ifm electronic DTS125-AA RFID Reader User Manual DTA101

ifm electronic gmbh RFID Reader DTA101

Contents

User Manual DTA101

Download: ifm electronic DTS125-AA RFID Reader User Manual DTA101
Mirror Download [FCC.gov]ifm electronic DTS125-AA RFID Reader User Manual DTA101
Document ID745728
Application IDv0m6ZgjgXx1Nei7ssO2pDQ==
Document DescriptionUser Manual DTA101
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize37.92kB (474055 bits)
Date Submitted2007-01-10 00:00:00
Date Available2007-01-10 00:00:00
Creation Date2006-10-05 14:22:42
Producing SoftwareAcrobat Distiller 4.05 for Windows
Document Lastmod2006-10-05 14:23:46
Document TitleUser Manual DTA101

Betriebsanleitung
Operating instructions
Notice d'utilisation
Lesekopf für
RF-Identifikationssysteme
Read head for
RF identification systems
ENGLISH
FRANÇAIS
Sachnr. 704026 / 01
10 / 2006
DTA101
DEUTSCH
Tête de lecture
pour identification par
radiofréquence (RFID)
RF-IDENTIFIKATIONSSYSTEM
DTA101
Diese Betriebsanleitung
... gilt für alle Geräte des Typs DTA101.
... richtet sich an fachkundige Personen im Sinne von EMV- und der Niederspannungs-Richtlinie.
... ist Bestandteil des Gerätes. Sie enthält Angaben zum korrekten Umgang mit
dem Produkt. Lesen Sie sie vor dem Einsatz, damit Sie mit Einsatzbedingungen, Installation und Betrieb vertraut werden. Befolgen Sie die Sicherheitshinweise.
Inhalt
1. Sicherheitsweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Seite 3
2. Bestimmungsgemäße Verwendung . . . . . . . . . . . . . . . . . . . . . . . . . . Seite 4
3. Funktionsweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Seite 4
4. Anzeigeelemente . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Seite 5
5. Montage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Seite 5
6. Elektrischer Anschluss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Seite 6
7. Der Lesekopf im AS-i Netzwerk
Grundeinstellung . . . . . . . . . . . . . . . . . . . . . .
Adressierung . . . . . . . . . . . . . . . . . . . . . . . . .
Analogwert-Repräsentation . . . . . . . . . . . . . . .
Belegung der Datenbits . . . . . . . . . . . . . . . . . .
Codewert-Darstellung durch Datenbit D16...D1
. . . . . . . . Seite
. . . . . . . . Seite
. . . . . . . . Seite
. . . . . . . . Seite
. . . . . . . . Seite
8. Funkanlagenzulassung. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Seite 8
9. EG-Konformitätserklärung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Seite 8
10. Wartung, Instandsetzung, Entsorgung . . . . . . . . . . . . . . . . . . . . . . . . Seite 8
11. Technische Daten
Maße . . . . . . . . . . . . . . . .
Vorbeifahrgeschwindigkeit.
Abstand zum ID-TAG . . . .
Abstand Leseköpfe . . . . . .
Seite
Seite
Seite
Seite
RF-IDENTIFIKATIONSSYSTEM
DTA101
1. Sicherheitshinweise
Allgemeines
Befolgen Sie die Angaben der Betriebsanleitung. Nichtbeachten der Hinweise, Verwendung außerhalb der nachstehend genannten bestimmungsgemäßen Verwendung, falsche Installation oder Handhabung können Beeinträchtigungen der Sicherheit von Menschen und Anlagen zur Folge haben.
Der Einbau und Anschluss muss den gültigen nationalen und internationalen Normen entsprechen. Die Verantwortung trägt derjenige, der das Gerät installiert.
Das Gerät darf nur von einer Elektrofachkraft eingebaut, angeschlossen und in Betrieb gesetzt werden, da die sichere Funktion des Gerätes und der Anlage nur bei
ordnungsgemäßer Installation gewährleistet ist.
Schalten Sie das Gerät extern spannungsfrei bevor Sie irgendwelche Arbeiten an
ihm vornehmen.
Das Gerät muss gemäß den Kriterien für sichere Kleinspannung (SELV) mit einer
externen Gleichspannung von 26,5...31,6 V versorgt werden.
Das Gerät ist gemäß nachstehender technischer Spezifikation in einem weiten Umgebungstemperaturbereich betreibbar. Aufgrund der zusätzlichen Eigenerwärmung
kann es an den Gehäusewandungen beim Berühren in heißer Umgebung zu hohen wahrnehmbaren Temperaturen kommen.
