Rinses the outside of the needle only. Typically used when adding reagent or standard and the needle is dipped during dispense. Will eliminate carryover. Wash Tool Wash Volume (µL) See Default Table Syringe volume used for washing cycles. It is better to do a large number of small volume washes. Related to dilution factors. Tool Wash Aspiration Flowrate (µL/sec) See Default Table Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples Tool Wash Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Tool Wash Cycles See Default Table Number of wash cycles. Prime Type Prime Method Prime Settings Auto Auto Tool Wash Settings Wash Type Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. This results in greater accuracy and reproducibilty. A loner pause is required for larger syringe volumes See Default Table Auto Syringe prime is designed to remove airbubbles and ensure syringe is completely filled with the selected solution prior to aspiration. Auto is a predefined prime procedure for a Task and Syringe. It typically includes a prime step if the syringe has before all task aspirations if the syringe has not been prviously primed with the selected solution. Always Enables priming before every Task volume aspiration Never Removes priming process from the Task. To Tube Priming dispense to selected tube/vial To Waste Priming dispense to waste wash station Auto To Tube Prime Volume (µL) Syringe volume set for priming. It is better to do a large number of small volume washes. Related to dilution factors. Prime Aspiration Flowrate (µL/sec) Prime aspiration flowrate should be slow enough to ensure cavitation does not occur Prime Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution. A longer pause is required for larger syringe volumes and high viscosity liquids. Prime Dispense Flowrate (µL/sec) Prime dispense flowrate should be as fast as possible to assist air bubble removal Prime Dispense Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Tool Wash Cycles Number of times plunger is cycled for the wash process Syringe Mix Enables mixing of the sample using the current syringe once the task volume hads been dispensed Syringe Mix Volume (µL) Syringe volume set for mxing cycles. It is better to do a large number of large volume washes. Syringe Mix Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Syringe Mix Aspirate Flowrate (µL/sec) Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples. Syringe Mix Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Syringe Mix Dispense Flowrate (µL/sec) Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Syringe Mix Settings Syringe Mix Cycles 5.3.2.1.6 Add Internal Standard 39 Number of times plunger is cycled for the mixing process Task Summary Adds Internal Standard from an input tube(s) to a series of output tubes. Processing Typical Use Adding Internal Standard(s) in a Workflow Tool Settings and Options Setting Options Volume Increments (µL) Volume inciments (µL) Default Selections Description Type increment volume Rense needles between dispenses (sec) zero Timed needle rinse between dispenses. Typically used if needle is dipped in solution on output vial dispense. Volume to over aspirate (%) zero Over aspiration function to counter system backlash. Draws the plunger past the selected volume by slected %, then dispenses the over aspiration amount back into input vial before dispensing the selected volume into the output vial. Aspirate Needle Position Bottom of the vial Position of the needle during aspiration measured as mm below the septum cap. Used if vial contains sedimant or requires access to supernatent layer. Dispense Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Pre Aspirate Air Gap (µL) zero Aspiration of an air gap over the liquid. Often used to dipense all liquid from the syringe and needle to minimise carryover or avoid prolonged contact with corrosive solvents. Aspirate Flowrate (µL/sec) See Default Table Aspiration flowrate can be varied to compensate for liquid viscosity or process requirements. Plunger drive has a finite velocity and force capability so flowrate range and accuracy is dependent on syringe volume. Aspirate Pause (sec) See Default Table Timed pause after plunger aspiration before dispensing. Pause should be increased with high aspirating plunger speeds or high viscosity liquids are used so liquid head can catch up with the plunger for full volume fill. Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Dispense Pause (sec) See Default Table Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. This results in greater accuracy and reproducibilty. A loner pause is required for larger syringe volumes Dispense Settings Tool Wash Method Tool Wash Settings 40 Wash Type Auto Syringe wash is to remove carryover. Auto is a predefined syringe wash procedure for a Task. Parameters typically include wash on solution change, before and after syringe park in tool cassette. Always Will wash the syringe after each Workflow step. It also washes before and after syringe pickup from tool cassette. Typically used for Task that include syringe mixing, needle dipping and kinetically sensitive operations. After Pickup Wash of the syringe is limited to after pickup only. Typically used for Tasks where cross contamination is not an issue such as dispensing of the same reagent. Will also improve Workflow times. Never Tyically used for repeated Workflows where a syringe is used to aliquote the same and there is no chance of cross contanimation pre, during and post run. Wash Washing of barrel and needle to eliminate carry over from previous aliquote. Rinse Needle Rinses the outside of the needle only. Typically used when adding reagent or standard and the needle is dipped during dispense. Will eliminate carryover. Auto Wash Tool Wash Volume (µL) See Default Table Syringe volume used for washing cycles. It is better to do a large number of small volume washes. Related to dilution factors. Tool Wash Aspiration Flowrate (µL/sec) See Default Table Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples Tool Wash Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Tool Wash Cycles See Default Table Number of wash cycles. Prime Type Prime Method Prime Settings Auto Syringe prime is designed to remove airbubbles and ensure syringe is completely filled with the selected solution prior to aspiration. Auto is a predefined prime procedure for a Task and Syringe. It typically includes a prime step if the syringe has before all task aspirations if the syringe has not been prviously primed with the selected solution. Always Enables priming before every Task volume aspiration Never Removes priming process from the Task. To Tube Priming dispense to selected tube/vial To Waste Priming dispense to waste wash station Auto To Tube Prime Volume (µL) Syringe volume set for priming. It is better to do a large number of small volume washes. Related to dilution factors. Prime Aspiration Flowrate (µL/sec) Prime aspiration flowrate should be slow enough to ensure cavitation does not occur Prime Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution. A longer pause is required for larger syringe volumes and high viscosity liquids. Prime Dispense Flowrate (µL/sec) Prime dispense flowrate should be as fast as possible to assist air bubble removal Prime Dispense Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Tool Wash Cycles Number of times plunger is cycled for the wash process Syringe Mix Enables mixing of the sample using the current syringe once the task volume hads been dispensed Syringe Mix Volume (µL) Syringe volume set for mxing cycles. It is better to do a large number of large volume washes. Syringe Mix Needle Position Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Below the septa Syringe Mix Aspirate Flowrate (µL/sec) Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples. Syringe Mix Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Syringe Mix Dispense Flowrate (µL/sec) Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Syringe Mix Settings Number of times plunger is cycled for the mixing process Syringe Mix Cycles 5.3.2.1.7 Add Surrogate Task Summary Adds Surrogate Standard from an input tube(s) to a series of output tubes. Processing Typical Use Adding Surrogate Standard(s) in a Workflow Tool Settings and Options Setting Options Volume Increments (µL) Volume inciments (µL) 41 Default Selections Description Type increment volume Rense needles between dispenses (sec) zero Timed needle rinse between dispenses. Typically used if needle is dipped in solution on output vial dispense. Volume to over aspirate (%) zero Over aspiration function to counter system backlash. Draws the plunger past the selected volume by slected %, then dispenses the over aspiration amount back into input vial before dispensing the selected volume into the output vial. Aspirate Needle Position Bottom of the vial Position of the needle during aspiration measured as mm below the septum cap. Used if vial contains sedimant or requires access to supernatent layer. Dispense Settings Dispense Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Pre Aspirate Air Gap (µL) zero Aspiration of an air gap over the liquid. Often used to dipense all liquid from the syringe and needle to minimise carryover or avoid prolonged contact with corrosive solvents. Aspirate Flowrate (µL/sec) See Default Table Aspiration flowrate can be varied to compensate for liquid viscosity or process requirements. Plunger drive has a finite velocity and force capability so flowrate range and accuracy is dependent on syringe volume. Aspirate Pause (sec) See Default Table Timed pause after plunger aspiration before dispensing. Pause should be increased with high aspirating plunger speeds or high viscosity liquids are used so liquid head can catch up with the plunger for full volume fill. Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Dispense Pause (sec) See Default Table Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. This results in greater accuracy and reproducibilty. A loner pause is required for larger syringe volumes Tool Wash Method Will wash the syringe after each Workflow step. It also washes before and after syringe pickup from tool cassette. Typically used for Task that include syringe mixing, needle dipping and kinetically sensitive operations. After Pickup Wash of the syringe is limited to after pickup only. Typically used for Tasks where cross contamination is not an issue such as dispensing of the same reagent. Will also improve Workflow times. Never Tyically used for repeated Workflows where a syringe is used to aliquote the same and there is no chance of cross contanimation pre, during and post run. Wash Washing of barrel and needle to eliminate carry over from previous aliquote. Rinse Needle Rinses the outside of the needle only. Typically used when adding reagent or standard and the needle is dipped during dispense. Will eliminate carryover. Wash See Default Table Syringe volume used for washing cycles. It is better to do a large number of small volume washes. Related to dilution factors. Tool Wash Aspiration Flowrate (µL/sec) See Default Table Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples Tool Wash Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Tool Wash Cycles See Default Table Number of wash cycles. Prime Method 42 Always Tool Wash Volume (µL) Prime Type Prime Settings Syringe wash is to remove carryover. Auto is a predefined syringe wash procedure for a Task. Parameters typically include wash on solution change, before and after syringe park in tool cassette. Auto Tool Wash Settings Wash Type Auto Auto Syringe prime is designed to remove airbubbles and ensure syringe is completely filled with the selected solution prior to aspiration. Auto is a predefined prime procedure for a Task and Syringe. It typically includes a prime step if the syringe has before all task aspirations if the syringe has not been prviously primed with the selected solution. Always Enables priming before every Task volume aspiration Never Removes priming process from the Task. To Tube Priming dispense to selected tube/vial To Waste Priming dispense to waste wash station Auto To Tube Prime Volume (µL) Syringe volume set for priming. It is better to do a large number of small volume washes. Related to dilution factors. Prime Aspiration Flowrate (µL/sec) Prime aspiration flowrate should be slow enough to ensure cavitation does not occur Prime Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution. A longer pause is required for larger syringe volumes and high viscosity liquids. Prime Dispense Flowrate (µL/sec) Prime dispense flowrate should be as fast as possible to assist air bubble removal Prime Dispense Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Tool Wash Cycles Number of times plunger is cycled for the wash process Syringe Mix Enables mixing of the sample using the current syringe once the task volume hads been dispensed Syringe Mix Volume (µL) Syringe volume set for mxing cycles. It is better to do a large number of large volume washes. Syringe Mix Needle Position Syringe Mix Settings Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Below the septa Syringe Mix Aspirate Flowrate (µL/sec) Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples. Syringe Mix Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Syringe Mix Dispense Flowrate (µL/sec) Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Number of times plunger is cycled for the mixing process Syringe Mix Cycles 5.3.2.1.8 Add Diluent Task Summary Adds dilute solution from an input tube(s) to a series of output tubes. Also has a syringe mixing step. Processing Typical Use Dilution of output vial(s) using a single solvent Tool Settings and Options Setting Options Volume Increments (µL) Volume inciments (µL) Default Selections Description Type increment volume Rense needles between dispenses (sec) zero Timed needle rinse between dispenses. Typically used if needle is dipped in solution on output vial dispense. Volume to over aspirate (%) zero Over aspiration function to counter system backlash. Draws the plunger past the selected volume by slected %, then dispenses the over aspiration amount back into input vial before dispensing the selected volume into the output vial. Aspirate Needle Position Bottom of the vial Position of the needle during aspiration measured as mm below the septum cap. Used if vial contains sedimant or requires access to supernatent layer. Dispense Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Pre Aspirate Air Gap (µL) zero Aspiration of an air gap over the liquid. Often used to dipense all liquid from the syringe and needle to minimise carryover or avoid prolonged contact with corrosive solvents. Aspirate Flowrate (µL/sec) See Default Table Aspiration flowrate can be varied to compensate for liquid viscosity or process requirements. Plunger drive has a finite velocity and force capability so flowrate range and accuracy is dependent on syringe volume. Aspirate Pause (sec) See Default Table Timed pause after plunger aspiration before dispensing. Pause should be increased with high aspirating plunger speeds or high viscosity liquids are used so liquid head can catch up with the plunger for full volume fill. Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Dispense Pause (sec) See Default Table Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. This results in greater accuracy and reproducibilty. A loner pause is required for larger syringe volumes Dispense Settings Tool Wash Method 43 Auto Syringe wash is to remove carryover. Auto is a predefined syringe wash procedure for a Task. Parameters typically include wash on solution change, before and after syringe park in tool cassette. Always Will wash the syringe after each Workflow step. It also washes before and after syringe pickup from tool cassette. Typically used for Task that include syringe mixing, needle dipping and kinetically sensitive operations. After Pickup Wash of the syringe is limited to after pickup only. Typically used for Tasks where cross contamination is not an issue such as dispensing of the same reagent. Will also improve Workflow times. Auto Tool Wash Settings Wash Type Tyically used for repeated Workflows where a syringe is used to aliquote the same and there is no chance of cross contanimation pre, during and post run. Wash Washing of barrel and needle to eliminate carry over from previous aliquote. Rinse Needle Rinses the outside of the needle only. Typically used when adding reagent or standard and the needle is dipped during dispense. Will eliminate carryover. Wash Tool Wash Volume (µL) See Default Table Syringe volume used for washing cycles. It is better to do a large number of small volume washes. Related to dilution factors. Tool Wash Aspiration Flowrate (µL/sec) See Default Table Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples Tool Wash Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Tool Wash Cycles See Default Table Number of wash cycles. Prime Type Prime Method Prime Settings Never Auto Syringe prime is designed to remove airbubbles and ensure syringe is completely filled with the selected solution prior to aspiration. Auto is a predefined prime procedure for a Task and Syringe. It typically includes a prime step if the syringe has before all task aspirations if the syringe has not been prviously primed with the selected solution. Always Enables priming before every Task