ecom instruments 300011GR05 RFID Reader User Manual

ecom instruments GmbH RFID Reader

Contents

user manual

  Datum // date 15.03.2013 Teile-Nr. // part no. 300011 Dokument-Nr. Revision // document no. revision 300011AL11E 04 Head Module Settings User Manual Seite/gesamt // page/total 1 / 8 Dokument erstellt // document created SAS387 15.03.2013 Dokument geprüft // document checked FIH091 ,09.04.2013 User Manual: Head Module Settings ● Ablageort: I:\300011\083_Software\05 Dokumente\300011AL11E04_user_manual_head_module_settings.docx ● template no.: 0730QV06A03 ● template created: HAO006 20.01.2011 ● template checked: BEA373 20.01.2011 ● location: ISO drive ● ecom instruments GmbH Inhaltsverzeichnis  1 Head Module Settings .................................................................................................................... 2 1.1 Introduction ................................................................................................................................ 2 1.2 Enable Module........................................................................................................................... 3 1.3 #L|F – TLB30 ............................................................................................................................. 3 1.4 #H – UNI13 ................................................................................................................................ 4 1.5 #Q – ARE8 ................................................................................................................................ 4 1.6 #T – LID ..................................................................................................................................... 5 1.7 S# - SE955 ................................................................................................................................ 5 1.8 Wedge Data ............................................................................................................................... 6 1.9 Good Read ................................................................................................................................ 6 1.10 Version Info ............................................................................................................................. 7 2 Trigger Button Settings ................................................................................................................. 8 2.1 Map the trigger event “OEM Trigger” on a button ..................................................................... 8
  Datum // date 15.03.2013 Teile-Nr. // part no. 300011 Dokument-Nr. Revision // document no. revision 300011AL11E 04 Head Module Settings User Manual Seite/gesamt // page/total 2 / 8 Dokument erstellt // document created SAS387 15.03.2013 Dokument geprüft // document checked FIH091 ,09.04.2013 User Manual: Head Module Settings ● Ablageort: I:\300011\083_Software\05 Dokumente\300011AL11E04_user_manual_head_module_settings.docx ● template no.: 0730QV06A03 ● template created: HAO006 20.01.2011 ● template checked: BEA373 20.01.2011 ● location: ISO drive ● ecom instruments GmbH 1 Head Module Settings 1.1 Introduction The Head Module Settings are there for controlling the head modules. They provide the following: enable or disable a head module (see 1.2 Enable Module) set settings for each head module (see 1.3 #L|F – TLB30, 1.4 #H – UNI13, 1.5 #Q – ARE8 1.6 #T – LID and 1.7 S# - SE955), set a preamble/postamble for the output data (see 1.8 Wedge Data), enable or disable the beep that should be ringing out or not after a good read (see 1.9 Good Read), display version of the service of the head modules which is installed on your device (see 1.10 Version Info). The Head Module Settings are located in the Intermec Settings. To open the Head Module Settings click on the windows icon on the main screen. Then click on Settings ->System->Intermec Settings (see Step1-3). Scroll down until “Head Module Settings” (see Step4) and click on it. The Head Module Settings will be opened. After you have made any settings in the Head Module Settings you can start reading with your head module by clicking the blue center button on the keyboard of your device.     Step1               Step2                 Step3              Step4