Bei Fehlfunktion des Gerätes oder bei Unklarheiten setzen Sie sich bitte mit dem
Hersteller in Verbindung. Eingriffe in das Gerät können schwerwiegende Beeinträchtigungen der Sicherheit von Menschen und Anlagen zur Folge haben. Sie sind
nicht zulässig und führen zu Haftungs- und Gewährleistungsauschluss.
Transportieren und lagern Sie keine entflammbaren Gase, Flüssigkeiten
oder explosive Stoffe im Bereich des Gerätes. Funkgeräte dürfen generell
nicht in der Nähe von Tankstellen, Kraftstoffdepots, Chemiewerken oder Sprengarbeiten benutzt werden.
Elektronische Geräte
Der Betrieb kann die Funktionsfähigkeit von nicht ordnungsgemäß geschirmten elektronischen Geräten beeinträchtigen. Schalten Sie das
Gerät in der Nähe medizinischer Geräte aus. Bitte informieren Sie sich bei Störungen ggf. beim Hersteller des jeweiligen Gerätes.
FCC Zulassungshinweis
Entsprechende Hinweise für die Funkzulassung USA/Kanada befinden sich im englischsprachigen Teil unter "1. Safety Instruction".
DEUTSCH
Funkanlagen
RF-IDENTIFIKATIONSSYSTEM
DTA101
2. Bestimmungsgemäße Verwendung
• Der Lesekopf DTA101 liest berührungslos Daten von systemkonformen
RFID-Transpondern (ID-TAGs),
• wandelt sie in digital codierte Werte
• und stellt diese der AS-i Steuerungsebene zur Verfügung
(AS-i Master, Controller oder Host).
Einsatzbereiche sind z.B.:
• Materialflusssteuerung und -kontrolle in Fertigungslinien,
• Lagermanagement durch automatische Lagerguterkennung,
• Behältermanagement, Kommissionierung oder die Warenverfolgung.
3. Funktionsweise
Die ID-TAGs werden passiv betrieben, d.h. ohne Batterie. Die zum Betrieb notwendige Energie wird vom Lesekopf aufgebracht.
Das physikalische Prinzip der Energieübertragung beruht auf der induktiven Kopplung. Die integrierte Antennenspule des Lesekopfes erzeugt ein magnetisches Feld,
das zu einem Teil die Antennenspule des ID-TAGs durchdringt.
Durch Induktion wird dort eine Spannung erzeugt die den Datenträger mit Energie
versorgt.
Lesekopf DTA101
Anzeige
Impuls
Antenne
HF- und
Analogschaltung
ID-TAG
Energie
Daten
µController
und
AS-interface
AS-i Master,
Controller oder Host
Prinzipielle Wirkungsweise
RF-IDENTIFIKATIONSSYSTEM
DTA101
4. Anzeigeelemente
grün
gelb
rot
LED
Zustand
Bedeutung
grün
EIN
Betriebsspannung ok
gelb
EIN
TAG gelesen
rot
EIN
Fehler AS-i Datenkommunikation
Betriebs- und Fehleranzeige am Lesekopf
5. Montage
Die Befestigung erfolgt wahlweise mit 2 Stk. M 4 Schrauben und Muttern oder
mittels Klemmhalterung. Informationen zum erhältlichen Montagezubehör finden
Sie im Internet unter:
➔ Datenblatt-Suche ➔ DTA101 ➔ Zubehör
DEUTSCH
www.ifm-electronic.com
Beispiel
Art.-Nr. E20898
Beispiel
Art.-Nr. E20901
Montagebeispiele
Bei der Montage von mehreren Leseköpfen die Mindestabstände zwischen den Systemen beachten ➔ siehe 11. Technische Daten.
RF-IDENTIFIKATIONSSYSTEM
DTA101
6. Elektrischer Anschluss
Den Lesekopf über die M12-Steckverbindung mit dem AS-i-Netz verbinden. Die
Spannungsversorgung erfolgt aus dem AS-i-Netz.
Eine Auswahl an Kabeldosen finden Sie im Internet unter:
www.ifm-electronic.com ➔ Datenblatt-Suche ➔ DTA101 ➔ Zubehör
1 BN
ASI+
3 BU
Adernfarben bei ifm-Kabeldosen:
1 = BN (braun)
3 = BU (blau)
ASI
Anschlussbelegung
Abstand AS-i Leitung zum Lesekopfgehäuse beachten.