volume aspiration Never Removes priming process from the Task. To Tube Priming dispense to selected tube/vial To Waste Priming dispense to waste wash station Auto To Tube Prime Volume (µL) Syringe volume set for priming. It is better to do a large number of small volume washes. Related to dilution factors. Prime Aspiration Flowrate (µL/sec) Prime aspiration flowrate should be slow enough to ensure cavitation does not occur Prime Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution. A longer pause is required for larger syringe volumes and high viscosity liquids. Prime Dispense Flowrate (µL/sec) Prime dispense flowrate should be as fast as possible to assist air bubble removal Prime Dispense Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Tool Wash Cycles Number of times plunger is cycled for the wash process Syringe Mix Enables mixing of the sample using the current syringe once the task volume hads been dispensed Syringe Mix Volume (µL) Syringe volume set for mxing cycles. It is better to do a large number of large volume washes. Syringe Mix Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Syringe Mix Aspirate Flowrate (µL/sec) Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples. Syringe Mix Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Syringe Mix Dispense Flowrate (µL/sec) Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Syringe Mix Settings Syringe Mix Cycles 5.3.2.1.9 Add Reagent Task Summary Adds a reagent from an input tube(s) to a series of output tubes. Processing Typical Use Adding a single Reagent to output vial(s) 44 Number of times plunger is cycled for the mixing process Tool Settings and Options Setting Options Volume Increments (µL) Volume inciments (µL) Default Selections Description Type increment volume Rense needles between dispenses (sec) zero Timed needle rinse between dispenses. Typically used if needle is dipped in solution on output vial dispense. Volume to over aspirate (%) zero Over aspiration function to counter system backlash. Draws the plunger past the selected volume by slected %, then dispenses the over aspiration amount back into input vial before dispensing the selected volume into the output vial. Aspirate Needle Position Bottom of the vial Position of the needle during aspiration measured as mm below the septum cap. Used if vial contains sedimant or requires access to supernatent layer. Dispense Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Pre Aspirate Air Gap (µL) zero Aspiration of an air gap over the liquid. Often used to dipense all liquid from the syringe and needle to minimise carryover or avoid prolonged contact with corrosive solvents. Aspirate Flowrate (µL/sec) See Default Table Aspiration flowrate can be varied to compensate for liquid viscosity or process requirements. Plunger drive has a finite velocity and force capability so flowrate range and accuracy is dependent on syringe volume. Aspirate Pause (sec) See Default Table Timed pause after plunger aspiration before dispensing. Pause should be increased with high aspirating plunger speeds or high viscosity liquids are used so liquid head can catch up with the plunger for full volume fill. Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Dispense Pause (sec) See Default Table Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. This results in greater accuracy and reproducibilty. A loner pause is required for larger syringe volumes Dispense Settings Tool Wash Method Will wash the syringe after each Workflow step. It also washes before and after syringe pickup from tool cassette. Typically used for Task that include syringe mixing, needle dipping and kinetically sensitive operations. After Pickup Wash of the syringe is limited to after pickup only. Typically used for Tasks where cross contamination is not an issue such as dispensing of the same reagent. Will also improve Workflow times. Never Tyically used for repeated Workflows where a syringe is used to aliquote the same and there is no chance of cross contanimation pre, during and post run. Wash Washing of barrel and needle to eliminate carry over from previous aliquote. Rinse Needle Rinses the outside of the needle only. Typically used when adding reagent or standard and the needle is dipped during dispense. Will eliminate carryover. Wash See Default Table Syringe volume used for washing cycles. It is better to do a large number of small volume washes. Related to dilution factors. Tool Wash Aspiration Flowrate (µL/sec) See Default Table Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples Tool Wash Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Tool Wash Cycles See Default Table Number of wash cycles. Prime Method 45 Always Tool Wash Volume (µL) Prime Type Prime Settings Syringe wash is to remove carryover. Auto is a predefined syringe wash procedure for a Task. Parameters typically include wash on solution change, before and after syringe park in tool cassette. Auto Tool Wash Settings Wash Type Auto Auto Syringe prime is designed to remove airbubbles and ensure syringe is completely filled with the selected solution prior to aspiration. Auto is a predefined prime procedure for a Task and Syringe. It typically includes a prime step if the syringe has before all task aspirations if the syringe has not been prviously primed with the selected solution. Always Enables priming before every Task volume aspiration Never Removes priming process from the Task. To Tube Priming dispense to selected tube/vial To Waste Priming dispense to waste wash station Auto To Tube Prime Volume (µL) Syringe volume set for priming. It is better to do a large number of small volume washes. Related to dilution factors. Prime Aspiration Flowrate (µL/sec) Prime aspiration flowrate should be slow enough to ensure cavitation does not occur Prime Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution. A longer pause is required for larger syringe volumes and high viscosity liquids. Prime Dispense Flowrate (µL/sec) Prime dispense flowrate should be as fast as possible to assist air bubble removal Prime Dispense Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Tool Wash Cycles Number of times plunger is cycled for the wash process Syringe Mix Enables mixing of the sample using the current syringe once the task volume hads been dispensed Syringe Mix Volume (µL) Syringe volume set for mxing cycles. It is better to do a large number of large volume washes. Syringe Mix Needle Position Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Below the septa Syringe Mix Aspirate Flowrate (µL/sec) Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples. Syringe Mix Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Syringe Mix Dispense Flowrate (µL/sec) Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Syringe Mix Settings Number of times plunger is cycled for the mixing process Syringe Mix Cycles 5.3.2.1.10 Add Reagent & React Task Summary Adds a reagent from an input tube(s) to a series of output tubes and provides a counter for timing reaction time after reagent is added. The next task in the Workflow is not performed until the minimum reactionn time expires. Processing Typical Use Used for kinetically sensitive reactions on aliquoting of a single reagent. Tool Settings and Options Setting Options Volume Increments (µL) Volume inciments (µL) Dispense Settings 46 Default Selections Description Type increment volume Rense needles between dispenses (sec) zero Timed needle rinse between dispenses. Typically used if needle is dipped in solution on output vial dispense. Volume to over aspirate (%) zero Over aspiration function to counter system backlash. Draws the plunger past the selected volume by slected %, then dispenses the over aspiration amount back into input vial before dispensing the selected volume into the output vial. Aspirate Needle Position Bottom of the vial Position of the needle during aspiration measured as mm below the septum cap. Used if vial contains sedimant or requires access to supernatent layer. Dispense Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Pre Aspirate Air Gap (µL) zero Aspiration of an air gap over the liquid. Often used to dipense all liquid from the syringe and needle to minimise carryover or avoid prolonged contact with corrosive solvents. Aspirate Flowrate (µL/sec) See Default Table Aspiration flowrate can be varied to compensate for liquid viscosity or process requirements. Plunger drive has a finite velocity and force capability so flowrate range and accuracy is dependent on syringe volume. Aspirate Pause (sec) See Default Table Timed pause after plunger aspiration before dispensing. Pause should be increased with high aspirating plunger speeds or high viscosity liquids are used so liquid head can catch up with the plunger for full volume fill. Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Dispense Pause (sec) See Default Table Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. This results in greater accuracy and reproducibilty. A loner pause is required for larger syringe volumes Tool Wash Method Always Will wash the syringe after each Workflow step. It also washes before and after syringe pickup from tool cassette. Typically used for Task that include syringe mixing, needle dipping and kinetically sensitive operations. After Pickup Wash of the syringe is limited to after pickup only. Typically used for Tasks where cross contamination is not an issue such as dispensing of the same reagent. Will also improve Workflow times. Never Tyically used for repeated Workflows where a syringe is used to aliquote the same and there is no chance of cross contanimation pre, during and post run. Wash Washing of barrel and needle to eliminate carry over from previous aliquote. Rinse Needle Rinses the outside of the needle only. Typically used when adding reagent or standard and the needle is dipped during dispense. Will eliminate carryover. Wash Tool Wash Volume (µL) See Default Table Syringe volume used for washing cycles. It is better to do a large number of small volume washes. Related to dilution factors. Tool Wash Aspiration Flowrate (µL/sec) See Default Table Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples Tool Wash Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Tool Wash Cycles See Default Table Number of wash cycles. Prime Type Prime Method Prime Settings Syringe wash is to remove carryover. Auto is a predefined syringe wash procedure for a Task. Parameters typically include wash on solution change, before and after syringe park in tool cassette. Auto Tool Wash Settings Wash Type Auto Auto Syringe prime is designed to remove airbubbles and ensure syringe is completely filled with the selected solution prior to aspiration. Auto is a predefined prime procedure for a Task and Syringe. It typically includes a prime step if the syringe has before all task aspirations if the syringe has not been prviously primed with the selected solution. Always Enables priming before every Task volume aspiration Never Removes priming process from the Task. To Tube Priming dispense to selected tube/vial To Waste Priming dispense to waste wash station Auto To Tube Prime Volume (µL) Syringe volume set for priming. It is better to do a large number of small volume washes. Related to dilution factors. Prime Aspiration Flowrate (µL/sec) Prime aspiration flowrate should be slow enough to ensure cavitation does not occur Prime Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution. A longer pause is required for larger syringe volumes and high viscosity liquids. Prime Dispense Flowrate (µL/sec) Prime dispense flowrate should be as fast as possible to assist air bubble removal Prime Dispense Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Tool Wash Cycles Number of times plunger is cycled for the wash process Syringe Mix Enables mixing of the sample using the current syringe once the task volume hads been dispensed Syringe Mix Volume (µL) Syringe volume set for mxing cycles. It is better to do a large number of large volume washes. Syringe Mix Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Syringe Mix Aspirate Flowrate (µL/sec) Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples. Syringe Mix Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Syringe Mix Dispense Flowrate (µL/sec) Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Syringe Mix Settings Syringe Mix Cycles 47 Number of times plunger is cycled for the mixing process 5.2.2.1.11 Serial Dispense Task Summary Washes series of µSPEed cartridges from an input tube(s) to waste. Wash task can be used for Activation, Condition and Washing of cartridges. Processing Typical Use Used for activation, conditioning and washing µSPEed cartridges though the Workflow Tool Settings and Options Setting Options Default Selections Description Starting Dispense Volume (µL) Sarting Volume (µL) Type start volume Volume Increments (µL) Volume inciments (µL) Type increment volume Rense needles between dispenses (sec) zero Timed needle rinse between dispenses. Typically used if needle is dipped in solution on output vial dispense. Volume to over aspirate (%) zero Over aspiration function to counter system backlash. Draws the plunger past the selected volume by slected %, then dispenses the over aspiration amount back into input vial before dispensing the selected volume into the output vial. Aspirate Needle Position Bottom of the vial Position of the needle during aspiration measured as mm below the septum cap. Used if vial contains sedimant or requires access to supernatent layer. Dispense Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Pre Aspirate Air Gap (µL) zero Aspiration of an air gap over the liquid. Often used to dipense all liquid from the syringe and needle to minimise carryover or avoid prolonged contact with corrosive solvents. Aspirate Flowrate (µL/sec) See Default Table Aspiration flowrate can be varied to compensate for liquid viscosity or process requirements. Plunger drive has a finite velocity and force capability so flowrate range and accuracy is dependent on syringe volume. Aspirate Pause (sec) See Default Table Timed pause after plunger aspiration before dispensing. Pause should be increased with high aspirating plunger speeds or high viscosity liquids are used so liquid head can catch up with the plunger for full volume fill. Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Dispense Pause (sec) See Default Table Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. This results in greater accuracy and reproducibilty. A loner pause is required for larger syringe volumes Serial Dispense Settings Tool Wash Method Wash Type Syringe wash is to remove carryover. Auto is a predefined syringe wash procedure for a Task. Parameters typically include wash on solution change, before and after syringe park in tool cassette. Always Will wash the syringe after each Workflow step. It also washes before and after syringe pickup from tool cassette. Typically used for Task that include syringe mixing, needle dipping and kinetically sensitive operations. After Pickup Wash of the syringe is limited to after pickup only. Typically used for Tasks where cross contamination is not an issue such as dispensing of the same reagent. Will also improve Workflow times. Never Tyically used for repeated Workflows where a syringe is used to aliquote the same and there is no chance of cross contanimation pre, during and post run. Wash Washing of barrel and needle to eliminate carry over from previous aliquote. Rinse Needle Rinses the outside of the needle only. Typically used when adding reagent or standard and the needle is dipped during dispense. Will eliminate carryover. Auto Wash Tool Wash Settings 48 Auto Tool Wash Volume (µL) See Default Table Syringe volume used for washing cycles. It is better to do a large number of small volume washes. Related to dilution factors. Tool Wash Aspiration Flowrate (µL/sec) See Default Table Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples Tool Wash Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Tool Wash Cycles See Default Table Number of wash cycles. Prime Type Prime Method Prime Settings Auto Syringe prime is designed to remove airbubbles and ensure syringe is completely filled with the selected solution prior to aspiration. Auto is a predefined prime procedure for a Task and Syringe. It typically includes a prime step if the syringe has before all task aspirations if the syringe has not been prviously primed with the selected solution. Always Enables priming before every Task volume aspiration Never Removes priming process from the Task. To Tube Priming dispense to selected tube/vial To Waste Priming dispense to waste wash station Auto To Tube Prime Volume (µL) Syringe volume set for priming. It is better to do a large number of small volume washes. Related to dilution factors. Prime Aspiration Flowrate (µL/sec) Prime aspiration flowrate should be slow enough to ensure cavitation does not occur Prime Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution. A longer pause is required for larger syringe volumes and high viscosity liquids. Prime Dispense Flowrate (µL/sec) Prime dispense flowrate should be as fast as possible to assist air bubble removal Prime Dispense Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Tool Wash Cycles Number of times plunger is cycled for the wash process Syringe Mix Enables mixing of the sample using the current syringe once the task volume