  Datum // date 15.03.2013 Teile-Nr. // part no. 300011 Dokument-Nr. Revision // document no. revision 300011AL11E 04 Head Module Settings User Manual Seite/gesamt // page/total 3 / 8 Dokument erstellt // document created SAS387 15.03.2013 Dokument geprüft // document checked FIH091 ,09.04.2013 User Manual: Head Module Settings ● Ablageort: I:\300011\083_Software\05 Dokumente\300011AL11E04_user_manual_head_module_settings.docx ● template no.: 0730QV06A03 ● template created: HAO006 20.01.2011 ● template checked: BEA373 20.01.2011 ● location: ISO drive ● ecom instruments GmbH 1.2 Enable Module There is a possibility in the Head Module Settings called “Enable Module” where you can enable or disable a head module. Open the Head Module Settings and choose “Enable Module” (see Pic1). In the next window (see Pic2) you can choose one of a USB device (for example the LF reader) or one of a UART device (for example the SE955 scanner). Click on the OK button to save your choice.    Pic1: Head Module Settings           Pic2: Enable Module      1.3 #L|F – TLB30 After you have enabled the LF reader through selecting it in the “Enable Module” section in the Head Module Settings (see 1.2 Enable Module) you are now able to change some settings for the LF reader. Open the Head Module Settings and choose “Setting #L|F – TLB30” (see Pic3). In the next window (see Pic4) you can make any changes you want to do for the LF reader. Click on the OK button to save your changes.     Pic3: Head Module Settings after              enabling the LF reader           Pic4: LF reader settings
  Datum // date 15.03.2013 Teile-Nr. // part no. 300011 Dokument-Nr. Revision // document no. revision 300011AL11E 04 Head Module Settings User Manual Seite/gesamt // page/total 4 / 8 Dokument erstellt // document created SAS387 15.03.2013 Dokument geprüft // document checked FIH091 ,09.04.2013 User Manual: Head Module Settings ● Ablageort: I:\300011\083_Software\05 Dokumente\300011AL11E04_user_manual_head_module_settings.docx ● template no.: 0730QV06A03 ● template created: HAO006 20.01.2011 ● template checked: BEA373 20.01.2011 ● location: ISO drive ● ecom instruments GmbH 1.4 #H – UNI13 To make some changes for the HF reader, enable the reader in the “Enable Module” section in the Head Module Settings. Then click on “Setting #H – UNI13” (see Pic5). In the next window (see Pic6) make your changes you want to do for the HF reader and save them by clicking the OK button.     Pic5: Head Module Settings after              enabling the HF reader           Pic6: HF reader settings      1.5 #Q – ARE8 To make some changes for the ARE Trovan reader, enable the reader in the “Enable Module” section in the Head Module Settings. Then click on “Setting #Q – ARE8” (see Pic7). In the next window (see Pic8) make your changes you want to do for the ARE Trovan reader and save them by clicking the OK button.     Pic7: Head Module Settings after              enabling the ARE Trovan reader      Pic8: ARE Trovan reader settings
  Datum // date 15.03.2013 Teile-Nr. // part no. 300011 Dokument-Nr. Revision // document no. revision 300011AL11E 04 Head Module Settings User Manual Seite/gesamt // page/total 5 / 8 Dokument erstellt // document created SAS387 15.03.2013 Dokument geprüft // document checked FIH091 ,09.04.2013 User Manual: Head Module Settings ● Ablageort: I:\300011\083_Software\05 Dokumente\300011AL11E04_user_manual_head_module_settings.docx ● template no.: 0730QV06A03 ● template created: HAO006 20.01.2011 ● template checked: BEA373 20.01.2011 ● location: ISO drive ● ecom instruments GmbH 1.6 #T – LID To make some changes for the LID Trovan reader, enable the reader in the „Enable Module“ section in the Head Module Settings. Then click on “Setting #T - LID“ (see Pic9). In the next window (see Pic10) make your changes you want to do for the LID Trovan reader and save them by clicking the OK button.    Pic9: Head Module Settings after               enabling the LID Trovan reader      Pic10: LID Trovan reader settings      1.7 S# - SE955 To make some changes for the SE955 scanner, enable the scanner in the “Enable Module” section in the Head Module Settings. Then click on “Setting S# – SE955” (see Pic11). In the next window (see Pic12) make your changes you want to do for the SE955 scanner and save them by clicking the OK button.     Pic11: Head Module Settings after             enabling the SE955 scanner      Pic12: SE955 scanner settings