A = 100 mm
Freiraum Lesekopf ↔ Leitung
RF-IDENTIFIKATIONSSYSTEM
DTA101
7. Der Lesekopf im ASi-Netzwerk
Grundeinstellung
Parameter
Wert
I/O Code [hex]
ID Code [hex]
Extended ID2 Code [hex]
ID1 Code für Codewert [hex]
Slave-Adresse (Werkseinstellung)
Adressierung
Der Lesekopf wird adressiert mit einem Adressiergerät (z.B. AC1144), dem Master
oder mit der AS-i-Software des Hosts (die Komponenten müssen AS-i Version 2.1
unterstützen).
Vergeben Sie eine Adresse zwischen 1 und 31.
Analogwert-Repräsentation
Für das AS-Interface ist der Lesekopf ein Analogeingang-Slave mit Übertragungsprotokoll nach Profil 7.3. Arbeitet der Master gemäß Master-Profil M3 oder M4,
erkennt er den Lesekopf automatisch und unterstützt das Profil 7.3.
Belegung der Datenbits
In einem Übertragungszyklus werden folgende Daten in Datentripel übertragen:
E2
E1 D16 D15 D14 D13 D12 D11 D10 D9
Extention
Bits
(statisch 0)
D8
D7
D6
D5
D4
D3
D2
D1
User Data Bits
DEUTSCH
E3
Additional Information Bits:
O = Overflow-Bit (wird bei den Werten 7FFF und 8000 Hex. gesetzt, sonst 0)
V = Valid-Bit (wird bei einem gültigen Wert gesetzt)
Codewert-Darstellung durch Datenbits D16...D1
Die Darstellung des ID-Wertes erfolgt als vorzeichenbehaftete 16 Bit Zahl.
Bereich
Dezimal
von
bis
Hex
von
bis
Wertebereich
32767
7FFF
Meldebereich
-1
-32768
FFFF
8000
Wert 0 = kein ID-TAG im Lesebereich oder ID-TAG nicht erkannt.
RF-IDENTIFIKATIONSSYSTEM
DTA101
8. Funkanlagenzulassung
Kennzeichnung nach R & TTE (Radio Equipment and Telecommunications Terminal
Equipment)
CE-Identifikationsnummer: CE 0682
Intended use: Verwendung in allen EU Staaten
9. EG-Konformitätserklärung
Die EG-Konformitätserklärung ist im Internet einsehbar unter:
www.ifm-electronic.com
➔ Datenblatt-Suche ➔ DTA101 ➔ weitere Informationen
10. Wartung, Instandsetzung, Entsorgung
Bei sachgemäßem Betrieb sind keine Maßnahmen für Wartung und Instandhaltung
notwendig. Das Gerät darf nur vom Hersteller repariert werden.
Entsorgen Sie das Gerät nach Gebrauch umweltgerecht gemäß den gültigen
nationalen Bestimmungen.
RF-IDENTIFIKATIONSSYSTEM
DTA101
11. Technische Daten
DTA101
Lesekopf DTS/125/RO/AS/US
mit integriertem AS-i Slave
Profil 7.3
schwenkbare M12-Steckverbindung
1: integrierte Antenne, 2: TAG-Positioniermarke (Antennenmitte)
Einsatzbereich
Erkennen von Objekten auf Transporteinrichtungen;
geeignet für Vorbeifahrgeschwindigkeiten bis 0,5 m/s
AS-i
Betriebsspannung
Stromaufnahme
Arbeitsfrequenz
Vorbeifahrgeschwindigkeit *
[V]
[mA]
[kHz]
[m/s]
26,5...31,6 DC (AS-i)
” 50
125
” 0.5
Abstand zum ID-TAG *
[mm]
” 15 (bei 0,5 m/s); ” 20 (statisch)
Abstand Lese-/Lesekopf
[mm]
Abstand Lese-/Schreibkopf** [mm]
Datenbereitstellungszeit
[ms]
Wertebereich
Umgebungsbedingungen
Schutzart, Schutzklasse
AS-i-Profil
E/A-Konfiguration
ID-Code
AS-i-Zertifikat
EMV
Gehäusewerkstoffe
Anzeige
• 200 (bei 0,5 m/s)
• 400 (bei 0,5 m/s)
” 70
DEUTSCH
Elektrische Ausführung
16 Bit (15 Bit ID-Wert, 1 Bit Meldungen)
Umgebungstemperatur: -20...50 °C
Lagertemperatur: -25....80 °C
Vibration: 20 g; 10...2000 Hz
Schock: 50 g; 11 ms
[Hex]
[Hex]
Anschluss
Bemerkungen
ifm electronic gmbh • Teichstraße 4 • D-45127 Essen
IP 67, III
7.3
71502
EN 50295 (1999-03)
PA (Polyamid)
3 LED
grün: Betriebsspannung
gelb: TAG gelesen
rot: Fehler AS-i Datenkommunikation
M12-Steckverbindung
*) bezogen auf ID-TAG E80301 (Mitte Schraube)
Abstände zu anderen ID-TAGs siehe jeweiliges Datenblatt (E803xx)
**) bezogen auf Lese-/Schreibkopf DTA100
Technische bnderungen behalten wir uns ohne Ankündigung vor !