hads been dispensed Syringe Mix Volume (µL) Syringe volume set for mxing cycles. It is better to do a large number of large volume washes. Syringe Mix Needle Position Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Below the septa Syringe Mix Aspirate Flowrate (µL/sec) Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples. Syringe Mix Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Syringe Mix Dispense Flowrate (µL/sec) Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Syringe Mix Cycles Number of times plunger is cycled for the mixing process Syringe Mix Settings 5.3.2.1.12 Makeup to Volume Task Summary Used in conjuction with "Serial Dispense", it adds diluent from a tube(s) to make up to a set volume in the Serial Dispense output tubes. Must be used after the Serial Dispense step. Processing Typical Use The Make Up To Volume task is used to add a calculated volume to each selected tube to make up its volume to the set value. The 'Make up to Volume' task will be used to make up the volume in each tube to 1000uL. Tool Settings and Options Setting Options Makup Volume (µL) Volume inciments (µL) 49 Default Selections Description Type increment volume Rense needles between dispenses (sec) zero Timed needle rinse between dispenses. Typically used if needle is dipped in solution on output vial dispense. Volume to over aspirate (%) zero Over aspiration function to counter system backlash. Draws the plunger past the selected volume by slected %, then dispenses the over aspiration amount back into input vial before dispensing the selected volume into the output vial. Aspirate Needle Position Bottom of the vial Position of the needle during aspiration measured as mm below the septum cap. Used if vial contains sedimant or requires access to supernatent layer. Dispense Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Pre Aspirate Air Gap (µL) zero Aspiration of an air gap over the liquid. Often used to dipense all liquid from the syringe and needle to minimise carryover or avoid prolonged contact with corrosive solvents. Aspirate Flowrate (µL/sec) See Default Table Aspiration flowrate can be varied to compensate for liquid viscosity or process requirements. Plunger drive has a finite velocity and force capability so flowrate range and accuracy is dependent on syringe volume. Aspirate Pause (sec) See Default Table Timed pause after plunger aspiration before dispensing. Pause should be increased with high aspirating plunger speeds or high viscosity liquids are used so liquid head can catch up with the plunger for full volume fill. Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Dispense Pause (sec) See Default Table Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. This results in greater accuracy and reproducibilty. A loner pause is required for larger syringe volumes Dispense Settings Tool Wash Method Will wash the syringe after each Workflow step. It also washes before and after syringe pickup from tool cassette. Typically used for Task that include syringe mixing, needle dipping and kinetically sensitive operations. After Pickup Wash of the syringe is limited to after pickup only. Typically used for Tasks where cross contamination is not an issue such as dispensing of the same reagent. Will also improve Workflow times. Never Tyically used for repeated Workflows where a syringe is used to aliquote the same and there is no chance of cross contanimation pre, during and post run. Wash Washing of barrel and needle to eliminate carry over from previous aliquote. Rinse Needle Rinses the outside of the needle only. Typically used when adding reagent or standard and the needle is dipped during dispense. Will eliminate carryover. Wash See Default Table Syringe volume used for washing cycles. It is better to do a large number of small volume washes. Related to dilution factors. Tool Wash Aspiration Flowrate (µL/sec) See Default Table Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples Tool Wash Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Tool Wash Cycles See Default Table Number of wash cycles. Prime Method 50 Always Tool Wash Volume (µL) Prime Type Prime Settings Syringe wash is to remove carryover. Auto is a predefined syringe wash procedure for a Task. Parameters typically include wash on solution change, before and after syringe park in tool cassette. Auto Tool Wash Settings Wash Type Auto Auto Syringe prime is designed to remove airbubbles and ensure syringe is completely filled with the selected solution prior to aspiration. Auto is a predefined prime procedure for a Task and Syringe. It typically includes a prime step if the syringe has before all task aspirations if the syringe has not been prviously primed with the selected solution. Always Enables priming before every Task volume aspiration Never Removes priming process from the Task. To Tube Priming dispense to selected tube/vial To Waste Priming dispense to waste wash station Auto To Tube Prime Volume (µL) Syringe volume set for priming. It is better to do a large number of small volume washes. Related to dilution factors. Prime Aspiration Flowrate (µL/sec) Prime aspiration flowrate should be slow enough to ensure cavitation does not occur Prime Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution. A longer pause is required for larger syringe volumes and high viscosity liquids. Prime Dispense Flowrate (µL/sec) Prime dispense flowrate should be as fast as possible to assist air bubble removal Prime Dispense Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Tool Wash Cycles Number of times plunger is cycled for the wash process Syringe Mix Enables mixing of the sample using the current syringe once the task volume hads been dispensed Syringe Mix Volume (µL) Syringe volume set for mxing cycles. It is better to do a large number of large volume washes. Syringe Mix Needle Position Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Below the septa Syringe Mix Aspirate Flowrate (µL/sec) Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples. Syringe Mix Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Syringe Mix Dispense Flowrate (µL/sec) Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Syringe Mix Settings Number of times plunger is cycled for the mixing process Syringe Mix Cycles 5.3.2.1.13 Syringe Mix Task Summary Enables syringe mixing of series of tubes. Processing Typical Use Syringe mixing of a vial contents Tool Settings and Options Setting Options Mix Volume (µL) Volume (µL) Default Description Mix volume Rense needles between dispenses (sec) zero Timed needle rinse between dispenses. Typically used if needle is dipped in solution on output vial dispense. Volume to over aspirate (%) zero Over aspiration function to counter system backlash. Draws the plunger past the selected volume by slected %, then dispenses the over aspiration amount back into input vial before dispensing the selected volume into the output vial. Aspirate Needle Position Bottom of the vial Position of the needle during aspiration measured as mm below the septum cap. Used if vial contains sedimant or requires access to supernatent layer. Dispense Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Pre Aspirate Air Gap (µL) zero Aspiration of an air gap over the liquid. Often used to dipense all liquid from the syringe and needle to minimise carryover or avoid prolonged contact with corrosive solvents. Aspirate Flowrate (µL/sec) See Default Table Aspiration flowrate can be varied to compensate for liquid viscosity or process requirements. Plunger drive has a finite velocity and force capability so flowrate range and accuracy is dependent on syringe volume. Aspirate Pause (sec) See Default Table Timed pause after plunger aspiration before dispensing. Pause should be increased with high aspirating plunger speeds or high viscosity liquids are used so liquid head can catch up with the plunger for full volume fill. Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Dispense Pause (sec) See Default Table Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. This results in greater accuracy and reproducibilty. A loner pause is required for larger syringe volumes Dispense Settings 51 Selections Tool Wash Method Always Will wash the syringe after each Workflow step. It also washes before and after syringe pickup from tool cassette. Typically used for Task that include syringe mixing, needle dipping and kinetically sensitive operations. After Pickup Wash of the syringe is limited to after pickup only. Typically used for Tasks where cross contamination is not an issue such as dispensing of the same reagent. Will also improve Workflow times. Never Tyically used for repeated Workflows where a syringe is used to aliquote the same and there is no chance of cross contanimation pre, during and post run. Wash Washing of barrel and needle to eliminate carry over from previous aliquote. Rinse Needle Rinses the outside of the needle only. Typically used when adding reagent or standard and the needle is dipped during dispense. Will eliminate carryover. Wash Tool Wash Volume (µL) See Default Table Syringe volume used for washing cycles. It is better to do a large number of small volume washes. Related to dilution factors. Tool Wash Aspiration Flowrate (µL/sec) See Default Table Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples Tool Wash Dispense Flowrate (µL/sec) See Default Table Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Tool Wash Cycles See Default Table Number of wash cycles. Prime Type Prime Method Prime Settings Syringe wash is to remove carryover. Auto is a predefined syringe wash procedure for a Task. Parameters typically include wash on solution change, before and after syringe park in tool cassette. Auto Tool Wash Settings Wash Type Auto Auto Syringe prime is designed to remove airbubbles and ensure syringe is completely filled with the selected solution prior to aspiration. Auto is a predefined prime procedure for a Task and Syringe. It typically includes a prime step if the syringe has before all task aspirations if the syringe has not been prviously primed with the selected solution. Always Enables priming before every Task volume aspiration Never Removes priming process from the Task. To Tube Priming dispense to selected tube/vial To Waste Priming dispense to waste wash station Auto To Tube Prime Volume (µL) Syringe volume set for priming. It is better to do a large number of small volume washes. Related to dilution factors. Prime Aspiration Flowrate (µL/sec) Prime aspiration flowrate should be slow enough to ensure cavitation does not occur Prime Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution. A longer pause is required for larger syringe volumes and high viscosity liquids. Prime Dispense Flowrate (µL/sec) Prime dispense flowrate should be as fast as possible to assist air bubble removal Prime Dispense Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Tool Wash Cycles Number of times plunger is cycled for the wash process Syringe Mix Enables mixing of the sample using the current syringe once the task volume hads been dispensed Syringe Mix Volume (µL) Syringe volume set for mxing cycles. It is better to do a large number of large volume washes. Syringe Mix Needle Position Below the septa Position of the needle during dispensing measured as mm below the septum cap. Used if needle is to be dipped in output solution during dispensing for reduction of needle droplet effect. Syringe Mix Aspirate Flowrate (µL/sec) Flowrate for syringe be set so liquid does not cavitate during aspiration. Aspiration speed can be reduced for viscous samples. Syringe Mix Aspirate Pause (sec) Dispense pause can be used to enable relaxation of plunger and/or trapped air in the solution prior to the needle being withdrawn from the tube. A longer pause is required for larger syringe volumes Syringe Mix Dispense Flowrate (µL/sec) Dispense flowrate can be varied to compensate for liquid viscosity, chromatography, kinetics requirements or sample velocity from the needle. Plunger drive has a finite velocity and force so flowrate range and accuracy is dependent on syringe volume. Syringe Mix Settings Syringe Mix Cycles 5.3.3 Resources TBA 52 Number of times plunger is cycled for the mixing process 5.3.4 System TBA 53 6 Accessories and Options A range of devices are available for the ePrep to expand the system’s capabilities. Some items are supplied standard with the ePrep and others are optional. Check at www.eprep.com.au for the latest information on accessories that are available for the ePrep. The following is simply provide an overview of each accessory with more detailed instructional information supplied with the Accessory. 6.1 Bar Code Reader The Bar Code Reader option for the ePrep comprises a 2D barcode engine capable of reading 1D and 2D barcodes. The barcode labels can be attached to a range of vial sizes. The reader is mounted in the lower section of the P-Drive and is easily retrofitted to the ePrep by laboratory staff or service personnel. The Bar Code Reader can be used for identification and recording of vials used in a workflow and records the following information: Date, Analysis Number, Work Order, Sample Number, Sample Name, Origin, Batch Number and Expiry Date. The Bar Code reader option is supplied with a Vial Gripper which is treated in the ePrep control system in the same way as a syringe. The Gripper has an RFID tag attached and is loaded onto the Tool Rack on the ePrep in the same way as a syringe. When the “Read Bar Code” option is selected as a task in the Axis software a range of vials to be read can be selected and the Tool is selected as the “Gripper”. The Gripper is identified and connected via the Xchange coupling. It is then used to pick up each vial in the selected range and rotates it through XXX degrees to read the barcode. The 2D barcode engine supports all main stream 1D barcodes as well as PDF417, QRCode (QR1, QR2,Micro QR), Data Matrix and GS-1 Databar™(RSS) (RSS-Limited, RSS-14, RSS-14 Stacked and RSSExpand). 6.2 Vortex Shaker An Orbital Shaker is available for vial mixing. It can be simply added to a Workflow in any position on the smellto bas the . Functions of the Shaker include: Selectable 0.5, 1 or 2 mm orbital motion Low stirring speed to ultra-vigorous mixing and vortexing speeds for viscous liquids; 60 to 3570 RPM Ultra-precise home positioning every time Buzz mode for re-suspending stubborn sediment The Shaker is supplied with specially designed racks for 2mL, 5mL and 10mL vials Vials are moved to or from the Vortex Shaker using the optional Vial Gripper tool. 54 6.3 Reagent Manifold When larger reagent or solvent volumes are required for a workflow the Reagent Manifold may be used to deliver solvents and reagents from bulk bottles stationed alongside the ePrep. Up to 10 ports are available to supply multiple off deck solvent reservoirs The manifold is fitted with one-way valve system that allows a syringe to be filled and then its dispensed flow channeled to a waste collection bottle without moving the syringe. This capability provides : more efficient conditioning of SPE cartridges more efficient rinsing of syringes between sample processing steps. The unit is mounted in the Accessories area, located on the left side of the ePrep deck. The manifold is fitted with six standard needle ports and four µSPEed syringe ports. Spares are available. 6.4 Syringe-Detector Interface The eDirect™ allows interfacing of the ePrep robot and sample preparation process directly to an external detector such as a Mass Spectrometer, UV/Vis, fluorescence, IR or any chromatography detector or chromatography interface. The ePrep syringe system provides a precise flow to the detector at a high pressure if required with sample transferred directly from the needle through a small bore fused silica lined transfer tube to the detector with minimal band broadening. The eDirect accepts a standard ePrep syringe that has a standard 23 gauge needle that seals directly to a soft internal seal in the eDirect. The three obvious ways to utilize the eDirect interface are : Inject an ePrep prepared sample from a vial on the ePrep deck into a detector or even an LC system. This effectively is using the ePrep as a conventional autosampler. Elute an ePrep prepared sample from a µSPEed SPE column directly into a detector. Effectively this gives a chromatographic separation from the µSPEed cartridge into various types of detectors including a mass spectrometer. The ePrep can drive an isocratic separation of the ePrep 50mm X 2.1mm column directly into a detector via eDirect. This combines the sample preparation and LC column chromatography separation into one automated step. 55 6.5 Gripper The Gripper is supplied with the Vial Bar Code Reader option but is also available as a stand-alone unit to be used for methods requiring vials to be moved from one position to another. The common situations where there is required is for moving a vial to a Vortex Shaker or heater block. 