  Datum // date 15.03.2013 Teile-Nr. // part no. 300011 Dokument-Nr. Revision // document no. revision 300011AL11E 04 Head Module Settings User Manual Seite/gesamt // page/total 6 / 8 Dokument erstellt // document created SAS387 15.03.2013 Dokument geprüft // document checked FIH091 ,09.04.2013 User Manual: Head Module Settings ● Ablageort: I:\300011\083_Software\05 Dokumente\300011AL11E04_user_manual_head_module_settings.docx ● template no.: 0730QV06A03 ● template created: HAO006 20.01.2011 ● template checked: BEA373 20.01.2011 ● location: ISO drive ● ecom instruments GmbH 1.8 Wedge Data To set a preamble or postamble for the data which is read from a head module, open the Head Module Settings and click on “Wedge Data” (see Pic13). In the next window (see Pic14) set a preamble or postamble by filling out the corresponding text field and save your settings by clicking the OK button.  Note: You can also set an escape literal for preamble or postamble. The following escape literals are allowed: \a, \b, \t, \n, \v, \f, \r. A second special feature for preamble/postamble is to set one of the following codes:   #TAB (sends a tab)  #SPACE (sends a space)   #ENTER (sends an enter)  #xxx (xxx stands for a decimal number between 000 and 127; you can set any ASCII character for preamble/postamble by using the decimal code of the character -> for example if you set #013 as preamble or postamble a carriage return will be sent)    Pic13: Head Module Settings           Pic14: Preamble/Postamble       1.9 Good Read The Head Module Settings provide an option to set a beep for ringing out after a good read. To set this, open the Head Module Settings and click on “Good Read” (see Pic15). In the next window (see Pic16) you have the opportunity to set “no beep”, “one beep” or “two beeps”. Save your setting by clicking the OK button.    Pic15: Head Module Settings          Pic16: Beep options
  Datum // date 15.03.2013 Teile-Nr. // part no. 300011 Dokument-Nr. Revision // document no. revision 300011AL11E 04 Head Module Settings User Manual Seite/gesamt // page/total 7 / 8 Dokument erstellt // document created SAS387 15.03.2013 Dokument geprüft // document checked FIH091 ,09.04.2013 User Manual: Head Module Settings ● Ablageort: I:\300011\083_Software\05 Dokumente\300011AL11E04_user_manual_head_module_settings.docx ● template no.: 0730QV06A03 ● template created: HAO006 20.01.2011 ● template checked: BEA373 20.01.2011 ● location: ISO drive ● ecom instruments GmbH 1.10 Version Info Last point in the Head Module Settings gives you the opportunity to get information about the version of the service of the head modules which is installed on your device. Open the Head Module Settings and click on “Version Info” (see Pic17). In the next window you can see the version of the service (see Pic18).        Pic17: Head Module Settings        Pic18: Service Version
  Datum // date 15.03.2013 Teile-Nr. // part no. 300011 Dokument-Nr. Revision // document no. revision 300011AL11E 04 Head Module Settings User Manual Seite/gesamt // page/total 8 / 8 Dokument erstellt // document created SAS387 15.03.2013 Dokument geprüft // document checked FIH091 ,09.04.2013 User Manual: Head Module Settings ● Ablageort: I:\300011\083_Software\05 Dokumente\300011AL11E04_user_manual_head_module_settings.docx ● template no.: 0730QV06A03 ● template created: HAO006 20.01.2011 ● template checked: BEA373 20.01.2011 ● location: ISO drive ● ecom instruments GmbH 2 Trigger Button Settings 2.1 Map the trigger event “OEM Trigger” on a button  This is necessary to start reading with a head module. There is an event named “OEM Trigger” which is used in the service of the head modules to start reading with a head module. This event is mapped on the center scan button by default. You have five opportunities to map this event on a button:  on the center scan button, on the left side upper button, on the left side lower button, on the right side upper button and on the right side lower button.  To map a button on the event open the Intermec Settings. Therefore you have to click on the windows icon on the main screen.  In the next step you have to click on Settings -> System -> Intermec Settings.  To map the event on a button click on Device Settings -> Keypad -> Button Remapping (see Pic19-Pic21) in the Intermec Settings. In the next window you can map the “OEM Trigger” event on a button which you want to use to start reading with a head module (see Pic22).        Pic19: Intermec Settings        Pic20: Device Settings                    Pic22: Button Remapping  (“OEM Trigger” is mapped on the  Pic21: Keypad                   center scan button by default)

Navigation menu