DE - DTA101
17.03.2006
READ HEAD FOR RF IDENTICFICATION SYSTEMS
DTA101
The operating instructions
... apply to all DTA101 type units.
... are for authorised persons according to the EMC and low voltage directives.
... are part of the unit. They contain information about the correct handling of the
product. Read them before use to familiarise yourself with operating conditions,
installation and operation. Follow the safety instructions.
Contents
1. Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
2. Function and features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12
3. Operating principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12
4. Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
5. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
6. Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 14
7. The read head in the AS-i network
Basic setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Analogue value representation. . . . . . . . . . . . . . . . . . . .
Assignment of the data bits . . . . . . . . . . . . . . . . . . . . . .
Coded value representation using the data bits D16...D1.
. . . page
. . . page
. . . page
. . . page
. . . page
15
15
15
15
15
8. Approval of radio equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16
9. EC declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16
10. Maintenance, repair, disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16
11. Technical data
Dimension . . . . . . . . . . . . . . . .
Travel speed . . . . . . . . . . . . . . .
Distance to the ID tag . . . . . . . .
Separation between read heads .
10
page
page
page
page
17
17
17
17
READ HEAD FOR RF IDENTICFICATION SYSTEMS
DTA101
1. Safety instructions
General
Follow the operating instructions. Non-observance of the instructions,
operation which is not in accordance with prescribed use, wrong installation or handling can affect the safety of people and machinery.
The installation and connection must comply with the applicable national and international standards. Responsibility lies with the person installing the unit.
The unit must be installed, connected and put into operation by a qualified electrician as the safe function of the unit and machinery is only guaranteed when installation is correctly carried out.
Disconnect the unit externally before handling it.
The unit must be supplied with an external direct voltage of 26.5…31.6 V according to the criteria for safe extra-low voltage (SELV).
According to the technical specifications indicated in the instructions the unit can
be operated in a wide operating temperature range. Because of the additional internal heating the housing walls can have high perceptible temperatures when
touched in hot environments.
In case of malfunction of the unit or uncertainties please contact the manufacturer.
Tampering with the unit can seriously affect the safety of people and machinery.
This is not permitted and leads to an exclusion of liability and warranty.
Radio equipment
Do not transport and store any flammable gases, liquids or explosive
substances near the unit. In general, radio equipment must not be used
in the vicinity of petrol stations, fuel depots, chemical plants or blasting operations.
Electronic devices
Operation of the unit can affect the function of electronic devices that
are not correctly shielded. Disconnect the unit in the vicinity of medical
equipment. Please contact the manufacturer of the corresponding device or equipment in case of problems.
ENGLISH
FCC Notices (USA, Canada)
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry
Canada. Operation is subject to the following two conditions.
(1) this device my not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
Warning: Changes or modifications made to this equipment not expressly approved by ifm electronic gmbh may void the FCC authorization to operate this
equipment.
11
READ HEAD FOR RF IDENTICFICATION SYSTEMS
DTA101
2. Function and features
• The DTA101 read head reads without contact data of RFID transponders
(ID tags) that conform to the system,
• converts them into digitally coded values
• and provides them to the AS-i control level
(AS-i master, controller or host).
Application examples:
• Material flow control in production lines
• Warehouse management by the automatic detection of stored products
• Tank management, order picking or product tracking
3. Operating principle
The ID tags are operated passively, i.e. without battery. The energy required for operation is supplied by the read head.
The physical principle of the energy transfer is based on inductive coupling. The
antenna coil integrated in the read head generates a magnetic field which partly
penetrates the antenna coil of the ID tag.