6.6 uSPEed Cartridge Rack The µSPEed Cartridge Rack enables reliable operation of µSPEed cartridges on the EPREP deck. The rack self-aligns ensuring correct engagement of the ePrep syringe with a µSPEed cartridge held in the rack. Each rack contains 96 cartridge positions and is supplied with ePrep ADAPTER Plate and RFID identification tag. 56 7 Maintenance and Troubleshooting 7.1 Preventative Maintenance TBA 7.2 Moving ePrep TBA 7.3 Specific Maintenance 7.3.1 Charging the piercer Image Decription Unscrew the Calibration Probe/ Screw Hex Tool from its position beside the Wash Station Using the Screw Hex end of tool to undo the screw at the base of the ePrep Foor Remove the Bumper from the foot Using a spanner loosen the Retaining Nut holding the old Piercer Remove the old piercer from the Foot Refit the new Piercer taking care not to cross thread the Retaining Nut during tightening Use a spanner to loosely tight the Retaining Nut 57 Remove a Syringe from the Tool Holder and insert the needle through the top of the Foot and through the Piercer. Ensure the needle can smoothly pass though the piecer. Tighten the Retaining Nut. Do not overtighten. Replace the Bumper Recheck passing the Syringe Needle through the Foot and Piecer. 58 7.3.2 Syringe Needle Replacement Syringe Specifications Removable Needle: 5-120 °C Accuracy and Reproducibility: ±1 % of displaced volume. Syringe Use Always inspect the syringe before use. Avoid unnecessary movement of the plunger when the syringe is dry. Never force the plunger Syringe Cleaning Syringe cleaning agents will usually depend on the contaminating material. Methanol, methylene chloride, acetonitrile and acetone are commonly used solvents for cleaning. After the syringe has been cleaned, rinse the syringe with acetone, remove plunger and air dry. CH3 COCH3 Rinse with acetone Air dry to store. Do not immerse the entire syringe in solventasthismay damage the adhesive used to bond parts of the syringe. • Clean externally by wiping with a tissue. Avoid cycling the plunger when the syringe is dry Needle Care Check the needle for burrs prior to use. Use a fine emery board or carborundum to remove burrs. To unblock needles, Remove the needle from the syringe and gently push the stylet wire through the needle. Blockages can be removed by removing the plunger and fill the syringe with solvent using another syringe. Re-insert the plunger and gently push solvent through needle. Never force the plunger. Too much pressure may crack the syringe barrel. Remove plunger and fill syringe with solvent using another syringe Insert plunger and GENTLY push solvent through needle. Needle Replacement To replace needles unscrew front cover nut and spring, remove needle. Carefully insert replacement needle into the front of the syringe, slide spring and cover nut over the needle and screw nut onto the front screw of the syringe barrel. Syringe Storage To protect against breakage store the syringe in its original packaging or on a syringe rack. Always thoroughly clean the syringe before storage. Shipping DO NOT return any syringe to EPREP unless requested to do so by an authorized EPREP representative. DO NOT return any syringe that has been used with radioactive, infectious or hazardous materials. Any syringe being returned must be clearly marked with a Return Authorization Number, which is available from your EPREP representative. 59 7.3.3 Instrument Recalibration Unscrew the Calibration Probe/ Screw Hex Tool from its position beside the Wash Station Using the Screw Hex end of tool to undo the screw at the base of the ePrep Once the screw has been removed , turn the Calibration Probe/ Screw Hex Tool over and firmly screw it into the threaded hole the screw was removed from ensure that the foot bumper remains in position Check the Calibration Probe and Vial Adaptor Plates are installed correctly. Open the Calibrate Deck option on the ePrep Software through System>Service>Calibrate Deck Click on Initalise. ePrep will perform initialisation process Click on Calibrate Deck. ePrep will move the Calibration Probe on the P-Drive to allocated positions on the deck and tool rack to record instrument calibration data. When complete calibration dialogue will display "Calibration updated successfully". Calibration data is automatically written to the instrument EPROM to be used during operation. 7.3.4 Updating Software and Firmware In the interests of continual improvement, ePrep will be regularly making available free software upgrades. These upgrades will add additional capabilities to ePrep as well as rectifying identified bugs in the software. After ensuring the Computer Tablet has access to the internet click on Home – Service – Software Updates. (should use pictures of the keys here) The software will guide you through the updates available and how to download and install them. Checking for updates can etither be done through the computer tablet. 7.4 Troubleshooting and FAQs 60 Fault/Issue Issue Explaination and Action USB Comms won't connect or reconnect Issue typically occurs when Instrument Comms doesn't disconnect properly during power failure or unexpected disconnection of the Control Tablet. Steps to correct: 1) Press the software Comms Button. Comms button will display USB symbol if successful connection is made. 2) Disconnect the USB cable and reconnect the cable to the Tablet. Comms button will display USB symbol if successful connection is made. 3) Cycle the instrument power to reset Comms .Comms button will display USB symbol if successful connection is made. Tube Groups Disappear on Saving Tube Groups must be assigned to a task before saving. Tube group not assigned to a task will be deleted on saving. Undetected Tubes or Tube Groups ePrep uses both ultrasonic and touch detection for determining tube/vial placement. To ensure the correct detection of vials use only the caps and septa supplied with the vials. Ensure all vials, caps and septa in a single rack are the same height and vial/cap type. If the ePrep fails to detect a particular vial, ensure the rack dimensions are correct for the vial size being used and the vials are closely located in the centre of the rack position. The volume entered for an input volume is the total volume liquid place in the vial NOT the vial volume. Eprep automatically accounts for the useable volume (ie. allowing for needle depth etc) to determine if sufficient input liquid is available for a Workflow. Validation Over volume Error Input Vial ePrep calculates the expected volume required from all nominated input vials required to complete the Workflow. If the User selected volumes of the input vials is less than calculated required volume, a validation error will be signaled. To overcome this error; 1) increase the volume of liquid in the input vial 2) select more than one vial for the Group (if allowed for the task) or 3) add additional task steps with alternate vials. Validation Over volume Error Output Vial If the total volume to be dispensed in to single Output Tube exceeds the defined system volume of that tube (eg. Microtiter Plate), a validation error will be signaled. Steps to correct: 1) Ensure a volume is not set for the Output Tube. If a volume is set, ePrep will assume that the set volume already exists will add this to any dispensed volume in its calculation. 2) Reduce the total dispensed volume so it does not exceed the defined volume Syringe trapped Air Bubbles Trapped Air Bubbles can be caused by: 1) Empty Wash station reservoir 2) High viscosity liquids 3) Incorrect aspiration and dispensing speeds 4) Partially blocked needle (see also Blocked Needles) 5) Needle seal damaged 6) Leaking syringe plunger 7) Inrease the pause time at end of the aspirate cycle. Blocked Needle Blocked needles are typically caused by pieces if septa cored during vial piercing. ePrep syringes use needles optimised for minimal septa piercing force, minimum septa coring and minimum restriction of sample on aspiration. However hard brittle septa can result in coring causing the syringe needle to block. Steps to correct: 1) Use conventional soft septa on vials 2) Ensure the needle tip is not damaged. Burrs on the needle caused by the needle hitting a hard object can cause septum coring. Unexpected reduced recovery of some compounds If septa material is damaged or cored and particles of anlytes are displaced into a sample vial, this septa material can extract analytes from the solution, causing low recoveries. Ensure syringe needles, septa piercer are in good condition and the correct grade of a soft septa is used. Droplets can formed at the needle tip when dispensing small volumes at low flowrates. These droplets can lead to reproducibility errors and sometimes the appearance of liquid above the septum and on the ePrep piercer. Steps to correct: Droplets remain on the syringe 1) When possible, dispense small volumes into liquid already in the Output Vial ie. Add the diluent needle during dispense. to the vial first. 