A voltage is generated by induction that supplies the data carrier with energy.
read
head DTA101
DTA101
Lesekopf
display
Anzeige
Impuls
pulse
antenna
Antenne
HFund
HF and
Analoganalogue
schaltung
circuit
ID tag
ID-TAG
energy
Energie
data
Daten
µController
µcontroller and
und
AS-interface
AS-interface
AS-i master,
Master,
AS-i
Controller
Host
controlleroder
or host
12
operating principle
READ HEAD FOR RF IDENTICFICATION SYSTEMS
DTA101
4. Indicators
LED
grün
green
gelb
yellow
rot
red
State
Meaning
green
ON
operating voltage ok
yellow
ON
tag read
red
ON
error AS-i data communication
operation and error display at the read head
5. Installation
Fixing is done using 2 M4 screws and nuts or an angle bracket. Information about
the available mounting accessories is given on our website at:
➔ Data sheet direct ➔ DTA101 ➔ Accessories
example
article no.
E20898
example
article no.
E20901
ENGLISH
www.ifm-electronic.com
mounting examples
When mounting several read heads adhere to the minimum distances between the
systems ➔ see 11. Technical data.
13
READ HEAD FOR RF IDENTICFICATION SYSTEMS
DTA101
6. Electrical connection
Connect the read head to the AS-i network using the M12 connector.
Voltage is supplied via the AS-i network.
You can find a selection of sockets on our website at:
www.ifm-electronic.com ➔ Data sheet direct ➔ DTA101 ➔ Accessories
1 BN
ASI+
3 BU
core colours of ifm sockets:
1 = BN (brown)
3 = BU (blue)
ASI
wiring
Adhere to the distance between the AS-i cable and the housing of the read head.
A = 100 mm
clear space read head ↔ cable
14
READ HEAD FOR RF IDENTICFICATION SYSTEMS
DTA101
7. The read head in the AS-i network
Basic setting
Parameters
Values
I/O code [hex]
ID code [hex]
Extended ID2 code [hex]
ID1 code for coded value [hex]
Slave address (factory setting)
Addressing
The read head is addressed using an addressing unit (e.g. AC1144), the master or
the AS-i software of the host (the components must support the AS-i version 2.1).
Assign an address between 1 and 31.
Analogue value representation
For the AS-interface the read head is a slave having an analogue input with the
transmission protocol to the profile 7.3. If the master operates to the master profile M3 or M4, it automatically detects the read head and supports the profile 7.3.
Assignment of the data bits
In one transmission cycle the following data are transferred in data triples.
E3
E2
E1 D16 D15 D14 D13 D12 D11 D10 D9
extension
Extention
bits
Bits
(static 0)0)
(statisch
D8
D7
D6
D5
D4
D3
D2
D1
User
Data
Bits
user
data
bits
Additional information bits:
O = overflow bit (is set for the values 7FFF and 8000 hex, otherwise 0)
V = valid bit (is set for a valid value)
ENGLISH
Coded value representation using the data bits D16...D1
The ID value is represented as a signed 16-bit number.
Range
Decimal
from
to
Hex
from
to
Value range
32767
7FFF
Message range
-1
-32768
FFFF
8000
Value 0 = no ID tag in the reading range or ID tag not detected.
15
READ HEAD FOR RF IDENTICFICATION SYSTEMS
DTA101
8. Approval of radio equipment
Marking to R & TTE (Radio and Telecommunications Terminal Equipment)
CE identification number: CE 0682
Intended use: use in all EU countries
9. EC Declaration of Conformity
You can find the EC declaration of conformity on our website at:
www.ifm-electronic.com
➔ Data sheet direct ➔ DTA101 ➔ Additional Data
10. Maintenance, repair, disposal
In case of correct use no maintenance and repair measures are necessary. Only the
manufacturer is allowed to repair the unit.
After use dispose of the unit in an environmentally friendly way in accordance
with the applicable national regulations.
16
READ HEAD FOR RF IDENTICFICATION SYSTEMS
DTA101
11. Technical data
DTA101
Read head DTS/125/RO/AS/US
with integrated AS-i slave
profile 7.3
rotatable M12 connector
1: integrated antenna , 2: tag positioning mark (middle of the antenna)
Application
Detection of objects on conveying systems;
suitable for travel speeds up to 0.5 m/s
AS-i
Electrical design
Operating voltage
Current consumption
Operating frequency
Travel speed *
[V]
[mA]
[kHz]
[m/s]
26.5...31.6 DC (AS-i)
” 50
125
” 0.5
Distance to the ID tag *
[mm]
” 15 (at 0.5 m/s); ” 20 (static)
Separation between read/read
heads
[mm]
Separation between read/write
heads**
[mm]
[ms]
Value range
Operating conditions
Protection
AS-i profile
I/O configuration
ID code
AS-i certificate
EMC
Housing material
Display
• 400 (at 0.5 m/s)
” 70
16 bits (15-bit ID value, 1-bit message)
operating temperature: -20...50 °C
storage temperature: -25....80 °C
vibration: 20 g; 10...2000 Hz
shock: 50 g; 11 ms
[Hex]
[Hex]
Connection
Remarks
ifm electronic gmbh • Teichstraße 4 • D-45127 Essen
IP 67, III
7.3
71502
EN 50295 (1999-03)
PA (polyamide)
3 LED
green: operating voltage
yellow: tag read
red: error AS-i data communication
ENGLISH
Data provision time
• 200 (at 0.5 m/s)
M12 connector
*) referred to the ID tag E80301 (middle of the screw)
For the distances to other ID tags see the respective data sheet (E803xx)
**) referred to the read/write head DTA100
We reserve the right to make technical alterations without prior notice .
GB - DTA101
17.03.2006
17
TÊTE DE LECTURE POUR IDENTIFICATION PAR RADIOFRÉQUENCE (RFID)
DTA101
La notice d'utilisation
... s'applique à tous les appareils de type DTA101.
... s'adresse à des personnes compétentes selon les directives CEM et basse tension.
... fait partie de l'appareil. Elle fournit des indications sur l'utilisation correcte du
produit. Lisez-la avant l'utilisation afin de vous familiariser avec les conditions environnantes, l'installation et le fonctionnement. Respectez les consignes de sécurité.
Contenu
1. Consignes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 19
2. Caractéristiques et fonctionnement . . . . . . . . . . . . . . . . . . . . . . . . . page 20
3. Fonctionnement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 20
4. Eléments de visualisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 21
5. Montage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 21
6. Raccordement électrique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22
7. La tête de lecture dans le réseau AS-i
Réglage de base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adressage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Représentation des valeurs analogiques . . . . . . . . . . . . . . . . . . . . . .
Affectation des bits de données . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Représentation des valeurs codées par des bits de données D16…D1.
page
page
page
page
page
23
23
23
23
23
9. Homologation des équipements radio . . . . . . . . . . . . . . . . . . . . . . . page 24
10. Déclaration de Conformité CE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 24
11. Maintenance, réparation, élimination . . . . . . . . . . . . . . . . . . . . . . . . page 24
12. Données techniques
Dimension . . . . . . . . . . . . . . .
Vitesse de passage . . . . . . . . .
Distance du TAG . . . . . . . . . . .
Distance entre têtes de lecture .
18
page
page
page
page
25
25
25
25
TÊTE DE LECTURE POUR IDENTIFICATION PAR RADIOFRÉQUENCE (RFID)
DTA101
1. Consignes de sécurité
Généralité
Respectez les indications de la notice d'utilisation. Le non-respect des
consignes, l'emploi non conforme par rapport aux prescriptions, un
montage ou une manipulation incorrects peuvent porter atteinte à la sécurité des
personnes et des installations.
Le montage et le raccordement doivent être conformes aux normes nationales et
internationales en vigueur. La personne qui installe l'appareil en est responsable.
L'appareil doit être monté, raccordé et mis en service par un électricien qualifié car
seul un montage correct garantit le bon fonctionnement de l'appareil et de l'installation.
Mettre l'appareil hors tension avant de le manipuler.
L'appareil doit être alimenté en tension continue de 26,5 à 31,6 V selon les critères
de la basse tension de sécurité (TBTS).
L'appareil peut fonctionner dans une grande plage de températures ambiantes selon la spécification technique fournie dans la notice. En ambiance chaude, en raison de l'échauffement interne supplémentaire, les parois du boîtier peuvent monter à des températures importantes.
En cas de mauvais fonctionnement de l'appareil ou en cas de doute, veuillez
contacter le fabricant. Les interventions sur l'appareil peuvent avoir des conséquences graves pour la sécurité des personnes et des installations. Elles ne sont pas
autorisées et aboutissent à une exclusion de responsabilité et de garantie.
Equipements radio
Ne transportez et stockez pas de gaz, liquides inflammables ou de substances explosives près de l'appareil. En général, les équipements radio
ne doivent pas être utilisés à proximité de stations d'essence, de dépôts de carburants, d'usines chimiques ou de lieux où il existe des risques de détonation.
Appareils électroniques
L'emploi de l'appareil peut affecter le bon fonctionnement des appareils
électroniques qui ne sont pas correctement blindés. Mettez l'appareil
hors tension à proximité des équipements médicaux. En cas de problèmes, veuillez
contacter le fabricant de l'appareil ou de l'équipement correspondant.
Des informations correspondantes concernant cette homologation du matériel radio aux Etats-Unis / au Canada se trouvent dans la partie anglaise "1. Safety Instruction".