2) Dispense liquids as fast as possible 3) Pause after dispense to allow the droplet time to dislodge. Sensor hit error on adjoining rack 61 Some rack combinations may foul the ePrep forked foot if place adjacent to each other. Ensure high racks are never be placed immediately left of a low rack/vials. Software Lockup If the ePrep software locks up (ie. All keystrokes are no responsive) the following procedure should be used to close ePrep software: 1) Swipe the Tablet from the bottom right upwards 2) Select Task Manager form the Task Bar menu 3) Click on ePrep software from the Task List 4) Click End Task 5) Restart the ePrep Software Observation of Sample Carryover Carry over is typically caused by insufficient wash and/or priming of the syringe before the next sample. Steps to correct: 1) Increase the syringe wash after each sample. It is better to use additional small volume wash cycles than a single large volume wash cycle to minimise carryover. 2) Increase the number of prime cycles before sample aspiration. 3) Prime to waste to ensure carryover sample is not recycled into next sample vial. My vial rack is not listed Rack definitions must be predefined in ePrep's software for them to be suitable for use with the ePrep. The ePrep software uses the rack and Mat definition to determine X and Y coordinates of vials when setting up and running a Workflow. Contact Eprep if your rack definition is not listed. Needle length will not reach the bottom of the vial ePrep syringes use an 80mm long needle and µSPEed cartridges use 50mm long needles. The ePrep senses the height of the septa cap and for aspiration from a vial will automatically insert the needle as far as possible without colliding with the septa cap or bottom of the vial. Effective vial penetration for an 80mm needle is 56mm below the septa cap and 25mm for µSPEed cartridges. When the volume of the vial has been correctly defined, the ePrep software will automatically determine the volume available to be aspirated given the needle penetration into the vial. When selecting volumes to be aspirated from particular vials, be aware of the volume that cannot be reached below the maximum penetration of the needle into a vial. Workflow did not aliquot all samples correctly If a Workflow does not visually or chromatographically aliquot all samples correctly, the following possible causes should be checked: 1) Check for needle blockage 2) Check set input vial volumes are correct and allowance for needle depth penetration has been considered. 3) Ensure sufficient mixing of sample after aliquots ePrep stopped with syringe/tool still engaged. If the ePrep has stopped or been stopped for any reason with the syringe still connected: 1) Turn ePrep power off and rotate the foot away from the syringe needle 2) Turn the ePrep power on 2) Open the ePrep software and enter a Workflow Run. 3) With the syringe held tightly in one hand, press the Release Tool button at the bottom right of the run screen with the other hand to eject the tool. 4) Replace the syringe on the tool rack Sample Mixing Use syringe mixing or vortex mixing once sample aliquots are complete to ensure output vial is homogeneous before sampling, Duplicate and Triplicate samples Sample task is a one input vial to one output vial. To achieve duplicate and triplicate samples, duplicate the task series in a second task group. Syringe Washing Syringe washing is an often-overlooked parameter, and when optimised, can significantly lower carryover. You will need to experiment with your syringe washing and sample priming routines, however 3–5 sample primes (sometimes called pumps), and three washes from the flowing Wash Station before and after injection give reasonably good results. If the sample is particularly viscous, you may need to use a viscosity delay, to allow time for the viscous sample to rise up into the syringe and avoid variable volumes being injected. 62 8 Replacement Parts 8.1 ePrep Replacement Parts Part No. Description Service Level X-axis Complete Changeover High Y-Axis Complete Changeover High Z-Axis Complete Changeover High 63 P-Drive Complete Changeover High Wash Station Unit High Wash Station Tubing High 8.2 Replacement Syringes and Needles Needle Syringes Part No. Code Description 01-09006 10µL EPREP Syringe 10 µL|80mm|26g|Cone| Removable Needle EPREP Teflon Tip Syringe 01-09014 100µL EPREP Syringe 100 µL|80mm|26g|Cone| Removable Needle EPREP Teflon Tip Syringe 01-09020 1mL EPREP Syringe 1 mL|80mm|26g|Cone| Removable Needle EPREP Teflon Tip Syringe 01-09026 10mL EPREP Syringe 10 mL|80mm|26g|Cone| Removable Needle EPREP Teflon Tip Syringe Replacement Needles 01-09803 Replacement Needle for 10-25µL Syringe, 80mm/Cone (PKT 2) 01-09807 Replacement Needle for 25µL- 500µL Syringe, 80mm/Cone (PKT 2) 01-09811 Replacement Needle for 1mL Syringe, 80mm/Cone (PKT 2) 01-09815 Replacment Needle for 5-25mL Syringe, 80mm/Cone (PKT 2) Replacment Piercer µSPEed Syringes Part No Code Description 01-09080 100µL µSPEed EPREP Syringe 100uL| µSPEed| EPREP Endurance™ Syringe 01-09083 500µL µSPEed EPREP Syringe 500µL | µSPEed| EPREP Endurance™ Syringe 01-09087 2.5mL µSPEed EPREP Syringe 2.5mL | µSPEed| EPREP Endurance™ Syringe 64 9 Glossary of Terms Term Description µSPEed Cartridges µSPEed cartridges offer a unique opportunity to revolutionise micro SPE and micro fractionation. Using a one-way check valve, the sample is aspirated through the cartridge and dispensed on to the top of a sorbent bed. Accessories A range of devices are available for the ePrep to expand the system’s capabilities. Some items are supplied standard with the ePrep and others are optional. Check at www.eprep.com.au for the latest information on accessories that are available for the ePrep. Adaptor Plate (Mat) The task of defining vial positions accurately is made easy for the operator by using vial racks whose coordinates have been mapped by ePrep and are included in the parameters supplied by ePrep. It just needs to be ensured by the user that the correct vial rack has been used and it is being used with the correct Vial Rack Adapter plate for that specific vial rack. Batch (Task Group) Batch processing is where the same Task is preformed on all samples before proceeding onto the next sample. Batch processing is the fasted way to process a group of samples as it eliminates the tool change and washing steps between samples. Gripper The Gripper is supplied with the Vial Bar Code Reader option but is also available as a stand-alone unit to be used for methods requiring vials to be moved from one position to another. P-Drive The P-Drive is the heart of the ePrep system with an array of actuators, motors and sensors incorporated. The P-Drive incorporates a separate microprocessor for controlling and monitoring the various functions. Rack RFID Tag ePrep uses RFID Tag identification to check validity and location of tube/vial racks on the deck. RFID Tags are placed on the rack or a Adapter Plate post depending on the rack configuration. Senor Foot The sensor foot at the bottom of the P-Drive is a mechanical switch that precisely detects the P-Drive foot touching an external feature. Sequential Sequential or serial processing is when Tasks to complete a full workflow on a the first sample are finished before starting the same Tasks on the second sample. Sequential processing is normally slower that batch processing as it typically requires tool changing and syringe washing between Task. Task A set of predefined actions that make up a sample prepartion workflow. A Task typically contains a tool, tool parameters, rack and accessory definitions and allocation of input and output vial/tubes Tool Station 12 stations for syringes and other tools that can be coupled to the P-drive via the ePrep Xchange coupling system. Each station is designed to hold the syringe/tool in the correct position for engagement by the Xchange coupling system. Tools ePrep syringes and tools are fitted with Radio Frequency Identification (RFID) ta Validation (Workflow) Workflow validation examines different characteristics of a workflow to locate issues that might prevent the workflow from Running Vial/Tube A tube/vial is a glass or plastic vessel for storage and manipulation of liquids. The range of vials that can be used with ePrep is only restricted to fitting in a defined rack Wash Station The Wash Station is designed for washing syringe needles to prevent cross contamination and also as a means to empty syringes to waste. Workflow Process ways in which a sample is treated prior to its analysis XCHANGE® ePrep’s patented system for automated syringe and tool exchange. 65
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2017:06:29 13:28:54+10:00 Create Date : 2017:06:29 13:28:54+10:00 Creator : pdftk 2.01 - www.pdftk.com Producer : itext-paulo-155 (itextpdf.sf.net-lowagie.com) Page Count : 66EXIF Metadata provided by EXIF.tools