19
FRANÇAIS
Homologation FCC
TÊTE DE LECTURE POUR IDENTIFICATION PAR RADIOFRÉQUENCE (RFID)
DTA101
2. Caractéristiques et fonctionnement
• La tête de lecture DTA101 lit sans contact les données des étiquettes
électroniques RFID (TAG) qui sont compatibles avec le système,
• les convertit en valeurs codées numériquement
• et les met à la disposition du bus de communication AS-i (maître AS-i ,
passerelle AS-i vers un autre bus de terrain, système de commande).
Exemples d'applications :
• Contrôle du flux de manutention dans des lignes de production ;
• Gestion de magasin grâce à une détection automatique des produits stockés ;
• Gestion de cuves, préparation de commandes ou traçabilité des produits
fabriqués.
3. Fonctionnement
Les TAG sont passifs, l'énergie nécessaire à leur fonctionnement étant fournie par
la tête de lecture.
Le principe physique du transfert de l'énergie repose sur le couplage inductif. La
bobine de l'antenne intégrée dans la tête de lecture génère un champ magnétique
qui pénètre en partie la bobine de l'antenne du TAG.
Une tension est générée par induction qui alimente le support de données en
énergie.
DTA101
têteLesekopf
de lecture
DTA101
Anzeige
affichage
Impuls
impulsion
Antenne
antenne
HF- und
circuit
HF
Analoget
schaltung
analogique
ID-TAG
TAG
énergie
Energie
données
Daten
µController
µcontrôleur
und
et AS-interface
AS-interface
AS-i
Master,
maître
AS-i,
Controller
Host
système
de oder
commande
20
principe de fonctionnement
TÊTE DE LECTURE POUR IDENTIFICATION PAR RADIOFRÉQUENCE (RFID)
DTA101
4. Eléments de visualisation
grün
verte
gelb
jaune
rot
rouge
LED
Etat
verte
ALLUMEE
tension d'alimentation ok
jaune
ALLUMEE
étiquette lue
rouge ALLUMEE
Signification
erreur de communication des données AS-i
indication de fonctionnement
et d'erreurs sur la tête de lecture
5. Montage
La fixation se fait par 2 vis M4 et écrous ou par une équerre. Vous trouverez des
informations sur les accessoires de montage disponibles sur notre site web à :
www.ifm-electronic.com
➔ Fiche technique ➔ DTA101 ➔ Accessoires
exemple
référence
E20898
exemple
référence
E20901
En cas de montage de plusieurs têtes de lecture respectez les distances minimales
entre les systèmes ➔ voir 11. Données techniques.
21
FRANÇAIS
exemples de montage
TÊTE DE LECTURE POUR IDENTIFICATION PAR RADIOFRÉQUENCE (RFID)
DTA101
6. Raccordement électrique
Raccordez la tête de lecture au réseau AS-i via le connecteur M12. L'alimentation
en tension s'effectue via le réseau AS-i.
Vous trouvez une sélection de connecteurs femelles sur notre site web à :
www.ifm-electronic.com ➔ Fiche technique ➔ DTA101 ➔ Accessoires
1 BN
ASI+
3 BU
ASI
couleurs des fils conducteurs des
connecteurs femelles ifm :
1 = BN (brun)
3 = BU (bleu)
schéma de branchement
Respectez la distance entre le câble AS-i et le boîtier de la tête de lecture/d'écriture.
A = 100 mm
espace dégagé tête de lecture ↔ câble AS-i
22
TÊTE DE LECTURE POUR IDENTIFICATION PAR RADIOFRÉQUENCE (RFID)
DTA101
7. La tête de lecture dans le réseau AS-i
Réglages de base
Profil AS-i / Adresse
Valeurs
Code E/S [hexa]
Code ID [hexa]
Code ID2 [hexa]
Code ID1 [hexa]
Adresse d'esclave (réglage usine)
Adressage
La tête de lecture est adressée à l'aide d'une unité d'adressage (par ex. AC1144),
le maître AS-i ou le logiciel AS-i du système de commande (les composants doivent
être compatibles avec la version AS-i V 2.1).
Affectez une adresse entre 1 et 31.
Représentation des valeurs analogiques
La tête de lecture / écriture est considérée comme un esclave AS-i à une entrée
analogique utilisant le protocole de transmission suivant le profil AS-i 7.3. Si le
maître AS-i travaille selon le profil maître M3 ou M4, il détecte automatiquement
la tête de lecture et est compatible avec le profil 7.3.
Affectation des bits de données
Dans un cycle de transmission les données suivantes sont transmises par triplets de
données :
E3
E2
E1 D16 D15 D14 D13 D12 D11 D10 D9
bits
Extention
d'extension
Bits
(0
statique)
(statisch
0)
D8
D7
D6
D5
D4
D3
D2
D1
bits User
de données
Data Bitsutilisateurs
Bits d'information supplémentaires :
O = bit de débordement (est mis à 1 pour les valeurs 7FFF et 8000 hexa, sinon 0)
V = bit valable (est mis à 1 pour une valeur valable)
Représentation des valeurs stockées par des bits de données D16…D1
Plage
Décimal
de
à
Hexa
de
à
Plage de valeurs
32767
7FFF
Plage de messages
-1
-32768
FFFF
8000
FRANÇAIS
La valeur numérique stockée dans le TAG est représentée par un nombre de 16
bits avec signe.
Valeur 0 = aucun TAG dans la plage de lecture ou TAG non détecté.
23
TÊTE DE LECTURE POUR IDENTIFICATION PAR RADIOFRÉQUENCE (RFID)
DTA101
8. Homologation des équipements radio
Marquage selon R & TTE (Radio and Telecommunications Terminal Equipment =
équipements radioélectriques et équipements terminaux de télécommunications)
Numéro d'identification CE : CE 0682
Utilisation prévue : utilisation dans tous les états de l'UE
9. Déclaration de Conformité CE
Vous trouvez la déclaration de conformité CE sur notre site web à :
www.ifm-electronic.com ➔ Fiche technique ➔ DTA101 ➔ Information sur le Produit
10. Maintenance, réparation, élimination
En cas de fonctionnement correct, il n'est pas nécessaire de prendre des mesures
relatives à la maintenance et la réparation. L'appareil ne doit être réparé que par le
fabricant.
Assurez une élimination écologique de l'appareil après son usage selon les règlements nationaux en vigueur.
24
TÊTE DE LECTURE POUR IDENTIFICATION PAR RADIOFRÉQUENCE (RFID)
DTA101
11. Données techniques
DTA101
Tête de lecture RFID
DTS/125/RO/AS/US
avec esclave AS-i intégré
profil 7.3
connecteur M12 orientable
1: antenne intégrée, 2: repère TAG (milieu d'antenne)
Application
Détection d'objets sur des systèmes de convoyage ;
appropriée pour des vitesses de passage jusqu 'à 0,5 m/s
AS-i
Tension d'alimentation
[V]
Consommation
[mA]
Fréquence de fonctionnement [kHz]
Vitesse de passage *
[m/s]
Distance du TAG *
[mm]
Distance entre têtes de lecture [mm]
Distance entre têtes de
lecture/écriture**
[mm]
Temps de fourniture des données
[ms]
Plage de valeurs
Conditions d'utilisation
Protection
Profil AS-i
Configuration E/S
Code ID
Certificat AS-i
CEM
Matières boîtier
Indication
[hexa]
[hexa]
Raccordement
Remarques
ifm electronic gmbh • Teichstraße 4 • D-45127 Essen
26,5...31,6 DC (AS-i)
” 50
125
” 0.5
” 15 (à 0,5 m/s); ” 20 (statique)
• 200 (à 0,5 m/s)
• 400 (à 0,5 m/s)
” 70
16 bits (valeur ID de 15 bits + 1 bit de signe)
température ambiante : -20...50 °C
température de stockage : -25....80 °C
vibration : 20 g; 10...2000 Hz
choc : 50 g; 11 ms
IP 67, III
7.3
71502
EN 50295 (1999-03)
PA (polyamide)
3 LED
verte : tension d'alimentation
jaune : TAG lu
rouge : erreur de communication des données AS -i
FRANÇAIS
Technologie
embase M12
*) par rapport au TAG E80301 (milieu de la vis)
Pour les distances avec d'autres TAG voir la fiche technique correspondante
(E803xx)
**) par rapport à la tête de lecture/écriture DTA100
Nous nous réservons le droit de modifier les données techniques sans préavis .
FR - DTA101
17.03.2006
25
Technische Änderungen behalten wir uns ohne vorherige Ankündigung vor. • We reserve the right to make technical alterations without prior notice. • Nous nous réservons le droit de modifier les données techniques sans préavis.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2006:10:05 14:22:42
Producer                        : Acrobat Distiller 4.05 for Windows
Modify Date                     : 2006:10:05 14:23:46+02:00
Page Count                      : 26
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UN6DTS125-AA

Navigation menu